首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In a comparison of two commonly used membrane filters for enumerating fecal coliform bacteria it was demonstrated that Seitz type M filters recovered statistically more colonies of bacteria than did Millipore HAWG 047S1 filters from pure cultures of Escherichia coli incubated at 44 °C. The membranes were grown on 0.4 % Teepol agar. On incubation at 37°C no significant discrepancy was found. As a reference method was used pour plating in plate count agar (Difco). It was demonstrated that incubation at 44°C did not per se inhibit propagation of fecal coliforms. Both types of filters examined were sterilized by the manufacturers with ethylene oxide. The discrepancy found can therefore not be due to sterilization procedures.  相似文献   

2.
Influence of Coliform Source on Evaluation of Membrane Filters   总被引:3,自引:3,他引:0       下载免费PDF全文
Four brands of membrane filters were examined for total and fecal coliform recovery performance by two experimental approaches. Using diluted EC broth cultures of water samples, Johns-Manville filters were superior to Sartorius filters for fecal coliform but equivalent for total coliform recovery. Using river water samples, Johns-Manville filters were superior to Sartorius filters for total coliform but equivalent for fecal coliform recovery. No differences were observed between Johns-Manville and Millipore or Millipore and Sartorius filters for total or fecal coliform recoveries using either approach, nor was any difference observed between Millipore and Gelman filters for fecal coliform recovery from river water samples. These results indicate that the source of the coliform bacteria has an important influence on the conclusions of membrane filter evaluation studies.  相似文献   

3.
Autoclave and ethylene oxide-sterilized membrane filters manufactured by Gelman, Millipore, and Sartorius were field tested for their recovery of total coliforms, fecal coliforms, fecal streptococci, and heterotrophs. The data were analyzed by using split-plot analysis of variance and significance tests. Membranes were also tested for pH and toxicity using Escherichia coli. The mean data summaries indicated that Gelman membrane filters generally produced the highest counts during the field studies. Statistical analyses of the March data showed that there were significant differences between membrane filters at 1% level; however, statistical analyses of June data revealed no significant differences except in total coliform recoveries. Toxicity tests at 35 C indicated that Gelman and Millipore autoclaved membrane filters were able to recover 92% of the test organisms. Toxicity tests performed at 44.5 C revealed that no membranes were able to recover more than 40% of the test organisms. Since differences were found in the ability of the three brands of membrane filters to recover bacteria from natural and controlled sources, membrane filters from different manufacturers cannot be readily interchanged. There is a need for a standardized procedure for testing bacterial recovery by membrane filters.  相似文献   

4.
MacConkey agar, standard M-FC agar, M-FC agar without rosolic acid, M-FC agar with a resuscitation top layer, Teepol agar, and pads saturated with Teepol broth, were evaluated as growth media for membrane filtration counting of fecal coliform bacteria in water. In comparative tests on 312 samples of water from a wide variety of sources, including chlorinated effluents, M-FC agar without rosolic acid proved the medium of choice because it generally yielded the highest counts, was readily obtainable, easy to prepare and handle, and yielded clearly recognizable fecal coliform colonies. Identification of 1,139 fecal coliform isolates showed that fecal coliform tests cannot be used to enumerate Escherichia coli because the incidence of E. coli among fecal coliforms varied from an average of 51% for river water to 93% for an activated sludge effluent after chlorination. The incidence of Klebsiella pneumoniae among fecal coliforms varied from an average of 4% for the activated sludge effluent after chlorination to 32% for the river water. The advantages of a standard membrane filtration procedure for routine counting of fecal coliforms in water using M-FC agar without rosolic acid as growth medium, in the absence of preincubation or resuscitation steps, are outlined.  相似文献   

5.
A two-layer membrane filtration (MF) medium (injury-mitigating MF [IM-MF]) and a procedure for the enumeration of injured fecal coliforms are described. These procedures included the addition of glycerol and acetate plus reducing agents to both layers of a two-layer medium and rinsing of the filter with a rich resuscitation medium. Some changes in incubation time and temperatures were used. This method was compared with the multiple-tube fermentation most-probable-number procedure and the one-step M-FC agar-membrane filter method (direct M-FC) in terms of fecal coliform recovery from various aquatic environments that cause bacterial injury. With chlorinated sewage effluents, results of the IM-MF technique were equal to or greater than the most probable number in 9 of 18 trials and were 1.3 to 19 times greater than the M-FC method. When sewage samples were chlorinated in the laboratory, fecal coliform counts with IM-MF equaled or exceeded the most probable number in 7 of 15 trials and always exceeded the M-FC. M-FC was exceeded by IM-MF in 30 of 33 trials with clean mountain stream water. Fecal coliform bacteria that were exposed to low levels of an iodophore in the laboratory produced IM-MF counts 3 to 10 times greater than those with M-FC. A biochemical rationale for the formation of the IM-MF medium is discussed.  相似文献   

6.
A two-layer membrane filtration (MF) medium (injury-mitigating MF [IM-MF]) and a procedure for the enumeration of injured fecal coliforms are described. These procedures included the addition of glycerol and acetate plus reducing agents to both layers of a two-layer medium and rinsing of the filter with a rich resuscitation medium. Some changes in incubation time and temperatures were used. This method was compared with the multiple-tube fermentation most-probable-number procedure and the one-step M-FC agar-membrane filter method (direct M-FC) in terms of fecal coliform recovery from various aquatic environments that cause bacterial injury. With chlorinated sewage effluents, results of the IM-MF technique were equal to or greater than the most probable number in 9 of 18 trials and were 1.3 to 19 times greater than the M-FC method. When sewage samples were chlorinated in the laboratory, fecal coliform counts with IM-MF equaled or exceeded the most probable number in 7 of 15 trials and always exceeded the M-FC. M-FC was exceeded by IM-MF in 30 of 33 trials with clean mountain stream water. Fecal coliform bacteria that were exposed to low levels of an iodophore in the laboratory produced IM-MF counts 3 to 10 times greater than those with M-FC. A biochemical rationale for the formation of the IM-MF medium is discussed.  相似文献   

7.
Modification of M-FC medium by eliminating rosolic acid.   总被引:11,自引:10,他引:1       下载免费PDF全文
Eliminating rosolic acid from M-FC medium improves the MFC procedure by allowing higher fecal coliform colony recoveries with greater ease in counting. Samples of unchlorinated and chlorinated domestic sewage, creek, lake, and river water were analyzed for fecal coliforms by standard procedures. Results of 200 comparisons of fecal coliform counts on M-FC medium without and with rosolic acid showed that higher counts were obtained 71% of the time when rosolic acid was excluded without an overgrowth of background colonies. Results from analyzing chlorinated sewage showed that eliminating rosolic acid improved the recovery of fecal coliform bacteria by 49%. A total of 1,675 blue colonies and 766 nonblue colonies were verified. Of the 1,675 blue colonies, 1,566 were confirmed as fecal coliform bacteria, for a verification of 93.5%. The percent verification of nonblue colonies as noncoliform bacteria was 84.2% (644/766).  相似文献   

8.
Eliminating rosolic acid from M-FC medium improves the MFC procedure by allowing higher fecal coliform colony recoveries with greater ease in counting. Samples of unchlorinated and chlorinated domestic sewage, creek, lake, and river water were analyzed for fecal coliforms by standard procedures. Results of 200 comparisons of fecal coliform counts on M-FC medium without and with rosolic acid showed that higher counts were obtained 71% of the time when rosolic acid was excluded without an overgrowth of background colonies. Results from analyzing chlorinated sewage showed that eliminating rosolic acid improved the recovery of fecal coliform bacteria by 49%. A total of 1,675 blue colonies and 766 nonblue colonies were verified. Of the 1,675 blue colonies, 1,566 were confirmed as fecal coliform bacteria, for a verification of 93.5%. The percent verification of nonblue colonies as noncoliform bacteria was 84.2% (644/766).  相似文献   

9.
A Mates  M Schaffer 《Microbios》1986,46(186):45-49
Staphylococcus aureus counts from swimming pool water were determined by the membrane filtration technique. Water samples were passed through a membrane filter and then put on Baird-Parker media. After incubation, the filters were transferred to nutrient agar, and incubated at 37 degrees C, for 3 h. After removal of the filters, the plates were incubated at 60 degrees C for 2 h. An overlay of toluidine blue agar was added and the plates reincubated for 4 h at 37 degrees C. The formation of thermonuclease correlated with the formation of coagulase, and the results indicated that Staphylococcus aureus could be present in swimming pool water without the presence of either coliform or faecal coliform bacteria.  相似文献   

10.
Four membrane filter methods fecal coliform enumeration were evaluated and compared in six laboratories based on determination of accuracy, specificity, upper counting limit, and recovery comparability. Recovery accuracy with pure cultures ranged from 89 to 100% for m-FC, mTEC (a procedure developed for thermotolerant Escherichia coli), and m-FC2 methods (the latter incorporating a 2-h, 35 degrees C resuscitation period), but was less than 60% for the MacConkey membrane broth method. These figures dropped by approximately 40 to 55% when the cultures were subjected to temperature (10 degrees C) stress. Close to 800 colonies were verified to determine specificity. False-positive colonies occurred most frequently with the m-FC2 method (18%), whereas false-negative colonies were most common on MacConkey membrane broth (26%). In counting range experiments using a variety of samples, the highest upper counting limit was 130 colonies per filter with the mTEC procedure. Recovery comparisons were based on over 130 samples including raw surface waters, raw sewage, and chlorinated and unchlorinated sewage effluents. In general, recoveries were significantly higher with the m-FC2 and mTEC methods; however, on m-FC2, growth of nontarget background organisms was also higher in most cases. Highest recoveries from chlorinated sewage effluents were obtained by the mTEC method, and the addition of a similar resuscitation period to the m-FC procedure (m-FC2) improved fecal coliform recovery from such samples. The best overall performance for fecal coliform enumeration was obtained with the mTEC method with high recovery and low levels of background colonies, good specificity and accuracy, and a high upper counting limit. This procedure also offers the advantage of enumerating E. coli within 24 h.  相似文献   

11.
Pfizer selective enterococcus (PSE) and KF agars were compared for their recovery of fecal streptococci from sewage effluent on membrane filters. The results showed that PSE agar is highly selective for the enterococci. The tan color resulting from esculin hydrolysis, which was not always visible on the surfaces of the colonies, is not considered a necessary differential characteristic on PSE agar since more than 90% of all colonies recovered on membrane filters were confirmed as fecal streptococci and 86% were confirmed as enterococci. The detection of esculin hydrolysis on membrane filters was not improved by using the new Millipore type HC filter. KF agar recovered significantly greater numbers of organisms but was not as selective, with 83% of the typical colonies being confirmed as fecal streptococci and 54% as enterococci. An attempt to improve the selectivity of KF agar while retaining its inclusiveness by incubation at 45 C was not successful.  相似文献   

12.
A comparative study was made of nine commonly used membrane filters from five manufacturers, all recommended for enumeration of coliform bacteria. Bacterial recoveries and flow rates were examined from three types of water and were found to correlate with the surface pore structure determined by scanning electron microscopy. The sorption of metals was also determined. The results of these studies indicate that the five best membranes for fecal coliform recovery could be placed in two groups: Millipore HC and Gelman, followed by Johns-Manville SG and AG and Sartorius 13806.  相似文献   

13.
A comparative study was made of nine commonly used membrane filters from five manufacturers, all recommended for enumeration of coliform bacteria. Bacterial recoveries and flow rates were examined from three types of water and were found to correlate with the surface pore structure determined by scanning electron microscopy. The sorption of metals was also determined. The results of these studies indicate that the five best membranes for fecal coliform recovery could be placed in two groups: Millipore HC and Gelman, followed by Johns-Manville SG and AG and Sartorius 13806.  相似文献   

14.
Reports indicate that the standard membrane filter (MF) technique for recovery of fecal coliform bacteria from chlorinated sewage effluents is less effective than the multiple-tube (or most-probable-number [MPN]) procedure. A modified MF method was developed that requires a preincubation period of 5 h at 35 degrees C followed by 18+/-1 h at 44.5 degrees C. This procedure was evaluated by using both laboratory- and plant-chlorinated primary and secondary effluents. Results obtained by the modified MF method compared favorably with those of the MPN technique for the enumeration of fecal coliforms from chlorinated effluent. Agreement between these two methods was greatest with samples from secondary treatment plants. The average recovery of fecal coliforms by the standard MF procedure was only 14% that of the MPN method, whereas with the modified technique recovery was increased to 68% of the MPN counts. Enhanced recovery resulting from a simple modification in the incubation schedule makes the MF method a valuable adjunct for enumerating fecal coliforms from chlorinated effluents.  相似文献   

15.
Abstract Vibrio cholerae strain TSI-4 was incubated in an M9 salt solution at 15 °C for more than 100 days. The plate counts showed no viable cells on day 30, but a broth culture from that day showed the growth of bacteria. However, after 35 days the bacteria entered the nonculturable state, based on the assessment of both the plate counts and broth culture. A portion of the culture was heated at 45 °C for 1 min in a water bath and subsequently plated onto a nutrient agar plate. More than 1000 colonies were recovered after this heat-shock treatment. The recovered cells showed the same chromosomal DNA pattern in the restriction map and the same outer membrane protein pattern in SDS-PAGE. Recovery of viable cells by heat-shock was achieved in cultures grown on M9 salt but not from cultures grown in phosphate-buffered saline. This suggests that the presence of NH4Cl in the M9 salt solution may support the growth of the bacteria in a low nutrient medium, while also playing an important role in resuscitation.  相似文献   

16.
Reports indicate that the standard membrane filter (MF) technique for recovery of fecal coliform bacteria from chlorinated sewage effluents is less effective than the multiple-tube (or most-probable-number [MPN]) procedure. A modified MF method was developed that requires a preincubation period of 5 h at 35 degrees C followed by 18+/-1 h at 44.5 degrees C. This procedure was evaluated by using both laboratory- and plant-chlorinated primary and secondary effluents. Results obtained by the modified MF method compared favorably with those of the MPN technique for the enumeration of fecal coliforms from chlorinated effluent. Agreement between these two methods was greatest with samples from secondary treatment plants. The average recovery of fecal coliforms by the standard MF procedure was only 14% that of the MPN method, whereas with the modified technique recovery was increased to 68% of the MPN counts. Enhanced recovery resulting from a simple modification in the incubation schedule makes the MF method a valuable adjunct for enumerating fecal coliforms from chlorinated effluents.  相似文献   

17.
This study was undertaken to better characterize the groups of total coliforms (TC) and fecal coliforms (FC) and to evaluate both groups as indicators of fecal contamination of drinking well water in a tropical climate (The Ivory Coast, West Africa). Isolated colonies obtained as TC or FC on membrane filters were identified using the API-20E system. From the well water samples, 58 golden-green colonies with a metallic sheen isolated on Endo medium (TC) were identified as Escherichia coli (55%), Enterobacter (26%), Klebsiella (14%), Proteus (3%), and Citrobacter (2%). Among 132 colonies isolated on Endo medium as non-TC (not showing the characteristic golden metallic sheen), 10% were identified as E. coli. The 196 blue colonies isolated on M-FC medium at 44.5 degrees C (FC) were identified as E. coli (66%), Klebsiella (12%), Enterobacter (10%), Citrobacter (5%), Salmonella (3%), Serratia (3%), Proteus (2%), and Yersinia (0.5%). Among 24 nonblue colonies on M-FC medium, none were identified as E. coli. Of the colonies isolated from human feces, E. coli represents 92% of the TC and 89% of the FC. Although these results are limited, they tend to confirm the greater specificity of the fecal coliform technique over that of total coliform for the detection of fecal contamination of untreated well water. From the results presented here and the observations of other workers, it is suggested that the use of FC instead of TC should be considered as the method of choice for determining drinking water pollution of untreated groundwater supplies.  相似文献   

18.
A total of 529 well and distribution potable water samples were analyzed for total coliforms by the most-probable-number and membrane filter (MF) techniques. Standard plate count bacteria and MF noncoliform bacteria were also enumerated. Frequency of coliform detection, turbidity in most-probable-number tubes, and extensive overgrowth by noncoliforms on MF filters were directly proportional to standard plate counts. Recovery of coliforms was greatest by the MF method at low (less than 100 CFU/ml) standard plate count densities and better by the most-probable-number method (confirming gas and turbid tube) at high (greater than 500 CFU/ml) standard plate count densities. In the latter case, overgrowth by noncoliforms on MF filters suppressed sheen development and, in turn, masked coliform detection. Of 341 atypical (no sheen) MF colonies verified by parallel inoculation of lauryl sulfate broth and billiant green-bile broth, 156 were aerogenic in the latter medium. Of atypical isolates, 84% were identified as either Citrobacter or Enterobacter species. A 4.3-fold reduction in numbers of overgrown MF filters and an 2.2-fold increase in numbers of coliforms recovered from 127 water samples was accomplished by anaerobic incubation of MF cultures. This anaerobic modification of the standard MF technique significantly reduced overgrowth and enhanced recovery of coliforms from potable groundwater. This technique is simple, cost effective, and suitable for monitoring of untreated ground water common to some small water systems and private water supplies.  相似文献   

19.
A total of 529 well and distribution potable water samples were analyzed for total coliforms by the most-probable-number and membrane filter (MF) techniques. Standard plate count bacteria and MF noncoliform bacteria were also enumerated. Frequency of coliform detection, turbidity in most-probable-number tubes, and extensive overgrowth by noncoliforms on MF filters were directly proportional to standard plate counts. Recovery of coliforms was greatest by the MF method at low (less than 100 CFU/ml) standard plate count densities and better by the most-probable-number method (confirming gas and turbid tube) at high (greater than 500 CFU/ml) standard plate count densities. In the latter case, overgrowth by noncoliforms on MF filters suppressed sheen development and, in turn, masked coliform detection. Of 341 atypical (no sheen) MF colonies verified by parallel inoculation of lauryl sulfate broth and billiant green-bile broth, 156 were aerogenic in the latter medium. Of atypical isolates, 84% were identified as either Citrobacter or Enterobacter species. A 4.3-fold reduction in numbers of overgrown MF filters and an 2.2-fold increase in numbers of coliforms recovered from 127 water samples was accomplished by anaerobic incubation of MF cultures. This anaerobic modification of the standard MF technique significantly reduced overgrowth and enhanced recovery of coliforms from potable groundwater. This technique is simple, cost effective, and suitable for monitoring of untreated ground water common to some small water systems and private water supplies.  相似文献   

20.
Millipore Coli-Count Samplers were used to enumerate colonies of laboratory cultures of coliform bacteria. The samplers gave significantly lower counts than standard membrane-filter procedures for both total and fecal coliforms. Although the samplers are useful for semiquantitative analysis as indicated by the manufacturer, they are not suitable for standard examinations of recreational waters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号