首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Purpose

This study aims to compare the biomechanical properties of the novel pedicle screw and plate system with the traditional rod system in asymmetrical posterior stabilization for minimally invasive transforaminal lumbar interbody fusion (MI-TLIF). We compared the immediate stabilizing effects of fusion segment and the strain distribution on the vertebral body.

Methods

Seven fresh calf lumbar spines (L3-L6) were tested. Flexion/extension, lateral bending, and axial rotation were induced by pure moments of ± 5.0 Nm and the range of motion (ROM) was recorded. Strain gauges were instrumented at L4 and L5 vertebral body to record the strain distribution under flexion and lateral bending (LB). After intact kinematic analysis, a right sided TLIF was performed at L4-L5. Then each specimen was tested for the following constructs: unilateral pedicle screw and rod (UR); unilateral pedicle screw and plate (UP); UR and transfacet pedicle screw (TFS); UP and TFS; UP and UR.

Results

All instrumented constructs significantly reduced ROM in all motion compared with the intact specimen, except the UR construct in axial rotation. Unilateral fixation (UR or UP) reduced ROM less compared with the bilateral fixation (UP/UR+TFS, UP+UR). The plate system resulted in more reduction in ROM compared with the rod system, especially in axial rotation. UP construct provided more stability in axial rotation compared with UR construct. The strain distribution on the left and right side of L4 vertebral body was significantly different from UR and UR+TFS construct under flexion motion. The strain distribution on L4 vertebral body was significantly influenced by different fixation constructs.

Conclusions

The novel plate could provide sufficient segmental stability in axial rotation. The UR construct exhibits weak stability and asymmetrical strain distribution in fusion segment, while the UP construct is a good alternative choice for unilateral posterior fixation of MI-TLIF.  相似文献   

2.

Study Design

Meta-analysis.

Background

Bilateral pedicle screw fixation (PS) after lumbar interbody fusion is a widely accepted method of managing various spinal diseases. Recently, unilateral PS fixation has been reported as effective as bilateral PS fixation. This meta-analysis aimed to comparatively assess the efficacy and safety of unilateral PS fixation and bilateral PS fixation in the minimally invasive (MIS) lumbar interbody fusion for one-level degenerative lumbar spine disease.

Methods

MEDLINE/PubMed, EMBASE, BIOSIS Previews, and Cochrane Library were searched through March 30, 2014. Randomized controlled trials (RCTs) and controlled clinical trials (CCTs) on unilateral versus bilateral PS fixation in MIS lumbar interbody fusion that met the inclusion criteria and the methodological quality standard were retrieved and reviewed. Data on participant characteristics, interventions, follow-up period, and outcomes were extracted from the included studies and analyzed by Review Manager 5.2.

Results

Six studies (5 RCTs and 1 CCT) involving 298 patients were selected. There were no significant differences between unilateral and bilateral PS fixation procedures in fusion rate, complications, visual analogue score (VAS) for leg pain, VAS for back pain, Oswestry disability index (ODI). Both fixation procedures had similar length of hospital stay (MD = 0.38, 95% CI = −0.83 to 1.58; P = 0.54). In contrast, bilateral PS fixation was associated with significantly more intra-operative blood loss (P = 0.002) and significantly longer operation time (P = 0.02) as compared with unilateral PS fixation.

Conclusions

Unilateral PS fixation appears as effective and safe as bilateral PS fixation in MIS lumbar interbody fusion but requires less operative time and causes less blood loss, thus offering a simple alternative approach for one-level lumbar degenerative disease.  相似文献   

3.

Objective

The objective of this biomechanical study was to evaluate the stability provided by a newly developed shape memory alloy hook (SMAH) in a cadaveric transforaminal lumbar interbody fusion (TLIF) model.

Methods

Six human cadaveric spines (L1-S2) were tested in an in vitro flexibility experiment by applying pure moments of ±8 Nm in flexion/extension, left/right lateral bending, and left/right axial rotation. After intact testing, a TLIF was performed at L4-5. Each specimen was tested for the following constructs: unilateral SMAH (USMAH); bilateral SMAH (BSMAH); unilateral pedicle screws and rods (UPS); and bilateral pedicle screws and rods (BPS). The L3–L4, L4–L5, and L5-S1 range of motion (ROM) were recorded by a Motion Analysis System.

Results

Compared to the other constructs, the BPS provided the most stability. The UPS significantly reduced the ROM in extension/flexion and lateral bending; the BSMAH significantly reduced the ROM in extension/flexion, lateral bending, and axial rotation; and the USMAH significantly reduced the ROM in flexion and left lateral bending compared with the intact spine (p<0.05). The USMAH slightly reduced the ROM in extension, right lateral bending and axial rotation (p>0.05). Stability provided by the USMAH compared with the UPS was not significantly different. ROMs of adjacent segments increased in all fixed constructs (p>0.05).

Conclusions

Bilateral SMAH fixation can achieve immediate stability after L4–5 TLIF in vitro. Further studies are required to determine whether the SMAH can achieve fusion in vivo and alleviate adjacent segment degeneration.  相似文献   

4.

Background

Transforaminal lumbar interbody fusion (TLIF) has become one of the most widely used procedures for lumbar spinal disorders. However, it is still unclear whether TLIF with unilateral pedicle screw (PS) fixation is as effective as that with bilateral PS fixation. We performed a meta-analysis of the literatures and aimed to gain a better understanding of whether TLIF with unilateral PS fixation was safe and effective for lumbar diseases.

Methodology/Principal Findings

We systematically searched Ovid, Springer, and Medline databases for relevant randomized controlled trials (RCTs) that compared the clinical and radiological outcomes of unilateral versus bilateral PS fixation in TLIF. Risk of bias in included studies was assessed using the Cochrane Risk of Bias tool. We generated pooled risk ratios or weighted mean differences across studies. According to our predefined inclusion criteria, seven RCTs with a total of 441 patients were included in this study. Baseline characteristics were similar between the unilateral and bilateral groups. Our meta-analysis showed that no significant difference was detected between the two groups in terms of postoperative clinical function, fusion status, reoperation rate, complication rate, and hospital stay (p>0.05). Pooled estimates revealed that the unilateral group was associated with significantly reduced implant cost, operative time and blood loss (p<0.05).

Conclusions/Significances

Our meta-analysis suggested TLIF with unilateral PS fixation was as safe and effective as that with bilateral PS fixation for lumbar diseases in selected patients. Despite these findings, our meta-analysis was based on studies with small sample size and different study characteristics that might lead to the inconsistent results such as various functional outcomes among the included studies. Therefore, high-quality randomized controlled trials with larger sample size are also needed to further clarify these issues and to provide the long-term outcomes.  相似文献   

5.

Objectives

To identify the negative effect on treatment results of reserving damaged intervertebral discs when treating type B and type C spinal fracture-dislocations through a one-stage posterior approach.

Methods

This is a retrospective review of 53 consecutive patients who were treated in our spine surgery center from January 2005 to May 2012 due to severe thoracolumbar spinal fracture-dislocation. The patients in Group A (24 patients) underwent long-segment instrumentation laminectomy with pedicle screw-rod fixators for neural decompression. In Group B (29 patients), the patients underwent long-segment instrumentation laminectomy with pedicle screw-rod fixators for neural decompression evacuating of the ruptured disc and inserting of a bone graft into the evacuated disc space for interbody fusion. The mean time between injury and operation was 4.1 days (range 2–15 days). The clinical, radiologic and complication outcomes were analyzed retrospectively.

Results

Periodic follow-ups were carried out until an affirmative union or treatment failure took place. A progressive kyphosis angle larger than 10°, loss of disc height, pseudoarthrosis, recurrence of dislocation or subluxation, or instrument failure before fusion were considered treatment failures. Treatment failures were detected in 13 cases in Group A (failure rate was 54.2%). In Group B, there were 28 cases in which definitive bone fusion was demonstrated on CT scans, and CT scans of the other cases demonstrated undefined pseudoarthrosis without hardware failure. There were statistically significant differences between the two groups (p<0.001 chi-square test). The neurologic recoveries, assessed by the ASIA scoring system, were not satisfactory for the neural deficit patients in either group, indicating there was no significant difference with regard to neurologic recovery between the two groups (p>0.05 Fisher''s exact test).

Conclusion

Intervertebral disc damage is a common characteristic in type B and C spinal fracture-dislocation injuries. The damaged intervertebral disc should be removed and substituted with a bone graft because reserving the damaged disc in situ increases the risk of treatment failure.  相似文献   

6.

Background

Short-segment pedicle screw instrumentation (SSPI) is used for unstable burst fractures to correct deformity and stabilize the spine for fusion. However, pedicle screw loosening, pullout, or breakage often occurs due to the large moment applied during spine motion, leading to poor outcomes. The purpose of this study was to test the ability of a newly designed device, the Trans-Endplate Pedicle Pillar System (TEPPS), to enhance SSPI rigidity and decrease the screw bending moment with a simple posterior approach.

Methods

Six human cadaveric spines (T11-L3) were harvested. A burst fracture was created at L1, and the SSPI (Moss Miami System) was used for SSPI fixation. Strain gauge sensors were mounted on upper pedicle screws to measure screw load bearing. Segmental motion (T12-L2) was measured under pure moment of 7.5 Nm. The spine was tested sequentially under 4 conditions: intact; first SSPI alone (SSPI-1); SSPI+TEPPS; and second SSPI alone (SSPI-2).

Results

SSPI+TEPPS increased fixation rigidity by 41% in flexion/extension, 28% in lateral bending, and 37% in axial rotation compared with SSPI-1 (P<0.001), and it performed even better compared to SSPI-2 (P<0.001 for all). Importantly, the bending moment on the pedicle screws for SSPI+TEPPS was significantly decreased 63% during spine flexion and 47% in lateral bending (p<0.001).

Conclusion

TEPPS provided strong anterior support, enhanced SSPI fixation rigidity, and dramatically decreased the load on the pedicle screws. Its biomechanical benefits could potentially improve fusion rates and decrease SSPI instrumentation failure.  相似文献   

7.

Objective

For multi-level spondylolysis patients, surgeons commonly choose to fix all the segments with pars interarticularis defect even those without slippage and not responsible for clinical symptoms. In this study, we tried to study the necessity of the preventative long-segment surgery for the defected segment without slippage in treatment of multi-level spondylolysis patients from a biomechanical perspective.

Method

We established a bi-level spondylolysis model with pars defects at L4 and L5 segments, and simulated posterior lumbar interbody fusion (PLIF) and pedicle screw fixation at L5-S1 level. Then we compared the biomechanical changes at L4 segment before and after surgery in neutral, flexion, extension, lateral bending and axial rotation position.

Results

The stress on L4 pars interarticularis was very similar before and after surgery, and reached the highest in axial rotation. The L3-L4 intradiscal pressure was almost the same, while L4-L5 intradiscal pressure changed a little in lateral bending (increase from 1.993 to 2.160 MPa) and axial rotation (decrease from 1.639 to 1.307 MPa) after surgery. The PLIF surgery caused a little increase of range of motion at adjacent L4-L5 and L3-L4 levels, but the change is very tiny (1 degree).

Conclusion

The PLIF surgery will not cause significant biomechanical change at adjacent segment with pars defect in multi-level spondylolysis. On the contrary, excessive long-segment surgery will damage surrounding soft tissues which are important for maintaining the stability of spine. So a preventative long-segment surgery is not necessary for multi-level spondylolysis as long as there are no soft tissue degeneration signs at adjacent level.  相似文献   

8.
The purpose of our study is to develop and validate three-dimensional finite element models of transforaminal lumbar interbody fusion, and explore the most appropriate method of fixation and fusion by comparing biomechanical characteristics of different fixation method. We developed four fusion models: bilateral pedicle screws fixation with a single cage insertion model (A), bilateral pedicle screws fixation with two cages insertion model (B), unilateral pedicle screws fixation with a single cage insertion model (C), and unilateral pedicle screws fixation with two cages insertion model (D); the models were subjected to different forces including anterior bending, posterior extension, left bending, right bending, rotation, and axial compressive. The von Mises stress of the fusion segments on the pedicle screw and cages was recorded. Angular variation and stress of pedicle screw and cage were compared. There were differences of Von Mises peak stress among four models, but were within the range of maximum force. The angular variation in A, B, C, and D decreased significantly compared with normal. There was no significant difference of angular variation between A and B, and C and D. Bilateral pedicle screws fixation had more superior biomechanics than unilateral pedicle screws fixation. In conclusion, the lumbar interbody fusion models were established using varying fixation methods, and the results verified that unilateral pedicle screws fixation with a single cage could meet the stability demand in minimal invasive transforaminal interbody fusion.  相似文献   

9.

Background

There have been few studies comparing the clinical and radiographic outcomes between the Dynesys dynamic stabilization system and posterior lumbar interbody fusion (PLIF). The objective of this study is to compare the clinical and radiographic outcomes of Dynesys and PLIF for lumbar degenerative disease.

Methods

Of 96 patients with lumbar degenerative disease included in this retrospectively analysis, 46 were treated with the Dynesys system and 50 underwent PLIF from July 2008 to March 2011. Clinical and radiographic outcomes were evaluated. We also evaluated the occurrence of radiographic and symptomatic adjacent segment degeneration (ASD).

Results

The mean follow-up time in the Dynesys group was 53.6 ± 5.3 months, while that in the PLIF group was 55.2 ± 6.8 months. At the final follow-up, the Oswestry disability index and visual analogue scale score were significantly improved in both groups. The range of motion (ROM) of stabilized segments in Dynesys group decreased from 7.1 ± 2.2° to 4.9 ± 2.2° (P < 0.05), while that of in PLIF group decreased from 7.3 ± 2.3° to 0° (P < 0.05). The ROM of the upper segments increased significantly in both groups at the final follow-up, the ROM was higher in the PLIF group. There were significantly more radiographic ASDs in the PLIF group than in the Dynesys group. The incidence of complications was comparable between groups.

Conclusions

Both Dynesys and PLIF can improve the clinical outcomes for lumbar degenerative disease. Compared to PLIF, Dynesys stabilization partially preserves the ROM of the stabilized segments, limits hypermobility in the upper adjacent segment, and may prevent the occurrence of ASD.  相似文献   

10.

Study Design

A comparable retrospective study.

Object

To compare the clinical outcomes of surgical treatment by posterior only and anterior video-assisted thoracoscopic surgery for thoracic spinal tuberculosis (TSTB).

Method

145 patients with TSTB treated by two different surgical procedures in our institution from June 2001 to June 2014 were studied. All cases were retrospectively analyzed and divided into two groups according to the given treatments: 75 cases (32F/43M) in group A performed single-stage posterior debridement, transforaminal thoracic interbody fusion and instrumentation, and 70 cases (30F/40M) in group B underwent anterior video-assisted thoracoscopic surgery (VATS). Clinical and radiographic results in the two groups were analyzed and compared.

Results

Patients in group A and B were followed up for an average of 4.6±1.8, 4.4±1.2 years, respectively. There was no statistically significant difference between groups in terms of the operation time, blood loss, bony fusion, neurological recovery and the correction angle of kyphotic deformity (P>0.05). Fewer pulmonary complications were observed in group A. Good clinical outcomes were achieved in both groups.

Conclusions

Both the anterior VATS and posterior approaches can effectively treat thoracic tuberculosis. Nevertheless, the posterior approach procedure obtained less morbidity and complications than the other.  相似文献   

11.
BACKGROUND: Interbody arthrodesis is employed in the lumbar spine to eliminate painful motion and achieve stability through bony fusion. Bone grafts, metal cages, composite spacers, and growth factors are available and can be placed through traditional open techniques or minimally invasively. Whether placed anteriorly, posteriorly, or laterally, insertion of these implants necessitates compromise of the anulus--an inherently destabilizing procedure. A new axial percutaneous approach to the lumbosacral spine has been described. Using this technique, vertical access to the lumbosacral spine is achieved percutaneously via the presacral space. An implant that can be placed across a motion segment without compromise to the anulus avoids surgical destabilization and may be advantageous for interbody arthrodesis. The purpose of this study was to evaluate the in vitro biomechanical performance of the axial fixation rod, an anulus sparing, centrally placed interbody fusion implant for motion segment stabilization. METHOD OF APPROACH: Twenty-four bovine lumbar motion segments were mechanically tested using an unconstrainedflexibility protocol in sagittal and lateral bending, and torsion. Motion segments were also tested in axial compression. Each specimen was tested in an intact state, then drilled (simulating a transaxial approach to the lumbosacral spine), then with one of two axial fixation rods placed in the spine for stabilization. The range of motion, bending stiffness, and axial compressive stiffness were determined for each test condition. Results were compared to those previously reported for femoral ring allografts, bone dowels, BAK and BAK Proximity cages, Ray TFC, Brantigan ALIF and TLIF implants, the InFix Device, Danek TIBFD, single and double Harms cages, and Kaneda, Isola, and University plating systems. RESULTS: While axial drilling of specimens had little effect on stiffness and range of motion, specimens implanted with the axial fixation rod exhibited significant increases in stiffness and decreases in range of motion relative to intact state. When compared to existing anterior, posterior, and interbody instrumentation, lateral and sagittal bending stiffness of the axial fixation rod exceeded that of all other interbody devices, while stiffness in extension and axial compression were comparable to plate and rod constructs. Torsional stiffness was comparable to other interbody constructs and slightly lower than plate and rod constructs. CONCLUSIONS: For stabilization of the L5-S1 motion segment, axial placement of implants offers potential benefits relative to traditional exposures. The preliminary biomechanical data from this study indicate that the axial fixation rod compares favorably to other devices and may be suitable to reduce pathologic motion at L5-S1, thus promoting bony fusion.  相似文献   

12.

Study Strategy

A retrospective clinic study.

Purpose

To evaluate the efficacy of conservative and surgical treatment for lumbosacral tuberculosis.

Methods

This study retrospectively reviewed 53 patients with lumbosacral tuberculosis who were treated in our institution between January 2005 and January 2011. There were 29 males and 24 females with average ages of 37.53 ± 17.28 years (range 6–72 years). 11 patients were given only anti-TB drugs; the remainder underwent anterior debridement, interbody fusion with and without instrumentation, or one-stage anterior debridement combined with posterior instrumentation. Outcome data for these patients included neurologic status, lumbosacral angle, erythrocyte sedimentation rate value(ESR) and C-reactive protein value(CRP) were assessed before and after treatment.

Results

The mean lumbosacral angles were 23.00°± 2.90°in the conservatively treated patients and 22.36°± 3.92o in the surgically treated patients. At the final follow-up, this had improved to 24.10o ± 2.96°in the conservatively treated patients and 28.13° ± 1.93°in the surgically treated patients (all P < 0.05). There were statistically significant differences before and after treatment in terms of ESR and CRP (all P < 0.05). All patients achieved bone fusion. The mean follow-up period was 32.34 ± 8.13 months (range 18 to 55 months). The neurological deficit did not worsen in any of the patients.

Conclusions

It has been proven that conservative and surgical treatments are safe and effective and produce good clinical outcomes for patients with lumbosacral tuberculosis. The advantages of operation include thoroughness of debridement, decompression of the spinal cord, and adequate spinal stabilization.  相似文献   

13.

Purpose

This study aims to investigate the feasibility of a novel lumbar approach named extraforaminal lumbar interbody fusion (ELIF), a newly emerging minimally invasive technique for treating degenerative lumbar disorders, using a digitalized simulation and a cadaveric study.

Methods

The ELIF surgical procedure was simulated using the Mimics surgical simulator and included dissection of the superior articular process, dilation of the vertebral foramen, and placement of pedicle screws and a cage. ELIF anatomical measures were documented using a digitalized technique and subsequently validated on fresh cadavers.

Results

The use of the Mimics allowed for the vivid simulation of ELIF surgical procedures, while the cadaveric study proved the feasibility of this novel approach. ELIF had a relatively lateral access approach that was located 8–9 cm lateral to the median line with an access depth of approximately 9 cm through the intermuscular space. Dissection of the superior articular processes could fully expose the target intervertebral discs and facilitate a more inclined placement of the pedicle screws and cage with robust enhancement.

Conclusions

According to the computer-based simulation and cadaveric study, it is feasible to perform ELIF. Further research including biomechanical study is needed to prove ELIF has a superior ability to preserve the posterior tension bands of the spinal column, with similar effects on spinal decompression, fixation, and fusion, and if it can enhance post-fusion spinal stability and expedites postoperative recovery.  相似文献   

14.

Study design

A retrospective clinical study.

Objective

To evaluate the clinical efficacy of the surgical treatment of noncontiguous spinal tuberculosis (NSTB), and to discuss its therapeutic strategies.

Methods

We performed a retrospective review of clinical and radiographic data that were prospectively collected on 550 consecutive spinal tubercular patients including 27 patients who were diagnosed and treated as NSTB in our institution from June 2005 to June 2011. Apart from 4 patients being treated conservatively, the remainder received surgery by posterior transforaminal debridement, interbody fusion with instrumentation, posterior instrumentation and anterior debridement with fusion in a single or two-stage operation. The clinical outcomes were evaluated before and after treatment in terms of hematologic and radiographic examinations, bone fusion and neurologic status. The Oswestry Disability Index score was determined before treatment and at the last follow-up visit.

Results

23 patients (15 M/8F), averaged 44.6±14.2 years old (range, 19 to 70 yd), who received surgical treatment, were followed up after surgery for a mean of 52.5±19.5 months (range, 24 to 72 months). The kyphotic angle was changed significantly between pre- and postoperation (P<0.05). The mean amount of correction was 12.6±7.2 degrees, with a small loss of correction at last follow-up. All patients achieved solid bone fusion. No patients with neurological deficit deteriorated postoperatively. Neither mortalities nor any major complications were found. There was a significant difference of Oswestry Disability Index scores between preoperation and the final follow-up.

Conclusion

The outcomes of follow-up showed that posterior and posterior-anterior surgical treatment methods were both viable surgical options for NSTB. Posterior transforaminal debridement, interbody fusion and posterior instrumentation, as a less invasive technique, was feasible and effective to treat specific tubercular foci.  相似文献   

15.

Objective

To test whether the phantom limb awareness could be altered by observing mirror reflection-induced visual feedback (MVF) in unilateral forearm amputees.

Methods

Ten unilateral forearm amputees were asked to perform bilateral (intact and phantom) synchronous wrist motions with and without MVF. During wrist motion, electromyographic activities in the extensor digitorum longus (EDL) and flexor carpi radialis muscles (FCR) were recorded with bipolar electrodes. Degree of wrist range of motion (ROM) was also recorded by electrogoniometry attached to the wrist joint of intact side. Subjects were asked to answer the degree of attainment of phantom limb motion using a visual analog scale (VAS: ranging from 0 (hard) to 10 (easy)).

Results

VAS and ROM were significantly increased by utilizing MVF, and the extent of an enhancement of the VAS and wrist ROM was positively correlated (r = 0.72, p<0.05). Although FCR EMG activity also showed significant enhancement by MVF, this was not correlated with the changes of VAS and ROM. Interestingly, while we found negative correlation between EDL EMG activity and wrist ROM, MVF generally affected to be increasing both EDL EMG and ROM.

Conclusions

Although there was larger extent of variability in the effect of MVF on phantom limb awareness, MVF has a potential to enhance phantom limb awareness, in case those who has a difficulty for the phantom limb motion. The present result suggests that the motor command to the missing limb can be re-activated by an appropriate therapeutic strategy such as mirror therapy.  相似文献   

16.

Background Context

Animals are commonly used to model the human spine for in vitro and in vivo experiments. Many studies have investigated similarities and differences between animals and humans in the lumbar and thoracic vertebrae. However, a quantitative anatomic comparison of calf, pig, and human cervical spines has not been reported.

Purpose

To compare fundamental structural similarities and differences in vertebral bodies from the cervical spines of commonly used experimental animal models and humans.

Study Design

Anatomical morphometric analysis was performed on cervical vertebra specimens harvested from humans and two common large animals (i.e., calves and pigs).

Methods

Multiple morphometric parameters were directly measured from cervical spine specimens of twelve pigs, twelve calves and twelve human adult cadavers. The following anatomical parameters were measured: vertebral body width (VBW), vertebral body depth (VBD), vertebral body height (VBH), spinal canal width (SCW), spinal canal depth (SCD), pedicle width (PW), pedicle depth (PD), pedicle inclination (PI), dens width (DW), dens depth (DD), total vertebral width (TVW), and total vertebral depth (TVD).

Results

The atlantoaxial (C1–2) joint in pigs is similar to that in humans and could serve as a human substitute. The pig cervical spine is highly similar to the human cervical spine, except for two large transverse processes in the anterior regions ofC4–C6. The width and depth of the calf odontoid process were larger than those in humans. VBW and VBD of calf cervical vertebrae were larger than those in humans, but the spinal canal was smaller. Calf C7 was relatively similar to human C7, thus, it may be a good substitute.

Conclusion

Pig cervical vertebrae were more suitable human substitutions than calf cervical vertebrae, especially with respect to C1, C2, and C7. The biomechanical properties of nerve vascular anatomy and various segment functions in pig and calf cervical vertebrae must be considered when selecting an animal model for research on the spine.  相似文献   

17.

Background

Anterior plate fusion is an effective procedure for the treatment of cervical spinal diseases but is accompanied by a high incidence of postoperative dysphagia. A zero profile (Zero-P) spacer is increasingly being used to reduce postoperative dysphagia and other potential complications associated with surgical intervention. Studies comparing the Zero-P spacer and anterior plate have reported conflicting results.

Methodology

A meta-analysis was conducted to compare the safety, efficacy, radiological outcomes and complications associated with the use of a Zero-P spacer versus an anterior plate in anterior cervical spine fusion for the treatment of cervical spinal disease. We comprehensively searched PubMed, Embase, the Cochrane Library and other databases and performed a meta-analysis of all randomized controlled trials (RCTs) and prospective or retrospective comparative studies assessing the two techniques.

Results

Ten studies enrolling 719 cervical spondylosis patients were included. The pooled data showed significant differences in the operation time [SMD = –0.58 (95% CI = −0.77 to 0.40, p < 0.01)] and blood loss [SMD = −0.40, 95% CI (−0.59 to –0.21), p < 0.01] between the two groups. Compared to the anterior plate group, the Zero-P group exhibited a significantly improved JOA score and reduced NDI and VAS. However, anterior plate fusion had greater postoperative segmental and cervical Cobb’s angles than the Zero-P group at the last follow-up. The fusion rate in the two groups was similar. More importantly, the Zero-P group had a lower incidence of earlier and later postoperative dysphagia.

Conclusions

Compared to anterior plate fusion, Zero-P is a safer and effective procedure, with a similar fusion rate and lower incidence of earlier and later postoperative dysphagia. However, the results of this meta-analysis should be accepted with caution due to the limitations of the study. Further evaluation and large-sample RCTs are required to confirm and update the results of this study.  相似文献   

18.

Objective

To evaluate the dynamic change of CD34 level during the survival process of narrow pedicle flaps.

Methods

Twenty-five white pigs were randomly and equally divided into 5 experimental groups. Five different type of narrow pedicle with different length-to-width ratio were employed, and each type of narrow pedicle was covered with 5 different size random flaps and which was classified into A, B, C, D and E for 5 groups. Group A was control group. Each type narrow pedicle with 5 different skin flaps were implanted onto the back of the pigs along the midline of back with a reverse direction. A 0.3 cm×0.3 cm full thickness skin flap in the middle of distal segment was collected and on 3rd, 5th, 7th and 14th days of post-operation. The expression of CD34 was measured by immunohistochemistry and enzyme-linked immunosorbent (ELISA).

Results

Histological examination showed that with the increasing of length-to-width ratio of the narrow pedicle skin flaps, the expression of CD34 increased in the skin flaps. Increased level of CD34 was found on 3rd day post-operation, and the peak expression was found on 7th day. Persistent high level of CD34 was found until 14th day.

Conclusion

Increased CD34 level in the distal skin flap, there is the association between CD34 level and ischemia injury. Moreover, CD34 expression plays an important role during the repair processes of pedicle flaps.  相似文献   

19.

Background

Postural control during rapid movements may be impaired due to musculoskeletal pain. The purpose of this study was to investigate the effect of experimental knee-related muscle pain on the center of pressure (CoP) displacement in a reaction time task condition.

Methods

Nine healthy males performed two reaction time tasks (dominant side shoulder flexion and bilateral heel lift) before, during, and after experimental pain induced in the dominant side vastus medialis or the tibialis anterior muscles by hypertonic saline injections. The CoP displacement was extracted from the ipsilateral and contralateral side by two force plates and the net CoP displacement was calculated.

Results

Compared with non-painful sessions, tibialis anterior muscle pain during the peak and peak-to-peak displacement for the CoP during anticipatory postural adjustments (APAs) of the shoulder task reduced the peak-to-peak displacement of the net CoP in the medial-lateral direction (P<0.05). Tibialis anterior and vastus medialis muscle pain during shoulder flexion task reduced the anterior-posterior peak-to-peak displacement in the ipsilateral side (P<0.05).

Conclusions

The central nervous system in healthy individuals was sufficiently robust in maintaining the APA characteristics during pain, although the displacement of net and ipsilateral CoP in the medial-lateral and anterior-posterior directions during unilateral fast shoulder movement was altered.  相似文献   

20.
Previous studies have compared the effects of different interbody fusion approaches on biomechanical responses of the lumbar spine to static loadings. However, very few have dealt with the whole body vibration (WBV) condition that is typically present in vehicles. This study was designed to determine the biomechanical differences among anterior, posterior and transforaminal lumbar interbody fusion (ALIF, PLIF and TLIF) under vertical WBV. A previously developed and validated finite element (FE) model of the intact L1–sacrum human lumbar spine was modified to simulate ALIF, PLIF and TLIF with bilateral pedicle screw fixation at L4–L5. Comparative studies on dynamic responses to the axial cyclic loading in these developed models were conducted. The results showed that at the fused L4–L5 level, dynamic responses of the von-Mises stress in L4 inferior and L5 superior endplates for the ALIF, PLIF and TLIF models were increased compared with the intact model. The endplate stresses in the TLIF model were lower than in the ALIF and PLIF models, but the TLIF generated greater stresses in the screws and rods compared with the ALIF and PLIF. At other levels, a decrease in dynamic responses of the disc bulge, annulus stress and intradiscal pressure was observed in all the fusion models compared with the intact one, but there was no obvious difference in these dynamic responses among the ALIF, PLIF and TLIF models. These findings might be useful in understanding vibration characteristics of the whole lumbar spine after different types of fusion surgery.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号