首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A total of 1245 women had a copper 7 intrauterine contraceptive device (IUD) inserted in 1971-3 were followed up for three years (22 761-5 women months of use). After 24 months 483 women elected to continue with the same copper 7 (continuation group), and 183 had their copper 7 replaced with a new one (replacement group). The subsequent pregnancy and expulsion rates were both significantly lower in the replacement group. The higher pregnancy rate among the women who continued to use their copper 7 device for a third year suggests that although the copper is still there, it is not available for contraceptive action. Replacing the device at 24 months did not seem to cause again the problems that usually occur in the first six months of IUD use.  相似文献   

2.
Activities of Phosphorylase, glyceraldehyde-3 -phosphate dehydrogenase, lactate dehydrogenase, malate dehydrogenase and succinate dehydrogenase in the rat endometrial tissue are significantly inhibited by an intrauterine copper device, while it stimulated glucose-6-phosphate dehydrogenase activity. The copper device decreased the lactate/pyruvate ratio in the tissue; pyruvate utilizationin vitro by the rat endometrium is also blocked by copper. These findings suggested that the normal carbohydrate metabolism of the tissue may be affected in presence of copper, thus resulting in a change of the endometrial function, which may be one of the factors responsible for the contraceptive and pharmacological action of an intrauterine copper device.  相似文献   

3.
Copper-bearing intrauterine contraceptive devices (IUDs) removed after various times in utero were examined by scanning electron microscopy and x-ray microanalysis of the elements present. As time in utero increased these devices became increasingly calcified. This calcification may limit the release of copper from the devices and decrease the specific contraceptive effectiveness of copper over an enert plastic device. Conversely, any teratogenic effects attributable to the copper may decrease with time in utero and depend on the extent of calcification. Even though the amount of copper in the device is not significantly diminished after two years, devices should not remain in situ for over two years because calcium accumulation probably prevents further diffusion of copper. Calcification can begin as early as six months after insertion. Consequently a careful review of the amount of time a copper-containing IUD should be left in situ should be undertaken.  相似文献   

4.
A detailed analysis was undertaken of reports of possible pelvic infection in relation to the use of four commonly fitted intrauterine contraceptive devices during 1971 to 1978 in the United Kingdom. The four devices were the Dalkon shield, Lippes loops 3C and 2D, and the Gravigard (copper 7), and data used were those collected systematically through the UK intrauterine device research network. Prospective reports that the Dalkon shield was uniquely related to high levels of infection when compared with other intrauterine devices were not substantiated in this prospective study among 13 349 users. Though some factors such as social class and previous experience of abortion appeared to influence the rate of infection, the type of intrauterine device being worn did not appear to be a significant factor. Various methods of analysis were used including life table, regression, and discriminant analysis, using information relating to the type of intrauterine device worn, the characteristics of the user, the fitting centre, and the pattern of diagnosis and treatment of reported or suspected pelvic infection. The results of this study suggest that fears that the Dalkon shield may be associated with a higher incidence of pelvic infection than other intrauterine devices may have been unjustified.  相似文献   

5.
Cervical smears from 1,784 women who attended the family planning clinics of the Institute for Research in Reproduction were examined for the presence of Actinomyces-like organisms. Among 815 intrauterine contraceptive device (IUD) users, the repeat smears from 57 women were positive for Actinomyces-like organisms, giving a prevalence rate of 6.99%. Immunofluorescent staining using specific antisera confirmed the presence of A. israelii in all 57 women. Forty IUD users whose smears were positive for Actinomyces-like organisms underwent bacteriologic culture studies; A. israelii was isolated in 23 of these cases. The clinical findings at the time of smear collection in the 57 IUD users were within normal limits. The initial cervical smears of all IUD users and both the initial and repeat smears of all nonusers were negative for Actinomyces-like organisms. The data indicate that prolonged use (greater than 2 years) of an inert or copper intrauterine device promotes the overgrowth of Actinomyces in the vagina and that this can be detected by routine cervical cytology.  相似文献   

6.
B. N. Barwin  S. Tuttle  E. E. Jolly 《CMAJ》1978,118(1):53-58
This presentation brings into perspective the most recent information on intrauterine contraceptive devices. A comprehensive review of the literature is presented in a manner meaningful to the clinician. The advantages and disadvantages of this method of contraception, the problems that arise and the recommended methods of management are discussed. An updated review of the literature with regard to bleeding, pain, expulsion of the device, infection, uterine perforation and pregnancy is also presented.  相似文献   

7.
摘要 目的:探讨宫内节育器与宫腔支撑球囊联合应用治疗中重度宫腔粘连的临床效果。方法:选择2016年12月至2019年8月于西安交通大学第一附属医院宫腔镜诊疗中心接受宫腔镜下中重度宫腔粘连分解术的患者共96例,采用随机对照表法将其分为两组。对照组48例,术后宫腔内放置宫内节育器(intrauterine contraceptive device,IUD);研究组48例,术后放置宫腔支撑球囊(intrauterine support balloon,ISB),3~5 d后更换为宫内节育器。两组术后均给予为期3月的人工周期治疗。术后1月,复查宫腔镜了解宫腔有无再粘连并取出宫内节育器,以此评估手术效果是否有效,术后3月时随访其月经来潮情况。统计比较两组术后5 d内阴道出血量、C反应蛋白水平、发热、下腹痛以及节育器或支持球囊有无脱落等情况,术后1月手术效果及术后3月月经恢复情况。结果:研究组的手术有效率及月经改善比例均显著高于对照组(P<0.05),术后5 d内阴道出血量显著少于对照组(P<0.05);下腹痛及球囊脱落事件发生率显著低于对照组(P<0.05)。两组在C反应蛋白水平、发热发生率对比无统计学差异(P>0.05)。结论:与单独使用宫内节育器相比,联合使用宫腔支撑球囊能提高中重度宫腔粘连分解手术有效率,改善月经,减少术后出血,不增加感染风险,但球囊易于脱落且会增加患者下腹疼痛。  相似文献   

8.
Cervical smears from 293 users of intrauterine contraceptive devices attending family planning clinics in East Fife, Dundee, and Angus were stained by Papanicolaou and Gram''s methods and examined for actinomyces-like organisms. Of the 128 women using plastic devices, 40 gave smears positive for these organisms. In contrast only two positive smears were obtained from the 165 women using devices containing copper and none from a control group of 300 women taking oral contraceptives. Colonisation was more common in women whose plastic devices had been in situ for over two years. Correlations between the presence of these organisms and recorded incidences of pain and both clinical and cytological evidence of inflammation of the lower genital tract were highly significant (p = 0.00001, p < 0.00001, and p < 0.00001 respectively). The results suggest that plastic intrauterine contraceptive devices predispose to colonisation by actinomyces-like organisms, particularly after long-term use. Hence if the apparently bacteriostatic action of copper devices is confirmed these should probably be more widely used.  相似文献   

9.
There has been renewed interest in recent years in the use of intrauterine devices for contraception. The Margulies intrauterine device was inserted in 303 patients. Of 301 patients subsequently evaluated, 24 expelled the device spontaneously; in 21 others the device was removed for various reasons. No pregnancies occurred in the first 920 patient-months. There were no serious complications in the patients using the coil. From this experience we estimate that not more than 80% of patients will accept this technique. Intrauterine contraceptive devices are, however, a satisfactory addition to the various methods of birth control.  相似文献   

10.
The perceptions and values of a sample of 106 women towards four contraceptive methods (oral contraceptives, intrauterine device, diaphragm and foam-and-condoms) were evaluated in the light of 24 identified issues of concern. The choice of a contraceptive method appears to represent a trade-off among negatively valued outcomes—the “best” method being least likely to incur undesirable consequences.  相似文献   

11.
86例绝经后妇女取宫内节育器分析   总被引:1,自引:0,他引:1  
目的探讨提高绝经后妇女取宫内节育器(IUD)的成功率,减少绝经后取器并发症发生的有效方法。方法对86例绝经后妇女取器者术前给予米非司酮25mg,每12h 1次,连续口服3天,服药前后2h禁食,第4天空腹口服米索前列醇600μg后2h取器。结果顺利取出IUD者59例,用宫颈扩张器扩张宫口为6号后顺利取出者23例;IUD嵌顿者4例,1例最终通过宫腔镜取器,余3例由宫颈扩宫器扩至6号后剪断不锈钢丝后取出。所有取器者术中腹痛和出血量正常,术后阴道出血2~5天。结论米非司酮联合米索前列醇在绝经后妇女取宫内节育器应用中,可有效扩张、软化宫颈,具有安全、有效的特点,值得基层推广。  相似文献   

12.
ABSTRACT: BACKGROUND: We describe the rationale and protocol for a randomized noninferiority controlled trial (RCT) to determine if the Flexi-T380(+) copper intrauterine contraceptive device (IUD) is comparable in terms of effectiveness and expulsion rates to the most common Canadian IUD currently in use, NovaT-200, when placed immediately after a first-trimester abortion. METHODS: Consenting women choosing to use an IUD after an abortion for a pregnancy of less than 12 weeks of gestation will be randomized to device-type groups to receive immediate post-abortion placement of either a Flexi-T380(+) IUD, a device for which no current evidence on expulsion or effectiveness rates is available, or the Nova-T200 IUD, the only other brand of copper IUD available in Canada at the time of study initiation. The primary outcome measure is IUD expulsion rate at 1 year. Secondary outcomes include: pregnancy rate, method continuation rate, complication rates (infection, perforation), and satisfaction with contraceptive method. A non-intervention group of consenting women choosing a range of other post-abortion contraception methods, including no contraception, will be included for comparison of secondary outcomes. Web-based contraception satisfaction questionnaires, clinical records, and government-linked health administrative databases will be used to assess primary and secondary outcomes. DISCUSSION: The RCT design, combined with access to clinical records at all provincial abortion clinics, and to information in provincial single-payer linked administrative health databases, birth registry, and hospital records, offers a unique opportunity to determine if a novel IUD has a comparable expulsion rate to that of the current standard IUD in Canada, in addition to the first opportunity to determine pregnancy rate and method satisfaction at 1 year post-abortion for women choosing a range of post-abortion contraceptive options. We highlight considerations of design, implementation, and evaluation of the first trial to provide rigorous evidence for the effectiveness of current Canadian IUDs when inserted after first-trimester abortion.Trial registrationClinicalTrials.gov Identifier NCT01174225.  相似文献   

13.
J. W. Sellors 《CMAJ》1981,125(7):717-720
Over a 5-year period a family practitioner inserted copper-7 (Cu-7 intrauterine contraceptive devices (IUDs) in 134 women. The rates of continued use after 2 years, 53.0% for the women''s first IUD and 63.9% for all their IUDs, and of accidental pregnancy, 2.4%, are comparable to those in the literature. However, in this series the rate of expulsion was 0.8%, much lower than that in the literature. Fertility did not appear to be reduced in women who planned to have pregnancies after the device was removed. A carefully scrutinized technique of insertion and conscientious follow-up make the Cu-7 IUD an acceptable form of contraception for many patients in a family practice.  相似文献   

14.
Elsayed S  George A  Zhang K 《Anaerobe》2006,12(2):67-70
We report a case of intrauterine contraceptive device (IUD) associated pelvic actinomycosis due to Actinomyces urogenitalis in a previously healthy young adult woman. Diagnosis was confirmed by 16S ribosomal RNA gene sequencing of bacterial colonies growing from the extracted device. This is the first documented report of human infection caused by this micro-organism.  相似文献   

15.
Copper and zinc inhibit the metabolism of prostaglandin by the human uterus   总被引:1,自引:0,他引:1  
Prostaglandins (PGs) have often been cited as intermediates in the action of the inert and copper-bearing intrauterine contraceptive device (IUD). Although investigations have shown an effect of copper at high (approx. 1 x 10(-4) mol/l) concentrations on PG synthesis, little consideration has been given to the possible effects of copper on PG metabolism. In this study the effect of copper and zinc ions on PG metabolism by human endometrium and myometrium has been investigated using radiolabel techniques together with gas chromatography mass spectrometry (GCMS) measurements of metabolites of PGE2. These experiments showed that concentration of 1 X 10(-5) mol/l of copper and zinc were sufficient to inhibit significantly (P less than 0.01) PGE metabolism. These levels of copper are within the physiological range of levels thought to be present in the uterine tissue and fluid of wearers of the copper-containing IUD and the inhibition of PG metabolism in these women might account for the small but significant decrease in the length of the luteal phase of their menstrual cycles.  相似文献   

16.
A case of pelvic abscess caused by Actinomyces in a patient wearing an intrauterine contraceptive device is presented. The diagnosis was established preoperatively by transvaginal fine needle aspiration. The cytologic, surgical and histologic findings are discussed.  相似文献   

17.
Preliminary acceptability and reliability tests of the Dalkon Shield were done in 377 women over 17 months, amounting to 3,028 months of use. There was a 98% follow-up. The pregnancy rate of 4·7 and expulsion rate of 6·3 do not meet the claims described in initial trials by the developers of the device. Nevertheless, the Dalkon Shield seems to be an advance in intrauterine contraception since it has the advantages of a lower expulsion rate than the “first generation” inert intrauterine devices.  相似文献   

18.
The return of the pharmaceutical industry to the market of contraception   总被引:1,自引:0,他引:1  
Johansson ED 《Steroids》2000,65(10-11):709-711
In the 1980s and 1990s, the litigious climate in the US had a catastrophic effect on sales of many major contraceptives. Although oral contraceptives escaped controversy, the intrauterine device (IUD) and Norplant(R) were two targets of damaging litigation. The IUD was withdrawn from the market in 1985. Since 1994 when the attacks began against Norplant, its US sales have dramatically declined, even though no fault has been found in the method or its development. In general, pharmaceutical companies were extremely hesitant to develop new contraceptives during this period. The bleak outlook, however, began to shift in the late 1990s, as fertility rates began to decrease worldwide and contraceptive users increased. By 2025, 2500 million women will comprise the customer base for contraception. Global pharmaceutical companies are now participating in expanding markets overseas and have launched and continue to develop a range of new long-term reversible, and highly effective, contraceptive products outside the traditional oral contraceptive field. Two new contraceptives on the way to the US market are: Mirena, a levonorgestrel-releasing intrauterine system manufactured by Schering-Leiras; and Implanon, a single implant system manufactured by Organon of the Netherlands. Other birth control methods soon to be launched include: emergency contraceptives, the contraceptive patch, monthly contraceptive injections, mifepristone for medical abortion, and modified oral contraceptives.  相似文献   

19.
A patient wearing an intrauterine contraceptive device (IUD) was diagnosed as being colonized by Actinomyces and amoebae by examination of a routine Papanicolaou smear. The patient received vaginal treatment with metronidazole, which temporarily eliminated the protozoa; however, it was necessary to remove the IUD to definitively eradicate the microorganisms. Follow-up Papanicolaou smears taken after removal of the IUD have been normal and free of both microorganisms.  相似文献   

20.
M. Smith  B. N. Barwin 《CMAJ》1983,129(7):699-701,710
The alleged adverse effects of oral contraceptives and intrauterine devices have led to increased consumer and physician demand for vaginal contraceptive devices. The efficacy and the advantages and disadvantages of vaginal sponges, cervical caps and diaphragms are discussed and compared in this article.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号