首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Supercoiled and relaxed DNA were resolved electrophoretically in the presence of 0.5 micrograms/ml ethidium bromide. Under these conditions the Gaussian distributions of topological isomers of both supercoiled and relaxed DNA migrated as discrete bands. The separation of these DNAs was optimized by varying the concentration of electrode buffer. Electrophoresis in the presence of 160 mM Tris-acetate, pH 8.3, 4 mM EDTA resulted in a 20-fold increase in the separation of relaxed and supercoiled DNA relative to electrophoresis in 40 mM Tris-acetate, pH 8.3, 1 mM EDTA.  相似文献   

2.
Capillary zone electrophoresis was optimized to quantitatively determine codeine and paracetamol via central composite factorial design. Critical parameters (concentration, buffer, pH, voltage) assessed effects on resolution, analysis time and efficiencies. Optimum separation conditions were achieved using phosphate buffer 20 mM (pH 6.8) and voltage (15 kV). The optimized procedure easily determined codeine and paracetamol with separation in less than 3 min. Calibration curves (R > 0.999) were prepared, with LODs of 13.5 and 340 ng mL(-1) for codeine and paracetamol, respectively, and a good R.S.D.% (<3%). This method was applied to determine codeine and paracetamol in pharmaceutical formulations; recoveries coincided with stated contents.  相似文献   

3.
A capillary zone electrophoresis (CZE) method, with UV detection and in the presence of dimethyl-beta-CD, was optimized by means of an experimental design for the separation and the simultaneous quantitation of ephedrine, pseudoephedrine, norephedrine (phenylpropanolamine) and norpseudoephedrine (cathine) in urine without any extraction. In this application, the optimization of the analytical conditions with an experimental design was preferred to a univariate study. Therefore, a central composite design was used and the following factors were investigated and varied simultaneously: buffer concentration, buffer pH and dimethyl-beta-CD concentration. In order to evaluate the influence of each experimental parameter on the analytical separation, the resolutions between the four compounds, as well as the separation time and generated current were observed and established as responses of the experimental design. A model was obtained for each response by linear multiple regression of a second-degree mathematical expression. After acceptance of the mathematical models, the most favorable conditions were determined by maximizing the resolutions between the four compounds and by setting the other responses at threshold values. Successful results were obtained with a 260 mM Tris-phosphate buffer at pH 3.5 in the presence of 13.3 mM dimethyl-beta-CD at 25 degrees C and with an applied voltage of 30 kV. Under these optimized conditions, a baseline separation of the four compounds was achieved in less than 6 min. The method was validated in terms of precision, linearity, accuracy and successfully applied for the determination of these compounds in urine samples without any extraction as well as in nutritional supplements.  相似文献   

4.
This work aimed to develop a chiral separation method of ketoconazole enantiomers using electrokinetic chromatography. The separation was achieved using heptakis (2, 3, 6‐tri‐O‐methyl)‐β‐cyclodextrin (TMβCD), a commonly used chiral selector (CS), as it is relatively inexpensive and has a low UV absorbance in addition to an anionic surfactant, sodium dodecyl sulfate (SDS). The influence of TMβCD concentration, phosphate buffer concentration, SDS concentration, buffer pH, and applied voltage were investigated. The optimum conditions for chiral separation of ketoconazole was achieved using 10 mM phosphate buffer at pH 2.5 containing 20 mM TMβCD, 5 mM SDS, and 1.0% (v/v) methanol with an applied voltage of 25 kV at 25 °C with a 5‐s injection time (hydrodynamic injection). The four ketoconazole stereoisomers were successfully resolved for the first time within 17 min (total analysis time was 28 min including capillary conditioning). The migration time precision of this method was examined to give repeatability and reproducibility with RSDs ≤5.80% (n =3) and RSDs ≤8.88% (n =9), respectively. Chirality 27:223–227, 2015. © 2014 Wiley Periodicals, Inc.  相似文献   

5.
A non-competitive immunoassay based on micellar electrokinetic capillary chromatography (MECC) with laser-induced fluorescence (LIF) detection has been developed for the determination of alpha-fetoprotein (AFP). The anti-AFP antibody was labeled with fluorescein isothiocyanate (FITC) and the product was used as a fluorescent tracer, then AFP was mixed with the labeled antibody. After incubation, the immune AFP-antibody complex was separated from labeled free antibody by MECC. The parameters affecting separation such as the concentration of sodium dodecyl sulfate (SDS), the buffer pH and separation voltage were investigated and the following conditions were selected: 20 mM tetraborate containing 100 mM SDS at pH 9.50, and 20 kV separation voltage. The detection limit of this assay was 0.1 ng/ml with a linear range spanning two orders of magnitude. This method was applied to determine AFP in human serum.  相似文献   

6.
The stability of a cationic peroxidase isolated and purified from a cell suspension of Vaccinium myrtillus, microencapsulated in reverse micelles of sodium dioctylsulfosuccinate (AOT) was evaluated. By using a central composite design (CCD), some relevant parameters for the enzymatic activity, such as surfactant and water concentration, pH and buffer molarity, were analysed. The response surface curves showed that 50 mM AOT, 500 mM water, 80 mM buffer and pH 7.6 were the best conditions for enzyme stability. The effect of carbohydrates and polyols on enzyme stability was also evaluated. At 20 mM, carbohydrates like arabinose, and trehalose increased the enzymatic stability by a factor of 4.4 and 2.3, respectively, but melezitose had no effect. From the three polyols tested, inositol and sorbitol increased the peroxidase stability by a factor of 3.8 and 1.8, respectively, while mannitol had no effect.  相似文献   

7.
The stability of a cationic peroxidase isolated and purified from a cell suspension of Vaccinium myrtillus , microencapsulated in reverse micelles of sodium dioctylsulfosuccinate (AOT) was evaluated. By using a central composite design (CCD), some relevant parameters for the enzymatic activity, such as surfactant and water concentration, pH and buffer molarity, were analysed. The response surface curves showed that 50 mM AOT, 500 mM water, 80 mM buffer and pH 7.6 were the best conditions for enzyme stability. The effect of carbohydrates and polyols on enzyme stability was also evaluated. At 20 mM, carbohydrates like arabinose, and trehalose increased the enzymatic stability by a factor of 4.4 and 2.3, respectively, but melezitose had no effect. From the three polyols tested, inositol and sorbitol increased the peroxidase stability by a factor of 3.8 and 1.8, respectively, while mannitol had no effect.  相似文献   

8.
Purified rat ceruloplasmin is extraordinarily unstable in storage at –70 °C. In a 20 mM phosphate buffer, pH 7.0, the ferroxidase and amine oxidase of ceruloplasmin are over 90% inactivated within two weeks. Holoceruloplasmin stored for three months in a 20 mM barbital buffer (or acetate buffer), pH 7.0 (or pH 5.5) was transformed into an apo-protein and amine (o-dianisidine) oxidase of ceruloplasmin was inactivated by 50–55%. The patterns of ferroxidase activity loss were similar to those of amine oxidase activity loss. On the contrary, when holoceruloplasmin was mixed with rat serum albumin, transformation into apoceruloplasmin was significantly prevented in a 20 mM barbital buffer, pH 7.0 (or 20 mM acetate buffer, pH 5.5). Consequently, ferroxidase and amine oxidase activities of ceruloplasmin were not inactivated and the immunochemical reactivity was not changed. These results can be applied for laboratorial and clinical purposes.  相似文献   

9.
Wang R  Jia ZP  Fan JJ  Hu XL  Li YM  Chen LR  Xie JW  Zhang Q 《Chirality》2004,16(1):45-49
A capillary electrophoresis method was developed to separate the enantiomers of cefoperazone. Different cyclodextrins, including alpha-cyclodextrin (alpha-CD), beta-cyclodextrin (beta-CD), gamma-cyclodextrin (gamma-CD), 2-hydroxypropyl-beta-cyclodextrin (HP-beta-CD), and methyl-beta-cyclodextrin (Me-beta-CD), were tested as chiral additives in the running buffer. The effect of various parameters on enantioseparation such as concentration of NaH(2)PO(4), buffer pH, and CD concentration was also studied. The cefoperazone enantiomers were baseline separated under conditions of 0.04 mmol/L beta-CD, 75 mmol/L NaH(2)PO(4) buffer at pH 4.0. A fused silica capillary (40 cm effective length x 75 microm ID) was used. The applied voltage and capillary temperature were 20 kV and 25 degrees C, respectively. Under these conditions, linear calibration curves were obtained in the 5-500 microg/ml range using UV detection at 280 nm. The limit of detection for both isomers was 0.1 microg/ml. The method was used for the analysis of different pharmaceutical preparations (dose) and biological samples containing cefoperazone.  相似文献   

10.
Much attention has been paid to chiral ionic liquids (ILs) in analytical chemistry, especially its application in capillary electrophoresis (CE) enantioseparation. However, the investigation of chiral ionic liquids synergistic systems based on antibiotic chiral selectors has been reported in only one article. In this work, a novel chiral ionic liquid, tetramethylammonium‐L‐hydroxyproline (TMA‐L‐Hyp), was applied for the first time in CE chiral separation to evaluate its potential synergistic effect with clindamycin phosphate (CP) as the chiral selector. As observed, significantly improved separation was obtained in this TMA‐L‐Hyp/CP synergistic system compared to TMA‐L‐Hyp or a CP single system. Several primary factors that might influence the separation were investigated, including CP concentration, TMA‐L‐Hyp concentration, buffer pH, types and concentrations of organic modifier, applied voltage, and capillary temperature. The best results were obtained with a 40 mM borax buffer (pH 7.6) containing 30 mM TMA‐L‐Hyp, 80 mM CP, and 20% (v/v) methanol, while the applied voltage and temperature were set at 20 kV and 20°C, respectively. Chirality 27:598–604, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

11.
Guihen E  Hogan AM  Glennon JD 《Chirality》2009,21(2):292-298
In this research, a capillary electrophoretic method for the fast enantiomeric resolution of (R,S)-naproxen was investigated. Method development involved variation of applied potential, buffer concentration, buffer pH, and cyclodextrin concentration. The optimum electrophoretic separation conditions were 110 mM sodium acetate run buffer (pH 6.0), 30 mM methyl-beta-cyclodextrin, 20% (v/v) acetonitrile, 25 degrees C. The total length of capillary was 48 cm, (50 microm I.D.) with ultra violet (UV) detection at 232 nm. Using these conditions, the number of theoretical plates was close to one million (896,000/m). The possibility of achieving a fast chiral separation of (R,S)-naproxen on a microchip of 2.5 cm in length was investigated. Complete enantiomeric resolution of naproxen was achieved in less than 1 min, on this microchip platform, with linear imaging UV detection. This system had the advantage of real-time separation monitoring, so that enantiomeric resolution could be visually observed, and high-speed chiral analysis was realized. The microchip electrophoresis (MCE) separation was compared with the capillary electrophoresis (CE) separation with regards to speed, efficiency, separation platform, and precision. This work highlights the potential of CE and MCE in future chiral separations.  相似文献   

12.
Michal Dou&#x;a 《Chirality》2019,31(3):202-210
A sensitive chiral high performance liquid chromatography (HPLC) method for the determination of aliphatic primary amino alcohol isomers with o‐phthaldialdehyde/mercaptoethanol precolumn derivatization has been developed and validated. Seven chiral columns were tested in a reversed phase mode. Excellent enantioseparation with the resolution more than 2.0 was achieved on Chiralcel OJ‐3R. The effect of various chromatographic conditions including column temperature, acetonitrile content in the mobile phase, buffer pH, buffer concentration, and buffer type in the mobile phase on the retention and the selectivity was investigated. The final mobile phase consisted of binary mixture of 20mM ammonium formate solution with acetonitrile (75:25; v/v). The analyses were performed at mobile phase flow rate of 1.0 mL/min and the column temperature of 40°C. The fluorescence detection was performed at excitation wavelength of 345 nm and emission wavelength of 450 nm. The developed method was fully validated in terms of linearity, sensitivity, accuracy, precision, intermediate precision, and selectivity according to International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use guidelines using internal normalization procedure. The proposed chiral method was proved to be highly sensitive, simple, and rapid and was successfully applied to the determination of D‐Valinol content in commercially available samples of L‐Valinol.  相似文献   

13.
Optimal assay conditions for analyses of the catalytic subunit activity of the cyclic AMP-dependent protein kinase using a well-defined, commercially available synthetic peptide as the phosphate acceptor are defined. Activity of purified catalytic subunit toward the synthetic peptide Leu-Arg-Arg-Ala-Ser-Leu-Gly (PK-1; Kemptide) was 1.5- to 45-fold greater than activity toward other commonly used substrates such as histone fractions, casein, and protamine. The effects of buffer, pH, Mg2+, and protein kinase concentration on activity toward PK-1 were investigated. The optimal assay conditions determined were as follows: 20 mM Hepes or phosphate buffer, pH 7.5, 100 microM PK-1, 100 microM [gamma-32P]ATP, 3 mM MgCl2, 12 mM KCl, and 20-200 ng of catalytic subunit assayed at 30 degrees C. Since PK-1 is the only commercially available, well-defined substrate for this enzyme, adaption of the proposed standard assay conditions for the analyses of purified catalytic subunit activity will permit direct comparison of kinetic parameters and purity of enzyme preparations from multiple preparations.  相似文献   

14.
The immobilized metal affinity membrane (IMAM) with modified regeneration cellulose was employed for purification of penicillin G acylase (PGA). For studying PGA adsorption capacity on the IMAM, factors such as chelator surface density, chelating metal, loading temperature, pH, NaCl concentration and elution solutions were investigated. The optimal loading conditions were found at 4 degrees C, 0.5 M NaCl, 32.04 micromol Cu(2+) per disk with 10 mM sodium phosphate buffer, pH 8.5, whereas elution conditions were: 1 M NH(4)Cl with 10 mM sodium phosphate buffer, pH 6.8. By applying these chromatographic conditions to the flow experiments in a cartridge, a 9.11-fold purification in specific activity with 90.25% recovery for PGA purification was obtained. Meanwhile, more than eight-times reusability of the membrane was achieved with the EDTA regeneration solutions.  相似文献   

15.
An efficient and reliable micellar electrokinetic capillary chromatography (MEKC) method has been developed for the simultaneous determination of isoniazid (ISO) and pyridoxine hydrochloride (PYR) in pharmaceutical formulations. A chemometric two level full factorial design approach was used to search for the optimum conditions of separation. Three parameters were selected for this study: the buffer pH, the buffer concentration and sodium dodecyl sulphate (SDS) concentrations. Resolution, peak symmetry and analysis time were established as response. The two analytes were separated within 6 min with the optimized conditions: 50 mM borate buffer, 25 mM SDS pH 7.8, 35 degrees C, at 50 mbar 4s injection and 30 kV by using a fused silica capillary (72 cm effective length, 50 microm i.d.). The detection wavelength was set to 205 nm. Meloxicam was used as internal standard. The method was validated with respect to stability, linearity range, limit of quantitation and detection, precision, accuracy, specificity and robustness. The detection limits of the method were 1.0 microg mL(-1) for ISO and 0.40 microg mL(-1) for PYR and the method was linear at least in the range of 3.0-100 microg mL(-1) for ISO and 1.0-100 microg mL(-1) for PYR with excellent correlation coefficients (0.9995 for ISO and 0.9998 for PYR). Relative standard deviations (R.S.D.s) of the described method ranged between 0.54 and 2.27% for intra-day precision and between 0.65 and 2.69% for inter-day precision. The developed method was applied to the tablet form of ISO and PYR-containing the pharmaceutical preparations and the data were compared with obtained from the standard addition method. No statistically significant difference was found.  相似文献   

16.
A potentiometric enzyme electrode for the direct measurement of organophosphate (OP) nerve agents was developed. The basic element of this enzyme electrode was a pH electrode modified with an immobilized organophosphorus hydrolase (OPH) layer formed by cross-linking OPH with bovine serum albumin (BSA) and glutaradehyde. OPH catalyses the hydrolysis of organophosphorus pesticides to release protons, the concentration of which is proportional to the amount of hydrolysed substrate. The sensor signal and response time was optimized with respect to the buffer pH, ionic concentration of buffer, temperature, and units of OPH immobilized using paraoxon as substrate. The best sensitivity and response time were obtained using a sensor constructed with 500 IU of OPH and operating in pH 8.5, 1 mM HEPES buffer. Using these conditions, the biosensor was used to measure as low as 2 microM of paraoxon, ethyl parathion, methyl parathion and diazinon. The biosensor was completely stable for at least one month when stored in pH 8.5, 1 mM HEPES + 100 mM NaCl buffer at 4 degrees C.  相似文献   

17.
Microband glucose biosensors were fabricated by screen-printing a water-based carbon ink formulation containing cobalt phthalocyanine redox mediator and glucose oxidase (GOD) enzyme, then insulating and sectioning through the thick (20mum) film to expose a 3mm-long working electrode edge. The performance of these biosensors for glucose analysis was investigated at 25 degrees C. Voltammetry in glucose-containing buffer solutions established that an operating potential of +0.4V vs. Ag/AgCl was suitable for analysis under both stirring and quiescent conditions. The influence of pH on biosensor performance was established and an operational pH of 8.0 was selected. Steady-state responses were obtained under quiescent conditions, suggesting a mixed mechanism predominated by radial diffusion, indicative of microelectrode behaviour. Calibration studies obtained with these biosensors showed steady-state currents that were linearly dependent on glucose concentration from the limit of detection (0.27mM) up to 2.0mM, with a precision for replicate biosensors of 6.2-10.7%. When applied to the determination of glucose in human serum, the concentration compared favourably to that determined by a spectroscopic method. These results have demonstrated a simple means of fabricating biosensors for glucose measurement and determination in situations where low-current real-time monitoring under quiescent conditions would be desirable.  相似文献   

18.
Many liquid formulations for monoclonal antibodies (MAbs) require the final ultrafiltration/diafiltration step to operate at high protein concentrations, often at or above 100 g/L. When operating under these conditions, the excipient concentrations and pH of the final diafiltered retentate are frequently not equal to the corresponding excipient concentrations and pH of the diafiltration buffer. A model based on the Poisson-Boltzmann equation combined with volume exclusion was extended to predict both pH and excipient concentrations in the retentate for a given diafiltration buffer. This model was successfully applied to identify the diafiltration buffer composition required to achieve the desired pre-formulated bulk drug substance (retentate) conditions. Predictions were in good agreement with the experimental results, and reduced the number of experimental iterations needed to define the diafiltration buffer composition. Additionally, the predictive model was applied in a sensitivity analysis across ranges of protein charge, protein concentration, and diafiltration buffer pH and excipient concentration. This sensitivity analysis can facilitate the design of experiments for robustness testing, and allow for generalized predictions across classes of molecules such as MAbs.  相似文献   

19.
The use of micellar electrokinetic chromatography for the determination of lormetazepam and its metabolite, lorazepam, in serum samples at a concentration range of therapeutic interest was investigated. The separation was carried out at 30 degrees C and 25 kV, using a 15 mM borate-phosphate buffer (pH 8) with 30 mM sodium dodecyl sulfate as the separation electrolyte and 15% methanol as organic modifier. The analyses were carried out in 20 min under these conditions. Detection limits of 0.5 mg l(-1) were achieved for both benzodiazepines in serum. This method was employed for the quantitative resolution of both drugs (at different concentration ratios) in serum with very good recoveries.  相似文献   

20.
Properties of the membrane and soluble forms of somatic angiotensin-converting enzyme (ACE) were studied in the system of hydrated reversed micelles of aerosol OT (AOT) in octane. The membrane enzyme with a hydrophobic peptide anchor was more sensitive to anions and to changes in pH and composition of the medium than the soluble enzyme without anchor. The activity of both forms of the enzyme in the reversed micelles significantly depended on the molarity of the buffer added to the medium (Mes-Tris-buffer, 50 mM NaCl). The maximum activity of the soluble ACE was recorded at buffer concentration of 20-50 mM, whereas the membrane enzyme was most active at 2-10 mM buffer. At buffer concentrations above 20 mM, the rate of hydrolysis of the substrate furylacryloyl-L-phenylalanyl-glycylglycine by both ACE forms was maximal at pH 7.5 both in the reversed micelles and in aqueous solutions. However, at lower concentrations of the buffer (2-10 mM), the membrane enzyme had activity optimum at pH 5.5. Therefore, it is suggested that two conformers of the membrane ACE with differing pH optima for activity and limiting values of catalytic constants should exist in the reversed micelle system with various medium compositions. The data suggest that the activity of the membrane-bound somatic ACE can be regulated by changes in the microenvironment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏