首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Molecular beacons represent a new family of fluorescent probes for nucleic acids, and have found broad applications in recent years due to their unique advantages over traditional probes. Detection of nucleic acids using molecular beacons has been based on hybridization between target molecules and molecular beacons in a 1:1 stoichiometric ratio. The stoichiometric hybridization, however, puts an intrinsic limitation on detection sensitivity, because one target molecule converts only one beacon molecule to its fluorescent form. To increase the detection sensitivity, a conventional strategy has been target amplification through polymerase chain reaction. Instead of target amplification, here we introduce a scheme of signal amplification, nicking enzyme signal amplification, to increase the detection sensitivity of molecular beacons. The mechanism of the signal amplification lies in target-dependent cleavage of molecular beacons by a DNA nicking enzyme, through which one target DNA can open many beacon molecules, giving rise to amplification of fluorescent signal. Our results indicate that one target DNA leads to cleavage of hundreds of beacon molecules, increasing detection sensitivity by nearly three orders of magnitude. We designed two versions of signal amplification. The basic version, though simple, requires that nicking enzyme recognition sequence be present in the target DNA. The extended version allows detection of target of any sequence by incorporating rolling circle amplification. Moreover, the extended version provides one additional level of signal amplification, bringing the detection limit down to tens of femtomolar, nearly five orders of magnitude lower than that of conventional hybridization assay.  相似文献   

2.
Molecular beacons are oligonucleotide probes capable of forming a stem-loop hairpin structure with a reporter dye at one end and a quencher at the other end. Conventional molecular beacons are designed with a target-binding domain flanked by two complementary short arm sequences that are independent of the target sequence. Here we report the design of shared-stem molecular beacons with one arm participating in both stem formation when the beacon is closed and target hybridization when it is open. We performed a systematic study to compare the behavior of conventional and shared-stem molecular beacons by conducting thermodynamic and kinetic analyses. Shared-stem molecular beacons form more stable duplexes with target molecules than conventional molecular beacons; however, conventional molecular beacons may discriminate between targets with a higher specificity. For both conventional and shared-stem molecular beacons, increasing stem length enhanced the ability to differentiate between wild-type and mutant targets over a wider range of temperatures. Interestingly, probe-target hybridization kinetics were similar for both classes of molecular beacons and were influenced primarily by the length and sequence of the stem. These findings should enable better design of molecular beacons for various applications.  相似文献   

3.
A powerful combination of molecular beacon and luminescence resonance energy transfer technology reveals alterations in nucleic acid structure by as little as a single nucleotide in a novel hybridization proximity assay. The assay measures the length of a single-stranded target when a terbium chelate-labeled molecular beacon hybridizes to one side of the nucleic acid segment to be measured and an acceptor probe carrying a convention fluorophore hybridizes to the opposite end of the target. Using a test sequence shortened incrementally by deleting single nucleotides, this assay reports a nearly linear relationship between sequence length and the distance separating acceptor and donor probes. Consequently, this assay can be used to detect alternative splicing, allele types, rearrangements, insertion, and deletion events by measuring separation distances within a predefined region. Furthermore, the use of terbium chelates in molecular beacons can produce exceptionally high signal-to-background ratios compared to the use of conventional fluorophores. Principles of optimal probe design are investigated experimentally and by computational simulations of plausible molecular beacon folding. Some molecular beacon designs form dimers that reduce their maximal response to target sequences. A simple assay to detect such dimers is reported as a tool to help improve the design of molecular beacons. Optimally designed molecular beacons with terbium chelates and hybridization proximity assays are expected to expand their applications in the analysis and screening of genetic diseases.  相似文献   

4.
PNA beacons for duplex DNA   总被引:12,自引:0,他引:12  
We report here on the hybridization of peptide nucleic acid (PNA)-based molecular beacons (MB) directly to duplex DNA sites locally exposed by PNA openers. Two stemless PNA beacons were tested, both featuring the same recognition sequence and fluorophore-quencher pair (Fluorescein and DABCYL, respectively) but differing in arrangement of these groups and net electrostatic charge. It was found that one PNA beacon rapidly hybridized, with the aid of openers, to its complementary target within duplex DNA at ambient conditions via formation of a PD-like loop. In contrast, the other PNA beacon bound more slowly to preopened duplex DNA target and only at elevated temperatures, although it readily hybridized to single-stranded (ss) DNA target. Besides a higher selectivity of hybridization provided by site-specific PNA openers, we expect this approach to be very useful in those MB applications when denaturation of the duplex DNA analytes is unfavorable or undesirable. Furthermore, we show that PNA beacons are advantageous over DNA beacons for analyzing unpurified/nondeproteinized DNA samples. This feature of PNA beacons and our innovative hybridization strategy may find applications in emerging fluorescent DNA diagnostics.  相似文献   

5.
Molecular beacon technology is set up based on fluorescence resonance energy transfer (FRET) and the complementary pairing principles. These fluorescent molecular probes, which are very highly specific and sensitive, have now become one important tool in medical and biological researches. This review introduces the molecular beacons structure, principle, the main impact factors, the labeling of the molecular beacons, and research progress on molecular beacons fluorescent-label in the polymerase chain reaction (PCR), DNA sequence analysis, gene dynamic detection in living cells, protein (enzyme)-nucleic acid interactions and applications in clinical medicine.  相似文献   

6.
Belon CA  Frick DN 《BioTechniques》2008,45(4):433-40, 442
A high-throughput, fluorescence-based helicase assay using molecular beacons is described. The assay is tested using the NS3 helicase encoded by the hepatitis C virus (HCV) and is shown to accurately monitor helicase action on both DNA and RNA. In the assay, a ssDNA oligonucleotide molecular beacon, featuring a fluorescent moiety attached to one end and a quencher attached to the other, is annealed to a second longer DNA or RNA oligonucleotide. Upon strand separation by a helicase and ATP, the beacon strand forms an intramolecular hairpin that brings the tethered fluorescent and quencher molecules into juxtaposition, quenching fluorescence. Unlike currently available real-time helicase assays, the molecular beacon-based helicase assay is irreversible. As such, it does not require the addition of extra DNA strands to prevent products from re-annealing. Several variants of the new assay are described and experimentally verified using both Cy3 and Cy5 beacons, including one based on a sequence from the HCV genome. The HCV genome-based molecular beacon helicase assay is used to demonstrate how such an assay can be used in high-throughput screens and to analyze HCV helicase inhibitors.  相似文献   

7.
A DNA hybridization based optical detection platform for the detection of foodborne pathogens has been developed with virtually zero probability of the false negative signal. This portable, low-cost and real-time assaying detection platform utilizes the color changing molecular beacon as a probe for the optical detection of the target sequence. The computer-controlled detection platform exploits the target hybridization induced change of fluorescence color due to the F?rster (fluorescence) resonance energy transfer (FRET) between a pair of spectrally shifted fluorophores conjugated to the opposite ends of a beacon (oligonucleotide probe). Unlike the traditional fluorophore-quencher beacon design, the presence of two fluorescence molecules allows to actively visualize both hybridized and unhybridized states of the beacon. This eliminates false negative signal detection characteristic for the fluorophore-quencher beacon where bleaching of the fluorophore or washout of a beacon is indistinguishable from the absence of the target DNA sequence. In perspective, the two-color design allows also to quantify the concentration of the target DNA in a sample down to < =1 ng/microl. The new design is suitable for simultaneous reliable detection of hundreds of DNA target sequences in one test run using a series of beacons immobilized on a single substrate in a spatial format.  相似文献   

8.
9.
We demonstrate that single-nucleotide differences in a DNA sequence can be detected in homogeneous assays using molecular beacons. In this method, the region surrounding the site of a sequence variation is amplified in a polymerase chain reaction and the identity of the variant nucleotide is determined by observing which of four differently colored molecular beacons binds to the amplification product. Each of the molecular beacons is perfectly complementary to one variant of the target sequence and each is labeled with a different fluorophore. To demonstrate the specificity of these assays, we prepared four template DNAs that only differed from one another by the identity of the nucleotide at one position. Four amplification reactions were prepared, each containing all four molecular beacons, but each initiated with only one of the four template DNAs. The results show that in each reaction a fluorogenic response was elicited from the molecular beacon that was perfectly complementary to the amplified DNA, but not from the three molecular beacons whose probe sequence mismatched the target sequence. The color of the fluorescence that appeared in each tube during the course of the amplification indicated which nucleotide was present at the site of variation. These results demonstrate the extraordinary specificity of molecular beacons. Furthermore, the results illustrate how the ability to label molecular beacons with differently colored fluorophores enables simple multiplex assays to be carried out for genetic analysis.  相似文献   

10.
A molecular beacon (MB) array was designed based on unique regions of the 16S rRNA of the bacterium Francisella tularensis. Nucleic acid molecular beacons undergo a spontaneous fluorogenic conformational change when they hybridize to specific complementary targets. The array was printed on aldehyde glass or hydrogel slides and evaluated for functioning in presence of complementary oligonucleotide sequences, single-nucleotide mismatch sequences and multiple nucleotide mismatch sequences. Discriminating true target from mismatched targets was found to be dependent on type, number, and location of mismatches within the beacon (i.e. located in the stem or loop regions). Optimal conditions for molecular beacon deposition, and target hybridization were determined for oligonucleotide target mismatch discrimination. The beacon array was stable upon recharging by exposure to an alkaline solution, and repeatedly used. In addition, performance of the beacon array biosensor was compared with molecular beacons in homogeneous solution.  相似文献   

11.
Nitin N  Bao G 《Bioconjugate chemistry》2008,19(11):2205-2211
Imaging the expression and localization of RNAs in live-cell nucleus can provide important information on RNA synthesis, processing, and transport. Here, we report the development of a bifunctional molecular beacon (NLS-MB) composed of a single nuclear localization sequence (NLS) peptide conjugated to a molecular beacon for efficient delivery and imaging of endogenous RNAs in the nuclei of living cells. We characterized the NLS-MBs by comparing their signal-to-noise ratios with unmodified molecular beacons and determined their efficiency of nuclear import. We demonstrated the specificity and sensitivity of the method by observing in living cells the localization and colocalization of small nuclear RNAs (snRNA) U1 and U2 at discrete foci in the nucleoplasm, and the localization of small nucleolar RNA U3 in the nucleolus. These snRNAs were chosen because of their essential roles in RNA biogenesis. The results were validated using in situ hybridization as positive control and random beacons as negative control. This novel approach may be applied to imaging other nuclear RNAs and pre-mRNAs in living cells.  相似文献   

12.
We investigated three probe design strategies used in quantitative polymerase chain reaction (PCR) for sensitivity in detection of the PCR amplicon. A plasmid with a 120-bp insert served as the DNA template. The probes were TaqMan, conventional molecular beacon (MB), and shared-stem molecular beacon (ATssMB and GCssMB). A shared-stem beacon probe combines the properties of a TaqMan probe and a conventional molecular beacon. It was found that the overall sensitivities for the four PCR probes are in the order of MB>ATssMB>GCssMB>TaqMan. The fluorescence quantum yield measurements indicate that incomplete or partial enzymatic cleavage catalyzed by Taq polymerase is the likely cause of the low sensitivities of two shared-stem beacons when compared with the conventional beacon probe. A high-fluorescence background associated with the current TaqMan probe sequence contributes to the relatively low detection sensitivity and signal-to-background ratio. The study points out that the nucleotide environment surrounding the reporting fluorophore can strongly affect the probe performance in real-time PCR.  相似文献   

13.
Traditional methods to assay enzymatic cleavage of DNA are discontinuous and time consuming. In contrast, recently developed fluorescence methods are continuous and convenient. However, no fluorescence method has been developed for single-stranded DNA digestion. Here we introduce a novel method, based on molecular beacons, to assay single-stranded DNA cleavage by single strand-specific nucleases. A molecular beacon, a hairpin-shaped DNA probe labeled with a fluorophore and a quencher, is used as the substrate and enzymatic cleavage leads to fluorescence enhancement in the molecular beacon. This method permits real time detection of DNA cleavage and makes it easy to characterize the activity of DNA nucleases and to study the steady-state cleavage reaction kinetics. The excellent sensitivity, reproducibility and convenience will enable molecular beacons to be widely useful for the study of single-stranded DNA cleaving reactions.  相似文献   

14.
Hairpin DNA sequences are widely used as probes for oligonucleotides in a broad range of assays, often as "molecular beacons". A potential disadvantage of the standard methodology for molecular beacon design is the need to add several self-complementary bases to each end of the probe, since these do not correspond to the target sequence. We describe a conceptually new method of hairpin DNA probe identification, in which a secondary structure prediction algorithm is employed to identify oligonucleotide sequences within an expressed gene having the requisite hairpin structure. Intuitively, such probes should have significantly improved performance over "traditional" hairpin probes, because they are fully complementary with the target. We present experimental evidence verifying this hypothesis for a series of hairpin probes targeting the pag gene of Bacillus anthracis.  相似文献   

15.
Hybridization kinetics and thermodynamics of molecular beacons   总被引:10,自引:6,他引:4  
Molecular beacons are increasingly being used in many applications involving nucleic acid detection and quantification. The stem–loop structure of molecular beacons provides a competing reaction for probe–target hybridization that serves to increase probe specificity, which is particularly useful when single-base discrimination is desired. To fully realize the potential of molecular beacons, it is necessary to optimize their structure. Here we report a systematic study of the thermodynamic and kinetic parameters that describe the molecular beacon structure–function relationship. Both probe and stem lengths are shown to have a significant impact on the binding specificity and hybridization kinetic rates of molecular beacons. Specifically, molecular beacons with longer stem lengths have an improved ability to discriminate between targets over a broader range of temperatures. However, this is accompanied by a decrease in the rate of molecular beacon–target hybridization. Molecular beacons with longer probe lengths tend to have lower dissociation constants, increased kinetic rate constants, and decreased specificity. Molecular beacons with very short stems have a lower signal-to-background ratio than molecular beacons with longer stems. These features have significant implications for the design of molecular beacons for various applications.  相似文献   

16.
Molecular beacons   总被引:10,自引:0,他引:10  
This opinion covers the field of molecular beacons (MBs), in which nucleic acids are molecularly engineered to have unique functions for the investigation of biomolecules. Molecular beacons have been used in a variety of formats, and this review discusses four: first, in vitro RNA and DNA monitoring; second, biosensors and biochips based on MBs; third, real-time monitoring of genes and gene expression in living systems; and finally, the next generation of molecular beacons that will be highly useful for studies with proteins, molecular beacon aptamers. These unique applications have shown that MBs holds great potential in genomics and proteomics where real-time molecular recognition with high sensitivity and excellent specificity is critical.  相似文献   

17.
van Schie RC  Marras SA  Conroy JM  Nowak NJ  Catanese JJ  de Jong PJ 《BioTechniques》2000,29(6):1296-300, 1302-4, 1306 passim
Conventional, high-throughput PCR analysis of common elements utilizing numerous primer sets and template DNA requires multiple rounds of PCR to ensure optimal conditions. Laborious gel electrophoresis and staining is then necessary to visualize amplification products. We propose novel multicolor molecular beacons, to establish a high-throughput, PCR-based sequence tagged site (STS) detection system that swiftly and accurately confirms marker content in template containing common repeat elements. A simple, one-tube, real-time PCR assay system was developed to specifically detect regions containing CA and GATA repeats. Ninety-six samples can be confirmed for marker content in a closed-tube format in 3 h, eliminating product confirmation on agarose gels and avoiding crossover contamination. Multiple STSs can be detected simultaneously in the same reaction tube by utilizing molecular beacons labeled with multicolor fluorophores. Template DNA from 260 RPCI-11 bacterial artificial chromosome (BAC) clones was examined for the presence of CA and/or GATA repeats using molecular beacon PCR and compared with conventional PCR results of the same clones. Of the 205 clones containing CA and GATA repeats, we were able to identify 129 clones (CA, n = 99; GATA, n = 30) by using molecular beacons and only 121 clones (CA, n = 92; GATA, n = 29) by conventional PCR amplification. As anticipated, 55 clones that contained sequences other than CA or GATA failed molecular beacon detection. Molecular beacon PCR, employing beacons specific for tandem repeat elements, provides a fast, accurate, and sensitive multiplex detection assay that will expedite verification of marker content in a multitude of template containing these repeats.  相似文献   

18.
Detection of Transgenes in Crop Plants Using Molecular Beacon Assays   总被引:2,自引:1,他引:1  
Molecular beacons are oligonucleotide probes that form a stem-and-loop structure and possess an internally quenched fluorophore. When they bind to complementary targets, they undergo a conformational transition that turns on their fluorescence. These probes recognise their targets with higher specificity than linear probes and can easily discriminate targets that differ from one another by a single nucleotide. As a model system to test the applicability of molecular beacons in crop plants, we have designed a molecular beacon to detect the bar transgene in barley. Results from this experiment indicate that molecular beacons can be successfully employed in detecting transgenes, simultaneously combining the benefits of being highly reproducible and sensitive. The molecular beacon assay is suitable for diagnostics, simultaneously being employed in the development of rapid DNA-based assays for analysing single nucleotide polymorphisms (SNPs).  相似文献   

19.
While molecular beacons are primarily known as biosensors for the detection of nucleic acids, it has proven possible to adapt other nucleic acid binding species (aptamers) to function in a manner similar to molecular beacons, yielding fluorescent signals only in the presence of a cognate ligand. Unfortunately, engineering aptamer beacons requires a detailed knowledge of aptamer sequence and structure. In order to develop a general method for the direct selection of aptamer beacons we have first developed a selection method for molecular beacons. A pool of random sequence DNA molecules were immobilized via a capture oligonucleotide on an affinity column, and those variants that could be released from the column by a target oligonucleotide were amplified. After nine rounds of selection and amplification the elution characteristics of the population were greatly improved. A fluorescent reporter in the selected beacons was located adjacent to a DABCYL moiety in the capture oligonucleotide; addition of the target oligonucleotide led to release of the capture oligonucleotide and up to a 17-fold increase in fluorescence. Signaling was specific for the target oligonucleotide, and occurred via a novel mechanism, relative to designed molecular beacons. When the target oligonucleotide is bound it can form a stacked helical junction with an intramolecular hairpin in the selected beacon; formation of the intramolecular hairpin in turn leads to release of the capture oligonucleotide. The ability to select molecular beacons may prove useful for identifying available sites on complex targets, such as mRNAs, while the method for selection can be easily generalized to other, non-nucleic acid target classes.  相似文献   

20.
分子信标核酸检测技术研究进展   总被引:13,自引:0,他引:13  
介绍了分子信标设计和分子信标核酸检测原理、技术特性和在基因突变大规模自动化检测中的应用. 分子信标是一种基于荧光共振能量转移现象设计的发卡型寡核苷酸探针,空间结构上呈茎环结构, 环序列是与靶核酸互补的探针,茎序列由与靶序列无关的互补序列构成,茎的一端连上荧光分子,另一端连上淬灭分子.通过空间结构改变决定分子信标发射荧光特性,从而对核酸进行定量检测. 分子信标技术具有操作简单、敏感、特异、可对核酸进行液相实时检测和对活体内核酸动态进行检测等特点,已应用于HIV辅助受体基因等基因突变的大规模自动化检测,是一种新型核酸定量检测技术.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号