1.
This study aimed to improve understanding of the mechanical aspects of cemented implant loosening. After aggressive fatigue loading of stem/cement/femur constructs, micro-cracks and stem/bone micro-motions were quantified to answer three research questions: Are cracks preferentially associated with the stem/cement interface, the cement/bone interface or voids? Is cement damage dependent on axial position? Does cement damage correlate with micro-motion between the stem and the bone? Eight Charnley Cobra stems were implanted in cadaveric femora. Six stem/cement/femur constructs were subjected to "stair-climbing" loads for 300 kcycles at 2Hz. Loads were normalized by construct stiffness to avoid fracture. Two additional constructs were not loaded. Transverse sections were cut at 10mm intervals, stained with a fluorescent dye penetrant and examined using epi-fluorescence stereomicroscopy. Crack lengths and cement areas were recorded for 9 sections per specimen. Crack length-density was calculated by dividing summed crack length by cement mantle area. To isolate the effect of loading, length-density data were offset by the baseline length-density measured in the non-loaded specimens. Significantly more cracks were associated with the interdigitated area (35.1%+/-11.6%) and the cement/bone interface (31.0%+/-6.2%) than with the stem/cement interface (11.0%+/-5.2%) or voids (6.1%+/-4.8%) (p<0.05). Load-induced micro-crack length-density was significantly dependent on axial position, increasing proximally (p<0.001). Micro-motions were small, all stems rotated internally. Cement damage did not correlate with micro-motion.  相似文献   

2.
Experimental models can be used for pre-clinical testing of cemented and other type of hip replacements. Total hip replacement (THR) failure scenarios include, among others, cement damage accumulation and the assessment of accurate stress and strain magnitudes at the cement mantle interfaces (stem-cement and cement-bone) can be used to predict mechanical failure. The aseptic loosening scenario in cemented hip replacements is currently not fully understood, and methods of evaluating medical devices must be developed to improve clinical performance. Different results and conclusions concerning the cement micro-cracking mechanism have been reported.The aim of this study was to verify the in vitro behavior of two cemented femoral stems with respect to fatigue crack formation. Fatigue crack damage was assessed at the medial, lateral, anterior and posterior sides of the Lubinus SPII and Charnley stems. All stems were loaded and tested in stair climbing fatigue loading during one million cycles at 2 Hz. After the experiments each implanted synthetic femur was sectioned and analyzed. We observed more damage (cracks per area) for the Lubinus SPII stem, mainly on the proximal part of the cement mantle. The micro-cracking formation initiated in the stem–cement interface and grew towards the direction of cortical bone of the femur.Overall, the cement–bone interface seems to be crucial for the success of the hip replacement. The Charnley stem provoked more damage on the cement–bone interface. A failure index (maximum length of crack/maximum thickness of cement) considered was higher for the cement–stem interface of the Lubinus SPII stem. For a cement mantle thickness higher than 5 mm, cracking initiated at the cement–bone interface and depended on the opening canal process (reaming procedure and instrumentation). The analysis also showed that fatigue-induced damage on the cement mantle, increasing proximally, and depended on the axial position of the stem. The cement thickness is an important factor for the success of THR and this study evidenced that cement thickness higher than 2 mm apparently does not affect the mechanical behavior of the cement mantel and induce more crack formation on the cement–bone interface.  相似文献   

3.
The goal of this study was to quantify the micromechanics of the cement–bone interface under tensile fatigue loading using finite element analysis (FEA) and to understand the underlying mechanisms that play a role in the fatigue behavior of this interface. Laboratory cement–bone specimens were subjected to a tensile fatigue load, while local displacements and crack growth on the specimen's surface were monitored. FEA models were created from these specimens based upon micro-computed tomography data. To accurately model interfacial gaps at the interface between the bone and cement, a custom-written erosion algorithm was applied to the bone model. A fatigue load was simulated in the FEA models while monitoring the local displacements and crack propagation. The results showed the FEA models were able to capture the general experimental creep damage behavior and creep stages of the interface. Consistent with the experiments, the majority of the deformation took place at the contact interface. Additionally, the FEA models predicted fatigue crack patterns similar to experimental findings. Experimental surface cracks correlated moderately with FEA surface cracks (r2=0.43), but did not correlate with the simulated crack volume fraction (r2=0.06). Although there was no relationship between experimental surface cracks and experimental creep damage displacement (r2=0.07), there was a strong relationship between the FEA crack volume fraction and the FEA creep damage displacement (r2=0.76). This study shows the additional value of FEA of the cement–bone interface relative to experimental studies and can therefore be used to optimize its mechanical properties.  相似文献   

4.
In vivo, bone cement is subject to cyclic loading in a fluid environment. However, little is known about the effect of moisture absorption on the fatigue crack propagation resistance of bone cement. The effect of moisture absorption at 37 degrees C on the fatigue crack propagation resistance of a common bone cement (Endurance, DePuy, Orthopaedics, Inc.) was examined. Preliminary fracture toughness tests were conducted on disk-shaped, vacuum-mixed cement specimens (compact tension type) that were cyclically pre-cracked. Plain-strain fracture toughness K(IC) (MPa square root(m)) was determined. To study the effect of moisture absorption four treatment groups, with different soaking periods in Ringer's at 37 degrees C, of Endurance cement were tested. The specimens weights prior to and following soaking showed a significant increase in mean weight for specimens soaked for 8 and 12 weeks. Linear regression analysis of log(da/dN) vs. log (deltaK) was conducted on the combined data in each fatigue test group. Soaking bone cement in Ringer's at 37 degrees C for 8 and 12 weeks lead to an improvement in fatigue crack propagation resistance, that may be related to water sorption that increases polymer chain mobility, with enhanced crack tip blunting. It may be more physiologically relevant to conduct in vitro studies of fatigue and fracture toughness of bone cements following storage in a fluid environment.  相似文献   

5.
A clamped cantilever beam test was developed to determine the fatigue crack propagation rate of the CoCr alloy/PMMA cement interface at high crack tip phase angles. A combination of finite element and experimental methods was used to determine the fatigue crack growth rates of two different CoCr alloy/PMMA cement surfaces. A crack tip phase angle of 69 deg was found, indicating that loading at the crack tip was mixed-mode with a large degree of in-plane shear loading. The energy required to propagate a crack at the interface was much greater for the plasma-sprayed CoCr surface when compared to the PMMA-precoated satin finish (p < 0.001). Both interface surfaces could be modeled using a Paris fatigue crack growth law over crack propagation rates of 10(-4) to 10(-9) m/cycle.  相似文献   

6.
The cement–bone interface provides fixation for the cement mantle within the bone. The cement–bone interface is affected by fatigue loading in terms of fatigue damage or microcracks and creep, both mostly in the cement. This study investigates how fatigue damage and cement creep separately affect the mechanical response of the cement–bone interface at various load levels in terms of plastic displacement and crack formation. Two FEA models were created, which were based on micro-computed tomography data of two physical cement–bone interface specimens. These models were subjected to tensile fatigue loads with four different magnitudes. Three deformation modes of the cement were considered: ‘only creep’, ‘only damage’ or ‘creep and damage’. The interfacial plastic deformation, the crack reduction as a result of creep and the interfacial stresses in the bone were monitored. The results demonstrate that, although some models failed early, the majority of plastic displacement was caused by fatigue damage, rather than cement creep. However, cement creep does decrease the crack formation in the cement up to 20%. Finally, while cement creep hardly influences the stress levels in the bone, fatigue damage of the cement considerably increases the stress levels in the bone. We conclude that at low load levels the plastic displacement is mainly caused by creep. At moderate to high load levels, however, the plastic displacement is dominated by fatigue damage and is hardly affected by creep, although creep reduced the number of cracks in moderate to high load region.  相似文献   

7.
Patient-specific finite element models of the implanted proximal femur can be built from pre-operative computed tomography scans and post-operative X-rays. However, estimating three-dimensional positioning from two-dimensional radiographs introduces uncertainty in the implant position. Further, accurately measuring the thin cement mantle and the degree of cement–bone interdigitation from imaging data is challenging. To quantify the effect of these uncertainties in stem position and cement thickness, a sensitivity study was performed. A design-of-experiment study was implemented, simulating both gait and stair ascent. Cement mantle stresses and bone–implant interface strains were monitored. The results show that small variations in alignment affect the implant biomechanics, especially around the most proximal and most distal ends of the stem. The results suggest that implant position is more influential than cement thickness. Rotation around the medial–lateral axis is the dominant factor in the proximal zones and stem translations are the dominant factors around the distal tip.  相似文献   

8.
Stress shielding of the femur is known to be a principal factor in aseptic loosening of hip replacements. This paper considers the use of a hollow stemmed hip implant for reducing the effects of stress shielding, while maintaining acceptably low levels of stress in the cement. Using finite element modelling, the stresses in the proximal femur using different shapes of hollow stem were compared with those produced using comparable sizes of solid stem with different values of elastic modulus. A reduction in stress shielding could be achieved with a hollow stem. A cylindrical hollow stem design was then optimised in order to control the maximum allowable stress in the cement, the minimum allowable stresses in the bone, and a combination of the two. The resulting stems achieved an increase in proximal bone stress of about 15% for the first case and 32% for a model using high strength cement, compared with solid stems of the same nominal outside diameter. The gains of these theoretically optimised designs dropped off rapidly further down the stem. Linearly tapered hollow stems reached a 22% gain, which could be a good compromise between acceptable cement stresses and ease of manufacture.  相似文献   

9.
Knowledge of kinetics of fatigue crack growth of microcracks is important so as to understand the dynamics of bone adaptation, remodeling, and the etiology of fatigue-based failures of cortical bone tissue. In this respect, theoretical models (Taylor, J. Biomech., 31 (1998) 587-592; Taylor and Prendergast, Proc. Instn. Mech. Engrs. Part H 211 (1997) 369-375) of microcrack growth in cortical bone have predicted a decreasing microcrack growth rate with increasing microcrack length. However, these predictions have not been observed directly. This study investigated microcrack growth and arrest through observations of surface microcracks during cyclic loading (R=0.1, 50-80MPa) of human femoral cortical bone (male, n=4, age range: 37-40yr) utilizing a video microscopy system. The change in crack length and orientation of eight surface microcracks were measured with the number of fatigue cycles from four specimens. At the applied cyclic stresses, the microcracks propagated and arrested in generally less than 10,000 cycles. The fatigue crack growth rate of all microcracks decreased with increasing crack length following initial identification, consistent with theoretical predictions. The growth rate of the microcracks was observed to be in the range of 5x10(-5) to 5x10(-7)mmcycle(-1). In addition, many of the microcracks were observed not to grow beyond 150 microm and a cyclic stress intensity factor of 0.5MNm(-3/2). The results of this study suggest that cortical bone tissue may resist fracture at the microscale by deceleration of fatigue crack growth and arrest of microcracks.  相似文献   

10.
The "damage accumulation" phenomenon has not been quantitatively demonstrated in clinical cement mantles surrounding femoral hip stems. We stained transverse sections of 11 postmortem retrieved femoral hip components fixed with cement using fluorescent dye-penetrant and quantified cement damage, voids, and cement-bone interface gaps in epifluorescence and white light micrographs. Crack density (Cr.Dn), crack length-density (Cr.Ln.Dn), porosity, and cement-bone interface gap fraction (c/b-gap%) were calculated, normalized by mantle area. Multiple regression tests showed that cement damage (Cr.Ln.Dn. & Cr.Dn.) was significantly positively correlated (r(2)=0.98, p<0.001) with "duration of use" and body mass index ("BMI") but not cement mantle "porosity". There were significant interactions: "duration of use"*"BMI" was strongly predictive (p<0.005) of Cr.Dn.; and "duration of use"*"porosity" was predictive (p=0.04) of Cr.Ln.Dn. Stem related cracks accounted for approximately one fifth of Cr.Dn and one third of Cr.Ln.Dn. The mean c/b-gap% was 13.8% but it did not correlate (r(2)=0.01, p=0.8) with duration of use. We concluded that duration-dependent fatigue damage accumulation occurred during in vivo use. BMI strongly influenced cement crack length and the rate of new crack formation over time. Voids did not increase the rate of crack initiation but appeared to have promoted crack growth over time. Although not progressive, substantial bone resorption at the cement-bone interface appeared to be common.  相似文献   

11.
Optimal parameters for many orthopaedic implants, such as stem length and material, are unknown. Geometry and mechanical properties of bone can vary greatly amongst cadaveric specimens, requiring a large number of specimens to test design variations. This study aimed to develop an experimental methodology to measure bone strains as a function of multiple implant stem designs in a single specimen, and evaluate its efficacy in the distal ulna. Eight fresh-frozen cadaveric ulnae were each instrumented with 12 uniaxial strain gauges on the medial and lateral surfaces of the bone. The proximal portion of each ulna was cemented in a custom-designed jig that allowed a medially directed force to be applied to the distal articular surface. An implant with a finely threaded stem was cemented into the canal by an experienced upper extremity orthopaedic surgeon. Six loads (5-30 N) were applied sequentially to the lateral surface of the prosthetic head using a materials testing machine. Testing was repeated after breaking the stem-cement bond, and after removing and reinserting the stem several times into the threaded cement mantle. Near the end of the testing period, the initial stem was reinserted and data were collected to determine if there was any change in bone properties or testing setup over time. Finally, a smooth stem was inserted for comparison to the threaded stem. Strain varied linearly with load (R(2)> or =0.99) for all testing scenarios. Bending strains were not affected by breaking the stem-cement bond (P=0.7), testing durations up to 18 h (P=0.7), nor the presence of threads when compared to a smooth stem (P>0.4). Furthermore, for all gauges, there was no interaction between the effect of the threads and level of applied load (P>0.1). This methodology should prove to be useful to compare stem designs of varying lengths and materials in the same bone, allowing for a direct comparison between implant designs for the ulna and other bones subjected primarily to bending loads. Furthermore, it will minimize the need for large numbers of specimens to test multiple implant designs. The ultimate goal of using this protocol is to optimize implant stem properties, such as length and material, with respect to load transfer.  相似文献   

12.
Aseptic loosening of tibial components due to degradation of the interface between bone cement and metallic tibial shaft component is still a persistent problem, particularly for surface-cemented tibial components. The surface cementation technique has important clinical meaning in case of revision and for avoidance of stress shielding. This study was done to prove crack formation in the bone cement near the metallic surface when this is not coated. We propose a newly developed coating process by SiOx-PVD layering to avoid crack formation. A biomechanical model for a vibration fatigue test was done to prove that crack formation can be significantly reduced in the case of coated surfaces. It was found that coated tibial components showed a highly significant reduction of cement cracking near the metal/bone cement interface (p < 0.01) and a significant reduction of gap formation in the metal-to-bone cement interface (p < 0.05). Coating dramatically reduces hydrolytic- and stress-related crack formation at the prosthesis metal/bone cement interface. This leads to a more homogenous load transfer into the cement mantle which should reduce the frequency of loosening in the metal/bone cement/bone interfaces. With surface coating of the tibial component it should become possible that surface-cemented TKAs reveal similar loosening rates as TKAs both surface- and stem-cemented. This would be an important clinical advantage since it is believed that surface cementing reduces metaphyseal bone loss in the case of revision and stress shielding for a better bone health.  相似文献   

13.
Cemented stem constructs were loaded in cyclic fatigue using stair climbing loading and the resulting fatigue damage to the cement mantle was determined in terms of angular position of crack and crack length. Techniques from circular statistics were used to determine if the distribution of micro-cracks was uniform. With a designated orientation of 0 degrees -90 degrees -180 degrees -270 degrees indicating lateral-anterior-medial-posterior anatomic directions, the overall distribution of cracks was not uniform (p<0.05) with a mean crack direction in the postero-medial (249 degrees) quadrant of the mantle. The crack angular distribution for proximal (postero-medial; 251 degrees) and distal (antero-medial; 112 degrees) regions of the cement mantle was also different (p<0.025). These findings suggest that the location of cement damage depends on anatomic position and appears to correspond with the tensile stress field in the cement mantle.  相似文献   

14.
Premature fracture of the bone plate caused by fatigue crack is the main failure mode in treating femoral shaft fracture. In order to improve the durability of the plate, this study proposed a crack attraction hole (CAH) to retard the crack propagation based on the fracture mechanics. In this paper, a numerical model of the femoral fracture internal fixation system was constructed, in which the femur was developed using a validated simplified model. First, the fatigue crack initiation location was defined at the stress concentration through static analysis. Next, with the joint simulation method of Franc3D and ABAQUS, the fatigue crack path in the bone plate was predicted. Meanwhile, the Paris parameters of Ti-6Al-4V obtained through experiments were encoded into Franc3D to calculate the crack propagation life. Finally, we considered the influence of CAH designs with different relative vertical distances (2.0, 3.0, and 4.0 mm) and diameters (1.5, 2.0, and 2.5 mm) on the crack propagation path and life of the bone plate. Additionally, the effects of all CAH configurations on the biomechanical performance of the bone plate fixation system were evaluated. The results indicated that the fatigue crack growth path in the bone plate is comparable to a straight line, and the crack growth rate significantly increases when the crack tip reaches the outer boundary of the plate. The findings suggest that the addition of CAH in the bone plate will lead to the deflection of the crack path and increase the fatigue life. Equally important, the improvement of the fatigue life was positively correlated with the diameter of CAH and negatively correlated with the relative vertical distance. In addition, the biomechanical properties of the bone plate system were slightly affected by CAH, substantiating the feasibility of this method. Finally, the comparative analysis verified that a CAH with a relative vertical distance of 3 mm and a diameter of 2 mm exhibited superior improvement in the comprehensive performance on the bone plate.  相似文献   

15.
The effect of a short-stem femoral resurfacing component on load transfer and potential failure mechanisms has rarely been studied. The stem length has been reduced by approximately 50% as compared to the current long-stem design. Using 3-D FE models of natural and resurfaced femurs, the study is aimed at investigating the influence of a short-stem resurfacing component on load transfer and bone remodelling. Applied loading conditions include normal walking and stair climbing. The mechanical role of the stem along with implant–cement and stem–bone contact conditions was observed to be crucial. Shortening the stem length to half of the current length (long-stem) led to several favourable effects, even though the stress distributions in the implant and the cement were similar in both the cases. The short-stem implant led not only to a more physiological stress distribution but also to bone apposition (increase of 20–70% bone density) in the superior resurfaced head, when the stem–bone contact prevailed. This also led to a reduction in strain concentration in the cancellous bone around the femoral neck–component junction. The normalised peak strain in this region was lower for the short-stem design as compared to that of the long-stem one, thereby reducing the initial risk of neck fracture. The effect of strain shielding (50–75% reduction) was restricted to a small bone volume underlying the cement, which was approximately half of that of the long-stem design. Consequently, bone resorption was considerably less for the short-stem design. The short-stem design offers better prospects than the long-stem resurfacing component.  相似文献   

16.
One possible loosening mechanism of the femoral component in total hip replacement is fatigue cracking of the cement mantle. A computational method capable of simulating this process may therefore be a useful tool in the preclinical evaluation of prospective implants. In this study, we investigated the ability of a computational method to predict fatigue cracking in experimental models of the implanted femur construct. Experimental specimens were fabricated such that cement mantle visualisation was possible throughout the test. Two different implant surface finishes were considered: grit blasted and polished. Loading was applied to represent level gait for two million cycles. Computational (finite element) models were generated to the same geometry as the experimental specimens, with residual stress and porosity simulated in the cement mantle. Cement fatigue and creep were modelled over a simulated two million cycles. For the polished stem surface finish, the predicted fracture locations in the finite element models closely matched those on the experimental specimens, and the recorded stem displacements were also comparable. For the grit blasted stem surface finish, no cement mantle fractures were predicted by the computational method, which was again in agreement with the experimental results. It was concluded that the computational method was capable of predicting cement mantle fracture and subsequent stem displacement for the structure considered.  相似文献   

17.
A mechanistic understanding of the role of bone quality on fracture processes is essential for determining the underlying causes of age-related changes in the mechanical response of the human bone. In this study, a previously developed cohesive finite element model was used to investigate the effects of age-related changes and the orientation of crack growth on the toughening behavior of human cortical bone. The change in the anisotropy of toughening mechanisms with age was also studied. Finite element method (FEM) simulations showed that the initiation toughness decreased by 3% and 8%/decade for transverse and longitudinal crack growth, respectively. In contrast, fracture resistance curve slope for transverse and longitudinal crack growth decreased by 2% and 3%/decade, respectively. Initiation fracture toughness values were higher for the transverse than for the longitudinal for a given age. On the other hand, propagation fracture toughness values were higher for longitudinal than for transverse crack growth for a given age. With respect to age, the toughness ratio for crack initiation decreased by 6%/decade, but that for propagation showed almost no change (less than 1%). In light of these findings, an analytical model evaluating the crack arresting feature of cement lines, is proposed to explain the factors that determine crack penetration into osteons or its deflection by cement lines.  相似文献   

18.
Fatigue cracking in the cement mantle of total hip replacement has been identified as a possible cause of implant loosening. Retrieval studies and in vitro tests have found porosity in the cement may facilitate fatigue cracking of the mantle. The fatigue process has been simulated computationally using a finite element/continuum damage mechanics (FE/CDM) method and used as a preclinical testing tool, but has not considered the effects of porosity. In this study, experimental tensile and four-point bend fatigue tests were performed. The tensile fatigue S-N data were used to drive the computational simulation (FE/CDM) of fatigue in finite element models of the tensile and four-point bend specimens. Porosity was simulated in the finite element models according to the theory of elasticity and using Monte Carlo methods. The computational fatigue simulations generated variability in the fatigue life at any given stress level, due to each model having a unique porosity distribution. The fracture site also varied between specimens. Experimental validation was achieved for four-point bend loading, but only when porosity was included. This demonstrates that the computational simulation of fatigue, driven by uniaxial S-N data can be used to simulate nonuniaxial loadcases. Further simulations of bone cement fatigue should include porosity to better represent the realities of experimental models.  相似文献   

19.
An investigation was performed to determine the effects of the presence of two lengths of proximal Müller prosthesis on predicted failure loads, as compared to those for an intact femur. Three-dimensional stresses in a bone/cement/prosthesis system were determined using finite element methods, with both isotropic and transversely isotropic material properties used for the diaphyseal cortex. Significant increases in prosthesis stem stresses were found when the transversely isotropic material properties were employed in the diaphyseal cortex. This leads to the conclusion that accurate anisotropic material properties for bone are essential for precise stress determination and optimum design in prosthetic implants. Failure loads were also predicted for vertical compression and axial torque, similar to available experimental conditions, and were within the range of the experimental failure data found in the literature. The technique developed herein can be used to systematically assess existing as well as future implant designs, taking into account the complex three-dimensional interaction effects of the overall bone/cement/prosthesis system.  相似文献   

20.
Acrylic bone cements are widely used for fixation of joint prostheses as well as for vertebral body augmentation procedures of vertebroplasty and balloon kyphoplasty, with the cement zone(s) being subjected to repeated mechanical loading in each of these applications. Although, in vertebroplasty and balloon kyphoplasty, the cement zone is exposed to mainly cyclical compressive load, the compressive fatigue properties of acrylic bone cements used in these procedures are yet to be determined. The purposes of the present study were to determine the compressive fatigue properties of a commercially available cement brand used in vertebroplasty, including the effect of frequency on these properties; to identify the cement failure modes under compressive cyclical load; and to introduce a screening method that may be used to shorten the lengthy character of the standardized fatigue tests. Osteopal \({^\circledR } \mathrm{V}\) was used as the model cement in this study. The combinations of maximum stress and frequency used were 50.0, 55.0, 60.0, 62.5 and 75.5 MPa at 2 Hz; and of 40.0, 55.0, 60.0, 62.5 or 75.5 MPa at 10 Hz. Through analysis of nominal strain-number of loading cycles results, three cement failure modes were identified. The estimated mean fatigue limit at 2 Hz (55.4 MPa) was significantly higher than that at 10 Hz (41.1 MPa). The estimated fatigue limit at 2 Hz is much higher than stresses commonly found in the spine and also higher than that for other acrylic bone cements tested in a full tension–compression fatigue test, which indicates that tension–compression fatigue testing may substantially underestimate the performance of cements intended for vertebroplasty. A screening method was introduced which may be used to shorten the time spent in performing compressive fatigue tests on specimens of acrylic bone cement for use in vertebral body augmentation procedures.  相似文献   