首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this work we present a rapid and fully automated method to purify and desalt PCR products prior to analysis by electrospray ionization mass spectrometry. The protocol employs a commercial pipette tip packed with an anion-exchange resin and comprises four primary steps: tip pretreatment, sample loading, rinsing, and sample elution. This tip-based purification/desalting protocol has two distinct advantages over previously published methods. First, the protocol can be performed either manually (1-12 samples at a time), using a standard p10 manual pipette, or in a fully automated microtiter plate format (96 samples at a time) employing standard laboratory robotics. Additionally, the entire protocol from crude PCR product to an "electrosprayable" analyte solution requires only 10 microl of crude product and takes less than 20 min. Using capillary gel electrophoresis, we demonstrate an overall recovery efficiency of approximately 80% and demonstrate the exquisite desalting efficiency with high-performance electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. Using an internal mass standard we demonstrate sub-ppm mass measurement error which provides an unambiguous base composition for a 120-mer PCR product.  相似文献   

2.
We have set up high-throughput robotic systems to screen and optimise crystallisation conditions of biological macromolecules with the aim to make difficult structural biology projects easier. The initial screening involves two robots. A Tecan Genesis liquid handler is used to transfer commercially available crystallisation reagents from 15 ml test tubes into the reservoirs of 96-well crystallisation plates. This step is fully automated and includes a carousel for intermediate plate storage, a Beckman plate sealer and a robotic arm, which transfers plates in between steps. For adding the sample, we use a second robot, a 17-tip Cartesian Technologies PixSys 4200 SynQuad liquid handler, which uses a syringe/solenoid valve combination to dispense small quantities of liquid (typically 100 nl) without touching the surface of the plate. Sixteen of the tips are used to transfer the reservoir solution to the crystallisation wells, while the 17th tip is used to dispense the protein. The screening of our standard set of 1440 conditions takes about 3 h and requires 300 microl of protein solution. Once crystallisation conditions have been found, they are optimised using a second Tecan Genesis liquid handler, which is programmed to pipette gradients from four different corner solutions into a wide range of crystallisation plate formats. For 96-well plates, the Cartesian robot can be used to add the sample. The methods described are now used almost exclusively for obtaining diffraction quality crystals in our laboratory with a throughput of several thousand plates per year. Our set-up has been copied in many institutions worldwide.  相似文献   

3.
We designed an automated workstation for magnetic particle-based single nucleotide polymorphism (SNP) discrimination of ALDH genotypes. Bacterial magnetic particles (BMPs) extracted from Magnetospirillum magneticum AMB-1 were used as DNA carriers. The principle for SNP discrimination in this study was based on fluorescence resonance energy transfer (FRET) between FITC (donor) and POPO-3 (acceptor) bound to double-stranded DNA. The workstation is equipped with a 96-way automated pipetter which collects and dispenses fluids as it moves in x- and z-directions. The platform contains a disposable tip rack station, a reagent vessel serving as a stock for POPO-3 and FITC-labeled probes and a reaction station for a 96-well microtiter plate. BMPs were collected by attaching a neodymium iron boron sintered (Nd-Fe-B) magnet on the bottom of the microtiter plate. This system permits the simultaneous heating and magnetic separation of 96 samples per assay. The genotypes ALDH2*1 and ALDH2*2 were discriminated by calculating the relative fluorescence intensities on BMPs.  相似文献   

4.
Liquid nitrogen is colorless, odorless, extremely cold (-196 °C) liquid kept under pressure. It is commonly used as a cryogenic fluid for long term storage of biological materials such as blood, cells and tissues (1,2). The cryogenic nature of liquid nitrogen, while ideal for sample preservation, can cause rapid freezing of live tissues on contact - known as 'cryogenic burn' (2), which may lead to severe frostbite in persons closely involved in storage and retrieval of samples from Dewars. Additionally, as liquid nitrogen evaporates it reduces the oxygen concentration in the air and might cause asphyxia, especially in confined spaces (2). In laboratories, biological samples are often stored in cryovials or cryoboxes stacked in stainless steel racks within the Dewar tanks (1). These storage racks are provided with a long shaft to prevent boxes from slipping out from the racks and into the bottom of Dewars during routine handling. All too often, however, boxes or vials with precious samples slip out and sink to the bottom of liquid nitrogen filled tank. In such cases, samples could be tediously retrieved after transferring the liquid nitrogen into a spare container or discarding it. The boxes and vials can then be relatively safely recovered from emptied Dewar. However, the cryogenic nature of liquid nitrogen and its expansion rate makes sunken sample retrieval hazardous. It is commonly recommended by Safety Offices that sample retrieval be never carried out by a single person. Another alternative is to use commercially available cool grabbers or tongs to pull out the vials (3). However, limited visibility within the dark liquid filled Dewars poses a major limitation in their use. In this article, we describe the construction of a Cryotolerant DIY retrieval device, which makes sample retrieval from Dewar containing cryogenic fluids both safe and easy.  相似文献   

5.
A semi‐automated technique for massive parallel solid‐phase organic synthesis based on a “split only” strategy is described. Two different types of purpose‐oriented reaction vessels are used. The initial steps are performed in domino blocks, and the resin‐bound intermediates then split into wells of a micro plate for the last combinatorial step. The domino block is a reaction block for manual and semi‐automatic parallel solid‐phase organic synthesis that simplifies liquid exchange and integrates common synthetic steps. The synthesis in micro plates does not use any filter for separation of resin beads from the supernatant liquid, and allows high throughput parallel synthesis on solid phase to be performed. This technique, documented on examples of diverse disubstituted benzenes, includes the use of gaseous cleavage in the last synthetic step and allows the synthesis of thousands of compounds per day in mg quantities. © 1999 John Wiley & Sons, Inc. Biotechnol Bioeng (Comb Chem) 61:135–141, 1998/1999.  相似文献   

6.
This paper presents an automated method for extracting anabolic agents from urine samples for their GC–MS analysis by selected-ion monitoring. The sample preparation was carried out in a Hewlett-Packard 7686 SPE PrepStation system. Each 0.6-ml aliquot was hydrolyzed, extracted, dried and trimethylsilyl (TMS) derivatized in a 2-ml vial without any hands-on labor. When sample preparation was finished 2 μl of the extract was injected into the gas chromatograph by split (1:10) mode. Due to the small amount of free space in the 2-ml vials for handling the sample, parameters like time of hydrolysis, type of shaking, number of extractions and some TMS derivatization parameters had to be adjusted to achieve the best recovery for all of the compounds in the screening. Manual and automated sample preparation schemes were compared in terms of linearity, precision, accuracy, limit of detection and recovery data. When large concentrations were analyzed using the automated method no carry-over effect was observed.  相似文献   

7.
The demands on the biopharmaceutical sector to expedite process development have instigated the deployment of micro-biochemical engineering techniques to acquire manufacturing insight with extremely small sample volumes. In conjunction with automated liquid handlers, this permits the simultaneous evaluation of multiple operating conditions and reduces manual intervention. For these benefits to be sustained, novel ways are now required to accelerate analysis and so prevent this becoming a throughput bottleneck. For example, although Protein G HPLC is used to quantify antibody titres in bioprocess feedstocks, it can be time-consuming owing to the serial nature of its application. Although commercial options are available that can process many samples simultaneously, these require separate, potentially expensive instruments. A more integrated approach is desirable wherein the assay is implemented directly on a robot. This article describes a high-throughput alternative to antibody HPLC analysis which uses an eight-channel liquid handler to control pipette tips packed with 40 μL of Protein G affinity matrix. The linearity, range, limit of detection, specificity and precision of the method were established, with results showing that antibody was detected reliably and specifically between 0.10 and 1.00 mg/mL. Subsequently, the technique was used to quantify the antibody titre in ovine serum, which is used as feed material by BTG PLC for manufacturing FDA-approved polyclonal bio-therapeutics. The mean concentration determined by the tips was comparable to that found by HPLC, but the tip method delivered its results in less than 40% of the time and with the potential for further, substantial time-savings possible by using higher capacity robots.  相似文献   

8.
We describe a prototypical device for isolating biotinylated oligonucleotides for use in mass spectrometric analysis. It consists of monomeric avidin-coated microbeads trapped in a pipette tip and has been used for genotyping single nucleotide polymorphisms (SNPs) with the previously developed solid phase capture-single base extension (SPC-SBE) method. The device reduces processing time for genotyping by SPC-SBE and allows direct spotting of sample for rapid analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). In addition, it allows simultaneous processing of multiple samples and can be reused after regeneration of beads with no carryover effects. These results indicate that the microbead device is a low-cost tool that enhances sample cleanup prior to MS for SNP genotyping.  相似文献   

9.
Cramer R  Corless S 《Proteomics》2005,5(2):360-370
We have combined several key sample preparation steps for the use of a liquid matrix system to provide high analytical sensitivity in automated ultraviolet -- matrix-assisted laser desorption/ionisation -- mass spectrometry (UV-MALDI-MS). This new sample preparation protocol employs a matrix-mixture which is based on the glycerol matrix-mixture described by Sze et al. The low-femtomole sensitivity that is achievable with this new preparation protocol enables proteomic analysis of protein digests comparable to solid-state matrix systems. For automated data acquisition and analysis, the MALDI performance of this liquid matrix surpasses the conventional solid-state MALDI matrices. Besides the inherent general advantages of liquid samples for automated sample preparation and data acquisition the use of the presented liquid matrix significantly reduces the extent of unspecific ion signals in peptide mass fingerprints compared to typically used solid matrices, such as 2,5-dihydroxybenzoic acid (DHB) or alpha-cyano-hydroxycinnamic acid (CHCA). In particular, matrix and low-mass ion signals and ion signals resulting from cation adduct formation are dramatically reduced. Consequently, the confidence level of protein identification by peptide mass mapping of in-solution and in-gel digests is generally higher.  相似文献   

10.
The effect of sample vial type and sample composition on the ?erenkov count rate detected from 32P and 36Cl was studied using a liquid scintillation counter. When counting was done in the noncoincident mode, glass vials allowed higher counting efficiency than plastic vials. In the coincident mode light scattering caused by polyethylene and polyproplyene vials allowed higher counting efficiency than glass vials. Highest coincident counting efficiency was from plastic minivials in a glass carrier vial. Increased solute concentration in samples caused increased counting efficiency due to changes in the refractive index of the solution. This can cause significant counting efficiency changes with no sample channel ratio change in density gradient fractions. The use of wavelength shifters is shown to be inappropriate when the sample pH varies, as this can change the fluorescent properties of the shifters and thereby the observed count rate.  相似文献   

11.
Small glass shell vials (12 × 35 mm minivials), containing 2.0 ml of a dioxane-based scintillation solution plus a 14C-labeled sample, were placed in a conventional glass, 20-ml count vial and assayed in a scintillation spectrometer. Statistical comparison of counts recorded from 14C samples prepared both in the minivial system and conventional 20-ml count vials indicated that the two systems were equivalent with sample volumes of 10 and 100 μliters (1600-cpm solution) and 10 μliters (60-cpm solution). Conventional 20-ml glass or plastic count vials were both acceptable as containers for the minivials.There were no significant differences in the counts from samples in minivials placed on-center and off-center in the container vial. Cost per sample was reduced from 24.8 cents (conventional glass vials) to 4.7 cents (minivial system).  相似文献   

12.
Small glass shell vials (12 × 35 mm minivials), containing 2.0 ml of a dioxane-based scintillation solution plus a 14C-labeled sample, were placed in a conventional glass, 20-ml count vial and assayed in a scintillation spectrometer. Statistical comparison of counts recorded from 14C samples prepared both in the minivial system and conventional 20-ml count vials indicated that the two systems were equivalent with sample volumes of 10 and 100 μliters (1600-cpm solution) and 10 μliters (60-cpm solution). Conventional 20-ml glass or plastic count vials were both acceptable as containers for the minivials.There were no significant differences in the counts from samples in minivials placed on-center and off-center in the container vial. Cost per sample was reduced from 24.8 cents (conventional glass vials) to 4.7 cents (minivial system).  相似文献   

13.
AIM: Development of a fast, automated and reliable screening method for screening of large collections of bacterial strains with minimal handling time. METHODS AND RESULTS: The method is based on the injection of a small headspace sample (100 microl) from culture vials (2 ml) in 96-well format directly into the mass spectrometry (MS). A special sample tray has been developed for liquid media, and anaerobically grown cultures. In principle, all volatile components can be measured, but a representative mass fragment has to be obtained in the MS. Representative masses for 3-methylbutanal, 2-methylpropanal and benzaldehyde are 58, 72 and 105, respectively. In 1 day over 1500 samples could be analysed and the coefficient of variation for the response was <5%. CONCLUSION: Screening of 72 strains belonging to the genus Lactococcus in quadruple on the production of the key-flavour compound 3-methylbutanal illustrated the effectiveness of the method. Furthermore, knowledge of the biochemistry and physiology of 3-methylbutanal formation was used to optimize the composition of the growth medium to enhance 3-methylbutanal production, and thereby improve the screening. SIGNIFICANCE AND IMPACT OF THE STUDY: A commonly used method to control flavour formation in fermented food products is the selection of bacterial strains, which are able to produce the desired flavour compounds. As large collections of strains are available for such screenings, studying biodiversity of micro-organisms on the level of metabolic routes is strongly facilitated by highly automated high throughput screening methods for measuring enzyme activities or production of metabolites. Therefore, this method will be a useful tool for selecting flavour-producing strains and for enhancing starter culture development.  相似文献   

14.
A method for the routine quantitative determination of the major serotonin metabolite 5-hydroxyindole-3-acetic acid (5-HIAA) in urine is described. 5-HIAA was analyzed without prior sample cleanup, using an automated high-performance liquid chromatography system with isocratic elution and electrochemical detection (+0.60 V versus a Ag/AgCl reference electrode). The urine samples were mixed with a solution of the internal standard (5-hydroxyindole-3-propionic acid) and centrifuged. The supernatant was transferred to sealed glass vials, and a 2-microliters aliquot was injected directly onto a C18 reversed-phase analytical column, using an automatic sample injector. Samples of urine could be stored for several months at -80 or at +7 degrees C for 2 days without loss of 5-HIAA. However, a gradual decline with time occurred in crude samples stored at room temperature or above, as well as in urine samples diluted with the mobile phase. The detector response was linear in the range of 0-65 mumol/l 5-HIAA, and the intra- and interassay coefficients of variation were about 5 and 7%, respectively (n = 10).  相似文献   

15.
The semi-automatic bioanalytical assays for olpadronate [(3-dimethylamino-1-hydroxypropylidene)bisphosphonate] involves a protein precipitation with trichloroacetic acid and a double co-precipitation with calcium phosphate for serum samples and a triple calcium co-precipitation for urine samples. These manual procedures are followed by an automated solid-phase extraction on a cation-exchange phase. The procedure is continued either directly, at high olpadronate levels in urine, or after off-line evaporation under nitrogen and reconstitution in water on the same robotic workstation. The continued automatic procedure comprehends derivatization with (9-fluorenylmethyl)chloroformate, ion-pair liquid–liquid extraction and ion-pair HPLC with fluorescence detection at 274/307 nm. The intra- and inter-day precisions for urine and serum samples are typically in the 5–8% range for different olpadronate concentrations [levels near the lower limit of quantification (LLQ) excluded]. The LLQ is 5 ng/ml olpadronate for a 2.5-ml urine sample and 10 ng/ml for a 1-ml serum sample, respectively.  相似文献   

16.
Ferrofluid-modified trypsin has been used for the detection and determination of selected xenobiotics that inhibit trypsin activity. The procedure is useful especially when colored samples or samples containing suspended solid impurities are to be assayed. Ferrofluid-modified trypsin was inhibited by Ag+ and Pb2+, selected dyes (safranin, thionin), bacitracin and 4-aminobenzamidine. Enzymes immobilized on magnetic particles can form a basis of new automated assay procedures for the determination of xenobiotics.  相似文献   

17.
A high-throughput bioanalytical method based on automated sample transfer, automated solid phase extraction, and hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) analysis, has been developed for the determination of cetirizine, a selective H(1)-receptor antagonist. Deuterated cetirizine (cetirizine-d(8)) was synthesized as described and was used as the internal standard. Samples were transferred into 96-well plates using an automated sample handling system. Automated solid phase extraction was carried out using a 96-channel programmable liquid-handling workstation. Solid phase extraction 96-well plate on polymer sorbent (Strata X) was used to extract the analyte. The extracted samples were injected onto a Betasil silica column (50 x 3, 5 microm) using a mobile phase of acetonitrile-water-acetic acid-trifluroacetic acid (93:7:1:0.025, v/v/v/v) at a flow rate of 0.5 ml/min. The chromatographic run time is 2.0 min per injection, with retention time of cetirizine and cetirizine-d(8) both at 1.1 min. The system consisted of a Shimadzu HPLC system and a PE Sciex API 3000 or API 4000 tandem mass spectrometer with (+) ESI. The method has been validated over the concentration range of 1.00-1000 ng/ml cetirizine in human plasma, based on a 0.10-ml sample size. The inter-day precision and accuracy of the quality control (QC) samples demonstrated <3.0% relative standard deviation (R.S.D.) and <6.0% relative error (RE). Stability of cetirizine in stock solution, in plasma, and in reconstitution solution was established. The absolute extraction recovery was 85.8%, 84.5%, and 88.0% at 3, 40, and 800 ng/ml, respectively. The recovery for the internal standard was 84.1%. No adverse matrix effects were noticed for this assay. The automation of the sample preparation steps not only increased the analysis throughput, but also increased method ruggedness. The use of a stable isotope-labeled internal standard further improved the method ruggedness. Practical issues of analyzing incurred samples were discussed. This HILIC-MS/MS method for analysis of citirizine in human plasma was successfully used to support clinical studies.  相似文献   

18.
19.
Automation of a chloramphenicol acetyltransferase assay   总被引:1,自引:0,他引:1  
Accurate quantification of chloramphenicol acetyltransferase (CAT) enzyme activity in a large number of samples has been achieved through robotization of a CAT assay on a laboratory workstation (Biomek 1000). The basic principle of this CAT assay relies on the selective diffusion of [3H]acetylchloramphenicol into a water-immiscible liquid scintillation cocktail. This methodology gives unique characteristics to this robotized protocol by allowing complete control over the kinetics of the CAT enzymatic reaction which is a critical parameter in the CAT assay. Thus it has been possible to optimize the CAT assay for every processed sample, through real time monitoring of the enzymatic reaction, and to achieve maximum accuracy in CAT quantification. Moreover the sensitivity of this automated assay is high (detection threshold; 10(-4) CAT unit), and the sample processing is fast (approximately 125 samples per hour). Compared to other CAT assay protocols currently used, our robotized technique offers major advantages in terms of CAT quantification, and sets new standards for CAT assay productivity.  相似文献   

20.
DigesTip is a new device for in-solution protein digestion, based on a patent pending technology, able to immobilize enzymes (trypsin, in this case) on a solid surface, keeping their activity preserved. DigesTip is a standard pipette tip, usable both by human and by robots. Its main performances are: very short digestion time (1 min) and usability with low protein sample concentrations (5 microg/mL). DigesTip obtains a clear signal in MS measurements and its usage rules out several preparative steps.  相似文献   