首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In barley (Hordeum vulgare L.) leaves, differential ion accumulation commonly results in inorganic phosphate (Pi) being confined to the mesophyll and Ca(2+) to the epidermis, with preferential epidermal accumulation of Cl(-), Na(+), and some other ions. The pattern was confirmed in this study for major inorganic anions and cations by analysis of barley leaf protoplasts. The work focused on the extent to which differences in plasma membrane ion transport processes underlie these observations. Ion transport across the plasma membrane of barley epidermal and mesophyll protoplasts was investigated electrophysiologically (by microelectrode impalement and patch clamping) and radiometrically. Data from both approaches suggested that similar types of ion-selective channels and membrane transporters, which catalyze the transport of Ca(2+), K(+), Na(+), and Pi, exist in the plasma membrane of the two cell types. In general, the simple presence or absence of ion transporters could not explain cell-type-specific differences in ion accumulation. However, patch-clamp data suggested that differential regulation of instantaneously activating ion channels in the plasma membrane could explain the preferential accumulation of Na(+) in the epidermis.  相似文献   

2.
The measurement of membrane affinity is an important early screening step during drug discovery. However, classical methods for membrane affinity measurement are tedious and difficult to implement in high-throughput screening. This article describes a quantitative method for the measurement of membrane affinity by colorimetric assay based on polydiacetylene (PDA) sensors. Prepared lipid/PDA chromatic vesicles were used to model cell membranes. By measuring the colorimetric response of the chromatic vesicles when drug-membrane interactions occurred, membrane affinity constant K(b) could be calculated using a simple quantitative model. Under optimized preparation conditions, the calculated log(K(b)) values exhibited an in-batch relative standard deviation (RSD) of less than 4% and a between-batch RSD of less than 8% for all three reference compounds. The logarithm of K(b) of the six β-blockers exhibited excellent linear correlation with the logarithm of the liposome/water partition coefficient (K(m)) with R(2)=0.9793. For neutral compounds, the log(K(b)) of n-fatty alcohols correlated with the logarithm of the n-octanol/water partition coefficient (K(oct)) with a linear correlation coefficient R(2)=0.9833. This work provides a simple, convenient, and reproducible method for the rapid measurement of membrane affinity and presents important implications for high-throughput screening.  相似文献   

3.
Application of patch clamp techniques to higher-plant cells has been subject to the limitation that the requisite contact of the patch electrode with the cell membrane necessitates prior enzymatic removal of the plant cell wall. Because the wall is an integral component of plant cells, and because cell-wall-degrading enzymes can disrupt membrane properties, such enzymatic treatments may alter ion channel behavior. We compared ion channel activity in enzymatically isolated protoplasts of Vicia faba guard cells with that found in membranes exposed by a laser microsurgical technique in which only a tiny portion of the cell wall is removed while the rest of the cell remains intact within its tissue environment. "Laser-assisted" patch clamping reveals a new category of high-conductance (130 to 361 pS) ion channels not previously reported in patch clamp studies on plant plasma membranes. These data indicate that ion channels are present in plant membranes that are not detected by conventional patch clamp techniques involving the production of individual plant protoplasts isolated from their tissue environment by enzymatic digestion of the cell wall. Given the large conductances of the channels revealed by laser-assisted patch clamping, we hypothesize that these channels play a significant role in the regulation of ion content and electrical signalling in guard cells.  相似文献   

4.
Summary Application of patch clamp techniques to higher-plant cells has been subject to the limitation that the requisite contact of the patch electrode with the cell membrane necessitates prior enzymatic removal of the plant cell wall. Because the wall is an integral component of plant cells, and because cell-wall-degrading enzymes can disrupt membrane properties, such enzymatic treatments may alter ion channel behavior. We compared ion channel activity in enzymatically isolated protoplasts ofVicia faba guard cells with that found in membranes exposed by a laser microsurgical technique in which only a tiny portion of the cell wall is removed while the rest of the cell remains intact within its tissue environment. “Laserassisted” patch clamping reveals a new category of high-conductance (130 to 361 pS) ion channels not previously reported in patch clamp studies on plant plasma membranes. These data indicate that ion channels are present in plant membranes that are not detected by conventional patch clamp techniques involving the production of individual plant protoplasts isolated from their tissue environment by enzymatic digestion of the cell wall. Given the large conductances of the channels revealed by laser-assisted patch clamping, we hypothesize that these channels play a significant role in the regulation of ion content and electrical signalling in guard cells.  相似文献   

5.
6.
During a genomic survey of the transparent sea squirt (Ciona intestinalis), Murata et al. discovered a gene that encodes a protein containing homologous sequences to both a CX(5)R phosphatase and an ion channel. The authors named the novel protein, C. intestinalis voltage-sensor-containing phosphatase, Ci-VSP. The N terminus of Ci-VSP appears to function as a voltage-gated sensor; the C terminus functions as a phosphoinositide phosphatase. The authors suggest that when the N-terminal voltage sensor is activated, this in turn activates the phosphatase, which converts PI(3,4,5)P(3) to PI(4,5)P(2). Localized changes in membrane PI(4,5)P(2) levels could then serve to either positively or negatively regulate a variety of ion transporters and channels.  相似文献   

7.
We have used ion-selective electrodes (ISEs) to quantify ion fluxes across giant membrane patches by measuring and simulating ion gradients on both membrane sides. Experimental conditions are selected with low concentrations of the ions detected on the membrane side being monitored. For detection from the cytoplasmic (bath) side, the patch pipette is oscillated laterally in front of an ISE. For detection on the extracellular (pipette) side, ISEs are fabricated from flexible quartz capillary tubing (tip diameters, 2-3 microns), and an ISE is positioned carefully within the patch pipette with the tip at a controlled distance from the mouth of the patch pipette. Transport activity is then manipulated by solution changes on the cytoplasmic side. Ion fluxes can be quantified by simulating the ion gradients with appropriate diffusion models. For extracellular (intrapatch pipette) recordings, ion diffusion coefficients can be determined from the time courses of concentration changes. The sensitivity and utility of the methods are demonstrated with cardiac membrane patches by measuring (a) potassium fluxes via ion channels, valinomycin, and Na/K pumps; (b) calcium fluxes mediated by Na/Ca exchangers; (c) sodium fluxes mediated by gramicidin and Na/K pumps; and (d) proton fluxes mediated by an unknown electrogenic mechanism. The potassium flux-to-current ratio for the Na/K pump is approximately twice that determined for potassium channels and valinomycin, as expected for a 3Na/2K pump stoichiometery (i.e., 2K/charge moved). For valinomycin-mediated potassium currents and gramicidin-mediated sodium currents, the ion fluxes calculated from diffusion models are typically 10-15% smaller than expected from the membrane currents. As presently implemented, the ISE methods allow reliable detection of calcium and proton fluxes equivalent to monovalent cation currents <1 pA in magnitude, and they allow detection of sodium and potassium fluxes equivalent to <5 pA currents. The capability to monitor ion fluxes, independent of membrane currents, should facilitate studies of both electrogenic and electroneutral ion-coupled transporters in giant patches.  相似文献   

8.
The transport of mineral ions into and out of tissues and cells is central to the life of plants. Ion transport and the plasma membrane transporters themselves have been studied using a variety of techniques. In the last 15 years, measurement of specific ion fluxes has contributed to the characterization of transport systems. Progress in molecular genetics is allowing gene identification and controlled expression of transporter molecules. However the molecular expression of transporter gene products must be characterized at the functional level. The ion‐selective microelectrode technique to measure specific ion fluxes non‐invasively is ideally suited to this purpose. This technique, its theory, its links with others and its application and prospects in plant science, are discussed. Ions studied include hydrogen, potassium, sodium, ammonium, calcium, chloride and nitrate. Applications discussed include: solute ion uptake by roots; gravitropism and other processes in the root cap, meristematic and elongation zones; Nod factor effect on root hairs; osmotic and salt stresses; oscillations; the effects of light and temperature. Studies have included intact roots, leaf mesophyll and other tissues, protoplasts and bacterial biofilms. A multi‐ion capability of the technique will greatly assist functional genomics, particularly when coupled with imaging techniques, patch clamping and the use of suitable mutants.  相似文献   

9.
Whole cell patch clamp recording performed on a planar glass chip   总被引:6,自引:0,他引:6       下载免费PDF全文
The state of the art technology for the study of ion channels is the patch clamp technique. Ion channels mediate electrical current flow, have crucial roles in cellular physiology, and are important drug targets. The most popular (whole cell) variant of the technique detects the ensemble current over the entire cell membrane. Patch clamping is still a laborious process, requiring a skilled experimenter to micromanipulate a glass pipette under a microscope to record from one cell at a time. Here we report on a planar, microstructured quartz chip for whole cell patch clamp measurements without micromanipulation or visual control. A quartz substrate of 200 microm thickness is perforated by wet etching techniques resulting in apertures with diameters of approximately 1 microm. The apertures replace the tip of glass pipettes commonly used for patch clamp recording. Cells are positioned onto the apertures from suspension by application of suction. Whole cell recordings from different cell types (CHO, N1E-115 neuroblastoma) are performed with microstructured chips studying K(+) channels and voltage gated Ca(2+) channels.  相似文献   

10.
Patch clamp electrophysiology is the main technique to study mechanosensitive ion channels (MSCs), however, conventional patch clamping is laborious and success and output depends on the skills of the operator. Even though automated patch systems solve these problems for other ion channels, they could not be applied to MSCs. Here, we report on activation and single channel analysis of a bacterial mechanosensitive ion channel using an automated patch clamp system. With the automated system, we could patch not only giant unilamellar liposomes but also giant Escherichia coli (E. coli) spheroplasts. The tension sensitivity and channel kinetics data obtained in the automated system were in good agreement with that obtained from the conventional patch clamp. The findings will pave the way to high throughput fundamental and drug screening studies on mechanosensitive ion channels.  相似文献   

11.
K+ is one of the cations (besides protons) whose transport across the plasma membrane is believed to contribute to the maintenance of membrane potential. To ensure K+ transport, Saccharomyces cerevisiae cells possess several types of active and passive transporters mediating the K+ influx and efflux, respectively. A diS-C3(3) assay was used to compare the contributions of various potassium transporters to the membrane potential changes of S. cerevisiae cells in the exponential growth phase. Altogether, the contributions of six K+ transporters to the maintenance of a stable membrane potential were tested. As confirmed by the observed hyperpolarization of trk1 trk2 deletion strains, the diS-C3(3) assay is a suitable method for comparative studies of the membrane potential of yeast strains differing in the presence/absence of one or more cation transporters. We have shown that the presence of the Tok1 channel strongly influences membrane potential: deletion of the TOK1 gene results in significant plasma membrane depolarization, whereas strains overexpressing the TOK1 gene are hyperpolarized. We have also proved that plasma membrane potential is not the only parameter determining the hygromycin B sensitivity of yeast cells, and that the role of intracellular transporters in protecting against its toxic effects must also be considered.  相似文献   

12.
Ion channel activity in cell-attached patch recordings shows channel behavior under more physiological conditions than whole-cell and excised patch measurements. Yet the analysis of cell-attached patch measurements is complicated by the fact that the system is ill defined with respect to the intracellular ion activities and the electrical potential actually experienced by the membrane patch. Therefore, of the several patch-clamp configurations, the information that is obtained from cell-attached patch measurements is the most ambiguous. The present study aims to achieve a better understanding of cell-attached patch measurements. Here we describe a method to calculate the intracellular ion concentration and membrane potential prevailing during cell-attached patch recording. The first step is an analysis of the importance of the input resistance of the intact cell on the cell-attached patch measurement. The second step, and actual calculation, is based on comparison of the single channel conductance and reversal potential in the cell-attached patch and excised patch configurations. The method is demonstrated with measurements of membrane potential and cytosolic K+ concentrations in Vicia faba guard cells. The approach described here provides an attractive alternative to the measurement of cytosolic ion concentrations with fluorescent probes or microelectrodes. Received: 3 April 1998/Revised: 6 August 1998  相似文献   

13.
The early receptor current (ERC) is the charge redistribution occurring in plasma membrane rhodopsin during light activation of photoreceptors. Both the molecular mechanism of the ERC and its relationship to rhodopsin conformational activation are unknown. To investigate whether the ERC could be a time-resolved assay of rhodopsin structure-function relationships, the distinct sensitivity of modern electrophysiological tools was employed to test for flash-activated ERC signals in cells stably expressing normal human rod opsin after regeneration with 11-cis-retinal. ERCs are similar in waveform and kinetics to those found in photoreceptors. The action spectrum of the major R(2) charge motion is consistent with a rhodopsin photopigment. The R(1) phase is not kinetically resolvable and the R(2) phase, which overlaps metarhodopsin-II formation, has a rapid risetime and complex multiexponential decay. These experiments demonstrate, for the first time, kinetically resolved electrical state transitions during activation of expressed visual pigment in a unicellular environment (single or fused giant cells) containing only 6 x 10(6)-8 x 10(7) molecules of rhodopsin. This method improves measurement sensitivity 7 to 8 orders of magnitude compared to other time-resolved techniques applied to rhodopsin to study the role particular amino acids play in conformational activation and the forces that govern those transitions.  相似文献   

14.
The nonradioactive Rb+ efflux assay has become a reliable and efficient high-throughput hERG screening method, but it is limited by its low sensitivity for potent hERG blockers. Using the patch clamp technique, the authors found that the low sensitivity is due in part to the use of Rb+ as the permeating cation in the assay. The affinities of the drugs measured by patch clamp technique in the presence of Rb+ were 3- to 10-fold lower than when measured by the same method in the presence of K+ ions. The apparent affinity of the drugs decreased even further when monitored by the Rb+ efflux assay. It was also observed that Rb+ had minimal effects on the activation properties of channels while there was a significant change in the half-inactivation potential. This voltage shift reduces hERG channel inactivation at efflux assay potentials, and will reduce the affinity of hERG-blocking drugs that bind to inactivated states of the channel. In combination with the effects of elevated extracellular ion concentrations, it is likely that Rb+ modulation of hERG channel inactivation is largely responsible for the reduced drug potencies observed in the Rb+ efflux assay.  相似文献   

15.
16.
We here describe a protocol for fusing vesicles into large structures suitable for patch clamp recording. The method may be used with native membrane vesicles or with liposomes containing reconstituted/purified ion channels. The resulting unilamellar membranes exhibit high channel surface abundance, yielding multiple channels in the average excised patch. The procedure has been used to record voltage-sensitive Na channels from three native membrane preparations (eel electroplax, rat skeletal muscle, squid optic nerve), and from reconstituted protein purified from eel electroplax. Channels treated with batrachotoxin (BTX) displayed characteristic activation voltage dependence, conductances, selectivity, and sensitivity to saxitoxin (STX).  相似文献   

17.
Many high-throughput ion channel assays require the use of voltage-sensitive dyes to detect channel activity in the presence of test compounds. Dye systems employing F?rster resonance energy transfer (FRET) between 2 membrane-bound dyes are advantageous in combining high sensitivity, relatively fast response, and ratiometric output. The most widely used FRET voltage dye system employs a coumarin fluorescence donor whose excitation spectrum is pH dependent. The authors have validated a new class of voltage-sensitive FRET donors based on a pyrene moiety. These dyes are significantly brighter than CC2-DMPE and are not pH sensitive in the physiological range. With the new dye system, the authors demonstrate a new high-throughput assay for the acid-sensing ion channel (ASIC) family. They also introduce a novel method for absolute calibration of voltage-sensitive dyes, simultaneously determining the resting membrane potential of a cell.  相似文献   

18.
An underlying mechanism for multi drug resistance (MDR) is up-regulation of the transmembrane ATP-binding cassette (ABC) transporter proteins. ABC transporters also determine the general fate and effect of pharmaceutical agents in the body. The three major types of ABC transporters are MDR1 (P-gp, P-glycoprotein, ABCB1), MRP1/2 (ABCC1/2) and BCRP/MXR (ABCG2) proteins. Flow cytometry (FCM) allows determination of the functional expression levels of ABC transporters in live cells, but most dyes used as indicators (rhodamine 123, DiOC(2)(3), calcein-AM) have limited applicability as they do not detect all three major types of ABC transporters. Dyes with broad coverage (such as doxorubicin, daunorubicin and mitoxantrone) lack sensitivity due to overall dimness and thus may yield a significant percentage of false negative results. We describe two novel fluorescent probes that are substrates for all three common types of ABC transporters and can serve as indicators of MDR in flow cytometry assays using live cells. The probes exhibit fast internalization, favorable uptake/efflux kinetics and high sensitivity of MDR detection, as established by multidrug resistance activity factor (MAF) values and Kolmogorov-Smirnov statistical analysis. Used in combination with general or specific inhibitors of ABC transporters, both dyes readily identify functional efflux and are capable of detecting small levels of efflux as well as defining the type of multidrug resistance. The assay can be applied to the screening of putative modulators of ABC transporters, facilitating rapid, reproducible, specific and relatively simple functional detection of ABC transporter activity, and ready implementation on widely available instruments.  相似文献   

19.
Fluorometric imaging plate reader (FLIPR) membrane potential dyes (FMP-Red-Dye and FMP-Blue-Dye) were evaluated for the detection of compounds acting either as positive allosteric modulators or agonists on the GABA(A) receptor (GABA(A)R). A stable HEK293 cell line with constitutive expression of the rat GABA(A)R alpha1, beta2, and gamma2 genes was used to establish a functional high-throughput screening (HTS) assay based on measurement of the membrane potential change in living cells. The assay was validated with the FLIPR technology for identification of agonists and positive allosteric modulators using GABA and diazepam as model compounds. The FMP-Red-Dye showed better performance than the FMP-Blue-Dye, and the effects induced by GABA and diazepam were comparable to electrophysiology data. Subsequently, the assay was also validated with an ultra-HTS approach known as microarrayed compound screening (microARCS). The LOPAC library was used in a test screen for an initial assessment of the technology. Finally, the FLIPR and microARCS technologies were tested with a larger screening campaign. A focused library of 3520 putative positive modulators was tested with the FLIPR assay, and a diverse subset of 84,480 compounds was selected for screening with the microARCS technology. All hits were subjected to verification using the FLIPR technology, and confirmed hits were subsequently evaluated by EC50 determination. Finally, selected hits were further confirmed with electrophysiology testing.  相似文献   

20.
The mechanosensitive (MS) ion channel is gated by changes in bilayer deformation. It is functional without the presence of any other proteins and gating of the channel has been successfully achieved using conventional patch clamping techniques where a voltage has been applied together with a pressure over the membrane. Here, we have for the first time analyzed the large conducting (MscL) channel in a supported membrane using only an external electrical field. This was made possible using a newly developed technique utilizing a tethered lipid bilayer membrane (tBLM), which is part of an engineered microelectronic array chip. Single ion channel activity characteristic for MscL was obtained, albeit with lower conductivity. The ion channel was gated using solely a transmembrane potential of 300 mV. Computations demonstrate that this amount of membrane potential induces a membrane tension of 12 dyn/cm, equivalent to that calculated to gate the channel in patch clamp from pressure-induced stretching of the bilayer. These results strengthen the supposition that the MscL ion channel gates in response to stress in the lipid membrane rather than pressure across it. Furthermore, these findings illustrate the possibility of using the MscL as a release valve for engineered membrane devices; one step closer to mimicking the true function of the living cell.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号