首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The marriage of computerized tomographic (CT) scanning and stereotactic surgery opens up new technical possibilities, as it becomes feasible to introduce a probe into any lesion which is identified on a CT scan. The various CT stereotactic techniques are reviewed, and generally involve four variations. The head holder of a standard stereotactic apparatus can be adapted to the CT scanner to interdigitate the coordinates of both devices in a known relationship. Second, some types of CT scanners allow the visualization of the vertical coordinate. Third, a stereotactic microdrive can be incorporated into the scanner. Finally, a simple aiming device can be attached to the patient's head and repeated scans taken as the probe is advanced to the target. Various authors have reported the use of techniques for biopsy, aspiration of cysts or hematomas, insertion of radioisotopes, or as an adjunct to open surgery.  相似文献   

2.
A new apparatus for CT-guided stereotactic surgery   总被引:1,自引:0,他引:1  
Combining whole-body CT scan with a stereotactic system, the authors have developed and applied clinically an apparatus which readily provides intraoperative CT images, making it possible to confirm the location of the target point and ascertain the intraoperative environment. It takes about 9 s to obtain a CT image. Our purpose is to make stereotactic surgery, a kind of blind surgery, as safe and reliable as a visualized procedure by intraoperative CT scanning. By the method, in which there is very little invasion under local anesthesia, evacuation of deep-seated intracerebral hematomas as well as brain abscesses and also biopsy or brachytherapy of brain tumors in the brain can be done with safety and reliability.  相似文献   

3.
目的介绍一种用于实验动物手术、立体定向给药、PET、核磁共振、CT、电生理检测等操作的多功能实验操作平台。方法采用高强度的有机玻璃板、有机玻璃棒和尼龙棒等工程塑料制作多功能实验操作平台,在该装置的固定下,完成各种实验动物手术、立体定向给药、PET、磁共振成像、CT、电生理检测等操作。结果用该操作平台实验动物得到了稳妥固定、精确定位,并实现各项实验指标的无失真的观测。结论该操作平台设计合理、使用简单、功能多样,是一种良好的实验动物操作平台。  相似文献   

4.
CT-guided ablative stereotaxis without ventriculography   总被引:1,自引:0,他引:1  
A new technique is described which permits all types of stereotactic surgery to be done without ventriculography, with CT guidance only. The present series consists of 42 patients who underwent thalamotomy, posteromedial hypothalamotomy, dentatotomy or anterior capsulotomy for movement disorders, chronic pain, spasmodic torticollis or psychiatric illness. Postoperative lesion control with repeated CT showed that the method was accurate. The clinical results were considered to be better than those after previous ventriculography-guided surgery. It is concluded that ventriculography is no longer needed for stereotactic neurosurgery.  相似文献   

5.
The conventional Sugita stereotactic frame has been improved to perform CT-guided stereotactic surgery both in the CT and operating rooms. The development of our instrument and the software of the scanners' computer are presented. Newly designed equipment produced almost no artifacts on the CT image. Using the improved stereotactic frame, we have operated upon 44 intracerebral hematomas in the CT room. More than 80% of the cases had satisfactory results. Two complications were encountered, and 1 patient died from pneumonia. Our initial experience of the pre- and postoperative cerebral blood flow measurement with 133Xe inhalation method and single photon emission CT is described.  相似文献   

6.
While target localization for human stereotactic surgery has been refined by computed tomographic (CT) and magnetic resonance imaging (MRI), stereotaxis in experimental animals has remained dependent upon external cranial landmarks and standardized atlas coordinates. To overcome the limitations and inaccuracies of animal devices using the original Horsley-Clarke method, we modified a standard animal stereotactic instrument in order to make target localization and coordinate determination possible with CT imaging. Although the device can be adapted to any medium-sized animal species, we demonstrate its use with dogs here.  相似文献   

7.
This report describes a system for incorporation of stereotactic CT scanning data, stereotactic arteriographic data and a computer-generated stereotactic atlas into a three-dimensional matrix utilizing an operating room computer. 86 patients have undergone computer-assisted stereotactic biopsies of intracranial lesions without mortality or neurologic morbidity. Neuroablative and neuroaugmentative procedures have been performed on 5 patients using the CT stereotactic atlas with good correlation with target points determined by ventriculography and microelectrode recording.  相似文献   

8.
Experience using two CT-guided stereotactic biopsy methods   总被引:1,自引:0,他引:1  
15 patients had intracranial CT-guided stereotactic biopsies. Biopsies were performed either with a Riechert-Mundinger stereotactic frame modified for use in the CT or by using the CT scan to establish the relationship of the intracranial lesion to identifiable bony landmarks, and subsequently performing the biopsy in a standard stereotactic frame. Both systems provided safe and accurate methods for obtaining intracranial tissue.  相似文献   

9.
The Brown-Roberts-Wells (BRW) stereotactic unit has proven itself to be a highly accurate instrument for biopsying or locating pathologic intracranial lesions based on CT scan information. We utilized the BRW frame to select 18 target sites in 12 patients undergoing functional stereotactic procedures. Two patients had bilateral cingulumotomies, 5 had thalamotomies for movement disorders, and 5 underwent electrode implantations for the treatment of chronic pain. Stereotactic frame settings were determined using a positive contrast ventriculogram, orthogonal radiographs, and a computer program provided with the BRW system. In addition, attempts were made to select targets based on CT scan landmarks alone, and these were compared to those derived using ventriculography. We found the BRW frame to be a satisfactory device for performing functional neurosurgical procedures based on ventriculographic landmarks. Coordinates derived from CT scans were similar to those obtained with ventriculography, but were not accurate enough to permit the use of CT scanning as the sole means of target identification. Although future improvements in imaging techniques and computer software are likely to occur, our experience supports ventriculography as the current method of choice for the precise localization of functional targets with the BRW stereotactic system.  相似文献   

10.
By means of new plastic stereotactic ring and head fixers, stereotactic procedures can be combined with MRI, with stereotactic coordinates obtained from the MRI images. The method was rechecked against CT stereotaxy and shows a good correspondence of the target coordinates. With MRI stereotaxy, structures near bony regions will be more accessible than with CT stereotaxy. Moreover, the MRI procedure seems to have advantages for functional therapy without the necessity of contrast ventriculography.  相似文献   

11.
Magnetic resonance imaging (MRI) offers significant advantages over computerized tomography (CT) and teleradiographic techniques when used for the evaluation and management of epilepsy and functional neurological disorders. Depth recording and radiofrequency electrodes can be more accurately positioned within structures such as the amygdala and hippocampus. The extent of corpus callosum section, lobectomy, topectomy, and radiofrequency stereotactic lesions can now be readily confirmed and related with seizure, neurological, and behavioral outcome. Occult, usually low grade, intraparenchymal neoplasms not visualized on CT scans can be located by MRI and biopsied or excised by MRI stereotactic techniques.  相似文献   

12.

Background

The therapeutic efficacy of stereotactic radiosurgery for glioblastoma is not well understood, and there needs to be an effective biomarker to identify patients who might benefit from this treatment. This study investigated the efficacy of computed tomography (CT) perfusion imaging as an early imaging biomarker of response to stereotactic radiosurgery in a malignant rat glioma model.

Methods

Rats with orthotopic C6 glioma tumors received either mock irradiation (controls, N = 8) or stereotactic radiosurgery (N = 25, 12 Gy in one fraction) delivered by Helical Tomotherapy. Twelve irradiated animals were sacrificed four days after stereotactic radiosurgery to assess acute CT perfusion and histological changes, and 13 irradiated animals were used to study survival. Irradiated animals with survival >15 days were designated as responders while those with survival ≤15 days were non-responders. Longitudinal CT perfusion imaging was performed at baseline and regularly for eight weeks post-baseline.

Results

Early signs of radiation-induced injury were observed on histology. There was an overall survival benefit following stereotactic radiosurgery when compared to the controls (log-rank P<0.04). Responders to stereotactic radiosurgery showed lower relative blood volume (rBV), and permeability-surface area (PS) product on day 7 post-stereotactic radiosurgery when compared to controls and non-responders (P<0.05). rBV and PS on day 7 showed correlations with overall survival (P<0.05), and were predictive of survival with 92% accuracy.

Conclusions

Response to stereotactic radiosurgery was heterogeneous, and early selection of responders and non-responders was possible using CT perfusion imaging. Validation of CT perfusion indices for response assessment is necessary before clinical implementation.  相似文献   

13.
A definitive pathoanatomic diagnosis was achieved in 14 biopsies of deep cerebral tumors in which the Laitinen CT adapter was utilized. In 5 patients, a third-ventricular colloid cyst was aspirated or resected by stereotactic endoscopy, with excellent results after a mean follow-up time of 2.5 years. Several instruments, including a diagnostic ultrasound probe, an ultrasonic aspirator, a combination laser and an endoscope can be used stereotactically when mounted on a special instrument carrier. Integration of the Laitinen stereotactic device and the CT adapter was developed to allow noninvasive stereotactic radiotherapy in a conventional fractionation schedule by a standard linear accelerator. Technical experiences using this radiosurgical system in over 30 sessions for treating inoperable cerebral arteriovenous malformations are promising, but the follow-up time is too short for evaluating the clinical effect.  相似文献   

14.
A computer graphics technique for computer-assisted stereotactic surgery is presented. The program is designed to aid the surgeon by presenting an on-line graphics display of stereotactic probes and electrodes superimposed on cross sections of the human brain stem. This technique simulates an otherwise blind surgical procedure on a graphics screen for use during surgery. An earlier system based around the DEC MINC-11 BA computer system has been used by the authors for the performance of stereotactic surgery with conventional ventriculography. This system has been upgraded and is now configured about an even more compact microprocessor-based hardware system with expanded graphics capabilities, which also allows its use with computerized tomography.  相似文献   

15.
A technique to apply reconstructed X-ray computed tomography (CT) and magnetic resonance imaging (MRI) for target determination in stereotactic Bragg peak proton beam therapy of intracranial lesions was developed. Twenty-one benign intracranial tumors and vascular abnormalities were managed using this technique. Clinical features of these lesions, as well as targeting problems associated with the MRI and CT image interpretation, are presented.  相似文献   

16.
The new stereotactic instrument has the advantages of use with computerized tomography (CT) or magnetic resonance imaging (MRI) without special adaptations of instruments, brain targets transferred directly from CT or MRI to apparatus, and use with conventional stereotactic techniques. The apparatus is designed to meet present demands of neurosurgical facilities of good standards and capabilities, encompassing present and future developments towards more efficient and less invasive brain operations.  相似文献   

17.
Twelve patients with recurrent supratentorial gliomas were treated with implanted 125I seeds. The interval from initial surgery to interstitial radiation ranged from 3 months to 9 years. The techniques for brachytherapy included volume implantation by craniotomy in one, stereotactic implantation with low-activity seeds in 7 and high-activity seeds in 4 patients. The total dose received ranged from 5,500 to 27,000 cGy. CT scans performed sequentially on all patients showed progressive attenuation in areas previously enhancing, suggestive of tumor necrosis produced by the interstitial sources. The mean and median survival of these patients was 23 and 22 weeks, with the 4 most recent patients still alive.  相似文献   

18.
螺旋CT三维重建技术在胫骨平台骨折的诊疗应用分析   总被引:1,自引:0,他引:1  
目的探讨螺旋CT三维重建在胫骨平台骨折中的临床应用。方法回顾性分析2007-2008年55例胫骨平台骨折病例.手术前均常规行X线摄片,行螺旋CT三维重建并与术中所见对照。结果所有病例螺旋CT三维重建明确地显示了骨折,并在骨折的分型和关节面碎裂情况的描述上较平片优越,与手术中所见一致。结论CT多种成像后处理技术可清晰显示骨折的部位、骨折线的走行方向、骨质碎裂程度和移位的距离以及关节面塌陷情况等,对术前分型、制订手术治疗方案具有重要的参考价值。  相似文献   

19.
目的:分析CT引导下立体定向射频热凝三叉神经半月节对原发性三叉神经痛的疗效,探讨其临床适用性。方法:选择从2011年5月至2012年12月于我院住院治疗原发性三叉神经痛的58例患者,在三维CT引导下采用通过BrainLAB手术计划系统经前入路卵圆孔穿刺三叉神经半月神经节,术中根据疼痛分布范围射频热凝三叉神经半月节。观察并比较治疗前后的VAS评分,临床疗效,术中和术后不良反应情况。结果:58例患者的穿刺手术均成功,术后1d、3d、6d的VAS评分均较治疗前显著降低(P〈0.01);1周后58例患者中,有53例患者疼痛完全消失,l例患者偶然出现疼痛,但无需服用药物处理,共显效54例;4例患者疼痛有所减轻或疼痛发作频率降低,但仍需服用药物,或服用药物剂量较治疗前明显减少;疼痛无改善或者非用药不能缓解的持续痛仅1例。总有效例数为57例,总有效率达98.26%。术中发生不良反应6例,在术后均有所缓解。术后发生各种并发症共15例,均未明显影响手术效果。结论:CT引导可以较为准确的进入穿刺部位,使立体定向射频热凝三叉神经半月节手术更加顺利,达到治疗原发性三叉神经痛的理想效果,适合临床长期推广应用。  相似文献   

20.
PurposeImage-guided radiotherapy (IGRT) based on bone matching can produce large target-positioning errors because of expiration breath-hold reproducibility during stereotactic body radiation therapy (SBRT) for liver tumors. Therefore, the feasibility of diaphragm-based 3D image matching between planning computed tomography (CT) and pretreatment cone-beam CT was investigated.MethodsIn 59 liver SBRT cases, Lipiodol uptake after transarterial chemoembolization was defined as a tumor marker. Further, the relative isocenter coordinate that was obtained by Lipiodol matching was defined as the reference coordinate. The distance between the relative isocenter coordinate and reference coordinate, which was obtained from diaphragm matching and bone matching techniques, was defined as the target positioning error. Furthermore, the target positioning error between liver matching and Lipiodol matching was evaluated.ResultsThe positioning errors in all directions by the diaphragm matching were significantly smaller than those obtained by using by the bone matching technique (p < 0.05). Further, the positioning errors in the A-P and C-C directions that were obtained by using liver matching were significantly smaller than those obtained by using bone matching (p < 0.05). The estimated PTV margins calculated by the formula proposed by van Herk for diaphragm matching, liver matching, and bone matching were 5.0 mm, 5.0 mm, and 11.6 mm in the C-C direction; 3.6 mm, 2.4 mm, and 6.9 mm in the A-P direction; and 2.6 mm, 4.1 mm, and 4.6 mm in the L-R direction, respectively.ConclusionsDiaphragm matching-based IGRT may be an alternative image matching technique for determining liver tumor positions in patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号