首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This work presents the results of the study of airborne bacteria in a kindergarten in Gliwice, Upper Silesia, Poland. In this study, the samples of bioaerosols were collected using six-stage Andersen cascade impactor (with aerodynamic cutoff diameters 7.0, 4.7, 3.3, 2.1, 1.1, and 0.65 μm). The level of culturable bacterial aerosols indoors was about 3000 CFU m?3—six to eight times higher than outdoors. In the classrooms, respirable bacterial particles, <4.7 µm, contributed up to 85 % of the total number of culturable bacteria, increasing the possible adverse health effects due to their inhalation. The identification of the bacterial species showing the dominance of gram-positive cocci in the indoor environment and non-sporing gram-positive rods in the outdoor air indicates that most of the bacteria present in the studied kindergarten are human origin. Using the obtained data, the nursery school exposure dose (NSED) of bioaerosols was estimated for the children and personnel of this kindergarten (nursery school). The highest value of NSED was obtained for younger children (930 CFU kg?1) compared to older children (about 600 CFU kg?1) and to the kindergarten staff (about 300 CFU kg?1). This result suggests the elevated risk of adverse health effects in younger children exposed to the bioaerosols in the kindergarten, including infections.  相似文献   

2.
Monitoring campaigns in two different seasons were carried out at two underground stations (Tacubaya and Azcapotzalco) of the subway of Mexico City, in order to assess airborne bacterial and fungi concentrations, as well as their relationship with several factors, such as depth of the station, sampling site, temperature, and relative humidity. Sixteen sampling sites were selected according to the depth of the lines and the transit of passengers in the corridors, concourses, and platforms. In addition, samples were also collected in the carriages when they were in movement. Outdoor samples were taken at the two stations for comparison. Two-stage multi-orifice cascade impactors were used to collect aerobiological particles, and with the aid of macroscopic and microscopic characterization were found 57 fungi and 61 bacteria colonies. Outdoor bacteria concentrations ranged from 1 to 68 CFU m?3, while fungi concentrations varied from 6 to 80 CFU m?3. The indoor concentration levels of bacteria and fungi ranged from 1 to 484 CFU m?3 and from 51 to 715 CFU m?3, respectively. Fungi and bacteria indoor concentrations in the subway were higher than outdoor, up to 8 times. Most of bacteria were identified as Gram-positive nonsporulating short bacillus, while the most abundant fungi genera identified were Aspergillus, Penicillium, and Alternaria in that order of frequency. Statistical analysis showed significant differences between the stations and the lines of different depths, showing a greater microorganisms’ concentration with a greater depth. Although bacteria and fungi concentrations were higher in the spring than in winter, this difference was not significant. Even if indoor microbiological pollution in underground stations was higher than outdoor, the concentrations found in this study were lower than indoor air international standards.  相似文献   

3.
A comprehensive survey of airborne fungi has been lacking for the Sydney region. This study determined the diversity and abundance of outdoor airborne fungal concentrations in urban Sydney. Monthly air samples were taken from 11 sites in central Sydney, and culturable fungi identified and quantified. The genus Cladosporium was the most frequently isolated fungal genus, with a frequency of 78 % and a mean density of 335 CFU m?3. The next most frequently encountered genus was Alternaria, occurring in 53 % of samples with a mean of 124 CFU m?3. Other frequently identified fungi, in decreasing occurrence, were as follows: Penicillium, Fusarium, Epicoccum, Phoma, Acremonium and Aureobasidium. Additionally, seasonal and spatial trends of airborne fungi were assessed, with increases in total culturable fungal concentrations experienced in the summer months. The correspondence between a range of key environmental variables and the phenology of airborne fungal propagules was also examined, with temperature, wind speed and proximal greenspace having the largest influence on fungal propagule density. If the greenspace was comprised of grass, stronger associations with fungal behaviour were observed.  相似文献   

4.
The more the mold species isolated on a culture medium, the more the sampling environment is represented accurately. According to the sampling purpose, it is crucial to use the best culture medium for mold. However, no study is available regarding the comparison of dichloran rose bengal chloramphenicol (DRBC) and Sabouraud dextrose agar with cycloheximide and chloramphenicol (SDA-CHX-CHL) culture media in terms of their application for airborne sampling, isolation, and identification of fungi. Airborne mold samples were impacted onto both DRBC and SDA-CHX-CHL, simultaneously using single-stage Andersen sampler. The limit of detection (LOD) value for airborne mold count was 7 CFU m?3 (1 colony growth on the Petri dish). The total mold counts (TMC) ranged between <7 and 504 CFU m?3 (med 56 CFU m?3) and <7 and 1218 CFU m?3 (med 259 CFU m?3), collected on SDA-CHX-CHL and DRBC, respectively. Significantly higher TMC were observed on DRBC than on SDA regardless of the sampling environment (i.e, indoor or outdoor) (p < 0.05). Among the most predominant mold genera, observation frequencies of Penicillium spp. and Aspergillus spp. on both culture media were found to be more than 70%. Observation frequencies of Cladosporium spp., Alternaria spp., and yeast were found to be higher in samples collected on DRBC than those on SDA-CHX-CHL. Finally, DRBC was found to be superior to SDA in terms of both number of colonies and number of genera isolated from the air.  相似文献   

5.
Alfresco (def. clean, outdoor) airborne bacteria were collected with a commercially available wet-cyclone bioaerosol sampler to demonstrate its use, sample processing and resultant observations of total and culturable bacteria in mid-summer in the mid-Willamette River Valley, OR. Some critiques of the system are given. The maximum and minimum total and culturable airborne bacterial concentrations in the samples were 5.9 × 105 and 8.8 × 102 cells m−3, and 1.3 × 104 and 3.1 CFU m−3, respectively. What is thought to be a diurnal cycle was also observed for both fractions with highest concentrations during the day and lowest at dawn and dusk. The culturable bacteria as a percentage of the total, was maximal at mid-day (≈ 3%) and minimal at early morning and late evening (≈ 0.5–2%). Contrarily, the total bacteria in the downwind dust plume of a grass seed combine was 2.9 × 106 cells m−3 and of these approximately 73% were culturable, a much greater culturable percentage than found in the alfresco outdoor atmosphere.  相似文献   

6.
The concentration and distribution characteristics of airborne fungi were investigated in indoor and outdoor air of two metro stations (Imam Khomeini and Sadeghiyeh stations) in Tehran subway. Samples were taken from indoor air at each station from platform and ticket office area also from adjacent outdoor air of each station. Indoor sampling was conducted for two types of trains, old and new. The concentration of airborne fungi ranged from 21 CFU/m3 at the outdoor air of Imam Khomeini station to 1,402 CFU/m3 in the air samples collected from the platform of this station. Results showed that airborne fungi concentrations at indoor air were higher than the outdoor air (p < 0.05), and fungal levels significantly correlated with the number of passengers (p < 0.05; r = 0.68) and RH % (p < 0.05; r = 0.43). Sixteen genera of fungi were isolated in all sampled environments. The predominant genera identified in indoor and outdoor air were Penicillium spp. (34.88 % of total airborne fungi) and Alternaria spp. (29.33 % of total airborne fungi), respectively. The results of this study showed that the indoor air quality in subway is worse than the outdoor air.  相似文献   

7.
The characterization of indoor (a naturally ventilated office) and outdoor (adjacent courtyard) metals in PM2.5 during a winter period in Xi'an, China were carried out. The results indicated that the average mass concentrations of PM2.5 in indoor and outdoor environments all exceeded the daily average limit of 75 µg m–3 set by the Chinese government. The dominant metals in PM2.5 were Ca, Al, Zn, Mg, Fe, and Pb in both indoor and outdoor air. Concentration of As was much higher than the standard of 6 ng m–3 issued by the government. Enrichment factor analysis showed that anthropogenic emissions might be the primary sources of As, Cd, Pb, and Zn, while crust was the main origin of Co. A majority of indoor-to-outdoor concentration ratios of metal were lower than 1 indicating mostly the contribution of outdoor sources rather than indoor ones. As and Cr in both indoor and outdoor air posed the highest noncarcinogenic and carcinogenic risks, respectively. The noncarcinogenic and carcinogenic risks were 2.74 and 2.54 × 10?4 indoor and 4.04 and 3.87 × 10?4 outdoor, which suggested that possible adverse health effects should be of concern.  相似文献   

8.

In recent years, monitoring of airborne bacteria and fungi concentrations has obtained increasing universal attraction not only for influences on ecological balance but also for evaluating their public health consequences. In this study, we aimed to investigate culturable airborne bacteria and fungi levels in different sites of Abadan, and their association with meteorological parameters and PM2.5 levels. Abadan is one of the most industrialized cities in the southwest of Iran where over the current decade has experienced lots of dust storm episodes. In total, 400 air samples were collected in 6 months (autumn and winter) using a single-stage viable Andersen cascade impactor for sampling airborne bacteria and fungi and portable DustTrak Aerosol Monitor 8520 for measuring PM2.5 concentrations and meteorological parameters. Microbial concentrations showed a significant difference between various sites over the study period with averages of 569.57?±?312.64 and 482.73?±?242.86 CFU/M3 for bacteria and fungi, respectively. The air temperature had a significant effect on the concentration of both airborne bacteria and fungi. A significant positive correlation between relative humidity and fungi but no correlation between relative humidity and bacteria concentrations were observed. The average airborne PM2.5 concentrations of all sites among the study period was 93.24?±?116.72 μg/m3. The atmospheric bacterial and fungal communities were strongly positively correlated with the ambient PM2.5 level. The levels of airborne bacteria and fungi along with PM2.5 in the air of the city were relatively higher than the recommended levels. Therefore, the best course of action is needed to control emission sources. Further studies are also needed to evaluate the clinical analysis of the health effects of exposure to these pollutants.

  相似文献   

9.
We examined 12,026 fungal air samples (9,619 indoor samples and 2,407 outdoor samples) from 1,717 buildings located across the United States; these samples were collected during indoor air quality investigations performed from 1996 to 1998. For all buildings, both indoor and outdoor air samples were collected with an Andersen N6 sampler. The culturable airborne fungal concentrations in indoor air were lower than those in outdoor air. The fungal levels were highest in the fall and summer and lowest in the winter and spring. Geographically, the highest fungal levels were found in the Southwest, Far West, and Southeast. The most common culturable airborne fungi, both indoors and outdoors and in all seasons and regions, were Cladosporium, Penicillium, nonsporulating fungi, and Aspergillus. Stachybotrys chartarum was identified in the indoor air in 6% of the buildings studied and in the outdoor air of 1% of the buildings studied. This study provides industrial hygienists, allergists, and other public health practitioners with comparative information on common culturable airborne fungi in the United States. This is the largest study of airborne indoor and outdoor fungal species and concentrations conducted with a standardized protocol to date.  相似文献   

10.
Endotoxins are components of Gram-negative bacteria with inherently high pro-inflammatory potential. In an urban environment, airborne endotoxins may associate with pollutants such as particulate matter, increasing the severity of the immune response by acting as a natural adjuvant to augment inflammatory respiratory disease development. Here, we present a closer look at outdoor urban endotoxins by applying a microbial-targeted collection strategy. Results from 87 samples distributed throughout the city of Antwerp ranged from 0.45 to 93.71 EU/m3, with a geometric mean of 4.49 EU/m3 and 95% confidence interval of 3.53–5.71 EU/m3. Sample collection was also coupled with the use of a Coulter counter, for which the particle count (2.5–10 μm/m3) showed a significant correlation with endotoxin concentration (R2?=?0.24; p?<?0.0001; n?=?64). In addition, the analysis of the cultivable bacterial colony-forming units on Reasoner’s 2A agar (expressed CFU/m3) showed to be a good indicator for airborne endotoxins (R2?=?0.57; p?<?0.0001; n?=?58). Moreover, identification of dominant bacterial colonies on these culture plates gave some indications on potential sources of these urban outdoor bacteria and endotoxins.  相似文献   

11.
Y. Xia  F. Conen  C. Alewell 《Aerobiologia》2013,29(1):153-159
Over a period from June to October 2010, we carried out four short campaigns on the northern alpine ridge (High Altitude Research Station Jungfraujoch, 3,450 m above sea level) to determine bacterial number concentrations by collecting aerosol with liquid impingers, followed by filtration, fluorescent staining and counting with a microscope. Impinger liquid was also subjected to drop freeze tests to determine the number of ice nucleators. Parallel measurements of 222Rn enabled us to distinguish air masses with no, or little, recent land surface contact (free troposphere, 222Rn ≤ 0.50 Bq m?3) from air masses influenced by recent contact with land surface (222Rn > 0.50 Bq m?3). In free tropospheric air, concentration of total bacteria was on average 3.4 × 104 cells m?3 (SD = 0.8 × 104 cells m?3). When wind conditions preceding sampling were calm, or when the station was in clouds during sampling, there was no detectable difference in bacterial number concentrations between free tropospheric air and air influenced by recent land surface contact. One campaign was preceded by a storm. Here, recent land surface contact had enriched the air in bacterial cells (up to 7.5 × 104 cells m?3). Very few of these bacteria may act as ice nucleators in clouds. The median ratio of ice nucleators to the number of bacterial cells in our study was 1.0 × 10?5. We conclude that injection of bacterial cells into the free troposphere is an intermittent process. Conditions controlling the release of bacteria into near surface air are probably more of a limiting factor than vertical transport and mixing of near surface air into the free troposphere.  相似文献   

12.
Culturable Airborne Bacteria in Outdoor Environments in Beijing,China   总被引:5,自引:0,他引:5  
Fang Z  Ouyang Z  Zheng H  Wang X  Hu L 《Microbial ecology》2007,54(3):487-496
Airborne bacteria are important biological components of bioaerosol and play an important role in ecosystem. Bacteria at a high concentration in the atmosphere can result in biological air pollution and all kinds of diseases. In this study, a systematical survey on the culturable airborne bacteria was carried out for 1 year at three sites in Beijing urban area. Results showed that concentrations of culturable bacteria ranged from 71 colony forming units (CFU)/m3 to 22,100 CFU/m3, and the mean was 2,217 CFU/m3. Bacterial concentrations at the human activity-enriched site (RCEES) and the highly trafficked site (XZM) were virtually the same point. They were significantly higher than those at the greener site (BBG). Significant variation in bacterial concentrations in different seasons was observed at RCEES and XZM with higher concentrations in summer and autumn. In a single day, significantly lower concentrations were detected at 13:00 hours through all sampling sites. In this study, 165 species in 47 genera of culturable bacteria were identified. Micrococcus was one of the most dominant bacterial groups and contributed to approximately 20∼30% of the total bacterial concentration, followed by Staphylococcus, Bacillus, Corynebacterium, and Pseudomonas. The bacterial species with a high concentration percentage included Micrococcus luteus and Micrococcus roseus.  相似文献   

13.
We examined 12,026 fungal air samples (9,619 indoor samples and 2,407 outdoor samples) from 1,717 buildings located across the United States; these samples were collected during indoor air quality investigations performed from 1996 to 1998. For all buildings, both indoor and outdoor air samples were collected with an Andersen N6 sampler. The culturable airborne fungal concentrations in indoor air were lower than those in outdoor air. The fungal levels were highest in the fall and summer and lowest in the winter and spring. Geographically, the highest fungal levels were found in the Southwest, Far West, and Southeast. The most common culturable airborne fungi, both indoors and outdoors and in all seasons and regions, were Cladosporium, Penicillium, nonsporulating fungi, and Aspergillus. Stachybotrys chartarum was identified in the indoor air in 6% of the buildings studied and in the outdoor air of 1% of the buildings studied. This study provides industrial hygienists, allergists, and other public health practitioners with comparative information on common culturable airborne fungi in the United States. This is the largest study of airborne indoor and outdoor fungal species and concentrations conducted with a standardized protocol to date.  相似文献   

14.
Thailand border market is where the local Thais, Cambodians, Laotians, and Burmeses exchange their goods and culture at the border checkpoints. It is considered to be the source of aerial disease transmission especially for foreigners because it is always very crowded with people from all walks of life. Unhealthy air quality makes this area high risk of spread of airborne diseases. This study assessed airborne concentrations of bacteria and fungi in a border market to improve exposure estimates and develop efficient control strategies to reduce health risk. The density and distribution of airborne bacteria and fungi were investigated in the Chong Chom border market in Surin Province, Thailand. Eighteen air sampling sites were taken from outdoors and various work environments including indoor footpaths, wooden handicraft shops, electronic shops, the secondhand clothing shops, and fruit market areas. Exposed Petri plate method and liquid impinger sampler were used for sampling at the breathing zone, 1.5 m above the floor level, during weekend and holiday. Meteorological factors such as relative humidity, temperature, and light intensity were collected by portable data logger. The relative humidity was 67–73%, and temperature 29–33°C, and light varied between 18 and 270 Lux m−2. Gram-positive and Gram-negative bacteria were found at a mean value of 104 CFU m−3, and airborne fungi of 103 CFU m−3 were recorded. The highest concentration of culturable airborne microorganisms was found along the indoor footpath (9.62 × 104 CFU m−3 and 750.00 CFU/plate/h for impingement and sedimentation methods, respectively), the fruit market area (7.86 × 104 CFU m−3 and 592.42 CFU/plate/h for impingement and sedimentation methods, respectively), and the secondhand clothing shop (4.59 × 103 CFU m−3 and 335.42 CFU/plate/h for impingement and sedimentation methods, respectively) for Gram-positive bacteria, Gram-negative bacteria, and fungi, respectively. The lowest concentration of Gram-positive bacteria, Gram-negative bacteria, and fungi was found only at the outdoor area at 1.53 × 104 CFU m−3, 0.93 × 104 CFU m−3 and 0.80 × 103 CFU m−3 by means of impingement method and 136.67 CFU/plate/h, 69.25 CFU/plate/h, and 62.00 CFU/plate/h by means of sedimentation methods for Gram-positive bacteria, Gram-negative bacteria, and fungi, respectively. The most frequently present airborne bacteria were identified as Bacillus, Corynebacteria, Diplococcus, Micrococcus, Acinetobacter, Alcaligenes, Enterobacter, and spore former rods. Acremonium, Aspergillus, Cladosporium, Penicillium, and Sporotrichum were the most frequently found aerosol fungi genera. The distribution of airborne microorganisms correlated with relative humidity and light factors based on principal component analysis. In conclusion, the border market is a potential source of aerial disease transmission and a various hazards of bioaerosols for workers, consumers, sellers, and tourists. The bioaerosol concentration exceeded the standard of occupational exposure limit. Many major indicators of allergenic and toxigenic airborne bacteria and fungi, Acinetobacter, Enterobacter, Pseudomonas, Cladosporium, Alternaria, Aspergillus, and Penicillium, were found in the various market environments.  相似文献   

15.
There has been renewed interest in the combined use of high-rate algal ponds (HRAP) for wastewater treatment and biofuel production. Successful wastewater treatment requires year-round efficient nutrient removal while high microalgal biomass yields are required to make biofuel production cost-effective. This paper investigates the year-round performance of microalgae in a 5-ha demonstration HRAP system treating primary settled wastewater in Christchurch, New Zealand. Microalgal performance was measured in terms of biomass production, nutrient removal efficiency, light absorption and photosynthetic potential on seasonal timescales. Retention time-corrected microalgal biomass (chlorophyll a) varied seasonally, being lowest in autumn and winter (287 and 364 mg m?3day?1, respectively) and highest in summer (703 mg m?3day?1), while the conversion efficiency of light to biomass was greatest in winter (0.39 mg Chl- a per μmol) and lowest in early summer (0.08 mg Chl- a per μmol). The percentage of ammonium (NH4–N) removed was highest in spring (79 %) and summer (77 %) and lowest in autumn (47 %) and winter (53 %), while the efficiency of NH4–N removal per unit biomass was highest in autumn and summer and lowest in winter and spring. Chlorophyll-specific light absorption per unit biomass decreased as total chlorophyll increased, partially due to the package effect, particularly in summer. The proportional increase in the maximum electron transport rate from winter to summer was significantly lower than the proportional increase in the mean light intensity of the water column. We concluded that microalgal growth and nutrient assimilation was constrained in spring and summer and carbon limitation may be the likely cause.  相似文献   

16.
The aim of this study was to estimate the indoor and outdoor concentrations of fungal spores in the Metropolitan Area of Sao Paulo (MASP), collected at different sites in winter/spring and summer seasons. The techniques adopted included cultivation (samples collected with impactors) and microscopic enumeration (samples collected with impingers). The overall results showed total concentrations of fungal spores as high as 36,000 per cubic meter, with a large proportion of non culturable spores (around 91% of the total). Penicillium sp. and Aspergillus sp. were the dominant species both indoors and outdoors, in all seasons tested, occurring in more than 30% of homes at very high concentrations of culturable airborne fungi [colony forming units(CFU) m−3]. There was no significant difference between indoor and outdoor concentrations. The total fungal spore concentration found in winter was 19% higher than that in summer. Heat and humidity were the main factors affecting fungal growth; however, a non-linear response to these factors was found. Thus, temperatures below 16°C and above 25°C caused a reduction in the concentration (CFU m−3) of airborne fungi, which fits with MASP climatalogy. The same pattern was observed for humidity, although not as clearly as with temperature given the usual high relative humidity (above 70%) in the study area. These results are relevant for public health interventions that aim to reduce respiratory morbidity among susceptible populations.  相似文献   

17.
The emission of the airborne bacteria and fungi from an indoor wastewater treatment station adopting an integrated oxidation ditch with a vertical circle was investigated. Microbial samples were collected by the six-stage viable Andersen cascade impactor, and the samples were collected in triplicate in each sampling site per season. Culture-based method was applied to determine the concentrations of the airborne bacteria and fungi, while the cloning/sequencing method was used to characterize the genetic structure and community diversity of airborne bacteria. The highest concentrations of airborne bacteria (4155 ± 550 CFU/m3) and fungi (883 ± 150 CFU/m3) were obtained in June (summer). The lowest concentration of bacteria (1458 ± 434 CFU/m3) was determined in January (winter), and the lowest concentration of fungi (169 ± 40 CFU/m3) was found in March (spring), respectively. The particle size distribution analysis showed that most culturable bacteria obtained in all the sampling sites were in the particle size range of 1.1–4.7 µm. Most culturable fungi had particle sizes in the range 1.1–3.3 µm. Microbial population analysis showed that Bacillus sp., Acinetobacter sp., and Lysinibacillus were the main groups obtained in S1. Enterobacter was the dominant group in sampling site S2. Both the concentrations and particle size distribution of the bioaerosols in the enclosed space presented a seasonal and site-related variation. Concentration and richness of microorganisms in bioaerosols in June were higher than in September and January. The particle size distribution varied between the sampling sites, and proportion of large particles was higher in S2 than in S1 because of the settlement of large particles. Pathogenic species, such as Acinetobacter lwoffii, Staphylococcus saprophyticus, and Enterobacter sp., were isolated from the bioaerosols, which could pose serious latent danger to sewage workers’ health.  相似文献   

18.
Vibrios are among the most abundant culturable microbes in aquatic environments. They can be either free-living in the water column or associated with several marine organisms as mutualists, saprophytes, or parasites. In the present study we analysed vibrios abundance and diversity in the mucus of the polychaete Myxicola infundibulum, complementing culture-based with molecular methods. Vibrios reached 4.6?×?103 CFU mL?1 thus representing a conspicuous component of the heterotrophic culturable bacteria. In addition, luminous vibrios accounted for about 60 % of the total culturable vibrios in the mucus. The isolates were assigned to: Vibrio gigantis, Vibrio fischeri, Vibrio jasicida, Vibrio crassostreae, Vibrio kanaloae, and Vibrio xuii. Two Vibrio isolates (MI-13 and MI-15) may belong to a new species. We also tested the ability of the Vibrio isolates to grow on M. infundibulum mucus as the sole carbon source. All strains showed appreciable growth in the presence of mucus, leading us to conclude that this matrix, which is abundant and covers the animal entirely, may represent a microcosm and a food source for some bacteria, playing a crucial role in the structuring of a mucus-associated beneficial microbial community. Moreover, the trophic relationship between vibrios and M. infundibulum mucus could be enhanced by the protection that mucus offers to vibrios. The results of this study represent a contribution to the growing evidence for complex and dynamic invertebrate-microbe associations present in nature and highlight the importance of exploring relationships that Vibrio species establish with marine invertebrates.  相似文献   

19.
Lake Pääjärvi, a boreal Finnish lake, was investigated in winter for weather conditions, structure and thickness of ice and snow, solar radiation, and under-ice current and temperature. Heat budget of Lake Pääjärvi in January–March was governed by terrestrial radiation losses of 20–35 W m?2 recompensed by ice growth of 0.5–1.0 cm day?1. In April, snow melted, albedo decreased from 0.8 to <0.1, and the mean ice melt rate was 1.5 cm day?1. Internal melting and surface melting were about equal. The mean turbulent heat loss was small. The heat flux from the water to ice was about 5 W m?2 in winter, increasing to 12 W m?2 in the melting season. The light attenuation coefficient was 1.1 m?1 for the congelation ice (black ice) in winter, compared with 1.5 m?1 for the lake water, and it was up to 3 m?1 for candled congelation ice in spring, and about 10 m?1 for superimposed ice (white ice) and snow. Gas bubbles were the main factor that reduced the transparency of ice. The radiation penetrating the ice heated the water body causing convective currents and horizontal heat transfer. This increased the temperature of the water body to about 3°C before the ice break-up. After the snow had melted, the euphotic depth (the depth of 1% surface irradiance) was estimated as 2.0 m, only two-thirds that in summer.  相似文献   

20.
Inhalation of airborne microorganisms and organic dust is an occupational concern among workers in agricultural industries. Airborne microorganisms and particulate matter samples were collected from poultry house, flourmill, textile, and food industry sites by use of liquid impinger and gravimetric samplers. Particulate matter concentrations were recorded at median concentrations of 1.56, 1.92, 4.39, and 0.7 mg/m3 in the occupied poultry house, textile, flourmill, and food indoor working environments, respectively. The highest median particulate matter concentration (27.9 mg/m3) was detected at the flourmill’s stack site. The highest median indoor concentration of culturable airborne bacteria (6.23 × 105 CFU/m3) was found at the occupied poultry-house site and the lowest concentration (4.6 × 103 CFU/m3) was found at the food industry site. The highest median indoor concentration of culturable airborne fungi (3.15 × 104 CFU/m3) was found at the flourmill site whereas the lowest (1.24 × 103 CFU/m3) was found at the textile industry site. Bacillus and Staphylococcus were the predominant Gram-positive bacteria whereas Acinetobacter and Klebsiella were the predominant Gram-negative bacteria. Escherichia coli and Salmonella were only detected in the indoor air at the poultry house site. Aspergillus flavus, Aspergillus niger, Penicillium, and yeast were the predominant fungal types at flourmill, textile, food industry, and poultry house, respectively. Workers were continuously exposed to airborne microorganisms at a median value of 104 CFU/m3 in all the industries studied.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号