首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Endocrine practice》2015,21(2):128-135
ObjectiveUltrasound-guided core needle biopsy (UG-CNB) is a procedure that is often performed either after repeated inadequate or nondiagnostic ultrasound-guided fine-needle aspiration (UG-FNA) or in combination with UG-FNA in the evaluation of thyroid nodules. The purpose of this study was to compare the efficacy and safety of UG-CNB and UG-FNA for evaluating thyroid nodules.MethodsThis was a retrospective study of 350 consecutive patients who had thyroid nodules biopsied by UG-CNB or UG-FNA from January 2007 until November 2011 at our institution. Biopsy results were compared to the surgical specimen pathology reports for the 105 patients who subsequently underwent hemi- or total thyroidectomy in order to determine whether UG-CNB has advantages over UG-FNA for diagnosing thyroid malignancy and neoplasia.ResultsOut of 461 thyroid nodules biopsied from 350 patients, 365 (79%) involved UG-CNB and 96 (21%) involved UG-FNA. The UG-FNA biopsy group had a significantly higher rate of inadequate sampling than the UG-CNB group (P < .0001; Fisher’s exact test). Out of 365 UG-CNB samples, 6 (2%) were deemed inadequate for histologic diagnosis, whereas 26 (27%) of the 96 UG-FNA samples were considered inadequate for cellularity. Comparison of biopsy results with the surgical specimen pathology reports revealed that the diagnostic accuracy of UG-CNB and UG-FNA for detecting malignancy was similar, at 89 and 94%, respectively (not significant by Fisher’s exact test). However, the UG-CNB group had a higher detection rate for benign follicular lesions compared to the UG-FNA group (65% versus 48% for UG-FNA; P = .002). Although UG-FNA detected neoplasia with high sensitivity (100%), the specificity was poor (30%). Neither biopsy group had any significant immediate or delayed procedure-related complications.ConclusionOur study demonstrated that UG-CNB is safe and is less likely to result in a nondiagnostic biopsy. The accuracy of the UG-CNB technique is similar to that of UG-FNA for detecting thyroid malignancy. (Endocr Pract. 2015;21:128-135)  相似文献   

2.
《Endocrine practice》2016,22(6):679-688
Objective: This study evaluated the prevalence of nondiagnostic results, diagnostic performance, and complications of core-needle biopsy (CNB) compared with repeat fine-needle aspiration (FNA) for thyroid nodules with previous nondiagnostic FNA findings.Methods: The Ovid-MEDLINE and EMBASE databases were thoroughly searched for studies evaluating CNB or repeat FNA for thyroid nodules with initially nondiagnostic FNA results. Pooled proportions of nondiagnostic results of CNB and repeat FNA were calculated. A meta-analysis was performed to evaluate the diagnostic accuracy of CNB and repeat FNA for a diagnosis of malignancy using a bivariate random-effects model. Complication rates were also evaluated.Results: A review of 52 articles identified 4 eligible articles, involving 1,028 patients with 1,028 thyroid nodules, which were included in the meta-analysis. CNB demonstrated significantly lower rates of nondiagnostic results (6.4%) than repeat FNA (36.5%) (P<.0001). In the 3 studies that analyzed the diagnostic accuracy of CNB in diagnosing malignancy, CNB demonstrated significantly higher summary estimates of sensitivity (89.8%) than repeat FNA (60.6%) (P = .022), but summary specificity did not differ between CNB (99.2%) and repeat FNA (99.0%) (P = .576). None of the patients who underwent CNB or repeat FNA experienced any major complications.Conclusion: CNB demonstrates lower rates of nondiagnostic results and higher diagnostic accuracy than repeat FNA. CNB, rather than repeat FNA, can be utilized to diagnose thyroid nodules previously nondiagnostic on FNA.Abbreviations:CI = confidence intervalCNB = core-needle biopsyFNA = fine-needle aspirationSROC = summary receiver operating characteristicUS = ultrasound  相似文献   

3.
《Endocrine practice》2010,16(6):986-991
ObjectiveTo determine whether a difference exists in terms of obtaining adequate cytologic samples from ultrasound-guided fine-needle aspiration cytology (US-FNAC) between experienced and inexperienced physicians in a tertiary referral center.MethodsIn a prospective design, all patients with thyroid nodules of at least 10 mm in diameter were referred for US-FNAC tissue sampling as a part of their diagnostic work-up. Between May 2006 and September 2009, 997 euthyroid patients with 1, 320 thyroid nodules were referred for US-FNAC by the attending endocrinologist (experienced physician) or 1 of 2 endocrinology fellows (inexperienced physicians).ResultsOf the 1, 320 nodules, 713 biopsy specimens were obtained by the experienced physician and 607 were obtained by the inexperienced physicians. Nodule size was significantly larger in the endocrinologist’s group of patients than in the fellows’ group of patients (17 mm versus 14 mm, respectively; P < .001). The inadequacy rate of the US-FNAC procedures performed by the experienced physician (22 of 713 thyroid nodules or 3.1%) was significantly lower than for those performed by the inexperienced physicians (102 of 607 thyroid nodules or 16.8%) (P < .001).ConclusionWe conclude that, with increasing operator experience, the number of inadequate cytologic specimens generated by US-FNAC procedures is substantially reduced. This limits both direct and indirect costs and also minimizes the risks of possibly unnecessary surgical procedures. (Endocr Pract. 2010;16:986-991)  相似文献   

4.

Background

Fine-needle aspiration biopsy (FNAB) is a recognized technique for the basic, preoperative cytological diagnosis of thyroid nodules.

Aim of the Study

To analyze the accuracy of FNAB in the diagnosis of thyroid cancer in patients with solitary and multiple thyroid nodules and to compare the demographic, clinical and pathological characteristics of patients with thyroid carcinoma in solitary and multiple tumors.

Materials and Methods

The case records of 2,403 patients with solitary and multiple thyroid tumors treated consecutively between 2008 and 2013 were analyzed retrospectively. We selected 1,645 for further analysis. A solitary thyroid nodule was observed in 493 patients, and multiple nodules were detected in 1,152 patients. Further classification of the patients in these two groups was performed on the basis of the FNAB results, type of surgery performed and histopathology. TC was histopathologically confirmed in 166 patients, and benign disease was found in 1,479. The TC patients were assigned to the study group, and those with benign thyroid disease were placed into the control group. The study group was divided into two subgroups according to the presence of cancer in a single thyroid nodule or in multiple nodules. Malignancy in a solitary thyroid nodule was diagnosed in 98 (59.0%) patients, and cancer in multiple nodules was diagnosed in 68 (41.0%). Comparative analyses of the demographic, clinical and histopathological characteristics were performed for both subgroups. The following statistical analyses were performed: comparative characteristic of subgroups, ROC analysis for study group and subgroup of patients, and multivariable logistic regression analysis for study group.

Results

The rate of prediction of TC by FNAB was three times higher in the patients with a solitary thyroid nodule compared with those with multiple thyroid nodules and it was statistically significant (p<0.001). The rate of total thyroid resection and lack of necessity for reoperation were also significantly higher in the TC patients with a solitary nodule. The histopathological results showed that significantly more patients with a solitary nodule had advanced-stage TC (stage III or IV) and tumor progression (pT3 or pT4) (p = 0.002 for both). ROC analysis demonstrated that the overall accuracy of FNAB as a predictor of thyroid cancer presence was high, especially for the subgroup of patients with a solitary thyroid nodule (AUC = 0.958, p<0.0001). Multivariable logistic regression analysis confirmed that a positive FNAB result was the sole predictor of the performance of total resection in the TC study group (p<0.0001), while a negative FNAB result and the presence of a papillary cancer type were independent predictors of the risk of reoperation (p<0.0001 and p = 0.002, respectively).

Conclusions

FNAB often produces false-negative results in patients with multiple malignant thyroid tumors, which results in reoperation in many cases. False-negative FNAB results are rare in patients with a solitary tumor. Because of the low predictive capacity of FNAB for thyroid cancer in patients with multiple thyroid tumors, total thyroid excision should be considered in most cases despite a "negative" (no malignant) FNAB result.  相似文献   

5.
《Endocrine practice》2007,13(7):735-742
ObjectiveTo assess the value of repeating a biopsy when the initial thyroid fine-needle aspiration (FNA) biopsy is nondiagnostic.MethodsBetween 1990 and 2003, 4,311 thyroid FNAs were performed at the Cleveland Clinic Foundation, of which 220 (5%) were nondiagnostic. Among 189 patients whose medical records were available for retrospective review, 106 underwent a repeated FNA (FNA #2), and 14 had a second repeated FNA (FNA #3). Thyroid ultrasonography was used in the evaluation in 113 FNAs.ResultsThe first and second repeated FNAs were diagnostic in 58% (62 of 106 patients) and 50% (7 of 14 patients), respectively. The rate of malignant disease in patients with no repeated FNAs versus 1 or more repeated FNAs was 4.8% (4 of 83) versus 11.3% (12 of 106), respectively. Ultrasound-guided FNA yielded a diagnosis among 33 of 113 biopsies (29.2%), and FNA without ultrasound guidance provided a diagnosis in 30 of 159 biopsies (18.9%). Thus, the use of thyroid ultrasonography significantly improved the likelihood of establishing a diagnosis (P = 0.017). We found that repeating the FNA up to 2 times provides a diagnosis in up to 60% of cases.ConclusionThe overall prevalence of thyroid cancer in patients with nondiagnostic FNA is not trivial—8.5% in our study group of 189 patients. An aggressive approach toward nondiagnostic FNA biopsies is recommended, with performance of at least 2 repeated FNA biopsies, preferably with the help of ultrasound guidance. (Endocr Pract. 2007;13:735-742)  相似文献   

6.
《Endocrine practice》2004,10(4):317-323
ObjectiveTo evaluate the approach of endocrinologists in the setting of nondiagnostic thyroid fine-needle aspiration (FNA) biopsies.MethodsIn 2002, we surveyed physicians attending the national annual meetings of the American Association of Clinical Endocrinologists and the Endocrine Society of North America, using a 13-item questionnaire. The responses were tallied and analyzed.ResultsOf the 143 respondents, 139 were endocrinologists, with a male:female ratio of 2.5:1. Most respondents were involved in a medical practice in North America, but Europe, Asia, New Zealand, and Australia were also represented. Of those performing thyroid FNA biopsy, 31% used thyroid ultrasound guidance. Among the survey respondents, 16%, 49%, 20%, and 15% performed less than 2, 2 to 5, 6 to 10, and more than 10 thyroid FNA biopsies per month, respectively. Among the respondents, 13.5%, 44%, 28.5%, 10%, and 4% had nondiagnostic rates of less than 5%, 5 to 10%, 11 to 20%, 21 to 30%, and more than 30%, respectively. The approach of the respondents to an initially nondiagnostic FNA was repeated FNA biopsy in 87%, observation in 7%, levothyroxine suppression in 4%, and thyroid scintigraphy in 2%. Respondents believed that the most cost-effective approach in a patient with nondiagnostic FNA was repeated biopsy (82%), monitoring the size of the thyroid nodule (17%), and surgical referral (< 1%). No one was willing to repeat the thyroid biopsy more than three times.ConclusionOn the basis of findings in our survey, most endocrinologists repeat thyroid FNA at least once when confronted with a nondiagnostic result. No published studies have demonstrated the cost-effectiveness of this approach versus proceeding to surgical intervention or observation. We hope that this survey will encourage further studies on this issue. (Endocr Pract. 2004;10: 317-323)  相似文献   

7.

Background

Thyroid cancer is the most common endocrine gland malignancy and fine-needle aspiration biopsy is widely used for thyroid nodule evaluation. Repeated aspiration biopsies are needed due to plausible false-negative results. This study aimed to investigate the overall relationship between aspiration biopsy and thyroid cancer diagnosis, and to explore factors related to shorter diagnostic time.

Methods

This nationwide retrospective cohort study retrieved data from the Longitudinal Health Insurance Database in Taiwan. Subjects without known thyroid malignancies and who received the first thyroid aspiration biopsy after 2004 were followed-up from 2004 to 2009 (n = 7700). Chi-square test, Kaplan-Meier survival analysis, and Cox proportional hazards model were used for data analysis.

Results

Of 7700 newly-aspirated patients, 276 eventually developed thyroid cancer (malignancy rate 3.6%). Among the 276 patients with thyroid cancer, 61.6% underwent only one aspiration biopsy and 81.2% were found within the first year after the initial aspiration. Cox proportional hazards model revealed that aspiration frequency (HR 1.07, 95% CI 1.06–1.08), ultrasound frequency (HR 1.02, 95% CI 1.01–1.03), older age, male sex, and aspiration biopsies arranged by surgery, endocrinology or otolaryngology subspecialties were all associated with shorter time to thyroid cancer diagnosis.

Conclusions

About 17.4% of thyroid cancer cases received more than two aspiration biopsies and 18.8% were diagnosed one year after the first biopsy. Regular follow-up with repeated aspiration or ultrasound may be required for patients with clinically significant thyroid nodules.  相似文献   

8.
《Endocrine practice》2015,21(11):1219-1226
Objective: Major problems of fine-needle aspiration (FNA) of thyroid nodules arise due to nondiagnostic results caused by inadequately obtained FNA specimens. The purpose of this study was to evaluate the value of visual assessment of liquid-based cytology specimens during FNA of thyroid nodules for predicting sampling adequacy.Methods: For 3 months, visual assessment of FNA specimens was used for 534 consecutive nodules in 534 patients. The FNA specimens were visually graded immediately following aspiration for each nodule, and the visual grades were classified into 2 categories: inadequate (<6 cell groups) and adequate (>6 cell groups). The cytology results were classified as diagnostic or nondiagnostic based on the Bethesda system. We compared the ultrasound features and FNA characteristics between the diagnostic and nondiagnostic results. Multiple logistic regression analysis was used to determine factors independently predictive of nondiagnostic results. We also evaluated the interobserver agreement regarding the visual assessment.Results: Visual assessment was feasible in all patients, and the nondiagnostic rate was 11.6% (62 of 534). Nondiagnostic results were more frequent in the inadequate visual assessment group (38.1%) than in the adequate visual assessment group (10.5%) (P = .001). Independent predictive factors for nondiagnostic results were inadequate visual assessment (odds ratio, 5.18), >50% vascularity (odds ratio, 3.98), and macrocalcification (odds ratio, 3.60). Interobserver agreement for the prediction of visual assessment was good (κ value, 0.767; P<.001).Conclusion: Immediate visual assessment of a specimen during FNA of a thyroid nodule is a feasible method for predicting sampling adequacy.Abbreviations: FNA = fine-needle aspiration LBC = liquid-based cytology US = ultrasound  相似文献   

9.
《Endocrine practice》2020,26(9):1017-1025
Objective: We investigated patients who were referred to our institution after fine-needle aspiration (FNA) was performed at outside clinics to evaluate how many nodules satisfied the FNA indications of the Korean Thyroid Imaging Reporting and Data System (K-TIRADS) and compare that to the number of thyroid nodules that satisfy the FNA indications of the American College of Radiology (ACR)-TIRADS and American Thyroid Association (ATA) guidelines.Methods: Between January 2018 and December 2018, 2,628 patients were included in our study. The included patients were those referred for thyroid surgery after having a suspicious thyroid nodule. We retrospectively applied the three guidelines to each thyroid nodule and determined whether each nodule satisfied the FNA indications. We compared the proportion of nodules satisfying the FNA indications of each guideline using a generalized linear model and generalized estimating equation.Results: The median size of the 2,628 thyroid nodules was 0.9 cm (range, 0.2 to 9.5 cm). We found that FNA was not indicated for 54.1%, 47.7%, and 19.1% of nodules and 87.3%, 99.0%, and 97.8% among them were micronodules (<1 cm) according to the ACR-TIRADS, ATA guideline, and K-TIRADS, respectively. The proportion of micronodules which satisfied the FNA indications was significantly higher for the K-TIRADS (65.1%) compared to the ACR TIRADS (12.1%) and ATA guideline (12.1%) (P<.001).Conclusion: Among patients referred for thyroid surgery to our institutions, about 35% of the micronodules underwent FNA despite not being appropriate for indications by the K-TIRADS. Systematic training for physicians as well as modifications to increase the sensitivity of the guideline may be needed to reduce the overdiagnosis of thyroid cancers, especially for micronodules.  相似文献   

10.
《Endocrine practice》2008,14(2):224-228
ObjectiveTo describe an elusive case of blastomycosis involving the thyroid gland, which was ultimately diagnosed by use of ultrasound-guided fine-needle aspiration (FNA).MethodsWe present a case report, including clinical features, results of laboratory studies, and radiographic, computed tomographic, and ultrasonographic findings. In addition, the treatment and the utility of FNA of the thyroid relative to the diagnosis of blastomycosis are discussed.ResultsAn 18-year-old woman with no significant past medical history and with a competent immune system presented initially to her family physician because of headaches, lymphadenopathy, blurry vision, and fatigue. Radiography of the chest showed findings considered consistent with pneumonia, for which amoxicillin was prescribed. Subsequently, an ophthalmologist diagnosed anterior uveitis and initiated topical corticosteroid therapy. Worsening symptoms prompted performance of computed tomography of the chest, which suggested thyroid involvement. Ultimately, FNA of a thyroid nodule led to the cytologic diagnosis of blastomycosis. The patient was treated successfully with amphotericin for blastomycosis of the eye, lung, and thyroid.ConclusionPhysicians should consider the potential presence of blastomycosis when a lung lesion does not improve with typical treatment interventions. Disseminated blastomycosis can be diagnosed with use of FNA of the thyroid. (Endocr Pract. 2008;14:224-228)  相似文献   

11.
《Endocrine practice》2015,21(6):595-603
Objective: The major limitation of ultrasound-guided fine-needle aspiration biopsy (US-FNAB) procedures of thyroid nodules are the cytologically nondiagnostic results. The role of increasing the diameter of the needle in the third FNAB (FNAB#3) due to inadequate cytology has as yet not been investigated. The aim of the present study was to evaluate whether increasing the needle diameter could improve the cytologic sampling of thyroid nodules following 2 previous nondiagnostic US-FNAB results.Methods: Between July 2012 and December 2012, 140 consecutive patients with 2 prior nondiagnostic US-FNAB results were enrolled in this prospective investigation. Group 22G consisted of 70 patients (78.5% women; mean age, 52 years) having nodules examined with a 22-gauge (G) needle. Group 27G consisted of 70 patients (75.7% women; mean age, 53 years) having nodules examined with a 27-G needle.Results: The rate of nondiagnostic FNAB results was 42.8% (30 of 70) in group 22G and 64.3% (45 of 70) in group 27G, which was a significant difference (P = .011). The large-bore (22 G) needle was found to be statistically significantly superior compared with the small-bore (27 G) needle in diagnostic ability for predominantly solid (P = .014), irregular (P = .013), and halo-free (P = .021) nodules. The accuracy rate was 64.6 and 38% for large-bore (22 G) and small-bore (27 G) needles, respectively.Conclusion: The results of our study showed that increasing the needle lumen diameter significantly improves diagnostic performance in terms of adequate aspirated material and diagnostic accuracy rate following 2 prior nondiagnostic US-FNABs.Abbreviations: AUS = atypia of undetermined significance FNAB = fine-needle aspiration biopsy G = gauge NPV = negative predictive value PPV = positive predictive value US = ultrasound  相似文献   

12.
《Endocrine practice》2011,17(5):699-706
ObjectiveTo assess the impact of correlating findings from iodine I 123 (123I) radionuclide scans and thyroid ultrasonography on the decision to perform fine-needle aspiration (FNA) biopsy of thyroid nodules.MethodsIodine 123 scans and sonographic images of adult patients who had both examinations performed within 6 months of each other at our institution were retrospectively reviewed. The presence of 1 or more nodules satisfying imaging-specific criteria for recommending FNA biopsy was recorded. Iodine 123 scan and sonographic images were then directly compared to determine how frequently the FNA recommendation would be affected by discordant findings.ResultsThe study included 97 adult patients, with a total of 291 thyroid lobes (right thyroid lobe, left thyroid lobe, and isthmus). Recommendations for FNA biopsy were concordant in 231 of 291 lobes (79.4%), with both modalities recommending FNA biopsy in 55 lobes and not recommending FNA biopsy in 176 lobes. A discordant recommendation occurred in 60 of 291 lobes (20.6%). Using only ultrasonography findings, a recommendation for FNA biopsy was not indicated for 11 of the 291 lobes (3.8%) with functioning nodules. Using only 123I findings, a recommendation for FNA biopsy was not indicated for 23 of the 291 lobes (7.9%); 13 had nodules, but none that fulfilled sonographic criteria, and 10 had no identifiable nodule on ultrasonography. Iodine 123 scan did not identify 26 lobes with nodules (8.9%) for which FNA biopsy was recommended based on ultrasonography findings.ConclusionRecommendations for FNA biopsy should not be based on the presence of hypofunctioning regions on 123I scan without sonographic confirmation. (Endocr Pract. 2011;17:699-706)  相似文献   

13.
《Endocrine practice》2013,19(5):769-779
ObjectiveThe diagnostic value of calcitonin measurement in fine-needle aspiration biopsy (FNAB) washout fluid (Ct-FNAB) for medullary thyroid cancer (MTC) remains to be determined. This prospective study aimed to assess the diagnostic value of Ct-FNAB in thyroid nodules in comparison with basal serum calcitonin (Ct), pentagas- trin-stimulated Ct (Pg-sCt), and cytology.MethodsAmong patients with goiter addressed with US-FNAB who had an initial clinical suggestion for thyroidectomy, 27 patients with thyroid nodule/s (n = 60) and normal, borderline, or increased Ct fulfilled the criteria for thyroidectomy. All 27 patients (enrolled according to exclusion/inclusion criteria) underwent ultrasonography (US), Ct, Pg-sCt, US-assisted FNAB of each patient’s nodule for both cytology, and Ct-FNAB before thyroidectomy.ResultsCt-FNAB always resulted in >1,000 pg/mL in MTC nodules at histology. For values between 36 and pg/mL, MTCs and nodular or micronodular C-cell hyperplasia (CCH) results overlapped. Most of the nodules without MTC and/or CCH had Ct-FNAB <17 pg/mL. Ct-FNAB diagnostic power was superior to and similar to other diagnostic procedures (Ct, Pg-sCt, and cytology) in identifying both MTC and CCH, and MTC alone, respectively.ConclusionThe diagnostic power of Ct-FNAB is valuable compared with other routine procedures. Ct-FNAB is highly reliable for the early detection and accurate localization of MTC in thyroid nodules, but it does not differentiate between MTC and CCH. Ct-FNAB is an extremely valuable diagnostic tool, especially considering that other diagnostic procedures do not provide a definitive diagnosis, and it can be included in the clinical work-up of thyroid nodules when MTC is suspected. (Endocr Pract. 2013;19:769-779)  相似文献   

14.
《Endocrine practice》2016,22(5):561-566
Objective: The time between the moment of referral for the diagnostic workup for thyroid nodules and the outcome can be worrisome for patients. In general, patients experience high levels of anxiety during the evaluation of a lesion suspicious for cancer. Therefore, the implementation of same-day fine-needle aspiration cytology (FNAC) diagnosis is becoming standard-of-care for many solid tumors. Our aim was to assess the feasibility of same-day FNAC diagnosis for thyroid nodules and to assess patient anxiety during the diagnostic process.Methods: For feasibility of same-day FNAC diagnosis, we assessed the proportion of patients receiving a diagnosis at the end of the visit. Accuracy was measured by comparing histology with the FNAC result. Patient anxiety was measured by the State Trait Anxiety Inventory at 6 moments during the diagnostic workup.Results: Of the 131 included patients, 112 (86%) were female, and the mean age was 53 years. All patients, except those with a nondiagnostic FNAC result (n = 26; 20%), had a diagnosis at the end of the day. There were only two discordant results. Anxiety levels at the beginning of the day were high throughout the group, State Trait Anxiety Inventory (STAI) score 43.1 (SD 2.0) and decreased significantly more in patients with a benign FNAC result (STAI score 30.2), compared to patients with a malignant or indeterminate result (STAI score 39.6).Conclusion: Distress of patients with a thyroid nodule undergoing same-day FNAC diagnostics was high. Same-day FNAC diagnosis is feasible and accurate for the evaluation of thyroid nodules. Therefore, same-day FNAC diagnosis seems a safer, more patient-friendly approach to diagnose thyroid nodules.Abbreviations:AUS = atypia of undetermined significanceCWS = Cancer Worry ScaleFNAC = fine-needle aspiration cytologySTAI = State Trait Anxiety InventoryTSH = thyroid-stimulating hormone  相似文献   

15.
《Endocrine practice》2004,10(4):311-316
ObjectiveTo evaluate whether analysis of thyroid hormones in fine-needle aspiration (FNA) of thyroid nodules can provide information about the functional status and the nature of the nodules.MethodsWe studied 4 groups of patients: group 1, 17 patients with autonomous hyperfunctioning thyroid nodules; group 2, 52 patients with cold nonfunctioning thyroid nodules; group 3, 12 patients with malignant thyroid nodules; and group 4 (control group), 10 patients with nonthyroid nodular lesions (enlarged parathyroid glands or lymph nodes). The assay of thyroid hormones was performed in FNA after the washing of needles and, with patient consent, also in normal thyroid parenchyma.ResultsThe free thyroxine (FT4) and free triiodothyronine (FT3) values were remarkably high in group 1 (mean, 5.5 ± 0.53 ng/dL and 27.6 ± 3.1 pg/mL, respectively; P < 0.05 versus group 2 and group 4, the control group). The levels of FT4 and FT3 were very low in group 3 (< 0.2 ng/dL and < 1.0 pg/mL, respectively; P < 0.05 versus group 2). Thyroglobulin values in FNA specimens were much higher than the normal range in human serum, but no significant differences were found between the various groups. The control group had low levels of FT4 and FT3 (< 0.2 ng/dL and < 1.0 pg/mL, respectively) in conjunction with low levels of thyroglobulin, whereas parathyroid hormone levels were high in parathyroid nodules.ConclusionThese results show that assay of FT4 and FT3 in FNA can yield information about the functional status of thyroid nodules and, indirectly, about the nature of nodules. In this era of sophisticated new molecular markers in FNA cytology, this low-cost diagnostic method can be readily performed in every laboratory. (Endocr Pract. 2004;10:311-316)  相似文献   

16.
Objective: To compare the outcomes and evaluate the relative risk of thyroid cancer by using the UK thyroid fine-needle aspiration (FNA) cytological diagnostic categories, with the main objective being the clarity of patient management. Study Design: Results of thyroid FNA reported as Thy3a, Thy3f, Thy4, and Thy5 were correlated with histological outcomes. The specificity and positive predictive value (PPV; risk of malignancy) for each reporting category was assessed. Results: Of a total of 873 thyroid FNAs, 237 (27%) were reported as 'abnormal': 40 (4.6%) as Thy3a, 119 (13.6%) as Thy3f, 20 (2.2%) as Thy4, and 58 (6.6%) as Thy 5. The final outcomes were available in 136 (57%) cases which underwent surgical resection (25, 60, 55, and 74% of Thy3a, Thy3f, Thy4, and Thy5, respectively). The known outcomes of the Thy3a category were too low to be statistically significant. The specificity and PPV of the Thy3f, Thy4, and Thy5 (equivalent to the Bethesda System for Reporting Thyroid Cytopathology (TBSRTC) IV, V, and VI) categories were 50, 50, and 100% and 28, 64, and 100%, respectively. The PPV of Thy3f for diagnosis of 'neoplasms' (benign and malignant) was 63%. Conclusion: The current thyroid FNA classification system used in the UK, which is comparable to TBSRTC, offers a sound basis for clear communication on which the management of patients with abnormal thyroid FNA findings can be based. Categories Thy3f, Thy4, and Thy5 carry a progressively rising risk of malignancy, justifying their continuing use. Diagnostic category Thy5 'malignant' is robust and can be used as a sure indication of a definitive surgical management.  相似文献   

17.
《Endocrine practice》2021,27(10):1011-1016
ObjectiveElectronic consultations (e-consults) are commonly used to obtain endocrinology input on clinical questions without a face-to-face visit, but sparse data exist on the resultant quality of care for specific conditions. We examined workups resulting in a thyroid nodule fine-needle aspiration (FNA) biopsy to investigate whether endocrinology e-consults were more timely and similarly guideline-concordant compared with endocrinology face-to-face visits and whether endocrinology e-consults were more guideline-concordant compared with workups without endocrinology input.MethodsWe retrospectively reviewed charts of 302 thyroid FNA biopsies conducted in the Veterans Affairs health system between May 1, 2017, and February 4, 2020 (e-consult, n = 99; face-to-face visit, n = 100; no endocrinology input, n = 103). We used t tests to compare timeliness, χ2 tests to compare the proportion of guideline-concordant workups, and multivariable linear and logistic models to control for demographic factors.ResultsFNAs preceded by an endocrinology e-consult had more timely workups compared with those preceded by endocrinology face-to-face visits in terms of days elapsed between referral and FNA biopsy (geometric mean 44.7 days vs 61.7 days, P = .01). The difference in the summary measure of guideline concordance across groups was not statistically significant (P =.38).ConclusionE-consults were faster than face-to-face consults and similarly guideline-concordant compared with both face-to-face consults and no endocrinology input for workups resulting in FNA. Decisions about the appropriate use of e-consults for thyroid nodules should take into account these data while also considering the potential benefits of direct patient-endocrinologist interaction for complex situations.  相似文献   

18.
目的:探讨超声引导下甲状腺穿刺活检(US-FNAB)对甲状腺良恶性结节的诊断价值。方法:本研究选取了60例已做过甲状腺结节手术的患者,入院后先行常规超声(US)检查后行超声引导下甲状腺穿刺活检(US-FNAB)通过观察并记录良恶性结节诊断结果:,诊断结果:符合率及诊断结果:符合率与结节大小的关系,评价US-FNAB对甲状腺良恶性结节的诊断价值。结果:常规超声诊断出恶性结节4例,良性结节33例;超声引导下细针穿刺活检诊断出恶性结节8例,良性结节40例。US组中,15例误诊,8例漏诊中,诊断符合率为61.7%。US-FNAB组中,4例误诊,漏诊2例,诊断符合率80.0%。经统计学分析,US-FNAB组诊断符合率明显高于US组(P0.05),US组与US-FNAB组在各结节直径的患者分布上相比差异无统计学意义(P0.05)。两组组内各结节直径的患者分布上相比差异也无统计学意义(P0.05)。US-FNAB组中,随着结节直径增大,诊断符合率略有降低。对直径10mm的甲状腺结节诊断率达100%。结论:US-FNBA对甲状腺良恶性结节具有较高的诊断准确性,诊断准确性受结节大小影响较小,对直径较小的甲状腺结节检出率较高。  相似文献   

19.
ObjectiveThyroid nodules are common, being detected in 19% to 67% of the population. A fine needle aspiration biopsy (FNAB) is recommended for suspicious thyroid nodules to rule out malignancy; however, the procedure can be painful for subsets of patients. It remains unclear what factors are more likely to be associated with pain during FNAB. This literature review aimed to investigate patient-, procedure-, and analgesic-related factors that affect pain levels during thyroid nodule FNAB.MethodsPredefined inclusion and exclusion criteria were set to search the Embase, MEDLINE, CINAHL, and Cochrane databases. The articles evaluating the factors affecting pain during FNAB were assessed for inclusion. The primary outcome of interest was scores evaluating pain level during FNAB.ResultsTwenty-two studies were included. The studies were a mix of cohort studies, randomized controlled trials, and clinical controlled trials. Under patient-related factor, nodule calcification was associated with increasing pain. The procedure-related factors potentially increasing pain included the number of needle passes and utilization of the aspiration technique (as opposed to capillary action), perpendicular needle placement (as opposed to parallel), and not using safety devices. Larger needle size, type of biopsy, operator expertise, and patient education did not appear to be correlated with pain. Subcutaneous lidocaine appeared to provide better pain relief than a topical analgesic.ConclusionWith increasing use of FNAB as the diagnostic test of choice for assessing thyroid nodules, understanding patient-, procedure-, and analgesic-related factors associated with optimal patient satisfaction is imperative.  相似文献   

20.
《Endocrine practice》2010,16(3):437-440
ObjectiveTo describe our experience with mediastinal parathyroid adenomas diagnosed by endoscopic ultrasound-guided fine-needle aspiration (EUSFNA) and measurement of parathyroid hormone.MethodsWe describe the clinical and pathologic findings and diagnostic techniques used in 2 study patients.ResultsPatient 1 was a 54-year-old man with persistently elevated serum calcium and parathyroid hormone concentrations despite removal of a right inferior parathyroid adenoma. An echoendoscope was used to identify the lesion and to perform FNA. The parathyroid hormone concentration measured in the aspirated material was 1800 pg/mL. Pathologic examination of the resected specimen revealed a 29.7-g parathyroid adenoma. Patient 2 was an 86-year-old woman with recurrent hyperparathyroidism. A linear array echoendoscope was used to perform FNA of the lesion in her mediastinum. The parathyroid hormone concentration measured in the aspirated specimen was 6905 pg/mL.ConclusionsPreoperative localization of recurrent or persistent hyperparathyroidism is often difficult. EUSFNA allows evaluation of masses, such as those found in the mediastinum, that are poorly evaluated by other imaging modalities. This technique may be a useful adjunct in diagnosing mediastinal parathyroid adenomas. (Endocr Pract. 2010;16:437-440)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号