首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
动物实验中,计算小动物呼吸容量如潮气量时通常遵循Boyle定律。而小动物在压力型体积描记箱内呼吸时,箱内气体处于不停的流动状态。为了研究气体流动本身对描记箱内压力是否产生影响,本研究采用空气动力学理论推导出压力型体积描记箱内压力变化的近似公式,并设计了三个实验对理论公式进行证明。首先,往体积描记箱内注入0.1mL、0.2mL和0.4mL空气,结果显示,描记箱内压力迅速上升至一峰值然后下降为一水平的基线压力值。3种容量的空气注入产生的压力变化最大值(峰压)及压力保持平稳时的压力变化值(基线压)分别为:(0.828±0.004)cmH2O、(0.684±0.003)cmH2O;(1.650±0.010)cmH2O、(1.350±0.007)cmH2O;(3.280±0.014)cmH2O、(2.658±0.011)cmH2O,峰压均显著高于基线压。其次,往体积描记箱内注入相同容量、但通气频率不同的空气,结果显示,随着注入空气的频率增加,描记箱内压力变化幅度亦显著增加。最后,用小动物呼吸机和微量移液器分别往描记箱内注入相同容量、相同频率但流量-时间函数不同的气体,结果显示,呼吸机引起的体积描记箱内峰压及基线压均显著高于微量移液器。以上结果表明,空气流动本身在压力型体积描记箱内引起压力变化;空气流动越快,压力变化幅度也越大;流动空气的流量是时间的不同函数时,压力变化也将显著不同。因此要精确地计算小动物呼吸容量变化,需要使用更多的空气动力学原理。  相似文献   

2.
We have tested a new fiber-optic pressure recording system, Samba, with a thin fiber [outer diameter (OD) = 0.25 mm] and a pressure sensor (length and OD = 0.42 mm) attached to the end. The accuracy of the system tested in vitro was good, with a coefficient of variation of 2.54% at 100 mmHg. The drift was <0.45 mmHg/h, and the temperature sensitivity was approximately 0.07 mmHg/1 degrees C between 22 and 37 degrees C. The frequency response characteristics were similar to a 1.4-Fr Millar catheter (0-200 Hz). Introduction of the Samba sensor from the right carotid artery into the left ventricle in six mice caused no drop in mean aortic pressure, whereas introduction of a 1.4-Fr Millar catheter (OD = 0.47 mm; n = 6) caused a pressure drop from 91.6 +/- 9.2 to 65.1 +/- 6.2 mmHg; P < 0.05. Thus the Samba sensor system may represent a new alternative to assess hemodynamic variables in the murine cardiovascular system.  相似文献   

3.
The Laks catheter is a triple-lumen balloon catheter used to distend the canine main pulmonary artery while recording right ventricular pressure and the arterial pressure distal to the balloon. A rise in arterial pressure reported to occur during distension has been attributed to vasoconstriction rather than passive obstruction by the balloon. We tested this in six anesthetized dogs by inflating the Laks catheter-balloon while recording pressure distal to the balloon from the Laks catheter as well as from additional catheters in right and left pulmonary arteries placed retrogradely through lobar branches following thoracotomy. We found that balloon inflation increased pressures in the arterial port of the Laks catheter and in the left pulmonary artery catheter but reduced it in the right pulmonary artery. Tightening a snare around the right pulmonary artery had the same effects on pressures. Similar results were obtained while cardiac output was controlled by left ventricular bypass perfusion in four dogs. We conclude that the Laks catheter-balloon obstructs flow to the right lung and that the arterial pressure rise recorded in it during balloon inflation cannot be distinguished from that caused by occlusion of the right pulmonary artery.  相似文献   

4.
In 15 anesthetized apneic, oxygenated rabbits we simultaneously measured pleural liquid and interstitial extrapleural parietal pressures by using catheters and/or cannulas and micropipettes connected to a servonull system. With the animal in lateral posture, at an average recording height of 4.4 +/- 0.9 (SD) cm from the most dependent part of the cavity, the extrapleural catheter and the pleural cannula yielded -2.5 +/- 0.6 and -5.5 +/- 0.2 cmH2O; the corresponding values for micropipette readings in the two compartments were -2.4 +/- 0.6 and -5.4 +/- 0.4 cmH2O, respectively (not significantly different from those measured with catheters and cannulas). In the supine animal, interstitial extrapleural catheter pressure data obtained at recording heights ranging from 15 to 80% of pleural cavity lay on the identity line when plotted vs. the micropipette pressure values simultaneously gathered from the same tissues. We conclude that 1) micropipettes and catheters-cannulas yield similar results when recording from the same compartment and 2) the hydraulic pressure in the parietal extrapleural interstitium is less negative than that in the pleural space.  相似文献   

5.
After describing the site of fertilisation and that of the functional sperm reservoir in the female tract, proposals are made concerning a modified site of sperm deposition in cattle. By means of a deep pre-ovulatory insemination into the ipsilateral uterine horn, the chances should be raised of establishing viable spermatozoa in the isthmus where they would undergo a form of physiological encapsulation and storage. Release and activation of such spermatozoa would be prompted by imminent ovulation. Potential advantages of this approach include those of raising the overall fertility of genetically valuable bulls whose non-return rates are sub-optimal; reducing the number of spermatozoa in each insemination dose; using effectively the limited numbers of sex-selected sperm cells (X and Y chromosome bearing spermatozoa) currently available from flow cytometry. Putative disadvantages might include rectal palpation of the ovaries to locate the pre-ovulatory follicle; perforation of the uterine wall by the deep insemination catheter; risk of Polyspermie fertilisation; and the inappropriateness of the technique for non-clinically qualified inseminators. Each of these reservations is responded to in a rational manner. Given a change of attitude, a modified technique of insemination would be feasible under commercial conditions and might give a welcome boost to a sagging artificial insemination industry. kw|Keywords|k]uterus; k]cow; k]fertilisation; k]sperm reservoir; k]Fallopian tube; k]isthmus; k]polyspermy; k]glycoproteins  相似文献   

6.
The dynamic pressure method (DPM) is used for measurement of k(L)a in a 1-m(3) pilot scale fermentor in coalescing (distilled water) and noncoalescing (0.3 M Na(2)SO(4) aqueous solution) batches. The method consists in recording oxygen concentration in a batch after a small pressure change (20 kPa) in the fermentor. The upward pressure change is brought about by temporary closing and subsequent throttling of outlet gas stream and the downward change by full reopening of the gas outlet. Absorption of pure oxygen yields the same k(L)a values as absorption of air. In noncoalescing batch, the downward k(L)a values are always higher than the upward values owing to spontaneous nucleation of bubbles. The experiments performed in a stirred cell confirm this behavior. Thus, only upward pressure change should be used for measurement. The correlation of k(L)a data measured in small (18-L) and large (1000-L) vessels based on power dissipated and superficial gas velocity are in a good agreement. Unlike the DPM, the classical dynamic methods yield, under the same conditions, excessively low values of k(L)a (the dynamic startup method) or fail to produce data at all (the dynamic method with interchange of air for N(2)). (c) 1994 John Wiley & Sons, Inc.  相似文献   

7.
Sandin  A.  Girma  K.  Sjöholm  B.  Lindholm  A.  Nilsson  G. 《Acta veterinaria Scandinavica》1998,39(2):265-272
Plasma gastrin concentrations were determined in 6 Standardbreds (4 geldings and 2 mares) after 3 different meals consisting of unlimited amounts of hay (8-9 kg per horse), a restricted amount of hay (0.6 kg/100 kg body-weight) and grain (0.2 kg/100 kg body-weight) in combination or of grain alone (0.2 kg/100 kg body-weight). In another series of experiments the possible role of gastrin as a stress hormone was investigated. Plasma gastrin and Cortisol concentrations were determined during fasting and compared with concentrations during hay feeding. In addition, gastrin and Cortisol concentrations were determined before, during and after 2 kinds of physical exercise on a treadmill. Meal stimulation significantly increased the plasma gastrin concentration, irrespective of the meal composition. An immediate and large increase in plasma gastrin concentration was found when voluminous meals were given, whereas a small meal evoked a later onset of gastrin release, suggesting that gastric distention plays an important role in inducing gastrin release during a meal. Meals consisting of grain seem to evoke a slower onset and then a more prolonged gastrin response than a hay meal, possibly due to different emptying rates of the stomach. Nervous excitation may play a minor role in the activation of gastrin release in horses. No experimental support was obtained for the idea that gastrin acts as a stress hormone in the horse. kw|Keywords|k]Cortisol; k]exercise; k]feeding; k]fasting  相似文献   

8.
目的建立一种滴注剂量精确的大鼠无创气管滴注方法。方法选用一次性使用静脉输液针的胶管制作套管,透射光插管法行大鼠气管插管,微量进样器平头针经由套管插入气管进行滴注。滴注液体为生理盐水,滴注剂量5~200μL,精确度为1μL。结果在体重200—350g的10只大鼠上共完成50次气管滴注操作,实验过程中和实验之后大鼠均无异常表现。结论套管微量进样器法具有无创、精确、安全的特点,可广泛应用于大鼠经气管给药或染毒的各类研究。  相似文献   

9.
An investigation was conducted to assess the accuracy of left heart filling pressures determined by a right heart catheter introduced at the bedside. Twelve patients were studied after open cardiac surgery by simultaneously recording pressures from both sides of the pulmonary capillary bed with a direct left atrial catheter and a flow-directed pulmonary arterial catheter. The mean pulmonary artery “occluded” pressure was shown to be a highly reliable index of mean left atrial pressure in all cases. It was much more accurate than pulmonary end-diastolic pressure, especially in six patients with pre-existing pulmonary hypertension.  相似文献   

10.
Pleural pressure is usually estimated with a balloon catheter (BC) positioned in the middle third of the esophagus. An alternate method, which avoids potential inaccuracies associated with changes in balloon volume, is a catheter-mounted transducer (CMT) system. To assess the accuracy of a CMT system in defining the elastic properties of the lungs, we compared the static pressure-volume (PV) properties of the lungs measured sequentially with CMT and BC systems in six healthy subjects each on two occasions, relating static transpulmonary pressure (Pst,L) to lung volume during interrupted exhalations from total lung capacity (TLC). PV data were fitted with an exponential function (least-squares method), and the exponent (k) was used to define the shape of the PV curve; position was defined by Pst,L at TLC and at 90 and 60% TLC. These data were examined for agreement (paired t test) and repeatability (coefficient of repeatability). No significant differences were demonstrated: k was 0.10 +/- 0.02 and 0.11 +/- 0.03 (SD) and Pst,L at 60% TLC was 8.27 +/- 2.09 and 8.37 +/- 1.63 cmH2O for the CMT and BC systems, respectively. The coefficient of repeatability for each parameter was not significantly different but was consistently less with the BC, suggesting better repeatability. We conclude that a CMT system is an acceptable alternative to a BC system for defining the elastic properties of lungs.  相似文献   

11.
A comparison was made between different anaesthetics for general anaesthesia in growing pigs, with focus on minor surgery under field conditions and for experiments in clinical research. Healthy crossbreed pigs (HampshirexYorkshirexSwedish Landrace) weighing 20–45 kg were used. The anaesthetics combinations compared were 1) azaperone plus metomidate (AM), 2) Zoletil® (zolazepam + tiletamine) plus xylazine (ZX), and 3) Zoletil® plus xylazine plus ketamine (ZXK). Parameters measured were: heart rate, respiratory rate, blood pressure, body temperature, and depth of analgesia (pin-prick). Minor surgery was performed to test the reliability of the “pin-prick” tests. It was clearly shown that AM produces anaesthesia with good cardiovascular stability and is a drug combination that is suitable for minor surgery. ZX also produces a good anaesthesia characterized by reliable and rapid induction. Good cardiovascular function is maintained, and the laryngeal relaxation makes intubation possible. These characteristics are very useful in a laboratory environment, as easy handling to avoid stress is necessary for research. Although it is difficult to evaluate the quality of analgesia from this study, it is concluded that ZX did not provide a superior anasthesia and analgesia compared to AM in crossbreed pigs. However, these drugs are too expensive for regular use in ambulatory practice. The effects of ZXK resemble those of ZX, but the ZXK-drug combination has no anaesthetic advantages and is more laborious to work with. kw|Keywords|k]azaperone; k]metomidate; k]Zoletil®, xylazine; k]ketamine  相似文献   

12.
ABSTRACT: BACKGROUND: Approximately 25% of hospitalized patients have a urinary catheter, and catheter associated urinary tract infection is the most common nosocomial infection in the US, causing >1 million cases/year. However, the natural history of the biofilms that rapidly form on urinary catheters and lead to infection is not well described. FINDINGS: We characterized the dynamics of catheter colonization among catheters collected from 3 women and 5 men in a trauma burn unit with different indwelling times using TRFLP and culture. All patients received antibiotic therapy. Results: Colony-forming units increased along the extraluminal catheter surface from the catheter balloon to the urethra, but no trend was apparent for the intraluminal surface. This suggests extraluminal bacteria come from periurethral communities while intraluminal bacteria are introduced via the catheter or already inhabit the urine/bladder. Richness of operational taxonomic units (OTUs) increased over time on the intraluminal surface, but was constant extraluminally. CONCLUSIONS: OTU community composition was explained best by time rather than axial location or surface. Our results suggest that catheter colonization can be very dynamic, and possibly have a predictable succession.  相似文献   

13.
Manohar, Murli, and Thomas E. Goetz. Pulmonary vascularpressures of exercising Thoroughbred horses with and without endoscopicevidence of EIPH. J. Appl. Physiol.81(4): 1589-1593, 1996.Exercise-induced pulmonary hemorrhage(EIPH) is a common occurrence in racehorses. The objective of thisstudy was to compare pulmonary vascular pressures of healthyThoroughbred horses with and without postexertion endoscopicallydetectable fresh blood in the trachea. The nasopharynx, larynx, andtrachea (down to the carina) of horses were examined weekly with anendoscope 55-60 min postexertion, and the diagnosis of EIPH wasconfirmed by the presence of fresh blood in the trachea. Measurementsof heart rate and right atrial, pulmonary arterial, and pulmonaryarterial wedge pressures were made during quiet rest and duringtreadmill exercise performed at 14.5 m/s on a 5% uphillgrade. This workload elicited maximal heart rate of thehorses. Mean pulmonary capillary pressure was estimated to be halfwaybetween the mean pulmonary arterial pressure and the mean pulmonaryarterial wedge pressure. These data from 7 healthy soundexercise-trained horses that were positive on 12 consecutive occasions(at 1-wk intervals) for the postexercise presence of fresh blood in thetrachea were compared with those in 8 healthy horses that wereconsistently negative for the evidence of fresh blood in the trachea onpostexercise endoscopic examination over 12-16 wk. The heart rateand the right heart and/or pulmonary vascular pressures in the twogroups of horses were similar at rest. Exercise wasattended by a large significant (P < 0.05) increase in these pressures and heart rate in both groups.However, statistically significant differences between endoscopicallyEIPH-positive and endoscopically EIPH-negative horses for heart rateand right atrial and pulmonary vascular pressures were not found duringexercise. Thus these data revealed that the magnitude ofexercise-induced right atrial as well as pulmonary arterial, capillary,and venous hypertension in endoscopically EIPH-positive horses that areotherwise healthy is quite similar to that in endoscopicallyEIPH-negative horses during comparable exertion.

  相似文献   

14.
We studied collateral flow resistance in exsanguinated, excised lower lobes and accessory lobes of dog and horse lungs, respectively. A double lumen catheter obstructed a peripheral airway isolating a segment of the lobe. Oxygen flowed into the segment via a rotameter which measured flow (Vcoll) while the inner catheter recorded segment pressure (Ps). Gas delivered into the segment flowed out via collateral channels. Collateral flow resistance was calculated as (Ps - PL)/Vcoll, where PL = static transpulmonary pressure. Rcoll at PL = 20, 10, and 5 cm H2O averaged 0.24, 1.25, and 2.65 cmH2O.ml-1.s, respectively, in the dog, and 4.53, 6.00, and 12.62 cmH2O.ml-1.s in the horse. At a given PL, Rcoll measured during inflation. At constant PL, Rcoll increased with time at PL = 5 and 10 cmH2O, but was not time dependent at PL = 20 cmH2O. At constant PL, Rcoll increased at Vcoll increased. We conclude Rcoll is greater in horses than in dogs and is a function of PL, Ps - PL, and lung volume history in both species.  相似文献   

15.
The intratracheal introduction of R. burnetii is the method of infection, highly similar to aerogenic infection, the most widespread route of R. burnetii infection in humans under natural conditions. This suggests that the study of the pathogenesis of Q fever resulting from the intratracheal infection of guinea pigs is highly topical. The authors have established that after the penetration of the infective agent generalized infection develops in the animals with rickettsiae accumulating mostly in the lungs and the organs of the reticuloendothelial system being affected; this infection is commonly more pronounced than that developing after the intraperitoneal inoculation of rickettsiae.  相似文献   

16.
It has earlier been shown that the formol-gel test on serum and glutaraldehyde test on whole blood are simple and rapid methods for evaluation or the immunoglobulin status in the cow. Both tests function as coagulation tests in which aldehyde groups oross-link basic blood globulins at their NH2-groups, forming polymerisates. The glutaraldehyde has in whole blood the capacity to polymerize not only immunoglobulins but also fibrinogen. This investigation was made in order to study whether the fibrinogen level may influence the result of the glutaraldehyde test, so revealing any differences between the results of that and the formol-gel test carried out on serum. In 92 cows with a variety of clinical disorders (most of them with inflammatory processes) the total protein, albumin, total globulin concentration and albumin/globulin ratio in serum and fibrinogen concentration in plasma were recorded. The material was grouped according to glutaraldehyde and formol-gel test reactions. It is shown that increases in the fibrinogen level have an effect on the results of the glutaraldehyde test. A positive glutaraldehyde test in more acute processes is ascribed to a heavy rise of plasma fibrinogen in its capacity of acute-phase protein. A positive glutaraldehyde test in chronic diseases may be viewed as a result of interaction between high immunoglobulin concentrations and elevated fibrinogen concentration. In conclusion the fibrinogen and immunoglobulin status of blood is important to assess in many diseases of cattle. The semiquantitative tests described for field use can separately, or especially in parallel use, provide valuable information about the character and development of a disease and may be regarded as good substitutes for the sedimentation rate (SR), which is not demonstrable in cattle. kw|Keywords|k]bovine fibrinogen; k]bovine serum proteins; k]formol-gel reaction; k]glutaraldehyde test; k]acute and chronic inflammations  相似文献   

17.
Bilateral removal of the olfactory lobes in rats produces a number of behavioral, endocrine, and neurochemical alterations in the brain. Little is known, however, regarding the effects of this treatment on cardiovascular function and autonomic reflexes. Male Sprague-Dawley rats underwent bilateral surgical ablation of the olfactory bulbs (n = 10) or were sham operated (n = 8). After 3 wk of recovery, animals were instrumented with femoral catheters and a lumbar sympathetic nerve recording electrode. After 24 h of recovery, cardiovascular responses to arterial baroreflex manipulation, air jet stress, and smoke exposure were recorded. Olfactory bulbectomized rats demonstrated attenuated sympathoexcitatory responses to hypotension, air jet stress, and smoke exposure, as well as elevated basal blood pressure, compared with sham-operated rats. These data indicate that the integrity of the olfactory bulbs in rats is important for the elicitation of normal cardiovascular and autonomic responses to a number of evocative stimuli.  相似文献   

18.
Controversy continues about the contribution of the veins to pulmonary vascular resistance. From data obtained in studies using intravascular catheters, it appears that a major fraction (up to 44%) of the total pulmonary vascular pressure drop resides in larger (greater than 1.0 mm diam) veins, whereas micropuncture data and various models give much less pressure drop. Theoretically, artifactual pressure drops can be obtained if an intravascular catheter partly obstructs the vessel. We made measurements of pressure in the same lung vein with two different-sized catheters (1.2 and 0.6 mm OD, respectively). In paired experiments the larger catheter always measured a higher pressure than the smaller one, except close to the large lobar vein outlet. In some of the experiments we measured the diameter of the vessel containing the indwelling catheter by freezing the lung and then serial-sectioned the frozen lung. From these data we could infer that the range of vein diameter in the which the smaller catheter measured a lower pressure was 1.5-4 mm. We conclude that the larger catheter overestimated the pressure because of greater obstruction. The pressures obtained with the smaller catheter suggest that little (less than 10%) of the total pulmonary vascular resistance resides in veins larger than approximately 1 mm diam under zone 3 baseline conditions.  相似文献   

19.
Elevated intracranial pressure (ICP) is a significant problem in several forms of ischemic brain injury including stroke, traumatic brain injury and cardiac arrest. This elevation may result in further neurological injury, in the form of transtentorial herniation1,2,3,4, midbrain compression, neurological deficit or increased cerebral infarct2,4. Current therapies are often inadequate to control elevated ICP in the clinical setting5,6,7 . Thus there is a need for accurate methods of ICP measurement in animal models to further our understanding of the basic mechanisms and to develop new treatments for elevated ICP.In both the clinical and experimental setting ICP cannot be estimated without direct measurement. Several methods of ICP catheter insertion currently exist. Of these the intraventricular catheter has become the clinical ''gold standard'' of ICP measurement in humans8. This method involves the partial removal of skull and the instrumentation of the catheter through brain tissue. Consequently, intraventricular catheters have an infection rate of 6-11%9. For this reason, subdural and epidural cannulations have become the preferred methods in animal models of ischemic injury. Various ICP measurement techniques have been adapted for animal models, and of these, fluid-filled telemetry catheters10 and solid state catheters are the most frequently used11,12,13,14,15. The fluid-filled systems are prone to developing air bubbles in the line, resulting in false ICP readings. Solid state probes avoid this problem (Figure 1). An additional problem is fitting catheters under the skull or into the ventricles without causing any brain injury that might alter the experimental outcomes. Therefore, we have developed a method that places an ICP catheter contiguous with the epidural space, but avoids the need to insert it between skull and brain. An optic fibre pressure catheter (420LP, SAMBA Sensors, Sweden) was used to measure ICP at the epidural location because the location of the pressure sensor (at the very tip of the catheter) was found to produce a high fidelity ICP signal in this model. There are other manufacturers of similar optic fibre technologies13 that may be used with our methodology. Alternative solid state catheters, which have the pressure sensor located at the side of the catheter tip, would not be appropriate for this model as the signal would be dampened by the presence of the monitoring screw. Here, we present a relatively simple and accurate method to measure ICP. This method can be used across a wide range of ICP related animal models.  相似文献   

20.
The epidemiology of toxoplasmosis in sheep was studied during a period of 31/2 to 6 years in 4 flocks in which abortions from the infection previously had occurred. The epidemiological pattern indicated that a heavy contamination of the environment may persist for about 2 years. Even in flocks with an apparently normal reproductive performance, toxoplasmosis may cause barrenness, abortion or delivery of dead lambs in 1–2 % of the breeding ewes. The prevalence of infected sheep increased with the age. The incidence of infection was significantly lower in 6–12 months old lambs than in mature ewes. The incidence of infection was higher on lowland pastures than on mountain pastures in not populated areas. On lowland pastures the incidence of infection was lower during the summer than during the winter. kw|Keywords|k]toxoplasma infection; k]epidemiology; k]sheep {fn1|This work was supported by grants from the Norwegian Research Council for Science and for the Humanities.}  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号