首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The tube coagulase test is a valid means of identifying Staphylococcus auerus, provided that only a firm clot that does not move when the tube is tipped is considered a positive reaction. The widely promulgated interpretation that all degrees of clotting in coagulase plasma are a positive identification of S. auerus was disproved by the use of other tests such as anaerobic glucose fermentation, thermonuclease production, and lysostaphin sensitivity. It was found that the source of supply of the coagulase plasma is a factor in the occurrence of false-positive coagulase test results. The use of a mixture of pig and rabbit plasma in the tube coagulase test is also discussed.  相似文献   

2.
In optimizing previously reported coagulase agar media to obtain a rapid, reliable, and inexpensive coagulase test agar, variations in plasmas, pH, buffer system, fibrinogen, and fibrinolytic inhibitor were investigated. The agar with the following composition was determined best for the demonstration of coagulase production by Staphylococcus aureus: 25 ml of 15% bovine fibrinogen (fraction I, type I, citrated, Sigma Chemical Co.), 25 ml of rehydrated rabbit plasma (coagulase plasma ethylenediaminetetraacetic acid, Difco), 10.0 mg of soybean trypsin inhibitor (Schwarz/Mann), and 450 ml of brain heart infusion agar (Difco). In additional studies involving 7 different temperatures and 11 heating times, the thermal destruction of microbial nucleases on plate count agar and coagulase test agar was investigated. Heating the plates for 2.5 h at 65 degrees C destroyed all heatlabile nucleases, but not thermonucleases of S. aureus. A tandem agar plate method for the identification of S. aureus was developed. Coagulase and thermonuclease activity of 50 colonies can be detected on a single agar plate. Suspect S. aureus colonies isolated on various selective media are transferred to coagulase test agar, the plates are incubated at 37 degrees C for 18 h, and the coagulase reaction is recorded. The plates are then heated at 65 degrees C for 2.5 h, overlaid with toluidine blue-metachromatic diffusion agar, and reincubated at 37 degrees C for 3 h, and the thermonuclease reaction is recorded. Studies based on 88 enterotoxigenic S. aureus strains and 133 and 48 suspect S. aureus strains isolated from fresh salami mixtures on mannitol salt and tellurite-polymyxin-egg yolk agars, respectively, demonstrated 100% agreement between the tandem agar plate method and standard coagulase and thermonuclease tests. Overall, the tandem agar plate method is a rapid and convenient approach contributing to the identification of S. aureus from foods.  相似文献   

3.
In optimizing previously reported coagulase agar media to obtain a rapid, reliable, and inexpensive coagulase test agar, variations in plasmas, pH, buffer system, fibrinogen, and fibrinolytic inhibitor were investigated. The agar with the following composition was determined best for the demonstration of coagulase production by Staphylococcus aureus: 25 ml of 15% bovine fibrinogen (fraction I, type I, citrated, Sigma Chemical Co.), 25 ml of rehydrated rabbit plasma (coagulase plasma ethylenediaminetetraacetic acid, Difco), 10.0 mg of soybean trypsin inhibitor (Schwarz/Mann), and 450 ml of brain heart infusion agar (Difco). In additional studies involving 7 different temperatures and 11 heating times, the thermal destruction of microbial nucleases on plate count agar and coagulase test agar was investigated. Heating the plates for 2.5 h at 65°C destroyed all heatlabile nucleases, but not thermonucleases of S. aureus. A tandem agar plate method for the identification of S. aureus was developed. Coagulase and thermonuclease activity of 50 colonies can be detected on a single agar plate. Suspect S. aureus colonies isolated on various selective media are transferred to coagulase test agar, the plates are incubated at 37°C for 18 h, and the coagulase reaction is recorded. The plates are then heated at 65°C for 2.5 h, overlaid with toluidine blue-metachromatic diffusion agar, and reincubated at 37°C for 3 h, and the thermonuclease reaction is recorded. Studies based on 88 enterotoxigenic S. aureus strains and 133 and 48 suspect S. aureus strains isolated from fresh salami mixtures on mannitol salt and tellurite-polymyxin-egg yolk agars, respectively, demonstrated 100% agreement between the tandem agar plate method and standard coagulase and thermonuclease tests. Overall, the tandem agar plate method is a rapid and convenient approach contributing to the identification of S. aureus from foods.  相似文献   

4.
Improved methods for detection and serotyping of staphylocoagulase were concomitantly devised. We devised an improved method for detection of coagulase activity on agarose film in the same manner as single radial immunodiffusion. The amounts of reagents required for detection of coagulase on agarose film were successfully diminished by adding polyethylene glycol (PEG) to the original formula described by Boothby et al. Using microplates in another improved method for coagulase serotyping, the amount of reaction fluid required was considerably less compared with the conventional tube method. PEG was found to be also effective to increase the efficacy of coagulase serotyping. In the presence or absence of anti-coagulase antisera, culture supernatants of staphylococcal strain grown in brain heart infusion broth were incubated with the reaction fluid containing bovine fibrinogen, rabbit plasma, 6-amino caproic acid, polyethylene glycol 6,000. Coagulase activity was visualized as a turbid mass formed in the wells. Turbid mass formation due to coagulase activity was type-specifically inhibited in the presence of type-specific antisera. Detailed procedures of the methods are precisely described with some preliminary results obtained by the methods.  相似文献   

5.
Nephelometric assay of staphylococal coagulase   总被引:5,自引:1,他引:4  
Stutzenberger, Fred J. (Michigan State University, East Lansing), Charles L. San Clemente, and Dharam V. Vadehra. Nephelometric assay of staphylococcal coagulase. J. Bacteriol. 92:1005-1009. 1966.-Clotting of fibrinogen by staphylococcal coagulase was accompanied by an increase in light scattering; this property was used as a basis for a new nephelometric method. Reaction rates, which were now easily and precisely measured, were found to be directly proportional to coagulase concentration, when optimal conditions were maintained. These conditions included pH and concentrations of fibrinogen, coagulase-reacting factor, and sodium chloride in the reaction mixture. A standardized procedure for the assay is outlined, and a unit for the expression of activity is proposed.  相似文献   

6.
A total of 195 Gram positive, catalase positive cocci, isolated from ovine mastitis, abscesses in slaughtered animals and parasitic pulmonary lesions in lambs were tested for glucose fermentation, anaerobic growth in thioglycollate medium, coagulase production and susceptibility to the lytic action of lysostaphin. On the basis of lysostaphin sensitivity, 192 strains were classified as staphylococci. The number of cultures able to produce acid anaerobically from glucose, or giving a positive result in the test of Evans and Kloos was lower. A good correlation among these three tests was not observed. Ninety-seven of the strains tested gave a positive coagulase reaction. Sensitivity to lysostaphin could not be used as a criterion for the differentiation of coagulase positive and coagulase negative strains. The turbidimetric method employed for the assessment of lysostaphin sensitivity is discussed.  相似文献   

7.
A novel simultaneous measurement method for alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) in human sera by time-resolved fluoroimmunoassay (TR-FIA) is described. The proposed approach combines the use of europium-labeled anti-AFP antibody for AFP TR-FIA and biotinylated anti-CEA antibody complexed to samarium-labeled streptavidin for CEA TR-FIA. A 96-well microtiter plate coated with a mixture of anti-AFP and anti-CEA monoclonal antibodies was used for the assay. After it was reacted with a solution containing AFP and CEA, a mixture of anti-AFP antibody labeled with BHHCT-Eu(3+) and biotinylated anti-CEA antibody was added. The AFP concentration was determined by measuring the solid-phase fluorescence of the europium-labeled anti-AFP antibody at 615 nm. Then a BHHCT-Sm(3+)-labeled streptavidin-bovine serum albumin conjugate (SA-BSA) was added to react with the biotinylated anti-CEA antibody. After the reaction, the unreacted SA-BSA was washed out, and a 0.1 M NaOH solution containing 1.0 x 10(-5) M TOPO and 0.05% SDS was added to dissociate the samarium-labeled SA-BSA in the immune complex on the surface of the well into the solution. The CEA concentration was determined by measuring the solution fluorescence of 643 nm from the samarium-labeled SA-BSA. The present method gives detection limits of 0.07 ng/ml for AFP and 0.3 ng/ml for CEA. The coefficient variations of the method are less than 7%, and the recoveries are in the range of 90-110% for serum samples. The AFP and CEA concentrations in 27 human serum samples were determined by the present method as well as by single assay for comparison. A good correlation was obtained with the correlation coefficients of 0.990 for AFP and 0.973 for CEA.  相似文献   

8.
To further improve the selectivity and throughput of phosphopeptide analysis for the samples from real-time cell lysates, here we demonstrate a highly efficient method for phosphopeptide enrichment via newly synthesized magnetite microparticles and the concurrent mass spectrometric analysis. The magnetite microparticles show excellent magnetic responsivity and redispersibility for a quick enrichment of those phosphopeptides in solution. The selectivity and sensitivity of magnetite microparticles in phosphopeptide enrichment are first evaluated by a known mixture containing both phosphorylated and nonphosphorylated proteins. Compared with the titanium dioxide-coated magnetic beads commercially available, our magnetite microparticles show a better specificity toward phosphopeptides. The selectively-enriched phosphopeptides from tryptic digests of β-casein can be detected down to 0.4 fmol μl−1, whereas the recovery efficiency is approximately 90% for monophosphopeptides. This magnetite microparticle-based affinity technology with optimized enrichment conditions is then immediately applied to identify all possible phosphorylation sites on a signal protein isolated in real time from a stress-stimulated mammalian cell culture. A large fraction of peptides eluted from the magnetic particle enrichment step were identified and characterized as either single- or multiphosphorylated species by tandem mass spectrometry. With their high efficiency and utility for phosphopeptide enrichment, the magnetite microparticles hold great potential in the phosphoproteomic studies on real-time samples from cell lysates.  相似文献   

9.
蕲蛇酶抗栓作用机理的初步分析   总被引:20,自引:6,他引:14  
王晴川  刘广芬 《蛇志》1997,9(3):9-11
动物实验结果示,蕲蛇酶能裂解纤维蛋白原成为可溶性纤维蛋白,降低血中纤维蛋白原浓度,抑制血小板聚集,对抗在酶诱导的血浆凝块订的血浆凝块回缩,因而发挥防血栓形成作用。对纤维蛋白平板试验无直接溶纤作用,但能增加实验动物血中t-PA活性。可能通过促使血管内皮细胞释放t-PA而发挥溶栓作用。  相似文献   

10.
在进行固相ELISA双夹心法时,要选择两种配对的单克隆抗体(McAb)殊非易事。本文用不同McAb的混合物与另一种McAb进行配对夹心,获得了较好的效果。实验表明,在心肌肌球蛋白轻链(CM—LC)的固相ELISA双夹心体系中,以抗CM-LCMcAb(1G6)铺底,(2B4及2F6)混合物为后续复盖抗体,最低检出量可低达10ng/mL,其检出率较单独2B4或单独2F6作为后续复盖抗体者高5—10倍。而若反之,以(2B4及2F6)混合物铺底,1G6作为后续复盖抗体,则其最低检出量竟高至200ng/mL,还不如以其中之一铺底为佳。在人绒毛膜促性腺激素(HCG)的检测体系中,用多克隆抗体与单克隆抗体配对的研究中,也获得了类似的实验结果。  相似文献   

11.
Encapsulated and nonencapsulated strains of Staphylococcus aureus which lack coagulase or clumping factor (bound coagulase), or both, were examined for the antigen associated with the fibrinogen-cell clumping reaction. Extracts of the cells were tested for the ability to react with fibrinogen or to inhibit fibrinogen precipitation. Antisera prepared against encapsulated (coagulase-positive, clumping factor-negative) variants, as well as against nonencapsulated wild-type (coagulase-positive, clumping factor-positive) S. aureus strains, contained high titers of clumping-inhibiting antibody. When coagulase-negative, clumping factor-negative mutants were the immunizing agents, antisera contained no demonstrable clumping-inhibiting antibody. Phenol extracts of all coagulase-positive strains tested precipitated fibrinogen, regardless of the ability of cells to clump in the presence of fibrinogen. Polysaccharide extracts of encapsulated, clumping factor-negative strains inhibited this fibrinogen-precipitating activity, whereas similar extracts of nonencapsulated staphylococci did not inhibit the fibrinogen reaction. From these results, it appeared that the coagulase-positive, encapsulated staphylococci which do not clump in fibrinogen solution possess clumping factor, but that their capsular polysaccharide inhibits clumping activity. These findings suggested a closer association of clumping factor and coagulase than is now recognized.  相似文献   

12.
A simple, sensitive, and specific assay method for glycosyltransferase and glycosidase activities has been established by means of an enzyme-linked immunosorbent assay (ELISA) using monoclonal antibody, H-11 directed to lactoneotetraosylceramide (nLc4Cer). Enzyme activity was determined by assaying the amount of reaction product, nLc4Cer with the ELISA method. For the assay of galactosyltransferase activity, lactotriaosylceramide (Lc3Cer) immobilized on a 96-well microtiter plate was incubated with bovine milk galactosyltransferase in cacodylate buffer (pH 6.8) containing Triton CF-54, Mn2+, and UDP-galactose. Optimum incubation conditions for the enzyme were determined. Glycosidase activity was also assayed by the ELISA method by using Clostridium perfringens sialidase and neolacto-series gangliosides as substrates, and the substrate specificities towards the gangliosides were examined. By this method, 3-100 pmol of reaction product could be determined. The assay method has several advantages as follows: 1, the method is simple; 2, separation of the reaction product is not required; 3, quantification and identification of the reaction product were done simultaneously; 4, naturally occurring substrates are available (especially for glycosidase); 5, many samples can be assayed in one microplate; 6, sensitivity is very high. The present method was applied for the detection of galactosyltransferase in human sera. Significant elevations of the galactosyltransferase levels were observed in the sera from cancer patients. The formation of nLc4Cer was confirmed by employing the TLC-immunostaining method for bands of Lc3Cer after incubation of the bands with serum and cofactors on an HPTLC plate.  相似文献   

13.
Electron microscopic studies of viruses labeled with magnetite   总被引:1,自引:0,他引:1  
We were able to develop a method with which to successfully and specifically detect virus particles under the electron microscope by using magnetite. This method was devised on the principle that magnetite-labeled antibody or magnetite coupled with protein A selectively bind virus or antibody-treated virus particles on the electron microscope grid by the action of an electromagnet. Another advantage characterizing the technique is the possibility of detection of a small number of virus particles. This is done through a process of concentration and purification of the reaction complexes trapped rigidly by magnetic force.  相似文献   

14.
Fibronectin and fibrin gel structure   总被引:4,自引:0,他引:4  
Plasma fibronectin is covalently incorporated into alpha-chains of fibrin gels in the presence of Factor XIII activated by thrombin (FXIIIaT) but not by Factor XIII activated by the snake venom enzyme batroxobin (FXIIIaB). FXIIIaB catalyzes introduction of gamma-gamma cross-links in fibrin but cross-linked alpha-chains are not formed. In the presence of FXIIIaT, fibrin gels formed by batroxobin incorporated fibronectin and the alpha-chains are cross-linked indicating that FXIIIaB has a different substrate specificity from FXIIIaT. In the presence of FXIIIaT the incorporation of fibronectin approaches 1 mol/340 kDa unit weight of fibrin. Fibronectin when present in a fibrinogen thrombin mixture containing FXIII does not influence the clotting time of the system nor the release of fibrinopeptides. Incorporation of fibronectin is not appreciable before the gel point. This indicates that the polymerization and gelation of fibrinogen is essentially not perturbed by the presence of fibronectin and that fibrin in the gel matrix rather than the fibrin polymers formed prior to gel point is the preferred structure for fibronectin incorporation. Incorporation of fibronectin into fibrin gels during formation leads to an increase in turbidity and a small decrease in Ks (permeability coefficient). This suggests that the width of the strands in the gel increases as a result of fibronectin incorporation. Fibronectin is also incorporated into preformed gels having completely cross-linked gamma- and alpha-chains perhaps indicating that the sites in fibrin involved in fibronectin incorporation are different from those involved in fibrin cross-linking. FXIIIaT appeared to be adsorbed to fibrin gel matrix in the presence but not in the absence of calcium ions.  相似文献   

15.
Intraalveolar fibrin formation is a common histopathological finding in acute inflammatory and chronic interstitial lung diseases. Incorporation of hydrophobic surfactant components into polymerizing fibrin results in a severe loss of surface activity, altered mechanical and structural clot properties, and a reduced susceptibility toward fibrinolytic degradation. Such events have been implicated in atelectasis formation, impairment of gas exchange, and provocation of fibroproliferative changes. In an effort to address the unique features of alveolar fibrin, we designed a hybrid molecule consisting of a monoclonal antibody against surfactant protein SP-B (8B5E) and the catalytic domain of urokinase (B-chain), which was termed MABUC. The urokinase B-chain was prepared by limited reduction of human two-chain-urokinase and subsequent affinity purification and coupled to the antibody using a heterobifunctional cross-linker. Purification of the chimeric protein included gel filtration chromatography and affinity chromatography. An ELISA-like microtiter plate assay, based on the immunological detection of the SP-B moiety and the fibrinolytic activity of the u-PA domain, was developed for the detection of the hybrid molecule. Chromogenic substrate assays, (125)I-based fibrin plate assays, and active site titration were performed to analyze the specific fibrinolytic activity of the conjugate. MABUC was found to fully retain the ability of SP-B binding and the fibrinolytic activity of u-PA. In addition, MABUC was noted to be 1.5-2-fold more effective in the dissolution of surfactant embedding clots and to be approximately 3-fold more resistant against PAI-1, the predominant fibrinolysis inhibitor in the alveolar compartment, as compared to the native u-PA. The superiority of MABUC was particularly prominent (>5-fold efficacy) when investigating clot material incorporating both PAI-1 and surfactant, as a mimicry of alveolar fibrin. We conclude that urokinase and 8B5E can be cross-linked chemically, thus yielding a fibrinolytic enzyme with enhanced substrate specifity for surfactant-containing clots and higher PAI-1 resistance as compared to native u-PA.  相似文献   

16.
华广虻溶纤活性蛋白 (TAFP)经血纤蛋白平板法和试管凝块法测定表明 ,TAFP只具有纤溶酶作用 ,不具有激活纤溶酶原的作用 .TAFP的最适 p H为 7.5,且在 p H为 6.0时最稳定 .蛋白水解酶抑制剂对 TAFP的抑制作用显示 :STI>antipain>SBBI>antitrypsin>TLCK>leupeptin>bacteracin>PMSF>TPCK,金属蛋白酶抑制剂 1 ,1 0 - phenanthroline对 TAFP没有抑制作用 .TAFP能显著的延长大鼠出血时间、抑制血小板聚集性 ;显著降低血浆中血纤蛋白原含量、全血粘度、血浆粘度、红细胞压积 ;减慢血沉速度  相似文献   

17.
目的讨论β-葡萄糖醛酸苷酶+凝固酶检测技术诊断需氧菌阴道炎(AV)的临床价值。方法分别采用镜检法和β-葡萄糖醛酸苷酶+凝固酶检测技术对250例疑似AV患者进行检测。结果在250例疑似AV患者中,镜检法检出阳性患者235例,β-葡萄糖醛酸苷酶+凝固酶检测法检出阳性患者228例。以镜检法为诊断标准,β-葡萄糖醛酸苷酶+凝固酶检测技术的敏感性为91.2%。结论β-葡萄糖醛酸苷酶+凝固酶检测技术诊断AV具有很高的敏感度和特异度,与目前临床使用的常规镜检法符合率高,且该方法操作简便、快速,值得临床推广使用。  相似文献   

18.
Pregnanetriol-3α-glucuronide (PTG) is the majority urinary metabolite of 17-hydroxyprogesterone (17OHP) and it typically increases in the commonest form of congenital adrenal hyperplasia (CAH), due to 21 hydroxylase deficiency. We developed a simple chemiluminescent immunoassay for the direct measurement of PTG in diluted urine in order to avoid the preliminary hydrolysis and extraction steps that are usually employed in gas–liquid chromatographic methods. The immunogenic complex PTG-bovine-serum-albumin was used to induce the formation of specific antibodies in New Zealand rabbits. In addition, PTG was conjugated to aminoethylethylisoluminol and the resulting tracer was characterized by mass spectrometry and used to monitor the immunological reaction. The characteristics of the antibody were determined with regard to specificity and sensitivity. The precision of the assay method was also established. PTG excretion was studied before and after the ACTH stimulation test (1 mg synthetic ACTH i.m.) in 11 normal women and in one subject affected by CAH due to 21-hydroxylase deficiency. PTG levels well correlated with 17OHP plasma concentrations both under basal and stimulated conditions, in normal women as well as in the patient affected by CAH.  相似文献   

19.
A method is described for the determination of lysozyme (muramidase) activity, whereby sensitivity is maximized by incubation of the reaction mixture (sample, buffer, and substrate (Micrococcus luteus] over an extended period. This approach is made feasible by exploiting our observation that the lytic reaction follows simple kinetic order during this time (e.g., 700 min for bovine lysozyme and 960 min for the eggwhite enzyme at low concentrations). After this period, the reaction rates diminish, indicating biphasic behavior, and eventually become negligible. The kinetic order may vary with both the type of lysozyme and the buffer system used. The limit of detection for bovine milk lysozyme is 100 pg/ml reaction mixture, equivalent to 6 ng/ml milk, for a 50-microliters sample (with reference to hen eggwhite lysozyme). With these limits, the method has proven valuable in our comparative studies, particularly for low levels of activity in bovine milk, but also in secretions and tissue extracts from various other eutherian, metatherian, and prototherian mammals. The method may also be applied to investigation of structure and function in modified forms of the enzyme.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号