首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
PurposeA retrospective planning study was undertaken to evaluate the dosimetric advantages of the irregular surface compensator (ISC) technique, a forward planning technique with electronic compensation algorithm available on Varian Eclipse treatment planning system. This was extensively compared to the conventional four-field box (4FB) and intensity modulated radiation therapy using 5 fields (IMRT5F) on gynecologic cancer patients.MethodsTwenty-two patients were enrolled. The prescribed dose was 50.4 Gy in 28 fractions to the primary target including pelvic lymph nodes. 4FB treatment plans were generated, then fluence of anterior and posterior fields were modified to generate ISC plans. IMRT5F were inversely optimized with equally spaced five coplanar fields. Dose-volume parameters were evaluated for the comparison of three planning techniques. The MU and delivery time were also estimated.ResultsIn terms of target coverage, the conformity and homogeneity index of ISC (1.67 and 1.03, respectively) were superior to those of 4FB (2.43 and 1.06, respectively) but slightly inferior to those of IMRT5F (1.10 and 1.02, respectively). ISC also illustrated an overall improvement in normal organ saving. Compared to 4FB, the mean dose of the rectum was reduced by about 4.0–5.0 Gy with ISC and IMRT5F. The volume receiving large doses was reduced for bladder with statistical significance with ISC and more with IMRT5F relative to 4FB. The mean number of MU per fraction were 200.86 (4FB), 446.09 (ISC) and 895.59 (IMRT5F).ConclusionThe ISC technique has the superior target coverage and healthy tissue sparing in comparison with conventional 4FB and comparable normal organ saving compared to IMRT5F. The ISC can be an available option for gynecologic radiotherapy.  相似文献   

2.
BackgroundSetup accuracy within adjuvant radiotherapy of breast cancer treated in free breathing is well studied, but a comparison of the typical regions of interest (ROI) used in surface guided radiation therapy (SGRT) does not exist. The aim of this study was to estimate the setup accuracy obtained with differently shaped ROIs in SGRT.Materials and methodsA total of 573 orthogonal image pairs were analyzed from free breathing breast patients in two groups: positioning using AlignRT® surface guidance system (Group A, n = 20), and setup using conventional laser and tattoo setup (Group L, n = 20). For SGRT, three different setup ROIs were used: a Breast-shaped, O-shaped and T-shaped (B-O and T-ROI). We evaluated the isocenter-, rotation-, pitch and arm position accuracy and residual errors for the chest wall and shoulder joint in kV orthogonal and tangential setup images with laser- or SGRT-based setup.ResultsLess isocenter variance was found in Group A than in Group L. Rotations and posture errors were larger in group L than in Group A (p ≤ 0.05). Rotation error was smaller with T-shaped ROI than with O- or B-shape (p = 0.01–0.04).ConclusionSetup with AlignRT® improves reproducibility compared to laser setup. Between the different ROI shapes only small differences were found in the patient posture or the isocenter position in the images. The T-ROI is recommended to set up the chest wall bony structure and an additional B-ROI may be used to fine-tune the soft tissue accuracy.  相似文献   

3.
BackgroundModerately post-operative hypofractionated radiotherapy (HYPO-RT) for breast cancer is a safe and effective strategy as seen in large prospective trials. This study aimed to assess overall and disease-free survivals, local control, and acute and late toxicities in patients treated with HYPO-RT.Materials and methodsData from patients submitted to post-operative HYPO-RT, with or without boost, were evaluated retrospectively. Demographic, disease, and treatment characteristics were collected.ResultsFrom March 2009 to December 2016, 393 patients were treated. Breast-conserving surgery was performed in 94.7%, immediate reconstruction after mastectomy in 6 (1.5%). Most patients (91.2%) had initial stage (0 to IIA), and chemotherapy was performed in 42.0%, HYPO-RT was mainly performed in 15 or 16 daily fractions of 267 cGy and 265 cGy, respectively. The median follow-up was 5.7 years. There were 25 deaths (6.4%) and 17 (4.3%) local recurrences. At 5 and 10 years, the overall survival, local control, and disease-free survival were, respectively, 96.0% and 79.3%, 99.2% and 94.9%, 96.6%, and 91.9%. Acute grade 3 or 4 dermatitis was observed in 0.9%. Late grade 1 or 2 occurred in less than 3% of the patients.ConclusionHYPO-RT is a safe and effective radiotherapy regimen with excellent disease control and overall survival rates, with low acute and late toxicity rates.  相似文献   

4.
5.
BackgroundThe aim of the study was to individualize accelerated partial breast irradiation based on optimal dose distribution, protect risk organ and predict most advantageous technique.Materials and methods138 breast cancer patients receiving postoperative APBI were enrolled. APBI plans were generated using 3D-conformal (3D-CRT), sliding window intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT). In the case of superficial tumours, additional plans were developed by adding electron beam. To planning target volume (PTV) 37.5 Gy/10 fractions, 1 fraction/day was prescribed. A novel plan quality index (PQI) served as the basis for comparisons.ResultsIMRT was the most advantageous technique regarding homogeneity. VMAT provided best conformity, 3D-CR T — the lowest lung and heart exposure. PQI was the best in 45 (32.61%) VMAT, 13 (9.42%) IMRT, 9 (6.52%) 3D-CRT plans. In 71 cases (51.45%) no difference was detected. In patients with large PTV, 3D-CRT was the most favourable. Additional electron beam improved PQI of 3D-CRT plans but had no meaningful effect on IMRT or VMAT. IMRT was superior to VMAT if the tumour was superficial (p < 0.001), situated in the medial (p = 0.032) or upper quadrant (p = 0.046).ConclusionsIn half of all cases, individually selected teletherapy techniques provide superior results over others; relevance of a certain technique may be predicted by volume and PTV localization.  相似文献   

6.
BackgroundBrain metastases (BM) occur in almost one third of patients with systemic malignancies. Only a small number of studies focus on infratentorial location and whole brain radiotherapy (WBRT) as the main non-surgical management. The aim of the study was to compare the prognosis of patients treated with WBRT among patients with supra- or infratentorial lesions.Materials and methodsAt a single center, 263 patients with either breast (BC) or lung (LC) cancer, that had developed BM and received treatment with WBRT, were analyzed during an 8-year period.ResultsA total of 152 patients with BC and 111 with LC were analyzed, median age at the time of BM was 50.7 years, systemic activity other than BM was detected in 91%. Newly diagnosed BM were supratentorial in 40%, infratentorial in 10% and 51% in both locations. Median overall survival was 13 months (95% CI: 11.1–14.8 months), without significant difference between supra- or infratentorial location. WBRT alone was administered in 79% of patients, whereas WBRT with chemtoreapy was provided for 21%.ConclusionIn patients with BM from LC or BC that were not candidates for surgical resection, palliative WBRT appears to be equally effective in those with supra- or infratentorial locations.  相似文献   

7.
PurposeQuality assurance (QA) is one of the most important issues that should be addressed for intraoperative electron radiotherapy (IOERT), which is not benefiting from image-based treatment planning system. The aim of this study is to evaluate the dosimetric characteristics of Gafchromic EBT2 film for breast IOERT QA procedure.MethodsDue to the fact that some dedicated accelerators are being used for IOERT, dependence of the film response to energy, field size, dose rate and incidence angle of electron beam from the LIAC IOERT accelerator was studied. Then, film response curve to breast IOERT doses was obtained and its accuracy was evaluated and justified through comparison to the results of ionometric dosimetry.ResultsThe results of this study indicated that there are no significant differences between the film responses at different energies of 6, 8, 10 and 12 MeV (P-value = 0.99). Similarly, no field size dependency was found when evaluating the response of the film to different field sizes ranging from 4 to 10 cm (P-value = 0.94). Film response was found to be independent of the dose rate of intraoperative electron beam (P-value = 0.12). Film response variations with changing the beam incidence angle were not significant (P-value > 0.8). Calibration curve at the dose range of 8–24 Gy had an acceptable accuracy. The difference between the results of film dosimetry and ionometric dosimetry was around 5% which was in agreement with the results of dose uncertainty estimation.ConclusionThe EBT2 film was found to be a potentially appropriate tool for breast IOERT verification.  相似文献   

8.
Background and purposeTo assess anatomic changes during intensity modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC) and to determine its dosimetric impact.Patients and methodsTwenty patients treated with IMRT for NPC were enrolled in this study. A second CT was performed at 38 Gy. Manual contouring of the macroscopic tumor volumes (GTV) and the planning target volumes (PTV) were done on the second CT. We recorded the volumes of the different structures, D98 %, the conformity, and the homogeneity indexes for each PTV. Volume percent changes were calculated.ResultsWe observed a significant reduction in tumor volumes (58.56 % for the GTV N and 29.52 % for the GTV T). It was accompanied by a significant decrease in the D98 % for the 3 PTV (1.4 Gy for PTV H, p = 0.007; 0.3 Gy for PTV I, p = 0.03 and 1.15 Gy for PTV L, p = 0 0.0066). In addition, we observed a significant reduction in the conformity index in the order of 0.02 (p = 0.001) and 0.01 (p = 0.007) for PTV H and PTV I, respectively. The conformity variation was not significant for PTV L. Moreover, results showed a significant increase of the homogeneity index for PTV H (+ 0.03, p = 0.04) and PTV L (+ 0.04, p = 0.01).ConclusionTumor volume reduction during the IMRT of NPC was accompanied by deterioration of the dosimetric coverage for the different target volumes. It is essential that a careful adaptation of the treatment plan be considered during therapy for selected patients.  相似文献   

9.

Aim

In this study, we intend to compare two different setup procedures for female breast cancer patients.

Background

Imaging in radiotherapy provides a precise localization of the tumour, increasing the accuracy of the treatment delivery in breast cancer.

Materials and methods

Twenty breast cancer patients who underwent whole breast radiotherapy (WBRT) were selected for this study. Patients were divided into two groups of ten. Group one (G1) was positioned by tattoos and then the patient positioning was adjusted with the aid of AlignRT (Vision RT, London, UK). In group two (G2), patients were positioned only by tattoos. For both groups, the first 15 fractions were analyzed, a daily kilovoltage (kV) cone beam computed tomography (CBCT) image was made and then the rotational and translational displacements and, posteriorly, the systematic (Σ) and random (σ) errors were analyzed.

Results

The comparison of CBCT displacements for the two groups showed a statistically significant difference in the translational left–right (LR) direction (ρ = 0.03), considering that the procedure with AlignRT system has smaller lateral displacements. The results of systematic (Σ) and random (σ) errors showed that for translational displacements the group positioned only by tattoos (G2) demonstrated higher values of errors when compared with the group positioned with the aid of AlignRT (G1).

Conclusions

AlignRT could help the positioning of breast cancer patients; however, it should be used with another imaging method.  相似文献   

10.
BackgroundThe aim of this study was to investigate the recurrence patterns in pancreatic cancer patients treated with adjuvant intensity modulated radiotherapy (IMRT) and to correlate the sites of locoregional recurrence with radiotherapy target volumes.Materials and methodsThirty-eight patients who had undergone resection and adjuvant chemoradiation for pancreatic cancer were evaluated. Radiotherapy (RT) was started after 1–3 cycles of adjuvant chemotherapy (CHT). Clinical target volume (CTV) was contoured according to the RTOG guideline. All patients were treated with IMRT with a dose of 45–50.4 Gy. Computerized tomography (CT) images at the time of recurrence were correlated with radiotherapy plans. Locoregional recurrences were classified as in-field, out-field and marginal.ResultsMedian overall survival (OS) was 19 months. One- and 2-year OS rates were 73.6% and 37.1%, respectively. Locoregional recurrence and distant metastases were observed in 11 (28.9%) and 23 (60.5%) patients, respectively. For the 11 locoregional recurrences, 7 were in-field, 1 was marginal, and 3 were out-of-field. One patient had isolated local, 2 patients had isolated regional and 15 (57.6%) patients had only distant failures. The first presentations of failures were mostly distant (58%). On multivariate analysis, tumor size ≥ 3 cm (p = 0.011) and positive vascular invasion (p = 0.014) predicted for worse OS rate.ConclusionsThe majority of locoregional recurrences were in the radiation field among pancreatic cancer patients treated with postoperative IMRT. However, failures were predominantly distant, and improvement of systemic control may be of particular interest.  相似文献   

11.
BackgroundThe aim of our study is to determine whether deep inspiration breath hold (DIBH) is effective for reducing exposure of the heart, left coronary artery (LAD) and both lungs in right breast radiotherapy.Materials and methodsWe have analyzed 10 consecutive patients with right-sided breast cancer (BC), simulated during free breathing (FB) and in DIBH modality. For all patients we contoured breast PTV and organs at risk (right and left lungs, heart, LAD) on both CT scans (FB and DIBH). Finally, 5 patients were treated with IMRT and 5 with VMAT techniques.ResultsAll patients were able to end the treatments in DIBH modalities regardless of the longer treatment time in comparison to FB. The maximum and mean dose to the heart are lower in the DIBH modality. The mean values of the heart mean dose were 1.76 Gy in DIBH and 2.19 Gy in FB. The mean heart maximum dose in DIBH and FB were, respectively, 9.3 Gy and 11 Gy. Likewise, the maximum dose to the LAD is lower in DIBH; 2.57 Gy versus 3.56 Gy in FB. Noteworthy, 3 patients with hepatomegaly treated with the DIBH technique showed a higher ipsilateral lung dose than FB, but a decrease of liver dose.ConclusionWe report that the use of DIBH for right-sided BC allows the dose to the heart, LAD and to the liver to be reduced in case of hepatomegaly. This technique is well tolerated by patients, when adequately trained, and could be considered effective even in right sided BC.  相似文献   

12.

Background

Accelerated partial breast irradiation (APBI) is a promising method of adjuvant radiotherapy for select patients. Intraoperative radiotherapy (IORT) is a form of APBI, and appropriate patient selection is important.

Aim

The aim of our study was to analyse the influence of our protocol on the frequency of WBRT after IORT and our protocol's correlation with the reported use of WBRT according to TARGIT guidelines. We also aimed to verify how changes in our protocol influenced the frequency of WBRT.

Material and methods

Between April 20, 2010 and May 10, 2017, we identified 207 patients irradiated with IORT for APBI.

Results

Ninety-one patients (44%) met the criteria for APBI only, while 116 (56%) should have been offered additional WBRT. Retrospective analysis showed that WBRT was applied statistically significantly less frequently compared with strict protocol indications: 99 patients (47.8%) received APBI only and 108 (51.2%) underwent adjuvant WBRT (p < 0.0001). Applying the TARGIT trial guidelines, 69 patients (33.4%) should have been offered WBRT (p < 0.0001), which is twice the number of patients treated with WBRT in our study. Changing the protocol to less restrictive criteria would have statistically significantly decreased the number of patients (95, 46%) offered WBRT (p < 0.0001).

Conclusions

Following international guidelines, 46% of patients should receive WBRT after IORT, which is 1.5–2 times more than for the TARGIT criteria. In our analysis, a high percentage of patients (19%) did not receive WBRT after IORT despite the protocol recommendations. The chosen protocol strongly influences the frequency of adjuvant WBRT.  相似文献   

13.
Whole breast irradiation represents an integral part of combined breast-conserving treatment of early breast cancer. A new concept includes replacing traditionally fractionated whole breast postoperative radiotherapy by accelerated partial breast irradiation. The latter involves a variety of techniques and may be applied intraoperatively or shortly after the surgery. The intraoperative techniques include photon or electron external beam irradiation and interstitial high dose rate (HDR) brachytherapy, whereas the postoperative techniques comprise interstitial brachytherapy, be it HDR, pulse dose rate (PDR) or low dose rate (LDR), intracavitary brachytherapy and external beam radiotherapy using electrons, photons or protons. This article presents accelerated partial breast irradiation techniques, ongoing phase III trials evaluating their value and recommendations for clinical practice.  相似文献   

14.
15.
Breast cancer (BC) is the most common tumour in women and one of the most important causes of cancer death worldwide. Radiation therapy (RT) is widely used for BC treatment. Some proteins have been identified as prognostic factors for BC (Ki67, p53, E‐cadherin, HER2). In the last years, it has been shown that variations in the expression of MMPs and TIMPs may contribute to the development of BC. The aim of this pilot work was to study the effects of RT on different MMPs (‐1, ‐2, ‐3, ‐7, ‐8, ‐9, ‐10, ‐12 and ‐13) and TIMPs (‐1 to ‐4), as well as their relationship with other variables related to patient characteristics and tumour biology. A group of 20 BC patients treated with RT were recruited. MMP and TIMP serum levels were analysed by immunoassay before, during and after RT. Our pilot study showed a slight increase in the levels of most MMP and TIMP with RT. However, RT produced a significantly decrease in TIMP‐1 and TIMP‐3 levels. Significant correlations were found between MMP‐3 and TIMP‐4 levels, and some of the variables studied related to patient characteristics and tumour biology. Moreover, MMP‐9 and TIMP‐3 levels could be predictive of RT toxicity. For this reason, MMP‐3, MMP‐9, TIMP‐3 and TIMP‐4 could be used as potential prognostic and predictive biomarkers for BC patients treated with RT.  相似文献   

16.
Background and purposeBreast reconstruction following mastectomy is a relevant element of breast cancer treatment. The purpose of this study was to evaluate the influence of radiotherapy (RT) on local complications in patients with breast cancer that had undergone breast reconstruction with alloplastic material.Materials and methodsRetrospective study of breast cancer patients submitted to mastectomy and breast reconstruction from 2009 to 2013. Clinical and treatment variables were correlated with early and late complications.Results251 patients were included; mean age was 49.7 (25 to 78) years. Reconstruction was immediate in 94% of the patients, with 88% performed with a temporary tissue expander. Postoperative radiotherapy (RT) was delivered to 167 patients (66.5%). Early complications were present in 26.3% of the patients. Irradiated patients presented 5.4% incidence of late complications versus 2.4% for non-irradiated patients (p = 0.327). Diabetes (OR = 3.41 95% CI: 1.23–9.45, p = 0.018) and high body mass index (BMI) (OR = 2.65; 95% CI: 1.60–4.37, p < 0.0001) were the main risk factors. The overall incidence of late complications was 4.4%, with predominance of severe capsular contracture (8/11). Arterial hypertension (OR = 4.78; 95% CI: 1.97–11.63, p = 0.001), BMI (OR = 0.170; 95% CI: 0.048–0.607, p = 0.006) and implant placement (OR = 3.55; 95% CI: 1.26–9.99, p = 0.016) were related to late complications.ConclusionsThe overall rate of complications was low in this population. Radiotherapy delivery translated into a higher but not statistically significant risk of late complications when compared with the non-irradiated patients. Already well-known clinical risk factors for complications after breast reconstruction were identified.  相似文献   

17.
PurposeTo evaluate the respiratory motion influence on the tridimensional (3D) dose delivery to breast-shaped phantoms using conformal radiotherapy (3D-RT), Field-in Field (FiF), and IMRT planning techniques.MethodsThis study used breast-shaped phantoms filled with MAGIC-f gel dosimeter to simulate the breast, and an oscillation platform to simulate the respiratory motion. The platform allowed motion in the anterior-posterior direction with oscillation amplitudes of 0.34 cm, 0.88 cm, and 1.22 cm. CT images of the static phantom were used for the 3D-RT, FiF, and IMRT treatment planning. Five phantoms were prepared and irradiated for each planning technique evaluated. Phantom 1 was irradiated static, phantoms 2–4 were irradiated moving with the three different motion amplitudes, and phantom 5 was used as a reference. The 3D dose distributions were obtained by relaxometry of magnetic resonance imaging, and the respiratory motion influence in the doses distribution was accessed by gamma evaluations (3%/3mm/15% threshold) comparing the measurements of the phantoms irradiated under movement with the static ones.ResultsThe mean gamma approvals for three oscillatory amplitudes were 96.44%, 93.23%, and 91.65%; 98.42%, 95.66%, and 94.31%; and 94.49%, 93.51%, and 86.62% respectively for 3D-RT, FiF and IMRT treatments. A gamma results profile per slice along the phantom showed that for FiF and IMRT irradiations, most of the failures occurred in the central region of the phantom.ConclusionsBy increasing the respiratory motion movement, the dose distribution variations for the three planning techniques were more pronounced, being the FiF technique variations the smallest one.  相似文献   

18.
Breast-conserving surgery including whole breast irradiation has long been a recommended procedure for early breast cancer. However, conventionally fractionated radiotherapy requires a lengthy hospitalisation or prolonged commuting to a hospital for radiotherapy. In recent years, hypofractionated radiotherapy has increasingly been used. This method involves higher fraction doses (above 2 Gy) as compared to conventional radiotherapy, so the total dose can be delivered in fewer fractions and in a shorter overall treatment time. This review aims at presenting most important outcomes of four randomised studies comparing conventional and hypofractionated radiotherapy schemes including a total of 7000 patients. These studies have not shown apparent differences in treatment efficacy, incidence of late post-radiotherapy complications or cosmetic effects during a 5–10 year follow-up, but longer observation is warranted to fully evaluate the safety of this method. Currently, major societies consider modestly hypofractionated radiotherapy schemes as a routine management in selected groups of patients undergoing breast-conserving surgery. However, this method should be used cautiously in patients with lymph node metastases, big breasts, receiving chemotherapy or trastuzumab, or those under 50 years of age.  相似文献   

19.
PurposeDue to limited field size of Magnetic Resonance Linear Accelerators (MR-Linac), some treatments could require a dual-isocenter planning approach to achieve a complete target coverage and thus exploit the benefits of the online adaptation. This study evaluates the dosimetric accuracy of the dual-isocenter intensity modulated radiation therapy (IMRT) delivery technique for MR-Linac.Material and MethodsDual-isocenter multi leaf collimator (MLC) and couch accuracy tests have been performed to evaluate the delivery accuracy of the system. A mono-isocenter plan delivered in clinical practice has then been retrospectively re-planned with dual-isocenter technique. The dual-isocenter plan has been re-calculated and delivered on a 3-dimensional (3D) ArcCHECK phantom and 2-dimensional (2D) films to assess its dosimetric accuracy in terms of gamma analysis. Clinical and planning target volume (CTV and PTV respectively) coverage robustness was then investigated after the introduction of ± 2 mm and ± 5 mm positioning errors by shifting the couch.ResultsMLC and couch accuracy tests confirmed the system accuracy in delivering a dual-isocenter irradiation.2D/3D gamma analysis results occurred always to be above 95% if considered a gamma criteria 1%/2 mm and 1%/1 mm respectively for the 2D and 3D analysis.The mean variations for CTV D98% and PTV V95% were 0.2% and 1.1% respectively when positioning error was introduced separately in each direction, while the maximum observed variations were 0.9% (CTV) and 3.7% (PTV).ConclusionThe dosimetric accuracy of dual-isocenter irradiation has been verified for MR-Linac, achieving accurate and robust treatment strategy and improving dose conformality also in presence of targets whose extension exceeds the nominal maximum field size.  相似文献   

20.
PurposeEvaluation of the out-of-field dose is an important aspect in radiotherapy. Due to the fetus radiosensitivity, this evaluation becomes even more conclusive when the patient is pregnant. In this work, a linear accelerator Varian Clinac 2100c operating at 6 MV, a pregnant anthropomorphic phantom (Maria), and different shields added above the abdominal region of the phantom were used for the analysis based on MCNPX. Methods: The simulations were performed for the medial and lateral projections, using either an open field collimation (10×16 cm2) or a multileaf collimator. The added shields (M1 and M2) were designed based on models proposed by Stovall et al. [1], intending to reduce the deposited dose on the fetus and related structures. Results: The presence of the shields showed to be effective in reducing the doses on the fetus, amniotic sac, and placenta, for example. A reduction of about 43% was found in the dose on the fetus when M2 was added, using the open field collimation, in comparison with the situation with no shield, being the lateral projection the main responsible for the dose. The use of MLC significatively reduced the doses in different structures, including on the fetus and amniotic sac, for example, in comparison to the open field situation. A slight increment on the dose in organs such as the eyes, thyroid and brain was found in both collimation systems, due to the presence of the shields. The contribution of the leakage radiation from the tube head of the linear accelerator was found to be in the order of µGy, being reduced by the presence of the M2 shield. Conclusion: Using the shields showed to be an essential feature in order to reduce the dose not only on the fetus, but also in important structures responsible to its development.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号