首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A study is made of radio-wave scattering by Langmuir turbulent pulsations in a plasma in a magnetic field. The effect of this process on the polarization of radio waves at frequencies far above or close to the electron plasma frequency is investigated. The wave scattering by Langmuir turbulence is shown to strongly affect the polarization characteristics. When the optical thickness typical of the scattering process is on the order of unity, the degree of wave polarization can change by 30% both at high frequencies and at frequencies close to the plasma frequency, in which case the circular polarization can reverse direction. It is shown that, as a result of wave scattering by Langmuir turbulence, the degree of circular polarization of radio waves depends on the wavelength even in a uniform magnetic field.  相似文献   

2.
An analytic approach is developed to describing how ultrashort electromagnetic pulses with a duration of one period or less at the carrier frequency are scattered in a plasma. Formulas are derived to calculate and analyze the angular and spectral probabilities of radiation scattering via two possible mechanisms-Compton and transition radiation channels-throughout the entire pulse. Numerical simulations were carried out for a Gaussian pulse. The effect of the phase of the carrier frequency relative to the pulse envelope on the scattering parameters is investigated.  相似文献   

3.
The mechanism of stochastic electron acceleration and heating by a picosecond laser pulse in underdense plasma is studied using particle-in-cell simulations and theoretical models. The formation of wide electron energy spectra in the simultaneously acting laser and plasma fields is analyzed. It is shown that electron scattering by turbulent plasma fluctuations excited through stimulated forward Raman scattering plays a governing role in the formation of high-energy tails in the electron distribution function.  相似文献   

4.
The interfacial nonuniformity of the electron density that occurs in metals as a result of atomic imperfections can strongly affect the plasmonic properties of metallic nanostructures. Under certain conditions, it induces the bulk plasmon resonance in the transition area and can significantly change scattering and absorption of light by metallic nanostructures in a broad frequency range. This effect is numerically demonstrated for radially nonuniform spherical silver nanoparticles and analytically investigated with respect to the resonant coupling with the dipolar surface plasmons of the metal core.  相似文献   

5.
It is shown that a short laser pulse propagating in a plasma with electron density fluctuations can emit electromagnetic waves with frequencies much lower than the laser carrier frequency. Emissions with frequencies close to the plasma frequency and the doubled plasma frequency in a nonisothermal plasma, as well as emission generated in a turbulent plasma, are examined. The effects in question are related to the transformation of the laser pulse wakefield into electromagnetic radiation by electron density fluctuations. The phenomenon under study opens new possibilities for diagnostics of both plasma fields excited by laser pulses and electron density fluctuations in a plasma.  相似文献   

6.
It is shown that the nonlinear currents generated in plasma by a radiation pulse with a frequency exceeding the electron plasma frequency change substantially due to a reduction in the effective electron–ion collision frequency.  相似文献   

7.
Research on the function of acoustic signals has focused on high-amplitude long-range songs (LRS) and largely ignored low-amplitude songs produced by many species during close-proximity, conspecific interactions. Low-amplitude songs can be structurally identical to LRS (soft LRS), or they can be widely divergent, sharing few spectral and temporal attributes with LRS (short-range song [SRS]). SRS is often more complex than LRS and is frequently sung by males during courtship. To assess function, we performed two playback experiments on males of a socially monogamous songbird. We compared responses of males whose mates were fertile or nonfertile with differences in song structure (SRS vs. LRS and soft LRS), amplitude (SRS and soft LRS vs. LRS), and tempo (slow SRS vs. fast SRS). Males responded more strongly to SRS than to LRS or soft LRS, indicating that song structure had a greater effect on response than song amplitude. SRS tempo did not detectably affect male response. Importantly, males responded more strongly to SRS when their mates were fertile, presumably because hearing SRS can indicate that a male's mate is being courted by an intruding male and a strong response can deter extrapair competitors. We conclude that low-amplitude songs can function in both inter- and intrasexual communication and should receive greater attention in future studies of mate choice and male-male competition.  相似文献   

8.
A repetitively rated microwave oscillator whose frequency can be varied electronically from pulse to pulse in a predetermined manner is created for the first time. The microwave oscillator has a power on the order of 108 W and is based on the Cherenkov interaction of a high-current relativistic electron beam with a plasma preformed before each pulse. Electronic control over the plasma properties allows one to arbitrarily vary the microwave frequency from pulse to pulse at a pulse repetition rate of up to 50 Hz.  相似文献   

9.
Dependence of the shape of a microwave pulse in a plasma relativistic microwave amplifier (PRMA) on the initial plasma electron density in the system is detected experimentally. Depending on the plasma density, fast disruption of amplification, stable operation of the amplifier during the relativistic electron beam (REB) pulse, and its delayed actuation can take place. A reduction in the output signal frequency relative to the input frequency is observed experimentally. The change in the shape of the microwave signal and the reduction in its frequency are explained by a decrease in the plasma density in the system. The dynamics of the plasma density during the REB pulse is determined qualitatively from the experimental data by using the linear theory of a PRMA with a thin-wall hollow electron beam. The processes in a PRMA are analyzed by means of the KARAT particle-in-cell code. It is shown that REB injection is accompanied by an increase in the mean energy of plasma electrons and a significant decrease in their density.  相似文献   

10.
Identification of genes regulating fat accumulation is important for basic and medical research; genetic screening for those genes in Caenorhabditis elegans, a widely used model organism, requires in vivo quantification of lipids. We demonstrated RNA interference screening based on quantitative imaging of lipids with label-free stimulated Raman scattering (SRS) microscopy, which overcomes major limitations of coherent anti-Stokes Raman scattering microscopy. Our screening yielded eight new genetic regulators of fat storage.  相似文献   

11.
A study is made of the interaction (“collision”) of two laser pulses with the same frequency but different durations, propagating toward one another in a low-density plasma. It is found that, in the interaction region, the excitation of small-scale plasma fields localized within a distance on the order of the length of the longer pulse is accompanied by the backscattering of each of the pulses. The frequency shift of the backscattered radiation and its duration depend strongly on the lengths of the interacting pulses. It is shown that the spectrum of the long backscattered radiation “tail” that arises behind the shorter pulse as a result of its interaction with the longer pulse contains satellites shifted from the laser frequency by the plasma frequency.  相似文献   

12.
Results are presented from a theoretical investigation of the acceleration of test electrons by a Langmuir wave excited by a short laser pulse at half the electron plasma frequency. Such a pulse penetrates into the plasma over a distance equal to the skin depth and efficiently excites Langmuir waves in the resonant interaction at the second harmonic of the laser frequency. It is shown that the beam of electrons accelerated by these waves is modulated into a train of electron bunches, but because of the initial thermal spread of the accelerated electrons, the bunches widen and begin to overlap, with the result that, at large distances, the electron beam becomes unmodulated.  相似文献   

13.
Structure of myosin subfragment 1 from low-angle X-ray scattering   总被引:5,自引:0,他引:5  
The X-ray scattering pattern produced by a solution of myosin subfragment 1 has been measured to a resolution (Bragg spacing) of 2 nm. We find that for subfragment 1 (S1) prepared by limited papain digestion in the presence of ethylenediaminetetraacetate the radius of gyration is 3.28 +/- 0.06 nm, the volume is 151 +/- 6 nm3, the surface area is 330 +/- 15 nm2, and the length of the maximum chord is 12.0 +/- 1.0 nm. The theoretical scattering patterns from several objects of uniform electron density have been calculated and compared with the observed scattering produced by S1. The recent three-dimensional electron micrograph reconstruction of S1-decorated actin by J. Seymour and E. O'Brien (private communication) generated the calculated pattern that best fit the observed scattering. This fit strongly suggests that this reconstruction resembles subfragment 1. The good correspondence between an S1 structure derived when S1 is attached to actin and a study of free S1 in solution strongly suggests that binding to actin does not grossly distort the shape of S1. This is consistent with the notion that S1 changes its orientation on actin, rather than its shape, in order to generate the contractile force in muscle.  相似文献   

14.
AimDevelopment of MRI sequences and processing methods for the production of images appropriate for direct use in stereotactic radiosurgery (SRS) treatment planning.BackgroundMRI is useful in SRS treatment planning, especially for patients with brain lesions or anatomical targets that are poorly distinguished by CT, but its use requires further refinement. This methodology seeks to optimize MRI sequences to generate distortion-free and clinically relevant MR images for MRI-only SRS treatment planning.Materials and methodsWe used commercially available SRS MRI-guided radiotherapy phantoms and eight patients to optimize sequences for patient imaging. Workflow involved the choice of correct MRI sequence(s), optimization of the sequence parameters, evaluation of image quality (artifact free and clinically relevant), measurement of geometrical distortion, and evaluation of the accuracy of our offline correction algorithm.ResultsCT images showed a maximum deviation of 1.3 mm and minimum deviation of 0.4 mm from true fiducial position for SRS coordinate definition. Interestingly, uncorrected MR images showed maximum deviation of 1.2 mm and minimum of 0.4 mm, comparable to CT images used for SRS coordinate definition. After geometrical correction, we observed a maximum deviation of 1.1 mm and minimum deviation of only 0.3 mm.ConclusionOur optimized MRI pulse sequences and image correction technique show promising results; MR images produced under these conditions are appropriate for direct use in SRS treatment planning.  相似文献   

15.
Stimulated Raman scattering (SRS) microscopy is a nonlinear optical imaging method for visualizing chemical content based on molecular vibrational bonds. However, the imaging speed and sensitivity are currently limited by the noise of the light beam probing the Raman process. In this paper, we present a fast non-average denoising and high-precision Raman shift extraction method, based on a self-reinforcing signal-to-noise ratio (SNR) enhancement algorithm, for SRS spectroscopy and microscopy. We compare the results of this method with the filtering methods and the reported experimental methods to demonstrate its high efficiency and high precision in spectral denoising, Raman peak extraction and image quality improvement. We demonstrate a maximum SNR enhancement of 10.3 dB in fixed tissue imaging and 11.9 dB in vivo imaging. This method reduces the cost and complexity of the SRS system and allows for high-quality SRS imaging without use of special laser, complicated system design and Raman tags.  相似文献   

16.
The dispersion law and collisionless damping rate of quasi-potential waves in the plasma formed upon tunnel ionization of gas atoms in the field of a short pulse of circularly or linearly polarized radiation are found. It is shown how the frequency and damping rate of quasi-potential waves depend on the wave propagation direction relative to the symmetry axis of the photoelectron distribution. It is established that, in plasma with a toroidal photoelectron velocity distribution, weakly damped waves with a linear dispersion law and frequency above the electron plasma frequency can propagate in a wide range of angles. In the case of a bi-Maxwellian photoelectron distribution, the frequency of weakly damped waves is comparable with the electron plasma frequency and the anisotropy of electron motion manifests itself in relatively small corrections to the dispersion law.  相似文献   

17.
A relativistic plasma microwave amplifier with a gain of about 30 dB and an output power of about 60–100 MW in the frequency range from 2.4 to 3.2 GHz is studied experimentally. The total duration of the output microwave pulse is equal to the duration of the current pulse of the driving relativistic electron beam (500 ns); however, the maximum output power is observed only within 200 ns. It is shown that variations in the output microwave power during the current pulse of the annular relativistic electron beam are caused by variations in the beam radius and thickness. Analysis of the experimental data and results of numerical simulations show that the thickness of the electron beam is determined by the density of the cathode emission current.  相似文献   

18.
Stimulated Raman scattering (SRS) microscopy is a label‐free method generating images based on chemical contrast within samples, and has already shown its great potential for high‐sensitivity and fast imaging of biological specimens. The capability of SRS to collect molecular vibrational signatures in bio‐samples, coupled with the availability of powerful statistical analysis methods, allows quantitative chemical imaging of live cells with sub‐cellular resolution. This application has substantially driven the development of new SRS microscopy platforms. Indeed, in recent years, there has been a constant effort on devising configurations able to rapidly collect Raman spectra from samples over a wide vibrational spectral range, as needed for quantitative analysis by using chemometric methods. In this paper, an SRS microscope which exploits spectral shaping by a narrowband and rapidly tunable acousto‐optical tunable filter (AOTF) is presented. This microscope enables spectral scanning from the Raman fingerprint region to the Carbon‐Hydrogen (CH)‐stretch region without any modification of the optical setup. Moreover, it features also a high enough spectral resolution to allow resolving Raman peaks in the crowded fingerprint region. Finally, application of the developed SRS microscope to broadband hyperspectral imaging of biological samples over a large spectral range from 800 to 3600 cm?1, is demonstrated.  相似文献   

19.
Cholesterol crystals (ChCs) have been identified as a major factor of plaque vulnerability and as a potential biomarker for atherosclerosis. Yet, due to the technical challenge of selectively detecting cholesterol in its native tissue environment, the physiochemical role of ChCs in atherosclerotic progression remains largely unknown. In this work, we demonstrate the utility of hyperspectral stimulated Raman scattering (SRS) microscopy combined with second-harmonic generation (SHG) microscopy to selectively detect ChC. We show that despite the polarization sensitivity of the ChC Raman spectrum, cholesterol monohydrate crystals can be reliably discriminated from aliphatic lipids, from structural proteins of the tissue matrix and from other condensed structures, including cholesteryl esters. We also show that ChCs exhibit a nonvanishing SHG signal, corroborating the noncentrosymmetry of the crystal lattice composed of chiral cholesterol molecules. However, combined hyperspectral SRS and SHG imaging reveals that not all SHG-active structures with solidlike morphologies can be assigned to ChCs. This study exemplifies the merit of combining SRS and SHG microscopy for an enhanced label-free chemical analysis of crystallized structures in diseased tissue.  相似文献   

20.
Millions of women worldwide have silicone breast implants. It has been reported that implant failure occurs in approximately a tenth of patients within 10 years, and the consequences of dissemination of silicone debris are poorly understood. Currently, silicone detection in histopathological slides is based on morphological features as no specific immunohistochemical technique is available. Here, we show the feasibility and sensitivity of stimulated Raman scattering (SRS) imaging to specifically detect silicone material in stained histopathological slides, without additional sample treatment. Histology slides of four periprosthetic capsules from different implant types were obtained after explantation, as well as an enlarged axillary lymph node from a patient with a ruptured implant. SRS images coregistered with bright‐field images revealed the distribution and quantity of silicone material in the tissue. Fast and high‐resolution imaging of histology slides with molecular specificity using SRS provides an opportunity to investigate the role of silicone debris in the pathophysiology of implant‐linked diseases.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号