首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We describe the ScanMIC method, a colorimetric MIC method for susceptibility testing of gram-negative fermentative bacteria. The method is a slight modification of the National Committee for Clinical Laboratory Standards (NCCLS) recommended broth microdilution method that uses a redox indicator 2,3,5-triphenyltetrazolium chloride (TTC) to enhance the estimate of bacterial growth inhibition in a microplate and a flatbed scanner to capture the microplate image. In-house software was developed to transform the microplate image into numerical values based on the amount of bacterial growth and to generate the MICs automatically. The choice of indicator was based on its low toxicity and ease of reading by scanner. We compared the ScanMIC method to the NCCLS recommended broth microdilution method with 197 coliform strains against seven antibacterial agents. The interpretative categorical agreement was obtained in 92.4% of the assays, and the agreement for MIC differences (within +/-1 log(2) dilution) was obtained in 96% for ScanMIC versus broth microdilution and 97% for a two-step incubation colorimetric broth microdilution versus the broth microdilution method. The method was found to be labor-saving, not to require any initial investment, and to show reliable results. Thus, the ScanMIC method could be useful for epidemiological surveys that include susceptibility testing of bacteria.  相似文献   

2.
Static light scattering (SLS) is a commonly used technique for monitoring dynamics of high molecular weight protein complexes such as protein oligomers or aggregates. However, traditional methods are limited to testing a single condition and typically require large amounts of protein and specialized equipment. We show that a standard microplate reader can be used to characterize the molecular dynamics of different types of protein complexes, with the multiple advantages of microscale experimental volumes, semi-automated protocols and highly parallel processing.  相似文献   

3.
We describe the ScanMIC method, a colorimetric MIC method for susceptibility testing of gram-negative fermentative bacteria. The method is a slight modification of the National Committee for Clinical Laboratory Standards (NCCLS) recommended broth microdilution method that uses a redox indicator 2,3,5-triphenyltetrazolium chloride (TTC) to enhance the estimate of bacterial growth inhibition in a microplate and a flatbed scanner to capture the microplate image. In-house software was developed to transform the microplate image into numerical values based on the amount of bacterial growth and to generate the MICs automatically. The choice of indicator was based on its low toxicity and ease of reading by scanner. We compared the ScanMIC method to the NCCLS recommended broth microdilution method with 197 coliform strains against seven antibacterial agents. The interpretative categorical agreement was obtained in 92.4% of the assays, and the agreement for MIC differences (within ±1 log2 dilution) was obtained in 96% for ScanMIC versus broth microdilution and 97% for a two-step incubation colorimetric broth microdilution versus the broth microdilution method. The method was found to be labor-saving, not to require any initial investment, and to show reliable results. Thus, the ScanMIC method could be useful for epidemiological surveys that include susceptibility testing of bacteria.  相似文献   

4.
Measurement of proteasome activity is fast becoming a commonly used assay in many laboratories. The most common method to measure proteasome activity involves measuring the release of fluorescent tags from peptide substrates in black microplates. Comparisons of black plates used for measuring fluorescence with different properties show that the microplate properties significantly affect the measured activities of the proteasome. The microplate that gave the highest reading of trypsin-like activity of the purified 20S proteasome gave the lowest reading of chymotrypsin-like activity of the 20S proteasome. Plates with medium binding surfaces from two different companies showed an approximately 2-fold difference in caspase-like activity for purified 20S proteasomes. Even standard curves generated using free 7-amino-4-methylcoumarin (AMC) were affected by the microplate used. As such, significantly different proteasome activities, as measured in nmol AMC released/mg/min, were obtained for purified 20S proteasomes as well as crude heart and liver samples when using different microplates. The naturally occurring molecule betulinic acid activated the chymotrypsin-like proteasome activity in three different plates but did not affect the proteasome activity in the nonbinding surface microplate. These findings suggest that the type of proteasome activity being measured and sample type are important when selecting a microplate.  相似文献   

5.
The growth indicators 2,3,5-triphenyltetrazolium chloride (TTC), 2-[4-iodophenyl]-3-[4-dinitrophenyl]-5-phenyltetrazolium chloride (INT), 2,3-bis[2-methoxy-4-nitro-5-sulfophenyl]-2H-tetrazolium-5-carboxanilide inner salt (XTT), 3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide (MTT), and resazurin were tested for their ability to indicate bacterial growth/growth inhibition. Two reading devices were evaluated and compared, a microplate spectrophotometer and a digital flatbed scanner. The bacteria used in the study were cultivated in 96-wells microplates and readings were made after 24 h. The scanned pictures were analysed with a software developed in-house to generate numerical values. It was found that resazurin was difficult to use since it shifts between three colours. MTT and TTC had a high correlation between the spectrophotometer data and the data from the scanned images. The reproducibility was similar for both reading devices. In no case was there a need to resuspend the pellets before reading. Both the XTT and INT showed lower correlations.It is concluded that bacterial growth/growth inhibition can be easily and reproducibly measured from microplate cultivations with a flatbed scanner or with a microplate spectrophotometer.  相似文献   

6.
The use of poly(N-vinyl-2-pyrrolidone) (PVP) hydrogel-supported luminol chemiluminescence (CL) for the automatic determination of hydrogen peroxide and the quantification of the antiradical capacity of Trolox is described. The hydrogel containing luminol and hemin is prepared directly on a 96-well microplate and can be stored for up to 3 months without significant decrease in CL quantum yields. Furthermore, this system can also be used as a secondary light standard for the calibration of microplate luminometers.  相似文献   

7.
Cell-based beta-lactamase reporter gene assays designed to measure the functional responses of G-protein-coupled receptors (GPCRs) were miniaturized to less than 2 microL total assay volume in a 3456-well microplate. Studies were done to evaluate both receptor agonists and antagonists. The pharmacology of agonists and antagonists for target GPCRs originally developed in a 96-well format was recapitulated in a 3456-well microplate format without compromising data quality or EC(50)/IC(50) precision. These assays were employed in high-throughput screening campaigns, allowing the testing of more than 150,000 compounds in 8 h. The instrumentation used and practical aspects of the assay development are discussed.  相似文献   

8.
Reversible precipitation can be used as an efficient purification tool for proteins. In addition, identifying conditions under which precipitation or aggregation occurs is of key importance in the bioprocessing and pharmaceutical industry, as this can aid in better formulations and hinder aggregation in chromatography. We have evaluated the precipitation of proteins as determined by light scattering in microplates as a tool for the high‐throughput determination of thermodynamic parameters for protein precipitation, with the potential for screening of formulation additives and relevant bioprocess conditions such as pH. This provides a useful complementary technique to existing microplate‐based protein thermostability measurements. Using hen egg‐white lysozyme and alcohol dehydrogenase as model proteins we have determined the extent of reversible precipitation as a function of ammonium sulfate and sodium chloride concentrations, and also demonstrated global fitting of the data to generate a model where the fraction precipitated can be predicted for any given condition. The global fit provided thermodynamic parameters, including the free energy for protein precipitation, and also allowed an approximate determination of the average size of the structural nucleus that contributes to the free energy of precipitation for each protein. The rapid collection of thermodynamic parameters for protein precipitation, in parallel with protein thermostability measurements, will provide a powerful platform for protein formulation, and also lead to datasets useful for testing theoretical predictions of reversible precipitation based on the molecular modeling of specific protein structure interactions. Biotechnol. Bioeng. 2011;108: 322–332. © 2010 Wiley Periodicals, Inc.  相似文献   

9.
Direct monitoring of recognition processes at the molecular level is a valuable tool for studying reaction kinetics to assess affinity constants (e.g. drugs to receptors) and for designing rapid single step immunoassays. Methods currently used to gain information about binding processes predominantly depend on surface plasmon resonance. These systems use excitation with coherent light in attenuated total reflection geometry to obtain discrimination between surface-bound and free molecules in solution. Therefore labeling of the compounds is not necessary, but due to the complexity of the measuring setup the method is rather costly. In this contribution we present a simple method for performing kinetic single step biorecognition assays with fluorophore labeled compounds using the fluorescence enhancement properties of surface bound silver colloids. Silver colloids are bound to standard microplates via silanization of the plastic surface. Fluorophores close to this colloid coated surface show a significant gain in fluorescence compared to fluorophores farther away in the bulk solution. Therefore discrimination between surface bound and free fluorophores is possible and the binding of, for example, fluorophore labeled antibodies to antigens immobilized on the colloid surface results in increasing fluorescence intensity. Utilization of standard microplates makes this method fully compatible with conventional microplate processing and reading devices. Neither excitation with coherent laser light nor ATR geometry is required, the measurement is performed in a standard fluorescence microplate reader in front face geometry with a xenon flash lamp as excitation source. Methods for the preparation of colloid-coated microplates and fluorescence-enhanced biorecognition assays are presented. Additionally the dependence of the system performance on the structure and properties of the metal colloid coated surface is described. A two-component biorecognition model system shows a detection limit in the subnanomolar range. The ease of colloid-surface preparation and the high sensitivity makes fluorescence enhancement at colloid-coated microplates a valuable tool for studying reaction kinetics and performing rapid single-step immunoassays.  相似文献   

10.
Recombinant Rhodopseudomonas palustris, harboring the carotenoid-metabolizing gene crtI (CrtIBS), and whose color changes from greenish yellow to red in response to inorganic As(III), was cultured in transparent microplate wells illuminated with a light emitting diode (LED) array. The cells were seen to grow better under near-infrared light, when compared with cells illuminated with blue or green LEDs. The absorbance ratio of 525 to 425 nm after cultivation for 24 h, which reflects red carotenoid accumulation, increased with an increase in As(III) concentrations. The detection limit of cultures illuminated with near-infrared LED was 5 microgram/l, which was equivalent to that of cultures in test tubes illuminated with an incandescent lamp. A near-infrared LED array, in combination with a microplate, enabled the simultaneous handling of multiple cultures, including CrtIBS and a control strain, for normalization by the illumination of those with equal photon flux densities. Thus, the introduction of a near-infrared LED array to the assay is advantageous for the monitoring of arsenic in natural water samples that may contain a number of unknown factors and, therefore, need normalization of the reporter event.  相似文献   

11.
In response to the growing need for functional analysis of the human genome, we have developed a platform for high-throughput functional screening of genes overexpressed from lentiviral vectors. Protein-coding human open reading frames (ORFs) from the Mammalian Gene Collection were transferred into lentiviral expression vector using the highly efficient Gateway recombination cloning. Target ORFs were inserted into the vector downstream of a constitutive promoter and upstream of an IRES controlled GFP reporter, so that their transfection, transduction and expression could be monitored by fluorescence. The expression plasmids and viral packaging plasmids were combined and transfected into 293T cells to produce virus, which was then used to transduce the screening cell line. We have optimised the transfection and transduction procedures so that they can be performed using robotic liquid handling systems in arrayed 96-well microplate, one-gene-per-well format, without the need to concentrate the viral supernatant. Since lentiviruses can infect both dividing and non-dividing cells, this system can be used to overexpress human ORFs in a broad spectrum of experimental contexts. We tested the platform in a 1990 gene pilot screen for genes that can increase proliferation of the non-tumorigenic mammary epithelial cell line MCF-10A after removal of growth factors. Transduced cells were labelled with the nucleoside analogue 5-ethynyl-2'-deoxyuridine (EdU) to detect cells progressing through S phase. Hits were identified using high-content imaging and statistical analysis and confirmed with vectors using two different promoters (CMV and EF1α). The screen demonstrates the reliability, versatility and utility of our screening platform, and identifies novel cell cycle/proliferative activities for a number of genes.  相似文献   

12.
The computer screen photo-assisted technique (CSPT), a method for substance classification based on spectral fingerprinting, which involves just a computer screen and a web camera as measuring platform is used here for the evaluation of a prospective enzyme-linked immunosorbent assay (ELISA). A anti-neutrophil cytoplasm antibodies (ANCA-ELISA) test, typically used for diagnosing patients suffering from chronic inflammatory disorders in the skin, joints, blood vessels and other tissues is comparatively tested with a standard microplate reader and CSPT, yielding equivalent results at a fraction of the instrumental costs. The CSPT approach is discussed as a distributed measuring platform allowing decentralized measurements in routine applications, whereas keeping centralized information management due to its natural network embedded operation.  相似文献   

13.
One of the most fundamental properties of an enzyme is its selectivity, a property that has proved highly challenging to understand. Recent developments offer methodologies to rapidly establish activity-dependent profiles of enzymes. In this protocol, we describe methods to elucidate inhibitor fingerprints of enzymes. By taking advantage of well-defined small-molecule inhibitor libraries and the screening throughput offered from microplate and microarray platforms, we provide step-by-step application of the methodology toward the global characterization of metalloproteases, an important class of enzymes involved in numerous diseases and cellular processes. The same strategy is nonetheless applicable to virtually any given enzyme class, provided suitable experimental design and chemical inhibitor libraries are carefully implemented. We are able to routinely fingerprint as many as 2,000 independent enzyme interactions on the microplate platform within a span of approximately 7 h; however, the same throughput is attained within 5 h on the microarray platform.  相似文献   

14.
Several factors will influence the viability of a biochemical platform for manufacturing lignocellulosic based fuels and chemicals, for example, genetically engineering energy crops, reducing pre-treatment severity, and minimizing enzyme loading. Past research on biomass conversion has focused largely on acid based pre-treatment technologies that fractionate lignin and hemicellulose from cellulose. However, for alkaline based (e.g., AFEX) and other lower severity pre-treatments it becomes critical to co-hydrolyze cellulose and hemicellulose using an optimized enzyme cocktail. Lignocellulosics are appropriate substrates to assess hydrolytic activity of enzyme mixtures compared to conventional unrealistic substrates (e.g., filter paper, chromogenic, and fluorigenic compounds) for studying synergistic hydrolysis. However, there are few, if any, high-throughput lignocellulosic digestibility analytical platforms for optimizing biomass conversion. The 96-well Biomass Conversion Research Lab (BCRL) microplate method is a high-throughput assay to study digestibility of lignocellulosic biomass as a function of biomass composition, pre-treatment severity, and enzyme composition. The most suitable method for delivering milled biomass to the microplate was through multi-pipetting slurry suspensions. A rapid bio-enzymatic, spectrophotometric assay was used to determine fermentable sugars. The entire procedure was automated using a robotic pipetting workstation. Several parameters that affect hydrolysis in the microplate were studied and optimized (i.e., particle size reduction, slurry solids concentration, glucan loading, mass transfer issues, and time period for hydrolysis). The microplate method was optimized for crystalline cellulose (Avicel) and ammonia fiber expansion (AFEX) pre-treated corn stover.  相似文献   

15.
目的比较两种不同的NIH小鼠种群基因组DNA中H-2q单倍型的百分比,对重组基因乙型肝炎疫苗(酿酒酵母)、重组基因乙型肝炎疫苗(CHO)、重组基因乙型肝炎疫苗(汉逊酵母)和治疗性乙型肝炎疫苗(乙克)免疫应答的影响。方法检测乙肝疫苗免疫效力用酶标法,测定乙肝疫苗的ED50值,再通过微量细胞毒法和PCR方法检测小鼠的H-2单倍型,计算不同品系小鼠H-2q的百分数,得出乙肝疫苗与不同动物种群的相关性。结果经验证,经1号NIH小鼠检测结果证实,重组基因乙型肝炎免疫效力依次为CHO〉汉逊〉酿酒,疗性乙型肝炎疫苗(乙克)效力检测合格,但经2号NIH小鼠检测结果显示除CHO疫苗合格外,其他三种疫苗检测结果均为不合格。基因检测结果为,1号种群NIH鼠含有H-2q型基因的百分比是96%,而2号种群NIH小鼠含有H-2q型基因基因百分比为30%,因此不同的q型基因百分比导致了不同的检测结果。结论根据本研究结果表明虽然NIH鼠的H-2单倍型中有q型基因,但不同来源的小鼠种群之间会存在差异,经不同的环境饲养后,小鼠的基因会发生不同的变化,因此在进行生物制品检定时,要注意不同品系小鼠及同一品系小鼠不同种群之间的差异对试验本身的影响。建立一种"动物免疫"的概念。  相似文献   

16.
The receptor for advanced glycation endproducts (RAGE) is a multiligand receptor that binds a variety of structurally and functionally unrelated ligands, including advanced glycation endproducts (AGEs), amyloid fibrils, amphoterin, and members of the S100 family of proteins. The receptor has been implicated in the pathology of diabetes as well as in inflammatory processes and tumor cell metastasis. For the present study, the extracellular region of RAGE (exRAGE) was expressed as a soluble, C-terminal hexahistidine-tagged fusion protein in the periplasmic space of Escherichia coli. Proper processing and folding of the purified protein, predicted to contain three immunoglobulin-type domains, was supported by the results of electrospray mass spectroscopy and circular dichroism experiments. Sedimentation velocity experiments showed that exRAGE was primarily monomeric in solution. Binding to several RAGE ligands, including AGE-BSA, immunoglobulin light chain amyloid fibrils, and glycosaminoglycans, was demonstrated using pull-down, dot-blot, or enzyme-linked microplate assays. Using surface plasmon resonance, the interaction of exRAGE with AGE-BSA was shown to fit a two-site model, with KD values of 88 nM and 1.4 microM. The E. coli-derived exRAGE did not bind the advanced glycation endproduct Nepsilon-(carboxymethyl)lysine, as reported for the cellular receptor, and the possible role of RAGE glycosylation in recognition of this ligand is discussed. This new RAGE construct will facilitate detailed studies of RAGE-ligand interactions and provides a platform for preparation of site-directed mutants for future structure/function studies.  相似文献   

17.
The high cost of lignocellulolytic enzymes is one of the main barriers towards the development of economically competitive biorefineries. Enzyme engineering can be used to significantly increase the production rate as well as specific activity of enzymes. However, the success of enzyme optimization efforts is currently limited by a lack of robust high-throughput (HTP) cellulase screening platforms for insoluble pretreated lignocellulosic substrates. We have developed a cost-effective microplate based HTP enzyme-screening platform for ionic liquid (IL) pretreated lignocellulose. By performing in-situ biomass regeneration in micro-volumes, we can volumetrically meter biomass (sub-mg loading) and also precisely control the amount of residual IL for engineering novel IL-tolerant cellulases. Our platform only requires straightforward liquid-handling steps and allows the integration of biomass regeneration, washing, saccharification, and imaging steps in a single microtiter plate. The proposed method can be used to screen individual cellulases as well as to develop novel cellulase cocktails.  相似文献   

18.
Chemiluminescent reactions in mesoscale analytical structures (chips) containing micrometer-sized interconnecting channels and chambers (pL-nL total volume) were imaged. The chips were fabricated by bonding Pyrex glass to etched pieces of silicon using a high-temperature diffusive bonding technique. In initial experiments light emission from an enhanced chemiluminescent horseradish peroxidase reaction and from a peroxyoxalate reaction contained in straight channels (300 μm wide × 20μ deep; volume 70.2 nL) and open chambers (812 μm wide, 400 μm deep, 5.2 mm long) linked by channels (100μm wide, 20 μm deep) to an exit and entry port were studied using a specially modified microplate holder and an Amerlite microplate luminometer. Light emission from more complex structures (two chambers interconnected by a branching channel 100 μm wide, 20 μm deep) filled with a solution containing alkaline phosphatase, Emerald, and CSPDTM was imaged using a Photometrics Star 1 CCD camera. Detailed investigation of the detection and spatial resolution of the signal was performed on a Berthold Luminograph LB 980 using both the enhanced chemiluminescent horseradish peroxidase reaction and a peroxyoxalate reaction. We successfully resolved light emission from silicon structures with dimensions 100 μm wide and 20 μm deep. These simple silicon structures served as models for more complex designs that will be used for simultaneous multi-analyte assays in which an imaging system resolves and quantitates light emission from different locations on a silicon-glass analytical device.  相似文献   

19.
BackgroundA paper-based, multiplexed, microfluidic assay has been developed to visually measure alanine aminotransferase (ALT) in a fingerstick sample, generating rapid, semi-quantitative results. Prior studies indicated a need for improved accuracy; the device was subsequently optimized using an FDA-approved automated platform (Abaxis Piccolo Xpress) as a comparator. Here, we evaluated the performance of the optimized paper test for measurement of ALT in fingerstick blood and serum, as compared to Abaxis and Roche/Hitachi platforms. To evaluate feasibility of remote results interpretation, we also compared reading cell phone camera images of completed tests to reading the device in real time.Methods96 ambulatory patients with varied baseline ALT concentration underwent fingerstick testing using the paper device; cell phone images of completed devices were taken and texted to a blinded off-site reader. Venipuncture serum was obtained from 93/96 participants for routine clinical testing (Roche/Hitachi); subsequently, 88/93 serum samples were captured and applied to paper and Abaxis platforms. Paper test and reference standard results were compared by Bland-Altman analysis.FindingsFor serum, there was excellent agreement between paper test and Abaxis results, with negligible bias (+4.5 U/L). Abaxis results were systematically 8.6% lower than Roche/Hitachi results. ALT values in fingerstick samples tested on paper were systematically lower than values in paired serum tested on paper (bias -23.6 U/L) or Abaxis (bias -18.4 U/L); a correction factor was developed for the paper device to match fingerstick blood to serum. Visual reads of cell phone images closely matched reads made in real time (bias +5.5 U/L).ConclusionsThe paper ALT test is highly accurate for serum testing, matching the reference method against which it was optimized better than the reference methods matched each other. A systematic difference exists between ALT values in fingerstick and paired serum samples, and can be addressed by application of a correction factor to fingerstick values. Remote reading of this device is feasible.  相似文献   

20.
Glutathione S-transferases (GST) catalyzing the conjugation of reduced glutathione to a vast range of xenobiotics including insecticides were characterized in the whitefly Bemisia tabaci. GST activities were determined in susceptible and resistant strains of B. tabaci towards artificial substrates, i.e. 1-chloro-2,4-dinitrobenzene (CDNB) in a photometric microplate assay and monochlorobimane (MCB) in a fluoroemtric microplate assay and characterized by their Michaelis-Menten kinetics. The inhibitory potential of ethacrynic acid was very effective with IC50-values between 0.9 and 5.8 microM depending on substrate and strain. The inhibitory effect of dicumarol was 10 times lower. Glutathione-affinity chromatography purified GST enzymes of two different B. tabaci strains appeared as a single band on SDS-PAGE and had a molecular mass of 23.5 kDa determined by MALDI mass spectrometry. The N-terminus of the purified enzyme was sequenced by Edman degradation. The nearly full-length cDNA of the enzyme was isolated by RT-PCR using a degenerate primer derived from the N-terminal amino acid sequence and contained an open reading frame encoding a 194-amino-acid protein. Comparison of the deduced amino acid sequence with GSTs from other species revealed that the enzyme is closely related to insect class sigma GSTs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号