首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We describe the use of emulsion liquid membrane technology to perform chiral separations on low molecular weight species. We have reviewed liquid membrane technology in the context of existing process scale chiral separations. We illustrate the potential of this new technique by presenting our results on the selective extraction of phenylalanine enantiomers, using copper (II) N-decyl-(L)-hydroxyproline as a chiral selector in an emulsion liquid membrane configuration. This is compared with an analogous batch solvent extraction system. Initial batch enantiomeric excesses of greater than 40% were observed with the emulsion liquid membrane system compared with around 25% for the solvent extraction system. It was also noted that the system is not limited by the equilibrium capacity constraints of the solvent extraction system. We have shown that kinetic chiral liquid membrane technology offers high productivity and flexibility compared with analogous process scale chiral technologies. Recent transfer of highly specific chiral reversed-phase high-performance liquid chromatographic chemistries have shown that “one-stop” enantiomeric excesses of commercial interest (>95%) are achievable using kinetic chiral liquid membrane systems. Solvent and temperature selection strategies also have been outlined as means of increasing the enantioselectivity of existing liquid membrane extraction chemistries. Chirality 9:261–267, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

2.
The separation of enantiomeric sugars by chromatographic methods   总被引:1,自引:0,他引:1  
This paper has reviewed the number of chromatographic methods by which one may determine the absolute configuration of sugars. Both indirect methods (converting the enantiomeric pair into diastereomers) and direct methods (using chiral stationary phases) have been discussed. Resolving reagents for the indirect methods include chiral hydroxy compounds, chiral amines, and chiral thiols; with subsequent separation of the diastereomers either by gas-liquid chromatography or by high pressure liquid chromatography. Direct methods discussed have exclusively utilized chiral substitution of organopolysiloxane phases for the separation of enantiomeric sugars as volatile derivatives by gas-liquid chromatography.  相似文献   

3.
Proteins display interesting chiral discrimination properties owing to multiple possibilities of intermolecular interactions with chiral compounds. This review deals with proteins which have been used as immobilized chiral selectors for the enantioseparation of drugs in liquid chromatography and capillary electrophoresis. The main procedures allowing the immobilization of proteins onto matrices, such as silica and zirconia particles, membranes and capillaries are first presented. Then the factors affecting the enantioseparation of drugs in liquid chromatography, using various protein-based chiral stationary phases (CSPs), are reviewed and discussed. Last, chiral separations already achieved using immobilized protein selectors in affinity capillary electrochromatography (ACEC) are presented and compared in terms of efficiency, stability and reproducibility.  相似文献   

4.
This paper presents a systematic comparison of liquid chromatography (LC) and supercritical fluid chromatography (SFC) for Chiralcel OD and Chiralpak AD chiral stationary phases (CSPs), performed using various chiral compounds having a known or potential pharmaceutical activity. The chiral recognition mechanisms involved in LC and SFC for the enantiomeric separation of β-blockers have been studied more particularly. As a general rule, it appears that the presence of polar functions, like primary or secondary hydroxyl or amine functions, may result in marked discrepancies in selectivity between LC and SFC. This result is peculiar to cellulose- and amylose-derived CSPs, for which the interactions involved in chiral recognition mechanism are not always well balanced, contrary to what happens for independent CSPs. In the case of chiral resolution of polar solutes or polymer-type CSPs, the analyst should try both the LC and SFC techniques to be able to choose the more stereoselective one. © 1995 Wiley-Liss, Inc.  相似文献   

5.
Very great advances have been made in the field of direct optical resolution of organic compounds by chromatographic techniques. Chiral capillary gas chromatography now permits a determination of the enantiomeric composition of a few nanograms of a compound present in a mixture of many others. Coupled with high resolution mass spectrometry the technique will additionally permit structural elucidation; of great interest in pheromone research and related areas. Analytical separations of enantiomers are now also carried out by high-performance liquid chromatography (HPLC) methods based on a variety of principles. Basically, two main types are used, differing as to whether the mobile phase has to be a chiral medium or not. Two-dimensional HPLC, whereby compounds separated on a non-chiral column are progressively and automatically transferred to a chiral column for optical resolution, has been used successsfully for chiral amino acid separations. Many different chiral sorbents for preparative LC and HPLC resolutions have been prepared; some of these are now used in columns capable of producing pure enantiomers from a given racemate at a rate of the order of one gram/hour in continuous, automatic HPLC procedures. Apart from all important applications of these results of optical resolution technology, an increased knowledge of the underlying chiral recognition phenomena responsible for enantioselection has also been achieved.  相似文献   

6.
The enantiomeric excess of chiral starting materials is one of the important factors determining the enantiopurity of products in asymmetric synthesis. Fifty‐one commercially available chiral reagents used as building blocks, catalysts, and auxiliaries in various enantioselective syntheses were assayed for their enantiomeric purity. The test results were classified within five impurities level (ie, <0.01%, 0.01%‐0.1%, 0.1%‐1%, 1%‐10%, >10%). Previously from 1998 to 2013, several reports have been published on the enantiomeric composition of more than 300 chiral reagents. This series of papers is necessitated by the fact that new reagents are forthcoming and that the enantiomeric purity of the same reagent can vary from batch to batch and/or from supplier to supplier. This report presents chiral liquid chromatography (LC) and gas chromatography (GC) methods to separate enantiomers of chiral compounds and evaluate their enantiomeric purities. The accurate and efficient LC analysis was done using newly introduced superficially porous particle (SPP 2.7 μm) based chiral stationary phases (TeicoShell, VancoShell, LarihcShell‐P, and NicoShell).  相似文献   

7.
The enantiomers of mandelic acid and its analogs have been chromatographically separated on a chiral stationary phase (CSP) derived from 4‐(3,5‐dinitrobenzamido) tetrahydrophenanthrene. The rationale of separations of these compounds is discussed with respect to the method development for determining enantiomeric purity and possibility of obtaining enantiomerically pure materials by high‐pressure liquid chromatography. The relationship of analyte structure to the extent of enantiomeric separation has been examined and separation factors (α) are presented for various groups of structurally related compounds. Chiral recognition models have been suggested to account for the observed separations. These models provide mechanistic insights into the chiral recognition process. Chirality 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

8.
A technique based exclusively on chiral reversed-phase liquid chromatography has been shown to greatly facilitate studies of enantioselectivity in lipase-catalyzed hydrolysis of chiral organic esters. Only two sets of experimental data are needed to calculate the enantioselectivity (E) of a kinetically controlled enantiomer-differentiating reaction of this kind, viz. the enantiomeric excess of the product (eep) or substrate (ees), and the degree of substrate conversion (c). The product enantiomers are well separated on a BSA-based column, giving eep directly. In addition, separation of the (unresolved) ester substrate from the enantiomeric products gives c by integration. Via an optimization of the mobile phase used in the chiral chromatographic system, both these parameters can often be determined in a single run. Highly precise and detailed kinetic studies of the enzymatic reaction can thus be performed. In this way, E-values have been determined for a series of 2-chloroethyl 2-arylpropanoates hydrolyzed in the presence of a Candida cylindracea lipase at pH 6.0 and 7.1. Effects on the E-values from a partial purification and further processing of the lipase have also been studied.  相似文献   

9.
Tan HM  Soh SF  Zhao J  Yong EL  Gong Y 《Chirality》2011,23(Z1):E91-E97
Two new types of methylcalix[4]resorcinarene-bonded stationary phases, (3-(C-methylcalix[4]resorcinarene)-2-hydroxypropoxy)-propylsilyl-appended silica particles (MCR-HPS) and bromoacetate-substituted MCR-HPS particles (BAMCR-HPS), have been synthesized and used as chiral stationary phases for high-performance liquid chromatography (HPLC) for the first time. The synthetic stationary phases are characterized by means of elemental analysis and Fourier-transform infrared spectroscopy. The chromatographic behavior of MCR-HPS and BAMCR-HPS was studied with several disubstituted benzenes and some chiral drug compounds under both normal phase and reversed-phase conditions. The results show that MCR-HPS has excellent selectivity for the separation of aromatic positional isomers and BAMCR-HPS exhibits excellent performance for separation of enantiomers of chiral compounds.  相似文献   

10.
The direct enantiomeric separation of a series of beta-blockers has been carried out on two chiral stationary phases (CSPs) derived from 3,5-dinitrobenzoyl tyrosine: the commercially available ChyRoSine-A and a recent improved version of this CSP. Using supercritical fluid chromatography (SFC), facile separations are achieved (1.1 less than Rs less than 7) within short analysis times. The parameters affecting the enantioselectivity (temperature, pressure, mobile phase nature, solute structure) have been investigated. The optimal mobile phase consists in a mixture of carbon dioxide-methanol-propylamine at 25 degrees C. The solute structure has a great influence on the enantioselectivity. For instance, both amine and hydroxyl protons are necessary for chiral discrimination to occur. Furthermore, the steroselectivity value is directly connected to the amine substituent steric bulkiness. Surprisingly, these solutes are poorly resolved using normal phase liquid chromatography (NPLC). Accordingly, the specific influence of carbon dioxide on the enantiomeric separation of 1,2-amino-alcohols have been investigated using various techniques such as nuclear magnetic resonance (NMR) or molecular modelisation. It has been shown that carbon dioxide acts as a complexing agent toward the amino-alcohol by setting up of a bridge with the hydroxyl and the amine protons of the solute. In that way, the resulting complex possesses lower acido-basic properties and a higher conformational rigidity, responsible for chiral discrimination.  相似文献   

11.
The polysaccharide-based chiral packing materials (CPMs) for high-performance liquid chromatography (HPLC) have been recognized as the most powerful ones for the analyzing and preparative separating of the chiral compounds. These CPMs have been conventionally prepared by coating polysaccharide derivatives on a silica gel support. This means that the solvents, which swell or dissolve the derivatives on the silica gel and reduce the performance of the chiral columns, do not allow to be applied as components of the eluents. Therefore, the polysaccharide-based CPMs can be used with a rather limited number of eluents. In order to enhance the versatility of the eluent selection for more practical and economical chromatographic enantioseparations, the polysaccharide derivatives must be immobilized onto the silica gel. This review summarizes our latest studies on the development of the immobilized-type CPMs via the radical copolymerization and the polycondensation of the polysaccharide derivatives bearing small amounts of vinyl groups and alkoxysilyl groups, respectively.  相似文献   

12.
Bozkurt S  Yilmaz M  Sirit A 《Chirality》2012,24(2):129-136
Novel chiral calix[4]arene derivatives bearing amino alcohol moieties at the lower rim have been synthesized from the reaction of p-tert-butylcalix[4]arene diester with various amino alcohols. The transport of amino acid esters (phenylglycine, phenylalanine, and tryptophan methyl esters hydrochloride) and mandelic acid were studied through chloroform bulk liquid membrane system using chiral calix[4]arenes 15-20. All these receptors have been found to act as carriers for transport of aromatic amino acid methylesters and mandelic acid from the aqueous source phase to the aqueous receiving phase. The influence of calixarene and guest structures upon transport through liquid membrane is discussed.  相似文献   

13.
In chiral separation, enantioseparation factor is an important parameter which influences the resolution of enantiomers. In this current overview, a biphasic chiral recognition method is introduced to the readers. This method can significantly improve the enantioseparation factor in two‐phase solvent through adding lipophilic and hydrophilic chiral selectors which have opposite chiral recognition ability to organic and aqueous phases, respectively. This overview presents the development and applications of biphasic chiral recognition in liquid‐liquid extraction and counter current chromatography. It mainly focuses on the topics of mechanism, advantages and limitations, applications, and key factors of biphasic chiral recognition. In addition, the future outlook on development of biphasic chiral recognition also has been discussed in this overview.  相似文献   

14.
Almost half of the drugs in use today are chiral. It is well established that the pharmacological activity is mostly restricted to one of the enantiomers (eutomer). There can be qualitative and quantitative differences in the activity of the enantiomers. In many cases, the inactive enantiomer (distomer) shows unwanted side effects or even toxic effects. Even if the side effects are not that drastic, the distomer has to be metabolized and this represents an unnecessary burden for the organism. Therefore, the development of methods for the separation of enantiomers, both on analytical and preparative scale, has become increasingly important. Chromatographic techniques such as thin layer chromatography (TLC), gas chromatography (GC), supercritical fluid chromatography (SFC), and above all high-performance liquid chromatography (HPLC) have been used for enantiomer separation for about two decades. More recently, electromigration techniques, such as capillary electrophoresis and capillary electrochromatography, have been shown to be powerful alternatives to chromatographic methods. This review gives a short overview of different chiral separation principles and their application. Several new developments are discussed.  相似文献   

15.
Chromatographic applications of three novel chiral stationary phases (CSPs) deriving from (S)-(N)-(3,5-dinitrobenzoyl)tyrosine are reported, under liquid chromatographic (LC) and subscritical fluid chromatographic (SubFC) conditions. Two grafting modes of the chiral moiety have been experimented starting either from γ-mercaptopropyl-silanized (type 1) or γ-aminopropyl-silanized (type 2) silica gels. For type 2 CSPs an evaluation of the stability of the amide linkage was achieved by means of SubFC; the relative contriution of ionic and covalent bindings to the ciral recognitio aility was then outlined. The chromatographic properties of these CSPs were compared with those of the corresponding CSPs deriving from phenylglycine, p-hydroxyphenylglycine, and phenylalanine for the resolution of some tertiary phosphine oxide, naphthoyl amide, and α-methylene γ-lactam enantiomers. Some simple requirements regarding the solute and CSP structures for chiral recognition ability can be inferred from these results. In addition, the resolutio of π-acid α-N-(3,5-dinitrobenzoyl)amino esters was investigated on these π-acid CSPs. An example of preparative scale chromatography is also presented.  相似文献   

16.
Up to now, some chiral metal‐organic frameworks (MOFs) have been reported for enantioseparation in liquid chromatography. Here we report a homochiral MOF, [Cd2(d‐cam)3]·2Hdma·4dma, used as a new chiral stationary phase for high‐performance liquid chromatographic enantioseparation. Nine racemates of alcohol, naphthol, ketone, and base compounds were used as analytes for evaluating the separation properties of the chiral MOF packed column. Moreover, some effects such as mobile phase composition, column temperature, and analytes mass for separations on this chiral column also were investigated. The relative standard deviations for the resolution values of run‐to‐run and column‐to‐column were less than 2.1% and 3.2%, respectively. The experimental results indicate that the homochiral MOF offered good recognition ability, which promotes the application of chiral MOFs use as stationary phase for enantioseparation. Chirality 28:340–346, 2016. © 2016 Wiley Periodicals, Inc.  相似文献   

17.
Enantioselective segregation has been attained in the Bx phase of a novel substituted oxadiazole achiral banana-shaped liquid crystal (LC) without introducing any chiral species. This bent-core molecule exhibits LC polymorphism; the higher temperature nematic (N) phase and the lower temperature banana smectic phase (Bx phase), in which spontaneous chiral segregation with (+) and (-) chiral domains occurs with equal probabilities. In twisted cell geometries, extrinsically induced twisted N structures are formed and result in intrinsically chiral conglomerate when the temperature is decreased from N to Bx. The observed optical activity in homochiral Bx phase is comparable to those theoretically predicted and is proportional to the cell thickness.  相似文献   

18.
Investigation of individual drug enantiomers is required in pharmacokinetic and pharmacodynamic studies of drugs with a chiral centre. Cyclodextrins (CDs) are extensively used in high-performance liquid chromatography as stationary phases bonded to a solid support or as mobile phase additives in HPLC and capillary electrophoresis (CE) for the separation of chiral compounds. We describe here the basis for the liquid chromatographic and capillary electrophoretic resolution of drug enantiomers and the factors affecting their enantiomeric separation. This review covers the use of CDs and some of their derivatives in studies of compounds of pharmacological interest.  相似文献   

19.
Self-assembly plays an important role in the formation of many chiral biological structures and in the preparation of chiral functional materials. Therefore the control of chirality in synthetic or biological self-assembled systems is important either for the comprehension of recognition phenomena or to obtain materials with predictable and controllable properties. Circular dichroism was developed to study molecular chirality, however, because of its outstanding sensitivity to chiral perturbations of the system under investigation; it has been extended more recently to supramolecular chemistry. In particular, self-assembly processes leading to the formation of chiral supramolecular architectures (and eventually to gels or liquid crystal phases) can be monitored by CD. Furthermore, CD spectroscopy often allows one to obtain structural information on the assembled structures. This review deals with representative contributions to the study of supramolecular chirality by means of circular dichroism.  相似文献   

20.
The characterization of the drug metabolism and pharmacokinetic (DMPK) profiles of stereoisomers is a fundamental aspect of the drug discovery and development processes. Therefore, chiral drug bioassays are very important to pharmaceutical and biomedical researchers. The recent developments in chiral liquid chromatography coupled to atmospheric pressure ionization tandem mass spectrometry (LC-API-MS/MS) for the analysis of pharmaceuticals are reviewed. Various ionization techniques including electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric photoionization (APPI) interfaced with chiral liquid chromatographic methods are described in terms of their ionization efficiencies, matrix effects and limitations. Examples were selected to demonstrate the applicability of these methods for enantioselective bioanalysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号