首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
(E)-5-(2-Bromovinyl)-2′-deoxyuridine is an antiviral drug used for treatment of infections with Herpes simplex virus type 1 as well as Varicella zoster virus. Two fast methods for the determination of the drug and its metabolite in plasma and urine by capillary electrophoresis have been developed. The plasma method can be used for measurement of total as well as unbound drug and metabolite. Plasma and urine samples are prepared for measuring by liquid/liquid extraction resulting in a limit of quantification of 40 ng/ml for total and 10 ng/ml for free BVdU in plasma and 170 ng/ml in urine. Inter- as well as intra-day precision were found to be better than 10% and both methods have been used for drug monitoring of patients.  相似文献   

2.
A rapid method for the quantification of amiodarone and desethylamiodarone in animal plasma using high-performance liquid chromatography combined with UV detection (HPLC-UV) is presented. The sample preparation includes a simple deproteinisation step with acetonitrile. In addition, a sensitive method for the quantification of amiodarone and desethylamiodarone in horse plasma and urine using high-performance liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) is described. The sample preparation includes a solid-phase extraction (SPE) with a SCX column. Tamoxifen is used as an internal standard for both chromatographic methods. Chromatographic separation is achieved on an ODS Hypersil column using isocratic elution with 0.01% diethylamine and acetonitrile as mobile phase for the HPLC-UV method and with 0.1% formic acid and acetonitrile as mobile phase for the LC-MS/MS method. For the HPLC-UV method, good linearity was observed in the range 0-5 microg ml(-1), and in the range 0-1 microg ml(-1) for the LC-MS/MS method. The limit of quantification (LOQ) was set at 50 and 5 ng ml(-1) for the HPLC-UV method and the LC-MS/MS method, respectively. For the UV method, the limit of detection (LOD) was 15 and 10 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The LODs of the LC-MS/MS method in plasma were much lower, i.e. 0.10 and 0.04 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The LODs obtained for the urine samples were 0.16 and 0.09 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The methods were shown to be of use in horses. The rapid HPLC-UV method was used for therapeutic drug monitoring after amiodarone treatment, while the LC-MS/MS method showed its applicability for single dose pharmacokinetic studies.  相似文献   

3.
A bioanalytical method for the analysis of artesunate and its metabolite dihydroartemisinin in human plasma using high throughput solid-phase extraction in the 96-wellplate format and liquid chromatography coupled to positive tandem mass spectroscopy has been developed and validated. The method was validated according to published FDA guidelines and showed excellent performance. The within-day and between-day precisions expressed as RSD, were lower than 7% at all tested concentrations including the lower limit of quantification. Using 50 microl plasma the calibration range was 1.19-728 ng/ml with a limit of detection at 0.5 ng/ml for artesunate and 1.96-2500 ng/ml with a limit of detection at 0.6 ng/ml for dihydroartemisinin. Using 250 microl of plasma sample the lower limit of quantification was decreased to 0.119 ng/ml for artesunate and 0.196 ng/ml dihydroartemisinin. Validation of over-curve samples in plasma ensured that accurate estimation would be possible with dilution if samples went outside the calibration range. The method was free from matrix effects as demonstrated both graphically and quantitatively.  相似文献   

4.
An isocratic online-enrichment HPLC-assay was developed allowing for the simple and fast separation and quantitation of STI-571 and its main metabolite N-desmethyl-STI (N-DesM-STI) in plasma, urine, cerebrospinal fluid (CSF), culture media and cell preparations in various concentrations using UV-detection at 260 nm. The analytical procedure consists of an online concentration of STI-571 and N-DesM-STI in the HPLC system followed by the elution on a ZirChrom-PBD analytical column. Time of analysis is 40 min including the enrichment time of 5 min. The detection limit is 10 ng/ml in plasma, CSF, culture medium (RPMI) and 25 ng/ml in urine for both STI-571 and N-DesM-STI. The intra-day precision, as expressed by the coefficient of variation (CV), in plasma samples ranges between 1.74 and 8.60% for STI-571 and 1.45 and 8.87% for N-DesM-STI. The corresponding values for urine measurements are 2.17-7.54% (STI-571) and 1.31-9.51% (N-DesM-STI). The inter-day precision analyzed over a 7-month time period was 8.31% (STI-571) or 6.88% (N-DesM-STI) and 16.45% (STI-571) or 14.83% (N-DesM-STI) for a concentration of 1000 ng/ml in plasma and 750 ng/ml in urine, respectively. Moreover, we demonstrate that with an alternative, but more time and labor consuming sample preparation and the implementation of electrochemical detection, a detection limit < 10 ng/ml can be achieved. The method described was used to perform pharmacokinetic measurements of STI-571 and N-desmethyl-STI in patient samples and for kinetic measurements of intracellular STI-571 and N-DesM-STI following in vitro incubation.  相似文献   

5.
An enantioseparation of the antipsychotic drug butaclamol in human plasma by high-performance liquid chromatography (HPLC) with solid phase extraction is presented. The separation was achieved on the vancomycin macrocyclic antibiotic chiral stationary phase (CSP) Chirobiotic V with a polar ionic mobile phase (PIM) consisting of methanol : glacial acetic acid : triethylamine (100:0.2:0.05, v/v/v) at a flow rate of 0.5 ml/min. The detection wavelength was 262 nm. Bond Elut C18 solid phase extraction cartridges were used in the sample preparation of butaclamol samples from plasma. The method was validated over the range of 100-3,000 ng/ml for each enantiomer concentration (R(2) > 0.999). Recoveries for (+)- and (-)-butaclamol were in the range of 94-104% at the 300-2,500 ng/ml level. The method proved to be precise (within-run precision ranged from 1.1-2.6% and between-run precision ranged from 1.9-3.2%) and accurate (within-run accuracies ranged from 1.5-5.8% and between-run accuracies ranged from 2.7-7.7%). The limit of quantitation (LOQ) and limit of detection (LOD) for each enantiomer in human plasma were 100 ng/ml and 50 ng/ml, respectively.  相似文献   

6.
The characteristics of automated on-line solid phase extraction with liquid chromatography-mass spectrometry (SPE-LC-MS) are very amenable for flexibility and throughput in therapeutic drug monitoring (TDM). We demonstrate this concept of automated, on-line SPE-LC-MS for the analysis of clozapine and metabolites (desmethylclozapine and clozapine-N-oxide) in serum. Method development, optimisation and validation are described and a comparison with previously published methods for the determination of clozapine and metabolites in serum and plasma is made. Optimisation of chromatographic and SPE conditions for increased throughput resulted in SPE-LC-MS cycle times of only about 2.2 min, demonstrating the great potential of automated on-line SPE-LC-MS for TDM. The new method is shown to be clearly favourable, in particular in terms of ease of sample handling, throughput and detection limits. Recovery is essentially quantitative. Detection limits are at about 0.15-0.3 ng ml(-1), depending on the ionisation source used. Calibration follows a quadratic model for clozapine and its N-oxide and a linear model for the desmethyl metabolite (all cases: R > 0.99). Accuracy, evaluated at three concentration levels spanning the whole therapeutic range, shows that bias is less than 10%. Precision (intra - and inter assay) ranges from about 5% R.S.D. at the high end of the therapeutic range (700-1,000 ng ml(-1)) to about 20% R.S.D. (OECD defined limit) at the lower limit of quantitation ( approximately 50 ng ml(-1)). The lower limit of quantitation is well below the low end of the therapeutic range at 350 ng ml(-1).  相似文献   

7.
Gemcitabine (dFdC) is a pyrimidine antimetabolite with broad spectrum activity against tumors. In this paper, a normal-phase high-performance liquid chromatographic method was developed for the determination of the parent drug (dFdC) and its metabolite (dFdU) in human plasma. The described sample preparation procedure for determination of dFdC and dFdU is rapid, sensitive, reproducible and simple. The linear regression equations obtained by least square regression method, were area under the curve=0.0371 concentration (ng ml(-1))+192.53 and 1.05.10(-4) concentration (ng ml(-1))-1.2693 for dFdC and dFdU, respectively. The assay for dFdC and dFdU described in the present report has been applied to plasma samples from a bladder cancer patient.  相似文献   

8.
Procarbazine is a cytotoxic chemotherapeutic agent used in the treatment of lymphomas and brain tumors. Its pharmacokinetic behavior remains poorly understood even though more than 30 years have elapsed since the drug was approved for clinical use. To characterize the pharmacokinetics of procarbazine in brain cancer patients during a phase I trial, a method for determining the drug in human plasma by reversed-phase high-performance liquid chromatography (HPLC) with electrospray ionization mass spectrometry (ESI-MS) was developed and thoroughly validated. Plasma samples were prepared for analysis by precipitating proteins with trichloroacetic acid and washing the protein-free supernatant with methyl tert-butyl ether to remove excess acid. The solution was separated on a Luna C-18 analytical column using methanol-25 mM ammonium acetate buffer, pH 5.1 (22:78, v/v) as the mobile phase at 1.0 ml/min. A single-quadrupole mass spectrometer with an electrospray interface was operated in the selected-ion monitoring mode to detect the [M+H](+) ions at m/z 222.2 for procarbazine and at m/z 192.1 for the internal standard (3-dimethylamino-2-methylpropiophenone). Procarbazine and the internal standard eluted as sharp, symmetrical peaks with retention times (mean+/-S.D.) of 6.3+/-0.1 and 9.9+/-0.3 min, respectively. Calibration curves of procarbazine hydrochloride in human plasma at concentrations ranging from 0.5 to 50 ng/ml exhibited excellent linearity. The mean absolute recovery of the drug from plasma was 102.9+/-1.0%. Using a sample volume of 150 microl, procarbazine was determined at the 0.5 ng/ml (1.9 nM) lower limit of quantitation with a mean accuracy of 105.2% and an interday precision of 3.60% R.S.D. on 11 different days over 5 weeks. During this same time interval, the between-day accuracy for determining quality control solutions of the drug in plasma at concentrations of 2.0, 15 and 40 ng/ml ranged from 97.5 to 98.2% (mean+/-S.D., 97.9+/-0.4%) and the precision was 3.8-6.2% (mean+/-S.D., 5.1+/-1.2%). Stability characteristics of the drug were thoroughly evaluated to establish appropriate conditions to process, store and prepare clinical specimens for chromatographic analysis without inducing significant chemical degradation. The sensitivity achieved with this assay permitted the plasma concentration-time profile of the parent drug to be accurately defined following oral administration of standard doses to brain cancer patients.  相似文献   

9.
Mianserin is a tetracyclic antidepressant drug and administered as racemate of R (-) and S (+) mianserin hydrochloride in a dose of 30-90 mg/day in divided doses. Liquid chromatography-mass spectroscopy (LC-MS) is a tool, which is widely used for determination of drug and their metabolites in biological fluids because of its high sensitivity and precision. Here we describe a liquid chromatography mass spectroscopy method for simultaneous determination of mianserin and its metabolite, N-desmethylmianserin, from human plasma using a liquid-liquid extraction with hexane:isoamylalcohol (98:2) and back extraction with 0.005 M formic acid solution. This method is specific and linear over the concentration range of 1.00-60.00 ng/ml for mianserin and 0.50-14.00 ng/ml for N-desmethylmianserin in human plasma. The lowest limits of quantification (LLQ) is 1.00 ng/ml for mianserin and 0.50 ng/ml for N-desmethylmianserin. Intraday and interday precision (%C.V.) is <10% for both mianserin and N-desmethylmianserin. The accuracy ranges from 94.44 to 112.33% for mianserin and 91.85-100.13% for N-desmethylmianserin. The stability studies showed that mianserin and N-desmethylmianserin in human plasma are stable during short-term period for sample preparation and analysis. The method was used to assay mianserin and its metabolite, N-desmethylmianserin, in human plasma samples obtained from subjects who had been given an oral tablet of 30 mg of mianserin.  相似文献   

10.
A sensitive method for the quantification of lidocaine and its metabolites, monoethylglycinexylidide (MEGX) and glycinexylidide (GX), in animal plasma using high-performance liquid chromatography combined with electrospray ionization mass spectrometry is described. The sample preparation includes a liquid-liquid extraction with methyl tert-butylmethyl ether after addition of 2M sodium hydroxide. Ethylmethylglycinexylidide (EMGX) is used as an internal standard. For chromatographic separation, an ODS Hypersil column was used. Isocratic elution was achieved with 0.01 M ammonium acetate and acetonitrile as mobile phases. Good linearity was observed in the range of 2.5-1000 ng ml(-1) for lidocaine in both dog and horse plasma. For MEGX, linear calibration curves were obtained in the range of 5-1000 ng ml(-1) and 20-1000 ng ml(-1) for dog and horse plasma, respectively. In dog and horse plasma good linearity was observed in the range of 200-1500 ng ml(-1) for GX. The limit of quantification (LOQ) in dog plasma for lidocaine, MEGX and GX was set at 2.5 ng ml(-1), 20 ng ml(-1) and 200 ng ml(-1), respectively. For horse plasma a limit of quantification of 2.5 ng ml(-1), 5 ng ml(-1) and 200 ng ml(-1) was achieved for lidocaine, MEGX and GX, respectively. In dog plasma, the limit of detection (LOD) was found to be 0.8 ng ml(-1), 2.3 ng ml(-1) and 55 ng ml(-1) for lidocaine, MEGX and GX, respectively. In horse plasma the LOD's found for lidocaine, MEGX and GX, were 1.1 ng ml(-1), 0.5 ng ml(-1) and 13 ng ml(-1), respectively. The method was shown to be of use in pharmacokinetic studies after application of a transdermal patch in dogs and after an intravenous infusion in horses.  相似文献   

11.
Two drug assays were developed and applied to assess the enantiomeric composition of an insulin sensitizer drug in plasma after administration of its racemate to man, and in human and animal plasma and serum samples generated after in vitro experiments. The sample preparation for the assays consisted either of protein precipitation and column-switching, or liquid-liquid extraction and direct injection. Subsequently, both assays employed chiral HPLC coupled to atmospheric pressure ionization mass spectrometry. An interconversion of the racemate to a mixture enriched with the (+)-enantiomer could be confirmed for all species and biological matrices. The individual enantiomers could be quantified in the concentration range 0.5-500 ng/ml, starting with a 100-microl plasma aliquot. Inter- and intra-assay precision and accuracy were in the range 0.1-7.9 and 88.8-106.0%, respectively. Run times of 5 min for a single sample allows the analysis of more than 200 samples overnight.  相似文献   

12.
A high throughput bioanalytical assay for the determination of lumefantrine in plasma has been developed and validated extensively. The within-day precisions for lumefantrine were 5.2, 3.5 and 2.5% at 200, 2000 and 15000 ng/mL, respectively. The between-day precisions were 4.0, 2.8 and 3.1% at 200, 2000 and 15000 ng/mL, respectively. The lower limits of quantification (LLOQ) and the limits of detection (LOD) were 25 and 10 ng/mL, respectively using 0.250 mL plasma. The average recovery of lumefantrine was 85% and independent upon concentration. The use of 96-well plate format and short chromatographic run has increased the daily sample throughput four times. The assay is particularly suitable for large therapeutic drug monitoring studies using day 7 sampling.  相似文献   

13.
Following oral administration of the prodrug nabumetone, the major metabolite 6-methoxy-2-naphthylacetic acid (6-MNA) was determined in human plasma. Minimal sample preparation was followed by reversed-phase liquid chromatography and UV detection, affording high sample throughput. The lower limit of quantification (LLOQ) was 70 ng/ml, at a signal-to-noise ratio of 8:1. The assay method displayed good correlation (r=0.997), and can be readily employed in pharmacokinetic and bioequivalence studies.  相似文献   

14.
An HPLC method has been developed and validated for the determination of spironolactone, 7 alpha-thiomethylspirolactone and canrenone in paediatric plasma samples. The method utilises 200 microl of plasma and sample preparation involves protein precipitation followed by Solid Phase Extraction (SPE). Determination of standard curves of peak height ratio (PHR) against concentration was performed by weighted least squares linear regression using a weighting factor of 1/concentration2. The developed method was found to be linear over concentration ranges of 30-1000 ng/ml for spironolactone and 25-1000 ng/ml for 7 alpha-thiomethylspirolactone and canrenone. The lower limit of quantification for spironolactone, 7 alpha-thiomethylspirolactone and canrenone were calculated as 28, 20 and 25 ng/ml, respectively. The method was shown to be applicable to the determination of spironolactone, 7 alpha-thiomethylspirolactone and canrenone in paediatric plasma samples and also plasma from healthy human volunteers.  相似文献   

15.
In the present studies, to give momentum to traditionally low throughput pharmacokinetic screening, a bioanalytical method based on the concept of sample pooling for simultaneous bioanalysis of multiple compounds is discussed. A sensitive, selective, specific and rapid HPLC/ESI-MS/MS assay method was developed and validated for the simultaneous quantitation of three novel trioxane antimalarials (99-357, 99-408 and 99-411) in rat plasma using trioxane analogue as internal standard. The suitably validated bioanalytical method was then further extrapolated to rabbit and monkey plasma by performing partial validation. Extraction from the plasma involves a simple two-step liquid-liquid extraction with n-hexane. The analytes were chromatographed on a cyano column by isocratic elution with acetonitrile:ammonium acetate buffer (pH 6) (85:15, v/v) and analyzed by mass spectrometry in multiple reaction-monitoring (MRM) mode. The chromatographic run time was 5.5 min and the weighted (1/x(2)) calibration curves were linear over a range of 1.56-200 ng/ml. The limit of detection (LOD) and lower limit of quantification (LLOQ) in rat plasma, rabbit plasma and monkey plasma were 0.78 and 1.56 ng/ml, respectively, for all three analytes. The intra- and inter-batch accuracy and precision in terms of % bias and % relative standard deviation were found to be well within the acceptable limits (< 15%). The average absolute recoveries of 99-357, 99-408 and 99-411 from spiked plasma samples were > 90%, > 70% and > 60%, respectively. The assay method described here could be applied to study the pharmacokinetics of 99-357, 99-408 and 99-411 using sample-pooling technique.  相似文献   

16.
Direct plasma injection technology coupled with a LC-MS/MS assay provides fast and straightforward method development and greatly reduces the time for the tedious sample preparation procedures. In this work, a simple and sensitive bioanalytical method based on direct plasma injection using a single column high-performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) was developed for direct cocktail analysis of double-pooled mouse plasma samples for the quantitative determination of small molecules. The overall goal was to improve the throughput of the rapid pharmacokinetic (PK) screening process for early drug discovery candidates. Each pooled plasma sample was diluted with working solution containing internal standard and then directly injected into a polymer-coated mixed-function column for sample clean-up, enrichment and chromatographic separation. The apparent on-column recovery of six drug candidates in mouse plasma samples was greater than 90%. The single HPLC column was linked to either an atmospheric pressure chemical ionization (APCI) or electrospray ionization (ESI) source as a part of MS/MS system. The total run cycle time using single column direct injection methods can be achieved within 4 min per sample. The analytical results obtained by the described direct injection methods were comparable with those obtained by semi-automated protein precipitation methods within +/- 15%. The advantages and challenges of using direct single column LC-MS/MS methods with two ionization sources in combination of sample pooling technique are discussed.  相似文献   

17.
Two semi-automated, relatively high throughput methods using ultra performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) were developed for the simultaneous determination of ethinyl estradiol (EE) in combination with either 19-norethindrone (NE) or levonorgestrel (LN) in human plasma. Using 300 microL plasma, the methods were validated over the concentration ranges of 0.01-2 ng/mL and 0.1-20 ng/mL for EE and NE (or LN), respectively. The existing methods for the determination of the oral contraceptives in human plasma require large volumes of plasma (> or =500 microL), and sample extraction is labor-intensive. The LC run time is at least 6 min, enabling analysis of only about 100 samples a day. In the present work the throughput was greatly improved by employing a semi-automated sample preparation process involving liquid-liquid extraction and derivatization with dansyl chloride followed by UPLC separation on a small particle size column achieving a run time of 2.7 min. The validation and actual sample analysis results show that both methods are rugged, precise, accurate, and well suitable to support pharmacokinetic studies where approximately 300 samples can be extracted and analyzed in a day.  相似文献   

18.
A sensitive and selective liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the identification and quantification of helicid in rat plasma. The method was based on simple liquid-liquid extraction (LLE). A Kromasil C18 column (150mmx2.00mm, 3.5microm) was used as the analytical column, while a mixture of acetonitrile and 500microM ammonium chloride was used as the mobile phase. MS detection was performed using a single quadrupole mass spectrometer in a negative selected ion monitoring (SIM) mode. The deprotonated molecules [M+Cl](-) at m/z 319.00 and 363.05 were used to quantify helicid and bergeninum (internal standard, I.S.), respectively. The lower limit of quantification of helicid was 1ng/ml. The method was linear in the concentration range of 1-1000ng/ml. The intra-day and inter-day precisions (R.S.D.%) were within 10.0% for the analyte. Helicid proved to be stable during all sample storage, preparation and analytical periods. The method was successfully applied to a pharmacokinetic study in rats after intragastric administration of helicid with a dose of 50mg/kg. Only 50microl of rat plasma at each sampling time was needed for analysis. The proposed method enables unambiguous identification and quantification for the preliminary pharmacokinetic studies of helicid.  相似文献   

19.
A HPLC method has been developed for the analogue of Ecstasy MDE and its major metabolites N-ethyl-4-hydroxy-3-methoxyamphetamine (HME) and 3,4-methylenedioxyamphetamine (MDA) in human plasma. In the course of our investigations we found that the methylenedioxyamphetamines and HME exhibit fluorescence at 322 nm. Therefore the detection could be carried out with a fluorescence (FL) detector. Solid-phase extraction was used for sample preparation and yielded high recovery rates greater than 95%. The limit of quantitation for MDE and its metabolites in the extracts was between 1.5 and 8.9 ng/ml and the method standard deviations were less than 5%. This sensitive, rapid and reliable analytical method has been used successfully in the quantitation of the substances in plasma samples obtained from 14 volunteers in two clinical studies after p.o. administration of 100 to 140 mg MDE*HCl. The maximum plasma concentrations were 235–465 ng/ml (MDE), 67–673 ng/ml (HME) and 7–33 ng/ml (MDA), respectively. Pharmacokinetic parameters have been investigated using the plasma concentration curves.  相似文献   

20.
A fully automated column-switching high-performance liquid chromatographic (HPLC) method was developed for the quantification of finasteride [N-(1,1-dimethylethyl)-3-oxo-4-aza-5α-androst-1-ene-17β-carboxamide] in human plasma. Plasma samples were diluted with an equal volume of ethylene glycol-water (40:60, v/v), then the diluted sample (150 μl) was injected into the HPLC system without clean-up. The analyte was retained on a pretreatment column, whereas plasma proteins and other endogenous components were washed out to waste. The analyte was transferred to the analytical column in the heart-cut mode and then detected at 210 nm. A quantification limit of 1 ng/ml was attained. There was a linear relationship between peak height and drug concentration in plasma in the range 1–50 ng/ml. This method was validated and applied to the assay of plasma samples to characterize pharmacokinetic parameters in clinical studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏