首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We have developed a simple and renewable electrochemical biosensor based on carbon paste electrode (CPE) for the detection of DNA synthesis and hybridization. CPE was modified with gold nanoparticles (AuNPs), which are helpful for immobilization of thiolated bioreceptors. AuNPs were characterized by scanning electron microscopy (SEM). Self-assembled monolayers (SAMs) of thiolated single-stranded DNA (SH–ssDNA) of the amelogenin gene was formed on CPE. The immobilization of the probe and its hybridization with the target DNA was optimized using different experimental conditions. The modified electrode was characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The electrochemical response of ssDNA hybridization and DNA synthesis was measured using differential pulse voltammetry (DPV) with methylene blue (MB) as an electroactive indicator. The new biosensor can distinguish between complementary and non-complementary strands of amelogenin ssDNA. Genomic DNA was extracted from blood and was detected based on changes in the MB reduction signal. These results demonstrated that the new biosensor could be used for sex determination. The proposed biosensor in this study could be used for detection and discrimination of polymerase chain reaction (PCR) products of amelogenin DNA.  相似文献   

2.
A simple and sensitive electrochemical DNA biosensor based on in situ DNA amplification with nanosilver as label and horseradish peroxide (HRP) as enhancer has been designed. The thiolated oligomer single-stranded DNA (ssDNA) was initially directly immobilized on a gold electrode, and quartz crystal microbalance (QCM) gave the specific amount of ssDNA adsorption of 6.3 ± 0.1 ng/cm2. With a competitive format, hybridization reaction was carried out via immersing the DNA biosensor into a stirred hybridization solution containing different concentrations of the complementary ssDNA and constant concentration of nanosilver-labeled ssDNA, and then further binding with HRP. The adsorbed HRP amount on the probe surface decreased with the increment of the target ssDNA in the sample. The hybridization events were monitored by using differential pulse voltammetry (DPV) with the adsorbed HRP toward the reduction of H2O2. The reduction current from the enzyme-generated product was related to the number of target ssDNA molecules in the sample. A detection of 15 pmol/L for target ssDNA was obtained with the electrochemical DNA biosensor. Additionally, the developed approach can effectively discriminate complementary from non-complementary DNA sequence, suggesting that the similar enzyme-labeled DNA assay method hold great promises for sensitive electrochemical biosensor applications.  相似文献   

3.
A direct electrochemical DNA biosensor based on zero current potentiometry was fabricated by immobilization of ssDNA onto gold nanoparticles (AuNPs) coated pencil graphite electrode (PGE). One ssDNA/AuNPs/PGE was connected in series between clips of working and counter electrodes of a potentiostat, and then immersed into the solution together with a reference electrode, establishing a novel DNA biosensor for specific DNA detection. The variation of zero current potential difference (ΔE(zcp)) before and after hybridization of the self-assembled probe DNA with the target DNA was used as a signal to characterize and quantify the target DNA sequence. The whole DNA biosensor fabrication process was characterized by cyclic voltammetry and electrochemical impedance spectroscopy with the use of ferricyanide as an electrochemical redox indicator. Under the optimized conditions, ΔE(zcp) was linear with the concentrations of the complementary target DNA in the range from 10nM to 1μM, with a detection limit of 6.9nM. The DNA biosensor showed a good reproducibility and selectivity. Prepared DNA biosensor is facile and sensitive, and it eliminates the need of using exogenous reagents to monitor the oligonucleotides hybridization.  相似文献   

4.
The present work demonstrates a rapid, single-step and ultrasensitive label-free and signal-off electrochemical sensor for specific DNA detection with excellent discrimination ability for single-nucleotide polymorphisms, taking advantage of Exonuclease III (Exo III)-aided target recycling strategy to achieve signal amplification. Exo III has a specifical exo-deoxyribonuclease activity for duplex DNAs in the direction from 3' to 5' terminus, however its activity on the duplex DNAs with 3'-overhang and single-strand DNA is limited. In response to the specific features of Exo III, the proposed E-DNA sensor is designed such that, in the presence of target DNA, the electrode self-assembled signaling probe hybridizes with the target DNA to form a duplex in the form of a 3'-blunt end at signaling probe and a 3'-overhang end at target DNA. In this way, Exo III specifically recognizes this structure and selectively digests the signaling probe. As a result, the target DNA dissociates from the duplex and recycles to hybridize with a new signaling probe, leading to the digestion of a large amount of signaling probes gradually. A redox mediator, Ru(NH(3))(6)(3+) (RuHex) is employed to electrostatically adsorbed onto signaling probes, which is directly related to the amount and the length of the signaling probes remaining in the electrode, and provides a quantitative measure of sequence-specific DNA with the experimentally measured (not extrapolated) detection limit as low as 20 fM. Moreover, this E-DNA sensor has an excellent differentiation ability for single mismatches with fairly good stability.  相似文献   

5.
We report a strategy for the transduction of DNA hybridization into a readily detectable photoelectrochemical signal by means of a conformational change analogous to electrochemical DNA (E-DNA) approach. To demonstrate the effect of distance change for photosensitizer to the surface of electrode on the change of photocurrent, photosensitizer Ru(bpy)(2)(dcbpy)(2+) tagged DNA stem-loop structures were self-assembled onto a nanogold modified ITO electrode. Hybridization induced a large conformational change in DNA structure, which in turn significantly altered the electron-transfer tunneling distance between the electrode and photosensitizer. The resulting change in photocurrent was proportional to the concentration of DNA in the range of 1.0×10(-10)-8.0×10(-9)M. In order to improve the sensitivity of the photoelectrochemical biosensor, an amplified detection method based on isothermal strand displacement polymerization reaction was employed. With multiple rounds of isothermal strand replication, which led to strand displacement and constituted consecutive signal amplification, a detection limit of 9.4×10(-14)M target DNA was achieved.  相似文献   

6.
A new procedure for fabricating deoxyribonucleic acid (DNA) electrochemical biosensor was developed based on covalent immobilization of target single-stranded DNA (ssDNA) on Au electrode that had been functionalized by direct coupling of sol-gel and self-assembled technologies. Two siloxanes, 3-mercaptopropyltrimethoxysiloxane (MPTMS) and 3-glycidoxypropyltrimethoxysiloxane (GPTMS) were used as precursors to prepare functionally self-assembly sol-gel film on Au electrode. The thiol group of MPTMS allowed assembly of MPTMS sol-gel on gold electrode surface. Through co-condensation between silanols, GPTMS sol-gel with epoxide groups interconnected into MPTMS sol-gel and enabled covalent immobilization of target NH(2)-ssDNA through epoxide/amine coupling reaction. The concentration of MPTMS and GPTMS influenced the performance of the resulting biosensor due to competitive sol-gel process. The linear range of the developed biosensor for determination of complementary ssDNA was from 2.51 x 10(-9) to 5.02 x 10(-7)M with a detection limit of 8.57 x 10(-10)M. The fabricated biosensor possessed good selectivity and could be regenerated. The covalent immobilization of target ssDNA on self-assembled sol-gel matrix could serve as a versatile platform for DNA immobilization and fabrication of biosensors.  相似文献   

7.
An electrochemical DNA sensor based on the hybridization recognition of a single-stranded DNA (ssDNA) probe immobilized onto a gold electrode to its complementary ssDNA is presented. The DNA probe is bound on gold surface electrode by using self-assembled monolayer (SAM) technology. An optimized mixed SAM with a blocking molecule preventing the nonspecific adsorption on the electrode surface has been prepared. In this paper, a DNA biosensor is designed by means of the immobilization of a single stranded DNA probe on an electrochemical transducer surface to recognize specifically Escherichia coli (E. coli) 0157:H7 complementary target DNA sequence via cyclic voltammetry experiments. The 21 mer DNA probe including a C6 alkanethiol group at the 5' phosphate end has been synthesized to form the SAM onto the gold surface through the gold sulfur bond. The goal of this paper has been to design, characterise and optimise an electrochemical DNA sensor. In order to investigate the oligonucleotide probe immobilization and the hybridization detection, experiments with different concentration of DNA and mismatch sequences have been performed. This microdevice has demonstrated the suitability of oligonucleotide Self-assembled monolayers (SAMs) on gold as immobilization method. The DNA probes deposited on gold surface have been functional and able to detect changes in bases sequence in a 21-mer oligonucleotide.  相似文献   

8.
Liu N  Gao Z  Zhou H  Yue M 《Biosensors & bioelectronics》2007,22(9-10):2371-2376
This work reports a kind of novel bilayer lipid membranes (BLMs) nucleic acid biosensor supported by modified patch-clamp pipette electrode was developed to detect staphylococcus enterotoxins B (SEB) gene. BLMs were formed within 15 min and able to be operated at least 24 h. Hydrophobic dodecane tail (C12) modified 18 bp single-stranded DNA (ssDNA) probe was immobilized on BLMs. The electrochemical currents versus the different concentration of ssDNA probe immobilized on BLMs indicated linearly correlation. The BLMs nucleic acid biosensor was fabricated by selecting the ssDNA probe as the signal sensing element with the concentration of 273.65 ng/mL. The electrochemical performance of the biosensor for the detection of SEB was investigated. The result showed that linear relationship was found between the current and ln(concentration) from 20 to 5000 ng/mL and the detection limit was 20 ng/mL. In addition, the biosensor was specific response to SEB gene and showed no significant current alteration in electrolyte which containing no SEB gene. Finally, Atom Force Microscope (AFM) images could be observed and used to evaluate the superficial microstructure of BLMs, ssDNA immobilized on BLMs and BLMs after hybridization. The BLMs nucleic acid biosensor supported by modified patch-clamp pipette electrode will become a highly sensitive, rapid, selective analytical tool for detection of Staphylococcus aureus, which produce SEB.  相似文献   

9.
In this study, a novel DNA electrochemical probe (locked nucleic acid, LNA) was designed and involved in constructing an electrochemical DNA biosensor for detection of promyelocytic leukemia/retinoic acid receptor alpha (PML/RARα) fusion gene in acute promyelocytic leukemia for the first time. This biosensor was based on a 'sandwich' sensing mode, which involved a pair of LNA probes (capture probe immobilized at electrode surface and biotinyl reporter probe as an affinity tag for streptavidin-horseradish peroxidase (streptavidin-HRP). Since biotin can be connected with streptavidin-HRP, this biosensor offered an enzymatically amplified electrochemical current signal for the detection of target DNA. In the simple hybridization system, DNA fragment with its complementary DNA fragment was evidenced by amperometric detection, with a detection limit of 74 fM and a linear response range of 0.1-10 pM for synthetic PML/RARα fusion gene in acute promyelocytic leukemia (APL). Otherwise, the biosensor showed an excellent specificity to distinguish the complementary sequence and different mismatch sequences. The new pattern also exhibited high sensitivity and selectivity in mixed hybridization system.  相似文献   

10.
An electrically neutral cobalt complex, Co(Eim)(4)(NCS)(2) (Eim=1-ethylimidazole, NCS=isothiocyanate) was synthesized and its interaction with double-stranded DNA (dsDNA) was comprehensively studied by electrochemical methods on a glassy carbon electrode (GCE). The experimental results revealed that the cobalt complex could interact with dsDNA via a specific groove-binding mode with an affinity constant of 3.6×10(5)M(-1). The surface-based studies showed that Co(Eim)(4)(NCS)(2) could electrochemically accumulate within the immobilized dsDNA layer rather than single-stranded DNA (ssDNA) layer. Based on this fact, the cobalt complex was utilized as an electrochemical hybridization indicator for the detection of oligonucleotides related to CaMV35S promoter gene. The results showed that the developed biosensor presented very low background interference due to the negligible affinity of the Co(Eim)(4)(NCS)(2) complex with ssDNA. The hybridization specificity experiments further indicated that the biosensor could well discriminate the complementary sequence from the base-mismatched and the non-complementary sequences. The complementary target sequence could be quantified over the range from 5.0×10(-9)M to 2.0×10(-6)M with a detection limit of 2.0×10(-10)M.  相似文献   

11.
In this work we have developed a novel electrochemical biosensor for the detection of alkaline phosphatase (AP) by the use of two complementary DNA probes (DNA 1 and DNA 2) coupled with λ exonuclease (λ exo). Firstly, the 5'-phosphoryl end of DNA 1 is dephosphorylated by AP. Then DNA 1 hybridizes with DNA 2, previously modified on a gold electrode surface. In this double-strand DNA, DNA 2 strand will be promptly cleaved by λ exo with its phosphoryl at the 5' end. After the DNA 2 strand is completely digested, DNA 1 will be released from the double strands and then hybridizes with another DNA 2 strand on the electrode surface, thus the cycle of the release of DNA 1 and the digestion of DNA 2 continues. Since the DNA probes may absorb hexaammineruthenium(III) chloride, the electrochemical species, and the removal of the DNA 2 strand from the electrode surface will result in the decrease of the detected electrochemical signal, which is initially activated by AP, an electrochemical biosensor to assay the activity of AP is proposed in this work. This method may have a linear detection range from 1 to 20 unit/mL with a detection limit of 0.1 unit/mL, and the detection of the enzymatic activity in complex biological fluids can also be realized.  相似文献   

12.
A simple electrochemical biosensor was developed for the detection of the mitochondrial NADH dehydrogenase 6 gene (MT-ND6) and its enzymatic digestion by BamHI enzyme. This biosensor was fabricated by modification of a glassy carbon electrode with gold nanoparticles (AuNPs/GCE) and a probe oligonucleotide (ssDNA/AuNPs/GCE). The probe, which is a thiolated segment of the MT-ND6 gene, was deposited by self-assembling immobilization on AuNPs/GCE. Two indicators including methylene blue (MB) and neutral red (NR) were used as the electroactive indicators and the electrochemical response of the modified electrode was measured by differential pulse voltammetry. The proposed biosensor can detect the complementary sequences of the MT-ND6 gene. Also the modified electrode was used for the detection of an enzymatic digestion process by BamHI enzyme. The electrochemical biosensor can detect the MT-ND6 gene and its enzymatic digestion in polymerase chain reaction (PCR)-amplified DNA extracted from human blood. Also the biosensor was used directly for detection of the MT-ND6 gene in all of the human genome.  相似文献   

13.
We have designed a simple and novel electrochemical biosensor based on glassy carbon electrode (GCE) for DNA detection. GCE was modified with reduced graphene oxide (RGO) and gold nanoparticles (AuNPs) by the electrochemical method, which is helpful for immobilization of thiolated bioreceptors. The electrode modification processes were characterized by scanning electron microscopy (SEM) and electrochemical methods. Then a single-stranded DNA (ssDNA) probe for BRCA1 5382 insC mutation detection was immobilized on the modified electrode for a specific time. The experimental conditions, such as probe immobilization time and target DNA (complementary DNA) hybridization time and temperature with probe DNA, were optimized using electrochemical methods. The electrochemical response for DNA hybridization and synthesis was measured using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) methods. The calibration graph contains two linear ranges; the first part is in the range of 3.0 × 10−20 to 1.0 × 10−12 M, and the second segment part is in the range of 1.0 × 10−12 to 1.0 × 10−7 M. The biosensor showed excellent selectivity for the detection of the complementary sequences from noncomplementary sequences, so it can be used for detection of breast cancer.  相似文献   

14.
An electrochemical detection method for chemical sensing has been developed using a DNA aptamer immobilized gold electrode chip. DNA aptamers specifically binding to 17beta-estradiol were selected by the SELEX (Systematic Evolution of Ligands by EXponential enrichment) process from a random ssDNA library, composed of approximately 7.2 x 10(14) DNA molecules. Gold electrode chips were employed to evaluate the electrochemical signals generated from interactions between the aptamers and the target molecules. The DNA aptamer immobilization on the gold electrode was based on the avidin-biotin interaction. The cyclic voltametry (CV) and square wave voltametry (SWV) values were measured to evaluate the chemical binding to aptamer. When 17beta-estradiol interacted with the DNA aptamer, the current decreased due to the interference of bound 17beta-estradiol with the electron flow produced by a redox reaction between ferrocyanide and ferricyanide. In the negative control experiments, the current decreased only mildly due to the presence of other chemicals.  相似文献   

15.
We demonstrate a novel protocol for sensitive in situ label-free electrochemical detection of DNA hybridization based on copper complex ([Cu(phen)2]2+, where phen = 1,10-phenanthroline) and graphene (GR) modified glassy carbon electrode. Here, [Cu(phen)2]2+ acted advantageously as both the electrochemical indicator and the anchor for probe DNA immobilization via intercalative interactions between the partial double helix structure of probe DNA and the vertical aromatic groups of phen. GR provided large density of docking site for probe DNA immobilization and increased the electrical conductivity ability of the electrode. The modification procedure was monitored by electrochemical impedance spectroscopy (EIS). Square-wave voltammetry (SWV) was used to explore the hybridization events. Under the optimal conditions, the designed electrochemical DNA biosensor could effectively distinguish different mismatch degrees of complementary DNA from one-base mismatch to noncomplementary, indicating that the biosensor had high selectivity. It also exhibited a reasonable linear relationship. The oxidation peak currents of [Cu(phen)2]2+ were linear with the logarithm of the concentrations of complementary target DNA ranging from 1 × 10−12 to 1 × 10−6 M with a detection limit of 1.99 × 10−13 M (signal/noise = 3). Moreover, the stability of the electrochemical DNA biosensor was also studied.  相似文献   

16.
Combining the advantages of signal-on strategy and nicking endonuclease assisted electrochemistry signal amplification (NEAESA), a new sensitive and signal-on electrochemical DNA biosensor for the sequence specific DNA detection based on NEAESA has been developed for the first time. A Hairpin-shape probe (HP), containing the target DNA recognition sequence, is thiol-modified at 5' end and immobilized on gold electrode via Au-S bonding. Subsequently, the HP modified electrode is hybridized with target DNA to form a duplex. Then the nicking endonuclease is added and nicks the HP strand in the duplex. After nicking, 3'-ferrocene (Fc)-labeled part complementary probe (Fc-PCP) is introduced on the electrode surface by hybridizing with the thiol-modified HP fragment, which results in the generation of electrochemical signal. Hence, the DNA biosensor is constructed successfully. The present DNA biosensor shows a wide linear range of 5.0×10(-13)-5.0×10(-8)M for detecting target DNA, with a low detection limit of 0.167pM. The proposed strategy does not require any amplifying labels (enzymes, DNAzymes, nanoparticles, etc.) for biorecognition events, which avoids false-positive results to occur frequently. Moreover, the strategy has the benefits of simple preparation, convenient operation, good selectivity, and high sensitivity. With the advantages mentioned above, this simple and sensitive strategy has the potential to be integrated in portable, low cost and simplified devices for diagnostic applications.  相似文献   

17.
A novel electrochemical biosensor was developed for detecting short DNA oligonucleotide of Bacillus thuringiensis (Bt) transgenic sequence based on Ag nanoparticle aggregates. To fabricate this DNA biosensor, the thiol-modified capture DNA (cDNA) was first anchored on gold (Au) electrode, and then the target DNA (tDNA) was hybridized with the immobilized cDNA. Subsequently, the probe DNA (pDNA) functionalized by biotinylated Ag nanoparticle was associated with the fixed tDNA, and the single Ag nanoparticle label was obtained (cited as SAg label). Finally, dissociative biotinylated Ag nanoparticle was bound to the resultant biotinylated SAg label assembled on Au electrode by virtue of bridge molecule streptavidin (SA) through biotin-SA specific interaction, which could lead to in situ aggregate of Ag nanoparticles on Au electrode and induce a novel tag including multiple Ag nanoparticles (cited as MAg tag). The novel tag exhibited excellent electroactive property in the solid-state Ag/AgCl process and was successfully applied to Bt transgenic sequence assay. A detection limit of 10 fM was achieved, which was improved by three orders of magnitude as compared to the SAg label. Furthermore, this novel DNA biosensor demonstrated a good selectivity towards tDNA.  相似文献   

18.
In this study, an enzyme-amplified electrochemical biosensor was developed for detection of the promyelocytic leukemia/retinoic acid receptor alpha (PML/RARα) fusion gene in acute promyelocytic leukemia (APL). This new sensor employs a hairpin locked nucleic acids (LNAs) probe dually labeled with biotin and carboxyfluorescein molecule (FAM). The probe is immobilized at a streptavidin-modified electrode surface via the biotin-streptavidin bridge, and FAM serves as an affinity tag for the peroxidase conjugate binding. Initially, the immobilized hairpin probe was in the "closed" state in the absence of the target, which shielded FAM from being approached by the bulky anti-FAM-HRP conjugate due to the steric effect. Target binding opens the hairpin structure of the probe, the probe undergoes a significant conformational change, forcing FAM away from the electrode. As a result, the FAM label becomes accessible by the anti-FAM-HRP, and the target hybridization event can be sensitively transduced via the enzymatically amplified electrochemical current signal. This new biosensor demonstrates its excellent specificity for single-base mismatch and able to detect as little as 83 fM target DNA even in the presence of human serum. We also employed this sensor to directly detect PCR real sample with satisfactory results.  相似文献   

19.
A disposable electrochemical biosensor for the detection of DNA sequences related to the human cytomegalovirus (HCMV) is described. The sensor relies on the adsorption of an amplified human cytomegalovirus DNA strand onto the sensing surface of a screen-printed carbon electrode, and to its hybridization to a complementary single-stranded biotinylated DNA probe. The extent of hybrids formed was determined with streptavidin conjugated to horseradish peroxidase. The peroxidase label was indirectly quantified by measuring the amount of the chromophore and electroactive product 2,2'-diaminoazobenzene generated from the o-phenylenediamine substrate. The intensity of differential pulse voltammetric peak currents resulting from the reduction of the enzyme-generated product was related to the number of target HCMV-amplified DNA molecules present in the sample, and the results were compared to those obtained with standard methods, i.e., agarose gel electrophoresis quantification and colorimetric hybridization assay in a microtiter plate. A detection limit of 0.6 amol/ml of HCMV-amplified DNA fragment was obtained with the electrochemical DNA biosensor. The electrochemical method was 23,000-fold more sensitive than the gel electrophoresis technique and 83-fold more sensitive than the colorimetric hybridization assay in a microtiter plate.  相似文献   

20.
A new electrochemical DNA biosensor for bovine papillomavirus (BPV) detection that was based on screen-printed electrodes was comprehensively studied by electrochemical methods of cyclic voltammetry (CV) and differential pulse voltammetry (DPV). A BPV probe was immobilised on a working electrode (gold) modified with a polymeric film of poly-L-lysine (PLL) and chitosan. The experimental design was carried out to evaluate the influence of polymers, probe concentration (BPV probe) and immobilisation time on the electrochemical reduction of methylene blue (MB). The polymer poly-L-lysine (PLL), a probe concentration of 1μM and an immobilisation time of 60min showed the best result for the BPV probe immobilisation. With the hybridisation of a complementary target sequence (BPV target), the electrochemical signal decreased compared to a BPV probe immobilised on the modified PLL-gold electrode. Viral DNA that was extracted from cattle with papillomatosis also showed a decrease in the MB electrochemical reduction, which suggested that the decreased electrochemical signal corresponded to a bovine papillomavirus infection. The hybridisation specificity experiments further indicated that the biosensor could discriminate the complementary sequence from the non-complementary sequence. Thus, the results showed that the development of analytical devices, such as a biosensor, could assist in the rapid and efficient detection of bovine papillomavirus DNA and help in the prevention and treatment of papillomatosis in cattle.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号