AimThis study aimed to commission the Elekta Infinity™ working in 6 and 10 MV photon beam installed in Concord International Hospital, Singapore, and compare the OFs between MC simulation and measurement using PTW semiflex and microDiamond detector for small field sizes.Material and MethodsThere are two main steps in this study: modelling of Linac 6 and 10 MV photon beam and analysis of the output factors for field size 2 × 2–10 × 10 cm2. The EGSnrc/BEAMnrc-DOSXYZnrc code was used to model and characterize the Linac and to calculate the dose distributions in a water phantom. The dose distribution and OFs were compared to the measurement data in the same condition.ResultsThe commissioning process was only conducted for a 10 × 10 cm2 field size. The PDD obtained from MC simulation showed a good agreement with the measurement. The local dose difference of PDDs was less than 2% for 6 and 10 MV. The initial electron energy was 5.2 and 9.4 MeV for 6 and 10 MV photon beam, respectively. This Linac model can be used for dose calculation in other situations and different field sizes because this Linac has been commissioned and validated using Monte Carlo simulation. The 10 MV Linac produces higher electron contamination than that of 6 MV.ConclusionsThe Linac model in this study was acceptable. The most important result in this work comes from OFs resulted from MC calculation. This value was more significant than the OFs from measurement using semiflex and microDiamond for all beam energy and field sizes because of the CPE phenomenon.  相似文献   

2.
PurposeWe investigated the impact of transverse magnetic fields on the dose response of a nanoDot optically stimulated luminescence dosimetry (OSLD) in megavoltage photon beams.MethodsThe nanoDot OSLD response was calculated via Monte Carlo (MC) simulations. The responses RQ and RQ,B without and with the transverse magnetic fields of 0.35–3 T were analyzed as a function of depth at a 10 cm × 10 cm field for 4–18 MV photons in a solid water phantom. All responses were determined based on comparisons with the response under the reference conditions (depth of 10 cm and a 10 cm × 10 cm field) for 6 MV without the magnetic field. In addition, the influence of air-gaps on the nanoDot response in the magnetic field was estimated according to Burlin’s general cavity theory.ResultsThe RQ as a function of depth for 4–18 MV ranged from 1.013 to 0.993, excepting the buildup region. The RQ,B increased from 2.8% to 1.5% at 1.5 T and decreased from 3.0% to 1.1% at 3 T in comparison with RQ as the photon energy increased. The depth dependence of RQ,B was less than 1%, excepting the buildup region. The top air-gap and the bottom air- gap were responsible for the response reduction and the response increase, respectively.ConclusionsThe response RQ,B varied depending on the magnetic field intensity, and the variation of RQ,B reduced as the photon beam energy increased. The air-gaps affected the dose deposition in the magnetic fields.  相似文献   

3.

Aim

The aim of this study was to compare two bunkers designed by only protocols recommendations and Monte Carlo (MC) based upon data derived for an 18 MV Varian 2100Clinac accelerator.

Background

High energy radiation therapy is associated with fast and thermal photoneutrons. Adequate shielding against the contaminant neutron has been recommended by IAEA and NCRP new protocols.

Materials and methods

The latest protocols released by the IAEA (safety report No. 47) and NCRP report No. 151 were used for the bunker designing calculations. MC method based upon data was also derived. Two bunkers using protocols and MC upon data were designed and discussed.

Results

From designed door''s thickness, the door designed by the MC simulation and Wu–McGinley analytical method was closer in both BPE and lead thickness. In the case of the primary and secondary barriers, MC simulation resulted in 440.11 mm for the ordinary concrete, total concrete thickness of 1709 mm was required. Calculating the same parameters value with the recommended analytical methods resulted in 1762 mm for the required thickness using 445 mm as recommended by TVL for the concrete. Additionally, for the secondary barrier the thickness of 752.05 mm was obtained.

Conclusion

Our results showed MC simulation and the followed protocols recommendations in dose calculation are in good agreement in the radiation contamination dose calculation. Difference between the two analytical and MC simulation methods revealed that the application of only one method for the bunker design may lead to underestimation or overestimation in dose and shielding calculations.  相似文献   

4.
5.
BackgroundAccumulated evidence suggests a weak positive relationship between psychosocial stress and body mass index (BMI), but little is known about stress coping strategies and BMI.ObjectiveWe aimed to examine if perceived stress and coping strategies are related to BMI, with any of their mutual interactions on BMI.MethodsThis cross-sectional study included 5,063 men and 6,982 women aged 40-69 years. A self-administered questionnaire ascertained perceived stress and 5 items of coping strategies (emotion expression, emotional support seeking, positive reappraisal, problem solving, and disengagement). Analyses were performed by gender with adjustment for age, socioeconomic status, and lifestyle factors.ResultsNo significant associations were detected between perceived stress and BMI in either men (Ptrend = 0.09) or women (Ptrend = 0.58). In men, however, ‘disengagement’ showed an inverse association with BMI (Ptrend < 0.001), and ‘positive reappraisal’ and ‘problem solving’ revealed a positive association with BMI (Ptrend = 0.04 and 0.007, respectively) even after controlling for perceived stress. A possible interaction between perceived stress and ‘disengagement’ on BMI was found in men (Pinteraction = 0.027); the inverse association between ‘disengagement’ and BMI was more evident in higher levels of stress (β = −0.13, Ptrend = 0.21 in low; β = −0.22, Ptrend = 0.01 in medium; and β = −0.24, Ptrend = 0.06 in high). In men, ‘disengagement’ was inversely associated with overweight/obesity (odds ratio 0.79, 95% confidential interval 0.67-0.95), and “positive reappraisal” was positively associated with it (1.25, 1.02-1.54).ConclusionsCoping strategies may have an important role in developing overweight/obesity, particularly in men.  相似文献   

6.
Understanding rooting dynamics using the minirhizotron technique is useful for cultivar selection and to quantify nematode damage to roots. A 2-yr microplot study including five bermudagrass (‘Tifway’, Belonolaimus longicaudatus susceptible; two commercial cultivars [TifSport and Celebration] and two genotypes [‘BA132’ and ‘PI 291590’], which have been reported to be tolerant to B. longicaudatus) and two St. Augustinegrass (‘FX 313’, susceptible, and ‘Floratam’ that was reported as tolerant to B. longicaudatus) genotypes in a 5 x 2 and 2 x 2 factorial design with four replications, respectively, was initiated in 2012. Two treatments included were uninoculated and B. longicaudatus inoculated. In situ root images were captured each month using a minirhizotron camera system from April to September of 2013 and 2014. Mixed models analysis and comparison of least squares means indicated significant differences in root parameters studied across the genotypes and soil depths of both grass species. ‘Celebration’, ‘TifSport’ and ‘PI 291590’ bermudagrass, and ‘Floratam’ St. Augustinegrass had significantly different root parameters compared to the corresponding susceptible genotypes (P ≤ 0.05). Only ‘TifSport’ had no significant root loss when infested with B. longicaudatus compared to non-infested. ‘Celebration’ and ‘PI 291590’ had significant root loss but retained significantly greater root densities than ‘Tifway’ in B. longicaudatus-infested conditions (P ≤ 0.05). Root lengths were greater at the 0 to 5 cm depth followed by 5 to 10 and 10 to 15 cm of vertical soil depth for both grass species (P ≤ 0.05). ‘Celebration’, ‘TifSport’, and ‘PI 291590’ had better root vigor against B. longicaudatus compared to Tifway.  相似文献   

7.

Background and Aims

Although ammonium (NH4+) is the preferred form of nitrogen over nitrate (NO3) for rice (Oryza sativa), lateral root (LR) growth in roots is enhanced by partial NO3 nutrition (PNN). The roles of auxin distribution and polar transport in LR formation in response to localized NO3 availability are not known.

Methods

Time-course studies in a split-root experimental system were used to investigate LR development patterns, auxin distribution, polar auxin transport and expression of auxin transporter genes in LR zones in response to localized PNN in ‘Nanguang’ and ‘Elio’ rice cultivars, which show high and low responsiveness to NO3, respectively. Patterns of auxin distribution and the effects of polar auxin transport inhibitors were also examined in DR5::GUS transgenic plants.

Key Results

Initiation of LRs was enhanced by PNN after 7 d cultivation in ‘Nanguang’ but not in ‘Elio’. Auxin concentration in the roots of ‘Nanguang’ increased by approx. 24 % after 5 d cultivation with PNN compared with NH4+ as the sole nitrogen source, but no difference was observed in ‘Elio’. More auxin flux into the LR zone in ‘Nanguang’ roots was observed in response to NO3 compared with NH4+ treatment. A greater number of auxin influx and efflux transporter genes showed increased expression in the LR zone in response to PNN in ‘Nanguang’ than in ‘Elio’.

Conclusions

The results indicate that higher NO3 responsiveness is associated with greater auxin accumulation in the LR zone and is strongly related to a higher rate of LR initiation in the cultivar ‘Nanguang’.  相似文献   

8.
PurposeMonte Carlo (MC) is the reference computation method for medical physics. In radiotherapy, MC computations are necessary for some issues (such as assessing figures of merit, double checks, and dose conversions). A tool based on GATE is proposed to easily create full MC simulations of the Varian TrueBeam STx.MethodsGAMMORA is a package that contains photon phase spaces as a pre-trained generative adversarial network (GAN) and the TrueBeam’s full geometry. It allows users to easily create MC simulations for simple or complex radiotherapy plans such as VMAT. To validate the model, the characteristics of generated photons are first compared to those provided by Varian (IAEA format). Simulated data are also compared to measurements in water and heterogeneous media. Simulations of 8 SBRT plans are compared to measurements (in a phantom). Two examples of applications (a second check and interplay effect assessment) are presented.ResultsThe simulated photons generated by the GAN have the same characteristics (energy, position, and direction) as the IAEA data. Computed dose distributions of simple cases (in water) and complex plans delivered in a phantom are compared to measurements, and the Gamma index (3%/3mm) was always superior to 98%. The feasibility of both clinical applications is shown.ConclusionsThis model is now shared as a free and open-source tool that generates radiotherapy MC simulations. It has been validated and used for five years. Several applications can be envisaged for research and clinical purposes.  相似文献   

9.
PurposeDosimetry of fast, epithermal and thermal photoneutrons in 6 MV X-ray beams of two medical accelerators were studied by novel dosimetry methods.MethodsA Siemens ONCOR and an Elekta COMPACT medical accelerators were used. Fast, epithermal and thermal photoneutron dose equivalents in 10 cm × 10 cm 6 MV X-rays fields were determined in air and on surface of a polyethylene phantom in X and Y directions. Polycarbonate dosimeters as bare or with enriched 10B convertors (with or without cadmium covers) were used applying a 50 Hz-HV electrochemical etching method.ResultsFast, epithermal and thermal photoneutron dose equivalents were efficiently determined respectively as ∼1145.8, ∼45.3 and ∼170.6 μSv in air and ∼1888.5, ∼96.1 and ∼640.6 μSv on phantom per 100 Gy X-rays at the isocenter of Siemens ONCOR accelerator in air. The dose equivalent is maximum at the isocenter which decreases as distance from it increases reaching a constant level. Tissue-to-air ratios are constants up to 15 cm from the isocenter. No photoneutrons was detected in the Elekta COMPACT accelerator.ConclusionsFast, epithermal and thermal photoneutron dosimetry of 6 MV X-rays were made by novel dosimetry methods in a Siemens ONCOR accelerator with sum dose equivalent per Gy of ∼0.0014% μSv with ∼0.21 MeV mean energy at the isocenter; i.e. ∼150 times smaller than that of 18 MV X-rays. This observation assures clinical safety of 6 MV X-rays in particular in single-mode machines like Elekta COMPACT producing no photoneutrons due to no “beryllium exit window” in the head structure.  相似文献   

10.
Background3-dimensional intra-cone beam computed tomography (intra-CBCT ) could be a potentially powerful tool for use with arc irradiation such as volumetric modulated arc therapy. The aim of the study was to evaluate the image quality of intra-cone beam computed tomography (intra-CBCT ) for arc irradiation with various imaging condition.Materials and methodsTwo types of intra-CBCT imaging techniques were evaluated — intra-fractional CBCT with flattening filtered (FF) beam (intra-FF CBCT ) and that with flattening filter free (FFF) beam (intra-FFF CBCT ). For the intra-MV beams, four different field sizes (2 cm × 2 cm, 5 cm × 5 cm, 10 cm × 10 cm, and 20 cm × 20 cm) were used with dose rates of 500 MU/min and 1600 MU/min, for 6 MV FF and 6 MV FFF, respectively. For all image acquisitions, two rotation angles (full-arc and half-arc) were investigated. Thereafter, the linearity, contrast-to-noise ratio (CNR), and uniformity index (UI) of intra-CBCT image were compared with those of conventional CBCT image.ResultsAll acquisition conditions had good linearity of the CT value (R2 > 0.99). For CNR, the change rates from conventional CBCT ranged from 0.6–33.7% for a 2 cm × 2 cm beam, whereas that for a 20 cm × 20 cm beam ranged from 62.7–82.3%. Similarly, the UI increased from 1.5% to 7.0% as the field size increased.ConclusionQuality of intra-CBCT image was affected by the field size and acquisition angle. Image quality of intra-CBCT was worse than that of conventional CBCT, but it was better under a smaller field and wider correction angle and would be acceptable for clinical use.  相似文献   

11.
Melanocortin 4 receptor (MC4R), which is associated with inherited human obesity, is involoved in food intake and body weight of mammals. To study the relationships between MC4R gene polymorphism and body weight in Beagle dogs, we detected and compared the nucleotide sequence of the whole coding region and 3′- and 5′- flanking regions of the dog MC4R gene (1214 bp). In 120 Beagle dogs, two SNPs (A420C, C895T) were identified and their relation with body weight was analyzed with RFLP-PCR method. The results showed that the SNP at A420C was significantly associated with canine body weight trait when it changed amino acid 101 of the MC4R protein from asparagine to threonine,while canine body weight variations were significant in female dogs when MC4R nonsense mutation at C895T. It suggested that the two SNPs might affect the MC4R gene’s function which was relative to body weight in Beagle dogs. Therefore, MC4R was a candidate gene for selecting different size dogs with the MC4R SNPs (A420C, C895T) being potentially valuable as a genetic marker.  相似文献   

12.
The present investigation was targeted towards a highly desirable everbearing trait in strawberry (Fragaria × ananassa Duch.) via marker assisted selection while seeing its worldwide commercial applicability through the extended harvest season. The crosses were made between everbearing and june-bearing cultivars to raise the F1 individuals. Morphological characters (plant, floral, and fruit) were assessed that showed significant differences among the strawberry cultivars. Molecular characterization was carried out between everbearing and non-everbearing cultivars using RAPD and SSR markers. For phenotyping, a chi-square test was performed and revealed that out of all four cross combinations, the best fitted cross found to be in Mendelian segregation ratio (1:1) was ‘Confectura’ × ‘Torrey’ with χ2-value 1.58. Further, the identified polymorphic markers were assessed across the F1 individuals of cross ‘Confectura’ × ‘Torrey’ for its genotyping. It could be revealed that the targeted everbearing trait is governed by a dominant gene(s) in the subjected strawberry genotypes. Further, the identified polymorphic markers would be successfully employed in DNA fingerprinting of strawberry under various crop improvement programme.Supplementary informationThe online version of this article (10.1007/s12298-020-00916-w) contains supplementary material, which is available to authorized users.  相似文献   

13.

Aim

To measure and compare the head scatter factor for 7 MV unflattened and 6 MV flattened photon beam using a home-made designed mini phantom.

Background

The head scatter factor (Sc) is one of the important parameters for MU calculation. There are multiple factors that influence the Sc values, like accelerator head, flattening filter, primary and secondary collimators.

Materials and methods

A columnar mini phantom was designed as recommended by AAPM Task Group 74 with high and low atomic number material for measurement of head scatter factors at 10 cm and dmax dose water equivalent thickness.

Results

The Sc values measured with high-Z are higher than the low-Z mini phantoms observed for both 6MV-FB and 7MV-UFB photon energies. Sc values of 7MV-UFB photon beams were smaller than those of the 6MV-FB photon beams (0.6–2.2% (Primus), 0.2–1.4% (Artiste) and 0.6–3.7% (Clinac iX (2300CD))) for field sizes ranging from 10 cm × 10 cm to 40 cm × 40 cm. The SSD had no influence on head scatter for both flattened and unflattened beams. The presence of wedge filters influences the Sc values. The collimator exchange effects showed that the opening of the upper jaw increases Sc irrespective of FF and FFF.

Conclusions

There were significant differences in Sc values measured for 6MV-FB and unflattened 7MV-UFB photon beams over the range of field sizes from 10 cm × 10 cm to 40 cm × 04 cm. Different results were obtained for measurements performed with low-Z and high-Z mini phantoms.  相似文献   

14.

Aim

To compare and evaluate the performance of two different volumetric modulated arc therapy delivery techniques.

Background

Volumetric modulated arc therapy is a novel technique that has recently been made available for clinical use. Planning and dosimetric comparison study was done for Elekta VMAT and Varian RapidArc for different treatment sites.

Materials and methods

Ten patients were selected for the planning comparison study. This includes 2 head and neck, 2 oesophagus, 1 bladder, 3 cervix and 2 rectum cases. Total dose of 50 Gy was given for all the plans. All plans were done for RapidArc using Eclipse and for Elekta VMAT with Monaco treatment planning system. All plans were generated with 6 MV X-rays for both RapidArc and Elekta VMAT. Plans were evaluated based on the ability to meet the dose volume histogram, dose homogeneity index, radiation conformity index, estimated radiation delivery time, integral dose and monitor units needed to deliver the prescribed dose.

Results

RapidArc plans achieved the best conformity (CI95% = 1.08 ± 0.07) while Elekta VMAT plans were slightly inferior (CI95% = 1.10 ± 0.05). The in-homogeneity in the PTV was highest with Elekta VMAT with HI equal to 0.12 ± 0.02 Gy when compared to RapidArc with 0.08 ± 0.03. Significant changes were observed between the RapidArc and Elekta VMAT plans in terms of the healthy tissue mean dose and integral dose. Elekta VMAT plans show a reduction in the healthy tissue mean dose (6.92 ± 2.90) Gy when compared to RapidArc (7.83 ± 3.31) Gy. The integral dose is found to be inferior with Elekta VMAT (11.50 ± 6.49) × 104 Gy cm3 when compared to RapidArc (13.11 ± 7.52) × 104 Gy cm3. Both Varian RapidArc and Elekta VMAT respected the planning objective for all organs at risk. Gamma analysis result for the pre-treatment quality assurance shows good agreement between the planned and delivered fluence for 3 mm DTA, 3% DD for all the evaluated points inside the PTV, for both VMAT and RapidArc techniques.

Conclusion

The study concludes that a variable gantry speed with variable dose rate is important for efficient arc therapy delivery. RapidArc presents a slight improvement in the OAR sparing with better target coverage when compared to Elekta VMAT. Trivial differences were noted in all the plans for organ at risk but the two techniques provided satisfactory conformal avoidance and conformation.  相似文献   

15.
16.
‘Jin Zhui’ is a spontaneous self-compatible mutant of ‘Ya Li’ (Pyrus bretschneideri Rehd. S21S34), the latter displaying a typical S-RNase-based gametophytic self-incompatibility (GSI). The pollen-part mutation (PPM) of ‘Jin Zhui’ might be due to a natural mutation in the pollen-S gene (S34 haplotype). However, the molecular mechanisms behind these phenotypic changes are still unclear. In this study, we identified five SLF (S-Locus F-box) genes in ‘Ya Li’, while no nucleotide differences were found in the SLF genes of ‘Jin Zhui’. Further genetic analysis by S-RNase PCR-typing of selfed progeny of ‘Jin Zhui’ and ‘Ya Li’ × ‘Jin Zhui’ progeny showed three progeny classes (S21S21, S21S34 and S34S34) as opposed to the two classes reported previously (S21S34 and S34S34), indicating that the pollen gametes of ‘Jin Zhui’, bearing either the S21- or S34-haplotype, were able to overcome self-incompatibility (SI) barriers. Moreover, no evidence of pollen-S duplication was found. These findings support the hypothesis that loss of function of S-locus unlinked PPM expressed in pollen leads to SI breakdown in ‘Jin Zhui’, rather than natural mutation in the pollen-S gene (S34 haplotype). Furthermore, abnormal meiosis was observed in a number of pollen mother cells (PMCs) in ‘Jin Zhui’, but not in ‘Ya Li’. These and other interesting findings are discussed.  相似文献   

17.
PurposeThis study aims to use GATE/Geant4 simulation code to evaluate the performance of dose calculations with Anisotropic Analytical Algorithm (AAA) in the context of lung SBRT for complex treatments considering images of patients.MethodsFour cases of non-small cell lung cancer treated with SBRT were selected for this study. Irradiation plans were created with AAA and recalculated end to end using Monte Carlo (MC) method maintaining field configurations identical to the original plans. Each treatment plan was evaluated in terms of PTV and organs at risk (OARs) using dose-volume histograms (DVH). Dosimetric parameters obtained from DVHs were used to compare AAA and MC.ResultsThe comparison between the AAA and MC DVH using gamma analysis with the passing criteria of 3%/3% showed an average passing rate of more than 90% for the PTV structure and 97% for the OARs. Tightening the criteria to 2%/2% showed a reduction in the average passing rate of the PTV to 86%. The agreement between the AAA and MC dose calculations for PTV dosimetric parameters (V100; V90; Homogeneity index; maximum, minimum and mean dose; CIPaddick and D2cm) was within 18.4%. For OARs, the biggest differences were observed in the spinal cord and the great vessels.ConclusionsIn general, we did not find significant differences between AAA and MC. The results indicate that AAA could be used in complex SBRT cases that involve a larger number of small treatment fields in the presence of tissue heterogeneities.  相似文献   

18.
19.
PurposeMonte Carlo (MC) simulations are highly desirable for dose treatment planning and evaluation in radiation oncology. This is true also in emerging nuclear medicine applications such as internal radiotherapy with radionuclides. The purpose of this study is the validation of irtGPUMCD, a GPU-based MC code for dose calculations in internal radiotherapy.MethodsThe female and male phantoms of the International Commission on Radiological Protection (ICRP 110) were used as benchmarking geometries for this study focused on 177Lu and including 99mTc and 131I. Dose calculations were also conducted for a real patient. For phantoms, twelve anatomical structures were considered as target/source organs. The S-values were evaluated with irtGPUMCD simulations (108 photons), with gamma branching ratios of ICRP 107 publication. The 177Lu electrons S-values were calculated for source organs only, based on local deposition of dose in irtGPUMCD. The S-value relative difference between irtGPUMCD and IDAC-DOSE were evaluated for all targets/sources considered. A DVHs comparison with GATE was conducted. An exponential track length estimator was introduced in irtGPUMCD to increase computational efficiency.ResultsThe relative S-value differences between irtGPUMCD and IDAC-DOSE were <5% while this comparison with GATE was <1%. The DVHs dosimetric indices comparison between GATE and irtGPUMCD for the patient led to an excellent agreement (<2%). The time required for the simulation of 108 photons was 1.5 min for the female phantom, and one minute for the real patient (<1% uncertainty). These results are promising and let envision the use of irtGPUMCD for internal dosimetry in clinical applications.  相似文献   

20.
BackgroundThe aim of the study was to Estimate and compare the radiobiological ratio α/β with the heuristic method for a cohort of Mexican patients with prostate cancer (PCa) who were treated with external radiotherapy (RT) techniques at three Hospital Institutions in Mexico City. With the Kaplan-Meier technique and the Cox proportional hazards model, the biochemical relapse-free survival (bRFS) is determined and characterized for cohorts of Mexican patients with PCa who received treatment with external RT. Using these clinical outcomes, the radiobiological parameter α/β is determined using the heuristic methodology of Pedicini et. al.Materials and methodsThe α/β is calculated from the survival curves for different treatment schemes implemented at three distinct hospitals. The Pedicini’s techniques allow to determine the parameters α/β, k and N0 when treatments are not radiobiologically equivalent, therefore, are built up of a set of curved pairs for the biologically effective dose (BED) versus the ratio α/β, where the ratio is given by the intersection for each pair of curves.ResultsSix different values of α/β were found: the first α/β = 2.46 Gy, the second α/β = 3.30 Gy, the third for α/β = 3.25 Gy, the fourth α/β = 3.24 Gy, the fifth α/β = 3.38 Gy and the last α/β = 4.08 Gy. These values can be explained as follows: a) The bRFS of the schemes presents a statistical variation; b) The absorbed doses given to the patient present uncertainties on the physical dosimetry that are not on the modeling; c) Finally, in the model for the bRFS of Eq. (3), there are parameters that have to be considered, such as: the number of clonogenic tumor cells N0, the overall treatment time (OTT), the kick-off time for tumor repopulation Tk and the repopulation doubling time. Therefore, the mean value to α/β for all schemes has an average value of 3.29 (± 0.52) Gy.ConclusionsThe value of α/β¯=3.29(±0.52)Gy is determined from cohorts of Mexican patients with PC a treated with external radiotherapy using the time-dependent LQ model, which is a higher value with respect to the “dogma” value of α/β 1.5 Gy obtained with the LQ model without temporal dependence. Therefore, there is a possibility of optimizing treatments radiobiologically and improving the results of bRFS in Mexican patients with PCa treated with external radiotherapy.  相似文献   