The hemodynamic and the thrombogenic performance of two commercially available bileaflet mechanical heart valves (MHVs)--the ATS Open Pivot Valve (ATS) and the St. Jude Regent Valve (SJM), was compared using a state of the art computational fluid dynamics-fluid structure interaction (CFD-FSI) methodology. A transient simulation of the ATS and SJM valves was conducted in a three-dimensional model geometry of a straight conduit with sudden expansion distal the valves, including the valve housing and detailed hinge geometry. An aortic flow waveform (60 beats/min, cardiac output 4 l/min) was applied at the inlet. The FSI formulation utilized a fully implicit coupling procedure using a separate solver for the fluid problem (FLUENT) and for the structural problem. Valve leaflet excursion and pressure differences were calculated, as well as shear stress on the leaflets and accumulated shear stress on particles released during both forward and backward flow phases through the open and closed valve, respectively. In contrast to the SJM, the ATS valve opened to less than maximal opening angle. Nevertheless, maximal and mean pressure gradients and velocity patterns through the valve orifices were comparable. Platelet stress accumulation during forward flow indicated that no platelets experienced a stress accumulation higher than 35 dyne x s/cm2, the threshold for platelet activation (Hellums criterion). However, during the regurgitation flow phase, 0.81% of the platelets in the SJM valve experienced a stress accumulation higher than 35 dyne x s/cm2, compared with 0.63% for the ATS valve. The numerical results indicate that the designs of the ATS and SJM valves, which differ mostly in their hinge mechanism, lead to different potential for platelet activation, especially during the regurgitation phase. This numerical methodology can be used to assess the effects of design parameters on the flow induced thrombogenic potential of blood recirculating devices.  相似文献   

2.
Performance of a cardiac assist device pumping chamber in counterpulsation was evaluated using numerical simulations of the unsteady, three-dimensional flow inside the chamber and an analytical model of the force required to eject and fill the chamber. The wall shear stress within the device was similarly computed and modeled. The analytical model was scaled to match the numerical results and then used to predict performance at physiological operating conditions. According to these models for a stroke volume of 70 ml, between 0.4 and 1.0 W is required for counterpulsation at a frequency of 1.33 Hz against a restorative spring, depending on the spring constant chosen. The power and the maximum force calculated are within the ranges a trained skeletal muscle is capable of providing. Shear stress predictions show that platelet activation in the absence of surface effects and hemolysis due to high shear are unlikely to occur with this design. Furthermore, vortices that develop in the chamber during filling are predicted to increase blood mixing and provide favorable washing of the chamber walls. A computational-analytical approach such as this may have potential to aid rapid performance evaluation of new devices and streamline the design optimization process.  相似文献   

3.
Thrombus formation is a major concern for recipients of mechanical heart valves (MHVs), which requires them to take anticoagulant drugs for the rest of their lives. Bioprosthetic heart valves (BHVs) do not require life-long anticoagulant therapy but deteriorate after 10–15 years. The thrombus formation is initiated by the platelet activation which is thought to be mainly generated in MHVs by the flow through the hinge and the leakage flow during the diastole. However, our results show that the activation in the bulk flow during the systole phase might play an essential role as well. This is based on our results obtained by comparing the thrombogenic performance of a MHV and a BHV (as control) in terms of shear induced platelet activation under exactly the same conditions. Three different mathematical activation models including linear level of activation, damage accumulation, and Soares model are tested to quantify the platelet activation during systole using the previous simulations of the flow through MHV and BHV in a straight aorta under the same physiologic flow conditions. Results indicate that the platelet activation in the MHV at the beginning of the systole phase is slightly less than the BHV. However, at the end of the systole phase the platelet activation by the bulk flow for the MHV is several folds (1.41, 5.12, and 2.81 for linear level of activation, damage accumulation, and Soares model, respectively) higher than the BHV for all tested platelet activation models.  相似文献   

4.
Patients who receive prosthetic heart valve (PHV) implants require mandatory anticoagulation medication after implantation due to the thrombogenic potential of the valve. Optimization of PHV designs may facilitate reduction of flow-induced thrombogenicity and reduce or eliminate the need for post-implant anticoagulants. We present a methodology entitled Device Thrombogenicty Emulator (DTE) for optimizing the thrombo-resistance performance of PHV by combining numerical and experimental approaches. Two bileaflet mechanical heart valves (MHV) designs, St. Jude Medical (SJM) and ATS, were investigated by studying the effect of distinct flow phases on platelet activation. Transient turbulent and direct numerical simulations (DNS) were conducted, and stress loading histories experienced by the platelets were calculated along flow trajectories. The numerical simulations indicated distinct design dependent differences between the two valves. The stress loading waveforms extracted from the numerical simulations were programmed into a hemodynamic shearing device (HSD), emulating the flow conditions past the valves in distinct ‘hot-spot’ flow regions that are implicated in MHV thrombogenicity. The resultant platelet activity was measured with a modified prothrombinase assay, and was found to be significantly higher in the SJM valve, mostly during the regurgitation phase. The experimental results were in excellent agreement with the calculated platelet activation potential. This establishes the utility of the DTE methodology for serving as a test bed for evaluating design modifications for achieving better thrombogenic performance for such devices.  相似文献   

5.
In the present study, theoretical formulations for calculation of optimal bifurcation angle and relationship between the diameters of mother and daughter vessels using the power law model for non-Newtonian fluids are developed. The method is based on the distribution of wall shear stress in the mother and daughter vessels. Also, the effect of distribution of wall shear stress on the minimization of energy loss and flow resistance is considered. It is shown that constant wall shear stress in the mother and daughter vessels provides the minimum flow resistance and energy loss of biological flows. Moreover, the effects of different wall shear stresses in the mother and daughter branches, different lengths of daughter branches in the asymmetric bifurcations and non-Newtonian effect of biological fluid flows on the bifurcation angle and the relationship between the diameters of mother and daughter branches are considered. Using numerical simulations for non-Newtonian models such as power law and Carreau models, the effects of optimal bifurcation angle on the pressure drop and flow resistance of blood flow in the symmetric bifurcation are investigated. Numerical simulations show that optimal bifurcation angle decreases the pressure drop and flow resistance especially for bifurcations at large Reynolds number.  相似文献   

6.
Arteries with high-grade stenoses may compress under physiologic conditions due to negative transmural pressure caused by high-velocity flow passing through the stenoses. To quantify the compressive conditions near the stenosis, a nonlinear axisymmetric model with fluid-wall interactions is introduced to simulate the viscous flow in a compliant stenotic tube. The nonlinear elastic properties of the tube (tube law) are measured experimentally and used in the model. The model is solved using ADINA (Automatic Dynamic Incremental Nonlinear Analysis), which is a finite element package capable of solving problems with fluid-structure interactions. Our results indicate that severe stenoses cause critical flow conditions such as negative pressure and high and low shear stresses, which may be related to artery compression, plaque cap rupture, platelet activation, and thrombus formation. The pressure filed near a stenosis has a complex pattern not seen in one-dimensional models. Negative transmural pressure as low as -24 mmHg for a 78 percent stenosis by diameter is observed at the throat of the stenosis for a downstream pressure of 30 mmHg. Maximum shear stress as a high as 1860 dyn/cm2 occurs at the throat of the stenoses, while low shear stress with reversed direction is observed right distal to the stenosis. Compressive stresses are observed inside the tube wall. The maximal principal stress and hoop stress in the 78 percent stenosis are 80 percent higher than that from the 50 percent stenosis used in our simulation. Flow rates under different pressure drop conditions are calculated and compared with experimental measurements and reasonable agreement is found for the prebuckling stage.  相似文献   

7.
Ventricular assist devices (VADs) have already helped many patients with heart failure but have the potential to assist more patients if current problems with blood damage (hemolysis, platelet activation, thrombosis and emboli, and destruction of the von Willebrand factor (vWf)) can be eliminated. A step towards this goal is better understanding of the relationships between shear stress, exposure time, and blood damage and, from there, the development of numerical models for the different types of blood damage to enable the design of improved VADs. In this study, computational fluid dynamics (CFD) was used to calculate the hemodynamics in three clinical VADs and two investigational VADs and the shear stress, residence time, and hemolysis were investigated. A new scalar transport model for hemolysis was developed. The results were compared with in vitro measurements of the pressure head in each VAD and the hemolysis index in two VADs. A comparative analysis of the blood damage related fluid dynamic parameters and hemolysis index was performed among the VADs. Compared to the centrifugal VADs, the axial VADs had: higher mean scalar shear stress (sss); a wider range of sss, with larger maxima and larger percentage volumes at both low and high sss; and longer residence times at very high sss. The hemolysis predictions were in agreement with the experiments and showed that the axial VADs had a higher hemolysis index. The increased hemolysis in axial VADs compared to centrifugal VADs is a direct result of their higher shear stresses and longer residence times. Since platelet activation and destruction of the vWf also require high shear stresses, the flow conditions inside axial VADs are likely to result in more of these types of blood damage compared with centrifugal VADs.  相似文献   

8.

The ability of a blood clot to modulate blood flow is determined by the clot’s resistance, which depends on its structural features. For a flow with arterial shear, we investigated the characteristic patterns relating to clot shape, size, and composition on the one hand, and its viscous resistance, intraclot axial flow velocity, and shear distributions on the other. We used microfluidic technology to measure the kinetics of platelet, thrombin, and fibrin accumulation at a thrombogenic surface coated with collagen and tissue factor (TF), the key clot-formation trigger. We subsequently utilized the obtained data to perform additional calibration and validation of a detailed computational fluid dynamics model of spatial clot growth under flow. We then ran model simulations to gain insights into the resistance of clots formed under our experimental conditions. We found that increased thrombogenic surface length and TF surface density enhanced the bulk thrombin and fibrin generation in a nonadditive, synergistic way. The height of the platelet deposition domain—and, therefore, clot occlusivity—was rather robust to thrombogenic surface length and TF density variations, but consistently increased with time. Clot viscous resistance was non-uniform and tended to be higher in the fibrin-rich, inner “core” region of the clot. Interestingly, despite intraclot structure and viscous resistance variations, intraclot flow velocity variations were minor compared to the abrupt decrease in flow velocity around the platelet deposition region. Our results shed new light on the connection between the structure of clots under arterial shear and spatiotemporal variations in their resistance to flow.

  相似文献   

9.
Hemodynamic shear is known to stimulate blood and endothelial cells and induce platelet activation. Many studies of shear-induced platelet stimulation have employed rotational viscometers in which secondary flow effects are assumed to be negligible. Shear induced platelet activation occurs at elevated shear rates where secondary flows may contribute a significant percentage of the total hydrodynamic force experienced by the sample. Elongational stress, one component of this secondary flow, has been shown to alter transmembrane ion flux in intact cell and the permeability of synthetic membrane preparations. Elongational flow also occurs in the vasculature at sites of elevated shear stress. Secondary flow components may contribute to platelet activation induced during shear stress application in rotational viscometry. A unique 'constrained convergence' elongational flow chamber was designed and fabricated to study platelet response to elongational stress exposure. The elongational flow chamber was capable of producing an elongation rate of 2.1 s-1 with a corresponding volume averaged shear rate of 58.33 s-1. Significant changes were observed in the total platelet volume distribution and measured response to added chemical antagonists after elongational stress exposure. The total platelet volume histogram shifted toward larger particle sizes, suggesting the formation of large aggregates as a result of elongational stress exposure. Platelets exposed to elongational stress demonstrated a dose dependent decrease in added ADP-induced aggregation rate and extent of aggregation.  相似文献   

10.
Experiments with glass models of arterial branchings and bends, perfused with bovine platelet rich plasma (PRP), revealed platelet deposition being strongly dependent on fluid dynamic factors. Predilection sites of platelet deposits are characterized by flow vectors directed against the wall, so-called stagnation point flow. Thus collision of suspended particles with the wall, an absolute prerequisite for adhesion of platelets to surfaces even as thrombogenic as glass, appears mediated by convective forces. The extent of platelet deposition is correlated to the magnitude of flow components normal to the surface as well as to the state of biological activation of the platelets. The latter could be effective by an increase in hydrodynamically effective volume, invariably associated with the platelet shape change reaction to biochemical stimulants like ADP. The effect of altered rheological properties of platelets upon their deposition and of mechanical properties of surfaces was examined in a stagnation point flow chamber. Roughnesses in the order of 5 microns, probably by creating local flow disturbances, significantly enhance platelet adhesion, as compared to a smooth surface of identical chemical composition.  相似文献   

11.
This paper presents Computational fluid dynamic (CFD) analysis of blood flow in three different 3-D models of left coronary artery (LCA). A comparative study of flow parameters (pressure distribution, velocity distribution and wall shear stress) in each of the models is done for a non-Newtonian (Carreau) as well as the Newtonian nature of blood viscosity over a complete cardiac cycle. The difference between these two types of behavior of blood is studied for both transient and steady states of flow. Additionally, flow parameters are compared for steady and transient boundary conditions considering blood as non-Newtonian fluid. The study shows that the highest wall shear stress (WSS), velocity and pressure are found in artery having stenosis in all the three branches of LCA. The use of Newtonian blood model is a good approximation for steady as well as transient blood flow boundary conditions if shear rate is above 100 s-1. However, the assumption of steady blood flow results in underestimating the values of flow parameters such as wall shear stress, pressure and velocity.  相似文献   

12.
The development of synthetic materials, textured polymers and metals and their increasing use in medicine make research of biomaterials' hemocompatibility very relevant. Problems arise from the polymorphism and diversity of the different materials, the static and dynamic test models and the patients' individual biologic factors. First, methods, models, tests as well as preanalytical factors have to be standardized according to the current knowledge in medicine laid down in the ISO 10993 part 4. The routine controls used in clinical chemistry and hematology have to be performed. Information about normal ranges (mean value, standard deviation, 95% confidence interval) should be provided. Tests have to be performed within a minimal delay of usually 2 h since some properties of blood change rapidly following collection. Various conditions (depending on the wall shear rate) were simulated within the centrifugation system and a Chandler system. Qualities and aspects of hemocompatibility such as platelet activation, oxidative burst, hemolysis, fibrinolysis, fibrin formation, generation of thrombin, contact activation, and complement activation were analysed and the results were entered non-dimensionally into a non-dimensional score system, where 0 points stand for the best and 65 points for the worst evaluation. We found a good correlation between the total score and contact activation, thrombin generation and leukocyte activation in a low shear stress system and a good correlation between the total score and thrombin generation, hemolysis and platelet activation in the high shear stress system. Further on the effect of additives and sterilization procedures can be measured. The concepts presented underline the relevance/importance of an efficient diagnostic approach to hemocompatibility that takes account of clinical and socio-economic concerns.  相似文献   

13.
Investigation of platelet margination phenomena at elevated shear stress   总被引:1,自引:0,他引:1  
Zhao R  Kameneva MV  Antaki JF 《Biorheology》2007,44(3):161-177
Thrombosis is a common complication following the surgical implantation of blood contacting artificial organs. Platelet transport, which is an important process of thrombosis and strongly modulated by flow dynamics, has not been investigated under the shear stress level associated with these devices, which may range from tens to several hundred Pascal.The current research investigated platelet transport within blood under supra-physiological shear stress conditions through a micro flow visualization approach. Images of platelet-sized fluorescent particles in the blood flow were recorded within microchannels (2 cm x 100 microm x 100 microm). The results successfully demonstrated the occurrence of platelet-sized particle margination under shear stresses up to 193 Pa, revealing a platelet near-wall excess up to 8.7 near the wall (within 15 microm) at the highest shear stress. The concentration of red blood cells was found to influence the stream-wise development of platelet margination which was clearly observed in the 20% Ht sample but not the 40% Ht sample. Shear stress had a less dramatic effect on the margination phenomenon than did hematocrit. The results imply that cell-cell collision is an important factor for platelet transport under supra-physiologic shear stress conditions. It is anticipated that these results will contribute to the future design and optimization of artificial organs.  相似文献   

14.
15.
Pulsatile flow was studied in physiologically realistic models of a normal and a moderately stenosed (30% diameter reduction) human carotid bifurcation. Time-resolved velocity measurements were made using magnetic resonance imaging, from which wall shear stress (WSS) vectors were calculated. Velocity measurements in the inflow and outflow regions were also used as boundary conditions for a computational fluid dynamics (CFD) model. Experimental flow patterns and derived WSS vectors were compared qualitatively with the corresponding CFD predictions. In the stenosed phantom, flow in the bulb region of the "internal carotid artery" was concentrated along the outer wall, with a region of low and recirculating flow near the inner wall. In the normal phantom, the converse was found, with a low flow region near the outer wall of the bulb. Time-averaged WSS and oscillatory shear index were also markedly different for the two phantoms.  相似文献   

16.
The study of platelet behavior in real-time under controlled shear stress offers insights into the underlying mechanisms of many vascular diseases and enables evaluation of platelet-focused therapeutics. The two most common methods used to study platelet behavior at the vessel wall under uniform shear flow are parallel plate flow chambers and cone-plate viscometers. Typically, these methods are difficult to use, lack experimental flexibility, provide low data content, are low in throughput, and require large reagent volumes. Here, we report a well plate microfluidic (WPM)-based system that offers high throughput, low reagent consumption, and high experimental flexibility in an easy to use well plate format. The system consists of well plates with an integrated array of microfluidic channels, a pneumatic interface, an automated microscope, and software. This WPM system was used to investigate dynamic platelet behavior under shear stress. Multiple channel designs are presented and tested for shear loads with whole blood to determine their applicability to study thrombus formation. Normal physiological shear (0.1-20 dyn/cm(2) ) and pathological shear (20-200 dyn/cm(2) ) devices were used to study platelet behavior in vitro under various shear, matrix coating, and monolayer conditions. The high physiological relevance, low blood consumption, and increased throughput create a valuable technique available to vascular biology researchers. The approach also has extensibility to other research areas including inflammation, cancer biology, and developmental/stem cell research.  相似文献   

17.
An implantable artificial kidney using a hemofilter constructed from an array of silicon membranes to provide ultrafiltration requires a suitable blood flow path to ensure stable operation in vivo. Two types of flow paths distributing blood to the array of membranes were evaluated: parallel and serpentine. Computational fluid dynamics (CFD) simulations were used to guide the development of the blood flow paths. Pressure data from animal tests were used to obtain pulsatile flow conditions imposed in the transient simulations. A key consideration for stable operation in vivo is limiting platelet stress accumulation to avoid platelet activation and thrombus formation. Platelet stress exposure was evaluated by CFD particle tracking methods through the devices to provide distributions of platelet stress accumulation. The distributions of stress accumulation over the duration of a platelet lifetime for each device revealed that stress accumulation for the serpentine flow path exceeded levels expected to cause platelet activation while the accumulated stress for the parallel flow path was below expected activation levels.  相似文献   

18.
Fluid shear stress has been known to activate platelet reaction such as aggregation, but the exact mechanism of shear-induced platelet aggregation (SIPA) has not been fully understood. Calpain, an intracellular calcium-activated cysteine protease, is abundant in platelets and is considered to be activated and involved in the proteolytic processes during platelet activation. A possible activation of calpain in SIPA was investigated, employing a newly developed aggregometer and specific monoclonal antibodies to detect activation of calpain. When a shear stress gradient varying between 6 and 108 dyn/cm2 was applied to platelets, activation of μ-calpain was observed only in high-shear-stressed platelets, resulting in the proteolysis of talin. At 1 min after the onset of constant high shear stress of 108 dyn/cm2, μ-calpain activation and proteolysis of talin were detected and increased in a time-dependent manner. Constant shear stress more than 50 dyn/cm2, applied for 5 min, caused μ-calpain activation and proteolysis of talin, which were increased in a shear-force-dependent manner. Calpeptin, a calpain-specific peptide antagonist, caused the complete inhibition of both μ-calpain activation and proteolysis of talin, while SIPA profiles with calpeptin showed almost no change compared to those without calpeptin. These results suggest the possibility of calpain involvement in late phases of shear-induced platelet activation such as cytoskeletal reorganization. J. Cell. Biochem. 66:54–64, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

19.
20.
Aortic arch aneurysm is a complex pathology which requires coverage of one or more aortic arch vessels. In this study we explore the hemodynamic behavior of the aortic arch in aneurysmatic and treated cases with three currently available treatment approaches: Surgery Graft, hybrid Stent-Graft and chimney Stent Graft. The analysis included four models of the time-dependent fluid domains of aneurysmatic arch and of the surgery, hybrid and chimney endovascular techniques. Dimensions of the models are based on typical anatomy, and boundary conditions are based on typical physiological flow.The simulations used computational fluid dynamics (CFD) methods to delineate the time-dependent flow dynamics in the four geometric models.Results of velocity vectors, flow patterns, blood pressure and wall shear stress distributions are presented.The results delineate disturbed and recirculating flow in the aortic arch aneurysm accompanied with low wall shear stress and velocities, compared to a uniformly directed flow and nominal wall shear stress (WSS) in the model of Surgery graft. Out of the two endograft procedures, the hybrid procedure clearly exhibits better hemodynamic performances over the chimney model, with lower WSS, lower pressure drop and less disturbed and vortical flow regions. Although the chimney procedure requires less manufacturing time and cost, it is associated with higher risk rates, and therefore, it is recommended only for emergency cases. This study may shed light on the hemodynamic factors for these complications and provide insight into ways to improve the procedure.  相似文献   