首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 656 毫秒
1.
Headspace solid-phase microextraction (HS-SPME) was utilized for the determination of three dichlorobenzene isomers (DCBs) in human blood. In the headspace at 30°C, DCBs were absorbed for 15 min by a 100-μm polydimethylsiloxane (PDMS) fiber. They were then analyzed by capillary column gas chromatography–mass spectrometry (GC–MS). By setting the initial column oven temperature at 20°C, the three isomers were resolved at the baseline level. p-Xylene-d10 was used as the internal standard (I.S.). For quantitation, the molecular ion at m/z 146 for each isomer and the molecular ion at m/z 116 for I.S. were selected. For day-to-day precision, relative standard deviations in the range 3.2–10.7% were found at blood concentrations of 1.0 and 10 μg/ml. Each compound was detectable at a level of at least 0.02 μg per 1 g of whole blood (by full mass scanning). HS-SPME–GC–MS, when performed at relatively low temperatures, was found to be feasible in toxicological laboratories. Using this method, the plasma levels of one patient who had drunk a pesticide-like material were measured.  相似文献   

2.
3.
A simple, sensitive and specific liquid chromatography–electrospray tandem mass spectrometry (LC–MS–MS) method for the determination of clindamycin (I) was developed. Both I and verapamil (II, internal standard) were analyzed using a C18 column with a mobile phase of 80% acetonitrile–0.01% trifluoroacetic acid. Column eluents were monitored by electrospray tandem mass spectrometry. Multiple reaction monitoring (MRM) using the parent to daughter combinations of m/z 425→126 and 455→165 was used to quantitate I. A limit of quantitation of 0.0500 μg/ml was found. The assay exhibited a linear dynamic range of 0.0500–20.0 μg/ml and gave a correlation coefficient (r2) of 0.998 or better. The chromatographic run time was approximately 2 min. The intra-batch precision and accuracy of the quality controls (QCs, 0.0500, 0.150, 1.50, 15.0 and 20.0 μg/ml) were characterized by coefficients of variation (CVs) of 5.13 to 13.7% and relative errors (REs) of −4.34 to 4.58%, respectively. The inter-batch precision and accuracy of the QCs were characterized by CVs of 4.35 to 8.32% and REs of −10.8 to −4.17%, respectively. The method has successfully been applied to the analysis of samples taken up to 12 h after oral administration of 300 mg of I in healthy volunteers.  相似文献   

4.
A column-switching liquid chromatography–electrospray ionization-tandem mass spectrometric (LC–ESI-MS–MS) method was developed for the direct analysis of entacapone glucuronide in plasma. The plasma samples (5 μl) were injected onto a C18-alkyl-diol silica (ADS) column and the matrix compounds were washed to waste with a mixture of 20 mM ammonium acetate solution at pH 4.0–acetonitrile (97:3). The retained analyte fraction containing (E)- and (Z)-isomers of glucuronides of entacapone and tolcapone glucuronide (internal standard) was backflushed to the analytical C18 column, with a mixture of 20 mM ammonium acetate–acetonitrile (85:15) for the final separation at pH 7.0. The eluate was directed to the mass spectrometer after splitting (1:100). The mass spectrometer was operated in the negative ion mode and the deprotonated molecules [M−H] were chosen as precursor ions for the analytes and internal standard. Collisionally induced dissociation of [M−H] in MS–MS resulted in loss of the neutral glucuronide moiety and in the appearance of intensive negatively charged aglycones [M−H−Glu], which were chosen as the product ions for single reaction monitoring. Quantitative studies showed a wide dynamic range (0.0025–100 μg/ml) with correlation coefficients better than 0.995. The method was repeatable within-day (relative standard deviation, RSD<7%) and between-day (RSD<14%) and the recovery (78–103%) was better than with the traditional, laborious pretreatment method. The use of tandem mass spectrometry permitted low limits of detection (1 ng/ml of entacapone glucuronide). The method was applied for the quantitation of (E)- and (Z)-isomers of entacapone glucuronide in plasma of rats used in absorption studies.  相似文献   

5.
A new high-performance liquid chromatograhic procedure for simultaneous determination of pyrazinamide (PZA) and its three metabolites 5-hydroxypyrazinamide (5-OH-PZA), pyrazinoic acid (PA), and 5-hydroxypyrazinoic acid (5-OH-PA), in rat urine was developed. 5-OH-PZA and 5-OH-PA standards were obtained by enzymatic synthesis (xanthine oxidase) and checked by HPLC and GC–MS. Chromatographic separation was achieved in 0.01 M KH2PO4 (pH 5.2), circulating at 0.9 ml/min, on a C18 silica column, at 22°C. The limits of detection were 300 μg/l for PZA, 125 μg/l for PA, 90 μg/l for 5-OH-PZA and 70 μg/l for 5-OH-PA. Good linearity (r2>0.99) was observed within the calibration ranges studied: 0.375–7.50 mg/l for PZA, 0.416–3.33 mg/l for PA, 0.830–6.64 mg/l for 5-OH-PZA and 2.83–22.6 mg/l for 5-OHPA. Accuracy was always lower than ±10.8%. Precision was in the range 0.33–5.7%. The method will constitute a useful tool for studies on the influence of drug interactions in tuberculosis treatment.  相似文献   

6.
Infusion of norephinephrine (NE) (1 – 3 μg/ml/min) into the isolated mesenteric vascular preparation of rabbit resulted in a rise in perfusion pressure, which was associated with the release of a prostaglandin E-like substance (PGE) at a concentration of 2.81 ± 0.65 ng/ml in terms of PGE2. Indomethacin (3 μg/ml) abolished the NE-induced release of PGE. Arachidonic acid (0.2 μg/ml) in the presence of indomethacin did not restore the NE-induced release of PGE. Hydrocortisone (10 – 30 μg/ml) and dexamethasone (2 – 5 μg/ml) also inhibited the NE-induced release of PGE. The inhibitory action of both corticosteroids was abolished by arachidonic acid (0.2 μg/ml). Antigen-induced release of a prostaglandin-like substance(PGs) (43.1 ± 3.8 ng/ml in terms of PGE2 and a rabbit aorta contracting substance (RCS) from perfused lungs of sensitized guinea pigs was completely abolished by indomethacin (5 μg/ml) or by hydrocortisone (100 μg/ml). Indomethacin, however, increased histamine release up to 280% of the control level, which was 470 ± 54 ng/ml, while hydrocortisone diminished histamine release down to 30% of the control level. A superimposed infusion of arachidonic acid (1 μg/ml) into the pulmonary artery reversed the hydrocortisone-induced blockade of the release of RCS and PGs. It may be concluded that corticosteroids neither inhibit prostaglandin synthetase nor influence prostaglandin transport through the membranes but they do impair the availability of the substrate for the enzyme.  相似文献   

7.
Infusion of norephinephrine (NE) (1 – 3 μg/ml/min) into the isolated mesenteric vascular preparation of rabbit resulted in a rise in perfusion pressure, which was associated with the release of a prostaglandin E-like substance (PGE) at a concentration of 2.81 ± 0.65 ng/ml in terms of PGE2. Indomethacin (3 μg/ml) abolished the NE-induced release of PGE. Arachidonic acid (0.2 μg/ml) in the presence of indomethacin did not restore the NE-induced release of PGE. Hydrocortisone (10 – 30 μg/ml) and dexamethasone (2 – 5 μg/ml) also inhibited the NE-induced release of PGE. The inhibitory action of both corticosteroids was abolished by arachidonic acid (0.2 μg/ml). Antigen-induced release of a prostaglandin-like substance (PGs) (43.1 ± 3.8 ng/ml in terms of PGE2 and a rabbit aorta contracting substance (RCS) from perfused lungs of sensitized guinea pigs was completely abolished by indomethacin (5 μg/ml) or by hydrocortisone (100 μg/ml). Indomethacin, however, increased histamine release up to 280% of the control level, which was 470 ± 54 ng/ml, while hydrocortisone diminished histamine release down to 30% of the control level. A superimposed infusion of arachidonic acid (1 μg/ml) into the pulmonary artery reversed the hydrocortisone-induced blockade of the release of RCS and PGs. It may be concluded that corticosteroids neither inhibit prostaglandin synthetase nor influence prostaglandin transport through the membranes but they do impair the availability of the substrate for the enzyme.  相似文献   

8.
The stability of the experimental anti-tumour agent pancratistatin in human plasma has been investigated. A solid-phase extraction technique and an HPLC assay with external standards have been developed and validated. Extraction was performed using C18 cartridges and HPLC, analysis was performed on a 15 cm Hypersil BDS column using isocratic elution with 13% acetonitrile and aqueous solution of 1% (w/v) acetic acid. The lower limit of quantification for pancratistatin in 5% DMF–95% water was found to be 0.58 ng/ml (±10.58%) and 2.3 ng/ml (±9.2%) following extraction from human plasma. Mean recovery of 89.4% (±4.73%) was obtained over the concentration range 0.0023–9.45 μg/ml for a five day validation study. Pancratistatin was stable at room temperature in light or dark for at least 15 days, in the refrigerator at 4°C for at least 16 days and in the freezer at −20°C or −80°C for at least 28 days. Under all conditions monitored, % recovery of pancratistatin from human plasma was greater than 95% and no evidence of degradation had occurred. There also was no loss of pancratistatin after three cycles of freezing and thawing.  相似文献   

9.
Methionine enkephalin (ME = YGGFM) was measured in five individual human post-mortem pituitaries using four different analytical methods, with the objective of comparing the molecular specificities of the methods. Radioreceptor assay (RRA) used a receptor-rich preparation from brain and [3H]etorphine as radioligand to determine ME-like receptoractivity (ME-LR). Radioimmunoassay (RIA) measured ME-like immunoreactivity (ME-LI). Pituitary samples analyzed by RRA and RIA were purified first with a high-performance liquid chromatography (HPLC) gradient on a polymer analytical column. Fast atom bombardment mass spectrometry (FAB-MS) in two different detection modes quantified ME using the protonated molecular ion MH+ of ME at 574 a.m.u. and B/E linked-field selected reaction monitoring (SRM) to monitor the specific unimolecular metastable transition that produced the unique amino acid sequence-determining tetrapeptide fragment ion YGGF+ from the MH+ precursor ion. Both FAB-MS methods used the deuterated internal standard YGG[2H5-F]M. Samples analyzed with FAB-MS were purified first with multi-dimensional reversed-phase HPLC. The first dimension was an ODS gradient, and the second dimension was a polymer isocratic elution. The following ME amounts were measured (mean ± standard error of the mean): ME-LR, 7.0 ± 1.9 μg g−1 tissue; ME-LI, 1.8 ± 0.7 μg g−1 tissue; MH+, 2.7 ± 0.6 μg g−1 tissue; SRM, 3.0 ± 0.8 μg g−1 tissue. The FAB SRM method provided the highest level of molecular specificity amount these four analytical methods used to measure picomole amounts of endogenous ME in a human pituitary.  相似文献   

10.
A simple, highly selective and reproducible reversed-phase high-performance liquid chromatography method has been developed for the analysis of the new anti-cancer pro-drug AQ4N. The sample pre-treatment involves a simple protein precipitation protocol, using methanol. Chromatographic separations were performed using a HiChrom HIRPB (25 cm×4.6 mm I.D.) column, with mobile phase of acetonitrile–ammonium formate buffer (0.05 M) (22:78, v/v), with final pH adjusted to 3.6 with formic acid. The flow-rate was maintained at 1.2 ml min−1. Detection was via photodiode array performed in the UV range at 242 nm and, since the compounds are an intense blue colour, in the visible range at 612 nm. The structurally related compound mitoxantrone was used as internal standard. The validated quantification range of the method was 0.05–10.0 μg ml−1 in mouse plasma. The inter-day relative standard deviations (RSDs) (n=5) ranged from 18.4% and 12.1% at 0.05 μg ml−1 to 2.9% and 3.3% at 10.0 μg ml−1 for AQ4N and AQ4, respectively. The intra-day RSDs for supplemented mouse plasma (n=6) ranged from 8.2% and 14.2% at 0.05 μg ml−1 to 7.6% and 11.5% at 10.0 μg ml−1 for AQ4N and AQ4, respectively. The overall recovery of the procedure for AQ4N was 89.4±1.77% and 76.1±7.26% for AQ4. The limit of detection was 50 ng ml−1 with a 100 μl sample volume. The method described provides a suitable technique for the future analysis of low levels of AQ4N and AQ4 in clinical samples.  相似文献   

11.
A gas chromatographic–mass spectrometric method was developed for the quantitative analysis of the three Di(2-ethylhexyl)phthalate (DEHP) metabolites, 2-ethylhexanoic acid, 2-ethyl-3-hydroxyhexanoic acid and 2-ethyl-3-oxohexanoic acid in urine. After oximation with O-(2,3,4,5,6-pentafluorobenzyl)-hydroxylamine hydrochloride and sample clean-up with Chromosorb P filled glass tubes, all three organic acids were converted to their tert.-butyldimethylsilyl derivatives. Quantitation was done with trans-cinnamic acid as internal standard and GC–MS analysis in the selected ion monitoring mode (SIM). Calibration curves for all three acids in the range from 20 to 1000 μg/l showed correlation coefficients from 0.9972 to 0.9986. The relative standard deviation (RSD) values determined in the observed concentration range were between 1.3 and 8.9% for all three acids. Here we report for the first time the identification of 2-ethyl-3-hydroxyhexanoic acid and 2-ethyl-3-oxohexanoic acid in human urine next to the known DEHP metabolite 2-ethylhexanoic acid. In 28 urine samples from healthy persons we found all three acids with mean concentrations of 56.1±13.5 μg/l for 2-ethylhexanoic acid, 104.8± 80.6 μg/l for 2-ethyl-3-hydroxyhexanoic acid and 482.2± 389.5 μg/l for 2-ethyl-3-oxohexanoic acid.  相似文献   

12.
A method was developed for the determination of gemifloxacin (I) in human plasma using high-performance liquid chromatography–tandem mass spectrometry. Prior to analysis, the protein in plasma samples was precipitated with acetonitrile containing [13C2H3] gemifloxacin (II) to act as an internal standard. The supernatant was injected onto a PLRP-S column without any further clean-up. The mass spectrometer was operated in positive ion mode, employing a heat assisted nebulisation, electrospray interface. Ions were detected in multiple reaction monitoring (MRM) mode. The assay requires 50 μl of plasma and is precise and accurate within the range 10–5000 ng/ml. The average within-run and between-run coefficients of variation were <11% at 10 ng/ml and greater concentrations. The average accuracy of validation standards was generally within ±7% of the nominal concentration. There was no evidence of instability of I in human plasma following three complete freeze–thaw cycles and samples can safely be stored for at least 6 months at −20°C. The method proved very robust and was successfully applied to the analysis of clinical samples from patients dosed with gemifloxacin.  相似文献   

13.
High-temperature headspace solid-phase microextraction (SPME) with simultaneous (“in situ”) derivatisation (acetylation or silylation) is a new sample preparation technique for the screening of illicit drugs in urine and for the confirmation analysis in serum by GC–MS. After extraction of urine with a small portion of an organic solvent mixture (e.g., 2 ml of hexane–ethyl acetate) at pH 9, the organic layer is separated and evaporated to dryness in a small headspace vial. A SPME-fiber (e.g., polyacrylate) doped with acetic anhydride–pyridine (for acetylation) is exposed to the vapour phase for 10 min at 200°C in a blockheater. The SPME fiber is then injected into the GC–MS for thermal desorption and analysis. After addition of perchloric acid and extraction with n-hexane to remove lipids, the serum can be analysed after adjusting to pH 9 as described for urine. Very clean extracts are obtained. The various drugs investigated could be detected and identified in urine by the total ion current technique at the following concentrations: amphetamines (200 μg/l), barbiturates (500 μg/l), benzodiazepines (100 μg/l), benzoylecgonine (150 μg/l), methadone (100 μg/l) and opiates (200 μg/l). In serum all drugs could be detected by the selected ion monitoring technique within their therapeutic range. As compared to liquid–liquid extraction only small amounts of organic solvent are needed and larger amounts of the pertinent analytes could be transferred to the GC column. In contrast to solid-phase extraction (SPE), the SPME-fiber is reusable several times (as there is no contamination by endogenous compounds). The method is time-saving and can be mechanised by the use of a dedicated autosampler.  相似文献   

14.
A fast, robust and sensitive LC–MS–MS method for the determination of zearalenone (ZON) and its metabolites α-zearalenol (α-ZOL) and β-zearalenol (β-ZOL) in beer samples is described. Sample preparation was performed by direct RP-18 solid-phase extraction of undiluted beer samples followed by selective determination of analytes by LC–MS–MS applying an atmospheric pressure chemical ionization (APCI) interface. Using the negative ion mode limits of determination of 0.03–0.06 μg l−1 beer and limits of quantification of 0.07–0.15 μg l−1 beer were achieved, which was distinctly more sensitive than in the positive ion mode. Twenty-three beer samples from different countries, produced from different grains and under different brewing conditions, were investigated by this method, but only in one sample could β-ZOL and ZON be detected. Independently of the type of beer, relative standard deviations between 2.1% and 3.3%, a linear working range of 0.15 μg l−1 to 500 μg l−1 beer and recovery rates around 100% could be achieved when zearalanone (ZAN) was used as internal standard.  相似文献   

15.
A rapid HPLC method with solid-phase extraction (SPE) clean-up for malachite green (MG) and leucomalachite green (LMG) in eel plasma was developed. MG and LMG were extracted with a buffered methanolic solution. The extract was subjected to aromatic sulphonic acid SPE. MG and LMG were eluted from the SPE column with methanol after a treatment with ammonia gas. The reconstituted eluate was analyzed on a Chromspher B column with acetonitrile-ion-pair buffer (ph 4.0) (6:4, v/v) as the mobile phase and detection at 610 nm after post column oxidation with PbO2. The average recoveries for MG and LMG over the linear range of applicability (20–2500 ng/ml) were 82±1% and 83±1%, respectively. The limits of quantification were 5.0 μg/1 for MG and 0.9 μ/1 for LMG.  相似文献   

16.
Tamoxifen (TAM) is a triphenylethylene anti-oestrogen, commonly used in the treatment of breast cancer. Patients receiving tamoxifen therapy may experience both de novo and acquired resistance. As one of the mechanisms for this may be extensive peripheral bio-transformation of tamoxifen, there has been considerable interest in the pharmacokinetics and metabolism of tamoxifen. A reversed-phase high-performance liquid chromatography separation has been developed to determine the levels of tamoxifen and its major metabolites in human plasma. The method is highly sensitive (2 ng/ml) and selective for tamoxifen, cis-tamoxifen (CIS), 4-hydroxytamoxifen (4-OH) and desmethyltamoxifen (DMT). A μBondapak C18 10 μm column (30 cm × 3.9 mm I.D.) was used, with a mobile phase of methanol-1% triethylamine at pH 8 (89:11, v/v). Sample preparation was carried out using a C2 (500 mg sorbent, 3 ml reservoirs) solid phase extraction method, and extraction efficiencies were approximately 60% for TAM and its metabolites. Accuracy and precision, as determined by spiking plasma samples with a mixture of tamoxifen and its metabolites, ranged from 85–110% (± 5–10%) at 1 μg/ml, 101–118% (± 8–20%) at 0.1 μg/ml and 111–168% (± 43–63%) at 0.01 μg/ml. Results from 59 patients show mean values of 54 ng/ml for 4-OH; 190 ng/ml for DMT; 93 ng/ml for TAM and 30 ng/ml for CIS (detected in three patients only). This methodology can be applied routinely to the determination of TAM and its metabolites in plasma from patients undergoing therapy.  相似文献   

17.
We developed a sensitive and specific semi-automated liquid chromatography–electrospray mass spectrometric (HPLC–ESI-MS) assay for the simultaneous quantification of sirolimus and ciclosporin in blood. Following a simple protein precipitation step, the supernatants were injected into the HPLC system and extracted on-line. After column switching, the analytes were backflushed from the extraction column onto the analytical narrow-bore column and eluted into the ESI-MS system. The assay was linear from 0.4 to 100 μg/l sirolimus and from 2 to 1500 μg/l ciclosporin. The mean recoveries of sirolimus and ciclosporin were 98 and 96%, respectively. The mean interday precision/accuracy was 8.6%/−4.8% for sirolimus and 9.3%/−2.9% for ciclosporin.  相似文献   

18.
We have established an ultra-sensitive method for determination of ethanol in whole blood by headspace capillary gas chromatography (GC) with cryogenic oven trapping. After heating a blood sample containing ethanol and isobutyl alcohol (internal standard, IS) in a 7.0-ml vial at 55°C for 15 min, 5 ml of the headspace vapor was drawn into a glass syringe and injected into a GC port. All vapor was introduced into an Rtx-BAC2 wide-bore capillary column in the splitless mode at −60°C oven temperature to trap entire analytes, and then the oven temperature was programmed up to 240°C for GC measurements with flame ionization detection. The present method gave sharp peaks of ethanol and IS, and low background noise for whole blood samples. The mean partition into the gaseous phase for ethanol and IS was 3.06±0.733 and 8.33±2.19%, respectively. The calibration curves showed linearity in the range 0.02–5.0 μg/ml whole blood. The detection limit was estimated to be 0.01 μg/ml. The coefficients of intra-day and inter-day variation for spiked ethanol were 8.72 and 9.47%, respectively. Because of the extremely high sensitivity, we could measure low levels of endogenous ethanol in whole blood of subjects without drinking. The concentration of endogenous ethanol measured for 10 subjects under uncontrolled conditions varied from 0 to 0.377 μg/ml (mean, 0.180 μg/ml). Data on the diurnal changes of endogenous ethanol in whole blood of five subjects under strict food control are also presented; they are in accordance with the idea that endogenous blood ethanol is of enteric bacterial origin.  相似文献   

19.
A high-performance liquid chromatographic assay is described as a routine analytical method for the determination of flumequine (FLU) and its hydroxylated metabolite (OH-FLU) in pig kidney tissue. Kidney samples (2 g) containing FLU and OH-FLU were extracted by liquid-liquid extraction with ethyl acetate (10 ml). Analytical separations were performed by reversed-phase HPLC with fluorometric detection at 252 nm excitation and 356 nm emission under gradient conditions. The mobile phase was acetonitrile-2.7·10−3 M oxalic acid in water (pH 2.5). The assay is specific and reproducible within the flumequine range of 0.050–2.5 μg/g and recovery at 0.050 μg/g was 94.8%.  相似文献   

20.
A rapid, selective and sensitive HPLC assay has been developed for the routine analysis of metronidazole in small volumes of rat plasma, gastric aspirate and gastric tissue. The extraction procedure involves liquid–liquid extraction and a protein precipitation step. A microbore Hypersil ODS 3 μm (150×2.1 mm I.D.) column was used with a mobile phase consisting of acetonitrile–aqueous 0.05 M potassium phosphate buffer (pH 7) containing 0.1% triethylamine (10:90). The column temperature was at 25°C and the detection was by UV absorbance at 317 nm. The limit of detection was 0.015 μg ml−1 for gastric juice aspirate and plasma and 0.010 μg g−1 for gastric tissue (equivalent to 0.75 ng on-column). The method was linear up to a concentration of 200 μg ml−1 for plasma and gastric juice aspirate and up to 40 μg g−1 for tissue, with inter- and intra-day relative standard deviations less than 14%. The measured recovery was at least 78% in all sample matrices. The method proved robust and reliable when applied to the measurement of metronidazole in rat plasma, gastric juice aspirate and gastric tissue for pharmacokinetic studies in individual rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号