首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
临床颅底外科手术中充满各种风险,特别是有对神经系统结构造成损伤的潜在风险。有些损伤无法通过直接观察来判断,因此术中电生理监测(intraoperative neuroelectrophysiological monitoring,IONM)是神经外科手术医生术中实时监测和评估神经功能的重要手段。国外上世纪80年代就将其应用于颅底肿瘤手术中,但直至目前我国相关应用仍未普及。术中神经电生理监测是运用各种电生理技术,实时监测术中处于有损伤风险的神经系统功能的完整性,并提示手术医生及时终止风险性操作,有针对性的采取有效干预措施消除或减小神经损伤、改善患者预后的一门技术。近年来,颅底外科进展迅速,并向多学科协作和减少创伤的方向发展,术中神经电生理监测已经迅速发展为降低颅底手术中神经损伤发生率的重要辅助手段。  相似文献   

2.
OBJECTIVE: To investigate the diagnostic accuracy and current role of intraoperative cytologic smears of central nervous system tumors. STUDY DESIGN: Retrospective analysis of 4,172 patients operated on during 1985-1999, with 3,541 intraoperative smears performed during open procedures and 631 during stereotactic biopsies. RESULTS: Complete correlation with the final diagnosis was achieved in a mean of 89.8% (range, 83-93.7% per year). Diagnostic accuracy increased to 95% on average (range, 91.5-96.7% per year) when cases of partial correlation, mainly due to grading deviations, were included. The most accurate intraoperative diagnoses were obtained in cases of meningioma (97.9%), metastasis (96.3%) and glioblastoma (95.7%). A significant reduction in diagnostic accuracy was observed in cases of oligodendroglioma (80.9%) and ependymoma (77.7%). Besides diagnosis and grading, smear cytology provided resection guidance in cases of well-delineated tumors. CONCLUSION: Intraoperative smears in neurosurgery are easy to obtain and inexpensive and have high diagnostic accuracy. In addition to stereotactic biopsy procedures, intraoperative smears permit reliable intraoperative guidance during lesion targeting and resection.  相似文献   

3.
A new apparatus for CT-guided stereotactic surgery   总被引:1,自引:0,他引:1  
Combining whole-body CT scan with a stereotactic system, the authors have developed and applied clinically an apparatus which readily provides intraoperative CT images, making it possible to confirm the location of the target point and ascertain the intraoperative environment. It takes about 9 s to obtain a CT image. Our purpose is to make stereotactic surgery, a kind of blind surgery, as safe and reliable as a visualized procedure by intraoperative CT scanning. By the method, in which there is very little invasion under local anesthesia, evacuation of deep-seated intracerebral hematomas as well as brain abscesses and also biopsy or brachytherapy of brain tumors in the brain can be done with safety and reliability.  相似文献   

4.
OBJECTIVE: To evaluate the utility of rapid intraoperative crush smear cytologic diagnosis of central and peripheral nervous system lesions and to determine the accuracy and relevance of the accuracy of the intraoperative cytologic diagnosis when compared to the final paraffin section diagnosis. STUDY DESIGN: The crush (squash) smear technique was introduced at Sher-i-Kashmir Institute of Medical Sciences in May 2003. The 8 months of 2003 were used for standardization of the procedure. In 2004, 151 patients with open neurosurgical specimens or stereotactic biopsies were diagnosed intraoperatively by crush smears, and the diagnosis was compared with final diagnosis on paraffin sections of the same tissue samples. No supplementation of frozen sections was used. RESULTS: Of 151 cases, 144 were diagnosed accurately intraoperatively by crush smear cytology when compared with the respective paraffin section diagnoses. The diagnostic accuracy attained was 95.36%. Each case was diagnosed within 10 minutes after receipt of sample. Neurosurgical procedure (open or stereotaxy) did not affect diagnostic accuracy. CONCLUSION: In the expert hands of a pathologist with good exposure neurosurgical specimens, crush smear cytology is an accura and reliable procedure for the intraoperative diagnosis central nervous system tumors.  相似文献   

5.

Introduction

Ultrasound can visualize and update the vessel status in real time during cerebral vascular surgery. We studied the depiction of parent vessels and aneurysms with a high-resolution 3D intraoperative ultrasound imaging system during aneurysm clipping using rotational digital subtraction angiography as a reference.

Methods

We analyzed 3D intraoperative ultrasound in 39 patients with cerebral aneurysms to visualize the aneurysm intraoperatively and the nearby vascular tree before and after clipping. Simultaneous coregistration of preoperative subtraction angiography data with 3D intraoperative ultrasound was performed to verify the anatomical assignment.

Results

Intraoperative ultrasound detected 35 of 43 aneurysms (81%) in 39 patients. Thirty-nine intraoperative ultrasound measurements were matched with rotational digital subtraction angiography and were successfully reconstructed during the procedure. In 7 patients, the aneurysm was partially visualized by 3D-ioUS or was not in field of view. Post-clipping intraoperative ultrasound was obtained in 26 and successfully reconstructed in 18 patients (69%) despite clip related artefacts. The overlap between 3D-ioUS aneurysm volume and preoperative rDSA aneurysm volume resulted in a mean accuracy of 0.71 (Dice coefficient).

Conclusions

Intraoperative coregistration of 3D intraoperative ultrasound data with preoperative rotational digital subtraction angiography is possible with high accuracy. It allows the immediate visualization of vessels beyond the microscopic field, as well as parallel assessment of blood velocity, aneurysm and vascular tree configuration. Although spatial resolution is lower than for standard angiography, the method provides an excellent vascular overview, advantageous interpretation of 3D-ioUS and immediate intraoperative feedback of the vascular status. A prerequisite for understanding vascular intraoperative ultrasound is image quality and a successful match with preoperative rotational digital subtraction angiography.  相似文献   

6.
A pictorial system is introduced for documenting intraoperative maneuvers in rhinoplasty that can be used to advantage for relating the effect that different surgical techniques have on postoperative results and for describing to other surgeons the technical steps performed in the operation.  相似文献   

7.
Current intraoperative imaging systems are typically not able to provide ‘sharp’ images over entire large areas or entire organs. Distinct structures such as tissue margins or groups of malignant cells are therefore often difficult to detect, especially under low signal‐to‐noise‐ratio conditions. In this report, we introduce a noise suppressed multifocus image fusion algorithm, that provides detailed reconstructions even when images are acquired under sub‐optimal conditions, such is the case for real time fluorescence intraoperative surgery. The algorithm makes use of the Anscombe transform combined with a multi‐level stationary wavelet transform with individual threshold‐based shrinkage. While the imaging system is integrated with a respiratory monitor triggering system, it can be easily adapted to any commercial imaging system. The developed algorithm is made available as a plugin for Osirix. (© 2013 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

8.
The real-time requirement means that the simulation should be able to follow the actions of the user that may be moving in the virtual environment. The computer system should also store in its memory a three-dimensional (3D) model of the virtual environment. In that case a real-time virtual reality system will update the 3D graphic visualization as the user moves, so that up-to-date visualization is always shown on the computer screen. Upon completion of the tele-operation, the surgeon compares the preoperative and postoperative images and models of the operative field, and studies video records of the procedure itself Using intraoperative records, animated images of the real tele-procedure performed can be designed. Virtual surgery offers the possibility of preoperative planning in rhinology. The intraoperative use of computer in real time requires development of appropriate hardware and software to connect medical instrumentarium with the computer and to operate the computer by thus connected instrumentarium and sophisticated multimedia interfaces.  相似文献   

9.
We have developed novel stereoscopic wearable multimodal intraoperative imaging and display systems entitled Integrated Imaging Goggles for guiding surgeries. The prototype systems offer real time stereoscopic fluorescence imaging and color reflectance imaging capacity, along with in vivo handheld microscopy and ultrasound imaging. With the Integrated Imaging Goggle, both wide-field fluorescence imaging and in vivo microscopy are provided. The real time ultrasound images can also be presented in the goggle display. Furthermore, real time goggle-to-goggle stereoscopic video sharing is demonstrated, which can greatly facilitate telemedicine. In this paper, the prototype systems are described, characterized and tested in surgeries in biological tissues ex vivo. We have found that the system can detect fluorescent targets with as low as 60 nM indocyanine green and can resolve structures down to 0.25 mm with large FOV stereoscopic imaging. The system has successfully guided simulated cancer surgeries in chicken. The Integrated Imaging Goggle is novel in 4 aspects: it is (a) the first wearable stereoscopic wide-field intraoperative fluorescence imaging and display system, (b) the first wearable system offering both large FOV and microscopic imaging simultaneously, (c) the first wearable system that offers both ultrasound imaging and fluorescence imaging capacities, and (d) the first demonstration of goggle-to-goggle communication to share stereoscopic views for medical guidance.  相似文献   

10.
Intraoperative measurement of hip posture is the basis for assessing hip range of motion (ROM) and predicting postoperative functional limits allowable for activities of daily living. Although computer navigation for total hip arthroplasty (THA) has improved the accuracy of intraoperative ROM evaluation, it has not gained widespread popularity due to its complex and time-consuming protocol. We therefore developed an inertial measurement unit-based hip smart trial system (IMUHST) for intraoperative monitoring of hip posture. An in vitro validation experiment was conducted using bone models with a three-dimensional measurement model as the reference standard. The absolute mean error, Bland – Altman analysis and intra-class correlation coefficient demonstrated that the validity and reliability of this system meets the requirement for clinical application. Given that monitoring posture is the basis for evaluating the direction(s) of potential impingement, subluxation and dislocation, the IMUHST is a promising development direction of computer assisted surgery in THA.  相似文献   

11.
Sentinel lymph node (SLN) biopsy is now standard practice in the management of many breast cancer patients. Localization protocols vary in complexity and rates of success. The least complex involve only intraoperative gamma counting of radiotracer uptake or intraoperative visualization of blue-dye uptake; the most complex involve preoperative gamma imaging, intraoperative counting and intraoperative dye visualization. Intraoperative gamma imaging may improve some protocols. This study was conducted to obtain preliminary experience and information regarding intraoperative imaging. Sixteen patients were enrolled: 8 in a protocol that included intraoperative counting and dye visualization (probe/dye), 8 in a protocol that involved intraoperative imaging, counting and dye visualization (camera/probe/dye). Preoperative imaging of all 16 patients was performed using a GE 500 gamma camera with a LEAP collimator (300 cpm/μCi). The results of this imaging were not, however, given to the surgeon until the surgeon had completed the procedures required for the study. A Care Wise C-Trak probe was used for intraoperative counting. A Gamma Medica Inc. GammaCAM/OR (12.5 × 12.5 cm FOV) with a LEHR collimator (135 cpm/μCi) was used for intraoperative imaging. Times from start of surgery to external detection of a radioactive focus and to completion of excision of SLNs were recorded. Foci were detected preoperatively via imaging in 16/16 patients. Intraoperative external detection using the probe was accomplished in less than 4 min (mean = 1.5 min) in 15/16 patients, and via intraoperative imaging in 6/8 patients. The average time for completion of excision of nodes was 19 min for probe/dye and 28 min for camera/probe/dye. In one probe/dye case, review of the preoperative images prompted the surgeon to resume axillary dissection and remove one additional SLN.  相似文献   

12.
Chen KT 《Acta cytologica》2003,47(6):1091-1094
BACKGROUND: Primary melanocytic neoplasms of the central nervous system are rare. There is no previous report on the intraoperative crush cytology of these neoplasms. CASE: A melanocytoma occurred in a 65-year-old woman who presented with back pain, and weakness and numbness of the right lower extremity. Magnetic resonance imaging revealed an enhancing mass in the conus medullaris. The tumor was subtotally removed. Crush smears revealed dispersed and perivascular aggregates of monotonous oval or spindle tumor cells with round or oval, uniform nuclei; small nucleoli; and long cytoplasmic processes. Some tumor cells contained fine or coarse cytoplasmic brown pigments. The pigments were easier to discern in the crush smears than in the frozen sections. CONCLUSION: Crush cytology appears to be helpful, alone or in conjunction with frozen sections, in the intraoperative diagnosis of meningeal melanocytoma.  相似文献   

13.
In vivo models of hepatic ischaemia/reperfusion injury (IRI) are widely used to study both the mechanisms of hepatic ischaemic injury and to seek means of hepatic protection. Achieving high-quality reproducible data are essential if the results of multiple studies are to be compared and reconciled. This paper presents our findings concerning the effect of intraoperative thermoregulation upon signal to noise ratios of hepatic IRI experiments in mice. Four experiments were conducted, using three different strategies for core temperature maintenance. Animals underwent hepatic IRI and euthanized 24 h postoperatively for measurement of plasma alanine aminotransferase (ALT). Duration of ischaemia was used to adjust the severity of injury. Experiment 1 utilized a constant output heating system and resulted in rising postoperative ALTs following increasing durations of hepatic ischaemia. Experiment 2, using the same constant output heating system confirmed a difference between ischaemic and sham-operated animals. Experiment 3 used a thermostatically controlled heating system and resulted in highly variable results with a small, but statistically significant correlation between ALT levels and rectal temperature readings. Experiment 4 used a homeothermic warming system and demonstrated highly reproducible data from increasing durations of ischaemia. High-quality data from hepatic ischaemia/reperfusion models are dependent upon careful control of intraoperative temperature. The use of homeothermic warming systems is recommended and conversely, the use of thermostatically controlled warming mats is to be avoided in these models.  相似文献   

14.

Objective

Intraoperative histopatological examination of the sentinel nodes enables selection of patients who need dissection of the regional lymphatic system during the same operation. The aim of this study is to evaluate the diagnostic value of intraoperative histopathological examination of the sentinel nodes in breast cancer and skin melanoma. Intraoperative histopathology of the sentinel nodes as a diagnostic method is used in patients with melanoma and breast cancer. Recent studies have proved it to be an effective method for evaluating the nodes in the final histopathology. Intraoperative histopathological examination of the sentinel nodes is not performed routinely and there is no clear position on this issue. In this paper we try to prove that intraoperative test gives patients the simultaneous benefits of removal of regional lymph nodes metastases and earlier initiation of adjuvant therapy.

Methods

The study comprises 137 patients with breast cancer and 35 patients with malignant skin melanoma. Sentinel nodes were intraoperatively sectioned and examined by means of the imprint method and frozen section evaluation. The patients with positive sentinel nodes underwent immediate dissection of regional lymph nodes. Those with negative sentinel nodes diagnosed in the intraoperative examination, but positive in final pathologic results, underwent subsequent dissection of regional lymph nodes.

Results

60 sentinel lymph nodes were found in 35 patients with skin melanoma. In 3 patients, 3 sentinel lymph nodes were false negative in the intraoperative histopathological examination. No false positive sentinel lymph nodes were found. 249 sentinel lymph nodes were found in the intraoperative histopathological examination in 137 patients with breast cancer. There were no false positive sentinel nodes, but there were 7 false negative sentinel nodes. In this study, only 5 (3.6%) patients with breast cancer and 3 (8.5%) patients with skin melanoma required another regional operation.

Conclusion

The method of intraoperative histopathological evaluation of the sentinel nodes enables identification of metastases in these lymph nodes and gives a possibility to carry out a one-step regional lymphadenectomy and start the adjuvant therapy earlier.  相似文献   

15.
Intraoperative assessment of graft anastomoses is commonly performed after off-pump coronary artery bypass grafting (OPCAB). The SPY imaging system allows intraoperative graft assessment. We document correlation between intraoperative SPY images and wall motion abnormality by transesophageal echocardiogram (TEE) during OPCAB. A 79-year-old female underwent OPCAB. Intraoperative graft patency assessment was performed with the SPY and left ventricular wall motion was assessed by TEE. SPY imaging demonstrated poor flow trough the distal vein graft anastomosis to the posterior descending artery, which correlated with a new posterior wall motion hypokinesis. After graft revision, SPY imaging demonstrated good distal flow and the TEE demonstrated normalization of the left ventricular posterior wall motion. SPY technology allows the surgeon to accurately assess graft patency intraoperatively and allows immediate correction of a technical problem.  相似文献   

16.
IntroductionPedicle screws are commonly employed to restore spinal stability and correct deformities. The Renaissance robotic system was developed to improve the accuracy of pedicle screw placement.PurposeIn this study, we developed an intraoperative classification system for evaluating the accuracy of pedicle screw placements through secondary registration. Furthermore, we evaluated the benefits of using the Renaissance robotic system in pedicle screw placement and postoperative evaluations. Finally, we examined the factors affecting the accuracy of pedicle screw implantation.ResultsThrough use of the Renaissance robotic system, the accuracy of Kirschner-wire (K-wire) placements deviating <3 mm from the planned trajectory was determined to be 98.74%. According to our classification system, the robot-guided pedicle screw implantation attained an accuracy of 94.00% before repositioning and 98.74% after repositioning. However, the malposition rate before repositioning was 5.99%; among these placements, 4.73% were immediately repositioned using the robot system and 1.26% were manually repositioned after a failed robot repositioning attempt. Most K-wire entry points deviated caudally and laterally.ConclusionThe Renaissance robotic system offers high accuracy in pedicle screw placement. Secondary registration improves the accuracy through increasing the precision of the positioning; moreover, intraoperative evaluation enables immediate repositioning. Furthermore, the K-wire tends to deviate caudally and laterally from the entry point because of skiving, which is characteristic of robot-assisted pedicle screw placement.  相似文献   

17.
Intraoperative autotransfusion salvages blood shed during surgery for use in immediate resuscitation of the patient. The purpose of this study was to determine whether such autotransfusion decreases the volume of homologous blood transfused in patients undergoing primary cranial vault remodeling for craniosynostosis. The Cobe-Bret 2 autologous blood recovery system (Hemo Concepts, Union, N.J.) was used in 11 cases, and an equal number of consecutive cases did not receive intraoperative autotransfusion. There were no significant differences between the groups with respect to age, sex, and weight. Mean estimated blood loss was 43.2 ml/kg (range, 20.3 to 65.0 ml/kg) in the intraoperative autotransfusion group and 40.2 ml/kg (range, 6.8 to 72.3 ml/kg) in the control group (not statistically significant; p < 0.05). There was no significant difference in volume of homologous blood transfusion between the two groups. The autotransfusion group received 34.1 ml/kg of homologous blood (range, 0 to 60.7 ml/kg), and the control group received a mean of 32.7 ml/kg (range, 14.5 to 60.2 ml/kg). The autotransfusion group received a mean of 10.4 ml/kg of recovered autologous blood (range, 0 to 21.4 ml/kg). In four of the 11 autotransfusion patients, insufficient autologous blood was recovered intraoperatively to warrant transfusion. Results of this study suggest little benefit for the use of intraoperative autotransfusion in primary cranial vault remodeling for craniosynostosis in the young patient. It was hypothesized that this finding was a result of the following: (1) intraoperative autotransfusion blood was usually available only toward the end of the procedure, after homologous blood had already been administered, and (2) the volume of recovered intraoperative autotransfusion blood is minimal, compared with the homologous transfusion volume requirements during an extensive cranial vault remodeling and fronto-orbital advancement procedure. In the context of unproven cost benefit and increasing similar evidence from other comparative studies, emphasis should be directed to other medical and surgical strategies to minimize the need for perioperative blood transfusion.  相似文献   

18.
The prognosis in advanced-stage ovarian cancer remains poor. Tumor-specific intraoperative fluorescence imaging may improve staging and debulking efforts in cytoreductive surgery and thereby improve prognosis. The overexpression of folate receptor-α (FR-α) in 90-95% of epithelial ovarian cancers prompted the investigation of intraoperative tumor-specific fluorescence imaging in ovarian cancer surgery using an FR-α-targeted fluorescent agent. In patients with ovarian cancer, intraoperative tumor-specific fluorescence imaging with an FR-α-targeted fluorescent agent showcased the potential applications in patients with ovarian cancer for improved intraoperative staging and more radical cytoreductive surgery.  相似文献   

19.
Intraoperative Cerenkov luminescence imaging (CLI) can effectively improve the performance of tumor surgery. Nevertheless, the existing approaches are still unsatisfying to the clinical demands of open surgery. This study develops a novel intraoperative in vivo CLI approach to investigate the potential and value of Cerenkov luminescence (CL) image‐guided surgery. A system characterized with high sensitivity (19.61 kBq mL?1 18F‐FDG) and desirable spatial resolution (88.34 μm) is developed. CL image‐guided surgery is performed on colorectal cancer (CRC) models of mice and swine. Tumor surgery is guided by the static CL images, and the resection quality is evaluated quantitatively and contrasted with other imaging modalities exemplified by bioluminescence imaging (BLI). The in vivo results demonstrated the effectiveness of the proposed intraoperative CLI approach for removing primary and metastatic CRC. Safety of performing in vivo CL image‐guided surgery is verified as well through radiation measurements of related staffs. Overall, the developed intraoperative in vivo CLI approach can efficiently improve the cancer treatment.  相似文献   

20.
The authors present their initial experience in physical aspects of treatment planning in HDR intraoperative brachytherapy. The examples are given of implantations in various tumour localizations: head and neck, pancreas, soft tissue sarcomas in the abdomen. The technical and dosimetric problems which may occur in such situations are discussed. The capabilities of dose distribution optimization by the Abacus HDR treatment planning system are presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号