首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The suitability of the quartz crystal microbalance (QCM) technique for monitoring the attachment and spreading of mammalian cells has recently been established. Different cell species were shown to generate an individual response of the QCM when they make contact with the resonator surface. Little is known, however, about the underlying mechanisms that determine the QCM signal for a particular cell type. Here we describe our results for different experimental approaches designed to probe the particular contributions of various subcellular compartments to the overall QCM signal. Using AC impedance analysis in a frequency range that closely embraces the resonators' fundamental frequency, we have explored the signal contribution of the extracellular matrix, the actin cytoskeleton, the medium that overlays the cell layer, as well as the liquid compartment that is known to exist between the basal plasma membrane and the culture substrate. Results indicate that the QCM technique is only sensitive to those parts of the cellular body that are involved in cell substrate adhesion and are therefore close to the resonator surface. Because of its noninvasive nature, sensitivity, and time resolution, the QCM is a powerful means of quantitatively studying various aspects of cell-substrate interactions.  相似文献   

2.
Recent applications of quartz crystal resonant sensor technology to monitor cell adhesion and specific ligand interaction processes has triggered the development of a new category of quartz crystal microbalance (QCM) based biosensors. In this study human oral epithelial cells (H376) were cultured on quartz sensors and their response to microspheres investigated in situ using the QCM technique. The results demonstrated that this novel biosensor was able to follow cell-microsphere interactions in real-time and under conditions of flow as would occur in the oral cavity. Unique frequency profiles generated in response to the microspheres were postulated to be due to phases of mass addition and altered cellular rigidity. Supporting microscopic evidence demonstrated that the unique frequency responses obtained to these interactions were in part due to binding between the cell surface and the microspheres. Furthermore, a cellular uptake process, in response to microsphere loading was identified and this, by influencing the rigidity of the cellular cytoskeleton, was also detectable through the frequency responses obtained.  相似文献   

3.
The quartz crystal microbalance (QCM) has been widely accepted as a sensitive technique to follow adsorption processes in gas as well as in liquid environments. However, there are only a few reports about the use of this technique to monitor the attachment and spreading of mammalian cells onto a solid support in culture. Using a QCM-setup we investigated the time course of cell attachment and spreading as a function of seeding density for three widespread and frequently used cell lines (MDCK strains I and II and Swiss 3T3-fibroblasts). Results were found to be in good agreement with the geometrical properties of the individual cell types. The shifts of the resonance frequency associated with confluent cell layers on top of the quartz resonators were found to be dependent on the cell species [MDCK-I: (320±20) Hz; MDCK-II: (530±25) Hz; 3T3: (240±15) Hz] reflecting their individual influence on the shear oscillation of the resonator. These findings are discussed with respect to the basic models of materials in contact with an oscillating quartz resonator. We furthermore showed by inhibition-assays using soluble RGD-related peptides, that only specific, integrin mediated cell adhesion is detected using this QCM approach, whereas the sole presence of the cellular body in close vicinity to the resonator surface is barely detectable.  相似文献   

4.
The quartz crystal microbalance (QCM) was used to monitor specific, integrin-mediated adhesion of human ovarian cancer cells to distinct extracellular matrix (ECM) proteins immobilized on gold-coated quartz crystal resonators. The QCM was operated in the impedance analysis mode, where frequency shift as well as bandwidth are accessible on a broad range of overtones. The increase in bandwidth caused by covering the quartz resonator with cells was reproducible and largely independent of overtone order, whereas the frequency shift displayed some variability. Thus the bandwidth proved to be the more robust parameter for sensing cell adhesive events. The bandwidth increased in proportion to the number of seeded cells to the quartz crystal as long as the number was below 150,000 cells/ml. Comparing the resonance parameters on different harmonics, one finds that viscoelastic modeling with homogeneous layer systems cannot reproduce the results: lateral heterogeneity has to be taken into account. The differences in adhesive strength of human ovarian cancer cells towards selected ECM proteins monitored by QCM was in good agreement with data obtained by conventional cell adhesion assays. Strong cell adhesion was observed to the ECM proteins vitronectin (VN) and fibronectin (FN), while only weak attachment occurred on laminin. In order to prove specific, integrin alphavbeta3-mediated cell adhesion to its ligands FN and VN, the cyclic integrin alphavbeta3-directed peptide c(RGDfV) was used as competitor and significantly reversed cell adhesion. Since integrin interaction with ECM proteins is dependent on the presence of bivalent cations, cell detachment was also seen after treatment of cell monolayers with the chelator ethylene-dinitro-tetra-acetic acid (EDTA). The QCM technique is a reliable method to monitor cell adsorption to ECM-pretreated surfaces in real time. It may be an alternative tool for screening specific and selective antagonists of integrin/ECM interaction.  相似文献   

5.
Epidermal growth factor (EGF)-induced cell de-adhesion has been implicated as a critical step of normal embryonic development, wound repair, inflammatory response, and tumor cell metastasis. Like many other cellular processes, this cell de-adhesion exhibits a complex, time-dependent pattern. A comprehensive understanding of this process requires a quantitative, real-time assessment of cell-substrate interactions at the molecular level. We employed the quartz crystal microbalance with dissipation monitoring (QCM-D) to successfully track the EGF-induced changes in energy dissipation factor, ΔD, of a monolayer of MCF10A cells in real time. This time-dependent ΔD response correlates well both qualitatively and quantitatively with sequential events of a rapid disassembly, transition, and slow reassembly of focal adhesions of the cells in response to EGF exposure. Based on this strong correlation, we utilized the QCM-D to demonstrate that this dynamic focal-adhesion restructuring is regulated temporally by the downstream pathways of EGFR signaling such as the PI3K, MAPK/ERK, and PLC pathways. Because the QCM-D is a noninvasive technique, this novel approach potentially has a broad range of applications in the fundamental study of cellular processes, such as cell signaling and trafficking and mechanotransduction, and holds promise for drug and biomarker screening.  相似文献   

6.
Fluid shear and other mechanical forces play an important role in the normal biophysical, biochemical, and gene regulatory responses of vertebrate tissue that are reflected in the expression of normal cell differentiation, growth, and function. Despite some promising work reported on the application of the quartz crystal microbalance (QCM) to both prokaryote and eukaryote cells over the last decade, QCM has yet to be successfully applied to cells in culture under conditions of flow-induced shear. In this study, high sensitivity QCM in conjunction with fluid modelling was used to monitor the onset of senescence in immortalised human embryonic kidney cells under laminar shear stresses of between 0.04 and 335 dyne/cm(2). The feasibility of this approach as a means of quantification and characterisation of cell physiological response and adhesion are explored and discussed.  相似文献   

7.
A novel approach to the study of molecular interactions on the surface of mammalian cells using a QCM biosensor was developed. For this study, an epidermoid carcinoma cell line (A-431) and a breast adenocarcinoma cell line (MDA-MB-468) were immobilized onto polystyrene-coated quartz crystals. The binding and dissociation between the lectin Con A and the cells as well as the inhibition of the binding by monosaccharides were monitored in real time and provided an insight into the complex avidic recognition of cell glycoconjugates. The real-time lectin screening of a range of lectins, including Con A, DBA, PNA and UEA-I, enabled the accurate study of the glycosylation changes between cells, such as changes associated with cancer progression and development. Furthermore, the kinetic parameters of the interaction of Con A with MDA-MB-468 cells were studied. This application provides investigators in the field of glycobiology with a novel tool to study cell surface glycosylation and may also have impacts on drug discovery.  相似文献   

8.
A novel quartz crystal microbalance (QCM) technique was used to study the adhesion of nonfimbriated and fimbriated Escherichia coli mutant strains to hydrophilic and hydrophobic surfaces at different ionic strengths. This technique enabled us to measure both frequency shifts (Deltaf), i.e., the increase in mass on the surface, and dissipation shifts (DeltaD), i.e., the viscoelastic energy losses on the surface. Changes in the parameters measured by the extended QCM technique reflect the dynamic character of the adhesion process. We were able to show clear differences in the viscoelastic behavior of fimbriated and nonfimbriated cells attached to surfaces. The interactions between bacterial cells and quartz crystal surfaces at various ionic strengths followed different trends, depending on the cell surface structures in direct contact with the surface. While Deltaf and DeltaD per attached cell increased for nonfimbriated cells with increasing ionic strengths (particularly on hydrophobic surfaces), the adhesion of the fimbriated strain caused only low-level frequency and dissipation shifts on both kinds of surfaces at all ionic strengths tested. We propose that nonfimbriated cells may get better contact with increasing ionic strengths due to an increased area of contact between the cell and the surface, whereas fimbriated cells seem to have a flexible contact with the surface at all ionic strengths tested. The area of contact between fimbriated cells and the surface does not increase with increasing ionic strengths, but on hydrophobic surfaces each contact point seems to contribute relatively more to the total energy loss. Independent of ionic strength, attached cells undergo time-dependent interactions with the surface leading to increased contact area and viscoelastic losses per cell, which may be due to the establishment of a more intimate contact between the cell and the surface. Hence, the extended QCM technique provides new qualitative information about the direct contact of bacterial cells to surfaces and the adhesion mechanisms involved.  相似文献   

9.
The quartz crystal microbalance (QCM) was used to monitor endothelial cell (EC) adhesion on the gold surface of an oscillating quartz crystal contained in a QCM device. A number of parameters were investigated. First, we observed differential QCM O-ring toxicities for ECs. Second, appropriate conditions for cell culture and QCM cell environment were identified that can eliminate large-scale frequency oscillations in the measurements. These artifacts are not due to added cells but originate in the time-dependent evaporation of water. Having eliminated these artifacts, we then demonstrated that the measured steady-state crystal frequency shift, Delta f, and motional resistance shift, DeltaR, were determined by the number of firmly attached ECs requiring trypsinization from the crystal surface. Last, following steady-state attachment of ECs, the EC growth stimulation by fibroblast growth factor was monitored in a continuous fashion by measuring f and R values over a 72 h. period. We observed the Delta f values to increase in a way that reflected the increase in EC number bound to the QCM surface. Following addition of ECs to the QCM, the time-dependent increase in DeltaR can be interpreted in terms of increase by the ECs of the energy dissipation properties of the solution at the solution-gold surface interface. This effect is due to their rapid surface attachment and the elaboration of their cytoskeletal properties. These results indicate that the QCM technique can be used for the study of EC attachment and growth and suggest its potential for the real time study of per unit surface area cell mass distribution dynamics and viscoelastic properties and the cells' responses to stresses or perturbations brought about using biologically active molecules.  相似文献   

10.
Marx KA 《Biomacromolecules》2003,4(5):1099-1120
The quartz crystal microbalance (QCM) is a simple, cost effective, high-resolution mass sensing technique, based upon the piezoelectric effect. As a methodology, the QCM evolved a solution measurement capability in largely analytical chemistry and electrochemistry applications due to its sensitive solution-surface interface measurement capability. The technique possesses a wide detection range. At the low mass end, it can detect monolayer surface coverage by small molecules or polymer films. At the upper end, it is capable of detecting much larger masses bound to the surface. These can be complex arrays of biopolymers and biomacromolecules, even whole cells. In addition, the QCM can provide information about the energy dissipating properties of the bound surface mass. Another important and unique feature of the technique is the ability to measure mass and energy dissipation properties of films while simultaneously carrying out electrochemistry on solution species or upon film systems bound to the upper electrode on the oscillating quartz crystal surface. These measurements can describe the course of electropolymerization of a film or can reveal ion or solute transport within a film during changes in the film environment or state, including the oxidation state for an electroactive film driven by the underlying surface potential. The past decade has witnessed an explosive growth in the application of the QCM technique to the study of a wide range of molecular systems at the solution-surface interface, in particular, biopolymer and biochemical systems. In this report, we start with a brief historical and technical overview. Then we discuss the application of the QCM technique to measurements involving micellar systems, self-assembling monolayers and their phase transition behavior, molecularly imprinted polymers, chemical sensors, films formed using the layer-by-layer assembly technique, and biopolymer films and point out the utility of the electrochemical capabilities of the technique to characterizing film properties, especially electroactive polymer films. We also describe the wide range of surface chemistries and attachment strategies used by investigators to bring about surface attachment and multi-layer interactions of these thin film systems. Next we review the wide range of recent applications of the technique to: studies of complex biochemical and biomimetic systems, the creation of protein and nucleic acid biosensors, studies of attached living cells and whole cell biosensor applications. Finally, we discuss future technical directions and applications of the QCM technique to areas such as drug discovery.  相似文献   

11.
For investigating effects of chemical stressors to cultured cells, we have developed a quartz crystal microbalance (QCM) system with a micro CCD camera that enables microscopic observations simultaneously with the QCM measurements. Human hepatoma cell line (HepG2) cells were cultured on the collagen coated quartz crystal which has indium tin oxide (ITO) electrodes that enable transmission imaging of the cultured cells by the micro CCD camera during the QCM measurements. Glutaraldehyde (GA) and t-butylhydroperoxide (t-BHP) were used for the chemical stressors. The response of the QCM was monitored and analyzed with the resonance frequency and the resonance resistance (F-R) diagram. At the same time, the photographs of the cells were recorded to observe the morphological change. In the case of GA, the QCM responded in two steps which consisted of the rapid response of the cross-linking reactions and successive decreasing cytoskeletons in the cells. In the case of t-BHP, the response showed two steps. At first, the cells changed their shapes to round, and then the weakened cells were unsticked from the surface.  相似文献   

12.
In recent years, there has been a rapid growth in the number of scientific reports in which the quartz crystal microbalance (QCM) technique has played a key role in elucidating various aspects of biological materials and their interactions. This article illustrates some key advances in the development of a special variation of this technique called quartz crystal microbalance with dissipation monitoring (QCM-D). The main feature and advantage of QCM-D, compared with the conventional QCM, is that it in addition to measuring changes in resonant frequency (Δf), a simultaneous parameter related to the energy loss or dissipation (ΔD) of the system is also measured. Δf essentially measures changes in the mass attached to the sensor surface, while ΔD measures properties related to the viscoelastic properties of the adlayer. Thus, QCM-D measures two totally independent properties of the adlayer. The focus of this review is an overview of the QCM-D technology and highlights of recent applications. Specifically, recent applications dealing with DNA, proteins, lipids, and cells will be detailed. This is not intended as a comprehensive review of all possible applications of the QCM-D technology, but rather a glimpse into a few highlighted application areas in the biomolecular field that were published in 2007.  相似文献   

13.
In this study we evaluate the strengths and weaknesses of surface plasmon resonance (SPR) spectroscopy and quartz crystal microbalance (QCM) technique for studying DNA assembly and hybridization reactions. Specifically, we apply in parallel an SPR instrument and a 5 MHz QCM device with dissipation monitoring (QCM-D) to monitor the assembly of biotinylated DNA (biotin-DNA) on a streptavidin-modified surface and the subsequent target DNA hybridization. Through the parallel measurements, we demonstrate that SPR is more suitable for quantitative analysis of DNA binding amount, which is essential for interfacial DNA probe density control and for the analysis of its effect on hybridization efficiency and kinetics. Although the QCM is not quantitative to the same extent as SPR (QCM measures the total mass of the bound DNA molecules together with the associated water), the dissipation factor of the QCM provides a qualitative measure of the viscoelastic properties of DNA films and the conformation of the bound DNA molecules. The complexity in mass measurement does not impair QCM's potential for a kinetic evaluation of the hybridization processes. For quantification of target DNA, the biotin-DNA modified SPR and QCM sensors are exposed to target DNA with increasing concentration. The plots of SPR/QCM signals versus target DNA concentration show that water entrapment between DNA strands make the QCM sensitivity for the hybridization assay well comparable with that of the SPR, although the intrinsic mass sensitivity of the 5 MHz QCM is approximately 20 times lower.  相似文献   

14.
This article describes the optimization of an experimental technique referred to as electric cell-substrate impedance sensing (ECIS) to monitor attachment and spreading of mammalian cells quantitatively and in real time. The method is based on measuring changes in AC impedance of small gold-film electrodes deposited on a culture dish and used as growth substrate. Based on experimental data and theoretical considerations we demonstrate that high-frequency capacitance measurements (f = 40 kHz) are most suited to follow the increasing surface coverage of the electrode due to cell spreading. The excellent time resolution of the method allowed an in-depth analysis of cell spreading kinetics under various experimental conditions. Using ECIS we studied the attachment and spreading of epithelial MDCK cells (strain II) on different protein coatings, and investigated the influence of divalent cations on spreading kinetics. We quantified the inhibitory effect of soluble peptides that mimic the recognition sequence of fibronectin and other extracellular matrix proteins (RGDS). We also applied the ECIS technique to monitor the detachment of confluent fibroblastic cell layers (WI38/VA-13) by means of these peptides.  相似文献   

15.
Biocompatibility of polymers is an important parameter for the successful application of polymers in tissue engineering. In this work, quartz crystal microbalance (QCM) devices were used to follow the adhesion of NIH 3T3 fibroblasts to QCM surfaces modified with fibronectin (FN) and poly-D -lysine (PDL). The variations in sensor resonant frequency (Δf) and motional resistance (ΔR), monitored as the sensor signal, revealed that cell adhesion was favored in the PDL-coated QCMs. Fluorescence microscopy images of seeded cells showed more highly spread cells on the PDL substrate, which is consistent with the results of the QCM signals. The sensor signal was shown to be sensitive to extracellular matrix (ECM)-binding motifs. Ethylenediaminetetraacetic acid (EDTA) and soluble Gly-Arg-Gly-Asp-Ser (GRGDS) peptides were used to interfere with cell-ECM binding motifs onto FN-coated QCMs. The acquired acoustic signals successfully showed that in the presence of 30 mM EDTA or 1 mM GRGDS, cell adhesion is almost completely abolished due to the inhibition/blocking of integrin function by these compounds. The results presented here demonstrate the potential of the QCM sensor to study cell adhesion, to monitor the biocompatibility of polymers and materials, and to assess the effect of adhesion modulators. QCM sensors have great potential in tissue engineering applications, as QCM sensors are able to analyze the biocompatibility of surfaces and it has the added advantage of being able to evaluate, in situ and in real time, the effect of specific drugs/treatments on cells.  相似文献   

16.
We report the investigation of biotin-streptavidin binding interactions using microcantilever sensors. A symmetric cantilever construction is employed to minimize the effects of thermal drift and the control of surface chemistry on the backside of the cantilever is demonstrated to reduce the effects of non-specific binding interactions on the cantilever. Three structurally different biotin modified cantilever surfaces are used as a model system to study the binding interaction with streptavidin. The cantilever response to the binding of streptavidin on these biotin sensing monolayers is compared. The lowest detection limit of streptavidin using biotin-HPDP is found to be between 1 and 10nM limited by the optical measurement setup. Surface characterization using quartz crystal microbalance (QCM) and high-resolution atomic force microscope (AFM) is used to benchmark the cantilever sensor response. In addition, the QCM and AFM studies reveal that the surface density of bound streptavidin on biotin modified surfaces was low, thereby implying that effects other than steric hindrance are responsible for defining cantilever response.  相似文献   

17.
We investigate the feasibility of coupling the quartz crystal microbalance (QCM) with magnetic separation for on-line analysis. A flow cell was integrated with QCM and magnetic force for the analysis of magnetic and nonmagnetic samples. The resonant frequency change (Deltaf) of QCM was related to the amount of deposited magnetic nanoparticles. This experiment demonstrates that QCM can be used as an on-line detector for magnetic separation. The QCM also gives a characteristic response of the binding between the streptavidin and biotin labeled on the magnetic nanoparticles. Biotin-labeled magnetic nanoparticles were flowed through a gold electrode of QCM to deposit as a matrix for selective capturing streptavidin. The resonant frequency change of QCM was proportional to the amounts of streptavidin captured by biotin. This technique can provide a simple, economic, and automatic method for on-line detection of biomarkers.  相似文献   

18.
Amphiphilic decyl derivatives of D-tyrosine self-assemble into long rodlike or tubular aggregate structures in aqueous buffered solution. In this report we demonstrate the novel use of the quartz crystal microbalance (QCM) to measure the presence in solution, and subequent enzymatic polymerization, of long rodlike monomer aggregates of the decyl ester of D-tyrosine (DEDT) as a function of their formation and increasing surface binding level as pH values increase from 3 to 7. From these data, using the Sauerbray equation to calculate the effective elastic mass surface binding of deprotonated DEDT aggregates, a pKapp of 8.3 is obtained for the DEDT alpha-NH2 group protonation-deprotonation and subsequent aggregation equilibrium. Furthermore, once aggregates are bound to the QCM surface, we initiate and subsequently monitor enzymatic polymerization of the DEDT monomers by horseradish peroxidase through the measurement of significant changes in the quartz crystal frequency and motional resistance. Following the onset of polymerization, the viscoelastic properties of the bound monomer aggregates change. A final polymerized state is achieved in which the altered physical properties of the polymerized rodlike aggregates make the solution immediately above the QCM surface-solution interface behave as a Newtonian fluid, producing a nearly pure viscosity-density energy dissipative effect on the measured crystal frequency and motional resistance values.  相似文献   

19.
A biofilm reactor was constructed to monitor the long-term growth and removal of biofilms as monitored by the use of a quartz crystal microbalance (QCM) and a novel optical method. The optical method measures the reflectance of white light off the surface of the quartz crystal microbalance electrode (gold) for determination of the biofilm thickness. Biofilm growth of Pseudomonas aeruginosa (PA) on the surface was used as a model system. Bioreactors were monitored for over 6 days. Expressing the QCM data as the ratio of changes in resistance to changes in frequency (DeltaR/Deltaf) facilitated the comparison of individual biofilm reactor runs. The various stages of biofilm growth and adaptation to low nutrients showed consistent characteristic changes in the DeltaR/Deltaf ratio, a parameter that reflects changes in the viscoelastic properties of the biofilm. The utility of white light reflectance for thickness measurements was shown for those stages of biofilm growth when the solution was not turbid due to high numbers of unattached cells. The thickness of the biofilms after 6 days ranged from 48 mum to 68 mum. Removal of the biofilm by a disinfectant (chlorine) was also measured in real time. The combination of QCM and reflectance allowed us to monitor in real time changes in the viscoelastic properties and thickness of biofilms over long periods of time.  相似文献   

20.
The quartz crystal microbalance (QCM) technique has been applied to the real time monitoring of endothelial cell (EC) adhesion and spreading on the QCM gold surface. We previously showed that the measured QCM Deltaf and DeltaR shifts were due to cells adhering to the gold crystal surface, requiring proteolytic enzyme treatment to be removed from the surface, in order for the Deltaf and DeltaR shifts to return to zero. In the present report, we demonstrate the quantitative dependence and saturation of the measured Deltaf and DeltaR shifts on the number of firmly attached ECs as measured by electronic counting of the cells. We demonstrate through a light microscope simulation experiment that the different Deltaf and DeltaR regions of the QCM temporal response curve correspond to the incident ECs contacting the surface, followed by their adhesion and spreading, which reflect cellular mass distribution and cytoskeletal viscoelasticity changes. Also, we demonstrate that the dose response curve of Deltaf and DeltaR values versus attached EC number is more sensitive and possesses less scatter for the hydrophilically treated surface compared to the native gold surface of the QCM. For both surfaces, a Deltaf and DeltaR versus trypsinized, attached EC number plot 1 h post-seeding exhibits a sigmoid curve shape whereas a similar plot 24 h post-seeding exhibits a hyperbolic curve shape. This number dependence suggests cell-cell cooperativity in the initial cell adhesion and spreading processes. These QCM data and our interpretation are corroborated by differences in cell appearance and spreading behavior we observed for ECs in a light microscope fluorescence simulation experiment of the cell density effect. For a stably attached EC monolayer at 24 h post-addition, steady-state Deltaf and DeltaR values are higher and exhibit saturation behavior for both the hydrophilically treated gold surface as compared to the untreated surface. The steady-state 24 h Deltaf and DeltaR values of stably attached ECs are shifted from the 1 h attached ECs. The 24 h values are characteristic of a more energy-dissipative structure. This is consistent with the time-dependent elaboration of surface contacts in anchorage-dependent ECs via the attachment of intregrins to underlying extracellular matrix. It is also in agreement with the known energy dissipation function of the ECs that cover the interior of blood vessels and are exposed to continuous pulsatile blood flow.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号