首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In order to enhance frictional wear resistance and thermal fatigue resistance of brake drums, two kinds of biomimetic coupling materials are prepared by laser surface melting and laser coating technology respectively. These materials are all compounded by base metal and biomimetic coupling units, and have different coupling characteristics, such as the variation of the unit shape, different microstructures and hardness, different chemical compositions of units. The frictional wear resistance and thermal fatigue resistance of biomimetic coupling materials and gray cast iron used for brake drum are compared. The results indicate that frictional wear resistance and thermal fatigue resistance of biomimetic coupling sample is better than that of untreated sample, and among the biomimetic samples, laser coating treated sample has superior resistance to wear and thermal fatigue comparing with laser melting treated sample.  相似文献   

2.
<正> Biomimetic surface is an effective ways to promote the performance grade and applied range of materials without alteringtheir substrate.Many improved properties such as resisting fatigue,enduring wear,etc,have been achieved by applyingbiomimetic morphology or structure to some engineering material surfaces.In this paper,aiming to reveal the relationshipbetween thermal cracking behavior and mechanical properties of engineering materials with biomimetic surface,biomimeticspecimens were fabricated using laser technique by imitating the heterogeneous structure on the surface of plant leaves.Theeffect of thermal fatigue cycling on the tensile properties of H13 die steel specimens with different surfaces (several types ofbiomimetic surfaces and a smooth surface) was compared and investigated.As a result,due to the coupling effects of themorphological features on the surface and the microstructure characteristics within unit zone,these specimens with biomimeticsurface exhibit remarkably enhanced Ultimate Tensile Strength (UTS) and 0.2% Yield Strength (YS) compared with referencespecimens while corresponding ductility remains largely unaffected even heightened,whether the thermal fatigue loads or not.The relative mechanisms leading to these improvements have been discussed.  相似文献   

3.
Erosion-Resistant Surfaces Inspired by Tamarisk   总被引:2,自引:0,他引:2  
Tamarisk, a plant that thrives in arid and semi-arid regions, has adapted to blustery conditions by evolving extremely ef- fective and robust anti-erosion surface patterns. However, the details of these unique properties and their structural basis are still unexplored. In this paper, we demonstrate that the tamarisk surface only suffers minor scratches under wind-sand mixture erosion. The results show that the anti-erosion property of bionic sample, inspired by tamarisk surface with different surface morphologies, can be attributed to the flow rotating in the grooves that reduces the particle impact speed. Furthermore, the simulation and experiment on the erosion wear behavior of the bionic samples and bionic centrifugal fan blades show that the bionic surface with V-type groove exhibits the best erosion resistance. The bionic surface on centrifugal fan blades with opti- mum parameters can effectively improve anti-erosion property by 28.97%. This paper show more opportunities for bionic application in improving the anti-erosion performance of moving parts that work under dirt and sand particle environment, such as helicopter rotor blades, airplane propellers, rocket motor nozzles, and pipes that regularly wear out from erosion.  相似文献   

4.
Despite the fundamental value of wear simulation studies to assess wear resistance of total joint replacements, neither specialised simulators nor established external conditions are available for the human ankle joint. The aim of the present study was to verify the suitability of a knee wear simulator to assess wear rates in ankle prostheses, and to report preliminary this rate for a novel three-component total ankle replacement design. Four intact 'small' size specimens of the Box ankle were analysed in a four-station knee wear simulator. Special component-to-actuator holders were manufactured and starting spatial alignment of the three-components was sought. Consistent load and motion cycles representing conditions at the ankle joint replaced exactly with the prosthesis design under analysis were taken from a corresponding mechanical model of the stance phase of walking. The weight loss for the three specimens, after two million cycles, was 32.68, 14.78, and 62.28mg which correspond to a linear penetration of 0.018, 0.008, and 0.034mm per million-cycle, respectively for the specimens #1, #2, and #3. The knee wear simulator was able to reproduce load-motion patterns typical of a replaced ankle. Motion of the meniscal bearing in between the tibial and talar components was smooth, this component remaining in place and in complete congruence with the metal components throughout the test.  相似文献   

5.
Mechanical surface treatments have a long history in traditional engineering disciplines, such as the automotive or aerospace industries. Today, they are widely applied to metal components to increase the mechanical performance of these. However, their application in the medical field is rather rare. The present study aims to compare the potential of relevant mechanical surface treatments on the high cycle fatigue (R = 0.1 for a maximum of 10 million cycles) performance of a Ti6Al4V standard alloy for orthopedic, spinal, dental and trauma surgical implants: shot peening, deep rolling, ultrasonic shot peening and laser shock peening. Hour-glass shaped Ti6Al4V specimens were treated and analyzed with regard to the material’s microstructure, microhardness, residual stress depth profiles and the mechanical behavior during fatigue testing. All treatments introduced substantial compressive residual stresses and exhibited considerable potential for increasing fatigue performance from 10% to 17.2% after laser shock peening compared to non-treated samples. It is assumed that final mechanical surface treatments may also increase fretting wear resistance in the modular connection of total hip and knee replacements.  相似文献   

6.
Energy consumption and tribological properties could be improved by proper design of surface texture in friction. However, some literature focused on investigating their performance under high temperature. In the study, different groove surface textures were fabricated on steels by a laser machine, and their tribological behaviors were experimentally studied with the employment of the friction and wear tester under distinct high temperature and other working conditions. The friction coefficient was recorded, and wear performance were characterized by double light interference microscope, scanning electron microscope (SEM) and x-ray energy dispersive spectrometry (EDS). Then, the performances of energy consumptions were carefully estimated. Results showed that friction coefficient, wear, and energy consumption could almost all be reduced by most textures under high temperature conditions, but to a different extent which depends on the experimental conditions and texture parameters. The main improvement mechanisms were analyzed, such as the hardness change, wear debris storage, thermal stress release and friction induced temperature reduction by the textures. Finally, a scattergram of the relatively reduced ratio of the energy consumption was drawn for different surface textures under four distinctive experimental conditions to illustrate the comprehensive energy consumption improving ability of textures, which was of benefit for the application of texture design.  相似文献   

7.
A microclimatic layer of the green façade is proven to have specific temperature and flow conditions on the building envelope. Lower temperatures and wind velocities, and higher relative humidity in the microclimatic layer are the characteristics of vertical greenery systems, which cause lower energy consumption for the cooling and heating of buildings. Despite innovative architectural solutions, there are some drawbacks to applying vertical greenery on building envelopes. In this study, a bionic façade that mimics the positive effects and eliminates the disadvantages of green façades is presented. The bionic façade consists of bionic leaves, which are made of photovoltaic cells and evaporative matrices. A real scale experiment was carried out in the summer to evaluate the potential of the cooling efficiency of the microclimatic layer and a new photovoltaic cooling technique. The results show a good agreement of the thermal performance between the bionic and the green façade and up to 20.8 K lower surface temperatures of photovoltaic cells, which increase the daily electricity yield by 6.6%.  相似文献   

8.
Military operations in tropical environments have imposed a significant challenge to the Australian Defence Forces (ADF). The hot and humid conditions are known to cause debilitating effects on soldiers deployed to northern regions of Australia, with the consequence that the effectiveness and efficiency of operations are severely compromised. While the adverse effects of thermal stress on soldiers' physiological capability are well established, this has not been confirmed for cognitive performance. A select range of psychometric tests were administered and functional brain electrical activity imaging was performed to investigate the impact of thermal stress on cognitive performance. The brain electrical activity of subjects was measured while undertaking a range of cognitive tasks. Steady State Probe Topography (SSPT), a novel brain imaging technology, was employed to monitor the changes in regional brain activity and neural processing speed of subjects under thermal stress. The psychometric test batteries included the following tasks; Rey Auditory Verbal Learning Test; Inspection Time; Digit Span test; a spatial working memory task; and the AX-continuous performance task. These tasks measure a range of cognitive processes including attention, memory, verbal learning, information processing and concentration. The functional brain imaging provided topographical information, which showed changes in electrical activity in response to thermal stress during cognitive performance. These changes in brain electrical activity and neural speed induced by thermal stress may help to identify the type of cognitive functions that are likely to be impaired under operational conditions. Results indicated that subjects experienced increasing cardiovascular strain through thermally neutral to thermally straining conditions. The results from the psychometric test battery showed some promising effects given the small sample size including deficits in working memory, in information retention and in information processing. There was also marked differences in the electrical responses of the brain when subjects were thermally strained. The Steady-State Visual Evoked Potential recordings showed an increase in amplitude and a decrease in latency, suggesting an increase in the utilisation of neural resources or effort by subjects to maintain the same level of performance as under thermally neutral conditions. The data are suggestive of the high sensitivity of brain imaging techniques with high temporal resolution to identify important decrements in cognitive performance in hostile environments.  相似文献   

9.
Bellucci G  Seedhom BB 《Biorheology》2002,39(1-2):193-199
Although fatigue has been implicated in cartilage failure there are only two studies by the same author, and in both of which cartilage was tested in the direction parallel to the collagen orientation in the surface layer. In the present work articular cartilage was tested also along the perpendicular direction, being the direction in which cartilage possesses lower tensile strength.Specimens were tested under cyclic tensile load. Number of cycles at failure was recorded as well as elongation of the specimen. To date 72 specimens have been tested all from one knee joint.The number of cycles to failure ranged between two and 1.5 million. The surface and deep layers have better fatigue properties whether tested in the parallel or the perpendicular direction, while the middle layer was far weaker. Better fatigue behaviour was observed with specimens tested in parallel than in perpendicular direction to the fibres.  相似文献   

10.
Intracerebral hemorrhage (ICH) is a devastating stroke sub-type with high mortality and morbidity. ICH frequently occurs in subcortical white matter generating hematomas that contain high heme iron levels. In this study, we examined the consequences of iron-induced oxidation (1-100 microM Fe2+ for 30 min. or 50 microM Fe2+ for 1-120 min.) on the activities of two oxidatively sensitive enzymes, creatine kinase (CK) and glutamine synthetase (GS), and on an oxidative stress marker, protein carbonyl formation, in porcine cerebral cortical white and gray matter. In vitro iron oxidation produced time and concentration dependent decreases in both CK [maximum decreases of 49.3+/-1.2% and 44.3+/-4.1% (average +/- SEM, N=3) for white and gray matter, respectively] and GS activities (maximum decreases of 16.9+/-1.7% and 13.2+/-1.0% for white and gray matter, respectively) and increases in protein carbonyl formation. Interestingly, protein carbonyl concentrations were significantly greater (p<0.05) in white vs. gray matter at 100 microM iron (30 min.) and 50 microM iron (120 min.). Additionally, CK and GS activities were lower for white versus gray matter at several time points and iron concentrations. It is our hypothesis that iron induced oxidative stress contributes to the pathogenesis of perihematomal brain injury following ICH.  相似文献   

11.
In this study, iron impregnated activated carbon (FeAC) was synthesized following an oxidation and iron impregnation of activated carbon (AC). Both the AC and FeAC were characterized by pHZPC and FTIR spectroscopy. The removal of Methylene Blue (MB) by AC and FeAC was examined under various experimental conditions. The FeAC showed up to 95% (higher than AC) MB removal in the pH range of 7–10. Although the reaction kinetics was pseudo–second order, the overall rate was controlled by a number of processes such as film diffusion, pore diffusion and intraparticle diffusion. The activation energy values for the MB uptake by AC and FeAC (21.79 and 14.82 kJ/mol, respectively) revealed a physisorption process. In the regeneration study, FeAC has shown consistently ≥ 90% MB removal even up to 10 repeated cycles. The reusable characteristic of the spent FeAC improved the practical use of activated carbon and can be a breakthrough for continuous flow system applications where it can work effectively without any significant reduction in its performance.  相似文献   

12.
We have developed a mixed system, electrochemical-microbiological, that can be used for detoxifying organic compounds present in wastewater. In this system, organic matter oxidation takes place at the anode of an electrochemical reactor while ferric iron reduction takes place at the cathode. We have used a growing culture of Thiobacillus ferrooxidans to regenerate the ferric ions consumed. The culture is used as the catholyte (solution in the cathode compartment) of the system and is therefore permanently subjected to an electric field. We have verified that, under our working conditions, the culture is able to oxidize ferrous ions for long periods of time (up to 15 days) depending on the intensity of the applied current. We have checked the performance of this system in methanol oxidation. Our results show that it decreases the energy cost by 35% when com- pared with the pure electrochemical system traditionally used. Copyright 1999 John Wiley & Sons, Inc.  相似文献   

13.
One possible loosening mechanism of the femoral component in total hip replacement is fatigue cracking of the cement mantle. A computational method capable of simulating this process may therefore be a useful tool in the preclinical evaluation of prospective implants. In this study, we investigated the ability of a computational method to predict fatigue cracking in experimental models of the implanted femur construct. Experimental specimens were fabricated such that cement mantle visualisation was possible throughout the test. Two different implant surface finishes were considered: grit blasted and polished. Loading was applied to represent level gait for two million cycles. Computational (finite element) models were generated to the same geometry as the experimental specimens, with residual stress and porosity simulated in the cement mantle. Cement fatigue and creep were modelled over a simulated two million cycles. For the polished stem surface finish, the predicted fracture locations in the finite element models closely matched those on the experimental specimens, and the recorded stem displacements were also comparable. For the grit blasted stem surface finish, no cement mantle fractures were predicted by the computational method, which was again in agreement with the experimental results. It was concluded that the computational method was capable of predicting cement mantle fracture and subsequent stem displacement for the structure considered.  相似文献   

14.
The clinical success of second-generation metal-on-metal hip replacement and the good tribological performance of alumina ceramic revived an interest in hip articulation as a solution to reduce wear.This study was aimed at characterizing the wear behaviour of new hybrid ceramic-on-metal bearings. In particular, this study investigated the wear behaviour of ceramic-on-metal hip components (three different diameters configurations: 28, 32 and 36 mm), not specifically proposed to be coupled, in order to compare them with ceramic-on-ceramic, which is considered to be the gold standard for wear resistance. For this purpose, the weight loss over a standard wear simulation was monitored. Moreover, scanning electronic microscope observations were used to verify if any carbides removal, for the metallic components, triggered wears debris production promoting abrasive third-body wear.After five million cycles, our results showed significantly greater wear-in ceramic-on-metal compared with ceramic-on-ceramic, and significant greater wear for the 32-mm diameter compared with the 36-mm one. Our findings showed an increase in wear for the proposed hybrid specimens with respect to that of the ceramic-on-ceramic ones confirming that even in the case of ceramic-on-metal bearings, mixing and matching could not prove effective wear behaviour, not even comparable with that of the ceramic-on-ceramic gold standard. Wear patterns and roundness tolerances certainly discourage the coupling of components not specifically intended to be coupled. Unsuitable geometrical conformity could, in fact, result in a poor dynamic behaviour and lead to clinical failure.  相似文献   

15.
The shoulder allows kinematic and muscular changes to facilitate continued task performance during prolonged repetitive work. The purpose of this work was to examine changes during simulated repetitive work in response to a fatigue protocol. Participants performed 20 one-minute work cycles comprised of 4 shoulder centric tasks, a fatigue protocol, followed by 60 additional cycles. The fatigue protocol targeted the anterior deltoid and cycled between static and dynamic actions. EMG was collected from 14 upper extremity and back muscles and three-dimensional motion was captured during each work cycle. Participants completed post-fatigue work despite EMG manifestations of muscle fatigue, reduced flexion strength (by 28%), and increased perceived exertion (∼3 times). Throughout the post-fatigue work cycles, participants maintained performance via kinematic and muscular adaptations, such as reduced glenohumeral flexion and scapular rotation which were task specific and varied throughout the hour of simulated work. By the end of 60 post-fatigue work cycles, signs of fatigue persisted in the anterior deltoid and developed in the middle deltoid, yet perceived exertion and strength returned to pre-fatigue levels. Recovery from fatigue elicits changes in muscle activity and movement patterns that may not be perceived by the worker which has important implications for injury risk.  相似文献   

16.
Multicopper oxidases have been described to have functions in copper tolerance, manganese oxidation, and iron oxidation in a range of bacteria. The putative cytoplasmic membrane multicopper oxidase from Legionella pneumophila was investigated. The mcoL gene was found to be critical for aerobic extracellular growth under either iron-limiting conditions or in the presence of ferrous Fe(II) iron, as a sole source of this essential metal. The mcoL mutants showed minor growth defects when grown in the presence of Fe(III) as the iron source. In contrast, intracellular growth and survival was not affected by the absence of the mcoL gene regardless of available iron concentration. The evidence presented here could indicate a possible role for mcoL in prevention of the toxic effects of ferrous iron during aerobic conditions. However, a function in high-affinity acquisition of iron could also be possible given the inability of the McoL mutants to grow aerobically under iron-limiting conditions.  相似文献   

17.
Three types of rough surface were processed by laser irradiation on the 3Cr2W8V material hot-work die steel surface.The wear experiments with smooth surface and rough surface samples were repeated on the pin-tray wear machine. According to the wear results, we studied the regularity of wear resistance of different rough surface samples. The results indicated that bionic rough surface can improve the wear resistance of the material and the wear resistance can be increased 1 - 2 times, compared with the smooth surface. Also, the wear resistance of the rough surface was affected by laser current and duration of impulse. The bigger the laser current or the impulse duration, the better is the wear resistance. When the distance between the same kind of units which are distributed on the surfaces is changed, the wear resistance changes. The wear resistance of a bionic rough surface on which the grid units were distributed at spacing of 1 mm was the best. And we designed the wear models.  相似文献   

18.
Oxidation of arsenic(III) by the bacterial community of a contaminated sediment (from the Estaque marina, Marseille, France) was studied using microcalorimetry. A low, but reproducible, heat output was detectable during microbial As(III) oxidation. The heat produced was of the same order of magnitude as the heat value calculated from the standard molar enthalpy change for the As(III) oxidation by oxygen. Parameters associated with the biogeochemical cycles of arsenic, iron and carbon were studied in parallel. Amendment with arsenite delayed CO2 production and increased the rate of Fe(II) oxidation in the sediment. These results suggest a correlation between arsenic and iron biogeochemical cycles and mineralization of organic matter.

Supplemental materials are available for this article. Go to the publisher's online edition of Geomicrobiology Journal to view the supplemental file.  相似文献   

19.
We proposed a kind of bionic leaf to simulate the thermal effect of leaf transpiration. The bionic leaf was firstly designed to be composed of a green coating, a water holding layer, a Composite Adsorbent (CS) layer and an adsorption-desorption rate controlling layer. A thermophysical model was established for the bionic leaf, and the dynamic simulation results reveal that the water holding layer is not necessary; a CS of high thermal conductivity should be selected as the CS layer; the adsorp- tion-desorption rate controlling layer could be removed due to the low adsorption-desorption rate of the CS; and when CaC12 mass fraction of the CS reaches 40%; the bionic leaf could simulate the dynamic thermal behavior of the natural leaf. Based on the simulation results, we prepared bionic leaves with different CaC12 content. The thermographies of the bionic leaf and the natural leaf were shot using the Infrared Thermal Imager. The measured average radiative temperature difference between the bionic and natural leaves is less than 1.0 ℃.  相似文献   

20.
The hollow sphere-shaped 24-meric ferritin can store large amounts of iron as a ferrihydrite-like mineral core. In all subunits of homomeric ferritins and in catalytically active subunits of heteromeric ferritins a diiron binding site is found that is commonly addressed as the ferroxidase center (FC). The FC is involved in the catalytic Fe(II) oxidation by the protein; however, structural differences among different ferritins may be linked to different mechanisms of iron oxidation. Non-heme ferritins are generally believed to operate by the so-called substrate FC model in which the FC cycles by filling with Fe(II), oxidizing the iron, and donating labile Fe(III)–O–Fe(III) units to the cavity. In contrast, the heme-containing bacterial ferritin from Escherichia coli has been proposed to carry a stable FC that indirectly catalyzes Fe(II) oxidation by electron transfer from a core that oxidizes Fe(II). Here, we put forth yet another mechanism for the non-heme archaeal 24-meric ferritin from Pyrococcus furiosus in which a stable iron-containing FC acts as a catalytic center for the oxidation of Fe(II), which is subsequently transferred to a core that is not involved in Fe(II)-oxidation catalysis. The proposal is based on optical spectroscopy and steady-state kinetic measurements of iron oxidation and dioxygen consumption by apoferritin and by ferritin preloaded with different amounts of iron. Oxidation of the first 48 Fe(II) added to apoferritin is spectrally and kinetically different from subsequent iron oxidation and this is interpreted to reflect FC building followed by FC-catalyzed core formation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号