共查询到20条相似文献,搜索用时 15 毫秒
1.
Zhang X Duan J Li K Zhou L Zhai S 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,850(1-2):348-355
A liquid chromatography-mass spectrometry method (LC-MS/MS) for the quantitative determination of rifaximin in human plasma was developed and validated. In the developed procedure, metoprolol was added to human plasma as an internal standard (IS) and acetonitrile was used to precipitate the plasma proteins before LC-MS/MS analysis. Chromatographic separation was obtained on a RESTEK Pinnacle C18 column (50 mm x 2.1mm, 5 microm) with a mobile phase consisted of ammonium acetate solution (15 mM, pH 4.32) as buffer A and methanol as mobile phase B. Quantification was performed in positive mode using multiple reaction monitoring (MRM) of the transitions m/z 786.1-->754.1 for rifaximin and m/z 268.3-->116.1 for the IS. The assay has been validated over the concentration range of 0.5-10 ng/ml (r=0.9992) based on the analysis of 0.2 ml of plasma. The assay accuracy was between 98.2% and 109%. The within-day and between-day precision was better than 3.9% and 8.9% at three concentration levels. The freeze-thaw stability was also investigated and it was found that both rifaximin and the IS were quite stable. This method provides a rapid, sensitive, specific and robust tool for the quantitative determination of rifaximin in human plasma, which is especially useful for the pharmacokinetic study of rifaximin. 相似文献
2.
Zhang J Liang J Tian Y Zhang Z Chen Y 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,858(1-2):129-134
A rapid, sensitive and selective LC-MS/MS method was developed and validated for the quantification of aniracetam in human plasma using estazolam as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using a mobile phase of methanol-water (60:40, v/v) on a reverse phase C18 column and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode using the respective [M+H]+ ions, m/z 220-->135 for aniracetam and m/z 295-->205 for the IS. The assay exhibited a linear dynamic range of 0.2-100 ng/mL for aniracetam in human plasma. The lower limit of quantification (LLOQ) was 0.2 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated LC-MS/MS method has been successfully applied to study the pharmacokinetics of aniracetam in healthy male Chinese volunteers. 相似文献
3.
Ishii A Tanaka M Kurihara R Watanabe-Suzuki K Kumazawa T Seno H Suzuki O Katsumata Y 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,792(1):117-121
We have presented a simple and sensitive method for determining pethidine, a narcotic analgesic drug in body fluids by gas chromatography-tandem mass spectrometry (GC-MS/MS). Pethidine and 4'-piperidinoacetophenone (internal standard) were extracted from body fluids with Bond Elut C(18) columns; the recoveries were above 85% for both compounds. The calibration curves for blood and urine showed good linearities in the range of 1.25-40 ng/ml. Its detection limits (signal-to-noise ratio=3) were estimated to be approximately 0.5 ng/ml of whole blood and urine. 相似文献
4.
Do B Goulay-Dufaÿ S Le Hoang MD Adoui N Graffard H Guyon F Pradeau D 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,845(1):104-108
A simple detection system with a high-performance liquid chromatography (HPLC) with positive ionisation-tandem mass spectrometry (ESI-MS/MS) for determining diphemanil methylsulphate (DMS) levels in human plasma using 4-diphemanylmethylene,1-methylpiperidine as an internal standard (I.S.), is proposed. The acquisition was performed with the multiple reactional monitoring (MRM) mode, by monitoring the transitions: m/z 278>262 for DMS and m/z 263>247 for the I.S. The method involved a simple single-step deproteinisation with acetonitrile. The analyte was chromatographed on a Zorbax C18 reversed-phase chromatographic column by isocratic elution with 10(-3)M ammonium acetate and 10(-3)M hexafluorobutyric acid, adjusted to pH 7.0 with ammoniac/acetonitrile (40/60, v/v). The results were linear over the studied range (0.5-50.0 ng mL(-1)) and the total analysis time for each run was 10 min. The mean extraction apparent recoveries expressed at the 95% intervals of confidence were 94-104% for DMS and 92-106% for the I.S. The intra- and inter-assay precisions were 4.6-8.4% and 2.9-10.6%, respectively. The limit of quantification was 0.15 ng mL(-1). The devised assay was successfully applied to the residual concentrations monitoring in infant. 相似文献
5.
Vieira-Brock PL Miller EI Nielsen SM Fleckenstein AE Wilkins DG 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(30):3465-3474
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of nicotine (NIC), cotinine (COT), nornicotine (NNIC), norcotinine (NCOT), nicotine-N-β-D-glucuronide (NIC GLUC), cotinine-N-β-D-glucuronide (COT GLUC), nicotine-1'-oxide (NNO), cotinine-N-oxide (CNO), trans-3'-hydroxycotinine (3-HC), anabasine (AB) and anatabine (AT) was modified and validated for quantification of these selected analytes in rat brain tissue. This analytical method provides support for preclinical NIC pharmacokinetic and toxicological studies after controlled dosing protocols. After brain homogenization and solid-phase extraction, target analytes and corresponding deuterated internal standards were chromatographically separated on a Discovery(?) HS F5 HPLC column with gradient elution and analyzed by LC-MS/MS in positive electrospray ionization (ESI) mode with multiple reaction monitoring (MRM) data acquisition. Method linearity was assessed and calibration curves were determined over the following ranges: 0.1-7.5 ng/mg for NIC, COT GLUC and AB; and 0.025-7.5 ng/mg for COT, NNIC, NCOT, NIC GLUC, NNO, CNO, 3-HC and AT (R(2)≥0.99 for all analytes). Extraction recoveries ranged from 64% to 115%, LC-MS/MS matrix effects were ≤21%, and overall process efficiency ranged from 57% to 93% at low and high quality control concentrations. Intra- and inter-assay imprecisions and accuracy for all analytes were ≤12.9% and ≥86%, respectively. The method was successfully applied to quantification of NIC and metabolites in the brain of post-natal day 90 rats that were sacrificed 2-h after a single 0.8 mg/kg s.c. administration of (-)NIC. In these tissues, striatal concentrations were 204.8±49.4, 138.2±14.2 and 36.1±6.1 pg/mg of NIC, COT and NNIC, respectively. Concentrations of NIC, COT and NNIC in the remaining whole brain (RWhB) were 183.3±68.0, 130.0±14.1 and 46.7±10.3 pg/mg, respectively. Quantification of these same analytes in plasma was also performed by a previously validated method. NIC, COT, NNIC, NCOT, NNO and CNO were detected in plasma with concentrations comparable to those reported in previous studies. However, and in contrast to brain tissues, COT concentrations in plasma were significantly higher than were those of NIC (194.6±18.6 ng/mL versus 52.7±12.9 ng/mL). Taken together, these results demonstrate that a sensitive and selective method has been developed for the determination of NIC biomarkers in rat brain. 相似文献
6.
Sensitive method for the determination of ibutilide in human plasma by liquid chromatography-tandem mass spectrometry 总被引:1,自引:0,他引:1
Tian L Li Y Huang Y Kuang F Li F Hua L 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,816(1-2):81-85
A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed and validated for determination of ibutilide in human plasma. The analyte and internal standard sotalol were extracted from plasma samples by liquid-liquid extraction, and separated on a C(18) column, using acetonitrile-water-10% butylamine-10% acetic acid (80:20:0.07:0.06, v/v/v/v) as the mobile phase. Detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via TurboIonSpray ionization (ESI). Linear calibration curves were obtained in the concentration range of 20-10,000 pg/ml, with a lower limit of quantitation of 10 pg/ml. The intra- and inter-day precision values were below 8% and accuracy was within +/-3% at all three QC levels. The method was utilized to support clinical pharmacokinetic studies of ibutilide in healthy volunteers following intravenous administration. 相似文献
7.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1995,665(1):97-105
Gas chromatography-tandem mass spectrometry (GC-MS-MS) with selected-reaction monitoring was applied to the analysis of urinary metabolites of sulphur mustard, derived from the β-lyase pathway and from hydrolysis. In the case of β-lyase metabolites, a limit of detection of 0.1 ng/ml was obtained, compared to 2–5 ng/ml using single stage GC-MS with selected-ion monitoring. GC-MS-MS methodology was less useful when applied to the analysis of thiodiglycol bis(pentafluorobenzoate) using negative-ion chemical ionisation although selected-reaction chromatograms were cleaner than selected-ion chromatograms. The advantage of using GC-MS-MS was demonstrated by the detection of low levels of β-lyase metabolites in the urine of casualties who had been exposed to sulphur mustard. 相似文献
8.
Salvador A Dubreuil D Denouel J Millerioux L 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,820(2):237-242
A sensitive LC-MS-MS assay for the quantitative determination of bromocriptine has been developed and validated and is described in this work. The assay involved the extraction of the analyte from 1 ml of human plasma using a solid phase extraction on Oasis MCX cartridges. Chromatography was performed on a Symmetry C18 (2.1 mm x 100 mm, 3.5 microm) column using a mobile phase consisting of 25:75:01 acetonitrile-water-formic acid with a flow rate of 250 microl/min. The linearity was within the concentration range of 2-500 pg/ml. The lower limit of quantification was 2 pg/ml. This method has been demonstrated to be an improvement over existing methods due to its greater sensitivity and specificity. 相似文献
9.
Sensitive liquid chromatography-tandem mass spectrometry method for the determination of clarithromycin in human plasma 总被引:2,自引:0,他引:2
van Rooyen GF Smit MJ De Jager AD Hundt HK Swart KJ Hundt AF 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2002,768(2):223-229
A sensitive method for the determination of clarithromycin in plasma is described, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Samples were prepared using liquid-liquid extraction and separated on a Supelco Discovery C18 column with a mobile phase consisting of acetonitrile, methanol and acetic acid. Detection was performed by a PE SCIEX API 2000 mass spectrometer in the multiple reaction monitoring (MRM) mode (LC-MS-MS) using TurbolonSpray ionization and monitoring the transition of the protonated molecular ion for clarithromycin at m/z 748.5 (M+1) to the predominant product ion of m/z 158.2. The mean recovery of clarithromycin was 87.3%, with a lower limit of quantification of 2.95 ng/ml when using 0.3-ml plasma. This high-throughput method was used to quantify 230 samples per day, and is sufficiently sensitive to be employed in pharmacokinetic studies. 相似文献
10.
Bravo R Caltabiano LM Fernandez C Smith KD Gallegos M Whitehead RD Weerasekera G Restrepo P Bishop AM Perez JJ Needham LL Barr DB 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,820(2):229-236
We have developed a method to measure 12 urinary phenolic metabolites of pesticides or related chemicals. The target chemicals for our method are 2-isopropoxyphenol; 2,4-dichlorophenol; 2,5-dichlorophenol; carbofuranphenol; 2,4,5-trichlorophenol; 2,4,6-trichlorophenol; 3,5,6-trichloro-2-pyridinol; para-nitrophenol, ortho-phenylphenol, pentachlorophenol, 1-naphthol and 2-naphthol. The sample preparation involves enzyme hydrolysis, isolation of the target chemicals using solid phase extraction cartridges, a phase-transfer catalyzed derivatization, cleanup using sorbent-immobilized liquid/liquid extraction cartridges, and concentration of the sample. Derivatized samples are analyzed by capillary gas chromatography-tandem mass spectroscopy using isotope dilution calibration for quantification. The limits of detection are in the mid ng/L range and the average coefficient of variation was below 15% for most of the analytes. Using our method, we measured concentrations of the target chemicals in urine samples from the general population. 相似文献
11.
James G. Bollinger Hiromi Ii Martin Sadilek Michael H. Gelb 《Journal of lipid research》2010,51(2):440-447
LC/ESI-MS/MS has been previously demonstrated to be a powerful method to detect and quantify molecular species of glycerophospholipids including lysophospholipids. In this study, we provide an improved pre-mass spectrometry lipid extraction procedure that avoids the acid-catalyzed decomposition of plasmenyl phospholipids that is problematic with previously reported methods. We show that the use of lysophospholipid internal standards with perdeuterated fatty acyl chains avoids isobar problems associated with the use of internal standards containing odd carbon number fatty acyl chains. We also show that LC prior to MS is required to avoid numerous problems associated with isobars and with MS in-source decomposition of lysophosphatidylserine. The reported method of using normal phase chromatography/ESI-MS is used to quantify lysophospholipids in serum and to quantify lysophospholipids produced in mammalian cells by human group X secreted phospholipase A2. The latter shows that group X phospholipase A2 added exogenously to cells generates a different set of lysophospholipids compared with enzyme produced endogenously in cells, which supports earlier studies showing that this phospholipase A2 can act on cell membranes prior to externalization from cells. 相似文献
12.
Because of the recognized inaccuracy and unreliability of currently available methods for the quantification of histamine in biological fluids, a method for quantification of urinary histamine by stable isotope dilution assay with negative ion chemical ionization mass spectrometry has been developed. Following the addition of [2H4]histamine to 1 ml of urine, histamine is extracted into butanol, back-extracted into HCl, derivatized to the pentafluorobenzyl derivative (CH2C6F5)3-histamine, extracted into methylene chloride, and then quantified with negative ion chemical ionization mass spectrometry by selected ion monitoring of the ratio of ions . Twenty samples can be assayed in 2 days. Precision of the assay is ±2.7% and the accuracy is 97.6%. Lower limits of sensitivity are approximately 100–500 fg injected on-column. This assay provides a very sensitive, accurate, and efficient method for the quantification of histamine in human urine. 相似文献
13.
Rodin I Braun A Stavrianidi A Shpigun O Rybalchenko I 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(32):3788-3796
A sensitive and simple method for the quantification and for the detection of 2-chlorovinylarsonous (CVAA) and 2-chlorovinylarsonic (CVAOA) acids was developed. CVAA and CVOA are important biological markers in human and rat urine specific to lewisite (chlorovinylarsonous chloride compounds) exposure. The developed assay was based on the use of solid-phase extraction (SPE) followed by liquid-chromatography coupled to electrospray ionization (negative ion-mode) low-energy collision dissociation-tandem mass spectrometry (ESI-CID-MS/MS). The method demonstrated linearity over at least three orders of magnitude and had a detection limit (LOD) of 0.5 ng/ml for CVAA and 3 ng/ml for CVAOA. The relative standard deviations for the quality control samples ranged from 6 to 11%. Application of this procedure was demonstrated in the lewisite animals exposure model. Rats were exposed intravenously by no lethal doses of lewisite and markers levels in urine samples were analyzed for 21 days post-exposure. 相似文献
14.
Reyns T Cherlet M De Baere S De Backer P Croubels S 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,861(1):108-116
A fast method for the quantitative determination of amoxicillin (AMO), amoxicilloic acid (AMA) and amoxicillin diketopiperazine-2',5'-dione (DIKETO) in pig edible tissues (kidney, liver, fat and muscle) with liquid chromatography-tandem mass spectrometry (LC-ESI-MS/MS) is presented. The method uses a simple liquid-liquid extraction of the tissue matrix with a 10 mM potassium dihydrogen phosphate buffer (pH 4.5) as extraction solvent. After deproteinisation by ultrafiltration, the tissue extract was directly injected onto the LC column. Chromatographic separation of the components was performed on a PLRP-S polymeric column using 0.1% of formic acid in water and acetonitrile. The mass spectrometer was operated in the positive electrospray MS/MS mode. The method was fully validated according to EU requirements (linearity, precision, trueness, quantification limit, detection limit and specificity). The stability of the components was evaluated over the pH range from 1.2 to 8.0. Biological samples of pigs medicated with AMO and AMO/clavulanic acid were analyzed using the developed method. 相似文献
15.
Sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of meloxicam in human plasma 总被引:2,自引:0,他引:2
Wiesner JL de Jager AD Sutherland FC Hundt HK Swart KJ Hundt AF Els J 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,785(1):115-121
Meloxicam was quantified in human plasma after a single 15 mg oral dose of the drug was given to 26 healthy volunteers. An Applied Biosystems Sciex API 2000 triple quadrupole mass spectrometer in multiple reaction monitoring (MRM) mode, using TurboIonSpray (TIS) in the positive ion mode, was used. Protein precipitation with acetonitrile was followed by C(18) reverse phase liquid chromatography and tandem mass spectrometry. The mean recovery for meloxicam was 92% with a lower limit of quantification of 8.96 ng/ml. Piroxicam was used as the internal standard. This assay method makes use of the increased sensitivity and selectivity of tandem mass spectrometry (MS-MS) detection to allow for a more rapid (extraction and chromatography) and selective method for the determination of meloxicam in human plasma than has previously been described. 相似文献
16.
Sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of stavudine in human plasma 总被引:5,自引:0,他引:5
Wiesner JL Sutherland FC Smit MJ van Essen GH Hundt HK Swart KJ Hundt AF 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2002,773(2):129-134
A sensitive method for the determination of stavudine in plasma was developed, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted from plasma with Waters, Sep-Pak Vac, 100 mg, tC(18) solid-phase extraction (SPE) columns. Chromatography was performed on a Supelco Discovery C(18), 5 microm, 150 x 2 mm column with a mobile phase consisting of ammonium acetate (0.01 M)-acetonitrile-methanol (800:100:100, v/v/v) at a flow-rate of 0.3 ml/min. Detection was achieved by an Applied Biosystems API 2000 mass spectrometer (LC-MS-MS) set at unit resolution in the multiple reaction monitoring mode (MRM). Atmospheric pressure chemical ionization (APCI) was used for ion production. The mean recovery for stavudine was 94% with a lower limit of quantification set at 4 ng/ml. This assay method makes use of the increased sensitivity and selectivity of mass spectrometric (MS-MS) detection to allow for a more rapid (extraction and chromatography) and selective method for the determination of stavudine in human plasma than has previously been described. 相似文献
17.
Previously, we demonstrated the utility of a gas chromatography–tandem mass spectrometry (GC–MS/MS) method for the quantitative determination of asymmetric dimethylarginine (ADMA) in biological samples. Here we report the extension of this method to symmetric dimethylarginine (SDMA) in human urine. SDMA and ADMA were simultaneously quantitated in urine by using their in situ prepared trideuteromethyl esters as internal standards. The GC–MS/MS method was validated for SDMA and ADMA in spot urine samples of 19 healthy adults. In these samples, the creatinine-corrected excretion rate was 3.23 ± 0.63 μmol/mmol for SDMA and 3.14 ± 0.98 μmol/mmol for ADMA. 相似文献
18.
Cavalcanti Gde A Garrido BC Leal FD Padilha MC de la Torre X de Aquino Neto FR 《Steroids》2011,76(10-11):1010-1015
Exemestane is an aromatase enzyme complex inhibitor. Its metabolism in humans is not fully described and there is only one known metabolite: 17β-hydroxyexemestane. In this work, excretion studies were performed with four volunteers aiming at the detection of new exemestane metabolites in human urine by gas chromatography coupled to mass spectrometry (GC-MS) after enzymatic hydrolysis and liquid-liquid extraction. Urine samples collected from four volunteers were analyzed separately. The targets of the study were mainly the 6-exomethylene oxidized metabolites. Two unreported metabolites were identified in both free and glucuconjugated urine fractions from all four volunteers, both of them were the result of the 6-exomethylene moiety oxidation: 6ξ-hydroxy-6ξ-hydroxymethylandrosta-1,4-diene-3,17-dione (metabolite 1) and 6ξ-hydroxyandrosta-1,4-diene-3,17-dione (metabolite 2). Furthermore, only in glucoconjugated fractions from all volunteers, one metabolite arising from the A-ring reduction was identified as well, 3ξ-hydroxy-5ξ-androst-1-ene-6-methylene-17-one (metabolite 3). The molecular formulae of all these metabolites were ascertained by the determination of exact masses using gas chromatography coupled to high resolution mass spectrometry (GC-HRMS). Moreover, all metabolites were confirmed using an alternative derivatization with methoxyamine and MSTFA/TMS-imidazole. 相似文献
19.
Sahasranaman S Tang Y Biniasz D Hochhaus G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,819(1):175-179
A robust, rapid, selective and sensitive liquid chromatography-negative atmospheric pressure chemical ionization (LC-(APCI(-))-MS-MS) method has been developed for the quantification of mometasone furoate (MF) in human plasma utilizing a solid-phase extraction clean-up step and 13C-fluticasone propionate as internal standard. The intra- and inter-day coefficients of variation were < or = 15% and the lower limit of quantification (LLOQ) was 15 pg/ml. This method is ideally suited for pharmacokinetic investigations of low MF levels following inhalation of MF. 相似文献
20.
Benoit-Biancamano MO Caron P Lévesque E Delage R Couture F Guillemette C 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,858(1-2):159-167
A method to determine total and free mycophenolic acid (MPA) and its metabolites, the phenolic (MPAG) and acyl (AcMPAG) glucuronides, using HPLC and mass spectrometry was developed. Mean recoveries in plasma and urine samples were >85%, and the lower limits of quantification for MPA, MPAG and AcMPAG were 0.05, 0.05 and 0.01 mg/L, respectively. For plasma, the assay was linear over 0.05-50 mg/L for MPA and MPAG, and from 0.01 to 10mg/L for AcMPAG. A validation study demonstrated good inter- and intra-day precision (CV相似文献