首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An antibody-direct epifluorescent filter technique (Ab-DEFT) detected 100% of the raw ground beef samples inoculated with Escherichia coli O157 : H7 cells (0·15 cells g−1) and incubated in a prewarmed, modified buffered peptone water (mBPW) non-selective enrichment broth for 5 h at 42°C in an orbital shaking water bath (200 rev min−1). Over 50% of the microscopic fields viewed were positive (1–10 fluorescent cells field−1) in the Ab-DEFT. All positive screening results were confirmed within 24 h by subjecting 1 ml of the mBPW to the Dynabeads® anti- E. coli O157 immunomagnetic separation procedure, followed by plating on MacConkey sorbitol agar containing 5-bromo-4-chloro-3-indolyl-β- D -glucuronide. At this cell concentration, 41·7% of the inoculated samples were detected by the conventional method involving a 24-h selective enrichment. Exposure to viable cells before filtration was minimized by using a 0·58% formaldehyde concentration for 5 min at 50°C (killed >4·00 logs of E. coli O157 : H7 cells) without affecting cell fluorescence.  相似文献   

2.
In this study, the sensitivities of multiplex PCR and an immuno-chromatographic methods to detect Escherichia coli O157:H7 in minced beef were compared. The detection of Escherichia coli O157:H7 in minced beef inoculated with 1-100 cells of this bacterium was possible after enrichment of culture and subsequent analysis by either of the two methods. Enrichment conditions were eight hours of incubation at 37 degrees C or 42 degrees C in a non-selective medium (Buffered Peptone Water). Multiplex PCR analysis was performed using three primer sets with analysis by gel electrophoresis. The Quix immuno-chromatographic assay which is a new kit being marketed by New Horizons Diagnostics, Columbia, MD, was used for immunological analysis of the enriched broths.The sensitivity of both tests was similar. The results depended on the concentration of the specific bacterium in the culture since the influence of the proportion of other bacteria to the E. coli O157:H7 was not observed. The data suggests that either method or used together, when coupled with an enrichment technique, could provide a rapid mean to detect the presence of this pathogen in minced meat samples.  相似文献   

3.
In this study, enrichment procedures and two recovery methods, a membrane surface adhesion technique and an immunomagnetic separation (IMS), were compared for use in conjunction with a multiplex polymerase chain reaction (PCR) method with a view to describing a fast (24 h) and economical test for detection of Escherichia coli O157:H7 in meat samples. The study showed no significant difference between three different enrichment media (BHI, E. coli (E.C.) broth+novobiocin, modified tryptone soya broth (mTSB)+novobiocin) or two incubation temperatures (37 or 41.5 degrees C) for growth of E. coli O157:H7 in minced beef. Minced beef samples inoculated with E. coli O157:H7 at 40 cfu g(-1) were incubated at 37 degrees C for 16 h in E.C. broth+novobiocin reaching numbers of (log(10)7.82-8.70). E. coli O157:H7 were recovered by attachment to polycarbonate membranes immersed in the enriched cultures for 15 min or by immunomagnetic separation. Subsequent treatment of recovered membranes or IMS beads with lysis buffer and phenol/chloroform/isoamyl alcohol was used to extract the DNA from the extracted E. coli O157:H7 cells. The results show when E. coli O157:H7 was present at high levels in the enriched meat sample (log(10)9.6-7.5 cfu ml(-1); >16-h enrichment), the membrane and IMS techniques recovered similar levels of the pathogen and the microorganism was detectable by PCR using both methods. At lower levels of E. coli O157:H7 (log(10)6.4), only the IMS method could recover the pathogen but at levels below this neither method could recover sufficient numbers of the pathogens to allow detection. The conclusion of the study is that with sufficient enrichment time (16 h) the membrane surface adhesion membrane extraction method used in combination with multiplex PCR has the potential for a rapid and economical detection method.  相似文献   

4.
AIMS: To assess the detection and recovery rates achieved with commonly used cultural methods for the enumeration and recovery of Escherichia coli O157:H7 from minced beef and bovine hide. METHODS AND RESULTS: Minced beef and bovine hide were inoculated with varying concentrations (log(10) 1.58-2.58 CFU g(-1) and log(10) 2.42-4.49 CFU 100 cm(2) respectively) of E. coli O157:H7 and recovered using a direct plate method or an enrichment/immunomagnetic separation (IMS) method and then plated onto SMAC or SMAC-CT in both cases. The direct plate method detected the pathogen consistently from minced beef samples with an average recovery of 69.2-91.2%. From faecal material on the bovine hide the recovery of the pathogen ranged from 1.80 to 64.5% with fresh faeces depending on the inocula while from dried faeces on hide the results ranged from no recovery at all to 25.1%. Enrichment/IMS recovered E. coli O157:H7 at all inocula levels tested in minced beef while the pathogen was only detected consistently at an average inocula level of log(10) 2.73 CFU 100 cm(2) from fresh faeces and log(10) 4.49 CFU 100 cm(2) from dried faeces on bovine hide. CONCLUSIONS: The direct count enumeration method for E. coli O157:H7 underestimated the numbers of pathogens present. The enrichment/IMS procedure consistently detected the pathogen from minced beef but did not always detect E. coli O157:H7 from faeces on bovine hide. SIGNIFICANCE AND IMPACT OF THE STUDY: Overall this study highlights that any microbial data, used in either predictive microbiology or risk assessment, must take account of the sensitivity and associated performance of the methods employed, in order to make an accurate reflection of the true microbiology of the examined sample.  相似文献   

5.
A total of 896 samples of retail fresh meats and poultry was assayed for Escherichia coli serogroup O157:H7 by a hydrophobic grid membrane filter-immunoblot procedure developed specifically to isolate the organism from foods. The procedure involves several steps, including selective enrichment, filtration of enrichment culture through hydrophobic grid membrane filters, incubation of each filter on nitrocellulose paper on selective agar, preparation of an immunoblot (by using antiserum to E. coli O157:H7 culture filtrate) of each nitrocellulose paper, selection from the filters of colonies which corresponded to immunopositive sites on blots, screening of isolates by a Biken test for precipitin lines from metabolites and antiserum to E. coli O157:H7 culture filtrate, and confirmation of isolates as Vero cell cytotoxic E. coli O157:H7 by biochemical, serological, and Vero cell cytotoxicity tests. E. coli O157:H7 was isolated from 6 (3.7%) of 164 beef, 4 (1.5%) of 264 pork, 4 (1.5%) of 263 poultry, and 4 (2.0%) of 205 lamb samples. One of 14 pork samples and 5 of 17 beef samples contaminated with the organism were from Calgary, Alberta, Canada, grocery stores, whereas all other contaminated samples were from Madison, Wis., retail outlets. This is the first report of the isolation of E. coli O157:H7 from food other than ground beef, and results indicate that the organism is not a rare contaminant of fresh meats and poultry.  相似文献   

6.
AIMS: Escherichia coli O157:H7 was monitored daily during sprouting of alfalfa seeds inoculated at high (3.92 log10 cfu g(-1)) and low (1.86 log10 cfu g(-1)) levels to assess the extent of pathogen growth during production. METHODS AND RESULTS: Sprouts and rinse water were tested by direct and membrane filter plating on modified sorbitol MacConkey agar and BCM O157:H7(+) agar; the antibody-direct epifluorescent filter technique; and rapid immunoassays. The pathogen reached maximum populations after one and two days of sprouting seeds inoculated at high and low levels, respectively; in either case, populations of 5-6 log10 cfu g(-1) were reached. Detection limits of two rapid immunoassays, Reveal and VIP, without enrichment were determined to be 5-7 log10 cfu ml(-1). CONCLUSION: These results show the ability of E. coli O157:H7 to grow to high levels during sprouting; however, because these levels may be below detection limits, it is necessary to include enrichment when monitoring sprout production for E. coli O157:H7 by the rapid test kits. SIGNIFICANCE AND IMPACT OF THE STUDY: The data indicate that sprouts may harbor high levels of pathogens. The appropriate use of rapid test methods for pathogen monitoring during sprouting is indicated.  相似文献   

7.
AIMS: To determine the prevalence of four bacterial zoonotic pathogens in beef cattle at time of slaughter in Northern Ireland (NI), in order to assess their potential for reducing beef safety. METHODS AND RESULTS: Faeces were collected postmortem from beef cattle (n =220) at seven EU registered abattoirs. Standard enrichment culturing methods were employed, plus immunomagnetic enrichment in the case of Escherichia coli O157:H7. Campylobacter spp. were found in 52 samples (24.8%), Listeria monocytogenes in 10 (4.8%), E. coli O157:H7 in 2 (0.9%) whilst Salmonella spp. were isolated from six out of 200 samples (3.0%). Five salmonellas were Salmonella Chandans and one was Salmonella Liverpool. CONCLUSIONS: Campylobacter spp. were the most frequently isolated pathogen, despite being relatively rare in beef. Genotyping showed the campylobacters to be very diverse, indicating cattle encounter campylobacters from many sources. The remaining three pathogens, which are associated with meats, occurred at relatively low frequencies, especially E. coli O157:H7. The Salmonella serovars found rarely infect humans. SIGNIFICANCE AND IMPACT OF THE STUDY: The low prevalence of E. coli O157:H7 in NI beef cattle was confirmed and the reasons for this merit further study. The four pathogens should have little impact on beef quality.  相似文献   

8.
The simultaneous growth of Escherichia coli O157:H7 (O157) and the ground beef background microflora (BM) was described in order to characterize the effects of enrichment factors on the growth of these organisms. The different enrichment factors studied were basal medium (Trypticase soy broth and E. coli broth), the presence of novobiocin in the broth, and the incubation temperature (37 degrees C or 40 degrees C). BM and O157 kinetics were simultaneously fitted by using a competitive growth model. The simple competition between the two microfloras implied that O157 growth stopped as soon as the maximal bacterial density in the BM was reached. The present study shows that the enrichment protocol factors had little impact on the simultaneous growth of BM and O157. The selective factors (i.e., bile salts and novobiocin) and the higher incubation temperature (40 degrees C) did not inhibit BM growth, and incubation at 40 degrees C only slightly improved O157 growth. The results also emphasize that when the level of O157 contamination in ground beef is low, the 6-h enrichment step recommended in the immunomagnetic separation protocol (ISO EN 16654) is not sufficient to detect O157 by screening methods. In this case, prior enrichment for approximately 10 h appears to be the optimal duration for enrichment. However, more experiments must be carried out with ground beef packaged in different ways in order to confirm the results obtained in the present study for non-vacuum- and non-modified-atmosphere-packed ground beef.  相似文献   

9.
Detection of Escherichia coli O157:H7 organisms in food, clinical or environmental samples is necessary for diagnosis of infection and epidemiological investigations. However, this pathogen may be present in low numbers and difficult to identify among high numbers of other background bacteria. In order to increase the sensitivity of culture- and PCR detection, pre-enrichment of E. coli O157:H7 in broth culture combined with ImmunoMagnetic cell Separation (IMS) is routinely employed. These methods, although able to detect levels as low as 2 cfu/g (from 10 to 25 g samples), are qualitative detection strategies only. If the actual numbers of E. coli O157:H7 are to be quantified, growth enrichment must be excluded and the organisms isolated directly from the sample of interest. Such quantification is necessary, for example, to determinate contamination levels on beef carcasses and for determination of bacterial numbers in in vivo gene expression studies. In the present study, it was not possible to recover organisms from bovine faecal suspensions using the customary IMS system and so a range of alternative buffers and other paramagnetic beads was tested. Combination of a 6.2-microm diameter bead with a detergent-based buffer gave optimal recovery of E. coli O157:H7 organisms from faecal suspensions. This system was validated for recovery of E. coli O157:H7 by comparing it with that obtained with the standard Dynabeads IMS protocol, using both the traditional broth enrichment method and a quantitative detection approach. We conclude that a 6.2-microm diameter Aureon bead can be used for quantitative isolation of E. coli O157:H7 directly from bovine faeces and, for this purpose, is preferred to the 2.8-microm diameter Dynal bead.  相似文献   

10.
The simultaneous growth of Escherichia coli O157:H7 (O157) and the ground beef background microflora (BM) was described in order to characterize the effects of enrichment factors on the growth of these organisms. The different enrichment factors studied were basal medium (Trypticase soy broth and E. coli broth), the presence of novobiocin in the broth, and the incubation temperature (37°C or 40°C). BM and O157 kinetics were simultaneously fitted by using a competitive growth model. The simple competition between the two microfloras implied that O157 growth stopped as soon as the maximal bacterial density in the BM was reached. The present study shows that the enrichment protocol factors had little impact on the simultaneous growth of BM and O157. The selective factors (i.e., bile salts and novobiocin) and the higher incubation temperature (40°C) did not inhibit BM growth, and incubation at 40°C only slightly improved O157 growth. The results also emphasize that when the level of O157 contamination in ground beef is low, the 6-h enrichment step recommended in the immunomagnetic separation protocol (ISO EN 16654) is not sufficient to detect O157 by screening methods. In this case, prior enrichment for approximately 10 h appears to be the optimal duration for enrichment. However, more experiments must be carried out with ground beef packaged in different ways in order to confirm the results obtained in the present study for non-vacuum- and non-modified-atmosphere-packed ground beef.  相似文献   

11.
Escherichia coli O157:H7, a major foodborne pathogen, has been associated with numerous cases of foodborne illnesses. Rapid methods have been developed for the screening of this pathogen in foods in order to circumvent timely plate culture techniques. Unfortunately, many rapid methods are presumptive and do not claim to confirm the presence of E. coli O157:H7. The previously developed method, enzyme-linked immunomagnetic chemiluminescence (ELIMCL), has been improved upon to allow for fewer incidences of false positives when used to detect E. coli O157:H7 in the presence of mixed cultures. The key feature of this assay is that it combines the highly selective synergism of both anti-O157 and anti-H7 antibodies in the sandwich immunoassay format. This work presents application of a newly semi-automated version of ELIMCL to the detection of E. coli O157:H7 in pristine buffered saline yielding detection limits of approximately 1 x 10(5) to 1 x 10(6) of live cells/mL. ELIMCL was further demonstrated to detect E. coli O157:H7 inoculated into artificially contaminated ground beef at ca. 400 CFU/g after a 5 h enrichment and about 1.5 h assay time for a total detection time of about 6.5 h. Finally, ELIMCL was compared with USFDA's Bacteriological Analytical Manual method for E. coli O157:H7 in a double-blind study. Using McNemar's treatment, the two methods were determined to be statistically similar for the detection of E. coli O157:H7 in ground beef inoculated with mixed cultures of select bacteria.  相似文献   

12.
A sensitive, specific procedure was developed for detecting Escherichia coli O157:H7 in food in less than 20 h. The procedure involves enrichment of 25 g of food in 225 ml of a selective enrichment medium for 16 to 18 h at 37 degrees C with agitation (150 rpm). The enrichment culture is applied to a sandwich enzyme-linked immunosorbent assay (ELISA) with a polyclonal antibody specific for E. coli O157 antigen as the capture antibody and a monoclonal antibody specific for enterohemorrhagic E. coli of serotypes O157:H7 and O26:H11 as the detection antibody. The ELISA can be completed within 3 h. The sensitivity of the procedure, determined by using E. coli O157:H7-inoculated ground beef and dairy products, including different varieties of cheese, was 0.2 to 0.9 cell per g of food. A survey of retail fresh ground beef and farm raw milk samples with this procedure revealed that 3 (2.8%) of 107 ground beef samples and 11 (10%) of 115 raw milk samples were positive for E. coli O157:H7. Most-probable-number determinations revealed E. coli O157:H7 populations of 0.4 to 1.5 cells per g in the three ground beef samples. In addition to being highly specific, sensitive, and rapid, this procedure is easy to perform and is amenable to use by laboratories performing routine microbiological testing.  相似文献   

13.
A sensitive, specific procedure was developed for detecting Escherichia coli O157:H7 in food in less than 20 h. The procedure involves enrichment of 25 g of food in 225 ml of a selective enrichment medium for 16 to 18 h at 37 degrees C with agitation (150 rpm). The enrichment culture is applied to a sandwich enzyme-linked immunosorbent assay (ELISA) with a polyclonal antibody specific for E. coli O157 antigen as the capture antibody and a monoclonal antibody specific for enterohemorrhagic E. coli of serotypes O157:H7 and O26:H11 as the detection antibody. The ELISA can be completed within 3 h. The sensitivity of the procedure, determined by using E. coli O157:H7-inoculated ground beef and dairy products, including different varieties of cheese, was 0.2 to 0.9 cell per g of food. A survey of retail fresh ground beef and farm raw milk samples with this procedure revealed that 3 (2.8%) of 107 ground beef samples and 11 (10%) of 115 raw milk samples were positive for E. coli O157:H7. Most-probable-number determinations revealed E. coli O157:H7 populations of 0.4 to 1.5 cells per g in the three ground beef samples. In addition to being highly specific, sensitive, and rapid, this procedure is easy to perform and is amenable to use by laboratories performing routine microbiological testing.  相似文献   

14.
AIM: To develop an improved, rapid and sensitive sample preparation method for PCR-based detection of Escherichia coli O157:H7 in ground beef. METHODS AND RESULTS: Fresh ground beef samples were experimentally inoculated with varying concentrations of E. coli O157:H7. PCR inhibitors were removed and bacterial cells were concentrated by filtration and centrifugation, and lysed using enzymatic digestion and successive freeze/thaw cycles. DNA was purified and concentrated via phenol/chloroform extraction and the Shiga toxin 1 gene (stx1) was amplified using PCR to evaluate the sample preparation method. Without prior enrichment of cells in broth media, the detection limit was 103 CFU g-1 beef. When a 6 h enrichment step was incorporated, the detection limit was 1 CFU g-1 beef. The total time required from beginning to end of the procedure was 12 h. CONCLUSIONS: The sample preparation method developed here enabled substantially improved sensitivity in the PCR-based detection of E. coli O157:H7 in ground beef, as compared to previous reports. SIGNIFICANCE AND IMPACT OF THE STUDY: Superb sensitivity, coupled with quick turn-around time, relative ease of use and cost-effectiveness, makes this a useful method for detecting E. coli O157:H7 in ground beef.  相似文献   

15.
There was no significant difference (P > 0.05) in the percentages of Escherichia coli O157:H7 cells recovered on BCM O157:H7 (+) agar (69.7%) and MacConkey sorbitol agar containing 5-bromo-4-chloro-3-indoxyl-beta-D-glucuronic acid (MSA-BCIG) (76.8%) vs Tryptic soy agar. Three E. coli O157:H7 strains (ATCC 35150, 43890 and 43894) were separately inoculated into raw ground beef at low (mean 0.32 cfu g-1) and high (mean 3.12 cfu g-1) levels. Using the United States Department of Agriculture (USDA) m-EC + novobiocin enrichment broth, BCM O157:H7 (+) medium surpassed MSA-BCIG agar with overall percentage sensitivities for BCM O157:H7 (+) of 92.1 and 94.4 compared with 52.6 and 84.7 for MSA-BCIG at low and high levels, respectively. A comparison of BCM O157:H7 (+) and MSA-BCIG agars using naturally contaminated beef samples was made utilizing presumptively positive enrichment broths previously identified by rapid methods. The E. coli O157:H7 cells in these broths were concentrated with Dynabeads anti-E. coli O157 before inoculating the agars. The respective percentage sensitivity and specificity values were 90.0 and 78.5 for BCM O157:H7 (+) and 70.0 and 46.4 for MSA-BCIG. Thus, under identical pre-plating conditions, BCM O157:H7 (+) medium displayed a greater sensitivity than MSA-BCIG for detecting E. coli O157:H7 in artificially inoculated beef, and both greater sensitivity and specificity upon examining naturally contaminated beef samples.  相似文献   

16.
The purpose of this study was to apply our rapid, integrated double enrichment 5' nuclease real-time polymerase chain reaction assay for the detection of Escherichia coli O157:H7 and evaluate its efficacy. The assay targeted ground beef, an important vehicle in disease epidemiology. The assay reliably determined in 8 h the presence of E. coli O157:H7 in ground beef at the level of 1 colony-forming unit (CFU)/g. The sensitivity and specificity of the assay were compared with that of standard enrichment diagnostic techniques. A correlation of 100% in detection was achieved to the limit of 1 CFU/g. This assay can be used as a rapid, automatic process for identification of E. coli O157:H7 in ground beef or can be integrated with standard culture procedures, resulting in considerable cost and time savings.  相似文献   

17.
AIM: To estimate the distribution and prevalence of both Escherichia coli O157 and O157:H7-infecting bacteriophages within a 50,000 head commercial beef feedlot. METHODS AND RESULTS: Escherichia coli O157 was detected in approximately 27% of the individual samples, distributed across seven of the 10 pens screened. In a simple initial screen to detect O157:H7-infecting phages, none were detected in any pen or individual sample. In contrast, after a series of enrichment procedures O157:H7-infecting phages were detected in every pen and in the majority of the samples from most pens; virulent bacteriophages active against E. coli O157:H7 were detected post-enrichment from 39/60 (65%) of the feedlot samples, and 58/60 (approximately 97%) contained phage that infected E. coli B or O157:H7. CONCLUSIONS: The data we present here indicates that we may be grossly underestimating the prevalence of O157:H7-infecting phages in livestock if we simply screen samples and that enrichment screening is required to truly determine the presence of phages in these ecosystems. SIGNIFICANCE AND IMPACT OF THE STUDY: Our data suggest that O157:H7-infecting phages may play a role in the ecology and transient colonization of cattle by E. coli O157:H7. Further, this and previous data suggest that before starting in vivo pathogen eradication studies using phage or any other regime, test animals should be enrichment screened for phage to avoid erroneous results.  相似文献   

18.
We found effective enrichment procedures for detecting Escherichia coli O26 in foods using methods that are used for E. coli O157. Ground beef or radish sprouts inoculated with approximately 6 colony-forming units of E. coli O26 were homogenized in 225 ml of various broths. After static incubation at 37 degrees C or 42 degrees C for 6 h or 18 h, we isolated the inoculated bacterium by plating onto Rainbow Agar O157 with novobiocin. In combination with the immunomagnetic separation method, E. coli O26 was isolated from all samples by using enrichment in tryptone soy broth at 37 degrees C for 6 h and in modified E. coli broth with novobiocin (mEC + n) at 42 degrees C for 18 h in ground beef and radish sprouts, respectively. Enrichment in mEC + n at 42 degrees C for 18 h was effective for isolating both E. coli O26 and E. coli O157 from both ground beef and radish sprouts.  相似文献   

19.
Aims: We compared the efficiency of universal pre‐enrichment broth (UPB), modified Escherichia coli broth containing novobiocin (mEC + n), modified Tryptic Soy Broth (mTSB) and mTSB with novobiocin (mTSB + n) for the enrichment of non‐O157 Shiga‐toxin‐producing E. coli (STEC). Methods and Results: Freeze‐injured and control non‐O157 STEC (O91, O103, O111, O119, O121, O145 and O165) strains were used to artificially contaminate beef and radish sprout samples, which were then cultivated in each of the four enrichment media. After incubation, STEC strains were detected by loop‐mediated isothermal amplification (LAMP) and plating assays. Enrichment in mEC + n was least effective for facilitating the detection of uninjured STEC strains in radish sprouts, while mTSB + n was least effective for enriching freeze‐injured non‐O157 STEC strains from beef samples for detection by LAMP assay. UPB and mTSB were superior to mEC + n and mTSB + n for the enrichment of non‐O157 STEC from food samples. Conclusions: The enrichment of non‐O157 STEC was negatively affected by the addition of novobiocin to enrichment broths. Significance and Impact of the study: Novobiocin should not be added to media used for the enrichment of non‐O157 STEC in food when cell injury is anticipated.  相似文献   

20.
A sensitive and easy-to-perform dipstick immunoassay to detect Escherichia coli O157:H7 in retail ground beef was developed by using a sandwich-type assay (with a polyclonal antibody to E. coli O157 as the capture antibody and a monoclonal antibody to E. coli O157:H7 as the detection antibody) on a hydrophobic polyvinylidine difluoride-based membrane. E. coli O157:H7 in ground beef could be detected within 16 h, including incubation for 12 h in enrichment broth and the immunoassay, which takes 4 h. Pure culture cell suspensions of 10(5) or 10(6) E. coli O157:H7 organisms per ml produced intense color reactions in the immunoassay, whereas faint but detectable reactions occurred with 10(3) CFU/ml. The sensitivity of the combined enrichment-immunoassay procedure as determined by using ground beef inoculated with E. coli O157:H7 was 0.1 to 1.3 cells per g, with a false-positive rate of 2.0%. A survey of retail ground beef using this procedure revealed that 1 of 76 samples was contaminated by E. coli O157:H7.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号