首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Coactivation of knee flexors during knee extension assists in joint stability by exerting an opposing torque to the anterior tibial displacement induced by the quadriceps. This opposing torque is believed to be generated by eccentric muscle actions that stiffen the knee, thereby attenuating strain to joint ligaments, particularly the anterior cruciate ligament (ACL). However, as the lengths of knee muscles vary with changes in joint position, the magnitude of flexor/extensor muscle force coupling may likewise vary, possibly affecting the capacity for active knee stabilization. The purpose of this study was to assess the effect of changes in movement speed and joint position on eccentric/concentric muscle action relationships in the knees of uninjured (UNI) and post-ACL-surgery (INJ) subjects (n = 14). All subjects were tested for maximum eccentric and concentric torque of the contralateral knee flexors and extensor muscles at four isokinetic speeds (15 degrees-60 degrees x s(-1)) and four joint position intervals (20 degrees-60 degrees of knee flexion). Eccentric flexor torque was normalized to the percentage of concentric flexor torque generated at each joint position interval for each speed tested (flexor E-C ratio). In order to estimate the capacity of the knee flexors to resist active knee extension, the eccentric-flexor/concentric-extensor ratios were also computed for each joint position interval and speed (flexor/extensor E-C ratio). The results revealed that eccentric torque surpassed concentric torque by 3%-144% across movement speeds and joint position intervals. The magnitude of the flexor E-C ratio and flexor/extensor E-C increased significantly with speed in both groups of subjects (P < 0.05) and tended to rise with muscle length as the knee was extended; peak values were generated at the most extended joint position (20 degrees-30 degrees). Although torque development patterns were symmetrical between the contralateral limbs in both groups, between-group comparisons revealed significantly higher flexor/extensor E-C ratios for the INJ group compared to the UNI group (P < 0.05), particularly at the fastest speed tested (60 degrees x s(-1)). The results indicate that joint position and movement speed influence the eccentric/concentric relationships of knee flexors and extensors. The INJ subjects appeared to accommodate to surgery by developing the eccentric function of their ACL and normal knee flexors, particularly at higher speeds and at more extended knee joint positions. This may assist in the dynamic stabilization of the knee at positions where ACL grafts have been reported to be most vulnerable to strain.  相似文献   

2.
The influence of an eccentric training on torque/angular velocity relationships and coactivation level during maximal voluntary isokinetic elbow flexion was examined. Seventeen subjects divided into two groups (Eccentric Group EG, n = 9 Control Group CG, n = 8) performed on an isokinetic dynamometer, before and after training, maximal isokinetic elbow flexions at eight angular velocities (from - 120 degrees s(-1) under eccentric conditions to 240 degrees s(-1) under concentric conditions), and held maximal and submaximal isometric actions. Under all conditions, the myoelectric activities (EMG) of the biceps and the triceps brachii muscles were recorded and quantified as the RMS value. Eccentric training of the EG consisted of 5x6 eccentric muscle actions at 100 and 120% of one maximal repetition (IRM) for 21 sessions and lasted 7 weeks. In the EG after training, torque was significantly increased at all angular velocities tested (ranging from 11.4% at 30 degrees (s-1) to 45.5% at - 120 degrees s(-1)) (p < 0.05). These changes were accompanied by an increase in the RMS activities of the BB muscle under eccentric conditions (from - 120 to - 30 degrees (s-1)) and at the highest concentric angular velocities (180 and 24 degrees s(-1)) (p < 0.05). The RMS activity of the TB muscle was not affected by the angular velocity in either group for all action modes. The influence of eccentric training on the torque gains under eccentric conditions and for the highest velocities was attributed essentially to neural adaptations.  相似文献   

3.
The purpose of this study was to examine the ability to control knee-extension force during discrete isometric (IC), concentric (CC), and eccentric contractions (EC) in 24 young (mean age +/- SD = 25.3 +/- 2.8 yr) and 24 old (mean age +/- SD = 73.3 +/- 5.5 yr) healthy and active individuals. Subjects were to match a parabola with a time to peak force of 200 ms during IC, CC, and EC at six target levels of force [20, 35, 50, 65, 80, and 90% of the maximum voluntary contraction (MVC)]. ICs were performed at 90 degrees of knee flexion, whereas CCs and ECs ranged from 90 to 80 degrees of knee flexion (0 degrees is full extension) at a slow velocity (25 degrees /s). Results showed that subjects produced similar MVC forces for the three types of contractions. Young subjects produced greater MVC forces than old subjects, and within each age group, men produced greater force than women. The variability (standard deviation) of peak force and impulse in absolute values was greater for young compared with old subjects. When variability was normalized to the force produced [coefficient of variation (CV)], however, old subjects exhibited greater CV than young subjects for peak force and impulse. Both the standard deviation and CV of time to peak force and impulse duration were greater for the old adults. In general, ECs were more variable than ICs and CCs, and old adults exhibited greater CV compared with young adults during rapid, discrete ICs, CCs, and particularly ECs of the quadriceps.  相似文献   

4.
The relationship between ciliary neurotrophic factor (CNTF) genotype and muscle strength was examined in 494 healthy men and women across the entire adult age span (20-90 yr). Concentric (Con) and eccentric (Ecc) peak torque were assessed using a Kin-Com isokinetic dynamometer for the knee extensors (KE) and knee flexors (KF) at slow (0.52 rad/s) and faster (3.14 rad/s) velocities. The results were covaried for age, gender, and body mass or fat-free mass (FFM). Individuals heterozygous for the CNTF null (A allele) mutation (G/A) exhibited significantly higher Con peak torque of the KE and KF at 3.14 rad/s than G/G homozygotes when age, gender, and body mass were covaried (P < 0.05). When the dominant leg FFM (estimated muscle mass) was used in place of body mass as a covariate, Con peak torque of the KE at 3.14 rad/s was also significantly greater in the G/A individuals (P < 0.05). In addition, muscle quality of the KE (peak torque at 3.14 rad x s(-1) x leg muscle mass(-1)) was significantly greater in the G/A heterozygotes (P < 0.05). Similar results were seen in a subanalysis of subjects 60 yr and older, as well as in Caucasian subjects. In contrast, A/A homozygotes demonstrated significantly lower Ecc peak torque at 0.52 rad/s for both KE and KF compared with G/G and G/A groups (P < 0.05). No significant relationships were observed at 0.52 rad/s between genotype and Con peak torque. These data indicate that individuals exhibiting the G/A genotype possess significantly greater muscular strength and muscle quality at relatively fast contraction speeds than do G/G individuals. Because of high positive correlations between fast-velocity peak torque and muscular power, these findings suggest that further investigations should address the relationship between CNTF genotype and muscular power.  相似文献   

5.
Forty men were tested with a computerized dynamometer for concentric and eccentric torques during arm flexion and extension at 0.52, 1.57, and 2.09 rad.s-1. Based on the summed concentric and eccentric torque scores, subjects were placed into a high strength (HS) or low strength (LS) group. The eccentric and concentric segments of the torque-velocity curves (TVCs) were generated using peak torque and constant-angle torque (CAT) at 1.57 and 2.36 rad. Angle of peak torque was also recorded. Compared to LS, HS had significantly greater estimated lean body mass (+10.2 kg) and approximately 25% greater average torque output. Reliability of the peak torque scores on 2 days in 20 subjects was r greater than or equal to 0.85. The difference between observed torques and the mathematically computed criterion torque scores averaged 1% for three validation loads that ranged from 11.4 to 90.4 kg. Statistical analysis revealed that torque output in LS plateaued at low concentric velocities and was also flattened with increasing eccentric velocities. Conversely, torque output for HS increased with decreasing concentric velocities and increased with increasing eccentric velocities. The method of plotting the TVCs for peak or CAT did not influence the pattern of TVC. Eccentric flexion peak torque occurred at a significantly shorter muscle length (1.88 rad) than concentric torque (2.12 rad). This difference was also present for extension; it was 1.88 rad for eccentric and 2.03 rad for concentric torque.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

6.
The purpose of this investigation was to determine the influence of contraction velocity on the eccentric (ECC) and concentric (CON) torque production of the biceps brachii. After performing warm-up procedures, each male subject (n = 11) completed 3 sets of 5 maximal bilateral CON and ECC isokinetic contractions of the biceps at speeds of 90, 180, and 300 degrees x s(-1) on a Biodex System 3 dynamometer. The men received a 3-minute rest between sets and the order of exercises was randomized. Peak torque (Nm) values were obtained for CON and ECC contractions at each speed. Peak torque scores (ECC vs. CON) were compared using a t-test at each speed. A repeated measures analysis of variance was used to determine differences between speeds. ECC peak torque scores were greater than CON peak torque scores at each given speed: 90 degrees x s(-1), p = 0.0001; 180 degrees x s(-1), p = 0.0001; and 300 degrees x s(-1), p = 0.0001. No differences were found between the ECC peak torque scores (p = 0.62) at any of the speeds. Differences were found among the CON scores (p = 0.004). Post hoc analysis revealed differences between 90 degrees x s(-1) (114.61 +/- 23) and 300 degrees x s(-1) (94.17 +/- 18). These data suggest that ECC contractions of the biceps brachii were somewhat resistant to a force decrement as the result of an increase in velocity, whereas CON muscular actions of the biceps brachii were unable to maintain force as velocity increased.  相似文献   

7.
The purpose of this study was to compare pure eccentric and concentric isokinetic training with respect to their possible specificity in the adaptation of strength and morphology of the knee extensor muscles. Ten moderately trained male physical education students were divided into groups undertaking eccentric (ETG) and concentric (CTG) training. They performed 10 weeks of maximal isokinetic (90 degrees x s(-1)) training of the left leg, 4x10 repetitions - three times a week, followed by a second 10-week period of similar training of the right-leg. Mean eccentric and concentric peak torques increased by 18% and 2% for ETG and by 10% and 14% for CTG, respectively. The highest increase in peak torque occurred in the eccentric 90 degrees x s(-1) test for ETG (35%) whereas in CTG strength gains ranged 8%-15% at velocities equal or lower than the training velocity. Significant increases in strength were observed in the untrained contra-lateral leg only at the velocity and mode used in ipsilateral training. Cross-sectional area of the quadriceps muscle increased 3%-4% with training in both groups, reaching statistical significance only in ETG. No major changes in muscle fibre composition or areas were detected in biopsies from the vastus lateralis muscle for either leg or training group. In conclusion, effects of eccentric training on muscle strength appeared to be more mode and speed specific than corresponding concentric training. Only minor adaptations in gross muscle morphology indicated that other factors, such as changes in neural activation patterns, were causing the specific training-induced gains in muscle strength.  相似文献   

8.
A method was developed to indirectly measure friction between the flexor tendons and pulleys of the middle and ring finger in vivo. An isokinetic movement device to determine maximum force of wrist flexion, interphalangeal joint flexion (rolling in and out) and isolated proximal interphalangeal (PIP) joint flexion was built. Eccentric and concentric maximum force of these three different movements where gliding of the flexor tendon sheath was involved differently (least in wrist flexion) was measured and compared. Fifty-one hands in 26 male subjects were evaluated. The greatest difference between eccentric and concentric maximum force (29.9%) was found in flexion of the PIP joint. Differences in the rolling in and out movement (26.8%) and in wrist flexion (14.5%) were significantly smaller. The force of friction between flexor tendons and pulleys can be determined by the greater difference between eccentric and concentric maximum force provided by the same muscles in overcoming an external force during flexion of the interphalangeal joints and suggests the presence of a non-muscular force, such as friction. It constitutes of 9% of the eccentric flexion force in the PIP joint and therefore questions the low friction hypothesis at high loads.  相似文献   

9.
Motor unit activation patterns were studied during four different force levels of concentric and eccentric actions. Eight male subjects performed concentric and eccentric forearm flexions with the movement range from 100 degrees to 60 degrees in concentric and from 100 degrees to 140 degrees elbow angle in eccentric actions. The movements were started either from zero preactivation or with isometric preactivation of the force levels of 20, 40, 60 and 80% MVC. The subjects were then instructed to maintain the corresponding relative force levels during the dynamic actions. Intramuscular and surface EMG was recorded from biceps brachii muscle. Altogether 28 motoneuron pools were analyzed using the intramuscular spike-amplitude frequency (ISAF) analysis technique of Moritani et al. The mean spike amplitude was lower and the mean spike frequency higher in the isometric preactivation phase than in the consequent concentric and eccentric actions. When the movements started with isometric preactivation the mean spike amplitude increased significantly (P<0.001) up to 80% in isometric and concentric actions but in eccentric actions the increase continued only up to 60% (P<0.01). The mean spike frequency in isometric preactivation and in concentric action with preactivation was lower only at the 20% force level (P<0.01) as compared to the other force levels while in eccentric action with preactivation the increase between the force levels was significant (P<0.01) up to 60%. When the movement was started without preactivation the mean spike amplitude at 20% and at 40% force level was higher (P<0.01) in eccentric action than in concentric actions. It was concluded that the recruitment threshold may be lower in dynamic as compared to isometric actions. The recruitment of fast motor units may continue to higher force levels in isometric and in concentric as in eccentric actions which, on the other hand, seems to achieve the higher forces by increasing the firing rate of the active units. At the lower force levels mean spike amplitude was higher in eccentric than in concentric actions which might indicate selective activation of fast motor units. This was, however, the case only when the movements were started without isometric preactivation.  相似文献   

10.
The purpose of this study was to determine if differences exist between the control strategies of two antagonist thigh muscles during knee flexion and extension muscular coactivation. Surface myoelectric signal (MES) of the quadriceps (rectus femoris) and the hamstrings (semitendinosus) were obtained from both muscles while performing step-wise increasing contractions during flexion and extension with the knee at 1.57 rad of flexion (90 degrees). The median frequency of the power density spectrum, which is related to the average muscle fiber action potential conduction velocity and therefore to motor unit recruitment, was calculated from each MES. The results suggest that, in all the subjects tested, when the muscle acts as antagonist most motor units are recruited up to 50% of the maximal voluntary force, whereas when the muscle acts as antagonist motor units are recruited up to 40% of the maximal voluntary force. The force range past 40–50% of the maximal force is also characterized by differences between the agonist/antagonist.  相似文献   

11.
The purpose of this study was to show that velocity-specific training may be implicated in modifications in the level of coactivation of agonist and antagonist muscles. Healthy males (n = 20) were randomly placed in to two groups: one group trained using concentric contractions (n = 12), the other was an untrained control group (n = 8). The training group underwent unilateral resistance training at a level of 35 (5)% of a one-repetition maximal contraction of the elbow flexors, executed at maximal angular velocity. Training sessions consisted of six sets of eight consecutive elbow flexions, three times per weak for a total of seven weeks. The velocity of the ballistic movements executed during training were measured using an optoelectronic measuring device (Elite), both at the beginning and at the end of the training period. Subjects were tested pre- and post-training during isokinetic maximal elbow flexions with constant angular torque (CAT) at 90 degrees (0 degrees = full extension), and at different velocities (60, 120, 180, 240 and 300 degrees x s(-1)) for concentric actions, and -60 and -30 degrees x s(-1) for eccentric and isometric contractions at 90 degrees. In order to verify the levels of activation of the agonist biceps brachii (BB) muscles and antagonist triceps brachii (TB) muscles during maximal voluntary activation, their myoelectrical activities were recorded and quantified as root mean square (RMS) amplitudes, between angles of 75 and 105 degrees . The results show that mean angular velocities between elbow angles of 75 and 105 degrees were similar before [302 (32) degrees x s(-1)] and after [312 (27) degrees x s(-1)] the training period. CAT significantly increased measures at angular velocities of 240 and 300 degrees x s(-1) by 18.7% and 23.5%, respectively. The RMS activity of BB agonist muscles was not significantly modified by training. Post-training normalized RMS amplitudes of TB antagonist muscles were inferior to those observed at pre-training, but values were only significantly different at 300 x s(-1). In conclusion, in this study we attempted to show that an increase of CAT to 240 and 300 degrees x s(-1), though velocity-specific training, may be due, in part, to a lowering of the level of coactivation.  相似文献   

12.
The present study aimed to clarify the effects of knee joint angle on the behavior of the medial gastrocnemius muscle (MG) fascicles during eccentric plantar flexions. Eight male subjects performed maximal eccentric plantar flexions at two knee positions [fully extended (K0) and 90° flexed (K90)]. The eccentric actions were preceded by static plantar flexion at a 30° plantar flexed position and then the ankle joint was forcibly dorsiflexed to 15° of dorsiflexion with an isokinetic dynamometer at 30°/s and 150°/s. Tendon force was calculated by dividing the plantar flexion torque by the estimated moment arm of the Achilles tendon. The MG fascicle length was determined with ultrasonography. The tendon forces during eccentric plantar flexions were influenced by the knee joint angle, but not by the angular velocity. The MG fascicle lengths were elongated as the ankle was dorsiflexed in K0, but in K90 they were almost constant despite the identical range of ankle joint motion. These results suggested that MG fascicle behavior during eccentric actions was markedly affected by the knee joint angle. The difference in the fascicle behavior between K0 and K90 could be attributed to the non-linear force–length relations and/or to the slackness of tendinous tissues.  相似文献   

13.
This study aimed to examine the relationships between muscle power output using the stretch-shortening cycle (SSC) and eccentric maximum strength under elbow flexion. Eighteen young adult males pulled up a constant light load (2 kg) by ballistic elbow flexion under the following two preliminary conditions: 1) the static relaxed muscle state (SR condition), and 2) using the SSC with countermovement (SSC condition).Muscle power was determined from the product of the pulling velocity and the load mass by a power measurement instrument that adopted the weight-loading method. We assumed the pulling velocity to be the subject's muscle power parameters as a matter of convenience, because we used a constant load. The following two parameters were selected in reference to a previous study: 1) peak velocity (m x s(-1)) (peak power) and 2) 0.1-second velocity during concentric contraction (m x s(-1)) (initial power). Eccentric maximum strength by elbow flexion was measured by a handheld dynamometer.Initial power produced in the SSC condition was significantly larger than that in the SR condition. Eccentric maximum strength showed a significant and high correlation (r = 0.70) with peak power in the SSC condition but not in the SR condition. Eccentric maximum strength showed insignificant correlations with initial power in both conditions. In conclusion, it was suggested that eccentric maximum strength is associated with peak power in the SSC condition, but the contribution of the eccentric maximum strength to the SSC potentiation (initial power) may be low.  相似文献   

14.
Muscle strength (or muscular moment) generated during dynamic contractions varies with joint angle. This raises the question about the choice of a representative angle in the evaluation of strength capacity. To assess this angle dependency in strength measurements, dynamic moment-angle curves for plantar flexor muscles were obtained in 43 healthy subjects (28 men and 15 women) with a controlled acceleration dynamometer at 0.52 rad s-1 (30 degrees s-1) and using maximal static preloading before the beginning of movement to attenuate the force development phase. Differences between gender and correlations between strength and anthropometric measures were calculated at each 0.087 rad (5 degrees). The plantar flexion moment was larger in men, in general, but this difference was largest when the ankle was most dorsiflexed. The correlations between moment and anthropometric measures were also higher in the first half of the plantar flexion movement. These results stress the importance of reporting joint angles at which moment of force measures were made. Furthermore, they show that the maximal strength capacity of the plantar flexors is best represented by the moment measured in dorsiflexion angles when the muscles are lengthened.  相似文献   

15.
The purpose of this study was to determine the stability and accuracy of active knee joint velocity replication methods in healthy subjects. We used a repeated measures design with 14 healthy volunteers. Measures of velocity replication were performed in two ranges of knee joint flexion (0 degrees -30 degrees and 60 degrees -90 degrees ), across four testing velocities (5, 10, 15, and 30 degrees /s) in two movement directions (flexion and extension). Statistical analysis included intraclass correlation coefficients (ICCs; 2, k) and associated standard error of the measures calculated between day 1 and 2. We performed z-tests between all possible combinations of ICC pairs using Fisher's Z transformations to determine if any significant differences existed between observed ICCs. We also calculated correlation ratios (eta2) to explain the source of variability in the calculated ICCs. To assess measurement accuracy, we calculated constant error and absolute error between criterion and replication velocities. Results on ICCs and standard error of the measurements (SEMs) ranged from r = -0.44 +/- 7.00 to 0.88 +/- 0.72 degrees /s. Calculated z-tests indicated six paired ICCs were significantly different ( p < 0.1). In all six pairs, the faster test velocity had a lower ICC magnitude. The eta2 calculations demonstrated that inconsistent performance between day 1 and 2 caused the low ICC magnitudes observed with faster testing velocities. Significantly more absolute error occurred at 30 and 15 degrees /s compared with 5 degrees /s. Significantly less constant error was observed for 30 degrees /s compared with 15 degrees /s. A significant direction by range of motion interaction indicated less constant error for flexion movements in the 60 degrees -90 degrees range of motion (ROM) as compared with extension movements in either ROM. Healthy individuals could actively replicate slower criterion velocities in the mid and end ranges of knee joint motion in both movement directions with an acceptable amount of consistency and accuracy. The data support the use of velocity replication in future investigations on proprioceptive function.  相似文献   

16.
The aim of this investigation was to study the relationships among movement velocity, torque output and electromyographic (EMG) activity of the knee extensor muscles under eccentric and concentric loading. Fourteen male subjects performed maximal voluntary eccentric and concentric constant-velocity knee extensions at 45, 90, 180 and 360 degrees.s-1. Myoelectric signals were recorded, using surface electrodes, from the vastus medialis, vastus lateralis and rectus femoris muscles. For comparison, torque and full-wave rectified EMG signals were amplitude-averaged through the central half (30 degrees-70 degrees) of the range of motion. For each test velocity, eccentric torque was greater than concentric torque (range of mean differences: 20%-146%, P less than 0.05). In contrast, EMG activity for all muscles was lower under eccentric loading than velocity-matched concentric loading (7%-31%, P less than 0.05). Neither torque output nor EMG activity for the three muscles changed across eccentric test velocities (P greater than 0.05). While concentric torque increased with decreasing velocity, EMG activity for all muscles decreased with decreasing velocity (P less than 0.05). These data suggest that under certain high-tension loading conditions (especially during eccentric muscle actions), the neural drive to the agonist muscles was reduced, despite maximal voluntary effort. This may protect the musculoskeletal system from an injury that could result if the muscle was to become fully activated under these conditions.  相似文献   

17.
Isokinetic strength measurements of the quadriceps and hamstring that are commonly conducted using a 90 degrees range of motion (RoM) may involve some risk to specific knee patient groups. Testing these muscles at a much shorter RoM may reduce the risk but in order to render this method clinically acceptable the reproducibility of the derived test findings has to be established. Therefore the main objective of this study was to assess the reproducibility of isokinetic peak torque and normalized EMG scores of these muscles based on 90 degrees (0-90 degrees flexion, LR) and three successive short RoMs: 0-30 degrees (SR1), 30-60 degrees (SR2) and 60-90 degrees (SR3). Eight healthy subjects were tested three times with a 2 week between-session interval. All tests were performed on the dominant limb and consisted of maximal concentric and eccentric exertions. The velocities applied were 90 degrees /s for LR and 30 degrees /s for each of the SRs. Findings indicated no between-session improvement in strength. Based on the coefficient of variation the measurement error for all isokinetic strength scores remained stable throughout the testing sessions ranging 0.6-13.9% with the absolute majority of instances less than 10%. The reproducibility of the EMG scores was poorer ranging 1.5-25% and 0.5-19% for the quadriceps and hamstring, respectively. It is concluded that testing of knee muscles at short (30 degrees ) RoMs does not compromise the reproducibility of the strength or EMG scores derived from the commonly used RoM of 90 degrees . However, whereas strength was reproducible to within the accepted clinical standards, the corresponding EMG scores were characterized by a wider error band.  相似文献   

18.
The aim of the present study was to compare electromyographic activity during fitness exercises, walking, and running among 3 different dorsiflexion shoes (+2 degrees , +4 degrees , and +10 degrees ) and standard shoes (-4 degrees ). The 3 different dorsiflexion shoes tested in this study have a curvature placed in the middle of the sole. This design was specially projected to decrease the metatarsus flexion. Electromyographic activity of 9 lower limb muscles was measured on 12 healthy female subjects during 5 fitness exercises (unload squat, side and front step, submaximal ballistic plantar flexion, and lunge exercise), and during running (10 km x h(-1)) and walking (4.5 km x h(-1)) on a treadmill. EMG signal was analyzed with the root mean square (RMS) and integrated EMG. All RMS data measured during these exercises were expressed as percentages of maximum voluntary isometric contraction. The results show that dorsiflexion affects muscle recruitment and reorganizes the motor pattern. The general tendency was that the tibialis anterior activity increased with dorsiflexion. However, an optimal dorsiflexion existed for various exercises. It is concluded that shoes with moderate dorsiflexion can activate lower limb muscles differently compared with both standard shoes and shoes with large dorsiflexion during submaximal exercises and locomotion.  相似文献   

19.
It is a reasonable expectation that voluntarily activated spinal motoneurons will be further excited by increases in spindle afferent activity produced by muscle stretch. Human motor behavior attributed to tonic stretch reflexes and to reflexes recruited by relatively slow joint rotation has been reported from several laboratories. We reinvestigated this issue by rotating the elbow joint over the central portion of its range while subjects focused on keeping their elbow flexion effort constant at one of three different levels and made no attempt to control the position, speed or direction of movement of their forearm. There is evidence that subjects' voluntary motor status is constant under these conditions so that any change in torque would be of involuntary origin. On average, torques rose somewhat and then fell as the elbow was flexed through a range of 80 degrees at 10, 20 and 60 degrees/s and a similar pattern occurred during elbow extension; i.e., both concentric and eccentric torque-angle profiles had roughly similar shapes and neither produced consistent stabilizing cross-range stiffness. The negative stiffness (rising torque) during the early part of a concentric movement and the negative stiffness (falling torque) during the later part of an eccentric movement would not have occurred if a stabilizing stretch reflex had been present. Positive stiffness rarely gave rise to torque changes greater than 20% in either individual or cross-subject averaged data. When angular regions of negative stiffness are combined with regions of low positive stiffness (torque change 10% or less), much of the range of motion was not well stabilized, especially during eccentric movements. The sum of the EMGs from biceps brachii, brachioradialis and brachialis showed a pattern opposite to that expected for a stretch reflex; there was an upward trend in the EMG as the elbow was flexed and a downward trend as the elbow was extended. There was little change in the shape of this EMG-angle relationship with either direction or velocity. The individual EMG-angle relationships were distinctive for each of these three elbow flexor muscles in four of the six subjects; in the remaining two, biceps was distinctive, but brachioradialis and brachialis appeared to be coupled. Although the EMGs of individual muscles were modulated over the angular range, no consistent stretch reflexes could be seen in the individual records. Thus, we could find no clear evidence for stretch reflex stabilization of human subjects maintaining a constant effort. Rather, muscle torque appears to be reflexly modulated across a much used portion of the elbow's angular range so that any appreciable stabilizing stiffness that is sustained for more than fractions of a second is associated with a change in effort.  相似文献   

20.
The effect of exercise-induced arterial hypoxemia (EIAH) on quadriceps muscle fatigue was assessed in 11 male endurance-trained subjects [peak O2 uptake (VO2 peak) = 56.4 +/- 2.8 ml x kg(-1) x min(-1); mean +/- SE]. Subjects exercised on a cycle ergometer at >or=90% VO2 peak) to exhaustion (13.2 +/- 0.8 min), during which time arterial O2 saturation (Sa(O2)) fell from 97.7 +/- 0.1% at rest to 91.9 +/- 0.9% (range 84-94%) at end exercise, primarily because of changes in blood pH (7.183 +/- 0.017) and body temperature (38.9 +/- 0.2 degrees C). On a separate occasion, subjects repeated the exercise, for the same duration and at the same power output as before, but breathed gas mixtures [inspired O2 fraction (Fi(O2)) = 0.25-0.31] that prevented EIAH (Sa(O2) = 97-99%). Quadriceps muscle fatigue was assessed via supramaximal paired magnetic stimuli of the femoral nerve (1-100 Hz). Immediately after exercise at Fi(O2) 0.21, the mean force response across 1-100 Hz decreased 33 +/- 5% compared with only 15 +/- 5% when EIAH was prevented (P < 0.05). In a subgroup of four less fit subjects, who showed minimal EIAH at Fi(O2) 0.21 (Sa(O2) = 95.3 +/- 0.7%), the decrease in evoked force was exacerbated by 35% (P < 0.05) in response to further desaturation induced via Fi(O2) 0.17 (Sa(O2) = 87.8 +/- 0.5%) for the same duration and intensity of exercise. We conclude that the arterial O2 desaturation that occurs in fit subjects during high-intensity exercise in normoxia (-6 +/- 1% DeltaSa(O2) from rest) contributes significantly toward quadriceps muscle fatigue via a peripheral mechanism.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号