首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Principal component analysis of nonlinear chromatography   总被引:1,自引:0,他引:1  
Principal component analysis (PCA) has been used for the modeling of nonlinear chromatography under overload conditions. A 10-fold range of crude erythromycin samples were loaded onto columns with different stationary-phase chemistries (2 polystyrene, 1 methacrylate) in direct proportion to the bed volumes. The elution profiles indicated slightly concave isotherms for the polystyrene supports and a convex Langmuirian isotherm for the methacrylic support used. The principal component models accounted for over 98% of the original variance in the data for all three columns and were able to give excellent models of complete chromatograms in the absence of first-principle models or physicochemical data. Correlations between sample mass and the principal component scores were made for each that were consistent for the column types despite the different geometries and stationary phases. Linear relationships with high correlation coefficients were observed when the scores of the same principal component were compared between columns. Such correlations offer considerable potential for modeling of nonlinear chromatography.  相似文献   

2.
A nondestructive, sensitive assay to monitor the hydrocarbon content of silica-based chromatography particles has been developed. The assay requires a microscope accessory interfaced with a Fourier transform infrared (FTIR) spectrometer. For determining hydrocarbon content, undiluted alkyl-silica-bonded phases were pressed into a thin wafer. Hydrocarbon content was quantitated using the integrated hydrocarbon band intensity between 2995 and 2825 cm-1 [i.e., band area C-H] and the integrated silica oxide band intensity between 1945 and 1780 cm-1 [i.e., band area Si-O]. Plotting the [band area C-H]/[band area Si-O] ratio vs the carbon content determined by elemental analysis gave a correlation coefficient of r = 0.997. The FTIR assay was validated on 5-, 7-, and 12-microns silica particles using three different immobilized artificial membrane (IAM) silica-bonded phases. The utility of the FTIR assay in determining hydrocarbon content was demonstrated by evaluating hydrocarbon leaching from IAM phases exposed to mobile-phase solvents. The ability of organic solvents to leach hydrocarbon from IAM phases containing phosphatidylcholine (PC) as the immobilized ligand was chloroform greater than ethanol approximately methanol greater than ethyl acetate greater than methylene chloride greater than acetonitrile greater than acetone. Acetone and acetonitrile cause very little hydrocarbon leaching from HPLC-IAM.PC columns. When challenged with different mobile phases, IAM.PC columns perfused with mobile phase are more stable than IAM.PC-bonded phases stirred in mobile phases. IAM.PC contains lecithin linked to silica by amide bonds.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

3.
Application of cellulose-based chiral stationary phases was extended to open tubular columns. These chiral materials were mixed with achiral matrix stationary phases. Compromises were found among the polarity and the ratio of achiral matrix polymers against the content of the chiral cellulose derivative in order to optimize the resolution of the investigated racemates. In GC, the high efficiency feature of open tubular columns allows fast analysis, however, compounds which express strong H-bond interaction with cellulose derivatives elute with a bad peak shape. The application of these stationary phases for open tubular SFC was more successful, because the solvation power of the mobile phase can compensate the strong interaction between the solute and the cellulose derivative. Immobilization of the stationary phases were achieved for SFC purposes. © 1992 Wiley-Liss, Inc.  相似文献   

4.
We report here on the preparation of monolithic capillary columns in view to their integration in a microsystem for on-chip sample preparation before their on-line analysis by electrospray and mass spectrometry (ESI-MS). These monolithic columns are based on polymer materials and consist of reverse phases for peptide separation and/or desalting. They were prepared using lauryl methacrylate (LMA), ethylene dimethacrylate (EDMA) as well as a suitable porogenic mixture composed of cyclohexanol and ethylene glycol. The resulting stationary phases present thus a C12-functionality. The LMA-based columns were first prepared in a capillary format using capillary tubing of 75 microm i.d. and tested in nanoLC-MS experiments for the separation of a commercial Cytochrome C digest composed of 12 peptidic fragments whose isoelectric point values and hydrophobic character cover a wide range. The LMA-based columns were capable of separating the peptidic fragments and their performances were seen to be similar as those of standard commercial columns dedicated to proteomic purposes with calculated separation efficiencies up to 145 x 10(3) plates/m. Monolithic LMA-based phases were then successfully polymerized in microchannels fabricated using the negative photoresist SU-8. After the polymerization, the systems were seen to withstand the pressures applied during the nanoLC-MS separation tests that were carried out in the same conditions as for the monolithic capillary columns. The pressure drop during these tests of the in-microchannel monoliths was as high as 50 bar; however, the separation was not as good as for a capillary format which could be accounted for by the monolith dimensions.  相似文献   

5.
We have devised a new method for the fractionation of human plasma high density lipoprotein (HDL). The HDL was chromatographed on DEAE-agarose columns using a continuous gradient of 0.06--0.15 M NaCl. The elution pattern obtained showed three phases, each with differing peptide composition. Examination of the three subfraction showed that each contained both apoA-I and apo A-II, but in different proportions. Subfraction 1 contained no apo C-II or C-III-1 and only a trace of apo C-III-2, subfraction 2 contained apo C-II and C-III-1 but no C-III-2, while subfraction 3 contained considerable apo C-III-2 with only traces of apo C-II or C-III-1.  相似文献   

6.
Use of silica stationary phase and aqueous–organic mobile phases could significantly enhance LC–MS–MS method sensitivity. The LC conditions were compatible with MS detection. Analytes with basic functional groups were eluted with acidic mobile phases and detected by MS in the positive ion mode. Analytes with acid functional groups were eluted with mobile phases at neutral pH and detected by MS in the negative ion mode. Analytes poorly retained on reversed-phase columns showed good retention on silica columns. Compared with reversed-phase LC–MS–MS, 5–8-fold sensitivity increases were observed for basic polar ionic compounds when using silica columns and aqueous–organic mobile phase. Up to a 20-fold sensitivity increase was observed for acidic polar ionic compounds. Silica columns and aqueous–organic mobile phases were used for assaying nicotine, cotinine, and albuterol in biological fluids.  相似文献   

7.
Capillary gas-liquid chromatographic separation was studied for the complete set of the 26 theoretically possible isomers of mono-, di-, and trihydroxylated 5 beta-cholanic acids, which differ from one another in the number, position, and configuration of hydroxyl groups at C-3, C-7, and/or C-12 in the nucleus, as well as for some of their related acids. The bile acid samples were chromatographed as their methyl ester-trimethylsilyl (TMSi) ether derivatives and analyzed on three capillary columns coated with nonpolar OV-1, slightly polar OV-17, and polar SP-2340 as liquid phases. The retention times on capillary gas-liquid chromatography (GLC) responded dramatically to the minor structural differences, and almost complete separation of the positional and stereochemical isomers was achieved by the combined use of SP-2340 and OV-17 (or OV-1) capillary columns.  相似文献   

8.
This contribution deals with comparative studies on the chiral separation of thiazide diuretics using cellulose tris(3,5-dimethylphenylcarbamate) (Chiralcel OD-RH), cellulose tris(4-methylbenzoate) (Chiralcel OJ-R) and teicoplanin (Chirobiotic T) phases. All columns showed good chiral recognition ability for this class of compounds. Out of seven compounds investigated, six were resolved with baseline resolution with at least one of the three columns.  相似文献   

9.
The resolution and recovery of mixtures of the methyl ester acetates of synthetic and natural bile acids are excellent on gas-liquid chromatographic columns prepared with 1–3% OV-225 on 100–200 mesh Gas Chrom Q. The columns are operated isothermally at 250–260°C with helium as carrier gas and conventional gas chromatographic equipment. Under these conditions, complete separation of the major bile acids of rat and human bile is obtained in 30–60 min. This method of analysis is superior to that based on the trifluoroacetyl or trimethylsilyl derivatives, using OV-225 or other liquid phases.  相似文献   

10.
This review briefly summarizes the present state of the preparation and use of capillary monolithic columns for liquid chromatography (LC) and electrochromatography (EC). Most important approaches to the preparation of monolithic stationary phases based on organic polymers are outlined and the properties of the monoliths obtained are compared with those of classical particulate phases. A few selected applications of monolithic columns are shown to demonstrate the most important advantages of monolithic capillary columns. It is concluded that both the monolithic and particulate capillary columns are important and that judicious choice of the type suitable for a particular application requires careful consideration of the purpose of the separation and the properties of the solutes to be separated. Monolithic columns are substantially younger than packed ones and thus will require further theoretical and experimental study to further improve their preparation and to enable reliable prediction of their properties and applicability; nevertheless, they are very promising for the future.  相似文献   

11.
The optimal chromatographic conditions for the separation of the syn- and anti-geometric isomers of cefuroxime axetil applying RP-HPLC and micellar liquid chromatography (MLC) methods were investigated. The possibility to separate diastereoisomers of syn- and anti-cefuroxime axetil was observed. Investigations were performed using three columns, two classical silicas and one with hybrid particle technology. Three aqueous-organic and one micellar mobile phases were used. The best results were achieved using micellar mobile phase. Optimization study was performed using different micellar mobile phases. MLC method is sensitive and applicable in purity and stability testing.  相似文献   

12.
The performance of three different affinity and immunoaffinity subtraction spin columns was investigated for the removal of the most abundant proteins in human cerebrospinal fluid (CSF). A pool of human CSF was processed with the spin columns and both the bound and flow through fractions were compared with each other and with intact CSF using 1D gel electrophoresis and nanoLC–MALDI-TOF/TOF-MS analysis. MASCOT MS/MS ionscores were compared before and after processing with the columns. The non-specific co-removal of proteins bound to the high abundant proteins, so called “sponge effect” was also examined for each spin column. The reproducibility of one of the spin columns, ProteomeLab IgY-12 proteome partitioning spin column, was further investigated by isobaric tags for relative and absolute quantification (iTRAQ) labeling and MS/MS analysis. Overall, 173 unique proteins were identified on a 95% MudPIT confidence scoring level. For all three spin columns, the number of proteins identified and their MASCOT scores were increased up to 10 times. The largest degree of non-specific protein removal was observed for a purely affinity based albumin removal column, where 28 other proteins also were present. The ProteomeLab IgY-12 proteome partitioning spin column showed very high reproducibility when combined with iTRAQ labeling and MS/MS analysis. The combined relative standard deviation (R.S.D.) for the high abundant protein removal, iTRAQ labeling and nanoLC–MALDI-TOF/TOF-MS analysis was less than 17.5%.  相似文献   

13.
Various liquid phases for glass capillary columns have been evaluated for gas-liquid chromatographic analysis of methyl ester trimethylsilylether derivatives of bile acids from serum and bile. Bile acid analysis is rapid and exhibits high separation efficiency with a 20 X 0.3 mm glass capillary column whose internal surface is covered with a crystal layer of barium carbonate and coated with polyethyleneglycol 20000 as liquid phase according to Grob et al.  相似文献   

14.
This review article summarizes the recent progress on bioanalytical LC-MS/MS methods using underivatized silica columns and aqueous/organic mobile phases. Various types of polar analytes were extracted by using protein precipitation (PP), liquid/liquid extraction (LLE) or solid-phase extraction (SPE) and were then analyzed using LC-MS/MS on the silica columns. Use of silica columns and aqueous/organic mobile phases could significantly enhance LC-MS/MS method sensitivity, due to the high organic content in the mobile phase. Thanks to the very low backpressure generated from the silica column with low aqueous/high organic mobile phases, LC-MS/MS methods at high flow rates are feasible, resulting in significant timesaving. Because organic solvents have weaker eluting strength than water, direct injection of the organic solvent extracts from the reversed-phase solid-phase extraction onto the silica column was possible. Gradient elution on the silica columns using aqueous/organic mobile phases was also demonstrated. Contrary to what is commonly perceived, the silica column demonstrated superior column stability. This technology can be a valuable supplement to the reversed-phase LC-MS/MS.  相似文献   

15.
Components of the sterol fraction of tobacco and marijuana were resolved as trimethylsilyl derivatives by gas chromatography with glass capillary columns. Ten phytosterols in tobacco and five in marijuana were identified by comparisons of their retention with authentic compounds on three different stationary phases and through mass-spectral data.  相似文献   

16.
We investigate the effect of the addition of a trivalent cation, spermidine, to dilute solutions of nucleosome core particles (NCP). In the presence of spermidine, part of the NCP segregates from the initial homogeneous solution, forming dense aggregates. We follow this precipitation process over a wide range of spermidine and NaCl concentrations and determine the conditions of aggregation of the particles. The structure of the dense phases is analyzed by means of polarizing light microscopy and cryo-electron microscopy. We report the existence of multiple supramolecular organizations. According to the relative concentrations of spermidine, monovalent salt and NCP, the particles may aggregate into amorphous phases, stack into randomly oriented columns, or form liquid crystalline phases. Two discotic liquid crystalline phases are identified and analyzed: a columnar nematic corresponding to columns of NCP simply aligned in parallel, and a columnar hexagonal phase in which the columns order into a transversal 2D hexagonal array. We discuss the nature and origin of the interactions possibly involved in the formation and maintenance of these different types of order.  相似文献   

17.
A superficially porous particle (SPP)‐based hydroxypropyl‐β‐cyclodextrin (HPBCD) chiral stationary phase (CSP) was produced and its chromatographic performance was compared to both 5 µm and 3 µm fully porous particle (FPP)‐based CSPs. The relative surface coverage of the HPBCD chiral selector on each particle was approximately equal, which resulted in equivalent enantiomeric selectivity (α) values on each phase when constant mobile phase conditions were used. Under such conditions, the SPP column resulted in greatly reduced analysis times and three times greater efficiencies compared to the FPP columns. When higher flow rates were used, efficiency gains per analysis times were five times greater for the SPP column compared to the FPP‐based columns. When the mobile phases were altered to give similar analysis times on each column, resolution values were doubled for the SPP column. Finally, the novel SPP based HPBCD column proved to be stable for 500 injections under high flow rate (4.5 mL/min) and high pressure (400 bar) conditions used for an ultrafast (~45 sec) enantiomeric separation. Chirality 27:788–794, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

18.
HPLC methods for protein and peptide analysis are excellent in terms of resolution, selectivity and recovery. They are, however, complex procedures involving multiple parameters including instrumentation, columns and mobile phases that may lead to inter- or intra-laboratory deviations. The factors that contribute to differences in retention, selectivity and sensitivity are discussed, followed by suggestions for eliminating or compensating for the differences.  相似文献   

19.
This paper reports the development of liquid chromatographic columns containing immobilized organic anion transporters (hOAT1 and hOAT2). Cellular membrane fragments from MDCK cells expressing hOAT1 and S2 cells expressing hOAT2 were immobilized on the surface of the immobilized artificial membrane (IAM) liquid chromatographic stationary phase. The resulting stationary phases were characterized by frontal affinity chromatography, using the marker ligand [3H]-adefovir for the hOAT1 and [14C]-p-aminohippurate for the hOAT2 in the presence of multiple displacers. The determined binding affinities (Kd) for eight OAT1 ligands and eight OAT2 ligands were correlated with literature values and a statistically significant correlation was obtained for both the hOAT1 and hOAT2 columns: r2=0.688 (p<0.05) and r2=0.9967 (p<0.0001), respectively. The results indicate that the OAT1 and OAT2 have been successfully immobilized with retention of their binding activity. The use of these columns to identify ligands to the respective transporters will be presented.  相似文献   

20.
The performance of monolithic HPLC columns Chromolith (made by Merck, Germany) and conventional C18 columns Discovery (Supelco, Sigma-Aldrich, Prague, Czech Republic) was tested and the comparison for two topical preparations Ketoprofen gel and Estrogel gel was made. The composition of mobile phases - for Ketoprofen analysis a mixture of acetonitrile, water and phosphate buffer adjusted to pH 3.5 (40:58:2) and for Estrogel analysis a mixture of acetonitrile, methanol, water (23:24:53) - was usually not optimal for analyses at all types of columns. Thus an adjustment of components ratio was necessary for sufficient resolution of the compounds analysed. Various flow rates (1.0-5.0 ml/min) and mobile phases (usually increasing ratio of water content) were applied. Determination of active substances, preservatives and impurities and comparison of retention times and system suitability test parameters was accomplished. For Estrogel gel, following chromatographic conditions were found: using Chromolith Flash RP-18e monolith column, mobile phase was acetonitrile, methanol, water (13:24:63, v/v/v) and flow-rate 3.0 ml/min. Using monolith column ChromolithSpeedROD RP-18e, the mobile phase was acetonitrile, methanol, water (18:24:58, v/v/v) and flow-rate 4.0 ml/min. For the monolith column Chromolith Performance RP-18e, the mobile phase was acetonitrile, methanol, water (23:24:53, v/v/v), flow-rate 3.0ml/min. Analysis of Ketoprofen gel gave the best results using following analytical conditions: for monolith column Chromolith Flash RP-18e, mobile phase as a mixture of acetonitrile, water, phosphate buffer pH 3.5 (30:68:2, v/v/v) was used, at flow-rate 2.0 ml/min. For ChromolithSpeedROD RP-18e monolith column, acetonitrile, water, phosphate buffer pH 3.5 (35:63:2, v/v/v) was used as a mobile phase at flow-rate 3.0 ml/min. Chromolith Performance RP-18e gave the best results using mobile phase acetonitrile, water, phosphate buffer pH 3.5 (30:68:2, v/v/v) at the flow-rate 5.0 ml/min. It was proved that monolith columns, due to their porosity and low back-pressure, can save analysis time by about a factor of three with sufficient separation efficiency. Thus, for example 11 min long analysis can be performed in 4 min with comparable results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号