首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
C. Remondi, F. Sesti, E. Bonanno, A. Pietropolli and E. Piccione
Diagnostic accuracy of liquid‐based endometrial cytology cytology in the evaluation of endometrial pathology in postmenopausal women Objective: The aim of this study was to compare liquid‐based endometrial cytology with hysteroscopy and endometrial biopsy regarding its diagnostic accuracy in a series of postmenopausal women with abnormal uterine bleeding (AUB) or asymptomatic women with thickened endometrium assessed by transvaginal ultrasound as a screening procedure. Methods: Inclusion criteria were: menopausal status; the presence of AUB and/or thickened endometrium assessed by ultrasound (cut‐off 4 mm); a normal Papanicolaou (Pap) smear; and no adnexal pathology at ultrasound. Exclusion criteria were: previous endometrial pathology; and previous operative hysteroscopy. Of 768 postmenopausal women referred to our general gynaecology clinics, 121 fulfilled the inclusion criteria and were recruited to the trial. Twenty‐one refused to participate. Cytological sampling was carried out by brushing the uterine cavity using the Endoflower device with no cervical dilation and the vial was processed using a ThinPrep® 2000 automated slide processor. The slides were stained using a Pap method. Results: In 98 cases with histological biopsies, endometrial cytology detected five cases of endometrial carcinoma, 10 of atypical hyperplasia and 47 of non‐atypical hyperplasia; 36 cases were negative. In two cases cytology was inadequate because of uterine cervical stenosis. Taking atypical hyperplasia or worse as a positive test and outcome, the diagnostic accuracy of the endometrial cytology was 93.5%, with a sensitivity of 92% and specificity of 95%, a positive predictive value of 73% and a negative predictive value of 99%. All the carcinomas were detected by cytology. Only 42% of women with a positive diagnosis were symptomatic. The cytological sampling was well tolerated by all patients. No complication was registered. Conclusions: Liquid‐based endometrial cytology can be considered an useful diagnostic method in the detection of endometrial pathology as a first‐line approach, particularly if associated with transvaginal ultrasound.  相似文献   

2.
OBJECTIVE: To determine the utility of imprint cytology (IC) in providing an early presumptive diagnosis of clinically suspected cervical carcinoma. STUDY DESIGN: A total of 219 clinically suspicious cervical cancer cases underwent Pap test, punch biopsy and IC at the same sitting. Correlations were performed between these diagnostic modalities to determine the sensitivity and specificity of IC in diagnosis of cervical cancer. RESULTS: The overall accuracy of IC in detecting cervical cancers was 96.2%. About 78% of squamous cell carcinomas (SCC), 60% of adenocarcinomas and 100% of small cell carcinoma could be accurately typed on imprints. Twelve malignant lesions were diagnosed on IC among 26 unsatisfactory biopsies. Although there was no false positive result, 3.5% false negative diagnoses were given on IC. The sensitivity and specificity of imprint smear cytology to detect malignancy was 96.2% and 100%. Agreement between imprint cytology and Pap smear diagnosis of malignancy was 95.3%. kappa Statistics revealed excellent agreement between imprints and biopsies and between imprints and Pap smears in diagnosis of malignant lesions. CONCLUSION: IC can be used as an adjunctive technique for an early and reliable preliminary presumptive diagnosis of cancer of the uterine cervix.  相似文献   

3.
OBJECTIVE: Common bile duct (CBD) brushings have been recognized as a technique of moderate sensitivity and high specificity in identifying carcinoma of the ampulla and pancreatico-biliary regions. This study evaluated the increase in sensitivity of this technique using the ThinPrep technique of specimen preparation when compared with conventional cytology smears. METHODS: A total of 113 bile duct brushings were included in the study (38 conventional smears and 75 slides prepared using the ThinPrep technique). All slides were reviewed by one cytologist. Five categories of reporting were used: inadequate, negative, atypia, suspicious and malignant. RESULTS: The inadequate category of reporting disappeared in the ThinPrep group with improved specimen fixation and preparation and hence reduced artefact. Sensitivity of diagnosis of malignancy increased from 39% in conventional smears to 53% in the ThinPrep group. Specificity, positive and negative predictive values and accuracy were 100%, 100%, 60% and 68% for conventional smears and were 100%, 100%, 60% and 72%, respectively, for ThinPrep specimens. CONCLUSIONS: ThinPrep technique was associated with increased sensitivity of diagnosis, in part due to improved specimen fixation and reduced artefact. Cytology of bile duct brushings is an important diagnostic tool for sites from which it can be difficult to obtain a histology biopsy. It may therefore provide the only opportunity for tissue diagnosis of carcinoma from these sites, hence the importance of optimizing sensitivity.  相似文献   

4.

Background

In previous decades, chromogranin A (CgA) has been demonstrated to be the most promising biomarker for the diagnosis of neuroendocrine tumors (NETs), but its diagnostic value is still controversial. This meta-analysis aimed to estimate the potential diagnostic value of circulating CgA for NETs.

Methods

We collected relevant studies from several electronic databases as well as from reference lists. Diagnostic indices of CgA were pooled with random effects models. Pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR) and summary receiver operating characteristic (SROC) curves for the diagnosis of NETs were used to estimate the overall diagnostic efficiency.

Results

Through a search strategy, 13 studies met the inclusion criteria and were included. These studies contained 1260 patients with NETs and 967 healthy controls in the total sample. As a result, the overall sensitivity, specificity and diagnostic odds ratio (DOR) were 0.73 (95% CI: 0.71 to 0.76), 0.95 (95% CI: 0.93 to 0.96) and 56.29 (95% CI: 25.27 to 125.38), respectively, while the summary positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 14.56 (95% CI: 6.62 to 32.02) and 0.26 (95% CI: 0.18 to 0.38), respectively. In addition, the area under the curve (AUC) of the circulating CgA in the diagnosis of NETs was 0.8962.

Conclusions

These data demonstrate that circulating CgA is an efficient biomarker for the diagnosis of NETs with high sensitivity and specificity, which indicates that it may be helpful for the clinical management of NETs. However, further studies are needed to clarify this issue.  相似文献   

5.
OBJECTIVE: To examine cells that were retained on sampling devices used to collect ThinPrep (Cytyc Corp., Boxborough, Massachusetts, U.S.A) Pap smears in order to evaluate both the number and significance of cells that are routinely discarded with these devices after liquid-based specimens are collected. STUDY DESIGN: One hundred Pap smears from 100 women were prospectively procured after gynecologic Pap smears were collected for the ThinPrep Pap test. The sampling end of the collection devices was cut off and placed in a vial that contained SUREPATH preservative fluid (TriPath Imaging, Inc., Burlington, North Carolina, U.S.A). The residual cell samples were processed using the SurePath PREPSTAIN slide processor (TriPath). A single liquid-based slide was prepared from the sampling devices from each of the 100 specimens collected. The slides produced from the discarded devices were reviewed for the following: squamous cells, endocervical component, epithelial cell abnormalities and miscellaneous findings. The slides prepared from the "throw-away" (TA) material were subsequently compared with the primary ThinPrep Pap smear slide. RESULTS: Twenty-five percent of the TA samples had an equal or greater number of squamous cells per high-power microscopic field when compared to the primary ThinPrep slide, with 8% of the TA slides demonstrating greater overall cellularity. An endocervical component was present on 27 of 66 cervical samples (40.9%). Three of five cases (60%) interpreted as atypical squamous cells of undetermined significance had similar cells on the TA slides. Two cases of atypical glandular cells of undetermined significance had no abnormal cells on the TA slides. Twelve of 14 cases (85.71%) of low grade squamous intraepithelial lesion contained similar cells on the TA slides. Two of four cases (50%) of high grade squamous intraepithelial lesion also had similar abnormal cells on the TA slides. Miscellaneous findings included 1 case of benign endometrial cells and 4 Candida infections present on both preparations, along with 1 case of Trichomonas vaginalis organisms present on the ThinPrep slide only. In 1 specimen, several multinucleated histiocytic giant cells were present only on the TA slide. CONCLUSIONS: Specimens prepared from TA collecting devices used for the ThinPrep Pap test are less sensitive than the primary specimen for the detection of cervical lesions. This is in contrast to split-sample studies involving ThinPrep and conventional smears. Our study documented the presence of normal and abnormal cells discarded from ThinPrep sampling devices in a high percentage of cases. Discarded abnormal cells on the TA slides were, however, few when compared to the primary specimen, with only 1 exception involving a high grade lesion.  相似文献   

6.
OBJECTIVE: To determine the sensitivity and specificity of liquid-based cytology in a high-risk, unscreened population. STUDY DESIGN: A cross-sectional comparative trial of multiple screening techniques. This report focuses on the performance of liquid-based cytology using biopsy as the standard. RESULTS: In total, 1,997 women were screened. All subjects had a minimum of five cervical biopsies. Of the subjects, 4.3% had CIN 2 on biopsy. The ThinPrep Pap with ASCUS as positive had a sensitivity for CIN 2 of 94% and specificity of 78%; the sensitivity for CIN 3 was 98% and for cancer, 100%. The unsatisfactory rate due to bloody specimens was 7.9% (158/1,997). After reprocessing, the unsatisfactory rate was 0.15% (3/1,997). CONCLUSION: Reprocessing effectively recovers ThinPrep samples otherwise unsatisfactory due to blood and mucus. The ThinPrep Pap test is a highly sensitive screening test when used in a high-risk, unscreened population.  相似文献   

7.

Objective

To assess the value of anaplastic lymphoma kinase for the diagnosis of inflammatory myofibroblastic tumours using a comprehensive meta-analysis.

Methods

We searched the related literature using electronic databases and manual searches. Approximately 454 cases from several countries were included in this analysis. The quality of studies included was assessed by QUADAS (quality assessment of studies of diagnostic accuracy). The diagnostic odds ratio (DOR), positive likelihood ratio (PLR), negative likelihood ratio (NLR), sensitivity and specificity were calculated to assess the role of anaplastic lymphoma kinase in the diagnosis of inflammatory myofibroblastic tumours. The overall test performance was summarised by an SROC (summary receiver operating characteristic curve). The heterogeneity and publication bias were analysed using Meta-regression and Deeks'' test. All data were analysed by Stata 12.0 software.

Results

Eight studies were included according to our inclusion criteria. The overall results for the specificity, sensitivity, PLR, NLR, DOR and area under the curve (AUC) were 0.99 (95% CI 0.82-1.00), 0.67 (95% CI 0.46-0.83), 0.67 (95% CI 0.46-0.83), 60.6 (95% CI 3.3-1112.4), 0.33 (95% CI 0.19-0.60), 181 (95% CI 9-3684) and 0.95 (95% CI 0.93-0.97), respectively, while the specificity, sensitivity, PLR, NLR, DOR and AUC for bladder IMTs were 0.99 (95% CI 0.67-1.00), 0.86 (95% CI 0.58-0.96), 95.6 (95% CI 2.0-4616.2), 0.14 (95% CI 0.04-0.50), 671 (95% CI 16-28913) and 0.99 (95% CI 0.97-0.99), respectively.

Conclusion

The present meta-analysis indicated that anaplastic lymphoma kinase plays a significant role in the differential diagnosis of inflammatory myofibroblastic tumours, particularly for inflammatory myofibroblastic tumours of the urinary bladder.  相似文献   

8.
An Australian trial of ThinPrep: a new cytopreparatory technique   总被引:1,自引:0,他引:1  
To evaluate the sensitivity and suitability of ThinPrep, a new slide preparation technique, 2026 paired cervical cytology slides were examined. After conventional Papanicolaou smears were prepared, the sampling instruments were rinsed in a fluid fixative. ThinPrep slides were then prepared in the laboratory from the surplus cells in the fixative. Compared with the Pap smears, ThinPrep slides were easier and quicker to screen, were inconclusive less often, and had similar rates for detecting abnormalities and infection. There were more unsatisfactory ThinPrep slides and more ThinPrep slides lacked endocervical cells. Both of these shortcomings were found to be linked to the choice of sampling implements. This study, in which a variety of sampling instruments was used, fails to confirm some of the previous claims made for the new technique.  相似文献   

9.
Interferon -gamma release assays (IGRAs) provide a new diagnostic method for Mycobacterium tuberculosis (TB) infection. However, the diagnostic value of IGRAs for extrapulmonary TB (EPTB) has not been clarified. We searched several databases and selected papers with strict inclusion criteria, evaluated the evidence of commercially available IGRAs (QuantiFERON(?) -TB Gold QFT-G or QFT-GIT and T-SPOT(?) .TB) on blood and the tuberculin skin test (TST) using random effects models. Twenty studies with 1711 patients were included. After excluding indeterminate results, pooled sensitivity for the diagnosis of EPTB was 72% [95% confidence interval (CI) 65-79%] for QFT-G or GIT and 90% (95% CI, 86-93%) for T-SPOT; in high-income countries the sensitivity of QFT-G or GIT (79%, 95% CI 72-86%) was much higher than that (29%, 95% CI 14-48%) in low/middle-income countries. Pooled specificity for EPTB was 82% (95% CI 78-87%) for QFT-G or GIT and 68% (95% CI 64-73%) for T-SPOT. Pooled sensitivity of TST from four studies in high-income countries was lower than that of IGRAs. T-SPOT was more sensitive in detecting EPTB than QFT-G or GIT and TST. However, both IGRAs and TST have similar specificity for EPTB. IGRAs have limited value as diagnostic tools to screen and rule out EPTB, especially in low/middle-income countries. The immune status of patients does not affect the diagnostic accuracy of IGRAs for EPTB.  相似文献   

10.
Park IA  Lee SN  Chae SW  Park KH  Kim JW  Lee HP 《Acta cytologica》2001,45(4):525-531
OBJECTIVE: To confirm that the ThinPrep Pap test (TP) is as effective as or more effective than the conventional Papanicolaou smear (CS) in detecting epithelial cell abnormalities in a population with cervical abnormalities. STUDY DESIGN: In a blinded, split-sample, matched-pair study, a CS was prepared using a cytobrush, and then TP slides were prepared from the remainder of the sample. All slides were evaluated as defined and classified by the Bethesda System. The results of the two cytologic tests were compared in 483 women relative to the histologic diagnoses of subsequent colposcopically directed cervical biopsies in 158 cases. RESULTS: The cytologic diagnoses from the two methods agreed exactly in 91.4% of cases. The comparison between the two cytologic diagnoses with reference to the histologic diagnosis of subsequent colposcopically directed cervical biopsies showed that TP was significantly more specific for diagnosing lesions than was CS. The sensitivity of the two methods was equivalent. CONCLUSION: In a population with cervical abnormalities, TP is more specific than and as effective as CS in detecting cervical epithelial cell abnormalities. TP improved the specificity of disease detection by reducing the atypical squamous cells of undetermined significance category and/or false positive cases.  相似文献   

11.

Objective

To determine the accuracy of MR imaging with gadoxetic acid disodium (Gd-EOB-DTPA) for the detection of hepatocelluar carcinoma (HCC).

Materials and Methods

A systematic search was performed in PUBMED, EMBASE, Web of Science, Cochrane Library and the Chinese Biomedical Literature Database up to March 2013 to identify studies about evaluation of Gd-EOB-DTPA enhanced MR imaging in patients suspected of having HCC. The data were extracted to perform heterogeneity test and threshold effect test and to calculate sensitivity, specificity, diagnostic odds ratio, predictive value, and areas under summary receiver operating characteristic curve (AUC).

Results

From 601 citations, 10 were included in the meta-analysis. The methodological quality of the 10 studies was good. Overall HCC: There was significant heterogeneity in the pooled analysis (I2 = 69.4%, P = 0.0005), and the pooled weighted values were determined to be sensitivity: 0.91 (95% confidence interval (CI): 0.89, 0. 93); specificity: 0.95 (95% CI: 0.94, 0.96); diagnostic odds ratio: 169.94 (95% CI: 108.84, 265.36); positive likelihood ratio: 15.75 (95% CI: 7.45, 33.31); negative likelihood ratio: 0.10 (95% CI: 0.06, 0.15). The AUC was 0.9778. HCC in cirrhosis: The estimates were to be sensitivity: 0.91 (95% CI: 0.88, 0.93); specificity: 0.93 (95% CI: 0.89, 0.95); diagnostic odds ratio: 234.24 (95% CI: 33.47, 1639.25); positive likelihood ratio: 15.08 (95% CI: 2.20, 103.40); negative likelihood ratio: 0.08 (95% CI: 0.03, 0.21). The AUC was 0.9814. ≤20 mm HCC: The AUC was 0.9936. There was no notable publication bias.

Conclusions

This meta-analysis suggests that MR imaging with Gd-EOB-DTPA has high diagnostic accuracy for the detection of HCC, especially for ≤20 mm HCC. This technique shows good prospect in diagnosis of HCC.  相似文献   

12.

Background

Previous studies have reported that natriuretic peptides in the blood and pleural fluid (PF) are effective diagnostic markers for heart failure (HF). These natriuretic peptides include N-terminal pro-brain natriuretic peptide (NT-proBNP), brain natriuretic peptide (BNP), and midregion pro-atrial natriuretic peptide (MR-proANP). This systematic review and meta-analysis evaluates the diagnostic accuracy of blood and PF natriuretic peptides for HF in patients with pleural effusion.

Methods

PubMed and EMBASE databases were searched to identify articles published in English that investigated the diagnostic accuracy of BNP, NT-proBNP, and MR-proANP for HF. The last search was performed on 9 October 2014. The quality of the eligible studies was assessed using the revised Quality Assessment of Diagnostic Accuracy Studies tool. The diagnostic performance characteristics (sensitivity, specificity, and other measures of accuracy) were pooled and examined using a bivariate model.

Results

In total, 14 studies were included in the meta-analysis, including 12 studies reporting the diagnostic accuracy of PF NT-proBNP and 4 studies evaluating blood NT-proBNP. The summary estimates of PF NT-proBNP for HF had a diagnostic sensitivity of 0.94 (95% confidence interval [CI]: 0.90–0.96), specificity of 0.91 (95% CI: 0.86–0.95), positive likelihood ratio of 10.9 (95% CI: 6.4–18.6), negative likelihood ratio of 0.07 (95% CI: 0.04–0.12), and diagnostic odds ratio of 157 (95% CI: 57–430). The overall sensitivity of blood NT-proBNP for diagnosis of HF was 0.92 (95% CI: 0.86–0.95), with a specificity of 0.88 (95% CI: 0.77–0.94), positive likelihood ratio of 7.8 (95% CI: 3.7–16.3), negative likelihood ratio of 0.10 (95% CI: 0.06–0.16), and diagnostic odds ratio of 81 (95% CI: 27–241). The diagnostic accuracy of PF MR-proANP and blood and PF BNP was not analyzed due to the small number of related studies.

Conclusions

BNP, NT-proBNP, and MR-proANP, either in blood or PF, are effective tools for diagnosis of HF. Additional studies are needed to rigorously evaluate the diagnostic accuracy of PF and blood MR-proANP and BNP for the diagnosis of HF.  相似文献   

13.
14.
《Endocrine practice》2009,15(4):335-342
ObjectiveTo report a meta-analysis of late-night salivary cortisol testing for the diagnosis of Cushing syndrome.MethodsMEDLINE and EMBASE computer databases were searched to identify relevant articles published between January 1950 and December 2007. The search strategy used the following medical subject headings and keywords: cortisol, Cushing or Cushing’s, saliva, salivary, late-night, nocturnal, and nighttime. The results were limited to studies in humans older than 18 years. Titles and abstracts of all articles, as well as full text of relevant articles, were reviewed. Sensitivity, specificity, likelihood ratio positive, likelihood ratio negative, and diagnostic odds ratio were extracted by 2 authors. Discrepancies were resolved by mediation and discussion with a third author.ResultsSeven articles contained sufficient information to be included in the analysis. A total of 947 patients (339 with Cushing syndrome) were identified. Pooled data from the 7 studies revealed a sensitivity of 92% (95% confidence interval [CI], 88%-94%), specificity of 96% (95% CI, 94%-97%), and diagnostic odds ratio of 311 (95% CI, 92-1059). Likelihood ratio positive was 21 (95% CI, 1043), with a likelihood ratio negative of 0.08 (95% CI, 0.02-0.32). Inconsistencies for each of these results measured by the I2 statistic ranged from moderate to high.ConclusionThis analysis demonstrates that latenight salivary cortisol has excellent diagnostic characteristics and as such, is a robust, convenient test for screening and diagnosis of Cushing syndrome. (Endocr Pract. 2009;15:335-342)  相似文献   

15.
Objective:  To compare the accuracy of intraoperative fine needle aspiration cytology samples prepared by the ThinPrep method to conventional cytological methods. Specimen adequacy and turn around time (TAT) were also assessed.
Methods:  Fifty consecutive fresh tumours submitted for histological analysis were aspirated and each prepared as follows: (i) direct smear with H&E stain, (ii) direct smear with Pap stain, (iii) ThinPrep slide with H&E stain, and (iv) ThinPrep slide with Pap stain. The slides were randomly distributed to three cytopathologists for interpretation. The quality of the preparation, the diagnosis and the time needed for interpretation were recorded.
Results:  Accuracy was measured as the percentage of absolute agreement between the cytological and the histopathological diagnoses of the lesions. Histologically, there were 43 malignant and six benign lesions and one atypical lipoma. The TAT began when the slides/cytolyte specimens arrived at the lab and ended with the pathologist's diagnosis.
Conclusions:  In terms of accuracy and specimen adequacy, ThinPrep slides with Pap stain is the best procedure. This advantage however is offset by the longer testing time.  相似文献   

16.
17.
OBJECTIVE: To compare automated interactive screening using the ThinPrep Imaging System with independent manual primary screening of 12,000 routine ThinPrep slides. STUDY DESIGN: With the first 6,000 cases, the Review Scopes (RS) screening results from the 22 fields of view (FOV) only were compared to independent manual primary screening. In the next 6,000 cases, any abnormality detected in the 22 FOV resulted in full manual screening on the cytotechnologist's own microscope. Sensitivity and specificity together with their 95% CIs were calculatedfor each method. RESULTS: In the first set of 6, 000 cases, diagnostic sensitivity and specificity of the imager were 85.19% and 96.67%, respectively. The diagnostic sensitivity and specificity of manual primary screening were 89.38% and 98.42%. This highersensitivity and specificity of manual primary screening were found to be statistically significant. The second set of 6,000 cases demonstrated no significant statistical difference in sensitivity or specificity between the sets of data. CONCLUSION: The results from our study show that the sensitivity and specificity of the imager technology are equivalent to those of manual primary screening. The system is ideally suited to the rapid screening of negative cases, allowing increased laboratory productivity and greater throughput of cases on a daily basis.  相似文献   

18.
MiR-141 has gradually demonstrated its value in the diagnosis of prostate cancer. However, the diagnostic parameters applied in previous studies were different. This systematic review was conducted to explore the diagnostic value of miR-141 in prostate cancer. A comprehensive search of related literature in PubMed, Medline, the Cochrane Library and Embase databases was performed. Seven studies were included which assessed the diagnostic value of miR-141 in patients with prostate cancer up to October 31, 2019. Meta-disc version 1.4 and STATA software version 12.0 were used to analyze the data. The pooled sensitivity and specificity were 0.70 (95% CI 0.64~0.75) and 0.73 (95% CI 0.64~0.80), respectively. The positive likelihood ratio (PLR) was 2.88 (95% CI 1.40~5.93), and negative likelihood ratio (NLR) was 0.38 (95% CI 0.20~0.71). The pooled diagnostic odds ratio (DOR) of miR-141 for prostate cancer was observed to be 9.94 (95% CI: 2.55~38.80). The summary area under the receiver operating characteristic (ROC) curve was 0.83 (95% CI: 0.79~0.86). The results of meta-regression suggested that heterogeneity was mainly derived from patient age. The Fagan nomogram results showed a significant increase when correlating miR-141 with the diagnosis of prostate cancer. This meta-analysis suggests that miR-141 has a high diagnostic value for prostate cancer. In future, large-scale prospective studies will be done to verify and evaluate this result.  相似文献   

19.

Background

Various studies have assessed the diagnostic accuracy of EGFR mutation-specific antibodies in non-small cell lung cancer (NSCLC). We performed a meta-analysis of existing data to investigate the diagnostic value of mutation-specific antibodies for detection of EGFR mutations in NSCLC.

Methods

We systematically retrieved relevant studies from PubMed, Web of Knowledge, and Google Scholar. Data from studies that met the inclusion criteria were extracted for further exploration of heterogeneity, including calculation of the average sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and analysis of SROC(summary receiver operating characteristic) curves.

Results

Fifteen studies met our inclusion criteria. A summary of the meta-analysis of the efficacy of the anti-E746-A750 antibody was as follows: sensitivity, 0.60 (95% CI, 0.55–0.64); specificity, 0.98 (95% CI, 0.97–0.98); PLR, 33.50 (95% CI, 13.96–80.39); NLR, 0.39 (95% CI, 0.30–0.51) and DOR, 111.17 (95% CI, 62.22–198.63). A similar meta-analysis was performed for the anti-L858R antibody with results as follows: sensitivity, 0.76 (95% CI, 0.71–0.79); specificity, 0.96 (95% CI, 0.95–0.97); PLR, 24.42 (95% CI, 11.66–51.17); NLR, 0.22 (95% CI, 0.12–0.39) and DOR, 126.66 (95% CI, 54.60–293.82).

Conclusion

Immunohistochemistry alone is sufficient for the detection of EGFR mutations if the result is positive. Molecular-based analyses are necessary only if the anti-E746-A750 antibody results are negative. Immunohistochemistry seems more suitable for clinical screening for EGFR mutations prior to molecular-based analysis.  相似文献   

20.

Background

MicroRNAs (miRNAs) have been reported to be aberrantly expressed in patients with cancer. Many studies have shown that circulating miRNAs could play potential roles as diagnostic and prognostic biomarkers of cancers. The aim of this meta-analysis is to summarize the role of circulating miR-21 as a biomarker in patients with a variety of carcinomas.

Material and methods

Eligible studies were identified and assessed for quality through multiple search strategies. For diagnostic meta-analysis, the sensitivity, specificity, and other measures of miR-21 in the diagnosis of cancer were pooled using bivariate random-effects approach models. For prognostic meta-analysis, pooled hazard ratios (HRs) of circulating miR-21 for survival were calculated.

Results

A total of 36 studies dealing with various carcinomas were included for the systemic review. Among them, 23 studies were finally enrolled in the global meta-analysis (17 studies for diagnosis and 6 studies for prognosis). For diagnostic meta-analysis, the overall pooled results for sensitivity, specificity, positive likelihood ratio (LRP), negative likelihood ratios (LRN) and diagnostic odds ratio (DOR) were 75.7% (95% CI: 67.1%–82.6%), 79.3% (95% CI: 74.2%–83.5%), 3.65 (95% CI: 2.83–4.70), 0.31 (95% CI: 0.22–0.43), and 11.88 (95% CI: 6.99–20.19), respectively. For prognostic meta-analysis, the pooled HR of higher miR-21 expression in circulation was 2.37 (95% CI: 1.83–3.06, P < 0.001), which could significantly predict poorer survival in general carcinomas. Importantly, subgroup analysis suggested that higher expression of miR-21 correlated with worse overall survival (OS) significantly in carcinomas of digestion system (HR, 5.77 [95% CI: 2.65–12.52]).

Conclusions

Our findings suggest that circulating miR-21 may not suitable to be a diagnostic biomarker, but it has a prognostic value in patients with cancer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号