1.
BackgroundLittle is known about the diagnostic performance of rapid diagnostic tests (RDTs) for passive screening of human African trypanosomiasis (HAT) in Côte d’Ivoire. We determined HAT prevalence among clinical suspects, identified clinical symptoms and signs associated with HAT RDT positivity, and assessed the diagnostic tests’ specificity, positive predictive value and agreement.MethodsClinical suspects were screened with SD Bioline HAT, HAT Sero-K-Set and rHAT Sero-Strip. Seropositives were parasitologically examined, and their dried blood spots tested in trypanolysis, ELISA/Tbg, m18S-qPCR and LAMP. The HAT prevalence in the study population was calculated based on RDT positivity followed by parasitological confirmation. The association between clinical symptoms and signs and RDT positivity was determined using multivariable logistic regression. The tests’ Positive Predictive Value (PPV), specificity and agreement were determined.ResultsOver 29 months, 3433 clinical suspects were tested. The RDT positivity rate was 2.83%, HAT prevalence 0.06%. Individuals with sleep disturbances (p<0.001), motor disorders (p = 0.002), convulsions (p = 0.02), severe weight loss (p = 0.02) or psychiatric problems (p = 0.04) had an increased odds (odds ratios 1.7–4.6) of being HAT RDT seropositive. Specificities ranged between 97.8%-99.6% for individual RDTs, and 93.3–98.9% for subsequent tests on dried blood spots. The PPV of the individual RDTs was below 14.3% (CI 2–43), increased to 33.3% (CI 4–78) for serial RDT combinations, and reached 67% for LAMP and ELISA/Tbg on RDT positives. Agreement between diagnostic tests was poor to moderate (Kappa ≤ 0.60), except for LAMP and ELISA/Tbg (Kappa = 0.66).ConclusionIdentification of five key clinical symptoms and signs may simplify referral for HAT RDT screening. The results confirm the appropriateness of the diagnostic algorithm presently applied, with screening by SD Bioline HAT or HAT Sero-K-Set, supplemented with trypanolysis. ELISA/Tbg could replace trypanolysis and is simpler to perform.Trial registrationClinicalTrials.gov NCT03356665.  相似文献   

2.

Background

In endemic settings, diagnosis of malaria increasingly relies on the use of rapid diagnostic tests (RDTs). False positivity of such RDTs is poorly documented, although it is especially relevant in those infections that resemble malaria, such as human African trypanosomiasis (HAT). We therefore examined specificity of malaria RDT products among patients infected with Trypanosoma brucei gambiense.

Methodology/Principal Findings

Blood samples of 117 HAT patients and 117 matched non-HAT controls were prospectively collected in the Democratic Republic of the Congo. Reference malaria diagnosis was based on real-time PCR. Ten commonly used malaria RDT products were assessed including three two-band and seven three-band products, targeting HRP-2, Pf-pLDH and/or pan-pLDH antigens. Rheumatoid factor was determined in PCR negative subjects. Specificity of the 10 malaria RDT products varied between 79.5 and 100% in HAT-negative controls and between 11.3 and 98.8% in HAT patients. For seven RDT products, specificity was significantly lower in HAT patients compared to controls. False positive reactions in HAT were mainly observed for pan-pLDH test lines (specificities between 13.8 and 97.5%), but also occurred frequently for the HRP-2 test line (specificities between 67.9 and 98.8%). The Pf-pLDH test line was not affected by false-positive lines in HAT patients (specificities between 97.5 and 100%). False positivity was not associated to rheumatoid factor, detected in 7.6% of controls and 1.2% of HAT patients.

Conclusions/Significance

Specificity of some malaria RDT products in HAT was surprisingly low, and constitutes a risk for misdiagnosis of a fatal but treatable infection. Our results show the importance to assess RDT specificity in non-targeted infections when evaluating diagnostic tests.  相似文献   

3.

Background

Although malaria rapid diagnostic tests (RDT) are simple to perform, they remain subject to errors, mainly related to the post-analytical phase. We organized the first large scale SMS based external quality assessment (EQA) on correct reading and interpretation of photographs of a three-band malaria RDT among laboratory health workers in the Democratic Republic of the Congo (DR Congo).

Methods and Findings

High resolution EQA photographs of 10 RDT results together with a questionnaire were distributed to health facilities in 9 out of 11 provinces in DR Congo. Each laboratory health worker answered the EQA by Short Message Service (SMS). Filled-in questionnaires from each health facility were sent back to Kinshasa. A total of 1849 laboratory health workers in 1014 health facilities participated. Most frequent errors in RDT reading were i) failure to recognize invalid (13.2–32.5% ) or negative test results (9.8–12.8%), (ii) overlooking faint test lines (4.1–31.2%) and (iii) incorrect identification of the malaria species (12.1–17.4%). No uniform strategy for diagnosis of malaria at the health facility was present. Stock outs of RDTs occurred frequently. Half of the health facilities had not received an RDT training. Only two thirds used the RDT recommended by the National Malaria Control Program. Performance of RDT reading was positively associated with training and the technical level of health facility. Facilities with RDT positivity rates >50% and located in Eastern DR Congo performed worse.

Conclusions

Our study confirmed that errors in reading and interpretation of malaria RDTs are widespread and highlighted the problem of stock outs of RDTs. Adequate training of end-users in the application of malaria RDTs associated with regular EQAs is recommended.  相似文献   

4.

Background

Recent trends to earlier access to anti-retroviral treatment underline the importance of accurate HIV diagnosis. The WHO HIV testing strategy recommends the use of two or three rapid diagnostic tests (RDTs) combined in an algorithm and assume a population is serologically stable over time. Yet RDTs are prone to cross reactivity which can lead to false positive or discordant results. This paper uses discordancy data from Médecins Sans Frontières (MSF) programmes to test the hypothesis that the specificity of RDTs change over place and time.

Methods

Data was drawn from all MSF test centres in 2007-8 using a parallel testing algorithm. A Bayesian approach was used to derive estimates of disease prevalence, and of test sensitivity and specificity using the software WinBUGS. A comparison of models with different levels of complexity was performed to assess the evidence for changes in test characteristics by location and over time.

Results

106, 035 individuals were included from 51 centres in 10 countries using 7 different RDTs. Discordancy patterns were found to vary by location and time. Model fit statistics confirmed this, with improved fit to the data when test specificity and sensitivity were allowed to vary by centre and over time. Two examples show evidence of variation in specificity between different testing locations within a single country. Finally, within a single test centre, variation in specificity was seen over time with one test becoming more specific and the other less specific.

Conclusion

This analysis demonstrates the variable specificity of multiple HIV RDTs over geographic location and time. This variability suggests that cross reactivity is occurring and indicates a higher than previously appreciated risk of false positive HIV results using the current WHO testing guidelines. Given the significant consequences of false HIV diagnosis, we suggest that current testing and evaluation strategies be reviewed.  相似文献   

5.

Background

Although rapid diagnostic tests (RDTs) have practical advantages over light microscopy (LM) and good sensitivity in severe falciparum malaria in Africa, their utility where severe non-falciparum malaria occurs is unknown. LM, RDTs and polymerase chain reaction (PCR)-based methods have limitations, and thus conventional comparative malaria diagnostic studies employ imperfect gold standards. We assessed whether, using Bayesian latent class models (LCMs) which do not require a reference method, RDTs could safely direct initial anti-infective therapy in severe ill children from an area of hyperendemic transmission of both Plasmodium falciparum and P. vivax.

Methods and Findings

We studied 797 Papua New Guinean children hospitalized with well-characterized severe illness for whom LM, RDT and nested PCR (nPCR) results were available. For any severe malaria, the estimated prevalence was 47.5% with RDTs exhibiting similar sensitivity and negative predictive value (NPV) to nPCR (≥96.0%). LM was the least sensitive test (87.4%) and had the lowest NPV (89.7%), but had the highest specificity (99.1%) and positive predictive value (98.9%). For severe falciparum malaria (prevalence 42.9%), the findings were similar. For non-falciparum severe malaria (prevalence 6.9%), no test had the WHO-recommended sensitivity and specificity of >95% and >90%, respectively. RDTs were the least sensitive (69.6%) and had the lowest NPV (96.7%).

Conclusions

RDTs appear a valuable point-of-care test that is at least equivalent to LM in diagnosing severe falciparum malaria in this epidemiologic situation. None of the tests had the required sensitivity/specificity for severe non-falciparum malaria but the number of false-negative RDTs in this group was small.  相似文献   

6.

Background

In the Peruvian Amazon, Plasmodium falciparum and Plasmodium vivax malaria are endemic in rural areas, where microscopy is not available. Malaria rapid diagnostic tests (RDTs) provide quick and accurate diagnosis. However, pfhrp2 gene deletions may limit the use of histidine-rich protein-2 (PfHRP2) detecting RDTs. Further, cross-reactions of P. falciparum with P. vivax-specific test lines and vice versa may impair diagnostic specificity.

Methods

Thirteen RDT products were evaluated on 179 prospectively collected malaria positive samples. Species diagnosis was performed by microscopy and confirmed by PCR. Pfhrp2 gene deletions were assessed by PCR.

Results

Sensitivity for P. falciparum diagnosis was lower for PfHRP2 compared to P. falciparum-specific Plasmodium lactate dehydrogenase (Pf-pLDH)- detecting RDTs (71.6% vs. 98.7%, p<0.001). Most (19/21) false negative PfHRP2 results were associated with pfhrp2 gene deletions (25.7% of 74 P. falciparum samples). Diagnostic sensitivity for P. vivax (101 samples) was excellent, except for two products. In 10/12 P. vivax-detecting RDT products, cross-reactions with the PfHRP2 or Pf-pLDH line occurred at a median frequency of 2.5% (range 0%–10.9%) of P. vivax samples assessed. In two RDT products, two and one P. falciparum samples respectively cross-reacted with the Pv-pLDH line. Two Pf-pLDH/pan-pLDH-detecting RDTs showed excellent sensitivity with few (1.0%) cross-reactions but showed faint Pf-pLDH lines in 24.7% and 38.9% of P. falciparum samples.

Conclusion

PfHRP2-detecting RDTs are not suitable in the Peruvian Amazon due to pfhrp2 gene deletions. Two Pf-pLDH-detecting RDTs performed excellently and are promising RDTs for this region although faint test lines are of concern.  相似文献   

7.

Background

A major challenge in the control of human African trypanosomiasis (HAT) is lack of reliable diagnostic tests that are rapid and easy to use in remote areas where the disease occurs. In Trypanosoma brucei gambiense HAT, the Card Agglutination Test for Trypanosomiasis (CATT) has been the reference screening test since 1978, usually on whole blood, but also in a 1/8 dilution (CATT 1/8) to enhance specificity. However, the CATT is not available in a single format, requires a cold chain for storage, and uses equipment that requires electricity. A solution to these challenges has been provided by rapid diagnostic tests (RDT), which have recently become available. A prototype immunochromatographic test, the SD BIOLINE HAT, based on two native trypanosomal antigens (VSG LiTat 1.3 and VSG LiTat 1.5) has been developed. We carried out a non-inferiority study comparing this prototype to the CATT 1/8 in field settings.

Methodology/Principal Findings

The prototype SD BIOLINE HAT, the CATT Whole Blood and CATT 1/8 were systematically applied on fresh blood samples obtained from 14,818 subjects, who were prospectively enrolled through active and passive screening in clinical studies in three endemic countries of central Africa: Angola, the Democratic Republic of the Congo and the Central African Republic. One hundred and forty nine HAT cases were confirmed by parasitology. The sensitivity and specificity of the prototype SD BIOLINE HAT was 89.26% (95% confidence interval (CI) = 83.27–93.28) and 94.58% (95% CI = 94.20–94.94) respectively. The sensitivity and specificity of the CATT on whole blood were 93.96% (95% CI = 88.92–96.79) and 95.91% (95% CI = 95.58–96.22), and of the CATT 1/8 were 89.26% (95% CI = 83.27–93.28) and 98.88% (95% CI = 98.70–99.04) respectively.

Conclusion/Significance

After further optimization, the prototype SD BIOLINE HAT could become an alternative to current screening methods in primary healthcare settings in remote, resource-limited regions where HAT typically occurs.  相似文献   

8.

Background

In the absence of well-equipped laboratory infrastructure in many developing countries the accurate diagnosis of typhoid fever is challenging. Rapid diagnostic tests (RDT) with good performance indicators would be helpful to improve clinical management of suspected cases. We performed a systematic literature review and meta- analysis to determine the performance of TUBEX TF and Typhidot for the diagnosis of typhoid fever using PRISMA guidelines.

Methods

Titles and abstracts were reviewed for relevance. Articles were screened for language, reference method and completeness. Studies were categorized according to control groups used. Meta-analysis was performed only for categories where enough data was available to combine sensitivity and specificity estimates. Sub-analysis was performed for the Typhidot test to determine the influence of indeterminate results on test performance.

Results

A total of seven studies per test were included. The sensitivity of TUBEX TF ranged between 56% and 95%, Specificity between 72% and 95%. Meta-analysis showed an average sensitivity of 69% (95%CI: 45–85) and an average specificity of 88% (CI95%:83–91). A formal meta-analysis for Typhidot was not possible due to limited data available. Across the extracted studies, sensitivity and specificity estimates ranged from 56% to 84% and 31% to 97% respectively.

Conclusion

The observed performance does not support the use of either rapid diagnostic test exclusively as the basis for diagnosis and treatment. There is a need to develop an RDT for typhoid fever that has a performance level comparable to malaria RDTs.  相似文献   

9.

Background

Malaria presents a diagnostic challenge in areas where both Plasmodium falciparum and P.vivax are co-endemic. Bivalent Rapid Diagnostic tests (RDTs) showed promise as diagnostic tools for P.falciparum and P.vivax. To assist national malaria control programme in the selection of RDTs, commercially available seven malaria RDTs were evaluated in terms of their performance with special reference to heat stability.

Methodology/Principal Findings

This study was undertaken in four forested districts of central India (July, 2011– March, 2012). All RDTs were tested simultaneously in field along with microscopy as gold standard. These RDTs were stored in their original packing at 25°C before transport to the field or they were stored at 35°C and 45°C upto 100 days for testing the performance of RDTs at high temperature. In all 2841 patients with fever were screened for malaria of which 26% were positive for P.falciparum, and 17% for P.vivax. The highest sensitivity of any RDT for P.falciparum was 98% (95% CI; 95.9–98.8) and lowest sensitivity was 76% (95% CI; 71.7–79.6). For P.vivax highest and lowest sensitivity for any RDT was 80% (95% CI; 94.9 - 83.9) and 20% (95% CI; 15.6–24.5) respectively. Heat stability experiments showed that most RDTs for P.falciparum showed high sensitivity at 45°C upto 90 days. While for P.vivax only two RDTs maintained good sensitivity upto day 90 when compared with RDTs kept at room temperature. Agreement between observers was excellent for positive and negative readings for both P.falciparum and P.vivax (Kappa >0.6–0.9).

Conclusion

This is first field evaluation of RDTs regarding their temperature stability. Although RDTs are useful as diagnostic tool for P.falciparum and P.vivax even at high temperature, the quality of RDTs should be regulated and monitored more closely.  相似文献   

10.

Purpose

To conduct a meta-analysis to evaluate the diagnostic value of anti-muscarinic receptor type 3 (M3R) antibodies in Sjögren syndrome (SS).

Methods

Two databases, PUBMED and the Cochrane Library, were systematically searched. Approximately 2,000 participants from several studies were included in this research. STATA 11.2 software and Meta-DiSc 1.4 was used to conduct the meta-analysis.

Results

Eleven studies were included in the meta-analysis. The pooled DOR was 13.00 (95% CI, 6.00–26.00). The sensitivity was 0.43 (95% CI, 0.28–0.58) and the specificity was 0.95 (95%CI, 0.91–0.97). The LR+ and LR- were 7.90 (95% CI, 4.70–13.40), 0.61 (95% CI, 0.46–0.79), respectively. The AUC was 0.89 (95% CI, 0.86–0.92).

Conclusion

The anti-M3R antibody had high specificity but relatively low sensitivity for the diagnosis of SS.  相似文献   

11.

Background

Laboratory capacity to confirm malaria cases in Tanzania is low and presumptive treatment of malaria is being practiced widely. In malaria endemic areas WHO now recommends systematic laboratory testing when suspecting malaria. Currently, the use of Rapid Diagnostic Tests (RDTs) is recommended for the diagnosis of malaria in lower level peripheral facilities, but not in health centres and hospitals. In this study, the following parameters were evaluated: (1) the quality of routine microscopy, and (2) the effects of RDT implementation on the positivity rate of malaria test results at three levels of the health system in Dar es Salaam, Tanzania.

Methods

During a baseline cross-sectional survey, routine blood slides were randomly picked from 12 urban public health facilities in Dar es Salaam, Tanzania. Sensitivity and specificity of routine slides were assessed against expert microscopy. In March 2007, following training of health workers, RDTs were introduced in nine public health facilities (three hospitals, three health centres and three dispensaries) in a near-to-programmatic way, while three control health facilities continued using microscopy. The monthly malaria positivity rates (PR) recorded in health statistics registers were collected before (routine microscopy) and after (routine RDTs) the intervention in all facilities.

Results

At baseline, 53% of blood slides were reported as positive by the routine laboratories, whereas only 2% were positive by expert microscopy. Sensitivity of routine microscopy was 71.4% and specificity was 47.3%. Positive and negative predictive values were 2.8% and 98.7%, respectively. Median parasitaemia was only three parasites per 200 white blood cells (WBC) by routine microscopy compared to 1226 parasites per 200 WBC by expert microscopy. Before RDT implementation, the mean test positivity rates using routine microscopy were 43% in hospitals, 62% in health centres and 58% in dispensaries. After RDT implementation, mean positivity rates using routine RDTs were 6%, 7% and 8%, respectively. The sensitivity and specificity of RDTs using expert microscopy as reference were 97.0% and 96.8%. The positivity rate of routine microscopy remained the same in the three control facilities: 71% before versus 72% after. Two cross-sectional health facility surveys confirmed that the parasite rate in febrile patients was low in Dar es Salaam during both the rainy season (13.6%) and the dry season (3.3%).

Conclusions

The quality of routine microscopy was poor in all health facilities, regardless of their level. Over-diagnosis was massive, with many false positive results reported as very low parasitaemia (1 to 5 parasites per 200 WBC). RDTs should replace microscopy as first-line diagnostic tool for malaria in all settings, especially in hospitals where the potential for saving lives is greatest.
  相似文献   

12.

Background

School surveys provide an operational approach to assess malaria transmission through parasite prevalence. There is limited evidence on the comparability of prevalence estimates obtained from school and community surveys carried out at the same locality.

Methods

Concurrent school and community cross-sectional surveys were conducted in 46 school/community clusters in the western Kenyan highlands and households of school children were geolocated. Malaria was assessed by rapid diagnostic test (RDT) and combined seroprevalence of antibodies to bloodstage Plasmodium falciparum antigens.

Results

RDT prevalence in school and community populations was 25.7% (95% CI: 24.4-26.8) and 15.5% (95% CI: 14.4-16.7), respectively. Seroprevalence in the school and community populations was 51.9% (95% CI: 50.5-53.3) and 51.5% (95% CI: 49.5-52.9), respectively. RDT prevalence in schools could differentiate between low (<7%, 95% CI: 0-19%) and high (>39%, 95% CI: 25-49%) transmission areas in the community and, after a simple adjustment, were concordant with the community estimates.

Conclusions

Estimates of malaria prevalence from school surveys were consistently higher than those from community surveys and were strongly correlated. School-based estimates can be used as a reliable indicator of malaria transmission intensity in the wider community and may provide a basis for identifying priority areas for malaria control.  相似文献   

13.

Background

User-friendly, accurate, point-of-care rapid tests to detect glucose-6-phosphate dehydrogenase deficiency (G6PDd) are urgently needed at peripheral level to safely recommend primaquine for malaria elimination.

Methods

The CareStart G6PD RDT (AccessBio, New Jersey, USA), a novel rapid diagnostic test and the most commonly used test, the fluorescent spot test (FST) were assessed against the quantitatively measured G6PD enzyme activity for detecting G6PDd. Subjects were healthy males and non-pregnant females aged 18 years or older residing in six villages in Pailin Province, western Cambodia.

Findings

Of the 938 subjects recruited, 74 (7.9%) were severe and moderately severe G6PD deficient (enzyme activity <30%), mostly in male population; population median G6PD activity was 12.0 UI/g Hb. The performances of the CareStart G6PD RDT and the FST, according to different cut-off values used to define G6PDd were very similar. For the detection of severe and moderately severe G6PDd (enzyme activity <30%, <3.6 UI/g Hb) in males and females, sensitivity and negative (normal status) predictive value were 100% for both point-of-care tools. When the G6PDd cut-off value increased (from <40% to <60%), the sensitivity for both PoCs decreased: 93.3% to 71.7% (CareStart G6PD RDT, p = 10−6) and 95.5% to 73.2% (FST, p = 10−6) while the specificity for both PoCs remained similar: 97.4% to 98.3% (CareStart G6PD RDT, p = 0.23) and 98.7% to 99.6% (FST, p = 0.06). The cut-off values for classifying individuals as normal were 4.0 UI/g Hb and 4.3 UI/g Hb for the CareStart G6PD RDT and the FST, respectively.

Conclusions

The CareStart G6PD RDT reliably detected moderate and severe G6PD deficient individuals (enzyme activity <30%), suggesting that this novel point-of-care is a promising tool for tailoring appropriate primaquine treatment for malaria elimination by excluding individuals with severe G6PDd for primaquine treatment.  相似文献   

14.
BackgroundDiagnosis of human African trypanosomiasis (HAT) remains a challenge both for active screening, which is critical in control of the disease, and in the point-of-care scenario where early and accurate diagnosis is essential. Recently, the first field deployment of a lateral flow rapid diagnostic test (RDT) for HAT, “SD BIOLINE HAT” has taken place. In this study, we evaluated the performance of “SD BIOLINE HAT” and two new prototype RDTs.Conclusions/SignificanceBoth “SD BIOLINE HAT” and the prototype devices performed comparably well to one another and also to the published performance range of the card agglutination test for trypanosomiasis in sensitivity and specificity. The performance of individual antigens enabled us to predict that an all-recombinant antigen RDT can be developed with an accuracy equivalent to “ SD BIOLINE HAT.” Such an RDT would have advantages in simplified manufacture, lower unit cost and assured reproducibility.  相似文献   

15.

Background

Despite the benefits of malaria diagnosis, most presumed malaria episodes are never tested. A primary reason is the absence of diagnostic tests in retail establishments, where many patients seek care. Malaria rapid diagnostic tests (RDTs) in drug shops hold promise for guiding appropriate treatment. However, retail providers generally lack awareness of RDTs and training to administer them. Further, unsubsidized RDTs may be unaffordable to patients and unattractive to retailers. This paper reports results from an intervention study testing the feasibility of RDT distribution in Ugandan drug shops.

Methods and Findings

92 drug shops in 58 villages were offered subsidized RDTs for sale after completing training. Data on RDT purchases, storage, administration and disposal were collected, and samples were sent for quality testing. Household surveys were conducted to capture treatment outcomes. Estimated daily RDT sales varied substantially across shops, from zero to 8.46 RDTs per days. Overall compliance with storage, treatment and disposal guidelines was excellent. All RDTs (100%) collected from shops passed quality testing. The median price charged for RDTs was 1000USH ($0.40), corresponding to a 100% markup, and the same price as blood slides in local health clinics. RDTs affected treatment decisions. RDT-positive patients were 23 percentage points more likely to buy Artemisinin Combination Therapies (ACTs) (p = .005) and 33.1 percentage points more likely to buy other antimalarials (p<.001) than RDT-negative patients, and were 5.6 percentage points more likely to buy ACTs (p = .05) and 31.4 percentage points more likely to buy other antimalarials (p<.001) than those not tested at all.

Conclusions

Despite some heterogeneity, shops demonstrated a desire to stock RDTs and use them to guide treatment recommendations. Most shops stored, administered and disposed of RDTs properly and charged mark-ups similar to those charged on common medicines. Results from this study suggest that distributing RDTs through the retail sector is feasible and can reduce inappropriate treatment for suspected malaria.  相似文献   

16.

Background

Early diagnosis of dengue virus (DENV) infection can improve clinical outcomes by ensuring close follow-up, initiating appropriate supportive therapies and raising awareness to the potential of hemorrhage or shock. Non-structural glycoprotein-1 (NS1) has proven to be a useful biomarker for early diagnosis of dengue. A number of rapid diagnostic tests (RDTs) and enzyme-linked immunosorbent assays (ELISAs) targeting NS1 antigen (Ag) are now commercially available. Here we evaluated these tests using a well-characterized panel of clinical samples to determine their effectiveness for early diagnosis.

Methodology/Principal Findings

Retrospective samples from South America were used to evaluate the following tests: (i) “Dengue NS1 Ag STRIP” and (ii) “Platelia Dengue NS1 Ag ELISA” (Bio-Rad, France), (iii) “Dengue NS1 Detect Rapid Test (1st Generation)” and (iv) “DENV Detect NS1 ELISA” (InBios International, United States), (v) “Panbio Dengue Early Rapid (1st generation)” (vi) “Panbio Dengue Early ELISA (2nd generation)” and (vii) “SD Bioline Dengue NS1 Ag Rapid Test” (Alere, United States). Overall, the sensitivity of the RDTs ranged from 71.9%–79.1% while the sensitivity of the ELISAs varied between 85.6–95.9%, using virus isolation as the reference method. Most tests had lower sensitivity for DENV-4 relative to the other three serotypes, were less sensitive in detecting secondary infections, and appeared to be most sensitive on Day 3–4 post symptom onset. The specificity of all evaluated tests ranged from 95%–100%.

Conclusions

ELISAs had greater overall sensitivity than RDTs. In conjunction with other parameters, the performance data can help determine which dengue diagnostics should be used during the first few days of illness, when the patients are most likely to present to a clinic seeking care.  相似文献   

17.
BackgroundCholera, an acute diarrheal disease is a major public health problem in many developing countries. Several rapid diagnostic tests (RDT) are available for the detection of cholera, but their efficacies are not compared in an endemic setting. In this study, we have compared the specificity and sensitivity of three RDT kits for the detection of Vibrio cholerae O1 and compared their efficiency with culture and polymerase chain reaction (PCR) methods.MethodsFive hundred six diarrheal stool samples collected from patients from two different hospitals in Kolkata, India were tested using SD Bioline Cholera, SMART-II Cholera O1 and Crystal-VC RDT kits. All the stool samples were screened for the presence of V. cholerae by direct and enrichment culture methods. Stool DNA-based PCR assay was made to target the cholera toxin (ctxAB) and O1 somatic antigen (rfb) encoding genes. Statistical evaluation of the RDTs has been made using STATA software with stool culture and PCR results as the gold standards. The Bayesian latent class model (LCM) was used to evaluate the diagnostic tests in the absence of the gold standard.ResultsInvolving culture technique as gold standard, the sensitivity and specificity of the cholera RDT kits in the direct testing of stools was highest with SAMRT-II (86.1%) and SD-Cholera (94.4%), respectively. The DNA based PCR assays gave very high sensitivity (98.4%) but the specificity was comparatively low (75.3%). After enrichment, the high sensitivity and specificity was detected with SAMRT-II (78.8%) and SD-Cholera (99.1%), respectively. Considering PCR as the gold standard, the sensitivity and specificity of the RDTs remained between 52.3–58.2% and 92.3–96.8%, respectively. In the LCM, the sensitivity of direct and enrichment testing was high in SAMRT-II (88% and 92%, respectively), but the specificity was high in SD cholera for both the methods (97% and 100%, respectively). The sensitivity/specificity of RDTs and direct culture have also been analyzed considering the age, gender and diarrheal disease severity of the patients.ConclusionOverall, the performance of the RDT kits remained almost similar in terms of specificity and sensitivity. Performance of PCR was superior to the antibody-based RDTs. The RTDs are very useful in identifying cholera cases during outbreak/epidemic situations and for making them as a point-of-care (POC) testing tool needs more improvement.  相似文献   

18.

Background

Rapid and point-of-care (POC) tests for syphilis are an invaluable screening tool, yet inadequate evaluation of their diagnostic accuracy against best reference standards limits their widespread global uptake. To fill this gap, a systematic review and meta-analysis was conducted to evaluate the sensitivity and specificity of rapid and POC tests in blood and serum samples against Treponema pallidum (TP) specific reference standards.

Methods

Five electronic databases (1980–2012) were searched, data was extracted from 33 articles, and Bayesian hierarchical models were fit.

Results

In serum samples, against a TP specific reference standard point estimates with 95% credible intervals (CrI) for the sensitivities of popular tests were: i) Determine, 90.04% (80.45, 95.21), ii) SD Bioline, 87.06% (75.67, 94.50), iii) VisiTect, 85.13% (72.83, 92.57), and iv) Syphicheck, 74.48% (56.85, 88.44), while specificities were: i) Syphicheck, 99.14% (96.37, 100), ii) Visitect, 96.45% (91.92, 99.29), iii) SD Bioline, 95.85% (89.89, 99.53), and iv) Determine, 94.15% (89.26, 97.66). In whole blood samples, sensitivities were: i) Determine, 86.32% (77.26, 91.70), ii) SD Bioline, 84.50% (78.81, 92.61), iii) Syphicheck, 74.47% (63.94, 82.13), and iv) VisiTect, 74.26% (53.62, 83.68), while specificities were: i) Syphicheck, 99.58% (98.91, 99.96), ii) VisiTect, 99.43% (98.22, 99.98), iii) SD Bioline, 97.95%(92.54, 99.33), and iv) Determine, 95.85% (92.42, 97.74).

Conclusions

Rapid and POC treponemal tests reported sensitivity and specificity estimates comparable to laboratory-based treponemal tests. In resource limited settings, where access to screening is limited and where risk of patients lost to follow up is high, the introduction of these tests has already been shown to improve access to screening and treatment to prevent stillbirths and neonatal mortality due to congenital syphilis. Based on the evidence, it is concluded that rapid and POC tests are useful in resource limited settings with poor access to laboratories or screening for syphilis.  相似文献   

19.

Background

Diagnosis of leptospirosis by the microscopic agglutination test (MAT) or by culture is confined to specialized laboratories. Although ELISA techniques are more common, they still require laboratory facilities. Rapid Diagnostic Tests (RDTs) can be used for easy point-of-care diagnosis. This study aims to evaluate the diagnostic performance of the RDTs LeptoTek Dri Dot, LeptoTek Lateral Flow, and Leptocheck-WB, prospectively.

Methodology

During 2001 to 2012, one or two of the RDTs at the same time have been applied prior to routine diagnostics (MAT, ELISA and culture) on serum specimens from participants sent in for leptospirosis diagnosis. The case definition was based on MAT, ELISA and culture results. Participants not fulfilling the case definition were considered not to have leptospirosis. The diagnostic accuracy was determined based on the 1st submitted sample and paired samples, either in an overall analysis or stratified according to days post onset of illness.

Results

The overall sensitivity and specificity for the LeptoTek Dri Dot was 75% respectively 96%, for the LeptoTek Lateral Flow 78% respectively 95%, and for the Leptocheck-WB 78% respectively 98%. Based on the 1st submitted sample the sensitivity was low (51% for LeptoTek Dri Dot, 69% for LeptoTek Lateral Flow, and 55% for Leptocheck-WB), but substantially increased when the results of paired samples were combined, although accompanied by a lower specificity (82% respectively 91% for LeptoTek Dri Dot, 86% respectively 84% for LeptoTek Lateral Flow, and 80% respectively 93% for Leptocheck-WB).

Conclusions

All three tests present antibody tests contributing to the diagnosis of leptospirosis, thus supporting clinical suspicion and contributing to awareness. Since the overall sensitivity of the tested RDTs did not exceed 80%, one should be cautious to rely only on an RDT result, and confirmation by reference tests is strongly recommended.  相似文献   

20.

Background

The polymerase chain reaction (PCR) and nucleic acid sequence-based amplification (NASBA) have been recently modified by coupling to oligochromatography (OC) for easy and fast visualisation of products. In this study we evaluate the sensitivity and specificity of the PCR-OC and NASBA-OC for diagnosis of Trypanosoma brucei gambiense and Trypanosoma brucei rhodesiense human African trypanosomiasis (HAT).

Methodology and Results

Both tests were evaluated in a case-control design on 143 HAT patients and 187 endemic controls from the Democratic Republic of Congo (DRC) and Uganda. The overall sensitivity of PCR-OC was 81.8% and the specificity was 96.8%. The PCR-OC showed a sensitivity and specificity of 82.4% and 99.2% on the specimens from DRC and 81.3% and 92.3% on those from Uganda. NASBA-OC yielded an overall sensitivity of 90.2%, and a specificity of 98.9%. The sensitivity and specificity of NASBA-OC on the specimens from DRC was 97.1% and 99.2%, respectively. On the specimens from Uganda we observed a sensitivity of 84.0% and a specificity of 98.5%.

Conclusions/Significance

The tests showed good sensitivity and specificity for the T. b. gambiense HAT in DRC but rather a low sensitivity for T. b. rhodesiense HAT in Uganda.  相似文献   