首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到17条相似文献,搜索用时 93 毫秒
1.
针对大肠杆菌O157:H7(Escherichia coli O157:H7,E.coli O157:H7)传统检测方法检测周期长的问题,建立了肉类中的E.coli O157:H7的改良环介导等温扩增(LAMP)快速检测方法。以E.coli O157:H7的O157特异性抗原rfbE基因、鞭毛H7特异性抗原fliC基因序列作为靶序列,分别设计2套增加了环引物的改良LAMP引物序列,单管同时检测,通过肉眼观察白色沉淀,判断检测结果。采用36株细菌验证了该改良LAMP引物的特异性。热裂解法提取的DNA经改良LAMP体系扩增20 min,检测E.coli O157:H7的灵敏度为1.4 CFU/mL,人工污染肉中的E.coli O157:H7检出限为1.8 CFU/g。137份实样中,检测出1份E.coli O157:H7假阳性,与行业标准SNT0973-2000符合率达到99.3%。  相似文献   

2.
【背景】大肠杆菌(Escherichia coli) O157:H7是导致肠出血性大肠杆菌食源性疾病暴发的主要血清型,免疫磁珠(Immunomagnetic beads,IMBS)在E. coli O157的检测中发挥着重要作用,而免疫磁珠的稳定性、特异性、广谱性等性能指标关系着在实际应用中的使用效果。【目的】制备高效、稳定且具有广谱性的免疫磁珠,联合分子检测技术如环介导恒温扩增 (Loop-mediated isothermal amplification,LAMP)技术、PCR等,提高目标菌的检出率。【方法】采用新型的磁珠活化剂MIX&GO制备E. coli O157免疫磁珠,并进行广谱性以及特异性检测;针对6种试剂牛血清白蛋白(Bovine serum albumin,BSA)、酪蛋白(Casein)、海藻糖(Trehalose)、聚乙烯吡咯烷酮(Polyvinyl pyrrolidone,PVP)、抗坏血酸(Vitamin C)和防腐剂ProClin 300,利用正交试验L18(37)优化免疫磁珠保存液组分;采用IMBS-LAMP、IMBS-PCR、IMBS-生化、菌液-LAMP、菌液-PCR、显色平板-生化鉴定6种方式对20份生猪肉样品进行检测。【结果】利用MIX&GO活化剂制备的免疫磁珠捕获率最高达到81.5%±1.3%;免疫磁珠保存液最优配方为:牛血清白蛋白15.0 g/L,酪蛋白10.0 g/L,海藻糖10.0 g/L,PVP 2.0 g/L,抗坏血酸5.0 g/L,ProClin 300 2.5 g/L,保存6个月后免疫磁珠捕获率为75.5%;在20份生猪肉样品的检测中,自制磁珠和商品化磁珠与LAMP联用均检出9例阳性样品;IMBS-LAMP在6种检测方式中具有最高的检测灵敏度,但检出的样品会因磁珠抗体的差异而有所不同。【结论】与商品化磁珠相比,实验制备的免疫磁珠具有良好的特异性和广谱性,免疫磁珠-LAMP联用提高了目标菌的检出率,是一种高灵敏度、具有应用前景的检测方法。  相似文献   

3.
以编码大肠杆菌O157抗原的rfbE基因、 编码H7抗原的fliC基因以及编码毒力因子的eaeA基因为靶基因, 选择3对引物, 建立并优化了检测大肠杆菌O157:H7的多重PCR体系, 扩增产物分别为291 bp、625 bp、368 bp, 采用30株细菌验证了该多重PCR具有特异性。PCR检测的灵敏度在DNA水平上达到91.35 pg; 在存在干扰菌鼠伤寒沙门氏菌(Salmonella?typhimurium)的情况下, 当起始污染量为1.4 CFU/mL时, 37 ℃培养6 h 即可检出。在30份肉类样品中, 有3份检出了大肠杆菌O157:H7。本研究建立的多重PCR方法可特异、灵敏地实现对大肠杆菌O157:H7的检测。  相似文献   

4.
大肠杆菌O157:H7核酸探针检测方法的建立   总被引:1,自引:0,他引:1  
目的:应用核酸探针方法快速检测大肠杆菌O157:H7。方法:通过使用吖啶酯标记的特异DNA探针方法检测大肠杆菌O157:H7,对此种方法的特异性、敏感性、准确性进行研究,比较该方法与传统国标法的检测结果。结果:核酸探针方法检测大肠杆菌O157:H7特异性以及敏感性强,检出大肠杆菌O157:H7菌液浓度最低限约为106cfu/ml,检测大肠杆菌O157:H7的结果与国标法相一致;对O157:H7鉴定时间仅需30min,简便快捷。结论:核酸探针方法可用于大肠杆菌O157:H7的快速检测。  相似文献   

5.
大肠杆菌O157:H7是肠出血型大肠杆菌(EHEC)的主要病原血清型,它可产生特殊的粘附因子粘附靶细胞,产生Vero毒素和肠溶血素毒力因子.近几年对大肠杆菌O157:H7的毒力因子有了深入的了解,对致病机理作了一些探讨,用实验动物对保护性免疫进行了研究.本文对近几年来0157:H7大肠杆菌的致病因子及其主要的保护性免疫的研究作一简要综述.  相似文献   

6.
【目的】建立一种同时快速检测大肠杆菌O157:H7(E.coli O157:H7)和鼠伤寒沙门氏菌(Salmonella typhimurium)的可视化抗体阵列技术。【方法】将免疫学技术与蛋白芯片技术相结合,基于双抗体夹心法检测原理利用蛋白质芯片技术的高通量,结合可视化结果判定技术,用一份样品,同步检测大肠杆菌O157:H7和鼠伤寒沙门氏菌两种病原。【结果】检测结果肉眼可见,检测周期短至90 min,纯菌液检测灵敏度达105 CFU/mL,模拟带菌检测灵敏度为106 CFU/mL,与常规的ELISA灵敏度等同且具有良好的特异性和重复性。【结论】该可视化抗体阵列检测结果肉眼可见,检测通量高,无需大型设备,操作简便,检测成本低廉,同时为快速检测致病菌提供一种新途径。  相似文献   

7.
DNA环介导恒温扩增技术快速检测霍乱弧菌   总被引:1,自引:0,他引:1  
霍乱弧菌是一种重要的食源性致病菌,主要引起急性肠道传染病,其快速检测具有重要意义。根据霍乱弧菌的mdh管家基因序列,设计2对特异性检测引物,利用DNA环介导恒温扩增技术(Loop-mediated isothermal amplification,LAMP),经反应体系优化,成功建立了霍乱弧菌的LAMP快速检测方法。该方法最佳反应温度为65℃,60min完成检测,对培养菌的检测限为25CFU/mL,污染食品中霍乱弧菌的检测限为32CFU/g。对33株同种或近源细菌进行LAMP检测,仅霍乱弧菌得到阳性扩增。LAMP方法实践应用结果表明,对1057份虾、蟹、牡蛎、肉类、人腹泻物等样本进行检测,共检出85份阳性,与国际标准(ISO TS21872-1-2007)检测结果的符合率为100%。结果表明,本研究建立的霍乱弧菌LAMP检测方法特异性强、灵敏度高、操作简便,有利于霍乱弧菌疫情的监测。  相似文献   

8.
大肠杆菌O157∶H7感染流行概况   总被引:1,自引:0,他引:1  
大肠杆菌O157∶H7是肠出血性大肠杆菌的主要病原血清型,可引起腹泻、出血性肠炎,极易继发溶血性尿毒综合症和血栓性血小板减少性紫癜两种严重的并发症,死亡率高。1982年被发现以来,大肠杆菌O157∶H7已在世界多个国家引起过爆发流行,呈现了流行的世界性,中国也于上世纪90年代末在局部地区出现了爆发,死亡率极高,引起了相关部门的高度重视。本综述试图通过对大肠杆菌O157∶H7在世界范围流行状况的描述,提高公众对该病的认识,为相关疫苗的研发提供流行病学资料。  相似文献   

9.
利用环介导恒温扩增(LAMP)技术,以微囊藻毒素(Microcystins,MCs)合成基因簇中的mcyG基因为靶序列,设计了1 套LAMP引物,建立了LAMP反应体系并进行灵敏度和特异性实验。结果表明mcyG基因的最低检测限为:24 cfu/mL,远低于常规PCR(Polymerase Chain Reaction)。整个检测过程仅需40 min,且可直接目测结果。特异性实验中, 13 株淡水常见水华蓝藻分属:色球藻属(Chroococcus)、念珠藻属(Nostoc)、鱼腥藻属(Anabaena)、束丝藻属(Aphanizomenon)、微囊藻属(Microcystis),其中10 株呈阳性反应, 3 株为阴性。在野外样品检测中,来自太湖与黄庆苗池塘的水样PCR检测显示阴性反应,而LAMP检测均呈阳性反应,提示此两处水样中可能含有产毒微囊藻,显示出了LAMP检测方法良好的野外检测和预警能力。综合上述,LAMP检测方法能够快速检测产微囊藻毒素的关键基因,且结果可视化。该方法简便、快捷、不依赖特殊检测设备,极具推广前景。  相似文献   

10.
利用改良逆转录环介导等温扩增(RT-LAMP)技术建立一种快速、灵敏的检测方法用于H9亚型禽流感病毒检测。根据H9亚型禽流感病毒血凝素(HA)基因保守区序列中的8个区段设计6条特异性引物,在恒温条件下进行核酸扩增反应,并以琼脂糖凝胶电泳和目视检查绿色荧光两种方法对扩增结果进行判定。结果表明,RT-LAMP的最小检测限为100 fg,灵敏度比PT-PCR高100倍,且与H5亚型、H7亚型禽流感病毒,新城疫病毒(NDV)无交叉反应。目视检查绿色荧光与常规琼脂糖凝胶电泳的判定结果一致。整个扩增检测过程在35 min内即可完成。利用临床样本对RT-LAMP法进行验证,结果与RT-PCR一致。由实时浊度分析得到的标准曲线,计算出临床样本中的病毒质粒拷贝数均在2×107-2×104之间。因此,本研究建立的RT-LAMP方法快速、灵敏、特异性强,是H9亚型禽流感病毒的一种高效检测方法。  相似文献   

11.
Direct PCR detection of Escherichia coli O157:H7   总被引:2,自引:0,他引:2  
AIMS: This paper reports a simple, rapid approach for the detection of Shiga toxin (Stx)-producing Escherichia coli (STEC). METHODS AND RESULTS: Direct PCR (DPCR) obviates the need for the recovery of cells from the sample or DNA extraction prior to PCR. Primers specific for Stx-encoding genes stx1 and stx2 were used in DPCR for the detection of E. coli O157:H7 added to environmental water samples and milk. CONCLUSIONS: PCR reactions containing one cell yielded a DPCR product. SIGNIFICANCE AND IMPACT OF THE STUDY: This should provide an improved method to assess contamination of environmental and other samples by STEC and other pathogens.  相似文献   

12.
Escherichia coli O157:H7 is an important pathogenic Bacterium that threatens human health. A convenient, sensitive and specific method for the E. coli O157:H7 detection is necessary. We developed two pairs of monoclonal antibodies through traditional hybridoma technology, one specifically against E. coli O157 antigen and the other specifically against E. coli H7 antigen. Using these two pairs of antibodies, we developed two rapid test kits to specifically detect E. coli O157 antigen and E. coli H7 antigen, respectively. The detection sensitivity for O157 positive E. coli is 1 × 103 CFU per ml and for H7 positive E. coli is 1 × 104 CFU per ml. Combining these two pairs of antibodies together, we developed a combo test strip that can specifically detect O157: H7, with a detection sensitivity of 1 × 104 CFU per ml, when two detection lines are visible to the naked eye. This is currently the only rapid detection reagent that specifically detects O157: H7 by simultaneously detecting O157 antigen and H7 antigens of E. coli. Our product has advantages of simplicity and precision, and can be a very useful on-site inspection tool for accurate and rapid detection of E. coli O157:H7 infection.  相似文献   

13.
AIMS: Combinations of PCR primer sets were evaluated to establish a multiplex PCR method to specifically detect Escherichia coli O157:H7 genes in bovine faecal samples. METHODS AND RESULTS: A multiplex PCR method combining three primer sets for the E. coli O157:H7 genes rfbE, uidA and E. coli H7 fliC was developed and tested for sensitivity and specificity with pure cultures of 27 E. coli serotype O157 strains, 88 non-O157 E. coli strains, predominantly bovine in origin and five bacterial strains other than E. coli. The PCR method was very specific in the detection of E. coli O157:H7 and O157:H- strains, and the detection limit in seeded bovine faecal samples was <10 CFU g(-1) faeces, following an 18-h enrichment at 37 degrees C, and could be performed using crude DNA extracts as template. CONCLUSIONS: A new multiplex PCR method was developed to detect E. coli O157:H7 and O157:H-, and was shown to be highly specific and sensitive for these strains both in pure culture and in crude DNA extracts prepared from inoculated bovine faecal samples. SIGNIFICANCE AND IMPACT OF THE STUDY: This new multiplex PCR method is suitable for the rapid detection of E. coli O157:H7 and O157:H- genes in ruminant faecal samples.  相似文献   

14.
A total of 401 enterohemorrhagic Escherichia coli (EHEC) O157:H7 isolates from two experimentally infected calves were analyzed using molecular biological methods. Genetic differences detected by pulsed-field gel electrophoresis were observed between the inoculated and recovered strains as early as 1 day post inoculation. The loss of the inoculated clone was observed in one calf. Replication and dissemination of the EHEC O157:H7 strains that mutated in cattle may result in the diversification of this organism among cattle populations.  相似文献   

15.
摘要:【目的】结合纳米技术建立检测大肠杆菌(Escherichia coli)O157︰H7高灵敏检测技术。【方法】采用化学共沉淀法制备出核心粒径约为10 nm的免疫纳米磁颗粒,柠檬酸钠还原法制备粒径约为20 nm的免疫胶体金。压电免疫传感器通过金黄色葡萄球菌蛋白A(Protein A from Staphylococcus aureus SPA)法将抗体固定于石英晶振上,两种免疫纳米颗粒借助不同的抗体连接于传感器上对检测频率信号进行放大。【结果】SPA在石英晶振上的最佳固定浓度和时间为1.2 mg/mL和40 min,抗体的最佳固定浓度和时间为1.0 mg/mL和60 min。压电免疫传感器通过两种免疫纳米颗粒的放大作用,使其对大肠杆菌O157︰H7的检测限从104 cfu/mL提高到101 cfu/mL。【结论】免疫纳米颗粒强化对压电免疫传感器的检测频率信号具有很好的放大效应,可以明显提高其检测灵敏度。  相似文献   

16.
Enterohaemorrhagic Escherichia coli O157:H7 was first implicated in human disease in the early 1980s, with ruminants cited as the primary reservoirs. Preliminary studies indicated cattle to be the sole source of E. coli O157:H7 outbreaks in humans; however, further epidemiological studies soon demonstrated that E. coli O157:H7 was widespread in other food sources and that a number of transmission routes existed. More recently, small domestic ruminants (sheep and goats) have emerged as important sources of E. coli O157:H7 human infection, particularly with the widespread popularity of petting farms and the increased use of sheep and goat food products, including unpasteurized cheeses. Although the colonization and persistence characteristics of E. coli O157:H7 in the bovine host have been studied intensively, this is not the case for small ruminants. Despite many similarities to the bovine host, the pathobiology of E. coli O157:H7 in small domestic ruminants does appear to differ significantly from that described in cattle. This review aims to critically review the current knowledge regarding colonization and persistence of E. coli O157:H7 in small domestic ruminants, including comparisons with the bovine host where appropriate.  相似文献   

17.
AIMS: Developing and evaluating a rapid real-time polymerase chain reaction (PCR) method for the identification of Escherichia coli O157:H7 in cattle and dairy wastewater samples produced from mozzarella cheese factories, without pre-enrichment step before DNA extraction. METHODS AND RESULTS: Wastewater samples were collected from a dairy farm producing mozzarella cheese and located in Puglia (south of Italy). Plate count and other microbial assays were performed 1 h after sampling. Wastewater samples were artificially inoculated with 10(4), 10(7) and 10(8) cells ml(-1) of E. coli O157:H7, strain EDL933. PCR protocols for stx1, stx2 and eae genes were first tested on pure DNA extracted from type strains, in order to optimize the amplification conditions and reagent concentration before real-time PCR experiments. Three specific fragments of ca 106, 150 and 200 bp corresponding to genes eae, stx1 and stx2, respectively, were obtained. Real-time PCR experiments were performed with DNA extracted from dairy and manure wastewater samples inoculated with 10(4), 10(7) and 10(8) colony-forming units (CFU) ml(-1) of E. coli O157:H7 strain EDL 933. The sensitivity limit of the assay was 10(-1) pg microl(-1) for eae, stx2 and 16SrRNA, and 1 pg microl(-1) for stx1 gene respectively. CONCLUSIONS: A real-time PCR protocol has been developed and used in order to identify potential pathogens in dairy wastewater, in which previous methods (including standard PCR) failed to work. SIGNIFICANCE AND IMPACT OF THE STUDY: Cattle and dairy wastewater samples produced from mozzarella cheese factories may harbour verocytotoxin-producing E. coli. The availability of rapid and sensitive molecular methods may be useful to monitor the persistence of verocytotoxin-producing E. coli in general and to assess the effectiveness of wastewater treatments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号