首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper presents an innovative portable chip-based RT–PCR system for amplification of specific nucleic acid and detection of RNA-based viruses. The miniature RT–PCR chip is fabricated using MEMS (Micro-electro-mechanical-system) techniques, and comprises a micro temperature control module and a PDMS (polydimethylsiloxane)-based microfluidic control module. The heating and sensing elements of temperature control module are both made of platinum and are located within the reaction chambers in order to generate a rapid and uniform thermal cycling. The microfluidic control module is capable of automating testing process with minimum human intervention. In this paper, the proposed miniature RT–PCR system is used to amplify and detect two RNA-based viruses, namely dengue virus type-2 and enterovirus 71 (EV 71). The experimental data confirm the ability of the system to perform a two-step RT–PCR process. The developed miniature system provides a crucial tool for the diagnosis of RNA-based viruses.  相似文献   

2.
Miniature RT-PCR system for diagnosis of RNA-based viruses   总被引:1,自引:0,他引:1       下载免费PDF全文
This paper presents an innovative portable chip-based RT-PCR system for amplification of specific nucleic acid and detection of RNA-based viruses. The miniature RT-PCR chip is fabricated using MEMS (Micro-electro-mechanical-system) techniques, and comprises a micro temperature control module and a PDMS (polydimethylsiloxane)-based microfluidic control module. The heating and sensing elements of temperature control module are both made of platinum and are located within the reaction chambers in order to generate a rapid and uniform thermal cycling. The microfluidic control module is capable of automating testing process with minimum human intervention. In this paper, the proposed miniature RT-PCR system is used to amplify and detect two RNA-based viruses, namely dengue virus type-2 and enterovirus 71 (EV 71). The experimental data confirm the ability of the system to perform a two-step RT-PCR process. The developed miniature system provides a crucial tool for the diagnosis of RNA-based viruses.  相似文献   

3.
We have developed a novel multisample detection system by employing a technology combining a tag insertion primer and an electrochemical DNA chip. In the first application, Helicobacter species-infected mouse samples were detected. The primers that insert a different tag sequence in each sample were prepared, and loop-mediated isothermal amplification (LAMP) reaction was carried out. Then amplification products in which a part of the sequence was different in each sample could be obtained. The target sample in which these amplification products were mixed was injected into a cassette that included the DNA chip with immobilized probes. After the cassette was set in the DNA detection system, Genelyzer, the processes of hybridization, washing, and detection were performed by the system automatically. The positive and negative concordance rates of the existing nested polymerase chain reaction (PCR) method and this method were 100% (40/40 samples) and 97.3% (117/120 samples), respectively. This is a simple high-throughput method. Moreover, the cost per sample can be drastically lowered. Therefore, it is expected to contribute to the diagnosis of infectious agents in humans and animals.  相似文献   

4.
在精准医疗、个性化医疗的大背景下,分子诊断在病原体检测、肿瘤诊断、优生优育、环境保护、食品安全等领域的应用越来越广泛,并逐渐向操作简单、快速准确、低成本、适用于基层及家庭使用的分子即时检测(point-of-care testing,POCT)方向发展。超快脉冲控制PCR(ultra-fast pulse-controlled PCR,upPCR)是实时荧光定量PCR(qPCR)技术的延伸和升级,该技术利用能量脉冲控制扩增反应中的金属加热元件(主要是纳米金),在几百微秒内完成溶液局部微环境的快速升温,实现模板DNA的解链变性,停止加热后反应微环境可被周围溶液快速冷却到聚合酶的延伸温度,实现引物退火和模板DNA的扩增,单个变性-扩增循环仅有1.5~5 s,远快于传统PCR(约90 s/循环),从而能够极大地加快扩增反应速度。upPCR技术在保留了传统qPCR高灵敏度、高特异性和多重检测等优势的基础上,增加了超快速(低于15 min)、设备简单等新优势,非常适合用于基层检测等分子POCT场景。本文主要对upPCR技术的原理、设备、核心原料及在分子诊断中的应用进行综述,并对该技术存在的优缺点,以及未来的技术发展和应用趋势进行了讨论。  相似文献   

5.

Background

Polymerase chain reaction (PCR) is used in nucleic acid tests of infectious diseases in point-of-care testing. Previous studies have demonstrated real-time PCR that uses a micro-PCR chip made of packing tape, double-sided tape, and a plastic cover with polycarbonate or polypropylene on a black matte printed circuit board substrate. Despite the success of DNA amplification and fluorescence detection using an early version of the micro-PCR chip, reaching the target temperature was fairly slow and, as a result, the total running time was getting longer. To reduce this runtime, the micro-PCR chip was modified by reducing the heater pattern size of the PCB substrate to one-quarter of the original size or less, while maintaining the ability of the heating pattern to cover the reservoir area of the microfluidic channel. In subsequent experiments, DNA amplification failed several times. During the analysis of the cause of this failure, it was found that the reagent was boiling with the heating range from 25 to 95 °C.

Methods

As a method of DNA amplification verification, images were captured by digital single-lens reflex camera to detect FAM fluorescence using diagonal illumination from a blue LED light source. The images were automatically captured at 72 °C (the extension step in nucleic acid amplification) and the brightness of the captured images was analyzed to con-firm the success of DNA amplification.

Results

Compared to the previous chip with a larger heating pattern size, the current chip appears to generate excess energy as the size of the heating pattern was reduced. To reduce this excess energy, the initial voltage was lowered to 2 V and 2.5 V, which is equivalent to a one-fifth and one-quarter voltage–power reduction in pulse width modulation control, respectively. In both voltage reduction cases, the DNA amplification was successful.

Conclusions

DNA amplification tests may fail due to the excess energy generated by reducing the heater pattern size of the PCB substrate. However, the tests succeeded when the voltage was reduced to 2 V or 2.5 V. The 2.5 V power test was more efficient for reducing the overall running time.
  相似文献   

6.
DNA analysis with multiplex microarray-enhanced PCR   总被引:3,自引:2,他引:1       下载免费PDF全文
We have developed a highly sensitive method for DNA analysis on 3D gel element microarrays, a technique we call multiplex microarray-enhanced PCR (MME-PCR). Two amplification strategies are carried out simultaneously in the reaction chamber: on or within gel elements, and in bulk solution over the gel element array. MME-PCR is initiated by multiple complex primers containing gene-specific, forward and reverse, sequences appended to the 3′ end of a universal amplification primer. The complex primer pair is covalently tethered through its 5′ end to the polyacryl- amide backbone. In the bulk solution above the gel element array, a single pair of unattached universal primers simultaneously directs pseudo-monoplex PCR of all targets according to normal solution-phase PCR. The presence of a single universal PCR primer pair in solution accelerates amplification within gel elements and eliminates the problem of primer interference that is common to conventional multiplex PCR. We show 106-fold amplification of targeted DNA after 50 cycles with average amplification efficiency 1.34 per cycle, and demonstrate specific on-chip amplification of six genes in Bacillus subtilis. All six genes were detected at 4.5 pg of bacterial genomic DNA (equivalent to 103 genomes) in 60 independent amplification reactions performed simultaneously in single reaction chamber.  相似文献   

7.
We have devised a sensitive and rapid method for the detection of several bacterial pathogens in clinical specimens using PCR. This method has been named Direct Labeling and Detection Procedure (DLDP) and is based on the direct incorporation of a nonradioactive digoxigenin label (DIG-11-dUTP) into a microbial species-specific gene fragment during amplification. Following amplification, the resulting PCR products are cleansed of nonincorporated DIG-11-dUTP, spotted onto a nylon membrane, fixed by UV-crosslinking and the labeled DNA is visualized by digoxigenin detection reagents. Using cultivated reference bacteria (Staphylococcus aureus, Streptococcus pneumoniae, Pseudomonas aeruginosa) we were able to demonstrate a rapid and sensitive detection of < 20 CFU of bacteria in human secretions (sputum, urine, mucous). The present study suggests that DLDP can be used as a reliable method for indication of bacteria in clinical or environmental specimens with the proviso that the selected corresponding oligonucleotide primers provide amplification of strong species-specific genes.  相似文献   

8.
环介导等温扩增核酸技术及其应用   总被引:17,自引:0,他引:17  
环介导等温扩增(loop-mediated isothermal amplification,简称LAMP)是利用4个特殊设计的引物和具有链置换活性的DNA聚合酶,在恒温条件下特异、高效、快速地扩增DNA的新技术。该技术在1h内能扩增出109靶序列拷贝,扩增产物是一系列反向重复的靶序列构成的茎环结构和多环花椰菜样结构的DNA片段的混合物,电泳后在凝胶上显现出由不同大小的区带组成的阶梯式图谱。LAMP技术以其特异性强、灵敏度高、快速、准确和操作简便等优点在核酸的科学研究、疾病的诊断和转基因食品检测等领域得到了日益广泛的应用。  相似文献   

9.
We have applied an integrated circuit photodiode array (PDA) chip system to a DNA chip. The PDA chip system, constructed using conventional bipolar semiconductor technology, acts as a solid transducer surface as well as a two-dimensional photodetector. DNA hybridization was performed directly on the PDA chip. The target DNA, the Bacillus subtilis sspE gene, was amplified by polymerase chain reaction (PCR). The 340-bp PCR product was labeled using digoxigenin (DIG). A silicon nitride layer on the photodiode was treated with poly-L-lysine to immobilize the DNA on the surface of the photodiode detection elements. Consequently, the surface of the photodiode detector became positively charged. An anti-DIG-alkaline phosphatase conjugate was reacted with the hybridized DIG-labeled DNA. A color reaction was performed based on the enzymatic reaction between nitroblue tetrazolium/5-bromo-4-chloro-3-indolyl-phosphate (NBT/BCIP) staining solution and a DNA complex containing antibodies. A blue precipitate was formed on the surfaces of the photodiode detection elements. Successful quantitative analysis of the hybridized PCR products was achieved from the light absorption properties of the blue enzymatic reaction product that was produced after a series of reaction processes. Our DNA chip system avoids the complicated optical alignments and light-collecting optical components that are usually required for an optical DNA chip device. As a result, a simple, compact, portable and low-cost DNA chip is achieved. This system has great potential as an alternative system to the conventional DNA reader.  相似文献   

10.
Several existing molecular tests for multidrug-resistant tuberculosis (MDR-TB) are limited by complexity and cost, hindering their widespread application. The objective of this proof of concept study was to develop a simple Nucleic Acid Lateral Flow (NALF) immunoassay as a potential diagnostic alternative, to complement conventional PCR, for the rapid molecular detection of MDR-TB. The NALF device was designed using antibodies for the indirect detection of labeled PCR amplification products. Multiplex PCR was optimized to permit the simultaneous detection of the drug resistant determining mutations in the 81-bp hot spot region of the rpoB gene (rifampicin resistance), while semi-nested PCR was optimized for the S315T mutation detection in the katG gene (isoniazid resistance). The amplification process additionally targeted a conserved region of the genes as Mycobacterium tuberculosis (Mtb) DNA control. The optimized conditions were validated with the H37Rv wild-type (WT) Mtb isolate and Mtb isolates with known mutations (MT) within the rpoB and katG genes. Results indicate the correct identification of WT (drug susceptible) and MT (drug resistant) Mtb isolates, with the least limit of detection (LOD) being 104 genomic copies per PCR reaction. NALF is a simple, rapid and low-cost device suitable for low resource settings where conventional PCR is already employed on a regular basis. Moreover, the use of antibody-based NALF to target primer-labels, without the requirement for DNA hybridization, renders the device generic, which could easily be adapted for the molecular diagnosis of other infectious and non-infectious diseases requiring nucleic acid detection.  相似文献   

11.
A method was developed for the detection of Giardia cysts by using the polymerase chain reaction (PCR) and the giardin gene as the target. DNA amplification by PCR, using giardin DNA as the target, resulted in detection of both live and dead cysts. When giardin mRNA was used as the target, the ability to amplify cDNA by PCR depended on the mode of killing. Cysts killed by freezing were not detected by PCR when giardin mRNA was the target. Cysts killed by heating or exposure to monochloramine, however, gave positive detection signals for both DNA and giardin mRNA targets. The amount of giardin mRNA and total RNA was significantly increased in live cysts following the induction of excystation. Cysts killed by freezing, heating, or exposure to monochloramine did not show a change in RNA content. The detection of the giardin gene by PCR permits a sensitive and specific diagnosis for Giardia spp. Discrimination between live and dead cysts can be made by measuring the amounts of RNA or PCR-amplified product from the giardin mRNA target before and after the induction of excystation.  相似文献   

12.
A novel flow-through polymerase chain reaction (PCR) microfluidic system using vapor pressure was developed that can achieve ultra-rapid, small-volume DNA amplification on a chip. The 40-cycle amplification can be completed in as little as 120 s, making this device the fastest PCR system in the world. The chip device is made of a pressure-sensitive polyolefin (PSP) film and cyclo-olefin polymer (COP) substrate which was processed by cutting-work to fabricate the microchannel. The enclosed structure of the microchannel was fabricated solely by weighing the PSP film on the COP substrate, resulting in superior practical application. The vapor pressure in the denaturation zone of the destabilizing flow source was applied to the flow force, and ultra-rapid, efficient amplification was accomplished with a minimal amount of PCR reagents for detection. The flowing rhythm created by vapor pressure minimized the residual PCR products, leading to highly efficient amplification. For field test analysis, airborne dust was collected from a public place and tested for the presence of anthrax. The PCR chip had sufficient sensitivity for anthrax identification. The fastest time from aerosol sampling to detection was theoretically estimated as 8 min.  相似文献   

13.
目的:建立可准确、快速地鉴别诊断可感染人的不同属痘病毒的特异PCR方法。方法:设计针对正痘病毒属、副痘病毒属和传染性软疣病毒属的多对特异引物,并制备相应的DNA模板,针对不同的模板优化引物与反应条件,分别进行检测筛选,建立病毒属特异的单独与多重PCR方法。结果:单一模板的PCR扩增反应中,正痘病毒的检测敏感性可达101拷贝/μL(引物为OPEaL-F1880/OPEaL-R2057),副痘病毒的检测敏感性可达101拷贝/μL(引物为PP2/PP3),传染性软疣病毒的检测敏感性为100 pg/μL体系(引物为MCV1/MCV2);混合模板的PCR扩增反应中,各属特异的引物均可获得预期大小的特异片段。结论:我们建立的PCR诊断方法,可用于痘病毒科不同病毒属感染的实验室特异快速鉴别诊断。  相似文献   

14.
A method was developed for the detection of Giardia cysts by using the polymerase chain reaction (PCR) and the giardin gene as the target. DNA amplification by PCR, using giardin DNA as the target, resulted in detection of both live and dead cysts. When giardin mRNA was used as the target, the ability to amplify cDNA by PCR depended on the mode of killing. Cysts killed by freezing were not detected by PCR when giardin mRNA was the target. Cysts killed by heating or exposure to monochloramine, however, gave positive detection signals for both DNA and giardin mRNA targets. The amount of giardin mRNA and total RNA was significantly increased in live cysts following the induction of excystation. Cysts killed by freezing, heating, or exposure to monochloramine did not show a change in RNA content. The detection of the giardin gene by PCR permits a sensitive and specific diagnosis for Giardia spp. Discrimination between live and dead cysts can be made by measuring the amounts of RNA or PCR-amplified product from the giardin mRNA target before and after the induction of excystation.  相似文献   

15.
This study introduces a DNA microarray-based genotyping system for accessing single nucleotide polymorphisms (SNPs) directly from a genomic DNA sample. The described one-step approach combines multiplex amplification and allele-specific solid-phase PCR into an on-chip reaction platform. The multiplex amplification of genomic DNA and the genotyping reaction are both performed directly on the microarray in a single reaction. Oligonucleotides that interrogate single nucleotide positions within multiple genomic regions of interest are covalently tethered to a glass chip, allowing quick analysis of reaction products by fluorescence scanning. Due to a fourfold SNP detection approach employing simultaneous probing of sense and antisense strand information, genotypes can be automatically assigned and validated using a simple computer algorithm. We used the described procedure for parallel genotyping of 10 different polymorphisms in a single reaction and successfully analyzed more than 100 human DNA samples. More than 99% of genotype data were in agreement with data obtained in control experiments with allele-specific oligonucleotide hybridization and capillary sequencing. Our results suggest that this approach might constitute a powerful tool for the analysis of genetic variation.  相似文献   

16.
A novel method for DNA quantification and specific sequence detection in a highly integrated silicon microchamber array is described. Polymerase chain reaction (PCR) mixture of only 40 nL volume could be introduced precisely into each chamber of the mineral oil layer coated microarray by using a nanoliter dispensing system. The elimination of carry-over and cross-contamination between microchambers, and multiple DNA amplification and detection by TaqMan chemistry were demonstrated, for the first time, by using our system. Five different gene targets, related to Escherichia coli were amplified and detected simultaneously on the same chip by using DNA from three different serotypes as the templates. The conventional method of DNA quantification, which depends on the real-time monitoring of variations in fluorescence intensity, was not applied to our system, instead a simple method was established. Counting the number of the microchambers with a high fluorescence signal as a consequence of TaqMan PCR provided the precise quantification of trace amounts of DNA. The initial DNA concentration for Rhesus D (RhD) gene in each microchamber was ranged from 0.4 to 12 copies, and quantification was achieved by observing the changes in the released fluorescence signals of the microchambers on the chip. DNA target could be detected as small as 0.4 copies. The amplified DNA was detected with a CCD camera built-in to a fluorescence microscope, and also evaluated by a DNA microarray scanner with associated software. This simple method of counting the high fluorescence signal released in microchambers as a consequence of TaqMan PCR was further integrated with a portable miniaturized thermal cycler unit. Such a small device is surely a strong candidate for low-cost DNA amplification, and detected as little as 0.4 copies of target DNA.  相似文献   

17.
多重PCR技术研究进展   总被引:3,自引:1,他引:2  
多重PCR(Multiplex polymerase chain reaction,MPCR)是指通过一次PCR反应同时对多个靶标进行扩增,结合一定的检测手段对扩增产物进行检测从而实现对多个靶标进行诊断的技术。MPCR具有高效率、高通量、低成本的特性而被深入研究。目前MPCR技术已被广泛应用于科学研究和疾病诊断等领域,文中从MPCR扩增与检测两方面概述了MPCR技术发展及其应用,讨论了MPCR技术的优点及存在的问题,并且提出将反应体系分隔成小液滴或结合管式对流PCR(CapillaryconvectivePCR,CCPCR)技术的方式有望提高固相载体表面的扩增效率,从而开发出扩增效率高、一致性好、体系稳定、检测重数高的多重PCR技术。  相似文献   

18.
In this study, we describe a detection system for the indirect detection of vaccinia virus by DNA analysis. The system uses quartz crystal microbalance (QCM) as the detection technique and polymerase chain reaction (PCR) for amplification. Different immobilization strategies for the capture probe on the quartz chip are studied. For the QCM detection of hybridisation, the influence of the structure and length of target DNA is analyzed. For the detection of DNA from an amplification product, an efficient denaturation procedure is developed. On the basis of these investigations, vaccinia virus DNA is detected with only a low number of amplification rounds and a short analysis time. Specificity can be clearly shown. To enhance the signal strength and to have a further proof of specificity, a gold nanoparticle-tagged enhancer sequence can be used.  相似文献   

19.
20.
A microarray technique for the detection and identification of enteropathogenic bacteria at the species and subspecies levels was developed in this study, and the target bacteria included pathogenic Escherichia coli, Vibrio cholerae, Vibrio parahaemolyticus, Salmonella enterica, Campylobacter jejuni, Shigellae, Yersinia enterocolitica, and Listeria monocytogenes. The virulence gene of each pathogen was chosen as the amplification target, labeled with a fluorescence dye by multiplex polymerase chain reaction (PCR), and hybridized to the specific virulence gene probes that had been immobilized on a microchip. Stool specimens from 34 patients with diarrhea were tested in this study. Five were positive for multiple genera. Nested PCRs and sequencing were used to amplify and identify the related genes, which were found to share 95.8% to 100% of the nucleotide identity with the corresponding regions in the Genbank database. Real-time PCR was used to determine the number of gene copies to determine the sensitivity of this technique, which was shown to be 58 copies/microl. The results indicated that the microarray technique which targets multiple virulence genes of enteropathogenic bacteria at the species and subspecies levels is an attractive diagnostic tool for rapidly and simultaneously identifying multiple enteropathogenic pathogens in clinical practice, especially in patients with infectious diarrhea.  相似文献   