首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
It has been hypothesized for over a hundred years that trabecular bone plays an important structural role in the musculoskeletal system of animals and that it responds dynamically to applied loads through growth. The objectives of this study are to quantify the three-dimensional structure of femoral head trabecular bone in a sample of extant strepsirrhines and to relate patterns of interspecific variation to locomotor behavioral differences. The bone volume fraction (BV/TV) and fabric anisotropy of trabecular bone in the femoral heads of Cheirogaleus major, Avahi laniger, Galago senegalensis, Galago alleni, Loris tardigradus, Otolemur crassicaudatus, and Perodicticus potto were quantified in three dimensions using serial high-resolution X-ray computed tomography scan data. A volume based method was used to quantify the structural anisotropy in three cubic samples located inside the central portion of the femoral head. Significant structural differences were found between the predominantly leaping galagines and indriids and the nonleaping lorisines and cheirogaleids. The leapers in general have relatively anisotropic trabecular bone. The galagines display a unique pattern of decreasing bone volume and increasing anisotropy moving from the superior to the inferior half of the femoral head. By contrast, the nonleaping taxa possess relatively uniform and isotropic bone throughout the femoral head. The differences in femoral head trabecular structure among these taxa seem to be related to locomotor behavioral differences, reflecting variation in the use and loading of the hip joint during normal locomotion.  相似文献   

2.
The elastic properties and mechanical behavior of trabecular bone are largely determined by its three-dimensional (3D) fabric structure. Recent work demonstrating a correlation between the primary mechanical and material axes in trabecular bone specimens suggests that fabric orientation may be used to infer directional components of the material strength and, by extension, the hypothetical loading regime. Here we quantify the principal orientation of trabecular bone in the femoral head and relate these principal fabric directions to loading patterns during various locomotor behaviors. The proximal femora of a diverse sample of prosimians were scanned using a high-resolution X-ray computed tomography scanner with resolution of better than 50 mum. Spherical volumes of interest were defined within the femoral heads and the 3D fabric anisotropy was calculated using the mean intercept length and star volume distribution methods. In addition to differences in bone volume and anisotropy, significant differences were found in the spatial orientation of the principal trabecular axes depending on locomotor behavior. The principal orientations for leapers (Galago, Tarsius, Avahi) are relatively tightly clustered (alpha(95) confidence limit: 8.2; angular variance s: 18.2 degrees ) and oriented in a superoanterior direction, while those of nonleapers are more variable across a range of directions (alpha(95): 16.8; s: 42.0 degrees ). The mean principal directions are significantly different for leaping vs. nonleaping taxa. These results further suggest a relationship between bone microstructure in the hip joint and locomotor behavior and indicate a similarity of loading across leapers despite differences in kinematics and phylogeny.  相似文献   

3.
TM Ryan  CN Shaw 《PloS one》2012,7(7):e41037
Understanding the mechanically-mediated response of trabecular bone to locomotion-specific loading patterns would be of great benefit to comparative mammalian evolutionary morphology. Unfortunately, assessments of the correspondence between individual trabecular bone features and inferred behavior patterns have failed to reveal a strong locomotion-specific signal. This study assesses the relationship between inferred locomotor activity and a suite of trabecular bone structural features that characterize bone architecture. High-resolution computed tomography images were collected from the humeral and femoral heads of 115 individuals from eight anthropoid primate genera (Alouatta, Homo, Macaca, Pan, Papio, Pongo, Trachypithecus, Symphalangus). Discriminant function analyses reveal that subarticular trabecular bone in the femoral and humeral heads is significantly different among most locomotor groups. The results indicate that when a suite of femoral head trabecular features is considered, trabecular number and connectivity density, together with fabric anisotropy and the relative proportion of rods and plates, differentiate locomotor groups reasonably well. A similar, yet weaker, relationship is also evident in the trabecular architecture of the humeral head. The application of this multivariate approach to analyses of trabecular bone morphology in recent and fossil primates may enhance our ability to reconstruct locomotor behavior in the fossil record.  相似文献   

4.
The goal of this study was to characterize the trabecular microarchitecture of the femoral head using micro-computed tomography (ICT). Femoral head specimens were obtained from subjects following total hip replacement. Cylindrical cores from the specimens were scanned to obtain 3-D images with an isotropic resolution of 26 Im. Bone structural parameters were evaluated on a per millimeter basis: relative bone volume (BV/TV), trabecular number (Tb.N), thickness (Tb.Th) and separation (Tb.Sp), structure model index (SMI), and connectivity (Conn.D). The ICT data show that the first two millimeters, starting at the joint surface, are characterized by more plate-like trabeculae, and are significantly denser than the underlying trabecular bone. Regional differences in the trabecular architecture reveal that the superior pole has significantly higher BV/TV, Tb.N and Tb.Th values, with lower Tb.Sp compared to the inferior and side poles. Because subchondral bone is essential in the load attenuation of joints, the difference in bone structure between the subchondral and trabecular bone might arise from the different functions each have within joint-forming bones. The denser trabecular structure of the superior pole as compared to the inferior pole can be interpreted as a functional adaptation to higher loading in this area.  相似文献   

5.
Osteoporosis-related vertebral body fractures involve large compressive strains of trabecular bone. The small strain mechanical properties of the trabecular bone such as the elastic modulus or ultimate strength can be estimated using the volume fraction and a second order fabric tensor, but it remains unclear if similar estimations may be extended to large strain properties. Accordingly, the aim of this work is to identify the role of volume fraction and especially fabric in the large strain compressive behavior of human trabecular bone from various anatomical locations. Trabecular bone biopsies were extracted from human T12 vertebrae (n=31), distal radii (n=43), femoral head (n=44), and calcanei (n=30), scanned using microcomputed tomography to quantify bone volume fraction (BV/TV) and the fabric tensor (M), and tested either in unconfined or confined compression up to very large strains (~70%). The mechanical parameters of the resulting stress-strain curves were analyzed using regression models to examine the respective influence of BV/TV and fabric eigenvalues. The compressive stress-strain curves demonstrated linear elasticity, yielding with hardening up to an ultimate stress, softening toward a minimum stress, and a steady rehardening followed by a rapid densification. For the pooled experiments, the average minimum stress was 1.89 ± 1.77 MPa, while the corresponding mean strain was 7.15 ± 1.84%. The minimum stress showed a weaker dependence with fabric as the elastic modulus or ultimate strength. For the confined experiments, the stress at a logarithmic strain of 1.2 was 8.08 ± 7.91 MPa, and the dissipated energy density was 5.67 ± 4.42 MPa. The latter variable was strongly related to the volume fraction (R(2)=0.83) but the correlation improved only marginally with the inclusion of fabric (R(2)=0.84). The influence of fabric on the mechanical properties of human trabecular bone decreases with increasing strain, while the role of volume fraction remains important. In particular, the ratio of the minimum versus the maximum stress, i.e., the relative amount of softening, decreases strongly with fabric, while the dissipated energy density is dominated by the volume fraction. The collected results will prove to be useful for modeling the softening and densification of the trabecular bone using the finite element method.  相似文献   

6.
There have been reports both supporting and refuting an inverse relationship between hip fracture and hip osteoarthritis (OA). We have investigated this relationship using histomorphometric study of femoral head subchondral bone. We studied 74 subjects with hip fracture (74% females) and 24 subjects with osteoarthritis (45% females). By histomorphometric analysis of parafined sections, we analysed followed subhondral trabecular bone parameters bone volume (BV), bone volume/tissue volume (BV/TV), trabecular thickness (Tb.Th.), trabecular number (Tb.N.) and trabecular separation (Tb.S.). The subjects with osteoarthritis and subjects with hip fracture had BV/TV 31.3% and 19.6% respectively. BV/TV of osteoarthritis group was rather uniform whereas BV/TV of hip fracture group was greatly ranged and we divided it into three subgroups, 13.2%, 19.8% and 25.9% respectively. The OA group and hip fracture groups had Tb.Th. as followed 0.205 mm, 0.148 mm, 0.170 mm and 0.183 mm respectively. The OA group and hip fracture three subgroups had Tb.N. as followed 1.454/mm, 0.897/mm, 1.170/mm and 1.425/mm respectively. The OA group and hip fracture three subgroups had Tb.S. as followed 0.518 mm, 0.681 mm, 0.620 mm and 0.550 mm respectively. The results of our study support an inverse relationship between hip fracture and hip osteoarthritis.  相似文献   

7.
It has been demonstrated in clinical and experimental studies that subarticular trabecular bone responds to mechanical loads transmitted across joints through changes in mass and structural organization. We investigated differences in mass, volume, and density of subarticular trabecular bone of the humeral and femoral head in Hylobates syndactylus, Colobus guereza, and Papio cynocephalus. Our hypothesis was that variations in trabecular properties between taxa may reflect differences in mechanical loading associated with different locomotor repertoires. A nondestructive method for measuring trabecular properties using optical luminance data measured from radiographs was developed. We also examined the relationship between internal trabecular properties and the external size and surface area of the humeral and femoral heads in these taxa. Our results suggest that internal and external articular structure are relatively independent of each other and may be adapted to different aspects of the mechanical environment. Differences in trabecular mass between taxa appear to correspond to differences in the magnitudes of mechanical loads borne by the joint, whereas aritcular volume and surface area are related primarily to differences in joint mobility. Because of the apparent physiological “de-coupling” of articular mass and volume, variations in articular density (mass/volume) are difficult to interpret in isolation. Comparisons of internal and external articular structure may provide new ways to reconstruct the locomotor/positional behavior of extinct taxa. © 1994 Wiley-Liss, Inc.  相似文献   

8.
Different lines of evidence suggest that trabecular bone architecture contains a functional signal related to an organism's locomotor behavior. An understanding of the interspecific and intraspecific variation in extant nonhuman primate trabecular structure is needed to evaluate its usefulness as a tool to reconstruct the locomotor habits of extinct primates. High-resolution X-ray computed tomography (HRXCT) is a new imaging approach with a resolution in the tens of microns that allows nondestructive access to the internal structure of bony elements. Previous studies indicate that such resolution is necessary to accurately quantify structural parameters of trabecular bone. The primary goal of this study was to test the accuracy of HRXCT by comparing stereological measurements from HRXCT images and histological thin sections of cancellous bone taken from the proximal femur and humerus of baboons. To this end, 11 bone samples were scanned on an HRXCT scanner and then thin-sectioned to reveal the scanned plane. HRXCT images were thresholded using a modified half-maximum height protocol. The stereological measurements included bone volume fraction (BV/TV), trabecular number (Tb.N), bone surface to volume ratio (BS/BV), trabecular thickness (Tb.Th), and trabecular spacing (Tb.Sp). The measurement errors on the HRXCT images were 10.90% for BV/TV, 6.06% for Tb.N, 14.19% for BS/BV, 14.33% for Tb.Th, and 7.09% for Tb.Sp, but none of these measurements were significantly different from the histological standards (alpha = 0.05). A second goal of this study was to examine the influence of thresholding, a necessary step in any morphometric study using computed tomography, on the accuracy of the quantitative morphometry. Threshold values derived from a modified half-maximum height protocol showed that parameters derived from the region of interest (area in which stereological measurements were later taken) produced better reconstructions of the actual bone structure than threshold values derived from more inclusive areas of bone. We conclude that HRXCT can accurately reconstruct the complex architecture of trabecular bone, and that thresholding is a nontrivial step in trabecular bone studies, with even slight changes in the protocol greatly affecting the morphometric data. HRXCT represents a valuable analytical tool that should be of interest to a great many researchers in physical anthropology because it allows nondestructive access to internal morphology, thereby preserving valuable and limited skeletal collections.  相似文献   

9.
Work on the interspecific and intraspecific variation of trabecular bone in the proximal femur of primates demonstrates important architectural variation between animals with different locomotor behaviors. This variation is thought to be related to the processes of bone adaptation whereby bone structure is optimized to the mechanical environment. Micromechanical finite element models were created for the proximal femur of the leaping Galago senegalensis and the climbing and quadrupedal Loris tardigradus by converting bone voxels from high-resolution X-ray computed tomography scans of the femoral head to eight-noded brick elements. The resulting models had approximately 1.8 million elements each. Loading conditions representing takeoff phase of a leap and more generalized load orientations were applied to the models, and the models were solved using the iterative "row-by-row" matrix-vector multiplication algorithm. The principal strain and Von Mises stress results for the leaping model were similar for both species at each load orientation. Similar hip joint reaction forces in the range of 4.9 x to 12 x body weight were calculated for both species under each loading condition, but the hip reaction values estimated for Loris were higher than predicted based on locomotor behavior. These results suggest that functional adaptation to hip joint loading may not fully explain the differences in femoral head trabecular bone structure in Galago and Loris. The finite element method represents a unique and useful tool for analyzing the functional adaptation of trabecular bone in a diversity of animals and for reconstructing locomotor behavior in extinct taxa.  相似文献   

10.
In the context of reconciling the mechanical properties of trabecular bone measured from in vitro mechanical testing with the true in situ behavior, recent attention has focused on the "side-artifact" which results from interruption of the trabecular network along the sides of machined specimens. The objective of this study was to compare the magnitude of the side-artifact error for measurements of elastic modulus vs. yield stress and to determine the dependence of these errors on anatomic site and trabecular micro-architecture. Using a series of parametric variations on micro-CT-based finite element models of trabecular bone from the human vertebral body (n=24) and femoral neck (n=10), side-artifact correction factors were quantified as the ratio of the side-artifact-free apparent mechanical property to the corresponding property measured in a typical experiment. The mean (+/-SD) correction factors for yield stress were 1.32+/-0.17 vs. 1.20+/-0.11 for the vertebral body and femoral neck (p<0.05), respectively, and the corresponding factors for modulus were 1.24+/-0.09 vs. 1.10+/-0.04 (p<0.0001). Correction factors were greater for yield stress than modulus (p<0.003), but no anatomic site effect was detected (p>0.29) after accounting for variations in bone volume fraction (BV/TV). Approximately 30-55% of the variation in the correction factors for modulus and yield stress could be accounted for by BV/TV or micro-architecture, representing an appreciable systematic component of the error. Although some scatter in the correction factor-BV/TV relationships may confound accurate correction of modulus and yield stress for individual specimens, side-artifact correction is nonetheless essential for obtaining accurate mean estimates of modulus and yield stress for a cohort of specimens. We conclude that appreciation and correction for the differential effects of the side-artifact in modulus vs. yield stress and their dependence on BV/TV may improve the interpretation of measured elastic and failure properties for trabecular bone.  相似文献   

11.
Innovations in micro-computed tomography (microCT) in the medical field have resulted in the development of techniques that allow the precise quantification of bone density and fabric related parameters of trabecular bone. For the purpose of this study, the technique was applied to a small sample of Perodicticus potto and Galago senegalensis femora to see if differences in loading environment elicit the predicted effects on trabecular structure. While the overall bone volume was approximately three times larger in the potto, there was no significant difference in the apparent volume density in the two taxa. When regional differences in the proximal femur were examined, the cancellous bone of the femoral head of Perodicticus potto and Galago senegalensis, while not differing in volume density, showed differences in trabecular orientation, with the potto having more randomly oriented trabeculae than the bushbaby. This was as hypothesized, given that the bushbaby submits its femora to more stereotypical loading environments than the potto. In the femoral neck, the cancellous bone was not only more randomly oriented, it was also denser in the potto compared with the bushbaby. This suggests that trabecular morphology may be extremely sensitive to certain differences in the loading environment and that this information, combined with information on cortical bone structure and external geometry, will result in a more complete understanding of how bone shape and composition correspond to loading and locomotor patterns. Ultimately, a synthesis of these different lines of evidence may have considerable applications in paleontological studies that attempt to reconstruct bone use from morphology.  相似文献   

12.
Bone is capable of adapting during life in response to stress. Therefore, variation in locomotor and manipulative behaviours across extant hominoids may be reflected in differences in trabecular bone structure. The hand is a promising region for trabecular analysis, as it is the direct contact between the individual and the environment and joint positions at peak loading vary amongst extant hominoids. Building upon traditional volume of interest-based analyses, we apply a whole-epiphysis analytical approach using high-resolution microtomographic scans of the hominoid third metacarpal to investigate whether trabecular structure reflects differences in hand posture and loading in knuckle-walking (Gorilla, Pan), suspensory (Pongo, Hylobates and Symphalangus) and manipulative (Homo) taxa. Additionally, a comparative phylogenetic method was used to analyse rates of evolutionary changes in trabecular parameters. Results demonstrate that trabecular bone volume distribution and regions of greatest stiffness (i.e., Young''s modulus) correspond with predicted loading of the hand in each behavioural category. In suspensory and manipulative taxa, regions of high bone volume and greatest stiffness are concentrated on the palmar or distopalmar regions of the metacarpal head, whereas knuckle-walking taxa show greater bone volume and stiffness throughout the head, and particularly in the dorsal region; patterns that correspond with the highest predicted joint reaction forces. Trabecular structure in knuckle-walking taxa is characterised by high bone volume fraction and a high degree of anisotropy in contrast to the suspensory brachiators. Humans, in which the hand is used primarily for manipulation, have a low bone volume fraction and a variable degree of anisotropy. Finally, when trabecular parameters are mapped onto a molecular-based phylogeny, we show that the rates of change in trabecular structure vary across the hominoid clade. Our results support a link between inferred behaviour and trabecular structure in extant hominoids that can be informative for reconstructing behaviour in fossil primates.  相似文献   

13.
Understanding the off-axis behavior of trabecular yield strains may lend unique insight into the etiology of fractures since yield strains provide measures of failure independent of elastic behavior. We sought to address anisotropy of trabecular yield strains while accounting for variations in both density and anatomic site and to determine the mechanisms governing this behavior. Cylindrical specimens were cored from vertebral bodies (n=22, BV/TV=0.11±0.02) and femoral necks (n=28, BV/TV=0.22±0.06) with the principal trabecular orientation either aligned along the cylinder axis (on-axis, n=22) or at an oblique angle of 15° or 45° (off-axis, n=28). Each specimen was scanned with micro-CT, mechanically compressed to failure, and analysed with nonlinear micro-CT-based finite element analysis. Yield strains depended on anatomic site (p=0.03, ANOVA), and the effect of off-axis loading was different for the two sites (p=0.04)—yield strains increased for off-axis loading of the vertebral bone (p=0.04), but were isotropic for the femoral bone (p=0.66). With sites pooled together, yield strains were positively correlated with BV/TV for on-axis loading (R2=58%, p<0.0001), but no such correlation existed for off-axis loading (p=0.79). Analysis of the modulus-BV/TV and strength-BV/TV relationships indicated that, for the femoral bone, the reduction in strength associated with off-axis loading was greater than that for modulus, while the opposite trend occurred for the vertebral bone. The micro-FE analyses indicated that these trends were due to different failure mechanisms for the two types of bone and the different loading modes. Taken together, these results provide unique insight into the failure behavior of human trabecular bone and highlight the need for a multiaxial failure criterion that accounts for anatomic site and bone volume fraction.  相似文献   

14.
Hindlimb suspension is the most used model for inducing bone loss from unloading but requires a separate ground control group. This control group cannot be used for genetic studies involving outbred mice. In this study, we evaluated a single limb immobilization (SLI) model for inducing bone loss from unloading, with the contralateral limb from the same animal used as a control. Male 10-week old C57Bl/6J mice had one limb immobilized for one, two, or three weeks. Subsequently, an additional group of male 16-week old C57Bl/6J mice had one limb immobilized for three weeks. SLI resulted in decreased tibial trabecular BV/TV, Tb Th, and Tb N compared to contralateral limbs in young mice. Femoral trabecular BV/TV, Tb Th, Tb N, and femoral cortical area fraction were also decreased. Mechanical properties were not affected after three weeks. In adult mice, femoral trabecular BV/TV, Tb Th, and Tb N were decreased. Femoral stiffness, ultimate stress, and Young’s modulus were decreased. Bone properties decreased by SLI were also decreased by hindlimb suspension previously. The results suggest SLI can be an effective model for inducing bone loss in growing and adult mice after three weeks of immobilization.  相似文献   

15.
The purpose of the present study was to compare the effects of alendronate and alfacalcidol on cancellous and cortical bone mass and bone mechanical properties in ovariectomized rats. Twenty-six female Sprague-Dawley rats, 7 months of age, were randomized by the stratified weight method into four groups: the sham-operated control (Sham) group and the three ovariectomy (OVX) groups, namely, OVX + vehicle, OVX + alendronate (2.5 mg/kg, p.o., daily), and OVX + alfacalcidol (0.5 mug/kg, p.o., daily). At the end of the 8-week experimental period, bone histomorphometric analyses of cancellous bone at the proximal tibial metaphysis and cortical bone at the tibial diaphysis were performed, and the mechanical properties of the femoral distal metaphysis and femoral diaphysis were evaluated. OVX decreased cancellous bone volume per total tissue volume (BV/TV), and the maximum load of the femoral distal metaphysis, as a result of increases in serum osteocalcin (OC) levels, and also the number of osteoclasts (N.Oc), osteoclast surface (OcS) and bone formation rate (BFR) per bone surface (BS), and BFR/BV, without any effect on cortical area (Ct Ar), or maximum load of the femoral diaphysis. Alendronate prevented this decrease in cancellous BV/TV by suppressing increases in N.Oc/BS, OcS/BS, BFR/BS, and BFR/BV, without any apparent effect on Ct Ar, or maximum load of the femoral distal metaphysis and femoral diaphysis. On the other hand, alfacalcidol increased cancellous BV/TV, Ct Ar, and the maximum load of the femoral distal metaphysis and femoral diaphysis, by mildly decreasing trabecular BFR/BV, maintaining trabecular mineral apposition rate and osteoblast surface per BS, increasing periosteal and endocortical BFR/BS, and preventing an increase in endocortical eroded surface per BS. The present study clearly showed the differential skeletal effects of alendronate and alfacalcidol in ovariectomized rats. Alendronate prevented OVX-induced cancellous bone loss by suppressing bone turnover, while alfacalcidol improved cancellous and cortical bone mass and bone strength by suppressing bone resorption and maintaining or even increasing bone formation.  相似文献   

16.
ObjectiveThis study used microcomputed tomography (micro-CT) to evaluate the effects of ovariectomy on the trabecular bone microarchitecture and cortical bone morphology in the femoral neck and mandible of female rats.ResultsRegarding the trabecular bone microarchitectural parameters, the BV/TV of the trabecular bone microarchitecture in the femoral necks of the control group (61.199±11.288%, median ± interquartile range) was significantly greater than that of the ovariectomized group (40.329±5.153%). Similarly, the BV/TV of the trabecular bone microarchitecture in the mandibles of the control group (51.704±6.253%) was significantly greater than that of the ovariectomized group (38.486±9.111%). Furthermore, the TbSp of the femoral necks in the ovariectomized group (0.185±0.066 mm) was significantly greater than that in the control group (0.130±0.026mm). Similarly, the TbSp of the mandibles in the ovariectomized group (0.322±0.047mm) was significantly greater than that in the control group (0.285±0.041mm). However, the TbTh and TbN trends for the mandibles and femoral necks were inconsistent between the control and ovariectomized groups. Regarding the cortical bone morphology parameters, the TtAr of the femoral necks in the ovariectomized group was significantly smaller than that in the control group. There was no significant difference in the TtAr, CtAr, or CtTh of the femoral necks between the control and ovariectomized groups, and no significant difference in the CtTh of the mandibles between the control and ovariectomized groups. Moreover, the BV/TV and TbSp of the mandibles were highly correlated with those of the femurs (rs = 0.874 and rs = 0.755 for BV/TV and TbSp, respectively). Nevertheless, the TbTh, TbN, and CtTh of the mandibles were not correlated with those of the femoral necks.ConclusionAfter the rats were ovariectomized, osteoporosis of the trabecular bone microarchitecture occurred in their femurs and mandibles; however, ovariectomy did not influence the cortical bone morphology. In addition, the parametric values of the trabecular bone microarchitecture in the femoral necks were highly correlated with those of the trabecular bone microarchitecture in the mandibles.  相似文献   

17.
Although the correspondence between habitual activity and diaphyseal cortical bone morphology has been demonstrated for the fore- and hind-limb long bones of primates, the relationship between trabecular bone architecture and locomotor behavior is less certain. If sub-articular trabecular and diaphyseal cortical bone morphology reflects locomotor patterns, this correspondence would be a valuable tool with which to interpret morphological variation in the skeletal and fossil record. To assess this relationship, high-resolution computed tomography images from both the humeral and femoral head and midshaft of 112 individuals from eight anthropoid genera (Alouatta, Homo, Macaca, Pan, Papio, Pongo, Trachypithecus, and Symphalangus) were analyzed. Within-bone (sub-articular trabeculae vs. mid-diaphysis), between-bone (forelimb vs. hind limb), and among-taxa relative distributions (femoral:humeral) were compared. Three conclusions are evident: (1) Correlations exists between humeral head sub-articular trabecular bone architecture and mid-humerus diaphyseal bone properties; this was not the case in the femur. (2) In contrast to comparisons of inter-limb diaphyseal bone robusticity, among all species femoral head trabecular bone architecture is significantly more substantial (i.e., higher values for mechanically relevant trabecular bone architectural features) than humeral head trabecular bone architecture. (3) Interspecific comparisons of femoral morphology relative to humeral morphology reveal an osteological "locomotor signal" indicative of differential use of the forelimb and hind limb within mid-diaphysis cortical bone geometry, but not within sub-articular trabecular bone architecture.  相似文献   

18.
Trabecular (or cancellous) bone has been shown to respond to mechanical loading throughout ontogeny and thus can provide unique insight into skeletal function and locomotion in comparative studies of living and fossil mammalian morphology. Trabecular bone of the hand may be particularly functionally informative because the hand has more direct contact with the substrate compared with the remainder of the forelimb during locomotion in quadrupedal mammals. This study investigates the trabecular structure within the wrist across a sample of haplorhine primates that vary in locomotor behaviour (and thus hand use) and body size. High‐resolution microtomographic scans were collected of the lunate, scaphoid, and capitate in 41 individuals and eight genera (Homo, Gorilla, Pan, Papio, Pongo, Symphalangus, Hylobates, and Ateles). We predicted that particular trabecular parameters would 1) vary across suspensory, quadrupedal, and bipedal primates based on differences in hand use and load, and 2) scale with carpal size following similar allometric patterns found previously in other skeletal elements across a larger sample of mammals and primates. Analyses of variance (trabecular parameters analysed separately) and principal component analyses (trabecular parameters analysed together) revealed no clear functional signal in the trabecular structure of any of the three wrist bones. Instead, there was a large degree of variation within suspensory and quadrupedal locomotor groups, as well as high intrageneric variation within some taxa, particularly Pongo and Gorilla. However, as predicted, Homo sapiens, which rarely use their hands for locomotion and weight support, were unique in showing lower relative bone volume (BV/TV) compared with all other taxa. Furthermore, parameters used to quantify trabecular structure within the wrist scale with size generally following similar allometric patterns found in trabeculae of other mammalian skeletal elements. We discuss the challenges associated with quantifying and interpreting trabecular bone within the wrist. J. Morphol. 275:572–585, 2014. © 2013 Wiley Periodicals, Inc.  相似文献   

19.
For comparative 3D microCT studies of trabecular bone, the use of a volume of interest (VOI) scaled to body size may avoid over-sampling the trabecular mass in smaller versus larger-bodied taxa and comparison of regions that are not functionally homologous (Fajardo and Müller: Am J Phys Anthropol 115 (2001) 327-336), though the influence on quantitative analyses using scaled versus nonscaled VOIs remains poorly characterized. We compare trabecular architectural properties reflecting mass, organization, and orientation from three volumes of interest (large, scaled, and small) obtained from the distal first metacarpal in a sample of Homo (n = 10) and Pan (n = 12). We test the null hypotheses that neither absolute VOI size, nor scaling of the VOI to metacarpal size as a proxy for body size, biases intraspecific analyses nor impacts the detection of interspecific differences. These hypotheses were only partially supported. While certain properties (e.g., bone volume fraction or trabecular thickness) were not affected by varying VOI size within taxa, others were significantly impacted (e.g., intersection surface, connectivity, and structure). In comparing large versus scaled VOIs, we found that the large VOI inflated the number and/or magnitude of significant differences between Homo and Pan. In summary, our results support the use of scaled VOIs in studies of trabecular architecture.  相似文献   

20.
Trabecular bone structure may complement bone volume/total volume fraction (BV/TV) in the prediction of the mechanical properties. Nonetheless, the direct in vivo use of information pertaining to trabecular bone structure necessitates some predictive analytical model linking structure measures to mechanical properties. In this context, the purpose of this study was to combine BV/TV and topological parameters so as to better estimate the mechanical properties of trabecular bone. Thirteen trabecular bone mid-sagittal sections were imaged by magnetic resonance (MR) imaging at the resolution of 117 x 117x 300 microm(3). Topological parameters were evaluated in applying the 3D-line skeleton graph analysis (LSGA) technique to the binary MR images. The same images were used to estimate the elastic moduli by finite element analysis (FEA). In addition to the mid-sagittal section, two cylindrical samples were cored from each vertebra along vertical and horizontal directions. Monotonic compression tests were applied to these samples to measure both vertical and horizontal ultimate stresses. BV/TV was found as a strong predictor of the mechanical properties, accounting for 89-94% of the variability of the elastic moduli and for 69-86% of the variability of the ultimate stresses. Topological parameters and BV/TV were combined following two analytical formulations, based on: (1) the normalization of the topological parameters; and on (2) an exponential fit-model. The normalized parameters accounted for 96-98% of the variability of the elastic moduli, and the exponential model accounted for 80-95% of the variability of the ultimate stresses. Such formulations could potentially be used to increase the prediction of the mechanical properties of trabecular bone.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号