首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This review discusses the application of time-of-flight secondary ion mass spectrometry (TOF-SIMS) and magnetic sector SIMS with high lateral resolution performed on a Cameca NanoSIMS 50(L) to imaging lipids. The similarities between the two SIMS approaches and the differences that impart them with complementary strengths are described, and various strategies for sample preparation and to optimize the quality of the SIMS data are presented. Recent reports that demonstrate the new insight into lipid biochemistry that can be acquired with SIMS are also highlighted. This article is part of a Special Issue entitled Tools to study lipid functions.  相似文献   

2.

Background  

Analytical imaging by secondary ion mass spectrometry (SIMS) provides images representative of the distribution of a specific ion within a sample surface. For the last fifteen years, concerted collaborative research to design a new ion microprobe with high technical standards in both mass and lateral resolution as well as in sensitivity has led to the CAMECA NanoSims 50, recently introduced onto the market. This instrument has decisive capabilities, which allow biological applications of SIMS microscopy at a level previously inaccessible. Its potential is illustrated here by the demonstration of the specific affinity of a melanoma marker for melanin. This finding is of great importance for the diagnosis and/or treatment of malignant melanoma, a tumour whose worldwide incidence is continuously growing.  相似文献   

3.
We attempted to indicate the requirements for biomedical applications of SIMS microscopy. Sample preparation methodology should preserve both the structural and the chemical integrity of the tissue. Furthermore, it is often necessary to correlate ionic and light microscope images. This implies a common methodological approach to sample preparation for both microscopes. The use of low or high mass resolution depends on the elements studied and their concentrations. To improve the acquisition and processing of images, digital imaging systems have to be designed and require both ionic and optical image superimposition. However, the images do not accurately reflect element concentration; a relative quantitative approach is possible by measuring secondary ion beam intensity. Using an internal reference element (carbon) and standard curves the results are expressed in micrograms/mg of tissue. Despite their limited lateral resolution (0.5 microns) the actual SIMS microscopes are very suitable for the resolution of biomedical problems posed by action modes and drug localization in human pathology. SIMS microscopy should provide a new tool for metabolic radiotherapy by facilitating dose evaluation. The advent of high lateral resolution SIMS imaging (less than 0.1 microns) should open up new fields in biomedical investigation.  相似文献   

4.
Mass spectrometry imaging and profiling of individual cells and subcellular structures provide unique analytical capabilities for biological and biomedical research, including determination of the biochemical heterogeneity of cellular populations and intracellular localization of pharmaceuticals. Two mass spectrometry technologies-secondary ion mass spectrometry (SIMS) and matrix assisted laser desorption/ionization mass spectrometry (MALDI MS)-are most often used in micro-bioanalytical investigations. Recent advances in ion probe technologies have increased the dynamic range and sensitivity of analyte detection by SIMS, allowing two- and three-dimensional localization of analytes in a variety of cells. SIMS operating in the mass spectrometry imaging (MSI) mode can routinely reach spatial resolutions at the submicron level; therefore, it is frequently used in studies of the chemical composition of subcellular structures. MALDI MS offers a large mass range and high sensitivity of analyte detection. It has been successfully applied in a variety of single-cell and organelle profiling studies. Innovative instrumentation such as scanning microprobe MALDI and mass microscope spectrometers enables new subcellular MSI measurements. Other approaches for MS-based chemical imaging and profiling include those based on near-field laser ablation and inductively-coupled plasma MS analysis, which offer complementary capabilities for subcellular chemical imaging and profiling.  相似文献   

5.
The virtues and limitations of SIMS ion microscopy are compared with other spectroscopic techniques applicable to biological microanalysis, with a special emphasis on techniques for elemental localization in biological tissue (electron, X-ray, laser, nuclear, ion microprobes). Principal advantages of SIMS include high detection sensitivity, high depth resolution, isotope specificity, and possibilities for three-dimensional imaging. Current limitations, especially in comparison to X-ray microanalysis, center on lateral spatial resolution and quantification. Recent SIMS instrumentation advances involving field emission liquid metal ion sources and laser post-ionization will help to minimize these limitations in the future. The molecular surface analysis capabilities of static SIMS, especially with the new developments in commercial time-of-flight spectrometers, are promising for application to biomimetic, biomaterials, and biological tissue or cell surfaces. However, the direct microchemical imaging of biomolecules in tissue samples using SIMS will be hindered by limited concentrations, small analytical volumes, and the inefficiencies of converting surface molecules to structurally significant gas phase ions. Indirect detection using elemental or isotopically tagged molecules, however, shows considerable promise for molecular imaging studies using SIMS ion microscopy.  相似文献   

6.
Biological imaging techniques are the most efficient way to locally measure the variation of different parameters on tissue sections. These analyses are gaining increasing interest since 20 years and allow observing extremely complex biological phenomena at lower and lower time and resolution scale. Nevertheless, most of them only target very few compounds of interest, which are chosen a priori, due to their low resolution power and sensitivity. New chemical imaging technique has to be introduced in order to overcome these limitations, leading to more informative and sensitive analyses for biologists and physicians.Two major mass spectrometry methods can be efficiently used to generate the distribution of biological compounds over a tissue section. Matrix-Assisted Laser Desorption/Ionisation-Mass Spectrometry (MALDI-MS) needs the co-crystallization of the sample with a matrix before to be irradiated by a laser, whereas the analyte is directly desorbed by a primary ion bombardment for Secondary Ion Mass Spectrometry (SIMS) experiments. In both cases, energy used for desorption/ionization is locally deposited -some tens of microns for the laser and some hundreds of nanometers for the ion beam- meaning that small areas over the surface sample can be separately analyzed. Step by step analysis allows spectrum acquisitions over the tissue sections and the data are treated by modern informatics software in order to create ion density maps, i.e., the intensity plot of one specific ion versus the (x,y) position.Main advantages of SIMS and MALDI compared to other chemical imaging techniques lie in the simultaneous acquisition of a large number of biological compounds in mixture with an excellent sensitivity obtained by Time-of-Flight (ToF) mass analyzer. Moreover, data treatment is done a posteriori, due to the fact that no compound is selectively marked, and let us access to the localization of different lipid classes in only one complete acquisition.  相似文献   

7.
High resolution imaging by organic secondary ion mass spectrometry   总被引:1,自引:0,他引:1  
Secondary-ion mass spectrometry (SIMS) is based on the acceleration of high-energy primary ions onto a target. Secondary electrons, neutrals and ions are emitted from the target, reflecting its chemical composition. This enables simultaneous analysis and localization of target molecules, giving valuable information that is difficult or impossible to obtain with other analytical methods. The secondary ions can be extracted and detected by any type of mass analyzer. SIMS is unique in its ability to detect several target molecules simultaneously in small samples and to image their localization at subcellular resolution. The recent development of bioimaging SIMS opens up new possibilities in biotechnology and biological research with applications in biomedicine and pathology. The current development of this technique has the potential to become as important for biotechnology as the advent of the electron microscope, confocal microscope or in situ hybridization.  相似文献   

8.
Dynamic secondary ion mass spectrometry (SIMS) has been utilised to study the post-mortem distribution of aluminium in air-dried frozen sections from unfixed, unstained human brain in order to minimise contamination of the tissue and avoid redistribution and extraction of endogenous tissue aluminium. Substrates, sputter-coated with silver, were found to be free of focal aluminum surface contamination and thus minimised substrate induced artefacts in the tissue aluminium ion image. SIMS imaging of aluminium secondary ions at a mass resolution that eliminated the major molecular interferences, combined with a photomontage technique provided a unique strategy for studying aluminium distribution in tissue unrivalled by other spatially resolved microanalytical techniques such as laser microprobe mass spectrometry or X-ray microanalysis. Using this strategy, high densities of focal aluminium accumulations have been demonstrated in the cerebral cortex of the majority of chronic renal dialysis patients studied. In contrast, such aluminium accumulations were absent in control patients. SIMS imaging of aluminium appeared to provide much better discrimination between the dialysis patient group and the control group than one of the most widely used techniques for measuring aluminium in bulk samples, graphite furnace atomic absorption spectrometry. Preliminary studies have shown the feasibility of quantifying focal aluminium SIMS images obtained from brain tissue using aluminium-loaded brain homogenates as reference standards.  相似文献   

9.
超高分辨率显微镜成像技术与同位素示踪技术相结合的纳米二次离子质谱技术(NanoSIMS)具有较高的灵敏度和离子传输效率、极高的质量分辨率和空间分辨率(< 50 nm),代表着当今离子探针成像技术的最高水平.利用稳定性或者放射性同位素在原位或者微宇宙条件下示踪目标微生物,然后将样品进行固定、脱水、树脂包埋或者导电镀膜处理,制备成可供二次离子质谱分析的薄片,进一步通过NanoSIMS成像分析,不仅能够在单细胞水平上提供微生物的生理生态特征信息,而且能够准确识别复杂环境样品中的代谢活跃的微生物细胞及其系统分类信息,对于认识微生物介导的元素生物地球化学循环机制具有重要意义.介绍了纳米二次离子质谱技术的工作原理和技术路线,及其与同位素示踪技术、透射电子显微镜(TEM)、扫描电子显微镜(SEM)、荧光原位杂交技术(FISH)、催化报告沉积荧光原位杂交技术(CARD-FISH)、卤素原位杂交技术(Halogen In Situ Hybridization,HISH)等联合使用在微生物生态学研究方面的应用.  相似文献   

10.
Secondary ion mass spectrometry (SIMS) microscopy, a mass spectrometry method designed in the 1960s, offers new analytical capabilities, high sensitivity (ppm to ppb region), high specificity and improved lateral resolution, thus facilitating insight into many physiological and biomedical questions. Apart from the sample preparation and the physical characteristics of the detection, the biological model must also be considered. SIMS analysis of diffusible ions and molecules requires strict cryogenic procedures which always begin by a flash-freeze fixation. Cellular integrity can be checked by mapping the major element distributions since intra and extracellular ions are redistributed only in damaged cells. Cryofixing may be followed either by a freeze-fracture methodology or by cryoembedding and dry-cutting. Chemical sample preparation is only used for ions or molecules bound to fixed cell structures. The use of scanning procedures ameliorates the lateral resolution and chromosome imaging has been reported with probe size of below 50nm. Absolute quantification can be derived for embedded specimen by using internal references included in tissue equivalent resins. The sensitivity is limited by the ionization yield of the tag element and may be further impaired when working at high mass resolution (≥5000) to eliminate interfering cluster ions. SIMS drug mapping is usually performed after in vitro administration of a molecule to cell culture systems. Drug detection is accomplished indirectly by detecting a tag isotope naturally present or introduced by labelling, mainly with halogens,15N and14C. Molecular imaging with TOF-SIMS is an appealing alternative especially for heavier compounds. We stress some biological problems through a critical review of published SIMS drug studies. SIMS proved useful in assessing the targeting specificity of nuclear medicine pharmaceutics, even after in vivo administration. The first microscopic evidence of a thionamide induced follicular blockade of the iodine organification process is presented in a human sample.  相似文献   

11.
From a variety of analytical electron microscopy experiments, the chromosomes of dinoflagellates are known to contain sizeable amounts of cations, the latter thought to contribute to the neutralization of the negative charge carried by the phosphate groups in the DNA backbone. From previous Ca and Mg chelation experiments, it is also known that these cations are necessary for the compaction and preservation of the chromosome architecture. Similar conclusions have been recently presented by our group concerning mammalian mitotic chromosomes, in studies based on secondary ion mass spectrometry (SIMS) carried out with the University of Chicago high-resolution scanning ion microprobe (UC-SIM). We have now applied this instrument to image the distribution of DNA-bound Ca(2+) and Mg(2+) in dinoflagellate chromosomes, a goal that could not be attained earlier by analytical electron microscopy. Analyzed quantitatively and imaged here by SIMS for the first time, through their cation content, are the chromosomes of the dinoflagellates Prorocentrum micans, Gymnodinium mikimotoi and Gymnodinium dorsum. The cell nuclei were isolated and prepared for SIMS analysis with a minimal protocol (mechanical fractionation in culture medium followed by ethanol drying), which did not expose the samples to artifact-creating, alien chemical agents. By this approach, we have confirmed the earlier findings by several authors, and contributed new structural information provided by our ion probe capability to erode the sample surface layer by layer (SIMS tomography). Dinoflagellates, due to the absence of histones, represent an ideal model system where cations may bind directly with DNA, allowing comparisons to be made with recently reported X-ray crystallography results at atomic resolution. Such comparisons yielded quantitative confirmation that the Ca(2+)+Mg(2+) concentrations found for e.g. P. micans are consistent with those anticipated to provide complete charge neutralization of naked DNA by cations, also resulting in maximal DNA compaction.  相似文献   

12.
Analytical imaging by secondary ion mass spectrometry (SIMS) using a state-of-the-art scanning ion microprobe enables the detection and mapping of tracer isotopes in human metaphase chromosomes. The stimulated mitosis of cells cultured in media containing labelled nucleosides, typically 14C-labelled thymidine or adenosine, and BrDU, yields chromosomes that have incorporated the labelled molecule in their constituent DNA. The label is subsequently detected and localized by SIMS imaging. The relative label signal intensities of sister chromatids can be quantified. The occurrence of sister chromatid exchanges (SCE) can be detected. The distribution of specific nucleosides can be directly mapped. This is non-uniform along the chromatids, giving rise to characteristic banding patterns (SIMS bands) that seem to correspond to the well known G- or Q-bands resulting from conventional staining methods. The study of a number of cytogenetic problems is expected to benefit from the use of this new method of approach, similar in principle, but potentially more sensitive and capable of higher spatial resolution than autoradiography.  相似文献   

13.
Isotope ratio determination in boron analysis   总被引:1,自引:0,他引:1  
Traditionally, boron (B) isotope ratios have been determined using thermal ionization mass spectrometry (TIMS) and, to some extent, secondary ion mass spectrometry (SIMS). Both TIMS and SIMS use a high-resolution mass analyzer, but differ in analyte ionization methods. TIMS uses electrons from a hot filament, whereas SIMS employs an energetic primary ion beam of Ga+, Cs+, or O- for analyte ionization. TIMS can be used in negative or positive ion modes with high sensitivity and precision of B isotope ratio determination. However, isobaric interferences may be a problem, if the sample is not well purified and/or memory of the previous sample is not removed. Time-consuming sample preparation, analyte (B) purification, and sample determination processes limit the applications of TIMS for routine analyses. SIMS can determine B and its isotope ratio in intact solid samples without destroying them, but has poorer resolution and sensitivity than TIMS, and is difficult to standardize for biological samples. Development of plasma-source mass spectrometry (MS) enabled the determination of B concentration and isotope ratio without requiring sample purification. Commonly used plasma-source MS uses an Ar inductively coupled plasma (ICP) as an ionization device interfaced to a low-resolution quadrupole mass analyzer. The quadrupole ICP-MS is less precise than TIMS and SIMS, but is a popular method for B isotope ratio determination because of its speed and convenience. B determination by ICP-MS suffers no spectroscopic interferences. However, sample matrices, memory effects, and some instrument parameters may affect the accuracy and precision of B isotope ratio determination if adequate precautions are not taken. New generations of plasma-source MS instruments using high-resolution mass analyzers provide better sensitivity and precision than the currently used quadrupole ICP-MS. Because of the convenience and high sample throughput, the high-resolution ICP-MS is expected to be the method of choice for B isotope ratio determination. The current state of instrumental capabilities is adequate for B isotope determination. However, precision and accuracy are primarily limited by sample preparation, introduction, and analytical methodology, including 1. Analyte loss and isotope fractionation during sample preparation. 2. The precision of B isotope determination in small samples, especially those containing low concentrations. 3. Difficult matrices. 4. Memory effects. Sample preparation by alkali fusion allows rapid and complete decomposition of hard-to-digest samples, but high-salt environments of the fused materials require extensive sample purification for B ratio determination. The alternative wet-ashing sample decomposition with HF also results in B loss and isotopic fractionation owing to the high volatility of BF3. Open-vessel dry- or wet-ashing methods usually do not work well for animal samples, and are also prone to B loss and contamination. Closed-vessel microwave digestion overcomes these problems, but the digests of biological materials have high C contents, which cause spectral interference on 11B and affect 11B/10B ratios. Exchange separation/preconcentration of B using exchange (cation or anion exchange, B-specific resin, e.g., Amberlite IRA-743) tend to cause B isotope fractionation, and C eluting from these resin columns may interfere with B isotope ratio determination. Memory effects of B that occur during sample determination may cause serious errors in B isotope ratio determination, especially when samples varying in B concentrations and/or isotope composition are analyzed together. Although the utilization of high-resolution plasma-source MS will undoubtedly improve analytical precision, it is the sample preparation, sample introduction, and analytical methodology that represent the primary limitation to accurate and precise B isotope ratio determination.  相似文献   

14.
Human striated muscle samples, from male control and Duchenne muscular dystrophy-affected children, were subjected to cluster-time-of-flight secondary ion mass spectrometry (cluster-ToF-SIMS) imaging using a 25 keV Bi(3)(+) liquid metal ion gun under static SIMS conditions. Spectra and ion density maps, or secondary ion images, were acquired in both positive and negative ion mode over several areas of 500 x 500 microm(2) (image resolution, 256 x 256 pixels). Characteristic distributions of various lipids were observed. Vitamin E and phosphatidylinositols were found to concentrate within the cells, whereas intact phosphocholines accumulated over the most damaged areas of the dystrophic muscles, together with cholesterol and sphingomyelin species. Fatty acyl chain composition varied depending on the region, allowing estimation of the local damage extent.  相似文献   

15.
Fundamental advances in secondary ion mass spectrometry (SIMS) now allow for the examination and characterization of lipids directly from biological materials. The successful application of SIMS-based imaging in the investigation of lipids directly from tissue and cells are demonstrated. Common complications and technical pitfalls are discussed. In this review, we examine the use of cluster ion sources and cryogenically compatible sample handling for improved ion yields and to expand the application potential of SIMS. Methodological improvements, including pre-treating the sample to improve ion yields and protocol development for 3-dimensional analyses (i.e. molecular depth profiling), are also included in this discussion. New high performance SIMS instruments showcasing the most advanced instrumental developments, including tandem MS capabilities and continuous ion beam compatibility, are described and the future direction for SIMS in lipid imaging is evaluated.  相似文献   

16.
Taking advantage of the sensitivity, the lateral resolution and the ability of secondary ion mass spectrometry (SIMS) for elemental imaging, we have shown that the main alkaline and alkaline-earth cations exhibited clear-cut regionalization in flax seeds. Calcium, and even more magnesium were almost exclusively located within the protein bodies (PBs); and they were practically absent from the tissue areas with no PBs, such as the provascular tissue. By contrast, sodium was almost exclusively located outside the PBs; moreover, most of the seed sodium was in the tissues at the seed periphery (chiefly the teguments). Among the studied cations, potassium was the only one with a non-negligible concentration both in and outside the PBs.  相似文献   

17.
New generations of analytical techniques for imaging of metals are pushing hitherto boundaries of spatial resolution and quantitative analysis in biology. Because of this, the application of these imaging techniques described herein to the study of the organization and dynamics of metal cations and metal-containing biomolecules in biological cell and tissue is becoming an important issue in biomedical research. In the current review, three common metal imaging techniques in biomedical research are introduced, including synchrotron X-ray fluorescence (SXRF) microscopy, secondary ion mass spectrometry (SIMS), and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). These are exemplified by a demonstration of the dopamine-Fe complexes, by assessment of boron distribution in a boron neutron capture therapy cell model, by mapping Cu and Zn in human brain cancer and a rat brain tumor model, and by the analysis of metal topography within neuromelanin. These studies have provided solid evidence that demonstrates that the sensitivity, spatial resolution, specificity, and quantification ability of metal imaging techniques is suitable and highly desirable for biomedical research. Moreover, these novel studies on the nanometre scale (e.g., of individual single cells or cell organelles) will lead to a better understanding of metal processes in cells and tissues.  相似文献   

18.
This review describes the current state of mass spectrometry imaging (MSI) in life sciences. A brief overview of mass spectrometry principles is presented followed by a thorough introduction to the MSI workflows, principles and areas of application. Three major desorption-ionization techniques used in MSI, namely, secondary ion mass spectrometry (SIMS), matrix-assisted laser desorption ionization (MALDI), and desorption electrospray ionization (DESI) are described, and biomedical and life science imaging applications of each ionization technique are reviewed. A separate section is devoted to data handling and current challenges and future perspectives are briefly discussed at the end.  相似文献   

19.
Cholesterol is believed to be an important component in compositionally distinct lipid domains in the cellular plasma membrane, which are referred to as lipid rafts. Insight into how cholesterol influences the interactions that contribute to plasma membrane organization can be acquired from model lipid membranes. Here we characterize the lipid mixing and phase behavior exhibited by (15)N-dilaurolyphosphatidycholine ((15)N-DLPC)/deuterated distearoylphosphatiylcholine (D(70)-DSPC) membranes with various amounts of cholesterol (0, 3, 7, 15 or 19mol%) at room temperature. The microstructures and compositions of individual membrane domains were determined by imaging the same membrane locations with both atomic force microscopy (AFM) and high-resolution secondary ion mass spectrometry (SIMS) performed with a Cameca NanoSIMS 50. As the cholesterol composition increased from 0 to 19mol%, the circular ordered domains became more elongated, and the amount of (15)N-DLPC in the gel-phase domains remained constant at 6-7mol%. Individual and micron-sized clusters of nanoscopic domains enriched in D(70)-DSPC were abundant in the 19mol% cholesterol membrane. AFM imaging showed that these lipid domains had irregular borders, indicating that they were gel-phase domains, and not non-ideally mixed lipid clusters or nanoscopic liquid-ordered domains.  相似文献   

20.
We report the use of a surface analysis approach, static secondary ion mass spectrometry (SIMS) equipped with a molecular (ReO(4)(-)) ion primary beam, to analyze the surface of intact microbial cells. SIMS spectra of 28 microorganisms were compared to fatty acid profiles determined by gas chromatographic analysis of transesterfied fatty acids extracted from the same organisms. The results indicate that surface bombardment using the molecular primary beam cleaved the ester linkage characteristic of bacteria at the glycerophosphate backbone of the phospholipid components of the cell membrane. This cleavage enables direct detection of the fatty acid conjugate base of intact microorganisms by static SIMS. The limit of detection for this approach is approximately 10(7) bacterial cells/cm(2). Multivariate statistical methods were applied in a graded approach to the SIMS microbial data. The results showed that the full data set could initially be statistically grouped based upon major differences in biochemical composition of the cell wall. The gram-positive bacteria were further statistically analyzed, followed by final analysis of a specific bacterial genus that was successfully grouped by species. Additionally, the use of SIMS to detect microbes on mineral surfaces is demonstrated by an analysis of Shewanella oneidensis on crushed hematite. The results of this study provide evidence for the potential of static SIMS to rapidly detect bacterial species based on ion fragments originating from cell membrane lipids directly from sample surfaces.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号