首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Law H  Lau Y 《Cytometry》2001,43(2):150-153
BACKGROUND: Telomeres are highly conserved repeats at the ends of chromosomes that maintain chromosome stability and reflect the replicative potential of cells. Telomere length can be determined by Southern blot hybridization or quantitative fluorescence in situ hybridization (Q-FISH). Recently, two flow cytometry-based (Flow) FISH protocols have been published. METHODS: We compared the telomere length measured by Southern blotting and Flow FISH using standard beads to calibrate and quantify the fluorescence intensity. RESULTS: The telomeric fluorescence of cord blood and peripheral blood mononuclear cells was similar to that reported by other studies. There was a linear relationship between the telomeric fluorescence determined by Flow FISH and the telomere fragment size determined by Southern blotting (r = 0.89; P < 0.001). CONCLUSION: It is important to set up a center-specific curve and select appropriate cell lines for reference. This Q-Flow FISH protocol will facilitate the measurement of telomere length and allow more meaningful comparison of data (in standard fluorescence units or fragment size) between institutes.  相似文献   

2.
Telomeres are physical ends of mammalian chromosomes that dynamically change during the lifetime of a cell or organism. In order to understand mechanisms responsible for telomere dynamics, it is necessary to develop methods for accurate telomere length measurement. The most sensitive method for measuring telomere length in mouse chromosomes is quantitative fluorescence in situ hybridization (Q-FISH). The usual protocol for Q-FISH requires plasmids with variable numbers of telomeric repeats and fluorescence beads as calibration standards. Here, we describe a Q-FISH protocol in which two mouse lymphoma cell lines with well-defined telomere lengths are used as calibration standards. Using this protocol we demonstrate that reproducible results can be obtained in a set of four different mouse cell lines. This method can be adapted so that any pair of mammalian cell lines can serve as an internal calibration standard.  相似文献   

3.
To benefit from the fluorescence-based automatic microscope (FLAME), we have adapted a PNA FISH technique to automatically determine telomere length in interphase nuclei. The method relies on the simultaneous acquisition of pan-telomeric signals and reference probe signals. We compared the quantitative figures to those for existing methods, i.e. Southern blot analysis and quantitative FISH (Q-FISH). Quantitative-FISH on interphase nuclei (IQ-FISH) allows the exact quantification of telomere length in interphase nuclei. Thus, this enables us to obtain not only exact information on the telomere length, but also morphological and topological details. The automatic measurement of large cell numbers allows the measurement of statistically relevant cell populations.  相似文献   

4.
Ji  Guangzhen  Liu  Kai  Okuka  Maja  Liu  Na  Liu  Lin 《BMC cell biology》2012,13(1):1-11
Telomeres are essential for the maintenance of genomic stability, and telomere dysfunction leads to cellular senescence, carcinogenesis, aging, and age-related diseases in humans. Pigs have become increasingly important large animal models for preclinical tests and study of human diseases, and also may provide xeno-transplantation sources. Thus far, Southern blot analysis has been used to estimate average telomere lengths in pigs. Telomere quantitative fluorescence in situ hybridization (Q-FISH), however, can reveal status of individual telomeres in fewer cells, in addition to quantifying relative telomere lengths, and has been commonly used for study of telomere function of mouse and human cells. We attempted to investigate telomere characteristics of porcine cells using telomere Q-FISH method. The average telomere lengths in porcine cells measured by Q-FISH correlated with those of quantitative real-time PCR method (qPCR) or telomere restriction fragments (TRFs) by Southern blot analysis. Unexpectedly, we found that porcine cells exhibited high incidence of telomere doublets revealed by Q-FISH method, coincided with increased frequency of cellular senescence. Also, telomeres shortened during subculture of various porcine primary cell types. Interestingly, the high frequency of porcine telomere doublets and telomere loss was associated with telomere dysfunction-induced foci (TIFs). The incidence of TIFs, telomere doublets and telomere loss increased with telomere shortening and cellular senescence during subculture. Q-FISH method using telomere PNA probe is particularly useful for characterization of porcine telomeres. Porcine cells exhibit high frequency of telomere instability and are susceptible to telomere damage and replicative senescence.  相似文献   

5.
目的:应用定量荧光原位杂交(Q-FISH)方法测定端粒长度。方法:选取4种端粒长度均一的标准细胞株采用Q-FISH的方法做出荧光亮度与端粒长度的标准曲线,从而得出实验细胞株的端粒长度,与DNA印迹法测定末端限制性片段(TRF)长度进行二者之间的相关性分析。结果:检测荧光强度的最佳线性曝光时间为400ms,相对于DNA印迹法,定量荧光原位杂交(Q-FISH)法所需标本量少,实验周期短,端粒长度结果与Southern杂交法具有很好的相关性。结论:采用定量荧光原位杂交方法测端粒长度具有重复性好、精确可靠的特点,适用于对珍贵标本的端粒改变进行分析。  相似文献   

6.
We report here the results of a telomere length analysis in four male Chinese hamsters by quantitative fluorescence in situ hybridization (Q-FISH). We were able to measure telomere length of 64 (73%) of 88 Chinese hamster telomeres. We could not measure telomere length in chromosome 10 or in the short arms of chromosomes 5, 6, 7 and 8 because of the overlaps between the interstitial and terminal telomeric signals. Our analysis in the 73% of Chinese hamster telomeres indicate that their average length is approximately 38 kb. Therefore, Chinese hamster telomeres are comparable in length to mouse telomeres, but are much longer than human telomeres. Similar to previous Q-FISH studies on human and mouse chromosomes, our results indicate that individual Chinese hamster chromosomes may have specific telomere lengths, suggesting that chromosome-specific factors may be involved in telomere length regulation.  相似文献   

7.
We have reported that telomere fluorescence units (TFUs) of established induced pluripotent stem cells (iPSCs) derived from human amnion (hAM933) and fetal lung fibroblasts (MRC-5) were significantly longer than those of the parental cells, and that the telomere extension rates varied quite significantly among clones without chromosomal instability, although the telomeres of other iPSCs derived from MRC-5 became shorter as the number of passages increased along with chromosomal abnormalities from an early stage. In the present study we attempted to clarify telomere dynamics in each individual chromosomal arm of parental cells and their derived clonal human iPSCs at different numbers of passages using quantitative fluorescence in situ hybridization (Q-FISH). Although no speci?c arm of any particular chromosome appeared to be consistently shorter or longer than most of the other chromosomes in any of the cell strains, telomere elongation in each chromosome of an iPSC appeared to be random and stochastic. However, in terms of the whole genome of any specific cell, the telomeres showed overall elongation associated with iPSC generation. We have thus demonstrated the specific telomere dynamics of each individual chromosomal arm in iPSCs derived from parental cells, and in the parental cells themselves, using Q-FISH.  相似文献   

8.
Studies of telomeres and telomere biology often critically rely on the detection of telomeric DNA and measurements of the length of telomere repeats in either single cells or populations of cells. Several methods are available that provide this type of information and it is often not clear what method is most appropriate to address a specific research question. The major variables that need to be considered are the material that is or can be made available and the accuracy of measurements that is required. The goal of this review is to provide a comprehensive summary of the most commonly used methods and discuss the advantages and disadvantages of each. Methods that start with genomic DNA include telomere restriction fragment (TRF) length analysis, PCR amplification of telomere repeats relative to a single copy gene by Q-PCR or MMQPCR and single telomere length analysis (STELA), a PCR-based approach that accurately measures the full spectrum of telomere lengths from individual chromosomes. A different set of methods relies on fluorescent in situ hybridization (FISH) to detect telomere repeats in individual cells or chromosomes. By including essential calibration steps and appropriate controls these methods can be used to measure telomere repeat length or content in chromosomes and cells. Such methods include quantitative FISH (Q-FISH) and flow FISH which are based on digital microscopy and flow cytometry, respectively. Here the basic principles of various telomere length measurement methods are described and their strengths and weaknesses are highlighted. Some recent developments in telomere length analysis are also discussed. The information in this review should facilitate the selection of the most suitable method to address specific research question about telomeres in either model organisms or human subjects.  相似文献   

9.
Using quantitative fluorescence in situ hybridization (Q-FISH), the average telomere length of hepatoma cells was assessed by the average telomeric signal intensity of cancer cells relative to that of stromal cells. We demonstrated first the applicability of Q-FISH for tissue sections by comparing Q-FISH and Southern blotting results. Tumors less than 50mm in diameter and with a relative telomeric intensity of less than 0.6 were categorized as group A and the remainder as group B. In group A, the telomere length correlated negatively with tumor size, whereas in group B there was no correlation. Compared with the group A tumors, the group B tumors were of significantly more advanced stage, showed higher telomerase and proliferative activities, and exhibited less differentiated histology. Therefore, we considered that a lack of correlation between telomere length and tumor size, namely, size-independence of telomere length, is associated with unfavorable clinicopathological features of hepatocellular carcinomas.  相似文献   

10.
Individuals with trisomy 21 have an increased risk of developing leukemia and premature dementia. They also have a higher rate of telomere loss. The aim of the study was to compare telomere length and the hTERC gene copy number, which encodes the telomerase RNA subunit, in amniocytes of trisomy 21 conceptions and normal pregnancies. A quantitative fluorescence-in-situ protocol (Q-FISH) was used to compare telomere length in amniocytes cultured from 11 trisomy 21 conceptions and from 14 normal pregnancies. Quantification was conducted using novel computer software. Fluorescence in situ hybridization (FISH) was used to assess the percentage of cells with additional copies of hTERC. We found that the immunofluorescence intensity, which represents telomere length, was significantly lower in amniocytes from trisomy 21 conceptions compared to the control group. The trisomy 21 group had a higher number of cells with additional copies of hTERC. This observation could be one of the cytogenetic parameters that represent a state of genetic instability and might play a role in the pathomechanism of typical features of Down syndrome, such as dementia and malignancy.  相似文献   

11.
BACKGROUND: Telomeres containing noncoding DNA repeats at the end of the chromosomes are essential for chromosomal stability and are implicated in regulating the replication and senescence of cells. The gradual loss of telomere repeats in cells has been linked to aging and tumor development and methods to measure telomere length are of increasing interest. At least three methods for measuring the length of telomere repeats have been described: Southern blot analysis and quantitative fluorescence in situ hybridization using either digital fluorescence microscopy (Q-FISH) or flow cytometry (flow-FISH). Both Southern blot analysis and Q-FISH have specific limitations and are time-consuming, whereas the flow-FISH technique requires relatively few cells (10(5)) and can be completed in a single day. A further advantage of the flow-FISH method is that data on the telomere length from individual cells and subsets of cells (lymphocytes and granulocytes) can be acquired from the same sample. In order to obtain accurate and reproducible results using the flow-FISH technique, we systematically explored the influence of various steps in the protocol on telomere length values and established an acceptable range for the most critical parameters. METHODS: Isolated leukocytes from whole blood are denatured by heat and 70%/75% formamide, then hybridized with or without a telomere-specific fluorescein isothiocyante (FITC)-conjugated peptide nucleic acid probe (PNA). Unbound telomere PNA is washed away, the DNA is counterstained, and telomere fluorescence is measured on a flow cytometer using an argon ion laser (488 nm) to excite FITC. For each sample, duplicates of telomere PNA-stained and unstained tubes are analyzed. RESULTS: Cell counts and flow-FISH telomere length measurements were performed on leukocytes and thymocytes of humans and other species. Leukocyte suspensions were prepared by two red blood cell lysis steps with ammonium chloride. Optimal denaturation of DNA was achieved by heating at 85-87 degrees C for 15 min in a solution containing 70%/75% formamide. Hybridization was performed at room temperature with a 0.3 microg/ml telomere-PNA probe for at least 60-90 min. Unbound telomere-PNA probe was diluted at least 4,000-40,000 times with wash steps containing 70%/75% formamide at room temperature. LDS 751 and DAPI were suitable as DNA counterstains as they did not show significant interference with telomere length measurement. CONCLUSIONS: The use of flow-FISH for telomere length measurements in nucleated blood cells requires tight adherence to an optimized protocol. The method described here can be used to determine rapidly the telomere length in subsets of nucleated blood cells.  相似文献   

12.
Determination of telomere length is traditionally performed by Southern blotting and densitometry, giving a mean telomere restriction fragment (TRF) value for the total cell population studied. Fluorescence in situ hybridization (FISH) of telomere repeats has been used to calculate telomere length, a method called quantitative (Q)-FISH. We here present a quantitative flow cytometric approach, Q-FISHFCM, for evaluation of telomere length distribution in individual cells based on in situ hybridization using a fluorescein-labeled peptide nucleic acid (PNA) (CCCTAA)3probe and DNA staining with propidium iodide. A simple and rapid protocol with results within 30 h was developed giving high reproducibility. One important feature of the protocol was the use of an internal cell line control, giving an automatic compensation for potential differences in the hybridization steps. This protocol was tested successfully on cell lines and clinical samples from bone marrow, blood, lymph nodes and tonsils. A significant correlation was found between Southern blotting and Q-FISHFCMtelomere length values ( P = 0.002). The mean sub-telomeric DNA length of the tested cell lines and clinical samples was estimated to be 3.2 kbp. With the Q-FISHFCMmethod the fluorescence signal could be determined in different cell cycle phases, indicating that in human cells the vast majority of telomeric DNA is replicated early in S phase.  相似文献   

13.
Regulation of telomere length maintenance and capping are a critical cell functions in both normal and tumor cells. Tankyrase 2 (Tnks2) is a poly(ADP-ribose) polymerase (PARP) that has been shown to modify itself and TRF1, a telomere-binding protein. We show here by overexpression studies that tankyrase 2, like its closely related homolog tankyrase 1, can function as a positive regulator of telomere length in human cells, dependent on its catalytic PARP activity. To study the role of Tnks2 in vivo, we generated mice with the Tnks2 PARP domain deleted. These mice are viable and fertile but display a growth retardation phenotype. Telomere analysis by quantitative fluorescence in situ hybridization (FISH), flow-FISH, and restriction fragment analysis showed no change in telomere length or telomere capping in these mice. To determine the requirement for Tnks2 in long-term maintenance of telomeres, we generated embryonic stem cells with the Tnks2 PARP domain deleted and observed no change, even upon prolonged growth, in telomere length or telomere capping. Together, these results suggest that Tnks2 has a role in normal growth and development but is not essential for telomere length maintenance or telomere capping in mice.  相似文献   

14.
Elongated telomeres in scid mice   总被引:9,自引:0,他引:9  
Severe combined immunodeficiency (scid) mice are deficient in the enzyme DNA-PK (DNA-dependent protein kinase) as a result of the mutation in the gene encoding the catalytic subunit (DNA-PKcs) of this enzyme. DNA-PKcs is a member of the phosphatidylinositol 3-kinase superfamily, which includes the human protein ATM (ataxia telangiectasia mutated) and the yeast protein Tel1. Using Q-FISH (quantitative fluorescence in situ hybridization), we show here that scid mice from four different genetic backgrounds have, on average, 1.5-2 times longer telomeres than those of corresponding wild-type mice. Our results point to the possibility that DNA-PKcs may, directly or indirectly, be involved in telomere length regulation in mammalian cells.  相似文献   

15.
Telomere length measurements using digital fluorescence microscopy.   总被引:11,自引:0,他引:11  
BACKGROUND: The ends of chromosomes (telomeres) are important to maintain chromosome stability, and the loss of telomere repeat sequences has been implicated in cellular senescence and genomic instability of cancer cells. The traditional method for measuring the length of telomeres (Southern analysis) requires a large number of cells (>10(5)) and does not provide information on the telomere length of individual chromosomes. Here, we describe a digital image microscopy system for measurements of the fluorescence intensity derived from telomere repeat sequences in metaphase cells following quantitative fluorescence in situ hybridization (Q-FISH). METHODS: Samples are prepared for microscopy using Q-FISH with Cy3 labeled peptide nucleic acid probes specific for (T(2)AG(3))(n) sequences and the DNA dye DAPI. Separate images of Cy3 and DAPI fluorescence are acquired and processed with a dedicated computer program (TFL-TELO). With the program, the integrated fluorescence intensity value for each telomere, which is proportional to the number of hybridized probes, is calculated and presented to the user. RESULTS: Indirect tests of our method were performed using simulated as well as defined tests objects. The precision and consistency of human telomere length measurements was then analyzed in a number of experiments. It was found that by averaging the results of less than 30 cells, a good indication of the telomere length (SD of 10-15%) can be obtained. CONCLUSIONS: We demonstrate that accurate and repeatable fluorescence intensity measurements can be made from Q-FISH images that provide information on the length of telomere repeats at individual chromosomes from limited number of cells.  相似文献   

16.
Telomeres have emerged as crucial cellular elements in aging and various diseases including cancer. To measure the average length of telomere repeats in cells, we describe our protocols that use fluorescent in situ hybridization (FISH) with labeled peptide nucleic acid (PNA) probes specific for telomere repeats in combination with fluorescence measurements by flow cytometry (flow FISH). Flow FISH analysis can be performed using commercially available flow cytometers, and has the unique advantage over other methods for measuring telomere length of providing multi-parameter information on the length of telomere repeats in thousands of individual cells. The accuracy and reproducibility of the measurements is augmented by the automation of most pipetting (aspiration and dispensing) steps, and by including an internal standard (control cells) with a known telomere length in every tube. The basic protocol for the analysis of nucleated blood cells from 22 different individuals takes about 12 h spread over 2-3 days.  相似文献   

17.
BACKGROUND: The length of the terminal sequences of linear chromosomes changes dynamically during cellular proliferation. A crucial element in the study of telomere-related regulation mechanisms is the ability to measure telomere lengths of individual chromosomes. Individual telomere lengths can be measured using digital imaging fluorescence microscopy-based techniques. We extended this method using confocal microscopy for the acquisition of three-dimensional (3D) images. Consequently, variations in measured signal intensities due to erroneous focusing are avoided. METHODS: We employed our 3D telomere sizing method to compare telomere lengths of sister chromatids within metaphase preparations from human lymphocytes. The samples were treated following a quantitative fluorescence in situ hybridization (Q-FISH) protocol using fluorescein isothiocyanate (FITC)-labeled telomeric peptidic nucleic acid (PNA) probes and propidium iodide (PI) counterstain. RESULTS: We demonstrated that the telomere lengths of two sister chromatids are not necessarily equal in human lymphocytes. Profound statistical analysis demonstrated significant differences in the distribution of the sister chromatid telomere lengths, but we were not able to prove a discrete distribution of telomere sister ratios. These telomere length differences were more apparent in older individuals. CONCLUSION: Whereas the majority of sister telomere pairs have equal lengths, surprisingly, a minority was significantly different in each individual studied. We are convinced that these observations are not linked to the methodology or the protocol applied. We suggest that a biological phenomenon might be involved.  相似文献   

18.
BACKGROUND: Various protocols for estimation of telomere length in individual cells by flow cytometry using fluorescence in situ hybridization of fluorescently labeled peptide nucleic acid (PNA) probes (Flow-FISH) have been described. Combined analysis of telomere length and cell phenotype, however, remains difficult because few fluorochromes with suitable emission spectra tolerate the harsh conditions needed for DNA denaturation during hybridization of the telomere-specific PNA probe. We overcame these problems and developed a method for measuring telomere length in cell subsets characterized by the expression of two surface antigens. METHODS: Alexa Fluor 488 and Alexa Fluor 546 were used for cell surface staining. Antigen-antibody complexes were covalently cross-linked onto the cell membrane before Flow-FISH. Cells were hybridized with a PNA probe conjugated to cyanine 5 (Cy5). Hoechst 33342 (HO342) was added for determination of cellular DNA content. For assay standardization, we added an aliquot of a single batch of 1,301 cells to each sample as an internal control before hybridization with the PNA probe. Samples were prepared in duplicate and analyzed on a standard three-laser BD LSR flow cytometer. For assay validation, the same samples were analyzed in parallel to correlate the percentage of telomere length of the sample versus 1,301 control cells to the mean size of terminal restriction fragments (TRFs) of DNA as determined by Southern gel analysis. RESULTS: The method permitted clear identification of lymphocyte subsets in samples hybridized for Flow-FISH, with subset frequencies comparable to those of untreated samples. At a concentration of 10 nM, the Cy5-labeled telomere-specific PNA probe produced a bright fluorescence signal well separated from background. Addition of HO342 in low concentration did not interfere with Cy5 telomere fluorescence, produced adequate DNA histograms, and permitted clear identification of cell phenotype. The probe concentration of 10 nM also proved optimal for inclusion of 1,301 control cells for assay standardization. Telomere length estimations by the current method correlated highly with TRF calculations by Southern gel hybridization (r(2)= 0.9, P = 0.0003). Application of our protocol to the analysis of human CD8CD28 lymphocyte subsets showed that CD8(+bright)CD28(-) lymphocytes generally exhibit shorter telomeres than CD8(+bright)CD28(+) cells. These data concurred with previous results of telomere shortening in CD8(+)CD28(-) T cells that were obtained by using different techniques. CONCLUSIONS: The multiparameter Flow-FISH protocol permitted rapid determination of differences in telomere length in subpopulations characterized by two surface markers without prior cell separation.  相似文献   

19.
Telomere instability in a human cancer cell line.   总被引:6,自引:0,他引:6  
Telomere maintenance is essential in immortal cancer cells to compensate for DNA lost from the ends of chromosomes, to prevent chromosome fusion, and to facilitate chromosome segregation. However, the high rate of fusion of chromosomes near telomeres, termed telomere association, in many cancer cell lines has led to the proposal that some cancer cells may not efficiently perform telomere maintenance. Deficient telomere maintenance could play an important role in cancer because telomere associations and nondisjunction have been demonstrated to be mechanisms for genomic instability. To investigate this possibility, we have analyzed the telomeres of the human squamous cell carcinoma cell line SQ-9G, which has telomere associations in approximately 75% of the cells in the population. The absence of detectable telomeric repeat sequences at the sites of these telomere associations suggests that they result from telomere loss. The analysis of telomere length by quantitative in situ hybridization demonstrated that, compared to the human squamous cell carcinoma cell line SCC-61 which has few telomere associations, SQ-9G has more extensive heterogeneity in telomere length and more telomeres without detectable telomeric repeat sequences. The dynamics of the changes in telomere length also demonstrated a higher rate of fluctuation in telomere length, both on individual telomeres and coordinately on all telomeres. These results demonstrate that telomere maintenance can play a role in the genomic instability seen in cancer cells.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号