首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An integrated fluidized bed bioreactor (iFBBR) was designed to incorporate an aerobic sponge FBBR (ASB-FBBR) into an anoxic granular activated carbon FBBR (GAC-FBBR). This iFBBR was operated with and without adding a new starch based flocculant (NSBF) to treat synthetic primary treated sewage effluent (PTSE). The NSBF contains starch based cationic flocculants and trace nutrients. The results indicate that the iFBBR with NSBF addition could remove more than 93% dissolved organic carbon (DOC), 61% total nitrogen (T-N) and 60% total phosphorus (T-P) at just a very short hydraulic retention time of 50 min. The optimum frequency of adding NSBF to the iFFBR is four times per day. As a pretreatment to microfiltration, the iFFBR could increase 5 L/m2 h of critical flux thus reducing the membrane fouling. In addition, better microbial activity was also observed with high DO consumption (>66%) and specific oxygen uptake rate (>35 mg O2/g VSS h).  相似文献   

2.
A two-step anaerobic baffled reactor (ABR-1 and ABR-2) for H2 production from municipal food waste (MFW) was investigated at a temperature of 26 °C. In ABR-1, the average yield of H2 at an HRT of 26 h and OLR of 58 kg COD/m3 d was 250 ml H2/g VS removed. As unexpected; the H2 production in the ABR-2 was further increased up to 370 ml H2/gVS removed at a HRT of 26 h and OLR of 35 kgCOD/m3 d. The total H2 yield in the two-step process was estimated to be 4.9 mol H2/mol hexose. The major part of H2 production in the ABR-1 was due to the conversion of CODparticulate (36%). In the ABR-2 the H2 yield was mainly due to the conversion of COD in the soluble form (76%). Based on these results MFW could be ideal substrate for H2 production in a two-step ABR processes.  相似文献   

3.
Anaerobic treatment of wastewater from a selected seafood processing plant was conducted at organic loading rates (OLR) ranging from 0.3 to 1.8 kg chemical oxygen demand (COD)/m3.day and hydraulic retention times (HRT) ranging from 36 to 6 days. COD reduction decreased with increasing OLR. More than 75% COD reduction could be maintained up to an OLR of about 1 kg COD/m3.day with an HRT of 11 days. An OLR of 1.3 kg COD/m3.day corresponding to an HRT of 6.6 days gave maximal biogas productivity of 1.5 m3/m3.day or 1.3 m3 biogas/kg COD with a 65% COD reduction. If the HRT was kept constant at 11 days, an OLR of 1.3 kg COD/m3.day achieved maximal biogas productivity (1.1 m3/m3.day) and yield (0.75 m3/kg COD) and a 60% COD reduction for treatment of tuna condensate.P. Prasertsan and S. Jung are with the Department of Agro-Industry, Faculty of Natural Resources, Prince of Songkla University, Hatyai 90110, Thailand. K.A. Buckle is with the Department of Food Science and Technology, University of New South Wales, Kensington, NSW 2033, Australia.  相似文献   

4.
In this study, the performance of 5.4 L hybrid upflow anaerobic sludge blanket (HUASB) reactor for treating poultry slaughterhouse wastewater under mesophilic conditions (29-35 °C), was investigated. After starting-up, the reactor was loaded up to an OLR of 19 kg COD/m3 d and achieved varied TCOD and SCOD removal efficiencies of 70-86% and 80-92%, respectively. The biogas was varied between 1.1 and 5.2 m3/m3 d with the maximum methane content of 72%. The maximum methane yield was 0.32 m3/kg CODremoved at an OLR of 9.27 kg COD/m3 d. Black matured granules of size between 2.5 and 5 mm were observed at the end of 225 d operation. RTD study showed the flow behavior was in mixed regime at the end of performance study. Step wise polynomial regression analysis was fitted well. Methanobacterium and Methanosaeta bacteria were dominant at the end of start-up whereas Methanosarcina, Cocci and rods were predominant at the end of performance studies.  相似文献   

5.
Lim SJ  Fox P 《Bioresource technology》2011,102(4):3724-3729
A static granular bed reactor (SGBR) was used to treat swine wastewater at 24 and 16 °C. At 24 °C, the organic loading rate (OLR) was 0.7-5.4 kg COD/m3 day and the average chemical oxygen demand (COD) removal efficiency was 88.5%, respectively. Meanwhile, at 16 °C, the OLR was 1.6-4.0 kg COD/m3 day and the average COD removal efficiency was 68.0%, respectively. The SGBR acted as a bioreactor as well as a biofilter. After backwashing, the recovery of COD removal was not a function of an OLR but recovery time, while that of TSS removal was not a function of either recovery time or the OLR. The maximum substrate utilization rate (kmax) ratio was 1.89 between 24 and 16 °C, and the half velocity constant (Ks) ratio was 1.22, and the maximum specific growth rate (μmax) ratio was 4.71. In addition, the temperature-activity coefficient in this study was determined to be 1.09.  相似文献   

6.
Ozonation pretreatment was applied to palm oil mill effluent (POME) prior to anaerobic digestion using the anaerobic sequencing batch reactor (ASBR). Ozonation increased BOD/COD by 37.9% with a COD loss of only 3.3%. At organic loads of 6.48-12.96 kg COD/m3/d, feeding with non-ozonated POME caused a system failure. The ozonated POME gave significantly higher TCOD removal at loadings 6.52 and 9.04 kg COD/m3/d but failed to sustain the operation at loading 11.67 kg COD/m3/d. Effects of cycle time (CT) and hydraulic retention time (HRT) were determined using quadratic regression model. The generated response surface and contour plot showed that at this high load conditions (6.52-11.67 kg COD/m3/d), longer HRT and shorter CT gave the ASBR higher organic removal efficiency and methane yield. The model was able to satisfactorily describe the relationship of these two key operating parameters.  相似文献   

7.
This study focuses on the enhancement of an Austrian anaerobic digestion plant at a slaughterhouse site which exclusively uses animal by-products as substrate. High ammonia concentrations from protein degradation cause severe inhibitions of anaerobic microorganisms. For improving the current situation the COD:TKN ratio is widened by (a) ammonia stripping directly out of the process and (b) addition of a C source to the substrate. Different OLR and HRT were tested in continuous experiments to simulate new operating conditions. The results show that the addition of carbon cannot improve fermentation capacity. The reduction of ammonia boosts the degradation: After reduction of TKN from 7.5 to 4.0 g kg−1 the initially high VFA concentration decreased and the COD degradation was improved by 55.5%. Hence, the implementation of the new N reduction process facilitates either the increase of the OLR by 61% or the reduction of the HRT by 25%.  相似文献   

8.
Lim SJ  Fox P 《Bioresource technology》2011,102(11):6399-6404
In order to evaluate the static granular bed reactor (SGBR), a chemical oxygen demand (COD) balance was used along with a mathematical model. The SGBR was operated with an organic loading rate (OLR) ranging from 0.8 to 5.5 kg/m3 day at 24 °C. The average COD removal efficiency was 87.4%, and the removal efficiencies of COD, carbohydrates, and proteins increased with an OLR, while the lipids removal efficiency was not a function of an OLR. From the results of the COD balance, the yield of biomass increased with an OLR. The SGBR was modeled using the general transport equation considering advection, diffusion, and degradation by microorganisms, and the first-order reaction rate constant was 0.0166/day. The simulation results were in excellent agreement with experimental data. In addition, the SGBR model provided mechanistic insight into why the COD removal efficiency in the SGBR is proportional to an OLR.  相似文献   

9.
Functional role of biomolecules viz., carbohydrates and proteins on acidogenic biohydrogen (H2) production was studied through the treatment of canteen based composite food waste. The performance was evaluated in an anaerobic sequencing batch reactor (AnSBR) at pH 6 with five variable organic loading conditions (OLR1, 0.854; OLR2, 1.69; OLR3, 3.38; OLR4, 6.54 and OLR5, 9.85 kg COD/m3-day). Experimental data depicted the feasibility of H2 production from the stabilization of food waste and was found to depend on the substrate load. Among the five loading conditions studied, OLR4 documented maximum H2 production (69.95 mmol), while higher substrate degradation (3.99 kg COD/m3-day) was observed with OLR5. Specific hydrogen yield (SHY) vary with the removal of different biomolecules and was found to decrease with increase in the OLR. Maximum SHY was observed with hexose removal at OLR1 (139.24 mol/kg HexoseR at 24 h), followed by pentoses (OLR1, 108.26 mol/kg PentoseR at 48 h), proteins (OLR1, 109.71 mol/kg ProteinR at 48 h) and total carbohydrates (OLR1, 58.31 mol/kg CHOR at 24 h). Proteins present in wastewater helped to maintain the buffering capacity but also enhanced the H2 production by supplying readily available organic nitrogen to the consortia. Along with carbohydrates and proteins, total solids also registered good removal.  相似文献   

10.
This study verifies the potential applicability of horizontal-flow anaerobic immobilized biomass (HAIB) reactors to pentachlorophenol (PCP) dechlorination. Two bench-scale HAIB reactors (R1 and R2) were filled with cubic polyurethane foam matrices containing immobilized anaerobic sludge. The reactors were then continuously fed with synthetic wastewater consisting of PCP, glucose, acetic acid, and formic acid as co-substrates for PCP anaerobic degradation. Before being immobilized in polyurethane foam matrices, the biomass was exposed to wastewater containing PCP in reactors fed at a semi-continuous rate of 2.0 μg PCP g−1 VS. The applied PCP loading rate was increased from 0.05 to 2.59 mg PCP l−1 day−1 for R1, and from 0.06 to 4.15 mg PCP l−1 day−1 for R2. The organic loading rates (OLR) were 1.1 and 1.7 kg COD m−3 day−1 at hydraulic retention times (HRT) of 24 h for R1 and 18 h for R2. Under such conditions, chemical oxygen demand (COD) removal efficiencies of up to 98% were achieved in the HAIB reactors. Both reactors exhibited the ability to remove 97% of the loaded PCP. Dichlorophenol (DCP) was the primary chlorophenol detected in the effluent. The adsorption of PCP and metabolites formed during PCP degradation in the packed bed was negligible for PCP removal efficiency.  相似文献   

11.
In the present study possibility of coupling stripper to remove ammonia to the UASB reactor treating poultry litter leachate was studied to enhance the overall performance of the reactor. UASB reactor with stripper as ammonia inhibition control mechanism exhibited better performance in terms of COD reduction (96%), methane yield (0.26m(3)CH(4)/kg COD reduced), organic loading rate (OLR) (18.5kg COD m(-3)day(-1)) and Hydraulic residence time (HRT) (12h) compared to the UASB reactor without stripper (COD reduction: 92%; methane yield: 0.21m(3)CH(4)/kg COD reduced; OLR: 13.6kg CODm(-3)day(-1); HRT: 16h). The improved performance was due to the reduction of total ammonia nitrogen (TAN) and free ammonia nitrogen (FAN) in the range of 75-95% and 80-95%, respectively by the use of stripper. G/L (air flow rate/poultry leachate flow rate) in the range of 60-70 and HRT in the range of 7-9min are found to be optimum parameters for the operation of the stripper.  相似文献   

12.
Investigation on a full-scale UASB treating industrial wastewater at a low organic loading rate (OLR) was conducted. Excellent treatment performance was achieved when treating the evaporator condensate of distillery wastewater at the OLR of less than 1 kg COD/m3 d. Anaerobic effluent could be discharged without further treatment, which saved energy and running cost considerably. GC–MS analysis showed that the soluble microbial products (SMPs) were decreased to a low level at the low OLR. The main SMP in the anaerobic effluent were long chain carbohydrates and esters, accounting for 55–65% of the total organic matters. Anaerobic SMP was more complex than the aerobic ones.  相似文献   

13.
Wu B  Yi S  Fane AG 《Bioresource technology》2011,102(13):6808-6814
Microbial community developments and biomass characteristics (concentration, particle size, extracellular polymeric substances (EPS), and membrane fouling propensity) were compared when three MBRs were fed with the synthetic wastewater at different organic loadings. Results showed that the bacterial communities dynamically shifted in different ways and the EPS displayed dissimilar profiles under various organic loadings, which were associated with the ratios of food to microorganism and dissolved oxygen levels in the MBRs. The membrane fouling tendency of biomass in the low-loading MBR (0.57 g COD/L day) was insignificantly different from that in the medium-loading MBR (1.14 g COD/L day), which was apparently lower than that in the high-loading MBR (2.28 g COD/L day). The membrane fouling propensity of biomass was strongly correlated with their bound EPS contents, indicating cake layer fouling (i.e., deposition of microbial flocs) was predominant in membrane fouling at a high flux of 30 L/m2 h.  相似文献   

14.
The influence of the hydraulic retention time (HRT) and organic loading rate (OLR) on the performance of the hydrolytic–acidogenic step of a two-stage anaerobic digestion process of sunflower oil cake (SuOC) were assessed. The experiments were performed in laboratory-scale completely stirred tank reactors at mesophilic (35 °C) temperature. Six OLR (ranging from 4 to 9 g VS L−1 d−1) for four HRTs (8, 10, 12 and 15 days) were tested to check the effect of each operational variable. Based on the results obtained, it can be concluded that the hydrolysis yields obtained for all HRTs and OLRs assayed were in the range of 20.5–30.1%. In addition, the acidification degree of the substrate was mainly influenced by the OLR but not by the HRTs, the highest value (83.8%) being achieved for an HRT of 10 days and an OLR of 6 g VS L−1 d−1.  相似文献   

15.
16.
Ye J  Mu Y  Cheng X  Sun D 《Bioresource technology》2011,102(9):5498-5503
Treatment of a fresh leachate with high-strength organics and calcium from municipal solid waste (MSW) incineration plant by an up-flow anaerobic sludge blanket (UASB) reactor was investigated under mesophilic conditions, emphasizing the influence of organic loading rate (OLR). When the reactor was fed with the raw leachate (COD as high as 70,390-75,480 mg/L) at an OLR of 12.5 kg COD/(m3 d), up to ∼82.4% of COD was removed suggesting the feasibility of UASB process for treating fresh leachates from incineration plants. The ratio of volatile solids/total solids (VS/TS) of the anaerobic sludge in the UASB decreased significantly after a long-term operation due to the precipitation of calcium carbonate in the granules. Scanning electron microscopy (SEM) observation shows that Methanosaeta-like species were in abundance, accompanied by a variety of other species. The result was further confirmed by polymerase chain reaction-denaturing gradient gel electrophoresis (PCR-DGGE) and sequencing.  相似文献   

17.
Zhang J  Wei Y  Xiao W  Zhou Z  Yan X 《Bioresource technology》2011,102(16):7407-7414
An anaerobic baffled reactor with four compartments (C1-C4) was successfully used for treatment of acetone-butanol-ethanol fermentation wastewater and methane production. The chemical oxygen demand (COD) removal efficiency was 88.2% with a CH4 yield of 0.25 L/(g CODremoved) when organic loading rate (OLR) was 5.4 kg COD m−3 d−1. C1 played the most important role in solvents (acetone, butanol and ethanol) and COD removal. Community structure of C2 was similar to that in C1 at stage 3 with higher OLR, but was similar to those in C3 and C4 at stages 1-2 with lower OLR. This community variation in C2 was consistent with its increased role in COD and solvent removal at stage 3. During community succession from C1 to C4 at stage 3, abundance of Firmicutes (especially OTUs ABRB07 and ABRB10) and Methanoculleus decreased, while Bacteroidetes and Methanocorpusculum became dominant. Thus, ABRB07 coupled with Methanoculleus and/or acetogen (ABRB10) may be key species for solvents degradation.  相似文献   

18.
The performance of a laboratory-scale sewage treatment system composed of an up-flow anaerobic sludge blanket (UASB) reactor and a moving bed biofilm reactor (MBBR) at a temperature of (22–35 °C) was evaluated. The entire treatment system was operated at different hydraulic retention times (HRT’s) of 13.3, 10 and 5.0 h. An overall reduction of 80–86% for CODtotal; 51–73% for CODcolloidal and 20–55% for CODsoluble was found at a total HRT of 5–10 h, respectively. By prolonging the HRT to 13.3 h, the removal efficiencies of CODtotal, CODcolloidal and CODsoluble increased up to 92, 89 and 80%, respectively. However, the removal efficiency of CODsuspended in the combined system remained unaffected when increasing the total HRT from 5 to 10 h and from 10 to 13.3 h. This indicates that, the removal of CODsuspended was independent on the imposed HRT. Ammonia-nitrogen removal in MBBR treating UASB reactor effluent was significantly influenced by organic loading rate (OLR). 62% of ammonia was eliminated at OLR of 4.6 g COD m−2 day−1. The removal efficiency was decreased by a value of 34 and 43% at a higher OLR’s of 7.4 and 17.8 g COD m−2 day−1, respectively. The mean overall residual counts of faecal coliform in the final effluent were 8.9 × 104 MPN per 100 ml at a HRT of 13.3 h, 4.9 × 105 MPN per 100 ml at a HRT of 10 h and 9.4 × 105 MPN per 100 ml at a HRT of 5.0 h, corresponding to overall log10 reduction of 2.3, 1.4 and 0.7, respectively. The discharged sludge from UASB–MBBR exerts an excellent settling property. Moreover, the mean value of the net sludge yield was only 6% in UASB reactor and 7% in the MBBR of the total influent COD at a total HRT of 13.3 h. Accordingly, the use of the combined UASB–MBBR system for sewage treatment is recommended at a total HRT of 13.3 h.  相似文献   

19.
Summary Start-up and operation of a fluidized-bed reactor were investigated with butyrate or butyrate plus acetate as sole substrates. Start-up could be enhanced by increasing the amount of inoculum and by providing balanced substrate concentrations in a wellbuffered synthetic wastewater. High-rate degradation of butyrate to methane and carbon dioxide was achieved with a maximum organic loading rate (OLR) of 34.5 kg chemical oxygen demand (COD)/m3·d at a hydraulic retention time (HRT) of 0.47 d and with a COD removal efficiency of 87%.  相似文献   

20.
This paper describes the thermophilic (55 °C) anaerobic biodegradation of a mixed feed composed of vinasses and cutting oil wastewater (COW) in a laboratory upflow anaerobic fixed-film reactor (UAFF) with a porous support medium. The experimental protocol was defined to examine the effect of increasing the percentage of cutting oil wastewater in the feed.The UAFF reactor was initially started-up with vinasses as the only carbon source at an organic loading rate of 22.3 kg COD/m3 day and HRT of 0.8 days using porous particles as the support (SIRAN). The percentage of organic matter composed of vinasses was subsequently reduced while increasing the amount of cutting oil until 100% of cutting oil wastewater was added in the feed. Four stages were considered in the study (0, 42.4, 66.6 and 100% COW). HRT was adjusted in order to maintain an approximately constant organic loading rate applied to the system. Under theses conditions, the UAFF reactor was subjected to a programme of steady-state operation with hydraulic retention times (HRT) in the range 0.8–0.15 days and organic loading rates (OLR) between 22.3 and 14.9 kg COD/m3 day in order to evaluate the treatment capacity of the system.The COD removal efficiency was found to be 87% COD and 94.6% TOC in the reactor when treating vinasses at 22.3 kg COD/m3 day. The volumetric methane level produced in the digester reached 0.45 m3/m3 day. After an operating period of 120 days, the reactor was fed with cutting oil wastewater (COW) as the only source of carbon. An OLR of 16.7 kg COD/m3 day was achieved with 85.8% COD removal efficiency (58.1%TOC) in the experimental UAFF reactor. Under these conditions the volumetric methane produced in the digester was negligible.Hence, COW can be removed, if not degraded, by anaerobic treatment in the presence of a biodegradable co-substrate. Wine vinasses degradation creates conditions for non-biological removal of COW constituents. More studies are necessary in order to test the mechanisms of organic removal when biodegradation apparently had ceased. Also, toxicity assays of COW are necessary to evaluate the toxicity to the methanogenic community.  相似文献   