首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A HPLC method is described for the simultaneous determination of d-fenfluramine (FEN), d-norfenfluramine (NF) and fluoxetine (FLX) using fluorometric detection after precolumn derivatization with dansyl-chloride. The method has limits of quantitation of 200 fmol for FEN and NF, 500 fmol for FLX in brain microdialysate, and 1 pmol for NF and FEN, and 2 pmol for FLX in plasma. Brain tissue standards were linear between 5 and 200 pmol/mg for all three compounds. The inter-assay variability (relative standard deviation) was 6.6%, 6.9% and 9.3% for FEN, 4.6%, 3.7% and 7.9% for NF and 10.4%, 4.9% and 12.2% for FLX, for brain microdialysate (2 pmol/μl), plasma (2 pmol/ μl) and brain tissue (50 pmol/mg), respectively. Intra-assay variability was always lower, typically several times lower than inter-assay variability. Extraction recovery was 108% and 48% for FEN, 105% and 78% for NF and 94% and 45% for FLX, in plasma (2 pmol/μl) and brain tissue (5 pmol/mg), respectively. Due to the stability of the dansyl-chloride derivatives this method is well suited for an autoinjector after manual derivatization with dansyl chloride at room temperature for 4 h.  相似文献   

2.
A HPLC method is described for the simultaneous determination of d-fenfluramine (FEN), d-norfenfluramine (NF) and fluoxetine (FLX) using fluorometric detection after precolumn derivatization with dansyl-chloride. The method has limits of quantitation of 200 fmol for FEN and NF, 500 fmol for FLX in brain microdialysate, and 1 pmol for NF and FEN, and 2 pmol for FLX in plasma. Brain tissue standards were linear between 5 and 200 pmol/mg for all three compounds. The inter-assay variability (relative standard deviation) was 6.6%, 6.9% and 9.3% for FEN, 4.6%, 3.7% and 7.9% for NF and 10.4%, 4.9% and 12.2% for FLX, for brain microdialysate (2 pmol/μl), plasma (2 pmol/ μl) and brain tissue (50 pmol/mg), respectively. Intra-assay variability was always lower, typically several times lower than inter-assay variability. Extraction recovery was 108% and 48% for FEN, 105% and 78% for NF and 94% and 45% for FLX, in plasma (2 pmol/μl) and brain tissue (5 pmol/mg), respectively. Due to the stability of the dansyl-chloride derivatives this method is well suited for an autoinjector after manual derivatization with dansyl chloride at room temperature for 4 h.  相似文献   

3.
An iodometric method for the analysis of hydroperoxides has been automated to allow analysis of aqueous biological samples (containing less than 20 mg/ml protein) and lipid hydroperoxide extracts. The evolution of triiodide ions is measured spectrophotometrically at 360 nm. Dependent on the type of sample, 30-60 samples can be analyzed per hour and the system allows detection of less than 100 pmol of peroxide. The assay is linear over a range of 100 pmol to 25 nmol. The sample volume used routinely was 80 microliters.  相似文献   

4.
3-Nitrotyrosine (3NT) is used as a biomarker of nitrative pathology caused by peroxynitrite (PN), myeloperoxidase (MPO)-, and/or eosinophil peroxidase (EPO)-dependent nitrite oxidation. 3NT measurements in biological materials are usually based on either antibody staining, HPLC detection, or GC detection methodologies. In this report, a procedure is described for the measurement of 3NT and tyrosine (TYR) by LC-MS/MS that is simple, direct, and sensitive. Though highly specialized in its use as an assay, LC-MS/MS technology is available in many research centers in academia and industry. The critical assay for 3NT was linear below 100 ng/ml and the limit of detection was below 100 pg/ml. Regarding protein digested samples, we found that MRM was most selective with 133.1 m/z as the daughter ion. In comparison, LC-ECD was 100 times less sensitive. Basal levels of 3NT in extracted digests of rat brain homogenate were easily detected by LC-MS/MS, but were below detection by LC-ECD. The LC-MS/MS assay was used to detect 3NT in rat brain homogenate that was filtered through a 180 micron nylon mesh. Three fractions were collected and examined by phase contrast microscopy. The mass ratio (3NT/TYR) of 3NT in fractions of large vessel enrichment, microvessel enrichment, and vessel depletion was 0.6 ng/mg, 1.2 ng/mg, and 0.2 ng/mg, respectively. Ultimately, we found that the basal 3NT/TYR mass ratio as determined by LC-MS/MS was six times greater in microvessel-enriched brain tissue vs. tissue devoid of microvessels.  相似文献   

5.
Estimation of methanogen biomass by quantitation of coenzyme M   总被引:2,自引:0,他引:2  
Determination of the role of methanogenic bacteria in an anaerobic ecosystem often requires quantitation of the organisms. Because of the extreme oxygen sensitivity of these organisms and the inherent limitations of cultural techniques, an accurate biomass value is very difficult to obtain. We standardized a simple method for estimating methanogen biomass in a variety of environmental matrices. In this procedure we used the thiol biomarker coenzyme M (CoM) (2-mercaptoethanesulfonic acid), which is known to be present in all methanogenic bacteria. A high-performance liquid chromatography-based method for detecting thiols in pore water (A. Vairavamurthy and M. Mopper, Anal. Chim. Acta 78:363-370, 1990) was modified in order to quantify CoM in pure cultures, sediments, and sewage water samples. The identity of the CoM derivative was verified by using liquid chromatography-mass spectroscopy. The assay was linear for CoM amounts ranging from 2 to 2,000 pmol, and the detection limit was 2 pmol of CoM/ml of sample. CoM was not adsorbed to sediments. The methanogens tested contained an average of 19.5 nmol of CoM/mg of protein and 0.39 +/- 0.07 fmol of CoM/cell. Environmental samples contained an average of 0.41 +/- 0.17 fmol/cell based on most-probable-number estimates. CoM was extracted by using 1% tri-(N)-butylphosphine in isopropanol. More than 90% of the CoM was recovered from pure cultures and environmental samples. We observed no interference from sediments in the CoM recovery process, and the method could be completed aerobically within 3 h. Freezing sediment samples resulted in 46 to 83% decreases in the amounts of detectable CoM, whereas freezing had no effect on the amounts of CoM determined in pure cultures. The method described here provides a quick and relatively simple way to estimate methanogenic biomass.  相似文献   

6.
A sensitive method for the assay of sparteine oxidase activity in vitro by microsomal fractions of human liver is described. The activity of sparteine oxidase was assessed by the formation of 2- and 5-dehydrosparteines, which were estimated by capillary gas chromatography with N2-FID detection. The limit of detection of the two metabolites, 2- and 5-dehydrosparteine, was 10 pmol (2.3 ng) per sample. Sparteine oxidase activity was linear with microsomal protein concentration ranging from 25 to 200 ug and with incubation times between 5 and 60 minutes. Omission of NADPH on incubation under an atmosphere of carbon monoxide inhibited formation of both metabolites, thus indicating that aforementioned metabolites arise in reaction catalyzed by cytochrome P-450. In three liver samples from humans classified as extensive (EM) metabolizers the formation of 2- and 5-dehydrosparteines was observed, 2-dehydrosparteine being the major metabolite. In these samples sparteine oxidase activity was characterised by Vmax = 136 +/- 53 pmol/min/mg and Km = 44 +/- 12 microM for 2-dehydrosparteine formation. For 5-dehydrosparteine formation the following values were obtained: Vmax = 57 +/- 18 pmol/min/mg and Km = 42 +/- 26 microM. In a liver sample from a poor metabolizer (PM) only the formation of 2-dehydrosparteine was detected with the method of analysis used. In this sample a great increase in Km (Km PM = 3033 microM) was noted, while Vmax was very similar to those obtained for 2-dehydrosparteine formation in EM subjects (Vmax PM = 147 pmol min/mg).  相似文献   

7.
A determination of glutathione, cysteine, and their disulfides using HPLC and dual electrochemical detection (HPLC-DEC) was described previously but was not validated in biological tissues for these and other important thiols and disulfides (SH/SS). Thus, our objectives were to develop this method to quantify simultaneously reduced and oxidized glutathione, cysteine, cystine, and other SH/SS in various tissues, including human blood and plasma, rat liver and hippocampus, mosquito, and spinach leaf. Optimal conditions were determined for sample processing and analysis using metaphosphoric acid and HPLC-DEC. Authentic standards of 10 common SH/SS compounds were resolved and eluted within 15 min, and all standard curves were linear from 5 to 1600 pmol. Validation was based on the following: First, tissue sample sizes were proportional to peak areas over an eightfold range. Second, recovery of SH/SS added to samples before processing was 96-101%. Finally, the results were equivalent and correlated highly with values for total SH by 5,5'-dithiobis-(2-nitrobenzoic acid) (DTNB) assay (r2 = 0.996) and for total glutathione by DTNB-GSSG reductase assay (r2 = 0.998). The life span of the Au/Hg electrode was limited to 200-500 samples based on the lineal range of standard curves. On the basis of these results, we believe that this method will fill a long-time need for the simultaneous determination of SH/SS in biological tissues.  相似文献   

8.
A rapid and selective method of sample clean-up using immunoaffinity chromatography (IAC) was developed to isolate enkephalins from plasma. The enkephalin antibodies were produced utilizing novel protein carriers. Two antibodies, LE4H8 and 33FC6, were selected because of their moderate binding affinity and different epitopes. Enkephalin-spiked plasma was loaded onto the immunoaffinity column and eluted with acidic pH buffer. The eluate was derivatized with naphthalene-2,3-dicarboxaldehyde in the presence of cyanide (NDA-CN), and the enkephalins were separated using reversed-phase liquid chromatography (RPLC). IAC sample clean-up of enkephalin-spiked plasma was compared to the existing solid-phase extraction method. The limit of detection for IAC was 30 pmol. The recovery of the enkephalins from plasma was 90% with a variance ranging from 2 to 9%. The immunoaffinity column was used for approximately 70 samples without any deterioration in performance.  相似文献   

9.
The antiretroviral therapeutic drug monitoring is becoming increased in clinical care to determine the best dosage regimen adapted to each patient. Here, the determination of the anti-HIV drugs lamivudine, lopinavir, and ritonavir concentration in the plasma of HIV-infected patients by MALDI-TOF/TOF is reported. The volume of the plasma sample was 600 microL. Plasma samples were extracted by solid-phase (divinylbenzene and N-vinylpyrrolidone) and evaporated in a water bath under a nitrogen stream. The extracted samples were reconstituted with methanol (100 microL), mixed (1:1) with a saturated matrix solution (4-hydroxybenzoic acid in 50% acetonitrile-0.1% trifluoracetic acid), and spotted onto the MALDI-TOF/TOF sample target plate. The lamivudine, lopinavir and ritonavir concentration was determined by standard additions analysis. Regression of standard additions was linear over the anti-HIV drug concentration ranges explored (lamivudine, 0.010-1.0 pmol/microL; lopinavir and ritonavir, 0.0025-0.50 pmol/microL). Moreover, emtricitabine (i.e., the fluorinated analog of lamivudine) was used as the internal standard to determine the lamivudine concentration. The calibration curve was linear on the emtricitabine concentration ranging between 0.050 and 5.0 pmol/microL. The absolute recovery ranged between 80 and 110%. Values of the lamivudine, lopinavir and ritonavir concentration determined by MALDI-TOF/TOF are in excellent agreement with those obtained by HPLC-UV and HPLC-MS/MS. MALDI-TOF/TOF experiments allowed also the detection of the ritonavir metabolite R5. Zidovudine was undetectable by MALDI-TOF/TOF analysis because also the minimal laser intensity may induce the anti-HIV drug photolysis. The MALDI-TOF/TOF technique is useful to determine very low concentrations of anti-HIV drugs (0.0025-0.010 pmol/microL).  相似文献   

10.
Beta-endorphin (BE) and neurotensin (NT) are two neuropeptides which induce apneas. In infants who died of Sudden Infant Death Syndrome (SIDS) we measured, in brainstem and CSF, BE and NT by IRMA and RIA respectively. BE and NT levels are compared to same aged infant and adult controls. CSF BE level was significantly higher in SIDS than in the two control groups (86 +/- 14 vs 33 +/- 13 and 16 +/- 5 pmol/l). In 6 SIDS victims NT and BE were assayed in 5 brainstem sections, each of them divided in median, intermediate and lateral parts. We found high levels of BE in every fragment (3-11 pmol/mg protein) while NT elevated values were restricted to the mesencephalic regions (1.4-12 pmol/mg), the medial pons (6 pmol/mg) and the intermediate parts of the medulla (including the olive: 1.3-1.6 pmol/mg). These results support the hypothesis that NT and/or BE could induce or participate to the fetal issue of SIDS.  相似文献   

11.
《Luminescence》2003,18(2):72-78
We developed a competitive chemiluminescent (CL) enzyme immunoassay for rapid, sensitive analysis of 19‐nortestosterone (19‐NT) in bovine urine. Anti‐19‐NT polyclonal antibodies were raised in rabbits using a 19‐NT‐hemisuccinate derivative conjugated with ovalbumin; the derivative was also conjugated with horseradish peroxidase (HRP) as a label. Antibodies were immobilized on 384‐well black polystyrene microtitre plates and HRP‐labelled 19‐NT activity was measured using an efficient chemiluminescent substrate (SuperSignal® ELISA Femto) after 3 min incubation. Emitted light was recorded using a conventional, photomultiplier‐tube‐based microtitre plate reader or a sensitive back‐illuminated, cooled CCD camera. The developed method fulfils all the requirements of precision (intra‐ and inter‐assay CV < 10%) and accuracy (mean recovery 94–112%), with a detection limit of 0.03 ppb (1.1 × 10?9 mol/L) in a urine matrix. Chemiluminescence enhances detectability of the HRP‐labelled tracer (thus lowering the limit of detection with respect to colorimetry) and reduces analysis time. The 384‐well microtitre plate cuts the sample/reagent volume (20 µL), a five‐fold reduction with respect to the conventional 96‐well microtitre plate. The developed method is suitable for high‐throughput screening of 19‐NT in urine samples, with reduced costs as compared with conventional colorimetric enzyme immunoassays. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

12.
Estimation of Methanogen Biomass by Quantitation of Coenzyme M   总被引:1,自引:0,他引:1       下载免费PDF全文
Determination of the role of methanogenic bacteria in an anaerobic ecosystem often requires quantitation of the organisms. Because of the extreme oxygen sensitivity of these organisms and the inherent limitations of cultural techniques, an accurate biomass value is very difficult to obtain. We standardized a simple method for estimating methanogen biomass in a variety of environmental matrices. In this procedure we used the thiol biomarker coenzyme M (CoM) (2-mercaptoethanesulfonic acid), which is known to be present in all methanogenic bacteria. A high-performance liquid chromatography-based method for detecting thiols in pore water (A. Vairavamurthy and M. Mopper, Anal. Chim. Acta 78:363–370, 1990) was modified in order to quantify CoM in pure cultures, sediments, and sewage water samples. The identity of the CoM derivative was verified by using liquid chromatography-mass spectroscopy. The assay was linear for CoM amounts ranging from 2 to 2,000 pmol, and the detection limit was 2 pmol of CoM/ml of sample. CoM was not adsorbed to sediments. The methanogens tested contained an average of 19.5 nmol of CoM/mg of protein and 0.39 ± 0.07 fmol of CoM/cell. Environmental samples contained an average of 0.41 ± 0.17 fmol/cell based on most-probable-number estimates. CoM was extracted by using 1% tri-(N)-butylphosphine in isopropanol. More than 90% of the CoM was recovered from pure cultures and environmental samples. We observed no interference from sediments in the CoM recovery process, and the method could be completed aerobically within 3 h. Freezing sediment samples resulted in 46 to 83% decreases in the amounts of detectable CoM, whereas freezing had no effect on the amounts of CoM determined in pure cultures. The method described here provides a quick and relatively simple way to estimate methanogenic biomass.  相似文献   

13.
The postulated importance of oxidative damage to DNA in aging and age-related degenerative pathologies such as cancer has prompted efforts to develop sensitive quantitation methods. 8-Hydroxy-2′-deoxyguanosine (8-OHdG) is a widely used marker for oxidative damage to DNA. To develop an immunoassay for quantitation of 8-OHdG, two monoclonal antibodies have been developed and characterized by competitive enzyme-linked immunosorbent assay (ELISA). Antibody 1F7 has 50% inhibition at 5 pmol 8-OHdG and 1 × 105 pmol dG, while antibody IF11 has 50% inhibition at 2.5 pmol 8-OHdG and 2000 pmol dG. Both antisera crossreact with guanosine and several structurally related derivatives, including 6-and 8-mercaptoguanosine, 8-bromoguanosine, 8-methylguanine, and 7-methylguanosine. Immunoaffinity columns were prepared with antibody 1F7, which exhibits higher selectivity than 1F11, to isolate 8-OHdG from DNA hydrolyzates followed by ELISA quantitation with antibody 1F11. This method allows the analysis of approximately one 8-OHdG/105 dG using 100μg DNA. To validate the assay, DNA extracted from human placental tissues were assayed by both ELISA and HPLC with electrochemical detection. Values by both methods correlated well (r = 0.87, p < 0.001), but the levels determined by ELISA were approximately sixfold higher than those determined by HPLC. This may be due to oligonucleotides detected by the ELISA but not the HPLC method or crossreactivity with other damaged bases present in the immunoaffinity purified material. Placental samples from current smokers had significantly higher 8-OHdG by ELISA than those from nonsmokers (p < 0.05). The method of immunoaffinity purification combined with ELISA quantitation has sufficient sensitivity for detecting 8-OHdG in human DNA samples. Although absolute values are higher than those determined by HPLC, the method provides a good alternative to the HPLC-EC method for monitoring relative oxidative damage in molecular epidemiological studies.  相似文献   

14.
A simple and sensitive gas chromatographic method has been developed for the determination of timolol in plasma using electron-capture detection and propranolol as internal standard. Timolol was extracted using butyl chloride and derivatized using trifluoroacetic anhydride in butyl acetate. The lower detection limit for the assay was found to be 1 ng/ml from 1 ml of plasma. Extracted standards gave within-day precision of 12.55, 9.68 and 3.78% for 1, 20 and 100 ng/ml plasma samples, respectively. A recovery of at least 80% of timolol was found using the extraction method described. The assay was used in a randomized cross-over bioequivalence trial using an oral administration of 20 mg of timolol. Pharmacokinetic parameters compare favourably with other literature values.  相似文献   

15.
Time efficient and comprehensive quantification of amino acids continues to be a challenge. We developed a sensitive and precise method for quantitative analysis of amino acids from very small plasma and serum volumes. Ion-pair chromatography of amino acid butyl esters proved to provide an optimal combination of selectivity, sensitivity and robustness. 10 μL of plasma or serum are added to precipitation reagent containing stable isotope standards. After protein precipitation, the supernatants is dried and incubated with 3N butanolic HCl for improving chromatographic separation and ionization efficiency. Amino acid butyl esters are separated using ion-pair (heptafluorobutyric acid) reversed-phase chromatography coupled to triple quadrupole mass spectrometry. The established method enables quantitative analysis of 22 amino acids, all 20 proteinogenic amino acids, ornithine and citrulline. Cysteine is measured as cystine. The combination of precipitation, derivatization and chromatographic separation effectively avoids ion suppression and coelution. Simultaneous with quantification, analyte identity is verified in each sample using qualifier ions. The micro-method is very sensitive and accurate. The intra-assay precision for the analysis of plasma was 2.6-10.1%. Absolute accuracy as determined by comparison of external reference samples was 82-117.7%. Excellent linearity of detection response was demonstrated for all compounds in the range representative for clinical samples from infants and adults. Lower limits of quantification were in the range of 1 μmol/L for all analytes. In conclusion, the method is ideally suited for cost-effective high-throughput analysis of large numbers of samples in clinical studies and metabolomics research.  相似文献   

16.
Thioredoxin-1 (Trx1) is a protein antioxidant involved in major cellular processes. Increased plasma levels of Trx1 have been associated with human diseases suggesting that Trx1 is a marker for oxidative stress with putative clinical use. However, the reported mean levels of Trx1 in the control cohorts vary a hundred-fold between studies (0.8–87 ng/ml), possibly due to methodological differences between the capture ELISA used in the different studies. The aim of this study was to investigate methodological aspects related to the ELISA measurement of Trx1. ELISAs utilizing different capture and detection combinations of antibodies to Trx1 and as well as recombinant human (rh) Trx1 standards from two sources were characterized. The different ELISAs were subsequently used to measure Trx1 in human plasma and cerebrospinal fluid samples (CSF) from healthy donors and from patients with various neurological diagnoses. The Trx1 standards differed in their content of monomeric and oligomeric Trx1, which affected the ELISAs composed of different antibody combinations. Thus, the levels of Trx1 determined in human plasma and CSF samples varied depending on the antibody used in the ELISAs and on the rhTrx1 standard. Furthermore, the relevance of preventing interference by heterophilic antibodies (HA) in human plasma and CSF was investigated. The addition of a HA blocking buffer to human samples drastically reduced the ELISA signals in many samples showing that HA are likely to cause false positive results unless they are blocked. In conclusion, the study shows that the design of a Trx1 ELISA in regards to antibodies and standards used has an impact on the measured Trx1 levels. Importantly, analyses of human plasma and CSF without preventing HA interference may obscure the obtained data. Overall, the results of this study are crucial for the improvement of future studies on the association of Trx1 levels with various diseases.  相似文献   

17.
A method is described for the simultaneous determination of l-α-acetylmethadol (LAAM) and its N-demethylated metabolites, l-α-noracetylmethadol (norLAAM) and l-α-dinoracetylmethadol (dinorLAAM), in plasma by gas chromatography—chemical ionization mass spectrometry. Deuterated internal standards for each analyte serve as carriers and control for recovery during sample purification on a solid-phase extraction column (C18), and subsequent separation and analysis on a DB-17 capillary column. With this method, we have determined levels of LAAM, norLAAM, and dinorLAAM in small volumes of plasma (100 μl). The limit of quantitation for all analytes was approximately 1.0 ng/g plasma and the limit of detection was approximately 0.5 ng/g plasma. An experimental application is also described where these analytes are quantitated in plasma obtained from rats before, during, and after chronic administration of LAAM-HCl. Since this technique affords a selective and sensitive means of detection of LAAM and its active, N-demethylated metabolites in small samples of blood, it may enable patient compliance to be more easily assessed by allowing samples to be collected by a simple finger-prick technique.  相似文献   

18.
The effect of neurotensin (NT) on the release of endogenous dopamine (DA) of rat striatal synaptosomes was studied. In the basic medium with Ca++ (5mM K+ and 1.2 mM Ca++), spontaneous release of DA was determined to be 12.03 +/- 1.12 pmol/mg protein, while in the Ca++-free basic medium containing EGTA (2.0 mM), the amount of DA released was still up to 11.2 +/- 1.06 pmol/mg protein. NT in 10(-4)-10(-6) M range tested potentiated both the spontaneous and K+-induced release of DA in Ca++-free medium. In addition, NT in 10(-4) M, but not in lower concentrations tested, potentiated the spontaneous, Ca++-dependent release of DA. It is suggested that the effect of NT on DA release is mediated by the specific NT receptors at the DA axonal terminals. The possibility, however, that NT has some influence on the carrier-mediated process of the membrane might not be ruled out.  相似文献   

19.
We describe here a sensitive assay method for lysosulfatide (sulfogalactosylsphingosine) in human tissues using HPLC. The method involves extraction of lipids, saponification, isolation using a C18 Sep-Pak column, derivatization with o-phthalaldehyde, and detection of the fluorescent lysosulfatide using HPLC. In control subjects, a small amount of lysosulfatide was detected in the cerebral white matter (9-35 pmol/mg of protein), spinal cord (35 pmol/mg of protein), sciatic nerve (14 pmol/mg of protein), and kidney (approximately 2 pmol/mg of protein) but not in the cerebral gray matter and liver. A marked accumulation of the lipid was noted in tissues from six patients with metachromatic leukodystrophy (MLD). The concentration of lysosulfatide was high in the cerebral white matter, spinal cord, and sciatic nerve (223-1,172 pmol/mg of protein). Even in the cerebral gray matter, kidney, and liver, where lysosulfatide was hardly detected in the control sample, a considerable amount (3-45 pmol/mg of protein) accumulated in MLD patients. The concentration and distribution pattern of lysosulfatide were similar to those of galactosylsphingosine (psychosine) accumulated in patients with Krabbe disease. Therefore, the accumulation of lysosulfatide may explain the demyelination in patients with MLD, as is the case with Krabbe disease.  相似文献   

20.
Valproyl taurinamides are a novel group of compounds that possess anticonvulsant activity. In this study a gas chromatographic micromethod was developed for the quantification of selected valproyl taurinamides and some of their metabolites in biological samples. Valproyl taurinamide (VTD), N-methyl valproyl taurinamide (M-VTD), N,N-dimethyl valproyl taurinamide (DM-VTD) and N-isopropyl valproyl taurinamide (I-VTD) were analyzed in mouse and dog plasma and in dog urine using gas chromatography. Flame ionization detection and mass spectrometric detection were compared. The plasma samples were prepared by solid-phase extraction using C(18) cartridges. The urine samples were prepared by liquid-liquid extraction. The sample volume used was 100 microl of dog plasma, 50 microl of mouse plasma and 20 microl of dog or mouse urine. The quantification range of the method was 1.5-50 mg/l in dog plasma (VTD only), 2.5-250 mg/l in mouse plasma (0.7-90 pmol injected) and 0.04-2 mg/ml in dog urine (VTD only). The inter-day precision in plasma and urine samples was around 10% for all quantified concentrations except LOQ (15-20%). The accuracy for all four compounds was between 90 and 110% within the entire concentration range. The developed method was suitable for quantification of a series of CNS-active valproyl taurineamide derivatives in biological samples at relevant in vivo concentrations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号