1.
An accurate and precise method was developed using HPLC-MS/MS to quantify erlotinib (OSI-774) and its O-desmethyl metabolite, OSI-420, in plasma. The advantages of this method include the use of a small sample volume, liquid-liquid extraction with high extraction efficiency and short chromatographic run times. The analytes were extracted from 100 microL plasma volume using hexane:ethyl acetate after midazolam was added to the sample for internal standardization. The compounds were separated on a Phenomenex C-18 Luna analytical column with acetonitrile:5 mM ammonium acetate as the mobile phase. All compounds were monitored by tandem mass spectrometry with electrospray positive ionization. The intra-day accuracy and precision (% coefficient of variation, % CV) estimates for erlotinib at 10 ng/mL were 90% and 9%, respectively. The intra-day accuracy and precision estimates for OSI-420 at 5 ng/mL were 80% and 4%, respectively. This method was used to quantify erlotinib and OSI-420 in plasma of patients (n=21) administered 150 mg erlotinib per day for non-small cell lung cancer.  相似文献   

2.
A new simple and rapid high-performance liquid chromatographic (HPLC) method with UV detection for the determination of indapamide in biological fluids has been developed. Indapamide and internal standard were isolated from serum and whole blood samples by solid-phase extraction with RP select B cartridges. The chromatographic separation was accomplished on a reversed-phase C(8) column with a mobile phase composed of 0.1% (v/v) triethylamine in water (pH 3.5) and acetonitrile (63:37, v/v). UV detection was set at 240 nm. The calibration curves were linear in the concentration range of 10.0-100.0 ng/ml for serum, and 50.0-500.0 ng/ml for whole blood, and the limits of quantification were 10.0 and 50.0 ng/ml, respectively.  相似文献   

3.
A new method was developed and validated for quantitating OSI-774 and its metabolite OSI-420 in human plasma. Sample preparation involved initial extraction with methyl t-butyl ether followed by back extraction with HCl and re-extraction with methyl t-butyl ether. This extraction process resulted in significant improvement in the specificity, reproducibility and sensitivity. The analytes were separated on a Water Symmetry C18 analytical column and the mobile phase consisted of acetonitrile-0.05 M potassium phosphate buffer (42:58, v/v) (pH 4.8), and monitored at a wavelength 345 nm. Values of between- and within-day precision and accuracy for both OSI-774 and OSI-420 were <20%. This method was successfully applied to study steady-state pharmacokinetics of OSI-774 and OSI-420 in a phase II clinical trial.  相似文献   

4.
A new simple and specific method was developed and validated for the quantitative determination of OSI-774 (Tarceva, Erlotinib) and its metabolite, OSI-420, in human plasma. Sample pretreatment involved a single protein precipitation step with acetonitrile. The analytes were separated on Waters X-Terra C(18) (50 x 2.1 mm I.D., 3.5 microm) analytical column and eluted with acetonitrile-water mobile (70:30, v/v) containing 0.1% formic acid. The analytes of interest were monitored by tandem mass spectrometry with electrospray positive ionization. The overall extraction efficiency was greater than 88% for OSI-774 and 62% for OSI-420, with values for within-day and between-day precision and accuracy of <15%. Compared to previous assays, this method is simple, specific, and reproducible and will be used to characterize the plasma pharmacokinetics of OSI-774 at doses of 50 to 150 mg to optimize treatment with this agent.  相似文献   

5.
A bioanalytical method for the determination of piperaquine in 100 microL blood applied onto sampling paper, by solid-phase extraction and liquid chromatography, has been developed and validated. Blood spots were cut into small pieces prior to addition of 0.3M perchloric acid, acetonitrile and phosphate buffer containing an internal standard. The liquid phase was loaded onto a mixed phase cation-exchange (MPC) solid-phase extraction column. Piperaquine and the internal standard were analysed by liquid chromatography and separated on a Chromolith Performance (100 mm x 4.6 mm) column with acetonitrile:phosphate buffer pH 2.5, I = 0.1 (8:92, v/v) at the flow of 3.5 mL/min. The UV detection was performed at 345 nm. The intra-assay precision was 12.0% at 0.150 microM, 7.3% at 1.25 microM and 7.3% at 2.25 microM. The inter-assay precision was 1.8% at 0.150 microM, 5.2% at 1.25 microM and 2.8% at 2.25 microM. The lower limit of quantification (LLOQ) was determined to 0.050 microM where the precision was 14.7%.  相似文献   

6.
A HPLC method with UV detection was developed and validated for the determination of thiorphan in human plasma. Nevirapine was used as the internal standard. Separation was performed by a Waters sunfire C18 reversed-phase column maintained at 35 degrees C. The mobile phase was a mixture of 0.05 M phosphate buffer with the pH adjusted to 2.6 and acetonitrile (74:26, v/v) at a flow rate of 1.0 mL/min. The UV detector was set at 210 nm. An original pre-treatment of plasma samples was developed, based on solid-phase extraction (SPE) with solid-phase extraction cartridges (Oasis HLB 3 mL, 60 mg). The extraction recovery for plasma samples of thiorphan at 0.1, 0.4 and 2.0 microg/mL was 93.5%, 98.2% and 97.8%, respectively. The calibration curve was linear with the correlation coefficient (r) above 0.9998. Linearity was verified over the range of 0.05-4 microg/mL thiorphan in plasma. The limit of quantification (LOQ) is 0.05 microg/mL. The mean accuracy was 92.7-99.6%. The coefficient of variation (precision) in the within- and between-batch was 2.2-8.4% and 4.1-8.1%, respectively. This method is simple, economical and specific, and has been used successfully in a pharmacokinetic study of thiorphan.  相似文献   

7.
A stereoselective reversed-phase HPLC assay to determine S-(-) and R-(+) enantiomers of esmolol in human plasma was developed. The method involved liquid-liquid extraction of esmolol from human plasma, using S-(-)-propranolol as the internal standard, and employed 2,3,4,6-tetra-O-acetyl-beta-d-glucopyranosyl isothiocyanate as a pre-column chiral derivatization reagent. The derivatized products were separated on a 5-microm reversed-phase C18 column with a mixture of acetonitrile/0.02 mol/L phosphate buffer (pH 4.5) (55:45, v/v) as mobile phase. The detection of esmolol derivatives was made at lambda=224 nm with UV detector. The assay was linear from 0.035 to 12 microg/ml for each enantiomer. The analytical method afforded average recoveries of 94.8% and 95.5% for S-(-)- and R-(+)-esmolol, respectively. For each enantiomer, the limit of detection was 0.003 microg/ml and the limit of quantification for the method was 0.035 microg/ml (RSD<14%). The reproducibility of the assay was satisfactory.  相似文献   

8.
A high-performance liquid chromatographic (HPLC) method with fluorescence detection has been developed for the determination of rizatriptan in human plasma. Following a single-step liquid-liquid extraction with methyl tertiarybutyl ether, the analytes were separated using a mobile phase consisting of 0.05% (v/v) triethylamine in water (adjusting to pH 2.75 with 85% phosphoric acid) and acetonitrile (92:8, v/v). Fluorescence detection was performed at an excitation wavelength of 225nm and an emission wavelength of 360nm. The linearity for rizatriptan was within the concentration range of 0.5-50ng/ml. The intra- and inter-day precisions of the method were not more than 8.0%. The lower limit of quantification (LLOQ) was 0.5ng/ml for rizatriptan. The method was sensitive, simple and repeatable enough to be used in pharmacokinetic studies.  相似文献   

9.
A simple, sensitive and reproducible method was developed for the determination of lamotrigine in whole blood with on-line solid phase extraction followed by HPLC separation with UV detection. Whole blood samples were diluted 1:1 with water and then injected directly on a clean-up column dry-packed with 40microm C8 silica and separated on a C18 reversed-phase column (150x4.6mm) at room temperature. The extraction column was activated with methanol and conditioned with phosphate buffer of pH 4.5. Mobile phases consisted of phosphate buffer of pH 4.5 for the extraction column and of phosphate buffer of pH 4.5 - acetonitrile (60:40, v/v) for the analytical column. At a flow rate of 1.0ml/min and a connection time of 1.0min, the complete cycle time was 10.0min. Detection was carried out at 260nm. No internal standard was necessary. The method was linear over concentration range 0.2-20.0microg/ml for lamotrigine. Recovery was 98%. Within-day and between-day coefficients of variation ranged from 1.8 to 6.7%.  相似文献   

10.
Gefitinib and erlotinib are two oral tyrosine kinase inhibitors (TKI) approved for the treatment of advanced non-small cell lung cancer (NSCLC). Published methods for simultaneous analysis of erlotinib and gefitinib in plasma are exclusively based on mass spectrometry. The purpose of this study was to develop a simple and sensitive HPLC-UV method to simultaneously quantify these two TKI in plasma. Following liquid-liquid extraction, gefitinib, erlotinib and sorafenib (internal standard), were separated with gradient elution (on a C8+ Satisfaction(?) using a mobile phase of acetonitrile/20mM ammonium acetate pH 4.5). Samples were eluted at a flow rate of 0.4 ml/min throughout the 15-min run. Dual UV wavelength mode was used, with gefitinib and erlotinib monitored at 331 nm, and sorafenib at 249 nm. The calibration was linear in the range 20-1000 ng/ml and 80-4000 ng/ml for gefitinib and erlotinib, respectively. Inter- and intra-day imprecision were less than 7.2% and 7.6% for gefitinib and erlotinib, respectively. This analytical method was successfully applied to assess the steady state plasma exposure to these TKI in NSCLC patients. This simple, sensitive, accurate and cost-effective method can be used in routine clinical practice to monitor gefitinib or erlotinib concentrations in plasma from NSCLC patients.  相似文献   

11.
Achiral and chiral HPLC methods were developed for clinafloxacin, a quinolone antimicrobial agent. For achiral assay, analytes were isolated from plasma by precipitating plasma proteins. Separation was achieved on a C18 column using an isocratic eluent of ion pairing solution–acetonitrile (80:20, v/v) at 1.0 ml/min with UV detection at 340 nm. The ion pairing solution was 0.05 M citric acid, 1.15 mM tetrabutylammonium hydroxide and 0.1% ammonium perchlorate. Inter-assay accuracy was within 4.9% with an inter-assay precision of 3.7% over a quantitation range of 0.025 to 10.0 μg/ml. For chiral assay, analytes were isolated from plasma by solid-phase extraction. Separation was achieved on a Crownpak CR(+) column using an isocratic eluent of water–methanol (88:12, v/v) containing 0.1 mM decylamine at 1.0 ml/min with UV detection at 340 nm. Perchloric acid was added to adjust pH to 2. Inter-assay accuracy was within 3.5% with a inter-assay precision of 5.4% over a quantitation range of 0.040 to 2.5 μg/ml.  相似文献   

12.
A high-performance liquid chromatographic method has been developed for the determination of the new podophyllotoxin derivative NK 611 in plasma samples. A solid—liquid extraction procedure with C18 extraction columns was used for extraction of plasma samples containing NK 611. The adsorbed NK 611 was eluted from the extraction columns with methanol—acetonitrile (50:50, v/v). The elution liquid was injected into a reversed-phase system consisting of a Chrompack C18 column. The mobile phase was acetonitrile—20 mM phosphate buffer, pH 7 (30:70, v/v). The UV detection mode allows sensitive determination of NK 611 in plasma within phase I trials. The limit of detection was 10 ng/ml, the limit of quantitation 35 ng/ml (for 1 ml of extracted plasma and 20-μl injection volume). The calibration curve is linear within the concentration range 100–1000 ng/ml. The recovery of NK 611 from spiked plasma samples was approximately 80%.  相似文献   

13.
A fully automated semi-microbore high performance liquid chromatographic (HPLC) method with column-switching using UV detection was developed for the determination of glimepiride from human plasma samples. Plasma sample (900 microl) was deproteinated and extracted with ethanol and acetonitrile. The extract (70 microl) was directly injected into a Capcell Pak MF Ph-1 pre-column where the primary separation occurred to remove proteins and retain drugs using a mixture of acetonitrile and 10mM phosphate buffer (pH 2.18) (20:80, v/v). The analytes were transferred from the pre-column to an intermediate column using a switching valve and then subsequently separated on an analytical column and monitored with UV detection at 228 nm. Glimepiride was eluted with retention time 34.9 min without interference of endogenous substance from plasma. The limit of quantification (LOQ) was 10 ng/ml for glimepiride. The calibration curves were linear over the concentration range of 10-400 ng/ml (r(2) = 0.9997). Moreover, inter- and intra-day precisions of the method were less than 15% and accuracies were higher than 99%. The developed method was successfully applied for the quantification of glimepiride in human plasma and was used to support a human pharmacokinetic study following a single oral administration of 2 mg glimepiride.  相似文献   

14.
A novel high-performance liquid chromatography (HPLC) assay for the estimation of formoterol in urine samples was developed and validated. A solid phase extraction (SPE) using Oasis HLB was optimised to isolate formoterol from a urine matrix followed by HPLC with UV detection. This extraction procedure concentrated the final analyte forty times so that UV detection can be used to determine even a low concentration of formoterol in urine samples. The urinary assay was performed in accordance with FDA and ICH regulations for the validation of bioanalytical samples. The samples were injected onto a C18 Spherisorb (250 mm x 4.6 mm x 5 microm) analytical column maintained at 30 degrees C. The mobile phase consisted of 5 mM of potassium dihydrogen orthophosphate buffer (adjusted to pH 3 with ortho phosphoric acid):acetonitrile (ACN) (70:30, v/v), and the formoterol peak was detected at wavelength 214 nm. The extraction recovery of formoterol from the urine sample was >95%. The calibration curve was linear (r2=0.99) over formoterol concentrations ranging from 1.5 to 25 ng/mL (n=6). The method had an accuracy of >92% and intra and inter-day precision CV% of <3.9% and <2.2%, respectively, at three different concentrations low, medium and high (10, 15, 20 ng/mL). The limit of quantification (LOQ) for formoterol was found to be 1.50 ng/mL. The accuracy and precision at the LOQ level were 95% and %CV <3.7% (n=10), respectively. The method reported is simple, reliable, precise, and accurate and has the capacity to be used for determination of formoterol in urine samples.  相似文献   

15.
R(−)-Ondansetron and S(+)-ondansetron in human serum were resolved and quantified using a stereospecific HPLC method. Each enantiomer and the internal standard prazosin were isolated from serum using a solid-phase extraction procedure on a cyanopropyl column. Recoveries of 97, 96 and 88% were obtained for the R(−)-enantiomer, the S(+)-enantiomer, and the internal standard, respectively. A cellulose-based chiral analytical column (Chiralcel OD) was used with a mobile phase consisting of hexane—95% ethanol—2-propanol—acetonitrile (65:25:10:1, v/v). Linear calibration curves were obtained for each enantiomer in serum in the concentration range 10–200 ng/ml. The limit of quantitation of each enantiomer was 10 ng/ml. The detection limit for each enantiomer in serum using UV detection at 216 nm was 2.5 ng/ml (signal-to-noise ratio of 3).  相似文献   

16.
Abouthiouzine is a newly synthesized antithyroid agent with a proposed less adverse effects profile than other currently used drugs. A simple and rapid reversed phase high performance liquid chromatography assay was developed to determine the concentration of abouthiouzine in human plasma. The procedure involved extraction of the drug and propranolol (internal standard) from the plasma using ethylacetate. The extract was evaporated under nitrogen and the residue was constituted with the mobile phase and injected onto micro-Bondapack phenyl column (10 microm, 3.9 mm x 150 mm). The mobile phase consisted of 10 mM potassium dihydrogen phosphate buffer, acetonitrile, and methanol in the ratio of 60:25:15 (v/v/v, pH=3.0), which was delivered at a rate of 1.5 ml/min. Abouthiouzine and the internal standard were monitored using UV detection at 240 nm; the run time was less than 5 min. The detection limit of abouthiouzine is 0.5 microg/ml. The within- and between-day coefficients of variation were less than 7%. Our method has been successfully used to measure abouthiouzine plasma concentrations in a rabbit model following an intravenous administration of the drug.  相似文献   

17.
A HPLC method with UV detection has been developed for the simultaneous determination of levomepromazine, clozapine and their main metabolites: N-desmethyl-levomepromazine, levomepromazine sulphoxide, O-desmethyl-levomepromazine, N-desmethylclozapine and clozapine N-oxide. The analytes were separated on a C8 reversed-phase column using a mobile phase composed of acetonitrile and a pH 2.0, 34 mM phosphate buffer containing 0.3% triethylamine (29:71, v/v). Loxapine was used as the internal standard. A reliable biological sample pre-treatment procedure by means of solid-phase extraction on C1 cartridges was implemented, which allows to obtain good extraction yields (>91%) for all analytes and appropriate sample purification from endogenous interference. The method was validated in terms of extraction yield, precision and accuracy. These assays gave RSD% values for precision always lower than 4.9% and mean accuracy values higher than 92%. The method is suitable for the therapeutic drug monitoring (TDM) of patients undergoing polypharmacy with levomepromazine and clozapine.  相似文献   

18.
A new microscale method is reported for the determination of doxorubicin and its active metabolite, doxorubicinol, in parrot plasma. Sample workup involved acetonitrile protein precipitation, ethyl acetate extraction, followed by back extraction into HCl. Separations were achieved on a phenyl-hexyl column at 30 degrees C using acetonitrile (17%, v/v) in 0.01 M orthophosphoric acid (83%, v/v) delivered via a linear flow program. Fluorometric detection wavelengths were 235 nm (excitation) and 550 nm (emission). Calibration plots were linear (r2>0.999), and recoveries were 71-87% from 20 to 400 ng/mL. Assay imprecision was 相似文献   

19.
A HPLC method with UV detection (210 nm) was developed and validated for the quantification of atomoxetine, a new medication for the treatment of attention deficit/hyperactivity disorder, in human plasma. Following a two-step liquid-liquid extraction with diethyl ether, the analyte and internal standard (maprotiline) were separated using an isocratic mobile phase of acetonitrile/phosphate buffer (39/61, v/v, pH 6.6) on a reverse phase Inertsil C(18) column. Linearity was verified over the range of 3.12-200 ng/mL atomoxetine in plasma. The lowest limit of detection is 2.5 ng/mL (S/N=10). This HPLC method was validated with within- and between-batch precisions of 4.9-14.4% and 4.7-13.1%, respectively. The within- and between-batch biases were -1.9 to 1.4% and 0.1-13.8%, respectively. Commonly used psychotropic drugs and frequently coadministered drugs did not interfere with the drug and internal standard. This method is simple, economical and specific, and has been used successfully in a pharmacokinetic study of atomoxetine.  相似文献   

20.
A sensitive and specific method for the simultaneous determination of the unchanged drug (solifenacin) and its major metabolite (M1, 4S-hydroxy solifenacin) in rat plasma was developed and validated. Both solifenacin and M1 were extracted from rat plasma by a two-step liquid-liquid extraction and analyzed by semi-micro HPLC with UV detection at an absorbance wavelength of 220 nm. The chromatographic separations were performed on a TSKgel ODS-80Ts (5 microm, 150 mmx2.0 mm i.d.) reversed-phase column with a mobile phase of 0.1 M phosphate buffer (pH 3.0):acetonitrile (71:29, v/v). The intra-day precision (expressed as coefficient of variation, CV) ranged from 0.4% to 1.7%, and the accuracy (expressed as relative error, RE) ranged from -5.2% to 2.0% for solifenacin. The corresponding precision ranged from 1.3% to 3.2%, and accuracy ranged from -4.0% to 8.6% for M1. The lower limit of quantitation for both solifenacin and M1 was 2 ng/ml when 1 ml of plasma was used. No endogenous interference was observed in rat plasma.  相似文献   