首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
Troszak GD  Rubinsky B 《PloS one》2011,6(4):e18523
Electroporation, the permeabilization of the cell membrane lipid bilayer due to a pulsed electric field, has important implications in the biotechnology, medicine, and food industries. Traditional macro and micro-electroporation devices have facing electrodes, and require significant potential differences to induce electroporation. The goal of this theoretical study is to investigate the feasibility of singularity-induced micro-electroporation; an electroporation configuration aimed at minimizing the potential differences required to induce electroporation by separating adjacent electrodes with a nanometer-scale insulator. In particular, this study aims to understand the effect of (1) insulator thickness and (2) electrode kinetics on electric field distributions in the singularity-induced micro-electroporation configuration. A non-dimensional primary current distribution model of the micro-electroporation channel shows that while increasing insulator thickness results in smaller electric field magnitudes, electroporation can still be performed with insulators thick enough to be made with microfabrication techniques. Furthermore, a secondary current distribution model of the singularity-induced micro-electroporation configuration with inert platinum electrodes and water electrolyte indicates that electrode kinetics do not inhibit charge transfer to the extent that prohibitively large potential differences are required to perform electroporation. These results indicate that singularity-induced micro-electroporation could be used to develop an electroporation system that consumes minimal power, making it suitable for remote applications such as the sterilization of water and other liquids.  相似文献   

2.
The charging of the plasmalemma is a necessary condition for permeabilization of the plasma membrane (electroporation) in response to external electric field exposure. Common theories explain this permeabilization by formation of pores in the lipid bilayer. Using pulsed laser fluorescence microscopy, we measured the charging process of the membrane during the application of an external electric field with a temporal resolution of 5 ns. Visualization of the charging process of protoplasts plasma membrane (Nicotiana tabacum Bright Yellow 2) was achieved by staining of the plasma membrane with the voltage-sensitive fluorescent dye ANNINE-6. Measurements on membranes exhibiting negligible membrane permeabilization confirm the sine-shaped azimuthal distribution of the membrane voltage predicted by the relation of Cole. At higher membrane voltages, enhanced pore formation allows for the exchange of charge carriers, leading to deviations from the sine-shaped curve progression, i.e., a saturation of the membrane voltage at membrane segments facing the electrodes. Additionally, measurements on protoplasts exposed to multiple successive pulses indicate that the recovery of the membrane seems to be a fast process, occurring within seconds after termination of the external electric field pulse.  相似文献   

3.
Geng T  Zhan Y  Wang J  Lu C 《Nature protocols》2011,6(8):1192-1208
Electroporation is a high-efficiency and low-toxicity physical gene transfer method. Classical electroporation protocols are limited by the small volume of cell samples processed (less than 10(7) cells per reaction) and low DNA uptake due to partial permeabilization of the cell membrane. Here we describe a flow-through electroporation protocol for continuous transfection of cells, using disposable devices, a syringe pump and a low-cost power supply that provides a constant voltage. We show transfection of cell samples with rates ranging from 40 μl min(-1) to 20 ml min(-1) with high efficiency. By inducing complex migrations of cells during the flow, we also show permeabilization of the entire cell membrane and markedly increased DNA uptake. The fabrication of the devices takes 1 d and the flow-through electroporation typically takes 1-2 h.  相似文献   

4.
The change in the membrane potential of Jurkat cells in response to nanosecond pulsed electric fields was studied for pulses with a duration of 60 ns and maximum field strengths of approximately 100 kV/cm (100 V/cell diameter). Membranes of Jurkat cells were stained with a fast voltage-sensitive dye, ANNINE-6, which has a subnanosecond voltage response time. A temporal resolution of 5 ns was achieved by the excitation of this dye with a tunable laser pulse. The laser pulse was synchronized with the applied electric field to record images at times before, during, and after exposure. When exposing the Jurkat cells to a pulse, the voltage across the membrane at the anodic pole of the cell reached values of 1.6 V after 15 ns, almost twice the voltage level generally required for electroporation. Voltages across the membrane on the side facing the cathode reached values of only 0.6 V in the same time period, indicating a strong asymmetry in conduction mechanisms in the membranes of the two opposite cell hemispheres. This small voltage drop of 0.6-1.6 V across the plasma membrane demonstrates that nearly the entire imposed electric field of 10 V/mum penetrates into the interior of the cell and every organelle.  相似文献   

5.
In vivo electroporation is increasingly being used to deliver small molecules as well as DNA to tissues. The aim of this study was to quantitatively investigate in vivo electroporation of skeletal muscle, and to determine the threshold for permeabilization. We designed a quantitative method to study in vivo electroporation, by measuring uptake of (51)Cr-EDTA. As electrode configuration influences electric field (E-field) distribution, we developed a method to calculate this. Electroporation of mouse muscle tissue was investigated using either external plate electrodes or internal needle electrodes placed 4 mm apart, and eight pulses of 99 micros duration at a frequency of 1 Hz. The applied voltage to electrode distance ratio was varied from 0 to 2.0 kV/cm. We found that: (1) the threshold for permeabilization of skeletal muscle tissue using short duration pulses was at an applied voltage to electrode distance ratio of 0.53 kV/cm (+/-0.03 kV/cm), corresponding to an E-field of 0.45 kV/cm; (2) there were two phases in the uptake of (51)Cr-EDTA, the first indicating increasing permeabilization and the second indicating beginning irreversible membrane damage; and (3) the calculated E-field distribution was more homogeneous for plate than for needle electrodes, which was reflected in the experimental results.  相似文献   

6.
A tetraphenylphosphonium ion (TPP(+))-selective electrode, originally developed as a membrane potential indicator, is useful for measuring increases in the permeability of bacterial outer membranes induced by antimicrobial agents. The combination of this electrode with a potassium ion-selective electrode enabled us to determine changes in the permeability of bacterial outer and cytoplasmic membranes simultaneously. Outer membrane permeabilization induced by antimicrobial agents, chlorhexidine and polyhexamethylene biguanide (PHMB), as monitored with the TPP(+) electrode, correlated closely with the ability of the agents to release lipopolysaccharide (LPS) from the outer membrane.  相似文献   

7.
Treatment of biological material by pulsed electric fields is a versatile technique in biotechnology and biomedicine used, for example, in delivering DNA into cells (transfection), ablation of tumors, and food processing. Field exposure is associated with a membrane permeability increase usually ascribed to electroporation, i.e., formation of aqueous membrane pores. Knowledge of the underlying processes at the membrane level is predominantly built on theoretical considerations and molecular dynamics (MD) simulations. However, experimental data needed to monitor these processes with sufficient temporal resolution are scarce. The whole-cell patch-clamp technique was employed to investigate the effect of millisecond pulsed electric fields on DC-3F cells. Cellular membrane permeabilization was monitored by a conductance increase. For the first time, to our knowledge, it could be established experimentally that electroporation consists of two clearly separate processes: a rapid membrane poration (transient electroporation) that occurs while the membrane is depolarized or hyperpolarized to voltages beyond so-called threshold potentials (here, +201 mV and −231 mV, respectively) and is reversible within ∼100 ms after the pulse, and a long-term, or persistent, permeabilization covering the whole voltage range. The latter prevailed after the pulse for at least 40 min, the postpulse time span tested experimentally. With mildly depolarizing or hyperpolarizing pulses just above threshold potentials, the two processes could be separated, since persistent (but not transient) permeabilization required repetitive pulse exposure. Conductance increased stepwise and gradually with depolarizing and hyperpolarizing pulses, respectively. Persistent permeabilization could also be elicited by single depolarizing/hyperpolarizing pulses of very high field strength. Experimental measurements of propidium iodide uptake provided evidence of a real membrane phenomenon, rather than a mere patch-clamp artifact. In short, the response of DC-3F cells to strong pulsed electric fields was separated into a transient electroporation and a persistent permeabilization. The latter dominates postpulse membrane properties but to date has not been addressed by electroporation theory or MD simulations.  相似文献   

8.
Reversible electropermeabilization (or electroporation) of cell membranes is a very efficient method for intracellular delivery of xenomolecules, particularly of DNA. In the case of anchorage-dependent cells, however, enzymatic or mechanical detachment from the substratum is required prior to electropulsing. This can damage the plasma membrane and lead to low transfection yields. Here we present an efficient method for in situ electroporation of mammalian cells while they are attached to a solid substratum. For this purpose an electroporation chamber was constructed that housed a cell culture insert with a cell monolayer grown on a porous filter. By real-time monitoring the transmonolayer resistance, the field pulse parameters resulting in transient and reversible permeabilization of cell membranes were determined for two adherent cell lines, which were found to differ markedly in their sensitivity to electropulsing. Based on the transmonolayer resistance data, the pulsing conditions for optimum electrotransfection of two murine cell lines with plasmid DNA could be established in a very short time. The transfection yield and gene expression were significantly higher in cell monolayers facing the cathode compared to those exposed to field pulses of the reverse direction. This might be due to contribution of the electrophoresis to the translocation of the polyanionic plasmid DNA across the electropermeabilized cell membrane. The experimental setup presented here appears to be a promising tool not only for rapid optimization of in situ electrotransfection of anchorage-dependent cells but also for studying the molecular/biophysical mechanisms of the membrane breakdown and resealing.  相似文献   

9.
Changes in growth kinetics and metabolic activity of microorganisms under the presence of a moderate electric field (MEF) have been hypothesized as being due to temporary permeabilization of cell membranes. We investigated herein the effects of frequency and growth stage on cell membrane permeabilization of Lactobacillus acidophilus OSU 133 during MEF fermentation. Cells were stained with two fluorescent nucleic acid stains: the green, nonselective, cell membrane permeable SYTO 9, and the red, cell membrane impermeable propidium iodide (PI). Fluorescence exhibition post‐treatment was assessed using fluorescence microscopy. Total plate counting was done to determine whether or not the permeabilized population represented live cells. Fermentation treatments investigated were conventional (control) and MEF (2 V/cm, 45, 60, 1,000, 10,000 Hz) at 30°C. Studies were conducted at 45 Hz for lag, exponential, and stationary phases of growth. Low frequency MEF treated cells exhibited significantly greater numbers of red cell counts than conventional treatments; further, no significant differences existed in viable counts between MEF and conventional treatments, suggesting that the red counts represent permeabilized live cells. MEF treatments at the early stage of bacterial growth at 45 Hz exhibited the maximum permeabilization followed by treatments at 60 Hz. MEF treated samples at frequencies higher than 60 Hz did not exhibit red fluorescence. Cells at lag phase showed the greatest susceptibility to permeabilization followed by those at exponential phase. No evidence of electroporation was observed during the stationary phase. To our knowledge, these observations provide the first evidence that cell membrane permeabilization occurs under the presence of electric fields as low as those under MEF. © 2009 American Institute of Chemical Engineers Biotechnol. Prog., 2009  相似文献   

10.
Electroporation relates to the cascade of events that follows the application of high electric fields and that leads to cell membrane permeabilization. Despite a wide range of applications, little is known about the electroporation threshold, which varies with membrane lipid composition. Here, using molecular dynamics simulations, we studied the response of dipalmitoyl-phosphatidylcholine, diphytanoyl-phosphocholine-ester and diphytanoyl-phosphocholine-ether lipid bilayers to an applied electric field. Comparing between lipids with acyl chains and methyl branched chains and between lipids with ether and ester linkages, which change drastically the membrane dipole potential, we found that in both cases the electroporation threshold differed substantially. We show, for the first time, that the electroporation threshold of a lipid bilayer depends not only on the “electrical” properties of the membrane, i.e., its dipole potential, but also on the properties of its component hydrophobic tails.  相似文献   

11.
The permeabilization of biological membranes by electric fields, known as electroporation, has been traditionally performed with square electric pulses. These signals distribute the energy applied to cells in a wide frequency band. This paper investigates the use of sine waves, which are narrow band signals, to provoke electropermeabilization and the frequency dependence of this phenomenon.Single bursts of sine waves at different frequencies in the range from 8 kHz–130 kHz were applied to cells in vitro. Electroporation was studied in the plasma membrane and the internal organelles membrane using calcium as a permeabilization marker. Additionally, a double-shell electrical model was simulated to give a theoretical framework to our results.The electroporation efficiency shows a low pass filter frequency dependence for both the plasma membrane and the internal organelles membrane. The mismatch between the theoretical response and the observed behavior for the internal organelles membrane is explained by a two-step permeabilization process: first the permeabilization of the external membrane and afterwards that of the internal membranes. The simulations in the model confirm this two-step hypothesis when a variable plasma membrane conductivity is considered in the analysis.This study demonstrates how the use of narrow-band signals as sine waves is a suitable method to perform electroporation in a controlled manner. We suggest that the use of this type of signals could bring a simplification in the investigations of the very complex phenomenon of electroporation, thus representing an interesting option in future fundamental studies.  相似文献   

12.
M Hibino  H Itoh    K Kinosita  Jr 《Biophysical journal》1993,64(6):1789-1800
Changes in the membrane conductance of sea urchin eggs, during the course of electroporation, were investigated over the time range of 0.5 microsecond to 1 ms by imaging the transmembrane potential at a submicrosecond resolution with the voltage-sensitive fluorescent dye RH292. When a rectangular electric pulse of moderate intensity was applied across an egg, a position-dependent potential developed synchronously with the pulse, as theory predicts for a cell with an insulating membrane. From the rise and fall times, the membrane capacitance of unfertilized eggs was estimated to be 0.95 microF/cm2 and the intracellular conductance 220 omega.cm. Under an electric pulse of much higher intensity, the rise of the induced potential stopped at a certain level and then slowly decreased on the microsecond time scale. This saturation and subsequent reversal of the potential development was ascribed to the introduction of finite membrane conductance, or permeabilization of the membrane, by the action of the intense pulse (electroporation). Detailed analysis indicated the following: already at 0.5 microsecond in the rectangular electric pulse, the two sides of the egg facing the positive and negative electrodes were porated and gave a high membrane conductance in the order of 1 S/cm2; the conductance on the positive side appeared higher. Thereafter, the conductance increased steadily, reaching the order of 10 S/cm2 by 1 ms. This increase was faster on the negative-electrode side; by 1 ms the conductance on the negative side was more than twice that on the positive side. The recovery of the porated membrane after the pulse treatment was assessed from the membrane conductance estimated in a second electric pulse of a small amplitude. At least two recovery processes were distinguished, one with a time constant of 7 microseconds and the other 0.5 ms, at the end of which the membrane conductance was already < 0.1 S/cm2.  相似文献   

13.
We have conducted experiments quantitatively investigating electroporative uptake kinetics of a fluorescent plasma membrane integrity indicator, propidium iodide (PI), in HL60 human leukemia cells resulting from exposure to 40 μs pulsed electric fields (PEFs). These experiments were possible through the use of calibrated, real-time fluorescence microscopy and the development of a microcuvette: a specialized device designed for exposing cell cultures to intense PEFs while carrying out real-time microscopy. A finite-element electrostatic simulation was carried out to assess the degree of electric field heterogeneity between the microcuvette's electrodes allowing us to correlate trends in electroporative response to electric field distribution. Analysis of experimental data identified two distinctive electroporative uptake signatures: one characterized by low-level, decelerating uptake beginning immediately after PEF exposure and the other by high-level, accelerating fluorescence that is manifested sometimes hundreds of seconds after PEF exposure. The qualitative nature of these fluorescence signatures was used to isolate the conditions required to induce exclusively transient electroporation and to discuss electropore stability and persistence. A range of electric field strengths resulting in transient electroporation was identified for HL60s under our experimental conditions existing between 1.6 and 2 kV/cm. Quantitative analysis was used to determine that HL60s experiencing transient electroporation internalized between 50 and 125 million nucleic acid-bound PI molecules per cell. Finally, we show that electric field heterogeneity may be used to elicit asymmetric electroporative PI uptake within cell cultures and within individual cells.  相似文献   

14.
Traditional electroporation devices use direct current electric fields to stimulate the uptake of oligonucleotides, plasmids, short peptides, and proteins into a variety of cell types. A variation of this widely used technique is now available which relies on radio frequency (RF) electrical pulses. This oscillating type of electrical field reportedly elicits greater uptake of plasmid DNA across the plasma membrane. We evaluated a protocol for RF electroporation of the a human embryonic kidney cell line and a Burkitt's lymphoma (BL) cell line for effeciency of transfection by RF electroporation. The plasmid EGFP, which codes for the widely used fusion protein, enhanced green fluorescent protein (EGFP), was used as a reporter of plasmid uptake after transfections. Transfection efficiency consistently increased approximately 30% from that typically obtained with conventional DC type electroporation and was accompanied by greater survivability of cells. Additionally, in some instances, percent transfection efficiency increased to over 70%. Thus, RF electroporation represents an improved methodology for transfection of human cell lines. Moreover, the RF protocol is simple to incorporate in laboratories already utilizing conventional electroporation devices and techniques.  相似文献   

15.
The creation of a small opening called the fusion pore is a necessary prerequisite for neurotransmitter release from synaptic vesicles. It is known that high intensity electric fields can create pores in vesicles by a process called electroporation. Due to the presence of charged phosphatidylserine (PS) molecules on the inner leaflet of the cell membrane, an electric field that is strong enough to cause electroporation of a synaptic vesicle might be present. It was shown by K. Rosenheck [K. Rosenheck. Biophys J 75, 1237-1243 (1998)] that in a planar geometry, fields sufficient to cause electroporation can occur at intermembrane separations of less than approximately 3 nm. It is frequently found, however, that the cell membrane is not planar but caves inward at the locations where a vesicle is close to it. Indentation of the cell membrane in the fusion region was modelled as a hemisphere and a theoretical study of the electric field in the vicinity of the cell membrane taking into account the screening effect of dissolved ions in the cytoplasm was performed. It was discovered that fields crossing the electroporation threshold occurred at a distance of 2 nm or less, supporting the claim that electroporation could be a possible mechanism for fusion pore formation.  相似文献   

16.
It is widely accepted that electroporation occurs when the cell transmembrane voltage induced by an external applied electric field reaches a threshold. Under this assumption, in order to trigger electroporation in a spherical cell, Schwan’s equation leads to an inversely proportional relationship between the cell radius and the minimum magnitude of the applied electric field. And, indeed, several publications report experimental evidences of an inverse relationship between the cell size and the field required to achieve electroporation. However, this dependence is not always observed or is not as steep as predicted by Schwan’s equation. The present numerical study attempts to explain these observations that do not fit Schwan’s equation on the basis of the interplay between cell membrane conductivity, permeability, and transmembrane voltage. For that, a single cell in suspension was modeled and the electric field necessary to achieve electroporation with a single pulse was determined according to two effectiveness criteria: a specific permeabilization level, understood as the relative area occupied by the pores during the pulse, and a final intracellular concentration of a molecule due to uptake by diffusion after the pulse, during membrane resealing. The results indicate that plausible model parameters can lead to divergent dependencies of the electric field threshold on the cell radius. These divergent dependencies were obtained through both criteria and using two different permeabilization models. This suggests that the interplay between cell membrane conductivity, permeability, and transmembrane voltage might be the cause of results which are noncompatible with the Schwan’s equation model.  相似文献   

17.
Reversible electropermeabilization (electroporation) is widely used to facilitate the introduction of genetic material and pharmaceutical agents into living cells. Although considerable knowledge has been gained from the study of real and simulated model membranes in electric fields, efforts to optimize electroporation protocols are limited by a lack of detailed understanding of the molecular basis for the electropermeabilization of the complex biomolecular assembly that forms the plasma membrane. We show here, with results from both molecular dynamics simulations and experiments with living cells, that the oxidation of membrane components enhances the susceptibility of the membrane to electropermeabilization. Manipulation of the level of oxidative stress in cell suspensions and in tissues may lead to more efficient permeabilization procedures in the laboratory and in clinical applications such as electrochemotherapy and electrotransfection-mediated gene therapy.  相似文献   

18.
Electropermeabilization designates the use of electric pulses to overcome the barrier of the cell membrane. This physical method is used to transfer anticancer drugs or genes into living cells. Its mechanism remains to be elucidated. A position-dependent modulation of the membrane potential difference is induced, leading to a transient and reversible local membrane alteration. Electropermeabilization allows a fast exchange of small hydrophilic molecules across the membrane. It occurs at the positions of the cell facing the two electrodes on an asymmetrical way. In the case of DNA transfer, a complex process is present, involving a key step of electrophoretically driven association of DNA only with the destabilized membrane facing the cathode. We report here at the membrane level, by using fluorescence microscopy, the visualization of the effect of the polarity and the orientation of electric pulses on membrane permeabilization and gene transfer. Membrane permeabilization depends on electric field orientation. Moreover, at a given electric field orientation, it becomes symmetrical for pulses of reversed polarities. The area of cell membrane where DNA interacts is increased by applying electric pulses with different orientations and polarities, leading to an increase in gene expression. Interestingly, under reversed polarity conditions, part of the DNA associated with the membrane can be removed, showing some evidence for two states of DNA in interaction with the membrane: DNA reversibly associated and DNA irreversibly inserted.  相似文献   

19.
Abstract

The creation of a small opening called the fusion pore is a necessary prerequisite for neurotransmitter release from synaptic vesicles. It is known that high intensity electric fields can create pores in vesicles by a process called electroporation. Due to the presence of charged phosphatidylserine (PS) molecules on the inner leaflet of the cell membrane, an electric field that is strong enough to cause electroporation of a synaptic vesicle might be present. It was shown by K. Rosenheck [K. Rosenheck. Biophys J 75, 1237–1243 (1998)] that in a planar geometry, fields sufficient to cause electroporation can occur at intermembrane separations of less than ~3 nm. It is frequently found, however, that the cell membrane is not planar but caves inward at the locations where a vesicle is close to it. Indentation of the cell membrane in the fusion region was modelled as a hemisphere and a theoretical study of the electric field in the vicinity of the cell membrane taking into account the screening effect of dissolved ions in the cytoplasm was performed. It was discovered that fields crossing the electroporation threshold occurred at a distance of 2 nm or less, supporting the claim that electroporation could be a possible mechanism for fusion pore formation.  相似文献   

20.
Exposing eukaryotic cells to brief, high voltage electrical fields can induce the uptake of exogenous materials, presumably through the transient formation of micropores in the cell membrane. This phenomenon has been exploited for the introduction of cloned DNA molecules into cells for permanent transformation or for transient expression and analysis of gene products. The magnitude and characteristics of the generated electrical field are critical for successful electroporation and simple, transient expression assays using indicator genes allow the calibration and optimization of electroporation conditions for a wide variety of eukaryotic cell types. These techniques may allow the genetic modification of a variety of host cells which cannot be easily transformed by other methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号