首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
The 1-MDS Virosorb filter and the 50S and 30S Zeta-plus filters, all with a net positive charge, were compared with the negatively charged Filterite filter for concentration of naturally occurring coliphages and animal viruses from sewage effluent. When Filterite filters were used, the effluent was adjusted to pH 3.5 and AlCl3 was added before filtration to facilitate virus adsorption. No adjustment was required with the positively charged filters. Sets of each filter type were eluted with 3% beef extract (pH 9.5) or eluted with 0.05 M glycine (pH 11.5). A maximum volume of 19 liters could be passed through 142-mm diameter Filterite filters before clogging, whereas only 11, 11, and 15 liters could be passed through the 1-MDS, 50S, and 30S filters, respectively. For equal volumes passed through the filters, coliphage recoveries were 14, 15, 18, and 37% in primary effluent and 40, 97, 50, and 46% in secondary effluent for the Filterite , 1-MDS, 50S, and 30S filters, respectively. No statistically significant difference was observed in the recovery of animal viruses among the filters from secondary effluent, whereas in the Filterite and 50S filters, higher numbers of viruses from primary effluent were recovered than in the 1-MDS and 30S filters in two of three collections. Glycine was found to be a less-efficient eluent than beef extract in the recovery of naturally occurring viruses.  相似文献   

2.
Positively charged Zeta Plus filters were used to concentrate enteroviruses from 19 liters of effluent from activated sludge units. Neither the addition of salts nor the acidification of the effluent was required for adsorption of viruses to the filters. Viruses adsorbed to the filters were eluted by treating the filters with a solution of 4 M urea buffered at pH 9 with 0.05 M lysine. Eluted viruses were concentrated into final volumes of 1 to 2 ml by using a two-step concentration procedure that employed inorganic and organic flocculation. Approximately 50% of the viruses added to effluents could be recovered in the final sample. The procedure was used to monitor effluents from activated sludge units at two wastewater treatment plants for the presence of enteroviruses.  相似文献   

3.
Simple, reliable, and efficient concentration of poliovirus from tap water was obtained with two types of electropositive filter media, one of which is available in the form of a pleated cartridge filter (Virozorb 1MDS). Virus adsorption from tap water between pH 3.5 and 7.5 was more efficient with electropositive filters than with Filterite filters. Elution of adsorbed viruses was more efficient with beef extract in glycine, pH 9.5, than with glycine-NaOH, pH 11.0. In paired comparative studies, electropositive filters, with adsorption at pH 7.5 and no added polyvalent cation salts, gave less variable virus concentration efficiencies than did Filterite filters with adsorption at pH 3.5 plus added MgCl2. Recovery of poliovirus from 1,000-liter tap water volumes was approximately 30% efficient with both Virozorb 1MDS and Filterite pleated cartridge filters, but the former were much simpler to use. The virus adsorption behavior of these filters appears to be related to their surface charge properties, with more electropositive filters giving more efficient virus adsorption from tap water at higher pH levels.  相似文献   

4.
Poliovirus concentration from tap water with electropositive adsorbent filters   总被引:10,自引:0,他引:10  
Simple, reliable, and efficient concentration of poliovirus from tap water was obtained with two types of electropositive filter media, one of which is available in the form of a pleated cartridge filter (Virozorb 1MDS). Virus adsorption from tap water between pH 3.5 and 7.5 was more efficient with electropositive filters than with Filterite filters. Elution of adsorbed viruses was more efficient with beef extract in glycine, pH 9.5, than with glycine-NaOH, pH 11.0. In paired comparative studies, electropositive filters, with adsorption at pH 7.5 and no added polyvalent cation salts, gave less variable virus concentration efficiencies than did Filterite filters with adsorption at pH 3.5 plus added MgCl2. Recovery of poliovirus from 1,000-liter tap water volumes was approximately 30% efficient with both Virozorb 1MDS and Filterite pleated cartridge filters, but the former were much simpler to use. The virus adsorption behavior of these filters appears to be related to their surface charge properties, with more electropositive filters giving more efficient virus adsorption from tap water at higher pH levels.  相似文献   

5.
By using recently developed cultivation and assay systems, currently available methods for concentrating enteric viruses from drinking water by adsorption to and subsequent elution from microporous filters followed by organic flocculation were evaluated for their ability to recover hepatitis A virus (HAV). Cell culture-adapted HAV (strain HM-175) in seeded tapwater was efficiently adsorbed by both electronegative (Filterite) and electropositive (Virosorb 1MDS) filters at pH and ionic conditions previously used for other enteric viruses. Adsorbed HAV was efficiently eluted from these filters by beef extract eluents at pH 9.5. Eluted HAV was further concentrated efficiently by acid precipitation (organic flocculation) of eluents containing beef extract made from powdered, but not paste, sources. By using optimum adsorption conditions for each type of filter, HAV was concentrated greater than 100-fold from samples of seeded tapwater, with about 50% recovery of the initial infectious virus added to the samples. The ability to recover and quantify HAV in contaminated drinking water with currently available methods should prove useful in further studies to determine the role of drinking water in HAV transmission.  相似文献   

6.
By using recently developed cultivation and assay systems, currently available methods for concentrating enteric viruses from drinking water by adsorption to and subsequent elution from microporous filters followed by organic flocculation were evaluated for their ability to recover hepatitis A virus (HAV). Cell culture-adapted HAV (strain HM-175) in seeded tapwater was efficiently adsorbed by both electronegative (Filterite) and electropositive (Virosorb 1MDS) filters at pH and ionic conditions previously used for other enteric viruses. Adsorbed HAV was efficiently eluted from these filters by beef extract eluents at pH 9.5. Eluted HAV was further concentrated efficiently by acid precipitation (organic flocculation) of eluents containing beef extract made from powdered, but not paste, sources. By using optimum adsorption conditions for each type of filter, HAV was concentrated greater than 100-fold from samples of seeded tapwater, with about 50% recovery of the initial infectious virus added to the samples. The ability to recover and quantify HAV in contaminated drinking water with currently available methods should prove useful in further studies to determine the role of drinking water in HAV transmission.  相似文献   

7.
Membrane adsorption-elution techniques have made it possible to concentrate and detect small numbers of viruses in large volumes of water and wastewater, but no such methods are available for quantitative recovery of bacteria. A number of waterborne disease outbreaks of "unknown etiology" in the United States are suspected to have been caused by pathogens present in numbers too small to be detected by currently available methodology. The present study reports on the use of positively charged depth filters for the concentration and detection of bacteria in large volumes of tap water. In this method, dechlorinated tap water was passed, under positive pressure, through positively charged filter media (Zetaplus, 05S). More than 90% of seeded bacteria adsorbed to these filters at ambient pH levels. Adsorbed bacteria were eluted by passing a small volume of Trypticase soy broth in the direction opposite of the influent flow. By this method, Escherichia coli and Salmonella serovar B organisms in 20 liters of tap water were concentrated in a final volume of 50 ml, with an average recovery efficiency of greater than or equal to 30%.  相似文献   

8.
Electronegative microporous filters composed of epoxyfiberglass (Filterite) were treated with cationic polymers to enhance their virus-adsorbing properties. This novel and inexpensive approach to microporous filter modification entails soaking filters in an aqueous solution of a cationic polymer such as polyethyleneimine (PEI) for 2 h at room temperature and then allowing the filters to air dry overnight on absorbent paper towels. PEI-treated filters were evaluated for coliphage (MS2, T2, and phi X174) and enterovirus (poliovirus type 1 and coxsackievirus type B5) adsorption from buffer at pH 3.5 to 9.0 and for indigenous coliphages from unchlorinated secondary effluent at ambient pH. Adsorbed viruses were recovered with 3% beef extract (pH 9). Several other cationic polymers were used to modify epoxyfiberglass filters and were evaluated for their ability to concentrate viruses from water. Zeta potentials of disrupted filter material indicated that electronegative epoxyfiberglass filters were made more electropositive when treated with cationic polymers. In general, epoxyfiberglass filters treated with cationic polymers were found to adsorb a greater percentage of coliphages and enteroviruses than were untreated filters.  相似文献   

9.
Electronegative microporous filters composed of epoxyfiberglass (Filterite) were treated with cationic polymers to enhance their virus-adsorbing properties. This novel and inexpensive approach to microporous filter modification entails soaking filters in an aqueous solution of a cationic polymer such as polyethyleneimine (PEI) for 2 h at room temperature and then allowing the filters to air dry overnight on absorbent paper towels. PEI-treated filters were evaluated for coliphage (MS2, T2, and phi X174) and enterovirus (poliovirus type 1 and coxsackievirus type B5) adsorption from buffer at pH 3.5 to 9.0 and for indigenous coliphages from unchlorinated secondary effluent at ambient pH. Adsorbed viruses were recovered with 3% beef extract (pH 9). Several other cationic polymers were used to modify epoxyfiberglass filters and were evaluated for their ability to concentrate viruses from water. Zeta potentials of disrupted filter material indicated that electronegative epoxyfiberglass filters were made more electropositive when treated with cationic polymers. In general, epoxyfiberglass filters treated with cationic polymers were found to adsorb a greater percentage of coliphages and enteroviruses than were untreated filters.  相似文献   

10.
Because naturally occurring organic matter is thought to interfere with virus adsorption to microporous filters, humic and fulvic acids isolated from a highly colored, soft surface water were used as model organics in studies on poliovirus adsorption to and recovery from electropositive Virosorb 1MDS and electronegative Filterite filters. Solutions of activated carbon-treated tap water containing 3, 10, and 30-mg/liter concentrations of humic or fulvic acid were seeded with known amounts of poliovirus and processed with Virosorb 1MDS filters at pH 7.5 or Filterite filters at pH 3.5 (with and without 5 mM MgCl2). Organic acids caused appreciable reductions in virus adsorption and recovery efficiencies with both types of filter. Fulvic acid caused greater reductions in poliovirus recovery with Virosorb 1MDS filters than with Filterite filters. Fulvic acid interference with poliovirus recovery by Filterite filters was overcome by the presence of 5 mM MgCl2. Although humic acid reduced poliovirus recoveries by both types of filter, its greatest effect was on virus elution and recovery from Filterite filters. Single-particle analyses demonstrated MgCl2 enhancement of poliovirus association with both organic acids at pH 3.5. The mechanisms by which each organic acid reduced virus adsorption and recovery appeared to be different for each type of filter.  相似文献   

11.
Because naturally occurring organic matter is thought to interfere with virus adsorption to microporous filters, humic and fulvic acids isolated from a highly colored, soft surface water were used as model organics in studies on poliovirus adsorption to and recovery from electropositive Virosorb 1MDS and electronegative Filterite filters. Solutions of activated carbon-treated tap water containing 3, 10, and 30-mg/liter concentrations of humic or fulvic acid were seeded with known amounts of poliovirus and processed with Virosorb 1MDS filters at pH 7.5 or Filterite filters at pH 3.5 (with and without 5 mM MgCl2). Organic acids caused appreciable reductions in virus adsorption and recovery efficiencies with both types of filter. Fulvic acid caused greater reductions in poliovirus recovery with Virosorb 1MDS filters than with Filterite filters. Fulvic acid interference with poliovirus recovery by Filterite filters was overcome by the presence of 5 mM MgCl2. Although humic acid reduced poliovirus recoveries by both types of filter, its greatest effect was on virus elution and recovery from Filterite filters. Single-particle analyses demonstrated MgCl2 enhancement of poliovirus association with both organic acids at pH 3.5. The mechanisms by which each organic acid reduced virus adsorption and recovery appeared to be different for each type of filter.  相似文献   

12.
The efficiency of a system developed for the recovery of viruses contaminating large quantities of vegetables was investigated in the laboratory and tested in the field. Viruses seeded onto a number of leafy vegetables in the laboratory were eluted with a phosphate-buffered saline solution (pH 9.0). The eluate was clarified by glass wool filtration, and any viruses present were concentrated by adsorption to a Filterite pleated cartridge filter, eluted with 3% beef extract (pH 9.0), and further concentrated by organic flocculation. At least 24 liters of vegetable eluate could be concentrated to 70 to 80 ml, equivalent to a greater than 99.5% reduction in volume. With this system, poliovirus was recovered with a mean efficiency of 58% for all vegetables tested. Adenovirus was recovered from lettuce with a slightly lower mean efficiency (55%). Poliovirus was recovered from large quantities of cabbage for up to 5 days in the field after spray irrigation of relatively low levels of virus, even when heavy rain fell before sampling.  相似文献   

13.
The efficiency of a system developed for the recovery of viruses contaminating large quantities of vegetables was investigated in the laboratory and tested in the field. Viruses seeded onto a number of leafy vegetables in the laboratory were eluted with a phosphate-buffered saline solution (pH 9.0). The eluate was clarified by glass wool filtration, and any viruses present were concentrated by adsorption to a Filterite pleated cartridge filter, eluted with 3% beef extract (pH 9.0), and further concentrated by organic flocculation. At least 24 liters of vegetable eluate could be concentrated to 70 to 80 ml, equivalent to a greater than 99.5% reduction in volume. With this system, poliovirus was recovered with a mean efficiency of 58% for all vegetables tested. Adenovirus was recovered from lettuce with a slightly lower mean efficiency (55%). Poliovirus was recovered from large quantities of cabbage for up to 5 days in the field after spray irrigation of relatively low levels of virus, even when heavy rain fell before sampling.  相似文献   

14.
Four enteric viruses, poliovirus type 1, echovirus type 1, reovirus type 3, and simian adenovirus SV-11, were concentrated from seeded 1.3-liter volumes of raw, finished, and granular activated carbon-treated waters by adsorption to 47-mm-diameter (17 cm2), electropositive ( Virosorb 1MDS ) filters at pH 7.5 or electronegative ( Filterite ) filters at pH 3.5 with and without 5 mM added MgCl2, followed by elution with 0.3% beef extract in 50 mM glycine at pH 9.5. Removal of particulates from raw and finished waters by 0.2-micron prefiltration before virus addition and pH adjustment had little effect on virus concentration efficiencies. Soluble organic compounds reduced virus adsorption efficiencies from both raw and finished waters compared with granular activated carbon-treated water, but the extent of interference varied with virus type and adsorption conditions. For electropositive 1MDS filters, organic interference was similar with all virus types. For Filterite filters, organic interference was evident with poliovirus and echovirus, but could be overcome by adding MgCl2. Reovirus and SV-11 were not adversely affected by organics during adsorption to Filterite filters. Elution of reovirus and adenovirus was inefficient compared with that of poliovirus and echovirus. None of the three adsorption schemes ( 1MDS at pH 7.5 and Filterite with and without 5 mM MgCl2 at pH 3.5) could be judged superior for all viruses and water types tested.  相似文献   

15.
A simple method with poliovirus as the model was developed for recovering human enteric viruses from aerosols. Filterite filters (pore size, 0.45 micron; Filterite Corp., Timonium, Md.) moistened with glycine buffer (pH 3.5) were used for adsorbing the aerosolized virus. No virus passed the filter, even with air flow rates of 100 liters/min. Virus recovery from the filter was achieved by rapid elution with 800 ml of glycine buffer, pH 10. The virus in the primary eluate was reconcentrated by adjusting the pH to 3.5, adding AlCl3 to 0.0005 M, collecting the virus on a 0.25-micron-pore Filerite disk (diameter, 25 mm) and and eluting with 6 ml of buffer, pH 10. With this method, virus could be detected regularly in aerosols produced by flushing when 3 X 10(8) PFU of poliovirus were present in the toilet bowl. Poliovirus-containing fecal material from two of four infants who had recently received oral polio vaccine also yielded virus in the aerosols when feces containing 2.4 X 10(7) to 4.5 X 10(7) PFU of virus had been added to the toilet bowl. Persons infected with a variety of natural enteric viruses are known to excrete this amount of virus in their daily stools.  相似文献   

16.
Method for detecting viruses in aerosols.   总被引:2,自引:1,他引:1       下载免费PDF全文
A simple method with poliovirus as the model was developed for recovering human enteric viruses from aerosols. Filterite filters (pore size, 0.45 micron; Filterite Corp., Timonium, Md.) moistened with glycine buffer (pH 3.5) were used for adsorbing the aerosolized virus. No virus passed the filter, even with air flow rates of 100 liters/min. Virus recovery from the filter was achieved by rapid elution with 800 ml of glycine buffer, pH 10. The virus in the primary eluate was reconcentrated by adjusting the pH to 3.5, adding AlCl3 to 0.0005 M, collecting the virus on a 0.25-micron-pore Filerite disk (diameter, 25 mm) and and eluting with 6 ml of buffer, pH 10. With this method, virus could be detected regularly in aerosols produced by flushing when 3 X 10(8) PFU of poliovirus were present in the toilet bowl. Poliovirus-containing fecal material from two of four infants who had recently received oral polio vaccine also yielded virus in the aerosols when feces containing 2.4 X 10(7) to 4.5 X 10(7) PFU of virus had been added to the toilet bowl. Persons infected with a variety of natural enteric viruses are known to excrete this amount of virus in their daily stools.  相似文献   

17.
Membrane filter adsorption-elution technology has been extensively used for the concentration and detection of animal viruses from large volumes of water. This study describes the development of positively charged microporous filters (Zeta Plus) for the concentration of coliphages from large volumes of water and wastewater. Four different coliphages were studied: MS-2, phi X174, T2, and T4. Positively charged microporous filters were found to efficiently adsorb these coliphages from tap water, sewage, and lake water at neutral pH. Adsorbed viruses were eluted with a 1:1 mixture of 8% beef extract and 1 M sodium chloride at pH 9. Using this method, coliphages could be concentrated from 17-liter volumes of tap water with recoveries ranging from 34 to 100%. Coliphages occurring naturally in raw and secondarily treated sewage were recovered with average efficiencies of 56.5 and 55.0%, respectively. This method should be useful in isolation of rare phages, the ecology of phages in natural waters, and the evaluation of water quality.  相似文献   

18.
Human viral contamination in drinking and recreational water may persist for extensive periods of time and cause a significant health risk concern. The aim of this study is to evaluate a viral recovery method using a new electropositive charged nanoalumina filter and to compare results with the widely used negatively charged HAWP filter by Millipore Inc. The recovery of infectious recombinant adenovirus type 5 (rAd5) was tested using the Fluorescence-Activated Cell Sorting (FACS) assay, in parallel with viral genomes recovery assay by quantitative PCR (qPCR). The mean infectivity recoveries were 82-91% by nanoalumina filters eluted with 3% beef extract (BE, pH6.0), and 78-90% by HAWP filters eluted with 3% BE (pH 9.0), respectively, from 1 L of environmental samples seeded with 1pfu/mL rAd5. The mean genome recoveries were 16-35% by nanoalumina filters eluted with BE (pH 6.0), and 29-66% by HAWP filters eluted with NaOH (pH 10.8) from different types of water, respectively. Water quality, concentration of viruses, filters, and elution buffers are factors that determine the viral recovery efficiencies. The nanoalumina filters also had higher filtration rates than HAWP filters for large volumes of environmental water samples (up to10 L), thus, have an advantage in concentrating infectious viruses from environments without pre-filtration, adjusting pH or adding multivalent cations.  相似文献   

19.
Four enteric viruses, poliovirus type 1, echovirus type 1, reovirus type 3, and simian adenovirus SV-11, were concentrated from seeded 1.3-liter volumes of raw, finished, and granular activated carbon-treated waters by adsorption to 47-mm-diameter (17 cm2), electropositive ( Virosorb 1MDS ) filters at pH 7.5 or electronegative ( Filterite ) filters at pH 3.5 with and without 5 mM added MgCl2, followed by elution with 0.3% beef extract in 50 mM glycine at pH 9.5. Removal of particulates from raw and finished waters by 0.2-micron prefiltration before virus addition and pH adjustment had little effect on virus concentration efficiencies. Soluble organic compounds reduced virus adsorption efficiencies from both raw and finished waters compared with granular activated carbon-treated water, but the extent of interference varied with virus type and adsorption conditions. For electropositive 1MDS filters, organic interference was similar with all virus types. For Filterite filters, organic interference was evident with poliovirus and echovirus, but could be overcome by adding MgCl2. Reovirus and SV-11 were not adversely affected by organics during adsorption to Filterite filters. Elution of reovirus and adenovirus was inefficient compared with that of poliovirus and echovirus. None of the three adsorption schemes ( 1MDS at pH 7.5 and Filterite with and without 5 mM MgCl2 at pH 3.5) could be judged superior for all viruses and water types tested.  相似文献   

20.
Microporous filters that are more electropositive than the negatively charged filters currently used for virus concentrations from water by filter adsorption-elution methods were evaluated for poliovirus recovery from tap water. Zeta Plus filters composed of diatomaceous earth-cellulose-"charge-modified" resin mixtures and having a net positive charge of up to pH 5 to 6 efficiently adsorbed poliovirus from tap water at ambient pH levels 7.0 to 7.5 without added multivalent cation salts. The adsorbed virus were eluted with glycine-NaOH, pH 9.5 to 11.5. Electropositive asbestos-cellulose filters efficiently adsorbed poliovirus from tap water without added multivalent cation salts between pH 3.5 and 9.0, and the absorbed viruses could be eluted with 3% beef extract, pH 9, but not with pH 9.5 to 11.5 glycine-NaOH. Under water quality conditions in which poliovirus recoveries from large volumes of water were less than 5% with conventional negatively charged filters and standard methods, recoveries with Zeta Plus filters averaged 64 and 22.5% for one- and two-stage concentration procedures, respectively. Electropositive filters appear to offer distinct advantages over conventional negatively charged filters for concentrating enteric viruses from water, and their behavior tends to confirm the importance of electrostatic forces in virus recovery from water by microporous filter adsorption-elution methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号