首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Bioprinting has a great potential to fabricate three‐dimensional (3D) functional tissues and organs. In particular, the technique enables fabrication of 3D constructs containing stem cells while maintaining cell proliferation and differentiation abilities, which is believed to be promising in the fields of tissue engineering and regenerative medicine. We aimed to demonstrate the utility of the bioprinting technique to create hydrogel constructs consisting of hyaluronic acid (HA) and gelatin derivatives through irradiation by visible light to fabricate 3D constructs containing human adipose stem cells (hADSCs). The hydrogel was obtained from a solution of HA and gelatin derivatives possessing phenolic hydroxyl moieties in the presence of ruthenium(II) tris‐bipyridyl dication and sodium ammonium persulfate. hADSCs enclosed in the bioprinted hydrogel construct elongated and proliferated in the hydrogel. In addition, their differentiation potential was confirmed by examining the expression of pluripotency marker genes and cell surface marker proteins, and differentiation to adipocytes in adipogenic differentiation medium. Our results demonstrate the great potential of the bioprinting method and the resultant hADSC‐laden HA/gelatin constructs for applications in tissue engineering and regenerative medicine.  相似文献   

2.
One of the challenges in tissue engineering is to provide adequate supplies of oxygen and nutrients to cells within the engineered tissue construct. Soft‐lithographic techniques have allowed the generation of hydrogel scaffolds containing a network of fluidic channels, but at the cost of complicated and often time‐consuming manufacturing steps. We report a three‐dimensional (3D) direct printing technique to construct hydrogel scaffolds containing fluidic channels. Cells can also be printed on to and embedded in the scaffold with this technique. Collagen hydrogel precursor was printed and subsequently crosslinked via nebulized sodium bicarbonate solution. A heated gelatin solution, which served as a sacrificial element for the fluidic channels, was printed between the collagen layers. The process was repeated layer‐by‐layer to form a 3D hydrogel block. The printed hydrogel block was heated to 37°C, which allowed the gelatin to be selectively liquefied and drained, generating a hollow channel within the collagen scaffold. The dermal fibroblasts grown in a scaffold containing fluidic channels showed significantly elevated cell viability compared to the ones without any channels. The on‐demand capability to print fluidic channel structures and cells in a 3D hydrogel scaffold offers flexibility in generating perfusable 3D artificial tissue composites. Biotechnol. Bioeng. 2010;105: 1178–1186. © 2009 Wiley Periodicals, Inc.  相似文献   

3.
Wide‐field optical coherence tomography angiography (OCTA) is gaining interest in clinical imaging applications. In this pursuit, it is challenging to maintain the imaging resolution and sensitivity throughout the wide field of view (FoV). Here, we propose a novel method/system of dual‐beam arrangement and Fourier‐domain multiplexing to achieve wide‐field OCTA when imaging the uneven surface samples. The proposed system provides 2 separate FoVs, with flexibility that the imaging area, focus of the imaging beam and imaging depth range can be individually adjusted for each FoV, leading to either (1) increased system imaging FoV or (2) capability of targeting 2 regions of interests that locate at depths with large difference between each other. We demonstrate this novel method by employing 100 kHz laser source in a swept source OCTA to achieve an effective 200 kHz sweeping rate, covering a 22 × 22 mm FoV. The results are verified by a SS‐OCTA system employing a 200 kHz laser source, together with the experimental demonstrations when imaging whole brain vasculature in rodent models and skin blood perfusion in human fingers, show‐casing the capability of proposed system to image live large samples with complex surface topography.   相似文献   

4.
Optical fibers have recently attracted a noticeable interest for biomedical applications because they provide a minimally invasive method for in vivo sensing, imaging techniques, deep‐tissue photodynamic therapy or optogenetics. The silica optical fibers are the most commonly used because they offer excellent optical properties, and they are readily available at a reasonable price. The fused silica is a biocompatible material, but it is not bioresorbable so it does not decompose in the body and the fibers must be ex‐planted after in vivo use and their fragments can present a considerable risk to the patient when the fiber breaks. In contrast, optical fibers made of phosphate glasses can bring many benefits because such glasses exhibit good transparency in ultraviolet‐visible and near‐infrared regions, and their solubility in water can be tailored by changing the chemical composition. The bioresorbability and toxicity of phosphate glass–based optical fibers were tested in vivo on male laboratory rats for the first time. The fiber was spliced together with a standard graded‐index multi‐mode fiber pigtail and an optical probe for in vitro pH measurement was prepared by the immobilization of a fluorescent dye on the fiber tip by a sol‐gel method to demonstrate applicability and compatibility of the fiber with common fiber optics.   相似文献   

5.
We show that polarization‐sensitive optical coherence tomography angiography (PS‐OCTA) based on full Jones matrix assessment of speckle decorrelation offers improved contrast and depth of vessel imaging over conventional OCTA. We determine how best to combine the individual Jones matrix elements and compare the resulting image quality to that of a conventional OCT scanner by co‐locating and imaging the same skin locations with closely matched scanning setups. Vessel projection images from finger and forearm skin demonstrate the benefits of Jones matrix‐based PS‐OCTA. Our study provides a promising starting point and a useful reference for future pre‐clinical and clinical applications of Jones matrix‐based PS‐OCTA.  相似文献   

6.
The three‐dimensional (3D) mechanical properties characterization of tissue is essential for physiological and pathological studies, as biological tissue is mostly heterogeneous and anisotropic. A digital volume correlation (DVC)‐based 3D optical coherence elastography (OCE) method is developed to measure the 3D displacement and strain tensors. The DVC algorithm includes a zero‐mean normalized cross‐correlation criterion‐based coarse search regime, an inverse compositional Gauss‐Newton fine search algorithm and a local ternary quadratic polynomial fitting strain calculation method. A 3D optical coherence tomography (OCT) scanning protocol is proposed through theoretical analysis and experimental verification. Measurement errors of the DVC‐based 3D OCE method are evaluated to be less than 2.0 μm for displacements and 0.30% for strains by rigid body motion experiments. The 3D displacements and strains of a phantom and a specimen of chicken breast tissue under compression are measured. Results of the phantom show a good agreement with theoretical analysis and tensile testing. The strains of the chicken breast tissue indicate anisotropic biomechanical properties. This study provides an effective method for 3D biomechanical property studies of soft tissue and improves the development of 3D OCE techniques.  相似文献   

7.
Uncovering the key contributions of molecular details to capture polysulfides is important for applying suitable materials that can effectively restrain the shuttle effect in advanced lithium–sulfur batteries. This is particularly true for natural biomolecules with substantial structural and compositional diversities strongly impacting their functions. Here, natural gelatin and zein proteins are first denatured and then adopted for fabrication of nanocomposite interlayers via functionalization of carbon nanofibers. From the results of experiment and molecular dynamic simulations, it is found that the lengths of the sidechains on the two proteins play critical roles. The short‐branched gelatin shows significantly stronger adsorption of polysulfides, as compared with zein comprising many long‐chain residues. The gelatin‐based interlayer, along with its good porous structures/electrical conductivity, greatly suppresses the shuttle effect and yields exceptional electrochemical performance. Furthermore, the implementation of proteins as functional binder additives further supports the finding that gelatin enables stronger polysulfide‐trapping. As a result, high‐loading sulfur cathodes (9.4 mg cm?2) are realized, which deliver a high average areal capacity of 8.2 mAh cm?2 over 100 cycles at 0.1 A g?1. This work demonstrates the importance of sidechain length in capturing polysulfides and provides a new insight in selecting and design of desired polysulfide‐binding molecules.  相似文献   

8.
Optical coherence Doppler tomography (ODT) increasingly attracts attention because of its unprecedented advantages with respect to high contrast, capillary‐level resolution and flow speed quantification. However, the trade‐off between the signal‐to‐noise ratio of ODT images and A‐scan sampling density significantly slows down the imaging speed, constraining its clinical applications. To accelerate ODT imaging, a deep‐learning‐based approach is proposed to suppress the overwhelming phase noise from low‐sampling density. To handle the issue of limited paired training datasets, a generative adversarial network is performed to implicitly learn the distribution underlying Doppler phase noise and to generate the synthetic data. Then a 3D based convolutional neural network is trained and applied for the image denoising. We demonstrate this approach outperforms traditional denoise methods in noise reduction and image details preservation, enabling high speed ODT imaging with low A‐scan sampling density.  相似文献   

9.
Measuring blood flow speed in the optical diffusive regime in humans has been a long standing challenge for photoacoustic tomography. In this work, we proposed a cuffing‐based method to quantify blood flow speed in humans with a handheld photoacoustic probe. By cuffing and releasing the blood vessel, we can measure the blood flow speed downstream. In phantom experiments, we demonstrated that the minimum and maximum measurable flow speeds were 0.035 mm/s and 42 mm/s, respectively. In human experiments, flow speeds were measured in three different blood vessels: a radial artery in the right forearm, a radial artery in the index finger of the right hand, and a radial vein in the right forearm. Taking advantage of the handheld probe, our method can potentially be used to monitor blood flow speed in the clinic and at the bedside.

  相似文献   


10.
A plastic optical fibre biosensor based on surface plasmon resonance for the detection of C‐reactive protein (CRP) in serum is proposed. The biosensor was integrated into a home‐made thermo‐stabilized microfluidic system that allows avoiding any thermal and/or mechanical fluctuation and maintaining the best stable conditions during the measurements. A working range of 0.006–70 mg L–1 and a limit of detection of 0.009 mg L–1 were achieved. These results are among the best compared to other SPR‐based biosensors for CRP detection, especially considering that they were achieved in a real and complex medium, i.e. serum. In addition, since the sensor performances satisfy those requested in physiologically‐relevant clinical applications, the whole biosensing platform could well address high sensitive, easy to realize, real‐time, label‐free, portable and low cost diagnosis of CRP for future lab‐on‐a‐chip applications.

3D sketch (left) of the thermo‐stabilized home‐made flow cell developed to house the SPR‐based plastic optical fibre biosensor. Exemplary response curve (shift of the SPR wavelength versus time) of the proposed biosensor (right) for the detection of C‐reactive protein in serum.  相似文献   


11.
The occurrence and development of ischemic stroke are closely related to cerebral blood flow. Real‐time monitoring of cerebral perfusion level is very useful for understanding the mechanisms of the disease. A wide field of view (FOV) is conducive to capturing lesions and observing the progression of the disease. In this paper, we attempt to monitor the whole‐brain microcirculation in middle cerebral artery occlusion (MCAO) rats over time using a wide FOV swept‐source OCT (SS‐OCT) system. A constrained image registration algorithm is used to remove motion artifacts that are prone to occur in a wide FOV angiography. During ischemia, cerebral perfusion levels in the left and right hemispheres, as well as in the whole brain were quantified and compared. Changes in the shape and location of blood vessels were also recorded. The results showed that the trend in cerebral perfusion levels of both hemispheres was highly consistent during MCAO, and the position of the blood vessels varied over time. This work will provide new insights of ischemic stroke and is helpful to assess the effectiveness of potential treatment strategies.   相似文献   

12.
We present the proof of concept of a general model that uses the tissue sample transmittance as input to estimate the depth‐resolved attenuation coefficient of tissue samples using optical coherence tomography (OCT). This method allows us to obtain an image of tissue optical properties instead of intensity contrast, guiding diagnosis and tissues differentiation, extending its application from thick to thin samples. The performance of our method was simulated and tested with the assistance of a home built single‐layered and multilayered phantoms (~100 μm each layer) with known attenuation coefficient on the range of 0.9 to 2.32 mm?1. It is shown that the estimated depth‐resolved attenuation coefficient recovers the reference values, measured by using an integrating sphere followed by the inverse adding doubling processing technique. That was corroborated for all situations when the correct transmittance value is used with an average difference of 7%. Finally, we applied the proposed method to estimate the depth‐resolved attenuation coefficient for a thin biological sample, demonstrating the ability of our method on real OCT images.  相似文献   

13.
Methods of nonlinear optics provide a vast arsenal of tools for label‐free brain imaging, offering a unique combination of chemical specificity, the ability to detect fine morphological features, and an unprecedentedly high, subdiffraction spatial resolution. While these techniques provide a rapidly growing platform for the microscopy of neurons and fine intraneural structures, optical imaging of astroglia still largely relies on filament‐protein‐antibody staining, subject to limitations and difficulties especially severe in live‐brain studies. Once viewed as an ancillary, inert brain scaffold, astroglia are being promoted, as a part of an ongoing paradigm shift in neurosciences, into the role of a key active agent of intercellular communication and information processing, playing a significant role in brain functioning under normal and pathological conditions. Here, we show that methods of nonlinear optics provide a unique resource to address long‐standing challenges in label‐free astroglia imaging. We demonstrate that, with a suitable beam‐focusing geometry and careful driver‐pulse compression, microscopy of second‐harmonic generation (SHG) can enable a high‐resolution label‐free imaging of fibrillar structures of astrocytes, most notably astrocyte processes and their endfeet. SHG microscopy of astrocytes is integrated in our approach with nonlinear‐optical imaging of red blood cells based on third‐harmonic generation (THG) enhanced by a three‐photon resonance with the Soret band of hemoglobin. With astroglia and red blood cells providing two physically distinct imaging contrasts in SHG and THG channels, a parallel detection of the second and third harmonics enables a high‐contrast, high‐resolution, stain‐free stereoimaging of gliovascular interfaces in the central nervous system. Transverse scans of the second and third harmonics are shown to resolve an ultrafine texture of blood‐vessel walls and astrocyte‐process endfeet on gliovascular interfaces with a spatial resolution within 1 μm at focusing depths up to 20 μm inside a brain.  相似文献   

14.
A compact high‐speed full‐field optical coherence microscope has been developed for high‐resolution in vivo imaging of biological tissues. The interferometer, in the Linnik configuration, has a size of 11 × 11 × 5 cm3 and a weight of 210 g. Full‐field illumination with low‐coherence light is achieved with a high‐brightness broadband light‐emitting diode. High‐speed full‐field detection is achieved by using part of the image sensor of a high‐dynamic range CMOS camera. En face tomographic images are acquired at a rate of 50 Hz, with an integration time of 0.9 ms. The image spatial resolution is 0.9 μm × 1.2 μm (axial × transverse), over a field of view of 245 × 245 μm2. Images of human skin, revealing in‐depth cellular‐level structures, were obtained in vivo and in real‐time without the need for stabilization of the subject. The system can image larger fields, up to 1 × 1 mm2, but at a reduced depth.   相似文献   

15.
Polymer‐based nanoparticles (NPs) can be efficiently used for the delivery of bioactive molecules for both in vitro and in vivo applications affording high drug loading and controlled release profiles. Within this framework polylactic‐co‐glycolic acid (PLGA) NPs with a diameter of 290 ± 41 nm have been fabricated and loaded with dexamethasone (DXM) using a patented procedure. The aim of the project was to setup a controlled delivery system to promote the in vitro differentiation of Human Gingival Fibroblasts (HGFs). First the uptake of fluorescent PLGA NPs by HGFs cells was investigated; then experiments were also addressed to analyze the specific cell response to DXM, in order to evaluate its functional efficiency in comparison with its conventional addition to the culture medium. The results showed that cells treated with DXM‐loaded NPs acquired the osteoblast phenotype faster in comparison to those treated with the free drug. The slow and sustained release of DXM from PLGA NPs produced a constant and uniform concentration of drug inside cells with long‐term and enhanced biochemical effects. © 2015 American Institute of Chemical Engineers Biotechnol. Prog., 31:1381–1387, 2015  相似文献   

16.
A cryogenic optical waveguide spectrometer that uses a Teflon-AF 2400 liquid core waveguide is described. In comparison to standard low-temperature absorption techniques, the liquid core waveguide approach not only affords the use of microliter samples but also provides significant improvements in sensitivity. Here we show low-temperature absorption spectra of various flavoproteins, including DNA photolyase, measured using this new technique. The technique has high reproducibility and can afford the detection of 15 ng of flavoprotein. In addition, the technique requires several hundredfold less protein than standard low-temperature techniques for the same sensitivity. The performance of the spectrometer in the ultraviolet (UV) region is investigated experimentally and compared with standard UV absorption techniques. Results indicate that, below 300 nm, the observed absorbances deviate from the Beer-Lambert law.  相似文献   

17.
Monitoring ecosystem functions in forests is a priority in a climate change scenario, as climate‐induced events may initially alter the functions more than slow‐changing attributes, such as biomass. The ecosystem functional properties (EFPs) are quantities that characterize key ecosystem processes. They can be derived by point observations of gas and energy exchanges between the ecosystems and the atmosphere that are collected globally at FLUXNET flux tower sites and upscaled at ecosystem level. The properties here considered describe the ability of ecosystems to optimize the use of resources for carbon uptake. They represent functional forest information, are dependent on environmental drivers, linked to leaf traits and forest structure, and influenced by climate change effects. The ability of vegetation optical depth (VOD) to provide forest functional information is investigated using 2011–2014 satellite data collected by the Soil Moisture and Ocean Salinity mission and using the EFPs as reference dataset. Tropical forests in Africa and South America were analyzed, also according to ecological homogeneous units. VOD jointly with water deficit information explained 93% and 87% of the yearly variability in both flux upscaled maximum gross primary productivity and light use efficiency functional properties, in Africa and South America forests respectively. Maps of the retrieved properties evidenced changes in forest functional responses linked to anomalous climate‐induced events during the study period. The findings indicate that VOD can support the flux upscaling process in the tropical range, affected by high uncertainty, and the detection of forest anomalous functional responses. Preliminary temporal analysis of VOD and EFP signals showed fine‐grained variability in periodicity, in signal dephasing, and in the strength of the relationships. In selected drier forest types, these satellite data could also support the monitoring of functional dynamics.  相似文献   

18.
A full quantitative evaluation of the depolarization of light may serve to assess concentrations of depolarizing particles in the retinal pigment epithelium and to investigate their role in retinal diseases in the human eye. Optical coherence tomography and optical frequency domain imaging use spatial incoherent averaging to compute depolarization. Depolarization depends on accurate measurements of the polarization states at the receiver but also on the polarization state incident upon and within the tissue. Neglecting this dependence can result in artifacts and renders depolarization measurements vulnerable to birefringence in the system and in the sample. In this work, we discuss the challenges associated with using a single input polarization state and traditional depolarization metrics such as the degree‐of‐polarization and depolarization power. We demonstrate quantitative depolarization measurements based on Jones vector synthesis and polar decomposition using fiber‐based polarization‐sensitive optical frequency domain imaging of the retinal pigment epithelium in a human eye.   相似文献   

19.
We introduce a Doppler OCT (DOCT) platform that is fully synchronized with the heart‐beat via a pulse oximeter. The system allows reconstructing heart‐beat‐phase‐coherent quantitative DOCT volumes. The method is to acquire a series of DOCT volumes and to record the pulse in parallel. The heartbeat data is used for triggering the start of each DOCT volume acquisition. The recorded volume series is registered to the level of capillaries using a cross‐volume registration. The information of the pulse phase is used to rearrange the tomograms in time, to obtain a series of phase coherent DOCT volumes over a pulse. We present Doppler angle independent quantitative evaluation of the absolute pulsatile blood flow within individual retinal vessels as well as of the total retinal blood flow over a full heartbeat cycle. (© 2013 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

20.
Temporally low‐coherent optical diffraction tomography (ODT) is proposed and demonstrated based on angle‐scanning Mach‐Zehnder interferometry. Using a digital micromirror device based on diffractive tilting, the full‐field interference of incoherent light is successfully maintained during every angle‐scanning sequences. Further, current ODT reconstruction principles for temporally incoherent illuminations are thoroughly reviewed and developed. Several limitations of incoherent illumination are also discussed, such as the nondispersive assumption, optical sectioning capacity and illumination angle limitation. Using the proposed setup and reconstruction algorithms, low‐coherent ODT imaging of plastic microspheres, human red blood cells and rat pheochromocytoma cells is experimentally demonstrated.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号