首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Objectives

To report our experience with the recently introduced 34?mm Evolut transcatheter aortic valve replacement (TAVR) prosthesis.

Background

A larger TAVR prosthesis has become available for the treatment of aortic stenosis (AVS) in larger native aortic annuli (up to 30?mm). Outcomes with this new device are still unreported.

Results

The first 25 transfemoral TAVRs performed by our team with the self-expandable 34?mm Evolut are presented. The majority of patients were male (84%) with a mean age of 81.3?±?5.6 years, a median logistic euro-SCORE of 14.7 (5.4-61.0), and a computed tomography measured mean perimeter-derived aortic annulus diameter of 27.1?±?1.4?mm (min. 25.0–max. 31.2?mm). We implanted one 34?mm Evolut in all patients. Median operative time and radiation time were 68.5 and 12.4?min respectively. To optimise final valve position and haemodynamic performance, at least one complete re-sheathing and re-positioning of the same valve was reported in 33.2%. New permanent pacemaker implantation (PPMI) was necessary in 28.5%. At Receiver Operating Characteristic (ROC) analysis, a minimal diameter of the left ventricular outflow tract <21.9?mm was a significant predictor for PPMI (specificity 82%; sensitivity 83%; p?=?0.005; Area Under the Curve (AUC)?=?0.9). Length of stay in hospital was 9.2?±?5.8 days and no in-hospital death was reported. At discharge, grade 1?+?para-valvular regurgitation was present in 32%, and no regurgitation in the remaining patients. Device success and early safety were 100% and 92% respectively.

Conclusions

TAVR with the 34?mm Evolut prosthesis has shown satisfactory acute outcomes. Although results are consistent with those observed with smaller Evolut prostheses, a trend for a higher PPMI rate has been noticed and could derive from a higher oversizing rate.
  相似文献   

2.

Background

Severe aortic valve stenosis is one of the most common cause of mortality in adult patients affected with metabolic syndrome, a condition associated with an active inflammatory process involving also mast cells and their mediators, in particular tryptase. The aim of this study was to characterize the possible long-term prognostic role of tryptase in severe aortic valve stenosis.

Case presentation

The baseline serum tryptase was measured in 5 consecutive patients admitted to our Hospital to undergo aortic valve replacement for severe acquired stenosis. Within 2 years after, the patients were evaluated for the occurrence of major cardiovascular events (MACE). The tryptase measurements were higher in patients experiencing MACE (10.9, 11.7 and 9.32 ng/ml) than in non-MACE ones (5.69 and 5.58 ng/ml).

Conclusions

In patients affected with severe aortic stenosis, baseline serum tryptase may predict occurence of MACE. Further studies are needed to demonstrate the long-term prognostic role of this biomarker.
  相似文献   

3.

Introduction

The Venus p?valve (MedTech, Shanghai, China) is a self-expanding percutaneous heart valve designed to be implanted in a native patched right ventricle outflow tract. The worldwide clinical experience with this valve is just beginning and the results have so far been encouraging. We present our initial early experience implanting the Venus p?valve in the native right ventricle outflow tract of patients with Tetralogy of Fallot repaired with a transannular patch.

Methods

In 10 selected patients a procedure for percutaneous pulmonary valve implantation was performed using the Venus p?valve. The patients mean age was 32 years (13–57), mean weight 59.6?kg (40–80). All patients had Tetralogy of Fallot with moderate to severe pulmonary regurgitation and an indication for pulmonary valve replacement.

Results

The implantation procedure was successful in all the patients resulting in an immediately functional valve. No procedure-related complications were observed. Follow-up after 12 months (4–21) resulted in an improvement in NYHA class. There was a reduction of the mean right ventricle diastolic volume from 139?ml/m2 (105–179) to 78?ml/m2 (65–100) and improvement in the regurgitation fraction from 42% (29–58) to 1% (0–5), as seen on routine cardiac magnetic resonance 6 months after the implantation. No stent fractures have been observed so far.

Conclusion

Percutaneous pulmonary valve implantation with the Venus p?valve resulted in a safe and effective procedure. The valve has predictable and sustained functional competence, resulting in clinical improvement in the patients.
  相似文献   

4.

Aims

This study was designed to gain insight into the patient characteristics, results and possible complications of ablation procedures for symptomatic idiopathic premature ventricular complexes (PVC) and idiopathic ventricular tachycardia (VT).

Methods

Data were collected from all patients who underwent radiofrequency catheter ablation for symptomatic PVCs and idiopathic VT in the Catharina Hospital between 1 January 2011 and 31 December 2015. The procedural endpoint was elimination or non-inducibility of the clinical arrhythmia. Successful sustained ablation was defined as the persistent elimination of at least 80% of the PVCs or the absence of VTs at follow-up. In case of suspected PVC-induced cardiomyopathy, the systolic left ventricular function was reassessed 3 months post procedure.

Results

Our cohort consisted of 131 patients who underwent one or more ablation procedures; 99 because of symptomatic premature ventricular complexes, 32 because of idiopathic VT. In total 147 procedures were performed. The procedural ablation success rate was 89%. Successful sustained ablation rate was 82%. Eighteen (13.2%) patients had suspected PVC-induced cardiomyopathy. In 15 of them (83%), successful sustained ablation was achieved and the left ventricular ejection fraction improved from a mean of 39% (±8.8) to 55.4% (±8.1). Most arrhythmias originated from the right ventricular outflow tract (60%) or aortic cusps (13%). Complications included three tamponades.

Conclusion

Catheter ablation therapy for idiopathic ventricular arrhythmias is very effective with a sustained success rate of 82%. In patients with PVC-induced cardiomyopathy, it leads to improvement of systolic left ventricular function. However, risk for complications is not negligible, even in experienced hands.
  相似文献   

5.

Background

Adverse events from Melody valve implantation may be catastrophic. To date a role for three dimensional rotational angiography of the aortic root (3DRAA) during Melody valve implantation has not been established.

Objectives

To describe the role of 3DRAA in the assessment of Melody valve candidacy and to demonstrate that it may improve outcomes.

Methods

All patients who underwent cardiac catheterisation for Melody valve implantation and 3DRAA between August 2013 and February 2015 were reviewed.

Results

31 patients had 3DRAA with balloon sizing. Ten were deemed not Melody candidates (5 coronary compression, 2 aortic root distortion with cusp flattening, 2 RVOT was too large, and 1 had complex branch stenosis and a short landing zone). Of the 21 patients who were Melody candidates, 12 had conduits, 6 prosthetic valves and 3 native RVOTs. In patients with conduits, the technique of stenting the conduit prior to dilation was used after measuring the distance between the conduit and the coronary arteries on 3DRAA. In the Melody patients, we had 100% procedural success and no serious adverse events (coronary compression, tears, stent fracture or endocarditis).

Conclusion

As a tool for case selection, 3DRAA may facilitate higher procedural success and decreased risk of serious adverse events. Furthermore, 3D rotational angiography allows stenting of the conduit prior to dilation, which may prevent tears and possibly endocarditis.
  相似文献   

6.

Background

Heart valve surgery outcomes are unknown in middle-income countries and thus cannot be used in health system decision making processes. This study estimated in-hospital mortality and medium and long-term survival.

Methods

This was a retrospective study of 78,806 patients who underwent heart valve surgery between 2001 and 2007 in Brazil. Two national databases were used, the Hospital Information System and the Mortality Information System. Kaplan-Meier survival analysis and log-rank tests were performed. Maximum and median follow-up was 7.7 and 2.8 years, respectively (0.002–7.707).

Results

Valve replacement accounted for 69.1% of procedures performed. Mitral stenosis, the most common valve injury, represented 38.9% of the total. In 94.7% of mitral stenosis patients, aetiology was rheumatic heart disease. In-hospital mortality was 7.6% and was higher for women, for patients who had undergone concomitant coronary artery bypass grafting (CABG) and for the elderly. Overall survival was 69.9% at the end of follow-up. Survival was worst among elderly, male and concomitant CABG patients (P<0.001).

Conclusions

Rheumatic heart disease is still a major public health problem in Brazil. In-hospital mortality and global survival rates of patients who have undergone heart valve surgery were less satisfactory than those reported in high-income countries. The findings of this study can contribute to guiding decision making processes in middle-income countries similar to Brazil and others concerned with improving the quality of care.
  相似文献   

7.

Background

Type 2 diabetes mellitus (T2DM) is strongly related to the in-hospital and short-term prognosis in patients with cardiovascular diseases needing surgical or invasive interventions. How T2DM might influence the treatment of aortic stenosis (AS) has not been completely elucidated for surgical aortic valve replacement (SAVR) or transcatheter aortic valve implantation (TAVI). The aims of this study were: (1) to describe the use of aortic valve replacement procedures (TAVI and SAVR) among hospitalized patients with and without T2DM; and (2) to identify factors associated with in hospital mortality (IHM) among patients undergoing these procedures.

Methods

We analyzed data from the Spanish National Hospital Discharge Database between January 1, 2014 and December 31, 2015 for patients aged ≥ 40 years. We selected patients whose medical procedures included TAVI (ICD-9-CM codes 35.05, 35.06) and SAVR (ICD-9-CM codes 35.21, 35.22). We stratified each cohort by diabetes status: T2DM (ICD-9-CM codes 250.x0, 250.x2) and no diabetes. We retrieved data about specific comorbidities, risk factors, procedures, and specific in-hospital postoperative complications. Hospital outcome variables included IHM, and length of hospital stay (LOHS).

Results

We identified a total of 2141 and 16,013 patients who underwent TAVI (n = 715; 33.39% with T2DM) and SAVR (n = 4057; 25.33% with T2DM). In patients who underwent TAVI we found no differences in IHM (3.64% in T2DM vs. 5.12% in non-T2DM, p = 0.603). In the cohort of SAVR, mean LOHS was significantly lower in patients with T2DM than in non-diabetic patients (13.77 vs. 17.27 days). IHM was lower in patients with T2DM (4.36% vs. 6.31%, p < 0.01). After multivariable adjustment for both procedures, patients with T2DM had significantly lower IHM than patients without diabetes (adjusted OR 0.60; IC 95% 0.37–0.99 for TAVI and adjusted OR 0.80; IC 95% 0.66-0-96 for SAVR).

Conclusions

T2DM diabetic patients with AS undergoing a valvular replacement procedure through SAVR or TAVI did not have a worse prognosis compared to non-diabetic patients during hospitalization, showing lower IHM after multivariable adjustment. However, given the limitations of administrative data more prospective studies and clinical trials aimed at evaluating the influence of these procedures in diabetic patients with AS are needed.
  相似文献   

8.

Background and objectives

Periprosthetic aortic regurgitation (PPR) after transcatheter aortic valve implantation (TAVI) remains an important issue associated with impaired long-term outcomes. The current randomised study aims to evaluate potential differences between the balloon-expandable Edwards SAPIEN-3 and the self-expanding Medtronic CoreValve system with the main focus on post-TAVI PPR by means of novel imaging endpoints, and an additional focus on other clinical endpoints.

Endpoints

The primary endpoint of this study is quantitative assessment of the severity of post-procedural PPR using cardiac magnetic resonance imaging. Several other novel imaging modalities (X-ray contrast angiography, echocardiography) are used as secondary imaging modalities for the assessment of PPR following TAVI. Secondary objectives of the study include clinical outcomes such as cerebral and kidney injury related to TAVI, and quality of life.

Methods and design

The ELECT study is a single-centre, prospective, two-armed randomised controlled trial. For the purpose of this study, 108 consecutive adult patients suitable for transfemoral TAVI will be randomly allocated to receive the SAPIEN-3 (n = 54) or the CoreValve system (n = 54).

Discussion

The ELECT trial is the first randomised controlled trial to quantitatively compare the extent of post-TAVI PPR between the SAPIEN-3 and CoreValve. Furthermore, it will evaluate potential differences between the two prostheses with regard to mid-term clinical outcome and quality of life.
  相似文献   

9.

Background

Due to the limited number of experimental studies that mechanically characterise human atherosclerotic plaque tissue from the femoral arteries, a recent trend has emerged in current literature whereby one set of material data based on aortic plaque tissue is employed to numerically represent diseased femoral artery tissue. This study aims to generate novel vessel-appropriate material models for femoral plaque tissue and assess the influence of using material models based on experimental data generated from aortic plaque testing to represent diseased femoral arterial tissue.

Methods

Novel material models based on experimental data generated from testing of atherosclerotic femoral artery tissue are developed and a computational analysis of the revascularisation of a quarter model idealised diseased femoral artery from a 90% diameter stenosis to a 10% diameter stenosis is performed using these novel material models. The simulation is also performed using material models based on experimental data obtained from aortic plaque testing in order to examine the effect of employing vessel appropriate material models versus those currently employed in literature to represent femoral plaque tissue.

Results

Simulations that employ material models based on atherosclerotic aortic tissue exhibit much higher maximum principal stresses within the plaque than simulations that employ material models based on atherosclerotic femoral tissue. Specifically, employing a material model based on calcified aortic tissue, instead of one based on heavily calcified femoral tissue, to represent diseased femoral arterial vessels results in a 487 fold increase in maximum principal stress within the plaque at a depth of 0.8 mm from the lumen.

Conclusions

Large differences are induced on numerical results as a consequence of employing material models based on aortic plaque, in place of material models based on femoral plaque, to represent a diseased femoral vessel. Due to these large discrepancies, future studies should seek to employ vessel-appropriate material models to simulate the response of diseased femoral tissue in order to obtain the most accurate numerical results.
  相似文献   

10.

Background

We report a case of pulmonary sarcoma which is a rare cause of the common symptom of dyspnea.

Case presentation

A fifty-one year old previously healthy male presented to the emergency room with complaints of dyspnea on exertion. A cardiac workup including an exercise stress test was negative but an echocardiography showed pulmonary stenosis. Cardiac MRI showed a large mass extending from the pulmonic valve to both the right and left pulmonary arteries suggestive of sarcoma. A complete resection and repair of the pulmonary artery was done and adjuvant chemotherapy with doxorubicin and ifosfamide was recommended. The patient is currently disease free after eighteen months.

Conclusion

Pulmonary artery sarcomas are a difficult diagnosis. The diagnosis may remain elusive for some time until the proper imaging techniques are utilized to make a diagnosis. Earlier and accurate diagnosis may lead to earlier interventions and improve survival.
  相似文献   

11.

Background

Hydrocephalus is a medical condition consisting of an abnormal accumulation of cerebrospinal fluid within the brain. A catheter is inserted in one of the brain ventricles and then connected to an external valve to drain the excess of cerebrospinal fluid. The main drawback of this technique is that, over time, the ventricular catheter ends up getting blocked by the cells and macromolecules present in the cerebrospinal fluid. A crucial factor influencing this obstruction is a non-uniform flow pattern through the catheter, since it facilitates adhesion of suspended particles to the walls. In this paper we focus on the effects that tilted holes as well as conical holes have on the flow distribution and shear stress.

Methods

We have carried out 3D computational simulations to study the effect of the hole geometry on the cerebrospinal fluid flow through ventricular catheters. All the simulations were done with the OpenFOAM® toolbox. In particular, three different groups of models were investigated by varying (i) the tilt angles of the holes, (ii) the inner and outer diameters of the holes, and (iii) the distances between the so-called hole segments.

Results

The replacement of cylindrical holes by conical holes was found to have a strong influence on the flow distribution and to lower slightly the shear stress. Tilted holes did not involve flow distribution changes when the hole segments are sufficiently separated, but the mean shear stress was certainly reduced.

Conclusions

The authors present new results about the behavior of the fluid flow through ventricular catheters. These results complete earlier work on this topic by adding the influence of the hole geometry. The overall objective pursued by this research is to provide guidelines to improve existing commercially available ventricular catheters.
  相似文献   

12.

Objectives

N-terminal B?type natriuretic peptide (NT-proBNP) is an important biomarker for the detection of heart failure. Adults with congenital heart disease (ACHD) and a prosthetic heart valve are at risk for heart failure. This study aimed to determine the value of NT-proBNP in ACHD patients with a prosthetic valve and investigate its relationship with cardiac function and exercise capacity.

Methods

In this multi-centre cross-sectional observational study, data regarding medical history, echocardiography, exercise testing (VO2peak) and laboratory blood evaluation (including NT-proBNP) were collected in ACHD patients with a single prosthetic valve (either homografts, heterografts or mechanical valves).

Results

A total of 306 ACHD patients with pulmonary valve replacement (PVR, n = 139), aortic valve replacement (n = 141), mitral valve replacement (n = 21) or tricuspid valve replacement (n = 5) were investigated. The majority of patients (77?%) were in NYHA class I or II. Elevated NT-proBNP levels (cut-off ≥125 pg/ml) were found in 50?% of the patients, with the highest levels in patients with mitral valve replacements. In this study population, NT-proBNP levels were associated with gender (p = 0.029) and VO2max (p < 0.001). In PVR patients, NT-proBNP levels were associated with lower VO2peak, also after adjustment for age, gender and age at valve replacement in a multivariate model (p = 0.015).

Conclusions

In patients with ACHD and a prosthetic valve, elevated NT-proBNP levels are frequently observed despite preserved NYHA class. In PVR patients, a higher NT-proBNP level was associated with a lower VO2peak. These results may be of importance in the ongoing discussion about the timing of valve replacement in patients with CHD.
  相似文献   

13.

Background

Transcatheter aortic valve replacement (TAVR) has been demonstrated to be an established therapy for high-risk, inoperable patients with severe symptomatic aortic valve stenosis. For patients with moderate surgical risk, TAVR is equivalent to conventional aortic valve surgery. However, atrial fibrillation (AF) is also present in many of these patients, thus requiring post-implantation oral anticoagulation therapy in addition to the inhibition of thrombocyte aggregation, which poses the risk of bleeding complications. The aim of our work was to investigate the influence of AF on mortality and the occurrence of bleeding, vascular and cerebrovascular complications related to TAVR according to the VARC-2 criteria.

Methods

Two hundred eighty-three patients who underwent TAVR between March 2010 and April 2016 were retrospectively examined. In total, 257 patients who underwent transfemoral access were included in this study. The mean patient age was 81?±?6 years, 54.1% of the patients were women, and 42.4% had pre-interventional AF.

Results

Compared to patients with sinus rhythm (SR, n?=?148), patients with AF (n?=?109) had an almost three-fold higher incidence of major vascular complications (AF 14.7% vs. SR 5.4%, p?=?0.016) and life-threatening bleeding (AF 11.9% vs. SR 4.1%, p?=?0.028) during the first 30 post-procedural days. However, the rate of cerebrovascular complications (AF 3.7% vs. SR 2.7%, p?=?0.726) did not significantly differ between the two groups. Overall mortality was significantly higher in patients with AF during the first month (AF 8.3% vs. SR 2.0%, p?=?0.032) and the first year (AF 28.4% vs. SR 15.3%; p?=?0.020) following TAVR.

Conclusion

Patients with AF had significantly more severe bleeding complications after TAVR, which were significantly related to mortality. Future prospective randomized studies must clarify the optimal anticoagulation therapy for patients with AF after TAVR.

Trial registration

DRKS00011798 on DRKS (Date 17.03.2017).
  相似文献   

14.

Background

Tetralogy of Fallot (ToF) is the most common cyanotic congenital heart disease and the population of ToF repair survivors is growing rapidly. Adults with repaired ToF develop late complications. The aim of this study was to describe and analyze long-term follow-up of patients with repaired ToF.

Methods

This is a retrospective cohort study. Consecutive 83 patients with repaired ToF who did not undergo pulmonary valve replacement were included. Mean age of all patients was 30.5?±?10.7. There were 49 (59%) male. Patients were divided into two groups according to the time since the repair (<?25 years and?≥?25 years). The electrocardiographic (ECG), cardiopulmonary exercise testing (CPET), echocardiographic and cardiac magnetic resonance (CMR) data were reviewed retrospectively.

Results

In CPET values were not significantly different in the two groups. In CMR volumes of left and right ventricles were not significantly different in the two groups. There were no differences between the groups in ventricular ejection fraction, mass of ventricles, or pulmonary regurgitation fraction. Among all the patients, ejection fraction and left and right ventricle mass, indexed pulmonary regurgitation volume measured by CMR did not correlate with the time since repair. In ECG among all the patients, ejection fraction of the RV, measured in CMR, negatively correlated with QRS duration (r?=???0.43; p?<?0.001). There was a positive correlation between QRS duration and end diastolic volume of the RV (r?=?0.30; p?<?0.02), indexed end diastolic volume of the RV (r?=?0.29; p?=?0.04), RV mass (r?=?0.36; p?<?0.001) and left ventricle mass (r?=?0.26; p?=?0.04).

Conclusion

Long-term survival and clinical condition after surgical correction of ToF in infancy is generally good and the late functional status in ToF – operated patients could be excellent up to 25 years after the repair. QRS duration could be an utility and easy factor to assessment of right ventricular function.

Trial registration

The study protocol was approved by the local Ethics Committee. Each participant provided informed consent to participate in the study (license number 122.6120.88.2016 from 28.04.2016).
  相似文献   

15.

Introduction

Three-dimensional rotational angiography (3DRA) has been used in the guidance of various transcatheter therapies including percutaneous pulmonary valve implantation (PPVI). The most recently available 3D image fusion software (VesselNavigator, Philips) extends this technology to use pre-registered computed tomography or magnetic resonance imaging datasets, promising reductions in contrast and radiation exposure along with shorter procedural times.

Methods

In this retrospective review, patients were assigned to three groups according to the mode of imaging guidance: two-dimensional angiography (2DA), 3DRA and VesselNavigator (VN) assisted valve implantation. Patient characteristics and catheterisation data were reviewed with a focus on contrast and radiation exposure, fluoroscopy, and procedural times.

Results

Between July 2012 and June 2016, 21 patients underwent PPVI: 8 with 2D guidance, 6 patients with 3DRA and most recently 7 patients with VN assistance. Patents in the VN group received significantly less absolute and weight indexed contrast when compared with those with 2DA or 3DRA guided PPVI. Patients in the 2DA group received a significantly higher total dose area product radiation dose and air kerma in comparison with patients with 3DRA and VN guided intervention. Application of VN resulted in the shortest fluoroscopy time, although not statistically significant, and a significantly shorter study time when compared with 2DA.

Conclusions

Utilisation of pre-intervention image manipulation with VesselNavigator for 3D guidance of PPVI results in a reduction in contrast and radiation exposure and study time as compared with traditional 2D guidance, and contrast usage as compared with 3DRA.
  相似文献   

16.

Background

There are increasing evidence that left ventricle diastolic dysfunction is the initial functional alteration in the diabetic myocardium. In this study, we hypothesized that alogliptin prevents diastolic dysfunction and preserves left ventricular mitochondrial function and structure in diabetic rabbits.

Methods

A total of 30 rabbits were randomized into control group (CON, n?=?10), alloxan-induced diabetic group (DM, n?=?10) and alogliptin-treated (12.5 mg/kd/day for 12 weeks) diabetic group (DM-A, n?=?10). Echocardiographic and hemodynamic studies were performed in vivo. Mitochondrial morphology, respiratory function, membrane potential and reactive oxygen species (ROS) generation rate of left ventricular tissue were assessed. The serum concentrations of glucagon-like peptide-1, insulin, inflammatory and oxidative stress markers were measured. Protein expression of TGF-β1, NF-κB p65 and mitochondrial biogenesis related proteins were determined by Western blotting.

Results

DM rabbits exhibited left ventricular hypertrophy, left atrial dilation, increased E/e′ ratio and normal left ventricular ejection fraction. Elevated left ventricular end diastolic pressure combined with decreased maximal decreasing rate of left intraventricular pressure (??dp/dtmax) were observed. Alogliptin alleviated ventricular hypertrophy, interstitial fibrosis and diastolic dysfunction in diabetic rabbits. These changes were associated with decreased mitochondrial ROS production rate, prevented mitochondrial membrane depolarization and improved mitochondrial swelling. It also improved mitochondrial biogenesis by PGC-1α/NRF1/Tfam signaling pathway.

Conclusions

The DPP-4 inhibitor alogliptin prevents cardiac diastolic dysfunction by inhibiting ventricular remodeling, explicable by improved mitochondrial function and increased mitochondrial biogenesis.
  相似文献   

17.

Background

Pathogens identification is critical for the proper diagnosis and precise treatment of infective endocarditis (IE). Although blood and valve cultures are the gold standard for IE pathogens detection, many cases are culture-negative, especially in patients who had received long-term antibiotic treatment, and precise diagnosis has therefore become a major challenge in the clinic. Metagenomic sequencing can provide both information on the pathogenic strain and the antibiotic susceptibility profile of patient samples without culturing, offering a powerful method to deal with culture-negative cases.

Methods

To assess the feasibility of a metagenomic approach to detect the causative pathogens in resected valves from IE patients, we employed both next-generation sequencing and Oxford Nanopore Technologies MinION nanopore sequencing for pathogens and antimicrobial resistance detection in seven culture-negative IE patients. Using our in-house developed bioinformatics pipeline, we analyzed the sequencing results generated from both platforms for the direct identification of pathogens from the resected valves of seven clinically culture-negative IE patients according to the modified Duke criteria.

Results

Our results showed both metagenomics methods can be applied for the causative pathogen detection in all IE samples. Moreover, we were able to simultaneously characterize respective antimicrobial resistance features.

Conclusion

Metagenomic methods for IE detection can provide clinicians with valuable information to diagnose and treat IE patients after valve replacement surgery. However, more efforts should be made to optimize protocols for sample processing, sequencing and bioinformatics analysis.
  相似文献   

18.

Introduction

Collecting feces is easy. It offers direct outcome to endogenous and microbial metabolites.

Objectives

In a context of lack of consensus about fecal sample preparation, especially in animal species, we developed a robust protocol allowing untargeted LC-HRMS fingerprinting.

Methods

The conditions of extraction (quantity, preparation, solvents, dilutions) were investigated in bovine feces.

Results

A rapid and simple protocol involving feces extraction with methanol (1/3, M/V) followed by centrifugation and a step filtration (10 kDa) was developed.

Conclusion

The workflow generated repeatable and informative fingerprints for robust metabolome characterization.
  相似文献   

19.

Background

Behcet’s disease (BD) is a systemic vasculitis characterized by oral and genital aphthosis, and ocular and skin lesions. The disease is involved in vascular, gastrointestinal, and central nervous systems. Vasculitis may exacerbate fatal problems, such as anastomotic pseudoaneurysms. If the mesenteric vessels are involved, severe abdominal symptoms such as intestinal obstruction may occur.

Case presentation

This case report describes a young female patient who suffered from BD with recurrent abdominal aortic pseudoaneurysms, as well as deep venous thrombosis and subsequent complications of incomplete intestinal obstruction. This patient first underwent stent grafting, which was followed by rupture of two newly formed anastomotic pseudoaneurysms within six months. Emergency open surgical repair (OSR) was then performed on the ruptured pseudoaneurysms. Thrombosis and incomplete ileus occurred five months after surgery. This case was unique due to the presence of incomplete intestinal obstruction being the possible main complaint for a patient with Behcet’s disease, and it is the first ever case to be reported.

Conclusion

Intestinal obstruction may present as the possible main complaint in BD. Careful and attentive strategy should be carried out to prevent fatal outcomes.
  相似文献   

20.

Background

The rate of incidentally diagnosed congenital heart disease (CHD) in adulthood has not been reported. The aim of this study was to investigate the detection rate of CHD in adults by routine, general health checkups.

Methods

Data was acquired from 222,401 patients older than 19?years who participated in general health checkups from January 2010 to December 2016. We excluded persons who did not undergo echocardiography during the general health checkups, who underwent echocardiography prior to the health checkups, and who were previously diagnosed with CHD.

Results

Among the 27,897 patients, who were included in the final analysis, 293 cases were newly diagnosed as CHD, and the overall detection rate was 1.05%. The mean age of patients with CHD was 48.7?±?21.5?years, and most of them were female (n?=?187, 63.8%). More than two-thirds were between the third and fifth decade of life, and only six patients (2.04%) were older than 70?years. The most common type was bicuspid aortic valve (n?=?155). Interestingly, Ebstein’s anomaly that required surgical repair was detected in five persons.

Conclusions

During general health checkup, there were cases of severe CHD that required cardiac surgery upon diagnosis.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号