首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 34 毫秒
1.
Two water soluble porphyrins: meso-tetra-4-N-methylpyridyl-porphyrin iodide (P1) and 5,10-di-(4-acetamidophenyl)-15,20-di-(4-N-methylpyridyl) porphyrin (P2) were synthesised and evaluated in respect to their photochemical and photophysical properties as well as biological activity. Cytotoxic and phototoxic effects were evaluated in human malignant melanoma Me45 line using clonogenic assay, cytological study of micronuclei, apoptosis and necrosis frequency and inhibition of growth of megacolonies. Both porphyrins were characterised by high UV and low visible light absorptions. Dark toxicity measured on the basis of the clonogenic assay and inhibition of megacolony growth area indicated that P1 was non-toxic at concentrations up to 50 microg/ml (42.14 microM) and P2 at concentrations up to 20 microg/ml (16.86 microM). The photodynamic effect induced by red light above 630 nm indicated that both porphyrins were able to inhibit growth of melanoma megacolonies at non-toxic concentrations. Cytologic examination showed that the predominant mode of cell death was necrosis.  相似文献   

2.
We compared the detection rate of cervical neoplasias between a liquid-based cytology (LBC) method using SurePath and the conventional method. We also studied the feasibility of human papillomavirus (HPV) typing by linear array assay. Cytological specimens from 1551 Japanese women were prepared using the conventional and SurePath methods; the cytological and histological results from biopsy samples were compared. HPV typing using an HPV linear array assay was carried out on residual specimens using the SurePath method. The cytodiagnostic results showed a concordance rate of 85.3% (Κ= 0.46) between the two methods. The sensitivity of lesions histopathologically diagnosed as CIN1 or above was not significantly different between the two methods (P = 0.575-1.000). The receiver operating characteristic curve analysis of the detectability in CIN2 or above revealed no significant difference between the two methods (P = 0.096). Among the 44 patients who underwent HPV typing using a linear array assay, 33 samples were eligible for HPV testing and were stored at ambient temperature. In conclusion, the SurePath and conventional methods have equivalent abilities for detecting cervical lesions. After preparation for cytological diagnosis, use of the remaining cells from the SurePath specimens to perform HPV typing using the linear array method could be feasible.  相似文献   

3.
A liquid chromatographic-tandem mass spectrometric (LC-MS-MS) assay was developed and validated to quantitatively determine olanzapine (OLZ) concentrations in human blood. Liquid-liquid extraction, using n-butanol:cyclohexane (3:47, v/v), was used to isolate OLZ and its internal standard, LY170158, from the biological matrix. Chromatographic resolution of OLZ from endogenous interferences and known metabolites was accomplished with a MetaChem Monochrom HPLC column (4.6 x 150 mm, d(p) 5 microm). Detection occurred using a Perkin-Elmer Sciex API III Plus triple quadrupole mass spectrometer using positive ion APCI and multiple reaction monitoring (MRM). The linear dynamic range was from 5 to 500 ng ml(-1) based on a 0.25-ml aliquot of human blood. The inter-day precision (%RSD) and accuracy (%RE) ranged from 3.65 to 10.64 and from -2.14 to 3.07, respectively. Modifications to an existing assay for the determination of OLZ in human plasma were necessary. A different structural analog was used as the internal standard due to instability observed for the original analog when using human blood as the matrix. A second modification was the addition of the anti-oxidant sodium ascorbate to inhibit degradation of OLZ in human blood, as has been noted by other investigators. Upon fortification of human blood with sodium ascorbate (final concentration, 0.33 mM), OLZ was found to be stable for at least 1 week at -70 degrees C as well as through two freeze-thaw cycles. This assay, which will be used to investigate the distribution of OLZ in human blood, grants insight into the proper sample handling conditions needed to perform valid determinations of OLZ in human blood.  相似文献   

4.
Oxidized protein hydrolase (OPH), an 80 kDa serine protease whose activity is inhibited by diisopropyl fluorophosphate (DFP), has been isolated from human erythrocytes [Fujino, T. et al. (1998) J. Biochem. 124, 1077-1085]. The presence of OPH in various biological samples was examined by enzyme-linked immunosorbent assay (ELISA) and immunoblotting using an anti-OPH antibody raised against OPH purified from human erythrocytes, and by [(3)H]DFP-labeling and successive SDS-PAGE/fluorography. Solubilized samples of human cell lines including K-562 cells, THP-1 cells and Jurkat cells, and rat tissues including brain, heart, liver, kidney, and testis, inhibited the anti-OPH antibody binding to OPH in ELISA. Immunoblotting of lysates of K-562 cells, THP-1 cells and Jurkat cells showed four immunoreactive protein bands including an 80 kDa protein. Immunoprecipitation of the [(3)H]DFP-labeled K-562 cell lysate and successive SDS-PAGE/fluorography showed the presence of only the 80 kDa DFP-reactive protein with OPH antigenic activity. The level of the 80 kDa immunoreactive protein in K-562 cells rose as the cells differentiated toward erythrocytes. Immunoblotting of human and rat plasma showed two immunoreactive protein bands, including the 80 kDa protein, and SDS-PAGE/fluorography of [(3)H]DFP-labeled rat and human plasma showed the presence of only the 80 kDa DFP-reactive protein. The results indicate that OPH is present in a wide variety of biological samples.  相似文献   

5.
A validated, simple and universal HPLC-UV method for the determination of cimetidine, famotidine, nizatidine and ranitidine in human urine is presented. This is the first single HPLC method reported for the analysis of all four H(2) antagonists in human biological samples. This method was also utilized for the analysis of ranitidine and its metabolites in human urine. All calibration curves showed good linear regression (r(2)>0.9960) within test ranges. The method showed good precision and accuracy with overall intra- and inter-day variations of 0.2-13.6% and 0.2-12.1%, respectively. Separation of ranitidine and its metabolites using this assay provided significantly improved resolution, precision and accuracy compared to previously reported methods. The assay was successfully applied to a human volunteer study using ranitidine as the model compound.  相似文献   

6.
A novel, highly sensitive method for the determination of pilocarpic acid (PA) in human plasma is described. In addition, the method provides for the conversion of the lactone, pilocarpine (P), to PA so that a total drug presence can be determined. Using novel high-performance liquid chromatographic conditions capable of separating P, isopilocarpine (I-P), PA and isopilocarpic acid (I-PA) from each other and from endogenous plasma impurities, it was confirmed that P exclusively and quantitatively converts to PA in heparinized human plasma during storage. For the determination of PA, the selective extraction of PA from protein-free plasma was accomplished using two different solid-phase extraction (SPE) cartridges in two consecutive SPE steps. After extraction, PA was lactonized with trifluoroacetic acid back to P, and both P and an internal standard were acylated using heptafluorobutyric anhydride (HFBA). The trifluoroacetylated derivatives were monitored using gas chromatography (GC) with mass spectrometric (MS) detection. This procedure allowed the sensitive and reliable determination of PA with a limit of quantification (LOQ) of 1 ng/ml, which could not be achieved using previously described methods. The assay was validated in the concentration range of 1 to 10 ng/ml with an intra-day precision (expressed as the coefficient of variation, C.V.) ranging from 9.9 to 0.5%. Inter-day precision for the quality control standard at 2.5 ng/ml showed a C.V. of 10.2%. Accuracy ranged from 94 to 102%. The assay was used to monitor the maximum systemic exposure to P, administered by the ocular route, in terms of total plasma PA (P and PA).  相似文献   

7.
In the present work we have studied the occurrence of different tachykinins (substance P (SP), neurokinin A (NKA) and neuropeptide K (NPK)) in human distal bronchi and pulmonary arteries by means of radioimmunoassay (RIA) and high performance liquid chromatography (HPLC). We have also compared the biological effects of different tachykinins on isolated human bronchi and pulmonary arteries in vitro. The concentration of immunoreactive SP using antiserum SP2 in the pulmonary arteries was higher (1.34 +/- 0.15 pmol/g) than in the bronchi (0.56 +/- 0.05 pmol/g). The contents of other tachykinins than SP measured using antiserum K12 was on the other hand considerably higher in the bronchi (0.33 +/- 0.14 pmol/g) than in pulmonary arteries (0.13 +/- 0.02 pmol/g). Immunoreactive materials corresponding to SP, NKA and NPK were identified in bronchial extracts by RIA combined with HPLC, which also indicated the presence of an eledoisin (ELE)-like component. In vitro studies showed that NKA was the most potent of the tachykinins as a bronchoconstrictor agent, being several hundred-fold more active than SP, acetylcholine and histamine. NPK had an intermediate potency. The bronchoconstrictor effect of NKA was unaffected by atropine, mepyramine and cimetidine. The tachykinins SP and NKA had on the other hand, a rather equal potency in inducing relaxation of serotonin precontracted pulmonary arteries. In conclusion, multiple tachykinins are present in lower airways of man. These peptides exert different biological activities whereby NKA is a very active bronchoconstrictor agent compared to SP while both NKA and SP have rather similar relaxatory activities of vascular smooth muscle.  相似文献   

8.
A truncate form of human aromatase cDNA that corresponds to the recently identified rat cortical type aromatase mRNA variant (Yamada-Mouri et al., J. Steroid Biochem. Molec. Biol., 60: 325-329, 1997) has been generated, and the amino-terminus deleted form of the enzyme has been expressed in CHO cells. The resulting product lacking 102 residues from the N-terminus of aromatase (i.e. 102-aromatase) showed an extremely low enzyme activity using an 'In-cell' assay. A strong aromatase activity, however, was observed for the delta102-aromatase using an in vitro method on the solublized preparations. The in vitro activity was dependent on both incubation time and NADPH concentration as well as inclusion of NADPH-cytochrome P450 reductase in the assay mixture. The average turnover rate of aromatization of the reconstituted delta102-aromatase was 6.8 min(-1). The results of the immunosuppression assay suggested that delta102-aromatase still holds the epitope interactive to MAb3-2C2, a monoclonal antibody raised agaist human placental aromatase P450. Furthermore, the IC50 values of MAb3-2C2 were determined to be 24 and 23 microg/ml for the whole homogenate and the 105,000 x g precipitate fractions prepared from the truncated aromatase expressing cells, respectively, whereas an IC50 of 1.3 microg/ml was shown for the full-length human aromatase. These results indicate that the delta102-aromatase P450 can be expressed and is catalytically competent as the full-length enzyme, but the epitope structure for the monoclonal antibody MAb3-2C2 is altered from that of the native enzyme. In addition, the intracellular distribution of delta102-aromatase may be different from that of the wild-type enzyme, explaining why very low activity was measured using an 'In-cell' assay.  相似文献   

9.
A high-performance liquid chromatographic method was developed for the determination of a new proton pump inhibitor, YH1885 (I), in human plasma and urine, and rat blood and tissue homogenate using fenticonazole as an internal standard. The sample preparation was simple: a 2.5 volume of acetonitrile was added to the biological sample to deproteinize it. A 50-μl aliquot of the supernatant was injected onto a C8 reversed-phase column. The mobile phase employed was methanol-0.005 M tetrabutylammonium dihydrogenphosphate (77:23, v/v), and it was run at a flow-rate of 1.0 ml/min. The column effluent was monitored using an ultraviolet detector at 270 nm. The retention times for I and the internal standard were 9.0 and 10.3 min, respectively. The detection limits for I in human plasma and urine, and in rat tissue homogenate (including blood) were 50, 100 and 100 ng/ml, respectively. The coefficients of variation of the assay (within-day and between-day) were generally low (below 8.84%) for human plasma and urine, and for rat tissue homogenate. No interferences from endogenous substances were found.  相似文献   

10.
We have been studying LET and ion species dependence of RBE values in cell killing and mutation induction. Normal human skin fibroblasts were irradiated with heavy-ion beams such as carbon (290 Mev/u and 135 Mev/u), neon (230 Mev/u and 400 Mev/u), silicon (490 Mev/u) and iron (500 Mev/u) ion beams, generated by Heavy Ion Medical Accelerator in Chiba (HIMAC) at National Institute of Radiological Sciences (NIRS). Cell killing effect was detected as reproductive cell death using a colony formation assay. Mutation induction in hprt locus was detected to measure 6-thioguanine resistant colonies. The RBE-LET curves of cell killing and mutation induction were different each ion beam. So, we plotted RBE for cell killing and mutation induction as function of Z*2/beta2 instead of LET. RBE-Z*2/beta2 curves of cell killing indicated that the discrepancy of RBE-LET curves was reconciled each ion species. But RBE-Z*2/beta2 curves of mutation induction didn't corresponded between carbon- and silicon-ion beams. These results suggested that different biological endpoints may be suitable for different physical parameter, which represent the track structure of energy deposition of ion beams.  相似文献   

11.
Ogiso S  Shirai J  Tuchiya Y  Honda E 《Uirusu》2005,55(2):317-326
Antiviral assay is used routinely for measuring the biological activity of interferon (IFN). However, the challenge viruses used in these assays are considered dangerous to the animal industry and pose a risk of human infection. For example, the vesicular stomatitis virus (VSV) is an important exotic disease agent in domestic animals, and the sindbis virus provokes rash, arthralgia, and fever in humans. Therefore, biosafety needs to be considered when antiviral assays are performed. We chose Getah virus as a candidate challenge virus because it is less hazardous to animals and humans. Crystal violet staining 50% CPE inhibition antiviral assay of human IFN using Getah virus was studied. Antiviral assay using Getah virus and FL cells gave a higher titer of human IFN than did assay using VSV. The titer of human IFN alpha was almost the same as that given by standardized control samples. The titer of human IFN by antiviral assay using Getah virus on the sheet method (IFN reacted the sheeted FL cells) was higher than those of the simultaneous reaction method (IFN reacted the suspending FL cells before sheeted). We therefore consider the sheet method useful for detection of small amounts of IFN. Antiviral assay using Getah virus on MDBK cells gave a lower titer of human IFN alpha than did assay using VSV. However, the adjusting the number of MDBK cells and the titer of Getah virus to get the best condition for CPE appearance, gave similar results in the assays using Getah virus and VSV. We consider that Getah virus is a potentially useful challenge virus for antiviral assay of human IFN.  相似文献   

12.
A biological standard for beta 2 microglobulin (beta 2m) determination has been prepared from pooled human serum by sampling and freeze-drying. A preliminary study of parallelism between the dose-response curves of the preparation and pure beta 2m or biological fluids was made with four different methods of assay and gave satisfactory results. In a collaborative study in five laboratories in five countries using a common method of assay, evidence was obtained that the preparation coded 80-12-3200 was suitable to serve as a standard for the assay of beta 2 microglobulin. Criteria included the constancy of the amount of material per vial and the stability of the freeze-dried product. The technique used for beta 2m determination was a radioimmunoassay.  相似文献   

13.
Oxytocin (OT) is a neuropeptide with an extremely low endogenous level (low pg/ml) in human plasma. It is very challenging to develop a highly sensitive assay to measure endogenous OT, including radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA). Electrospray ionization (ESI) liquid chromatography–tandem mass spectrometry (LC–MS/MS) can provide high-throughput and selective methods for quantification of peptides in biological samples. A novel and highly sensitive two-dimensional LC–MS/MS (2D-LC–MS/MS) assay combining solid-phase extraction (SPE) has been developed and validated for the determination of endogenous OT in both human and rat plasma. The lower limit of quantification (LLOQ) was 1.00 pg/ml for human and 50.0 pg/ml for rat. Human plasma diluted with water (1:6, v/v) was successfully optimized as a surrogate matrix for human to prepare standard curves without endogenous interference. The extraction efficiency and absolute recovery were above 65.8% using the HLB SPE procedure, and matrix effects were lower than 12%. The method was validated in the range of 1.00–250 pg/ml for human plasma and 50.0–10,000 pg/ml for rat plasma with precision less than 12.7% and accuracy less than 7%.  相似文献   

14.
利用噬菌体展示技术筛选特异性人源抗ICAM-1单链抗体(Anti-human ICAM-1 scFv)并进行生物学活性鉴定。应用Tomlinson I+J噬菌体抗体库,以P1抗原肽为包被抗原,经过4轮“吸附-洗脱-扩增”进行亲和富集筛选。以PCR反应、ELISA抗原交叉反应和Dot blotting实验进行阳性克隆的鉴定。scFv经原核表达和分离纯化后,以Western blotting实验、竞争ELISA实验和细胞黏附抑制实验对其生物学活性进行初步鉴定。Tomlinson I+J噬菌体抗体库经4轮亲和富集筛选,利用ELISA方法成功筛出4株阳性克隆。通过PCR鉴定反应、ELISA抗原交叉反应和Dot blotting实验,最终获得了1株既能与P1抗原肽特异结合又能与人ICAM-1抗原特异结合的阳性克隆J-A1。对scFv进行原核表达和亲和层析后获得了高纯度的目的蛋白。竞争ELISA实验和细胞黏附抑制实验证实纯化的scFv具有良好的亲和活性和抗细胞黏附活性。文中成功利用噬菌体展示技术筛选到特异性人源抗ICAM-1 scFv,为进一步探索该抗体在炎症相关性疾病治疗中的应用奠定了基础。  相似文献   

15.
Thyroxine (T4), triiodothyronine (T3) and reverse triodothyronine (rT3) concentrations in human milk were measured by radioimmunoassay in 114 samples obtained from 1 week to 8 months postpartum. Several assay systems applied for the determination of serum thyroid hormone concentration were proved to be unsuitable for human milk, and the method of separating free and antibody-bound hormone by polyethylene glycol was also inappropriate for milk specimens, which tended to give a falsely high value. The binding of finity of T4 to milk was lower than that to serum protein, on which 8-anilino-1-naphthalene sulfonic acid showed no remarkable effect. In spite of the high sensitivity of 100 pg/tub in T4 assay system, no immunoassayable T4 was detected in all samples with or without ethanol extraction and trypsin hydrolysates of milk. In contrast, T3 was present in a measurable amount in most of the samples, the mean +/- SD value of which was 10 +/- 9 ng/100 ml, and those in colostrum were significantly higher than those in matured milk (P less than 0.01), whereas rT3 was not detectable in 76 samples tested. These results indicate that permeability of thyroid hormones through the mammary gland is different between T4 and T3 as well as in placental transport, and human milk can not be a source of thyroxine supply for the breast-fed infant.  相似文献   

16.
Because of the important biological functions of peroxidases, there is growing interest in the measurement of their concentrations in various secretions. At present, there is no standard method which allows for comparisons in reported activities. This report describes procedures which can be used to measure peroxidase enzyme concentrations by commonly employed assays. Regression equations have been determined which can be used to calculate concentrations of bovine lactoperoxidase (LPO), human salivary peroxidase (SPO), and human myeloperoxidase (MPO) from activities measured with the following donors: pyrogallol, guaiacol, 2,2'-azinobis(3-ethylbenzylthiazoline-6-sulfonic acid), and thiocyanate (SCN-). The peroxidation rates of these donors depend upon the concentrations of hydrogen peroxide (H2O2) used in the individual assays and thus, for accurate, reproducible results, these concentrations must be carefully controlled. The SCN- normally present in human saliva will reduce observed reaction rates by simple competition kinetics in the ABTS, guaiacol and pyrogallol assays and will increase the rates observed when Cl- is used as a donor in NBS assay for MPO. Therefore, SCN- must be removed from saliva samples prior to peroxidase activity determination by all assays except the thionitrobenzoic acid (NBS) assay. LPO cannot be used as a standard for either SPO or MPO because the specific activities of LPO, SPO, and MPO are significantly different.  相似文献   

17.
Sensitive assays for the determination of cyclobenzaprine (I) in human plasma and urine were developed utilizing high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS-MS) and ultraviolet (UV) absorbance detections. These two analytical techniques were evaluated for reliability and sensitivity, and applied to support pharmacokinetic studies. Both methods employed a liquid-liquid extraction of the compound from basified biological sample. The organic extract was evaporated to dryness ,the residue was reconstituted in the mobile phase and injected onto the HPLC system. The HPLC assay with MS-MS detection was performed on a PE Sciex API III tandem mass spectrometer using the heated nebulizer interface. Multiple reaction monitoring using the parent → daughter ion combinations of m/z 276 → 215 and 296 → 208 was used to quantitate I and internal standard (II), respectively. The HPLC-MS-MS and HPLC-UV assays were validated in human plasma in the concentration range 0.1–50 ng/ml and 0.5–50 ng/ml, respectively. In urine, both methods were validatedin the concentration range 10–1000 ng/ml. The precision of the assays, as expressed as coefficients of variation (C.V.) was less than 10% over the entire concentration range, with adequate assay specificity and accuracy. In addition to better sensitivity, the HPLC-MS-MS assay was more efficient and allowed analysis of more biological fluid samples in a single working day than the HPLC-UV method.  相似文献   

18.
Recently, we developed an improved comet assay protocol for evaluating single-strand break repair capacity (SSB-RC) in unstimulated cryopreserved human peripheral blood mononuclear cells (PBMCs). This methodology facilitates control of interexperimental variability [A.R. Trzeciak, J. Barnes, M.K. Evans, A modified alkaline comet assay for measuring DNA repair capacity in human populations. Radiat. Res. 169 (2008) 110-121]. The fast component of SSB repair (F-SSB-RC) was assessed using a novel parameter, the initial rate of DNA repair, and the widely used half-time of DNA repair. The slow component of SSB repair (S-SSB-RC) was estimated using the residual DNA damage after 60 min. We have examined repair of gamma-radiation-induced DNA damage in PBMCs from four age-matched groups of male and female whites and African-Americans between ages 30 and 64. There is an increase in F-SSB-RC with age in white females (P<0.01) and nonsignificant decrease in F-SSB-RC in African-American females (P=0.061). F-SSB-RC is lower in white females than in white males (P<0.01). There is a decrease in F-SSB-RC with age in African-American females as compared to white females (P<0.002) and African-American males (nonsignificant, P=0.059). Age, sex, and race had a similar effect on intercellular variability of DNA damage in gamma-irradiated and repairing PBMCs. Our findings suggest that age, sex, and race influence SSB-RC as measured by the alkaline comet assay. SSB-RC may be a useful clinical biomarker.  相似文献   

19.
20.
In this work the human plasma fibronectin was purified by affinity chromatography using a tandem column system. The first affinity column was filled with gelatin-Trisacryl whereas the second one contained heparin-Trisacryl. This double affinity chromatography demonstrated its high efficiency in term of purity and yield. Several analytical methods (electrophoresis, immunoelectrophoresis, F.P.L.C. and adhesion assay on cultured eucaryotic cells) evidenced in fact the high purity of the preparation as well as its biological behaviour in term of cell adhesion and spreading. The performances of the sorbents used facilitate the scaling up when large quantities of FNP are needed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号