首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Electrical frequency dependent characterization of DNA hybridization   总被引:2,自引:0,他引:2  
The hybridization of oligomeric DNA was investigated using the frequency dependent techniques of electrochemical impedance spectroscopy (EIS) and quartz crystal microgravimetry (QCM). Synthetic 5'-amino terminated single stranded oligonucleotides (ssDNA) were attached to the exposed glass surface between the digits of microlithographically fabricated interdigitated microsensor electrodes using 3-glycidoxypropyl-trimethoxysilane. Similar ssDNA immobilization was achieved to the surface of the gold driving electrodes of AT-cut quartz QCM crystals using 3-mercaptopropyl-trimethoxysilane. Significant changes in electrochemical impedance values (both real and imaginary components) (11% increase in impedance modulus at 120 Hz) and resonant frequency values (0.004% decrease) were detected as a consequence of hybridization of the bound ssDNA upon exposure to its complement under hybridization conditions. Non-complementary (random) sequence sowed a modest decrease in impedance and a non-detectable change in resonant frequency. The possibility to detect the binding state of DNA in the vicinity of an electrode, without a direct connection between the measurement electrode and the DNA, has been demonstrated. The potential for development of label-free, low density DNA microarrays is demonstrated and is being pursued.  相似文献   

2.
DNA functionalised semiconductor metallic oxide electrodes have been developed for the direct electrochemical detection of DNA hybridization, without labelling or the introduction of a redox couple. Conductive CdIn(2)O(4) thin films with controlled properties were deposited on glass substrates using an aerosol pyrolysis technique. The films exhibit a polycrystalline microstructure with a surface roughness of 1.5 nm (r.m.s.) and an electrical resistivity ranging between 1 and 3 x 10(-3) Omega cm. These electrodes were functionalised using hydroxylation and silanisation steps, to allow the binding of DNA probe sequences (20 bases). The electrical detection of DNA hybridization with complementary sequences has been performed using electrochemical impedance spectrometry (EIS) measuring the variation of impedance before and after hybridization. Two set-ups were used, a standard set-up including three electrodes and a set-up including two symmetrical electrodes. In both configurations, a significant increase of the impedance modulus, more particularly of the real part of the impedance (160-225% according to the electrochemical cell used) has been obtained over a frequency range of 10-10(5)Hz. DNA hybridization has also been systematically confirmed using the fluorescence spectrometry. This study emphasizes the high sensitivity of the CdIn(2)O(4) as a working electrode for the detection of biological events occurring at the electrode surface.  相似文献   

3.
A simple and sensitive electrochemical DNA biosensor based on in situ DNA amplification with nanosilver as label and horseradish peroxide (HRP) as enhancer has been designed. The thiolated oligomer single-stranded DNA (ssDNA) was initially directly immobilized on a gold electrode, and quartz crystal microbalance (QCM) gave the specific amount of ssDNA adsorption of 6.3 ± 0.1 ng/cm2. With a competitive format, hybridization reaction was carried out via immersing the DNA biosensor into a stirred hybridization solution containing different concentrations of the complementary ssDNA and constant concentration of nanosilver-labeled ssDNA, and then further binding with HRP. The adsorbed HRP amount on the probe surface decreased with the increment of the target ssDNA in the sample. The hybridization events were monitored by using differential pulse voltammetry (DPV) with the adsorbed HRP toward the reduction of H2O2. The reduction current from the enzyme-generated product was related to the number of target ssDNA molecules in the sample. A detection of 15 pmol/L for target ssDNA was obtained with the electrochemical DNA biosensor. Additionally, the developed approach can effectively discriminate complementary from non-complementary DNA sequence, suggesting that the similar enzyme-labeled DNA assay method hold great promises for sensitive electrochemical biosensor applications.  相似文献   

4.
The processes of adhesion, spreading and proliferation of human mammary cancer cells MCF-7 on two Au electrodes with different surface roughness (R(f) and R(f)=3.2 or 1.1) were monitored and clearly identified with the quartz crystal microbalance (QCM) technique. Analyses of the QCM responses on the resonant frequency shifts (Deltaf(0)) vs. the motional resistance changes (DeltaR(1)) revealed a significant surface-stress effect in the involved courses, in addition to a viscodensity effect and a relatively small mass effect (especially at the smooth electrode). Experiments of fluorescence microscopy, cyclic voltammetry and electrochemical impedance spectroscopy were conducted to investigate the cell population on the electrode vs. the electrode-surface roughness. Simplified equations are deduced to quantitatively evaluate the surface stress, and a novel QCM method for dynamically measuring the surface stress on an electrode in cell-culture course is thus described. It was found that the smoother surface (R(f)=1.1) gave a higher surface stress during cell attachment and less cell population on it than the rougher surface (R(f)=3.2). In addition, real-time QCM monitoring showed on the same electrode the surface stress induced by hepatic normal cells being notably higher than that caused by hepatic cancer cells at cell-attachment stage, suggesting that the surface-stress measurement can exhibit the difference of adhesion-performance between the healthy and ill-behaved cells.  相似文献   

5.
A direct electrochemical DNA biosensor based on zero current potentiometry was fabricated by immobilization of ssDNA onto gold nanoparticles (AuNPs) coated pencil graphite electrode (PGE). One ssDNA/AuNPs/PGE was connected in series between clips of working and counter electrodes of a potentiostat, and then immersed into the solution together with a reference electrode, establishing a novel DNA biosensor for specific DNA detection. The variation of zero current potential difference (ΔE(zcp)) before and after hybridization of the self-assembled probe DNA with the target DNA was used as a signal to characterize and quantify the target DNA sequence. The whole DNA biosensor fabrication process was characterized by cyclic voltammetry and electrochemical impedance spectroscopy with the use of ferricyanide as an electrochemical redox indicator. Under the optimized conditions, ΔE(zcp) was linear with the concentrations of the complementary target DNA in the range from 10nM to 1μM, with a detection limit of 6.9nM. The DNA biosensor showed a good reproducibility and selectivity. Prepared DNA biosensor is facile and sensitive, and it eliminates the need of using exogenous reagents to monitor the oligonucleotides hybridization.  相似文献   

6.
Ultrasensitive DNA hybridization biosensor based on polyaniline   总被引:1,自引:0,他引:1  
Ultrasensitive DNA hybridization biosensor based on polyaniline (PANI) electrochemically deposited onto Pt disc electrode has been fabricated using biotin-avidin as indirect coupling agent to immobilize single-stranded 5'-biotin end-labeled polydeoxycytidine (BdC) probes and 5'-biotin end-labeled 35 base-long oligonucleotide probe (BdE) to detect complementary target, using both direct electrochemical oxidation of guanine and redox electroactive indicator methylene blue (MB), respectively. These polyaniline-based disc electrodes have been characterized using differential pulse voltammetry (DPV), Fourier transform infrared spectroscopy (FT-IR), impedance measurements and scanning electron microscopy (SEM) techniques, respectively. Compared to direct electrochemical oxidation of guanine, hybridization detection using MB results in the enhanced detection limit by about 100 times. These DNA immobilized PANI electrodes have hybridization response time of about 60 s.  相似文献   

7.
A new procedure for fabricating deoxyribonucleic acid (DNA) electrochemical biosensor was developed based on covalent immobilization of target single-stranded DNA (ssDNA) on Au electrode that had been functionalized by direct coupling of sol-gel and self-assembled technologies. Two siloxanes, 3-mercaptopropyltrimethoxysiloxane (MPTMS) and 3-glycidoxypropyltrimethoxysiloxane (GPTMS) were used as precursors to prepare functionally self-assembly sol-gel film on Au electrode. The thiol group of MPTMS allowed assembly of MPTMS sol-gel on gold electrode surface. Through co-condensation between silanols, GPTMS sol-gel with epoxide groups interconnected into MPTMS sol-gel and enabled covalent immobilization of target NH(2)-ssDNA through epoxide/amine coupling reaction. The concentration of MPTMS and GPTMS influenced the performance of the resulting biosensor due to competitive sol-gel process. The linear range of the developed biosensor for determination of complementary ssDNA was from 2.51 x 10(-9) to 5.02 x 10(-7)M with a detection limit of 8.57 x 10(-10)M. The fabricated biosensor possessed good selectivity and could be regenerated. The covalent immobilization of target ssDNA on self-assembled sol-gel matrix could serve as a versatile platform for DNA immobilization and fabrication of biosensors.  相似文献   

8.
A conducting polymer sensor for direct label-free DNA detection based on a polythiophene bearing an electroactive linker group is investigated. DNA hybridization is studied by electrochemical impedance spectroscopy (EIS) and quartz crystal microbalance (QCM) techniques. Modelling of DNA hybridization by EIS measurements exhibits the contribution of nucleic acid to a superficial p-doping process. A 675-mer single-stranded DNA is produced using asymmetric PCR from a DNA sequence of a transposable element mariner and hybridized to the previously immobilized probe. Electrochemical stimulus leads to the release "on demand" of DNA fragments and the amount delivery permits to do PCR amplification.  相似文献   

9.
Min K  Cho M  Han SY  Shim YB  Ku J  Ban C 《Biosensors & bioelectronics》2008,23(12):1819-1824
Tuberculosis is the most frequent cause of infection-related death worldwide. We constructed a simple and direct electrochemical sensor to detect interferon (IFN)-gamma, a selective marker for tuberculosis pleurisy, using its RNA and DNA aptamers. IFN-gamma was detected by its 5'-thiol-modified aptamer probe immobilized on the gold electrode. Interaction between IFN-gamma and the aptamer was recorded using electrochemical impedance spectroscopy and quartz crystal microbalance (QCM) with high sensitivity. The RNA-aptamer-based sensor showed a low detection limit of 100 fM, and the DNA-aptamer-based sensor detected IFN-gamma to 1 pM in sodium phosphate buffer. With QCM analysis, the aptamer immobilized on the electrode and IFN-gamma bound to the aptamer probe was quantified. This QCM result shows that IFN-gamma exists in multimeric forms to interact with the aptamers, and the RNA aptamer prefers the high multimeric state of IFN-gamma. Such a preference may describe the low detection limit of the RNA aptamer shown by impedance analysis. In addition, IFN-gamma was detected to 10 pM by the DNA aptamer in fetal bovine serum, a mimicked biological system, which has similar components to pleural fluid.  相似文献   

10.
The use of a commercial, silver-coated quartz crystal microbalance (QCM) as a disposable, low-cost, and reliable DNA sensor is presented. This is an incorporation of polymer-based silver electrode shielding and photochemistry-based surface modification for covalent DNA immobilization. To prevent undesired oxidation, the silver electrodes are coated with thin polystyrene films. The polymer surfaces are then modified by a photoreactive biotin derivative (photobiotin) under UV irradiation. The resulting biotin residues on the polymer-shielded surface react with a tetrameric avidin. Consequently a biotin-labeled DNA probe can be immobilized through a biotin-avidin-biotin bridge. A 14-mer single-stranded biotin-DNA probe and a 70-mer single-stranded DNA fragment containing complementary or noncomplementary sequences are used as a model system for DNA hybridization assay on the proposed sensors. The shielding ability of the polystyrene coatings after photo irradiation is investigated. The DNA probe binding capacity, hybridization efficiency, and kinetics are also investigated.  相似文献   

11.
The quartz crystal microbalance (QCM), in combination with electrochemical impedance spectroscopy (EIS), has been utilized to monitor in situ antihuman IgG (hIgG) adsorption on bare poly(o-phenylenediamine) (PPD)- and 1-dodecanethiol (C12SH)-modified Au electrodes and succeeding human IgG reaction, respectively. The resonant frequency (f) and the motional resistance (R(1)) of the piezoelectric quartz crystal (PQC) as well as electrochemical impedance (EI) parameters were measured and discussed. The standard heterogeneous rate constants of the ferricyanide/ferrocyanide couple before and after the antibody adsorption and antibody-antigen reactions were determined. The results show that the amount for antibody adsorption was the greatest on the most hydrophobic (1-dodecanethiol-modified) surface, while the antibody bioactivity was almost identical on the three kinds of surfaces. Two parameters simultaneously obtained, Deltaf and DeltaC(s) (interfacial capacitance), have been used for the first time to estimate both the association constant of the immunoreaction and the valence of antigen with satisfactory results. The proposed method may find wide application in interfacial biochemistry studies for its advantages in providing real-time multidimensional piezoelectric and electrochemical impedance information.  相似文献   

12.
With the goal of developing a quartz crystal microbalance (QCM)-based DNA sensor, we have conducted an in situ QCM study along with fluorescence measurements using oligonucleotides (15-mer) as a model single-stranded DNA (ss-DNA) in two different aqueous buffer solutions; the sequence of 15-mer is a part of iduronate-2-sulphate exon whose mutation is known to cause Hunter syndrome, and the 15-mer is thiolated to be immobilized on the Au-coated quartz substrate. The fluorescence data indicate that the initial immobilization as well as the subsequent hybridization with a complementary strand is hardly dependent on the kind of buffer solution. In contrast, the mass increases deducible from the decrease of QCM frequency via the Sauerbrey equation are 2.7-6.2 and 3.0-4.4 times larger than the actual mass increases, as reflected in the fluorescence measurements, for the immobilization and the subsequent hybridization processes, respectively. Such an overestimation is attributed to the trapping of solvent as well as the formation of quite a rigid hydration layer associated with the higher viscosities and/or densities of the buffer solutions. Another noteworthy observation is the excessively large frequency change that occurs when the gold electrode is deposited in advance with Au nanoparticles. This clearly illustrates that the QCM detection of DNA hybridization is also affected greatly by the surface morphology of the electrode. These enlarged signals are altogether presumed to be advantageous when using a QCM system as an in situ probing device in DNA sensors.  相似文献   

13.
Single square voltage pulses applied to buried electrodes result in dramatic rate increases for (1) selective covalent bonding (immobilization) of single-stranded DNA (ssDNA) probes to a functionalized thin film SiO2 surface on a plastic substrate and (2) hybridization of ssDNA to the immobilized probe. DNA immobilization and hybridization times are 100 ns and 10 μs, respectively, about 109 times faster than the corresponding passive reactions without electric field. Surface coverage is comparable. Duration, magnitude and slew rate of the voltage pulse are all key factors controlling the rates of ssDNA immobilization and hybridization. With rise times of 4.5 ns, pulses shorter than 1 ms and voltages below 1 V are effective. The ssDNA adsorbed on the surface is reoriented by the rapidly changing electric field. This reduces steric barriers and speeds the immobilization and hybridization reactions. These results open the way for pixel-addressed microarrays driven by silicon microelectronics circuits.  相似文献   

14.
Liu X  Qu X  Dong J  Ai S  Han R 《Biosensors & bioelectronics》2011,26(8):3679-3682
A novel electrochemical method of detecting DNA hybridization is presented based on the change in flexibility between the single and double stranded DNA. A recognition surface based on gold nanoparticles (GNPs) is firstly modified via mixing self-assembled monolayer of thiolated probe DNA and 1,6-hexanedithiol. The hybridization and electrochemical detection are performed on the surface of probe-modified GNPs and electrode, respectively. Here in our method the charge transfer resistance (R(ct)) signal is enhanced by blocking the surface of electrode with DNA covered GNPs. The GNPs will be able to adsorb on the gold electrode when covered with flexible single stranded DNA (ssDNA). On the contrary, it will be repelled from the electrode, when covered with stiff double stranded DNA (dsDNA). Therefore, different R(ct) signals are observed before and after hybridization. The hybridization events are monitored by electrochemical impedance spectroscopy (EIS) measurement based on the R(ct) signals without any external labels. This method provides an alternative route for expanding the range of detection methods available for DNA hybridization.  相似文献   

15.
A method for rapid sensitive detection of DNA or RNA was designed using a composite screen-printed carbon electrode modified with multi-walled carbon nanotubes (MWNTs). MWNTs showed catalytic characteristics for the direct electrochemical oxidation of guanine or adenine residues of signal strand DNA (ssDNA) and adenine residues of RNA, leading to indicator-free detection of ssDNA and RNA concentrations. With an accumulation time of 5 min, the proposed method could be used for detection of calf thymus ssDNA ranging from 17.0 to 345 microg ml(-1) with a detection limit of 2.0 microg ml(-1) at 3 sigma and yeast tRNA ranging from 8.2 microg ml(-1) to 4.1 mg ml(-1). AC impedance was employed to characterize the surface of modified electrodes. The advantages of convenient fabrication, low-cost detection, short analysis time and combination with nanotechnology for increasing the sensitivity made the subject worthy of special emphasis in the research programs and sources of new commercial products.  相似文献   

16.
A quartz crystal microbalance (QCM) DNA sensor, based on the nanoparticle amplification method, was developed for detection of Escherichia coli O157:H7. A thiolated single-stranded DNA (ssDNA) probe specific to E. coli O157:H7 eaeA gene was immobilized onto the QCM sensor surface through self-assembly. The hybridization was induced by exposing the ssDNA probe to the complementary target DNA, and resulted in the mass change and therefore frequency change of the QCM. Streptavidin conjugated Fe(3)O(4) nanoparticles (average diameter=145 nm) were used as "mass enhancers" to amplify the frequency change. Synthesized biotinylated oligonucleotides as well as E. coli O157:H7 eaeA gene fragments (151 bases) amplified using asymmetric PCR with biotin labeled primers were tested. As low as 10(-12)M synthesized oligonucleotides and 2.67 x 10(2) colony forming unit (CFU)/ml E. coli O157:H7 cells can be detected by the sensor. Linear correlation between frequency change and logarithmic number of bacterial cell concentration was found for E. coli O157:H7 from 2.67 x 10(2) to 2.67 x 10(6)CFU/ml.  相似文献   

17.
We report on the study of immobilization DNA probes onto quartz crystal oscillators by self-assembly technique to form variety types of mono- and multi-layered sensing films towards the realization of DNA diagnostic devices. A 18-mer DNA probe complementary to the site of genetic beta-thalassaemia mutations was immobilized on the electrodes of QCM by covalent bonding or electrostatic adsorption on polyelectrolyte films to form mono- or multi-layered sensing films by self-assembled process. Hybridization was induced by exposure of the QCMs immobilized with DNA probe to a test solution containing the target nucleic acid sequences. The kinetics of DNA probe immobilization and hybridization with the fabricated DNA sensors were studied via in-situ frequency changes. The characteristics of QCM sensors containing mono- or multi-layered DNA probe constructed by direct chemical bonding, avidin-biotin interaction or electrostatic adsorption on polyelectrolyte films were compared. Results indicated that the DNA sensing films fabricated by immobilization of biotinylated DNA probe to avidin provide fast sensor response and high hybridization efficiencies. The effects of ionic strength of the buffer solution and the concentration of target nucleic acid used in hybridization were also studied. The fabricated DNA biosensor was used to detect a set of real samples. We conclude that the microgravimetric DNA sensor with its direct detection of amplified products provide a rapid, low cost and convenient diagnostic method for genetic disease.  相似文献   

18.
We have developed a simple and renewable electrochemical biosensor based on carbon paste electrode (CPE) for the detection of DNA synthesis and hybridization. CPE was modified with gold nanoparticles (AuNPs), which are helpful for immobilization of thiolated bioreceptors. AuNPs were characterized by scanning electron microscopy (SEM). Self-assembled monolayers (SAMs) of thiolated single-stranded DNA (SH–ssDNA) of the amelogenin gene was formed on CPE. The immobilization of the probe and its hybridization with the target DNA was optimized using different experimental conditions. The modified electrode was characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The electrochemical response of ssDNA hybridization and DNA synthesis was measured using differential pulse voltammetry (DPV) with methylene blue (MB) as an electroactive indicator. The new biosensor can distinguish between complementary and non-complementary strands of amelogenin ssDNA. Genomic DNA was extracted from blood and was detected based on changes in the MB reduction signal. These results demonstrated that the new biosensor could be used for sex determination. The proposed biosensor in this study could be used for detection and discrimination of polymerase chain reaction (PCR) products of amelogenin DNA.  相似文献   

19.
We investigate the feasibility of coupling the quartz crystal microbalance (QCM) with magnetic separation for on-line analysis. A flow cell was integrated with QCM and magnetic force for the analysis of magnetic and nonmagnetic samples. The resonant frequency change (Deltaf) of QCM was related to the amount of deposited magnetic nanoparticles. This experiment demonstrates that QCM can be used as an on-line detector for magnetic separation. The QCM also gives a characteristic response of the binding between the streptavidin and biotin labeled on the magnetic nanoparticles. Biotin-labeled magnetic nanoparticles were flowed through a gold electrode of QCM to deposit as a matrix for selective capturing streptavidin. The resonant frequency change of QCM was proportional to the amounts of streptavidin captured by biotin. This technique can provide a simple, economic, and automatic method for on-line detection of biomarkers.  相似文献   

20.
Ding X  Li J  Hu J  Li Q 《Analytical biochemistry》2005,339(1):46-53
The direct electron transfer of surface-confined horse heart cytochrome c (Cyt c) was achieved using COOH-terminated alkanethiolate-modified gold electrode. Later DNA was immobilized on the two-layer modified electrode. The quantitative determination of DNA was explored and the interaction between cytochrome c and DNA was studied. The binding site sizes were determined to be 15 bp per Cyt c molecule with double-stranded (ds) DNA and 30 nucleotides binding one Cyt c molecule with single-stranded (ss) DNA. At the dsDNA/Cyt c/MUA/Au electrode, the rate constant of oxidation electron transfer k(s,ox)=1.59x10(-3)cms-1 was obtained, at the ssDNA/Cyt c/MUA/Au electrode, the value was 2.43x10(-3)ms-1 when the scan rate was 1.0V/s. The different electrodes were characterized with electrochemical quartz crystal microbalance and atomic force microscope.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号