首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The identification and characterization of proteins in complex biological samples such as body fluids, require powerful and reliable tools. Mass spectrometry is today one of the most important methods in such research. This paper reports on the results from the first experiment where a tryptic digest of cerebrospinal fluid was analyzed applying reversed phase liquid chromatography coupled on-line to a 9.4 T Fourier transform ion cyclotron resonance mass spectrometer. In total, 70 204 peaks were detected, which originated from 16 296 isotopic clusters corresponding to 6551 unique peptide masses. From these masses, 39 proteins were identified in the sample. The amount of sample required for one experiment corresponds to 32 microL of cerebrospinal fluid.  相似文献   

2.
Ihling C  Sinz A 《Proteomics》2005,5(8):2029-2042
The basic problem of complexity poses a significant challenge for proteomic studies. To date two-dimensional gel electrophoresis (2-DE) followed by enzymatic in-gel digestion of the peptides, and subsequent identification by mass spectrometry (MS) is the most commonly used method to analyze complex protein mixtures. However, 2-DE is a slow and labor-intensive technique, which is not able to resolve all proteins of a proteome. To overcome these limitations gel-free approaches are developed based on high performance liquid chromatography (HPLC) and Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). The high resolution and excellent mass accuracy of FT-ICR MS provides a basis for simultaneous analysis of numerous compounds. In the present study, a small protein subfraction of an Escherichia coli cell lysate was prepared by size-exclusion chromatography and proteins were analyzed using C4 reversed phase (RP)-HPLC for pre-separation followed by C18 RP nanoHPLC/nanoESI FT-ICR MS for analysis of the peptide mixtures after tryptic digestion of the protein fractions. We identified 231 proteins and thus demonstrated that a combination of two RP separation steps - one on the protein and one on the peptide level - in combination with high-resolution FT-ICR MS has the potential to become a powerful method for global proteomics studies.  相似文献   

3.
This study demonstrates the power of a novel proteomic approach developed for the detection and identification of biological markers in body fluids. The goal was to observe alterations in the protein patterns of cerebrospinal fluid (CSF) related to amyotrophic lateral sclerosis (ALS), a neurodegenerative disorder with unknown etiology. In the experiments, tryptic digests of CSF from patients and healthy controls were analyzed by on-line capillary liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometry. (FT-ICR MS) Typically, around 4000 peptides were detected in one such experiment, and a pattern recognition program was constructed for the data analysis to distinguish mass chromatograms from patients and controls. This strategy was evaluated comparing the peptide patterns of CSF spiked in vitro with a biomarker, with control CSF. The patterns were clearly separated and the tryptic peptides of the biomarker were successfully selected as characteristic peaks. Hence, the method was applied to compare mass chromatograms of CSF from 12 ALS-patients and 10 matched healthy controls. While no biomarker alone could be identified from the characteristic peaks, we were able to assign 4 out of 5 unknown samples correctly (i.e., 80% correctly diagnosed, 20% false-negative), and it would be 100% if we reject a possible outlier believed to be caused by an occlusion in the spinal CSF compartment. These findings are very promising, although the clinical relevance is not fully established due to the low number of unknown samples analyzed. In addition to the diagnostic potential, these results may be important steps towards understanding the neurodegenerative process.  相似文献   

4.
Proteomics analysis using tandem mass spectrometry requires informative backbone fragmentation of peptide ions. Collision-activated dissociation (CAD) of cations alone is not sufficiently informative to satisfy all requirements. Thus, there is a need to supplement CAD with a complementary fragmentation technique. Electron capture dissociation (ECD) is complementary to collisional excitation in terms of the cleavage of a different bond (N-Cα versus C-N bond) and other properties. CAD-ECD combination improves protein identification and enables high-throughput de novo sequencing of peptides. ECD and its variants are also useful in mapping labile post-translational modifications in proteins and isomer differentiation; for example, distinguishing Ile from Leu, iso-Asp from Asp and even D- from L-amino acid residues.  相似文献   

5.
The pharmaceutical industry’s interest in monoclonal antibodies (mAbs) and their derivatives has spurred rapid growth in the commercial and clinical pipeline of these effective therapeutics. The complex micro-heterogeneity of mAbs requires in-depth structural characterization for critical quality attribute assessment and quality assurance. Currently, mass spectrometry (MS)-based methods are the gold standard in mAb analysis, primarily with a bottom-up approach in which immunoglobulins G (IgGs) and their variants are digested into peptides to facilitate the analysis. Comprehensive characterization of IgGs and the micro-variants remains challenging at the proteoform level. Here, we used both top-down and middle-down MS for in-depth characterization of a human IgG1 using ultra-high resolution Fourier transform MS. Our top-down MS analysis provided characteristic fingerprinting of the IgG1 proteoforms at unit mass resolution. Subsequently, the tandem MS analysis of intact IgG1 enabled the detailed sequence characterization of a representative IgG1 proteoform at the intact protein level. Moreover, we used the middle-down MS analysis to characterize the primary glycoforms and micro-variants. Micro-variants such as low-abundance glycoforms, C-terminal glycine clipping, and C-terminal proline amidation were characterized with bond cleavages higher than 44% at the subunit level. By combining top-down and middle-down analysis, 76% of bond cleavage (509/666 amino acid bond cleaved) of IgG1 was achieved. Taken together, we demonstrated the combination of top-down and middle-down MS as powerful tools in the comprehensive characterization of mAbs.  相似文献   

6.
The advent of high-throughput proteomic technologies for global detection and quantitation of proteins creates new opportunities and challenges for those seeking to gain greater understanding of the cellular machinery. Here, recent advances in high-resolution capillary liquid chromatography coupled to Fourier transform ion cyclotron resonance mass spectrometry are reviewed along with its potential application to high-throughput proteomics. These technological advances combined with quantitative stable isotope labeling methodologies provide powerful tools for expanding our understanding of biology at the system level.  相似文献   

7.
All major fragment ions of codeine and morphine were elucidated using LC-electrospray MS/MS and high resolution FT-ICR-MS combined with an IRMPD system. Nanogram quantities of labeled codeine were isolated and purified from Papaver somniferum seedlings, which were grown for up to 9 days in the presence of [ring-13C6]-l-tyrosine, [ring-13C6]-tyramine and [1,2-13C2], [6-O-methyl 13C]-(R,S)-coclaurine. The labeling degree of codeine up to 57% into morphinans was observed.  相似文献   

8.
Electron capture dissociation (ECD) represents a significant advance in tandem mass spectrometry for the identification and characterization of post-translational modifications (PTMs) of polypeptides. In comparison with the conventional fragmentation techniques, such as collisionally induced dissociation and infrared multi-photon dissociation, ECD provides more extensive sequence fragments, while allowing the labile modifications to remain intact during backbone fragmentation. This unique attribute offers ECD as an attractive alternative for detection and localization of PTMs. The success and rapid adoption of ECD recently led to the culmination of The 1st International Uppsala Symposium on Electron Capture Dissociation of Biomolecules and Related Phenomena (October 19-22, 2003, Stockholm, Sweden). Herein, we present a general overview of the ECD technique as well as selected applications in characterization of post-translationally modified polypeptides.  相似文献   

9.
Nakamura T  Dohmae N  Takio K 《Proteomics》2004,4(9):2558-2566
We describe a new approach for the characterization of a digested protein complex with quantitative aspects. Accurate masses of tryptic peptides in the digested complex were acquired by nano-liquid chromatography Fourier transform-ion cyclotron resonance mass spectrometry (MS). The conditions of the electrospray ion source were alternated to acquire normal and fragment-ion-rich mass spectra concurrently. This, alternating-scan method, which includes no tandem mass spectrometry (MS/MS), allowed us to retain the integrity of the mass chromatograms and averted missed peptides due to MS and MS/MS switching. Tentative assignments of accurate peptide masses were verified with the concurrently acquired fragment-ion-rich spectra, and the identities of the protein components were established. For each identified protein component, mass chromatograms attributable to the validated accurate peptide masses were extracted, and the peak areas of multiple mass chromatograms were standardized. The standardized peak areas appeared to reasonably reflect the molar ratio of the protein components in standard mixtures. This new approach was successfully applied to the characterization of a cyanobacterial photosystem II complex preparation. A clear difference in the standardized peak areas was observed between the two groups of identified components, namely eight stoichiometric photosystem II proteins and two minor copurified phycobiliproteins.  相似文献   

10.
Papaver alkaloids play a major role in medicine and pharmacy. In this study, [ring-(13)C(6)]-tyramine as a biogenetic precursor of these alkaloids was fed to Papaver somniferum seedlings. The alkaloid pattern was elucidated both by direct infusion high-resolution ESI-FT-ICR mass spectrometry and liquid chromatography/electrospray tandem mass spectrometry. Thus, based on this procedure, the structure of about 20 alkaloids displaying an incorporation of the labeled tyramine could be elucidated. These alkaloids belong to different classes, e.g. morphinan, benzylisoquinoline, protoberberine, benzo[c]phenanthridine, phthalide isoquinoline and protopine. The valuable information gained from the alkaloid profile demonstrates that the combination of these two spectrometric methods represents a powerful tool for evaluating biochemical pathways and facilitates the study of the flux of distant precursors into these natural products.  相似文献   

11.
Electron capture dissociation (ECD) represents one of the most recent and significant advancements in tandem mass spectrometry (MS/MS) for the identification and characterization of polypeptides. In comparison with the conventional fragmentation techniques, such as collisionally activated dissociation (CAD), ECD provides more extensive sequence fragments, while allowing the labile modifications to remain intact during backbone fragmentation—an important attribute for characterizing post-translational modifications. Herein, we present a brief overview of the ECD technique as well as selected applications in characterization of peptides and proteins. Case studies including characterization and localization of amino acid glycosylation, methionine oxidation, acylation, and “top–down” protein mass spectrometry using ECD will be presented. A recent technique, coined as electron transfer dissociation (ETD), will be also discussed briefly.  相似文献   

12.
Infrared multiphoton dissociation (IRMPD) of deprotonated and protonated oligonucleotides ranging from 5 to 40 residues has been performed in a quadrupole ion trap mass spectrometer at normal operating pressure and temperature. Only moderate exposure times and laser powers were required to achieve efficient dissociation. In general, IRMPD and collisionally activated dissociation (CAD) produce comparable sequencing information, indicating that IRMPD is a viable alternative to CAD for oligonucleotide analysis in the quadrupole ion trap. Two major characteristics distinguish CAD and IRMPD spectra for a given parent ion. First, structurally uninformative M-B ions that dominate CAD spectra are generally only low-intensity species in IRMPD spectra because nonresonant activation causes these species to dissociate to backbone cleavage products. Second, phosphate and nucleobase ions can be observed directly in IRMPD experiments because the low-mass cutoff can be set to trap small fragment ions. For this reason IRMPD can sometimes facilitate analysis of sequences containing modified bases.  相似文献   

13.
D-erythro-Sphingosine is known to be phosphorylated by sphingosine kinase to yield sphingosine-1-phosphate. With the importance of sphingosine-1-phosphate in biological functions being made evident by recent research, a selective and convenient method of assay to measure sphingosine kinase activity is required. Here we developed a new sphingosine kinase assay using murine teratocarcinoma mutant F9-12 cells and electrospray ionization tandem mass spectrometry (ESI–MS/MS) with direct infusion. Sphingosine-1-phosphate in the crude extract of enzyme reaction mixture was selectively characterized and quantitated using precursor ion scanning for [PO3]- in the negative electrospray ionization mode. The method was successfully validated for an activator and an inhibitor of sphingosine kinase. Direct quantitation of S1P without the use of radioactive reagents, chemical derivatization, and extensive chromatographic separation enables simplified assay for sphingosine kinase activity at the cellular system level, and the use of a structural analog as an internal standard provides robustness to the assay.  相似文献   

14.
High-efficiency prefractionation of complex protein mixtures is critical for top-down proteomics, i.e., the analysis of intact proteins by MS. Free-flow electrophoresis (FFE) can be used for IEF to separate proteins within a pH gradient according to their pIs. In an FFE system, this separation is performed entirely in the liquid phase, without the need for particulate chromatographic media, gels, or membranes. Herein, we demonstrated the compatibility of IEF-FFE with ESI-Fourier transform ICR MS (ESI-FTICR-MS) for top-down experiments. We demonstrated that IEF-FFE of intact proteins were highly reproducible between FFE instruments, between laboratories, and between analyses. Applying native (0.2% hydroxypropylmethyl cellulose) IEF-FFE to an enzyme resulted in no decrease in enzyme activity; applying either native or denaturing (8 M urea) IEF-FFE to a four-protein mixture with different pIs resulted in isolation of each protein into separate fractions in a 96-well plate. After desalting, each protein was sequenced by top-down MS/MS. As an application of this technique, chicken erythrocyte histone H2A-IV and its major modified forms were enriched by IEF-FFE. Top-down analysis revealed Lys-5 to be a major acetylation site, in addition to N-terminal acetylation.  相似文献   

15.
Fourier transform mass spectrometry has recently been introduced into the field of metabolomics as a technique that enables the mass separation of complex mixtures at very high resolution and with ultra high mass accuracy. Here we show that this enhanced mass accuracy can be exploited to predict large metabolic networks ab initio, based only on the observed metabolites without recourse to predictions based on the literature. The resulting networks are highly information-rich and clearly non-random. They can be used to infer the chemical identity of metabolites and to obtain a global picture of the structure of cellular metabolic networks. This represents the first reconstruction of metabolic networks based on unbiased metabolomic data and offers a breakthrough in the systems-wide analysis of cellular metabolism.  相似文献   

16.
Losses of proteolytic peptides during extraction and/or purification procedures succeeding in-gel or in-solution digests of proteins frequently occur in the course of protein identification investigations. In order to overcome this disadvantage, the method of in-capillary digest was developed: native proteins were incubated in the presence of endoproteases in the electrospray capillary and the resulting peptides were analyzed by nanoelectrospray-mass spectrometry during the ongoing proteolysis. In-capillary digest of apomyglobin by use of trypsin in a molar ratio of 25:1 yielded complete degradation already after 15 min. The sequence coverage based on formation of molecular ions was 100% and peptide ions could be fragmented by collision-induced dissociation and sequenced. When myoglobin was incubated in the electrospray capillary with trypsin in a molar ratio of 500:1, a clear shift from molecular ions and miscleaved peptide ions to the expected final tryptic peptide ions was observed over a 2 h period. The peptide spectra obtained from tryptic in-capillary proteolysis of bovine serum albumin and apotransferrin, respectively, gave rise to sequence coverages of more than 40% for both proteins. The data obtained from the peptide maps as well as from collision-induced dissociation (CID) of selected peptides were more than sufficient for protein identification by database searches. An elephant milk protein preparation was used to demonstrate the application of in-capillary proteolysis on protein mixtures. Tryptic digest, simultaneous analysis of the proteolytic peptides by use of CID, and subsequent sequencing allowed the identification of lactoferrin, alphas1-casein, beta-casein, delta-casein, and kappa-casein by homology search.  相似文献   

17.
Kamleh MA  Hobani Y  Dow JA  Watson DG 《FEBS letters》2008,582(19):2916-2922
Hydrophilic interaction chromatography (HILIC) interfaced with an Orbitrap Fourier transform mass spectrometer (FT-MS) was used to carry out metabolomic profiling of the classical Drosophila mutation, rosy (ry). This gene encodes a xanthine oxidase/dehydrogenase. In addition to validating the technology by detecting the same changes in xanthine, hypoxanthine, urate and allantoin that have been reported classically, completely unsuspected changes were detected in each of the tryptophan, arginine, pyrimidine and glycerophospholipid metabolism pathways. The rosy mutation thus ramifies far more widely than previously detected.  相似文献   

18.
The solvent-accessible surface area of proteins is important in biological function for many reasons, including protein-protein interactions, protein folding, and catalytic sites. Here we present a chemical technique to oxidize amino acid side chains in a model protein, apomyoglobin, and subsequent elucidation of the effect of solvent accessibility on the sites of oxidation. Under conditions of low protein oxidation (zero to three oxygen atoms added per apomyoglobin molecule), we have positively identified five oxidation sites by liquid chromatography-tandem mass spectrometry and high-resolution Fourier transform mass spectrometry. Our results indicate that all oxidized amino acids, with the exception of methionine, have highly solvent-accessible side chains, but the rate of oxidation may not be dictated solely by solvent accessibility and amino acid identity.  相似文献   

19.
Whereas the bearing of mass measurement error on protein identification is sometimes underestimated, uncertainty in observed peptide masses unavoidably translates to ambiguity in subsequent protein identifications. Although ongoing instrumental advances continue to make high accuracy mass spectrometry (MS) increasingly accessible, many proteomics experiments are still conducted with rather large mass error tolerances. In addition, the ranking schemes of most protein identification algorithms do not include a meaningful incorporation of mass measurement error. This article provides a critical evaluation of mass error tolerance as it pertains to false positive peptide and protein associations resulting from peptide mass fingerprint (PMF) database searching. High accuracy, high resolution PMFs of several model proteins were obtained using matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry (MALDI-FTICR-MS). Varying levels of mass accuracy were simulated by systematically modulating the mass error tolerance of the PMF query and monitoring the effect on figures of merit indicating the PMF quality. Importantly, the benefits of decreased mass error tolerance are not manifest in Mowse scores when operating at tolerances in the low parts-per-million range but become apparent with the consideration of additional metrics that are often overlooked. Furthermore, the outcomes of these experiments support the concept that false discovery is closely tied to mass measurement error in PMF analysis. Clear establishment of this relation demonstrates the need for mass error-aware protein identification routines and argues for a more prominent contribution of high accuracy mass measurement to proteomic science.  相似文献   

20.
A strategic method with high speed and sensitivity is outlined for the analysis of mucin-type oligosaccharide from the jelly coat of Xenopus laevis. The method relies primarily on mass spectrometric techniques, in this case matrix-assisted laser desorption/ionization Fourier-transform mass spectrometry (MALDI-FTMS) and collision-induced dissociation (CID). Separation with isolation of the oligosaccharides was streamlined to couple well with mass spectrometry allowing the rapid determination of all detectable components from both neutral and anionic species. Partial structures of anionic components, composed primarily of sulfate esters, were obtained with CID. For neutral species, a method that allowed the complete structural determination using mass spectrometry was used. The method builds on the structure of small number of known compounds to determine unknown structures from the same biological source. In this example, a small number of oligosaccharides, elucidated previously by NMR, were used to develop a set of substructural motifs that were characterized by CID. The presence of the motifs in the CID spectra were then used to determine the structures of unknown compounds that were in abundances too small for NMR analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号