首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Among antitumor oxazaphosphorine drugs, the prodrug ifosfamide (IFO) and its analogs require metabolic activation by specific liver cytochrome P450 (CYP) enzymes to become therapeutically active. New 7,9-dimethyl-ifosfamide analogs have shown greater cytotoxic activity than IFO, whereas side-chain oxidation still occurred leading to monochloroacetone after N-dechloropropylation. A sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed and validated for the simultaneous quantitation of the prodrug 7S,9S-dimethyl-ifosfamide (diMeIFO) and its two inactive metabolites, N(2)- and N(3)-deschloropropyl-dimethylifosfamide (N(2)-DCP-diMeIFO and N(3)-DCP-diMeIFO) in mouse plasma. After protein precipitation with methanol, the analytes were separated by isocratic reversed-phase chromatography with (methanol/ammonium formate pH 5.5, 60:40, v/v) and detected by tandem mass spectrometry using multiple reaction monitoring of transitions ions m/z 289→168 for diMeIFO, m/z 213→168 for N(2)-DCP-diMeIFO, m/z 213→92 for N(3)-DCP-diMeIFO and m/z 261→154 for IFO (internal standard). The calibration curves were linear over the concentration range of 20-10,000ng/mL for the three analytes. Mean extraction recoveries from mouse plasma were 99, 96, 99 and 100% for diMeIFO, N(2)-DCP-diMeIFO, N(3)-DCP-diMeIFO and IFO, respectively. The lower limit of quantitation for diMeIFO and its metabolites was 20 ng/mL in 50 μL plasma. The method was accurate with calculated bias from -5.8 to 4.0% for diMeIFO, from -1.1 to 10.6% for N(2)-DCP-diMeIFO and from -6.9 to 9.8% for N(3)-DCP-diMeIFO, and precise with coefficients of variation lower than 6.8%, 7.8% and 14.3%, respectively. The assay was successfully applied to a preliminary pharmacokinetic study of diMeIFO and of its metabolites in mice.  相似文献   

2.
Felbamate (2-phenyl-1,3-propanediol dicarbamate) is a second generation antiepileptic drug used to treat seizures refractory to other antiepileptic drugs. With approximately 3500 new patients exposed annually, several important pharmacologic interaction questions remain unanswered necessitating the need for rapid and accurate methods of felbamate analysis in biological matrices. To this end, a rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for the measurement of felbamate in mouse plasma and tissues and human plasma. Plasma (100 μL) and tissues homogenates (100 μL of 100 mg/mL) were spiked with internal standard (carisoprodol) prior to protein precipitation with acetonitrile. Samples were chromatographed on a XBridge Phenyl, 2.5 μm, 4.6 mm×50 mm column with quantitation by internal standard reference monitoring of the ion transitions m/z 239→117 for felbamate and m/z 261→176 for carisoprodol. Calibration curves were linear from 2.5 to 500 ng/mL in mouse or human plasma and 25-5000 pg/mg in tissue homogenates. Recoveries were greater than 97% for plasma and homogenates with accuracies >92% in any of the mouse matrices and >88% in human plasma. Comparable accuracies and precision were found with and without the use of the internal standard in preparation of the calibration curves and suggest that the internal standard may not be required.  相似文献   

3.
A sensitive method for the determination of lapatinib (GW572016) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Plasma samples (100 microL) were prepared using solid phase extraction (SPE) columns, and 6.0 microL of the reconstituted eluate was injected onto a Phenomenex CuroSil-PFP 3 mu analytical column (50 mm x 2.0mm) with an isocratic mobile phase. Analytes were detected with a PE SCIEX API-365 LC-MS/MS system at unit (Q1) and low (Q3) resolution in positive multiple reaction monitoring mode (m/z 581 (precursor ion) to m/z 364 (product ion) for lapatinib). The mean recovery for lapatinib was 75% with a lower limit of quantification of 15 ng/mL (S/N=11.3, CV< or =14%). This method was validated over a linear range of 100-10,000 ng/mL, and results from a 5-day validation study demonstrated good within-day and between-day precision and accuracy. This method has been used to measure plasma lapatinib concentrations in a Phase I study in children with cancer.  相似文献   

4.
Bestatin is a low molecular weight aminopeptidase inhibitor originally isolated from culture filtrates of Streptomyces olivoreticuli. We have developed a sensitive, specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the quantitative determination of bestatin in rat plasma using granisetron as the internal standard. The analyte and internal standard were isolated from 50 microL plasma samples by solid phase extraction (SPE). Reverse-phase HPLC separation was accomplished on a Lichrospher C18 column (4.6 mm x 50 mm, 5 microm) with a mobile phase composed of methanol-water-formic acid (70:30:0.5, v/v/v) at a flow rate of 0.8 mL/min. The method had a chromatographic total run time of 3 min. A Varian 1200L electrospray tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 309.2-->120.0 (bestatin) and 313.4-->138.0 (granisetron) used for quantitation. The method was sensitive with a lower limit of quantitation (LLOQ) of 5 ng/mL, with good linearity (r2 >or= 0.999) over the linear range of 5-2000 ng/mL. All the validation data, such as accuracy, precision, and inter-day repeatability, were within the required limits. The method was successfully applied to pharmacokinetic study of bestatin in rats.  相似文献   

5.
A sensitive method for the determination of Cloretazine (VNP40101M) and its metabolite (VNP4090CE) with an internal standard (ISTD) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Acidified plasma samples (500 microL) were prepared using solid phase extraction (SPE) columns, and 25 microL of the reconstituted sample was injected onto an Ascentis C18 HPLC column (3 microm, 5 cmx2.1 mm) with an isocratic mobile phase. Analytes were detected with an API-3000 LC-MS/MS System at unit (Q1) and low (Q3) resolution in negative multiple reaction monitoring mode: m/z 249.0 (precursor ion) to m/z 114.9 (product ion) for both Cloretazine (at 3.64 min) and VNP4090CE (at 2.91 min), and m/z 253.0 (precursor ion) to m/z 116.9 (product ion) for the ISTD. The mean recovery for Cloretazine (VNP40101M) and its metabolite (VNP4090CE) was greater than 87% with a lower limit of quantification of 1.0 ng/mL for Cloretazine (S/N=9.7, CV相似文献   

6.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and fully validated to determine HS270, a new histone deacetylase (HDAC) inhibitor, in rat plasma using SAHA as the internal standard (IS). After a single step liquid-liquid extraction with acetoacetate, analytes were subjected to LC-MS/MS analysis using positive electro-spray ionization (ESI(+)) under selected reaction monitoring mode (SRM). The chromatographic separation was achieved on a Hypurity C(18) column (50 mm × 2.1 mm, i.d., 5 μm). The MS/MS detection was conducted by monitoring the fragmentation of m/z 392.3→100.1 for HS270, m/z 265.1→232.1 for IS. The method had a chromatographic running time of 2.5 min and linear calibration curves over the concentrations of 0.5-1000 ng/mL. The recovery of the method was 70.8-82.5% and the lower limit of quanti?cation (LLOQ) was 0.5 ng/mL. The intra- and inter-batch precisions were less than 15% for all quality control samples at concentrations of 1.0, 100.0, and 750.0 ng/mL. The validated LC-MS/MS method has successfully applied to a HS270 pharmacokinetic study after oral doses of 25, 50, 100, 200 mg/kg, and i.v. dose of 5 mg/kg to rats.  相似文献   

7.
A rapid, specific and sensitive liquid chromatography-tandem mass spectrometry (LC/MS/MS) method was developed for simultaneous quantitation of six Aconitum alkaloids, i.e. aconitine (AC), mesaconitine (MA), hypaconitine (HA), benzoylaconine (BAC), benzoylmesaconine (BMA) and benzoylhypaconine (BHA) in human plasma collected from 18 healthy volunteers after intravenous drop infusion of "SHEN-FU" injectable powder in three different dosages. Lappaconitine was selected as the internal standard (IS). LC/MS/MS system coupled with an electrospray ionization (ESI) source was performed in multiple-reaction monitoring (MRM) mode. The transitions of the Aconitum alkaloids executed as following: m/z 646.3-->586.0 for AC; m/z 632.4-->573.1 for MA; m/z 616.2-->556.1 for HA; m/z 604.2-->104.8 for BAC; m/z 590.1-->104.8 for BMA; m/z 574.1-->104.8 for BHA; m/z 585.2-->161.8 for IS. Sample preparation was performed with solid-phase extraction (SPE) on a 1 mL HLB cartridge prior to analysis. The separation was applied on a Waters C(18) column (1.7 microm, 2.1 mm x 100 mm) and a gradient elution of methanol and 0.1% formic acid-water was used as mobile phase. The retention time was less than 4.5 min. The concentrations ranged from 0.1 to 1000 ng/mL for all six Aconitum alkaloids and showed a good linearity with the correlation coefficient (r(2)) >0.995. The validated method was employed to simultaneous quantitation and successfully used for the first time for the pharmacokinetic evaluation of the six Aconitum alkaloids after intravenous drop administration of "SHEN-FU" injectable powder in phase I clinical trial.  相似文献   

8.
A new LC-ESI-MS/MS assay method has been developed and validated for the quantification of swertiamarin, a representative bioactive substance of Swertia plants, in rat plasma using gentiopicroside, an analog of swertiamarin on chemical structure and chromatographic action, as the internal standard (IS). The swertiamarin and IS were extracted from rat plasma using solid-phase extraction (SPE) as the sample clean-up procedure, and they were chromatographed on a narrow internal diameter column (Agilent ZORBAX ECLIPSE XDB-C(18) 100 mm × 2.1 mm, 1.8 μm) with the mobile phase consisting of methanol and water containing 0.1% acetic acid (25:75, v/v) at a flow rate of 0.2 mL/min. The detection was performed on an Agilent G6410B tandem mass spectrometer by negative ion electrospray ionisation in multiple-reaction monitoring mode while monitoring the transitions of m/z 433 [M+CH(3)COO](-)→179 and m/z 415 [M+CH(3)COO](-)→179 for swertiamarin and IS, respectively. The lower limit of quantification (LLOQ) was 5 ng/mL within a linear range of 5-1000 ng/mL (n=7, r(2)≥0.994), and the limit of detection (LOD) was demonstrated as 1.25 ng/mL (S/N≥3). The method also afforded satisfactory results in terms of sensitivity, specificity, precision (intra- and inter-day), accuracy, recovery, freeze/thaw, long-time stability and dilution integrity. This method was successfully applied to determination of the pharmacokinetic properties of swertiamarin in rats after oral administration at a dose of 20 mg/kg. The following pharmacokinetic parameters were obtained (mean): maximum plasma concentration, 1920.1 ng/mL; time to reach maximum plasma concentration, 0.945 h; elimination half-time, 1.10h; apparent total clearance, 5.638 L/h/kg; and apparent volume of distribution, 9.637 L/kg.  相似文献   

9.
The collection of oral fluid for drug testing is easy and non-invasive. This study developed a drug testing method using ultra-high performance liquid chromatography/tandem mass spectrometry (UHPLC-MS/MS) in selected-reaction monitoring (SRM) mode. We tested the method on the analysis of four opiates and their metabolites, five amphetamines, flunitrazepam and its two metabolites, and cocaine and its four metabolites in oral fluid. 100-μL samples of oral fluid were diluted with twice the amount of water then spiked with isotope-labeled internal standards. After the samples had undergone high-speed centrifugation for 20 min, we analyzed the supernatant. The recovery of the sample preparation ranged from 81 to 108%. We compared the performance of electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI). The ion suppression of most analytes on ESI (28-78%) was lower than that of APCI and APPI. A post-column flow split (5:1) did not reduce the matrix effect on ESI. Direct APPI performed better than dopant-assisted APPI using toluene. ESI, APCI and APPI limits of quantitation mostly ranged from 0.11 to 1.9 ng/mL, 0.02 to 2.2 ng/mL and 0.02 to 2.1 ng/mL, respectively, but were much higher on amphetamine and ecgonine methyl ester (about 2.7-4.7 ng/mL, 8.7-14 ng/mL, and 10-19 ng/mL, respectively). Most of the bias percentages (accuracy) and relative standard deviations (precision) on spiked samples were below 15%. This method greatly simplifies the process of sample preparation and shortens the chromatographic time to only 7.5 min per run and is able to detect analytes at sub-ppb levels.  相似文献   

10.
Midazolam is an ultra short acting benzodiazepine derivative and a specific probe for phenotyping cytochrome P450 (P450) 3A4/5 activity. A rapid, sensitive, and selective LC–MS/MS method was developed for simultaneous quantitation of midazolam and its metabolites (1′-hydroxymidazolam and 4-hydroxymidazolam). Deuterated (D5) analog of midazolam was utilized as an internal standard. Sample preparation either from human plasma (100 μL) or liver microsomal incubations involved a simple protein precipitation using acetonitrile (900 μL) with an average recovery of >90% for all compounds. The chromatographic separation was achieved using Zorbax-SB Phenyl, Rapid Resolution HT (2.1 mm × 100 mm, 3.5 μm) and a gradient elution with 10 mM ammonium acetate in 10% methanol (A) and acetonitrile (B). The flow rate was 0.25 mL/min and total run time was 5.5 min. Calibration curves were linear over the concentration range of 0.100–250 ng/mL. The lower limit of quantitation (LLOQ) was 0.1 ng/mL for all three analytes. The accuracy and precision, estimated at LLOQ and three concentration levels of quality control samples in six replicates, were within 85–115%. In conclusion, a robust, simple and highly sensitive analytical method was developed and validated for the analysis of midazolam and its metabolites. This method is suitable for characterizing the P450 3A4/5 activity in vitro or in human pharmacokinetic studies allowing administration of smaller doses of midazolam.  相似文献   

11.
本文建立了一种快速、高灵敏的HPLC-MS/MS法用于检测人血浆中的草乌甲素浓度。血浆样品采用沃特斯HLB小柱进行固相萃取,汉邦C18色谱柱(150 mm×4.6 mm,5μm)进行分离,流动相为甲醇∶水(85∶15,v/v),水相含10 mmol/L的醋酸铵和0.1%的甲酸。采用ESI源和多反应监测(MRM)的方式进行检测,草乌甲素及内标的反应离子对分别为644.4/584.4和237.2/194.2,草乌甲素血药浓度在0.010~1.0 ng/mL范围内线性关系良好,最低定量限为0.010 ng/mL可以满足口服0.4 mg草乌甲素后血药浓度的检测,日内日间及质控样品精密度及准确度均在允许范围内。本检测方法被成功的应用在中国健康志愿者生物等效性研究中,20名志愿者口服0.4 mg草乌甲素试验制剂和参比制剂后主要药代动力学参数分别如下:Cmax(0.325±0.110),(0.323±0.115)ng/mL;AUC0-16(1.627±0.489),(1.732±0.556)ng.h/mL;AUC0-∞(1.730±0.498),(1.831±0.562)ng.h/mL;t1/2(4.26±0.95),(3.80±0.90)h;Tmax(1.34±0.54),(1.83±0.99)h。  相似文献   

12.
Ursolic acid is a hydroxy pentacyclic triterpene, which proved to have sedation, anti-inflammatory, antibacterial, antiulcer and anti-cancer activities. An ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method with high selectivity, sensitivity and throughput has been established and validated for quantitation of total ursolic acid in human plasma. Plasma samples were pretreated by liquid-liquid extraction with ethyl acetate and were chromatographed by an ACQUITY UPLC BEH C(8) column (100 mm×2.1 mm, I.D., 1.7 μm) using mobile phase consisting of acetonitrile and 10 mM ammonium formate (90:10, v/v) at 0.2 mL/min. The duration of chromatography analysis was 3 min. The multiple reaction monitoring (MRM) was performed at m/z 455.1→455.0 for ursolic acid and m/z 469.3→425.2 for glycyrrhetinic acid (internal standard, IS) in the negative ion mode with electrospray ionization (ESI) source. The assay showed good linearity over the range of 10-5000 ng/mL for ursolic acid in human plasma with a lower limit of quantitation of 10 ng/mL. The mean extraction recovery was 73.2±4.5% and the matrix ion suppression ranged from -11.4% to -5.6%. The intra- and inter-day precisions were less than 7.0% and 7.2%, respectively, and the accuracy was within ±2.0%. Ursolic acid was stable during the analysis and the storage period. The validated method has been successfully applied to a pharmacokinetic study after intravenous infusion of Ursolic Acid Nano-liposomes to healthy volunteers.  相似文献   

13.
PM01218 is a novel marine-derived alkaloid and has shown potent growth inhibitory activity against several human cancer cell lines. A rapid and sensitive high performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) method was developed and validated to quantify PM01218 in mouse and rat plasma. The lower limit of quantitation (LLOQ) was 0.05 ng/mL. The calibration curve was linear from 0.05 to 100 ng/mL (R(2)>0.999). The assay was specifically based on the multiple reaction monitoring (MRM) transitions at m/z 278.4-->184.2, no endogenous material interfaced with the analysis of PM01218 and its internal standard from blank mouse and rat plasma. The mean intra- and inter-day assay accuracy remained below 15 and 8%, respectively, for all calibration standards and QC samples. The intra- and inter-day assay precision was less than 12.8 and 8.5% for all QC levels, respectively. The utility of the assay was demonstrated by pharmacokinetics studies of i.v. (bolus) PM01218 on SD rats.  相似文献   

14.
A sensitive and reliable method for the determination of gamma-aminobutyric acid (GABA), a major inhibitory neurotransmitter, in human plasma and cerebrospinal fluid (CSF) has been developed. The method is based on capillary liquid chromatography (LC)/tandem mass spectrometry (MS/MS) using deuterium-labeled GABA (gamma-aminobutyric acid-2,2-D(2), GABA-d(2)) as internal standard. Pre-column derivatization with 7-fluoro-4-nitrobenzoxadiazole (NBD-F) was deployed, allowing both effective in-line pre-concentration and sensitive tandem MS detection of the analyte. An extraction column (10 mm x 0.25 mm, 7 microm, C(18)) was used for preconcentrating and stacking the sample. Separation was carried out on an analytical column (50 mm x 0.25 mm, 5 microm, C(18)). Characteristic precursor-to-product ion transitions, m/z 267--> 249 (for NBD-GABA) and m/z 269--> 251 (for NBD-GABA-d(2)) were monitored for the quantification. A linear calibration curve from 10 to 250 ng/mL GABA with an r(2) value of 0.9994 was obtained. Detection limit was estimated to be 5.00 ng/mL GABA (S/N = 3). Human plasma and CSF samples were analyzed. The concentrations of GABA were found to be 98.6 +/- 33.9 ng/mL (mean +/- S.D., n = 12), and 44.3 +/- 10.0 ng/mL (n = 6) in plasma and CSF, respectively.  相似文献   

15.
A new drug, quick-acting anti-motion capsule (QAAMC) composed of d-amphetamine sulfate, dimenhydrinate and ginger extraction has been studied for anti-motion-sickness use. We have developed a sensitive, specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the quantitative determination of d-amphetamine and diphenhydramine, the main effective components of the QAAMC, using pseudoephedrine as the internal standard. The analytes and internal standard were isolated from 200 microL plasma samples by a simple liquid-liquid extraction (LLE). Reverse-phase HPLC separation was accomplished on a Zorbax SB-C18 column (100 mm x 3.0 mm, 3.5 microm) with a mobile phase composed of methanol-water-formic acid (65:35:0.5, v/v/v) at a flow rate of 0.2 mL/min. The method had a chromatographic total run time of 5 min. A Varian 1200 L electrospray tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 136.0-->91.0 (D-amphetamine), 256.0-->167.0 (diphenhydramine) and 166.1-->148.0 (IS) used for quantitation. The method was sensitive with a lower limit of quantitation (LLOQ) of 0.5 ng/mL for d-amphetamine and 1 ng/mL for diphenhydramine, with good linearity in the range 0.5-200 ng/mL for D-amphetamine and 1-500 ng/mL for diphenhydramine (r(2)> or =0.9990). All the validation data, such as accuracy, precision, and inter-day repeatability, were within the required limits. The method was successfully applied to pharmacokinetic study of the QAAMC in beagle dogs.  相似文献   

16.
A rapid, sensitive and specific method to determination of ambroxol in human plasma using high performance liquid chromatography coupled with electrospray ionization mass spectrometry (HPLC-MS/ESI) was described. Ambroxol and the internal standard (I.S.), fentanyl, were extracted from plasma by N-hexane-diethyl ether (1:1, v/v) after alkalinized with ammonia water. A centrifuged upper layer was then evaporated and reconstituted with 100 microl mobile phase. Chromatographic separation was performed on a BDS HYPERSIL C18 column (250 mmx4.6 mm, 5.0 microm, Thermo electron corporation, USA) with the mobile phase consisting of 30 mM ammonium acetate (0.4% formic acid)-acetonitrile (64:36, v/v) at a flow-rate of 1.2 mL min(-1). The total run time was 5.8 min for each sample. Detection and quantitation was performed by the mass spectrometer using selected ion monitoring at m/z 261.9, 263.8 and 265.9 for ambroxol and m/z 337.3 for fentanyl. The calibration curve was linear within the concentration range of 1.0-100.0 ng mL(-1) (r=0.9996). The limit of quantification was 1.0 ng mL(-1). The extraction recovery was above 83.3%. The methodology recovery was higher than 93.8%. The intra- and inter-day precisions were less than 6.0%. The method is accurate, sensitive and simple for the study of the pharmacokinetics and metabolism of ambroxol.  相似文献   

17.
A precise, sensitive and high throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of trazodone (TRZ) and its primary metabolite, m-chlorophenylpiperazine (mCPP), in human plasma was developed and validated. The analytes and the internal standard-nefazodone were extracted from 500 microL aliquots of human plasma via liquid-liquid extraction in n-hexane. Chromatographic separation was achieved in a run time of 2.5 min on a Betabasic cyano column (100 mm x 2.1 mm, 5 microm) under isocratic conditions. Detection of analytes and IS was done by tandem mass spectrometry, operating in positive ion and multiple reaction monitoring (MRM) acquisition mode. The protonated precursor to product ion transitions monitored for TRZ, mCPP and IS were m/z 372.2-->176.2, 197.2-->118.1 and 470.5-->274.6 respectively. The method was fully validated for its sensitivity, selectivity, accuracy and precision, matrix effect, stability study and dilution integrity. A linear dynamic range of 10.0-3000.0 ng/mL for TRZ and 0.2-60.0 ng/mL for mCPP was evaluated with mean correlation coefficient (r) of 0.9986 and 0.9990 respectively. The intra-batch and inter-batch precision (%CV) across five validation runs (LLOQ, lower limit of quantitation; LQC, low quality control; MQC, middle quality control; HQC, high quality control and ULOQ, upper limit of quantitation) was < or =8.4% for both the analytes. The method was successfully applied to a bioequivalence study of 100mg trazodone tablet formulation in 36 healthy Indian male subjects under fasting and fed conditions.  相似文献   

18.
A rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated to quantify artemisinin in rat serum. The lower limit of quantification (LLOQ) was 4 ng/mL. The calibration curve was linear from 4 ng/mL to 10,000 ng/mL (R=0.998). The assay was based on the selected reaction monitoring (SRM) transitions at m/z 305.4-151.10 for artemisinin and m/z 335.2-163.10 for arteether (internal standard). The artemisinin and internal standard can be separated from endogenous interferences in rat serum. Inter- and intra-day assay variation was less than 15%. The extraction recoveries ranged from 80.0 to 107.3% at the three concentrations (5000, 2000, and 200 ng/mL). This method was successfully applied to pharmacokinetic studies of artemisinin after intravenous and oral administration to rats.  相似文献   

19.
A sensitive high performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) assay was developed to determine raltitrexed in human plasma. After addition of benazeprilat as the internal standard (IS), methanol was used to produce a protein-free extract. Chromatographic separation was achieved with a Zorbax SB-C18 column (Narrow-Bore 2.1 mmx150 mm, 5-microm) using a mobile phase of acetonitrile-water containing 0.1% formic acid and 2% methanol (21.9:78.1, v/v). Raltitrexed was determined with electrospray ionization-mass spectrometry. HPLC-ESI-MS was performed in the selected ion monitoring (SIM) mode using target ions at [M+H]+ m/z 459.1 for raltitrexed and [M+H]+ m/z 397.1 for IS. Calibration curves were linear over the range of 2.0-3000 ng/ml. The lower limit of quantification was 2.0 ng/ml. The intra- and inter-batch variability values were less than 6.7% and 10.3%, respectively. The mean plasma extraction recovery of raltitrexed was in the range of 85.2-91.1%. The method was successfully applied to determine the plasma concentrations of raltitrexed in eight Chinese colorectal cancer patients.  相似文献   

20.
An analytical method based upon liquid chromatography coupled to ion trap mass spectrometry (MS) detection with electrospray ionization interface has been developed for the simultaneous identification and quantification of droperidol and ondansetron in human plasma. The two drugs were isolated from 0.5 mL of plasma using a basic liquid-liquid extraction with diethyl ether/heptane (90/10, v/v) and tropisetron and haloperidol as internal standards, with satisfactory extraction recoveries. They were separated on a 5-μm C(18) Highpurity column (150 mm×2.1 mm I.D.) maintained at 30°C. The elution was achieved isocratically with a mobile phase of 2 mM HCOONH(4) pH 3.8 buffer/acetonitrile (60/40, v/v) at a flow rate of 200 μL/min. Data were collected either in full-scan MS mode at m/z 100-450 or in full-scan MS-MS mode, selecting the [M+H] (+) ion at m/z=294.0 for ondansetron, m/z=285.2 for tropisetron, m/z=380.0 for droperidol and m/z=376.0 for haloperidol. The most intense daughter ion of ondansetron (m/z=212.0) and droperidol (m/z=194.0) were used for quantification. Retention times for tropisetron, ondansetron, droperidol and haloperidol were 2.50, 2.61, 3.10 and 4.68 min, respectively. Calibration curves were linear for both compounds in the 0.50-500 ng/mL range. The limits of detection and quantification were 0.10 ng/mL and 0.50 ng/mL, respectively. The intra- and inter-assay precisions were lower than 6.4% and intra- and inter-assay recoveries were in the 97.6-101.9% range for the three 3, 30 and 300 ng/mL concentrations. This method allows simultaneous and rapid measurement of droperidol and ondansetron, which are frequently co-administrated for the prevention of postoperative nausea and vomiting.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号