1.
5-[2,4-Dioxothiazolidin-5-yl)methyl]-2-methoxy-N-[[(4-trifluoromethyl)-phenyl]methyl]benzamide (I, MK-0767 or KRP-297, Fig. 1), is a dual alpha/gamma peroxisome proliferator-activated receptor (PPAR) agonist. A LC-MS/MS method for the determination of I in human plasma has been successfully developed, validated and applied to clinical programs. The analyte and internal standard (II) are extracted from 0.05 mL plasma via solid phase extraction (SPE). HPLC is used for the separation of I and II from possible co-extracted endogenous and other compounds. Detection is by MS/MS in multiple reaction monitoring (MRM) mode using a TurboIonSpray probe. The whole sample preparation is automated by using a Packard Multiprobe liquid handling system. The linear range is 4-2000 ng/mL in plasma. Recoveries were 71.1% and 69.4% for I and II, respectively. The method exhibited good linearity, reproducibility and sensitivity, selectivity and robustness when used for the analysis of clinical samples.  相似文献   

2.
A rapid, sensitive, robust and specific method was developed for the determination and quantitation of felodipine, in human blood plasma by liquid chromatography coupled with tandem mass spectrometry using nimodipine as internal standard. Felodipine was extracted from 0.5 mL human plasma by use of a liquid/liquid procedure using diethyl ether/hexane (80/20, v/v) as eluent. The method included a chromatographic run of 5 min using a C(18) analytical column (100 mm x 4.6 mm i.d.) and the calibration curve was linear over the range from 0.02 to 10 ng mL(-1) (r(2) > 0.994). The between-run precision, determined as relative standard deviation of replicate quality controls, was 5.7% (0.06 ng mL(-1)), 7.1% (0.6 ng mL(-1)) and 6.8% (7.5 ng mL(-1)). The between-run accuracy was +/- 0.0, 2.1 and 3.1% for the above-mentioned concentrations, respectively.  相似文献   

3.
A simple and sensitive HPLC/MS/MS method was developed and evaluated to determine the concentration of ritodrine (RTD) in human plasma. Liquid-liquid extraction with ethyl acetate was employed as the sample preparation method. The structural analogue salbutamol was selected as the internal standard (IS). The liquid chromatography was performed on a Hanbon Sci. & Tech. Lichrospher CN (150 mm x 4.6 mm, i.d., 5 microm) column (Hanbon, China) at 20 degrees C. A mixture of 0.03% acetic acid and methanol (50:50, v/v) was used as isocratic mobile phase to give the retention time 3.60 min for ritodrine and 2.94 min for salbutamol. Selected reaction monitoring (SRM) in positive ionization mode was employed for mass detection. The calibration functions were linear over the concentration range 0.39-100 ng mL(-1). The intra- and inter-day precision of the method were less than 15%. The lower limit of quantification was 0.39 ng mL(-1). The method had been found to be suitable for application to a pharmacokinetic study after oral administration of 20mg ritodrine hydrochloride tablet to 18 healthy female volunteers. The half-life is 2.54+/-0.67 h.  相似文献   

4.
A rapid and sensitive liquid chromatographic/tandem mass spectrometric method for determination of misoprostol acid, the active metabolite of misoprostol, was developed and validated. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a C(18) column. An API 4000 tandem mass spectrometer equipped with Turbo IonSpray ionization source was used as detector and was operated in the negative ion mode. Multiple reaction monitoring using the precursor to product ion combinations of m/z 367-249 and 296-269 was performed to quantify misoprostol acid and the internal standard hydrochlorothiazide, respectively. The method was linear in the concentration range of 10.0-3000 pg mL(-1) using 200 microL plasma. The lower limit of quantification was 10.0 pg mL(-1). The intra- and inter-day relative standard deviation over the entire concentration range was less than 8.3%. Accuracy determined at three concentrations (25.0, 200 and 2700 pg mL(-1) for misoprostol acid) ranged from -0.5 to 1.2% in terms of relative error. Each plasma sample was chromatographed within 3.5 min. The method was successfully used in a pharmacokinetic study of misoprostol in human plasma after an oral administration of 0.6 mg misoprostol.  相似文献   

5.

Background

Activation of peroxisome proliferator-activated receptor (PPAR)gamma is associated with bone loss and increased fracture risk, while PPARalpha activation seems to have positive skeletal effects. To further explore these effects we have examined the effect of the PPARalpha agonists fenofibrate and Wyeth 14643, and the PPARgamma agonist pioglitazone, on bone mineral density (BMD), bone architecture and biomechanical strength in ovariectomized rats.

Methods

Fifty-five female Sprague-Dawley rats were assigned to five groups. One group was sham-operated and given vehicle (methylcellulose), the other groups were ovariectomized and given vehicle, fenofibrate, Wyeth 14643 and pioglitazone, respectively, daily for four months. Whole body and femoral BMD were measured by dual X-ray absorptiometry (DXA), and biomechanical testing of femurs, and micro-computed tomography (microCT) of the femoral shaft and head, were performed.

Results

Whole body and femoral BMD were significantly higher in sham controls and ovariectomized animals given fenofibrate, compared to ovariectomized controls. Ovariectomized rats given Wyeth 14643, maintained whole body BMD at sham levels, while rats on pioglitazone had lower whole body and femoral BMD, impaired bone quality and less mechanical strength compared to sham and ovariectomized controls. In contrast, cortical volume, trabecular bone volume and thickness, and endocortical volume were maintained at sham levels in rats given fenofibrate.

Conclusions

The PPARalpha agonist fenofibrate, and to a lesser extent the PPARaplha agonist Wyeth 14643, maintained BMD and bone architecture at sham levels, while the PPARgamma agonist pioglitazone exaggerated bone loss and negatively affected bone architecture, in ovariectomized rats.  相似文献   

6.
5-Azacytidine (5AC), a nucleoside analogue and hypomethylating agent, has anticancer properties and has been utilized in the treatment of various malignancies. 5AC is unstable and rapidly hydrolyzed to several by-products, including 5-azacytosine and 5-azauracil. A sensitive, reliable method was developed to quantitate 5AC using LC/MS/MS to perform pharmacokinetic and pharmacodynamic studies on 5AC combination therapy trials. Blood samples were collected in a heparinized tube and immediately processed for storage. To increase the stability of 5AC in plasma, 25 ng/mL tetrahydrouridine was added to the plasma and snap frozen. Plasma samples were extracted using acetonitrile then cleaned up by Oasis MCX ion exchange solid-phase extraction cartridges. 5AC was separated on an YMC Jsphr M80 C(18) column with gradient elution of ammonium acetate (2 mM) with 0.1% formic acid and methanol mobile phase. 5AC elutes at 5.0 +/- 0.2 min with a total run time of 30 min. Identification was through positive-ion mode and multiple reaction monitoring mode at m/z+ 244.9-->113.0 for 5AC and m/z+ 242.0-->126.0 for 5-methyl-2'-deoxycytidine, the internal standard. The lower limit of quantitation of 5AC was 5 ng/mL in human plasma, and linearity was observed from 5 to 500 ng/mL fitted by linear regression with 1/x weight. This method is 50 times more sensitive than previously published assays and successfully allows studies to characterize the pharmacokinetics and pharmacodynamics of 5AC.  相似文献   

7.
A sensitive method using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS) was developed and validated for the analysis of antihistamine drug azatadine in human plasma. Loratadine was used as internal standard (IS). Analytes were extracted from human plasma by liquid/liquid extraction using ethyl acetate. The organic phase was reduced to dryness under a stream of nitrogen at 30 °C and the residue was reconstituted with the mobile phase. 5 μL of the resulting solution was injected onto the LC-MS/MS system. A 4.6 mm × 150 mm, I.D. 5 μm, Agilent TC-C(18) column was used to perform the chromatographic analysis. The mobile phase consisted of ammonium formate buffer 0.010 M (adjusted to pH 4.3 with 1M formic acid)/acetonitrile (20:80, v/v) The chromatographic run time was 5 min per injection and flow rate was 0.6 mL/min. The retention time was 2.4 and 4.4 min for azatadine and IS, respectively. The tandem mass spectrometric detection mode was achieved with electrospray ionization (ESI) iron source and the multiple reaction monitoring (MRM) (291.3 → 248.2m/z for azatadine, 383.3 → 337.3m/z for IS) was operated in positive ion modes. The low limit of quantitation (LLOQ) was 0.05 ng/mL. The intra-day and inter-day precision of the quality control (QC) samples was 8.93-11.57% relative standard deviation (RSD). The inter-day accuracy of the QC samples was 96.83-105.07% of the nominal values.  相似文献   

8.
A rapid, sensitive and specific method for quantifying the aromatase inhibitor (anastrozole) in human plasma using dexchlorpheniramine as the internal standard (I.S.) is described herein. The analyte and the I.S. were extracted from 200 microl of human plasma by liquid-liquid extraction using a mixture of diethyl ether:dichloromethane (70:30, v/v) solution. Extracts were removed and dried in the organic phase then reconstituted with 200 microl of acetonitrile:water (50:50; v/v). The extracts were analyzed by high performance liquid chromatography coupled with photospray tandem mass spectrometry (HPLC-MS-MS). Chromatography was performed isocratically on a Genesis, C18 4 microm analytical column (100 mm x 2.1mm i.d.). The method had a chromatographic run time of 2.5 min and a linear calibration curve ranging from 0.05-10 ng ml(-1). The limit of quantification (LOQ) was 0.05 ng ml(-1). This HPLC-MS-MS procedure was used to assess pharmacokinetic studies.  相似文献   

9.
In this paper, a rapid method based on high-performance liquid chromatography/electrospray-mass spectrometry (HPLC/ESI-MS) method for the quantitative determination of andrographolide (AND) in human plasma has been developed and validated. A liquid-liquid extraction (LLE) procedure was selected to isolate AND from biological matrixes. Isosorbide-5-mononitrate (IS-5-MN) was selected as the internal standard (IS). The correlation coefficient of the calibration curve was 0.998, in the range of 9.9-320.0 ng/mL. The validated method may be used to assess the bioavailability and pharmacokinetics of the drug.  相似文献   

10.
A highly sensitive and selective HPLC-MS-MS method was developed for the determination of pramipexole in human plasma. The analytes, pramipexole and BHT-920 (internal standard), were extracted from plasma at basic pH with methyl tert.-butyl ether (MTBE). MTBE was evaporated to dryness and reconstituted in 100 μl of (95:5) methanol-water. Chromatographic separation was achieved on a Zorbax SB-CN column with a mobile phase of (15:5:80) water-0.1 M ammonium acetate—methanol. The analytes were detected utilizing HPLC in conjunction with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry (MSM). The assay was linear in the concentration ranges of 50 to 5000 pg/ml. The analysis of pooled quality controls (150, 750, and 3000 pg/ml) demonstrated excellent precision with relative standard deviations (R.S.D.) (n=18) of 7.2%, 5.3% and 5.2%, respectively. The method is accurate with all intra-day (n=6) and overall (n=18) mean values being less than 11.7% from theoretical.  相似文献   

11.
A sensitive method for the separation and determination of amlodipine enantiomers in plasma has been developed based on solid-phase extraction (SPE) with disposable extraction cartridges (DECs) in combination with chiral liquid chromatography (LC). The SPE technique is used to isolate the drug from the biological matrix and to prepare a cleaner sample before injection and analysis by HPLC coupled to mass spectrometry. The DEC is filled with ethyl silica (50 mg) and is first conditioned with a 2.5% ammonia in methanol solution and then with ammonium acetate buffer. A 1.0-ml volume of plasma is then applied on the DEC. The washing step is first performed with ammonium acetate buffer and secondly with a mixture of water and methanol (65:35, v/v), while the final elution step is obtained by dispensing methanol containing 2.5% of ammonia. The eluate is then collected and evaporated to dryness before being dissolved in the LC mobile phase and injected into the LC system. The stereoselective analysis of amlodipine is achieved on a Chiral AGP column containing alpha(1)-acid glycoprotein as chiral selector by using a mobile phase consisting of a 10-mM acetate buffer (pH 4.5) and 1-propanol (99:1, v/v). The LC system is coupled to tandem mass spectrometry with an APCI interface in the positive-ion mode. The chromatographed analytes are detected in the selected reaction monitoring mode (SRM). The MS/MS ion transitions monitored are 409 to 238 for amlodipine, and 260 to 116 for S-(-)-propranolol used as internal standard (IS). The method was validated considering different parameters, such as linearity, precision and accuracy. The limit of quantitation was found to be 0.1 ng/ml for each amlodipine enantiomer.  相似文献   

12.
13.
Pioglitazone, a thiazolidinedione (TZD) derivative, is an antidiabetic agent that improves hyperglycaemia and hyperlipidaemia in obese and diabetic animals via a reduction in hepatic and peripheral insulin resistance. The TZDs including pioglitazone have been identified as high affinity ligands for peroxisome proliferator-activated receptor (PPAR) gamma. The selectivity of pioglitazone for the human PPAR subtypes has not been reported, thus, we investigated the effect of pioglitazone on the human PPAR subtypes. Transient transactivation assay showed that pioglitazone is a selective hPPARgamma1 activator and a weak hPPARalpha activator. Binding assay indicated that the transactivation of hPPARgamma1 or hPPARalpha by pioglitazone is due to direct binding of pioglitazone to each subtype. Furthermore, pioglitazone significantly increased the apoA-I secretion from the human hepatoma cell line HepG2.  相似文献   

14.
A rapid, sensitive and selective high-performance liquid chromatography-tandem mass spectrometric method (HPLC-MS-MS) has been developed and validated for the determination of soyasaponins Ba and Bb in human serum using glycyrrhizin as internal standard (I.S.). Soyasaponins Ba and Bb were extracted from human serum by liquid-liquid extraction and cleaned up by C(18) solid-phase extraction (SPE), followed by separation on a C(18) reversed-phase column using acetonitrile/water containing 0.025% acetic acid as a mobile phase for gradient elution. Soyasaponins Ba and Bb, and I.S. were ionized by negative ion pneumatically assisted electrospray and detected by HPLC-MS-MS in the multiple-reaction monitoring (MRM) mode using precursor-->product ion combinations at m/z 958-->940, 942-->924 and 822-->351, respectively. The calibration curves were linear (r(2)>0.991) in the concentration range of 0.5-100.0 ng/mL, with lower limits of quantification of 0.5 and 0.3 ng/mL for soyasaponins Ba and Bb, respectively, in human serum. Intra-day and inter-day relative standard deviations (R.S.D.) were less than 7.9 and 11.3%, respectively. The mean recoveries of soyasaponins Ba and Bb ranged from 92 to 101% and from 85 to 94%, respectively.  相似文献   

15.
Plasma vitamin K1 (phylloquinone) determination is commonly used for the diagnosis of vitamin K deficiency in patients suffering from lipid malabsorption. Moreover, current evidence that adequate vitamin K intake, and correspondingly adequate plasma vitamin K1 concentration, could also be of importance in relation to bone and brain diseases emphasizes the need to improve the current analytical methods. We developed a liquid chromatography coupled to tandem mass spectrometry method using a stable isotope ring-D4-labeled internal standard of vitamin K1 and operating in the multiple reaction monitoring mode by the selection of a precursor and product ions. The atmospheric pressure chemical ionization (APCI) method was shown to be more sensitive than electrospray ionization. After a single-step extraction with cyclohexane, chromatographic separation was performed on a C18 column with an isocratic mobile phase. The linearity was up to 5400 ng/L, and the limit of detection was 14 ng/L. Intra- and interrun precision were 2.4% and 8.3%, respectively, for the lower limit of the reference range. Recovery was better than 98%. The method is simple and reliable, allowing accurate vitamin K1 measurement in plasma samples from healthy subjects and patients suffering from vitamin K deficiency.  相似文献   

16.
A rapid, sensitive and specific method to quantify carvedilol in human plasma using metoprolol as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using a diethyl-ether solvent. After removed and dried the organic phase, the extracts were reconstituted with a fixed volume of acetonitrile-water (50/50; v/v). The extracts were analyzed by a high performance liquid chromatography coupled to electrospray tandem mass spectrometry (HPLC-MS/MS). Chromatography was performed isocratically on Alltech Prevail C18 5 microm analytical column, (150 mm x 4.6 mm i.d.). The method had a chromatographic run time of 3.5 min and a linear calibration curve over the range 0.1-200 ng ml(-1) (r2>0.997992). The limit of quantification was 0.1 ng ml(-1). This HPLC-MS/MS procedure was used to assess the bioequivalence of two carvedilol 25 mg tablet formulations (carvedilol test formulation from Laboratórios Biosintética Ltda and Coreg from Roche Químicos e Farmacêuticos S.A standard reference formulation). A single 25 mg dose of each formulation was administered to healthy volunteers. The study was conducted using an open, randomized, two-period crossover design with a 2-week wash-out interval. Since the 90% CI for C(max) and AUCs ratios were all inside the 80-125% interval proposed by the US Food and Drug Administration Agency, it was concluded that carvedilol formulation elaborated by Laboratórios Biosintética Ltda is bioequivalent to Coreg formulation for both the rate and the extent of absorption.  相似文献   

17.
Sugammadex (Bridion?, Merck Sharp & Dohme Corp., Oss, The Netherlands) is a modified γ-cyclodextrin which has the ability to reverse the neuromuscular blockade induced by the steroidal neuromuscular blocking agents rocuronium and vecuronium. The objective of the current study is to describe the bioanalytical methods that have been developed and validated according to US Food and Drug Administration guidelines on bioanalytical method validation, and subsequently applied to determine total sugammadex (i.e., free sugammadex plus sugammadex bound to the neuromuscular blocking agent) in human heparinized plasma, urine and dialysate. Sugammadex was extracted from human plasma and urine using solid phase extraction with Isolute HAX 96-well extraction plates; no extraction was performed on dialysate samples. Samples from plasma, urine, and dialysate were analyzed on a Polaris? C18-A PEEK (polyaryletheretherketone) analytical column (50 mm × 4.6 mm internal diameter, 5 μm) with a linear mobile phase gradient of 0.1% (v/v) formic acid in water:methanol from 70:30 to 20:80. The flow rate was 1 mL/min with a total run time for each injection of 6 min. Tandem mass spectrometric detection was conducted using multiple reaction monitoring under negative ion mode with a turbo ion-spray interface to quantify the concentration of sugammadex. Inter- and intra-assay precision and accuracy were within pre-defined acceptance limits. The presence of rocuronium did not interfere with the assay in plasma, urine or dialysate; similarly, vecuronium did not interfere with the plasma assay (not tested for interference in urine or dialysate). Sugammadex was found to be stable in plasma, urine and dialysate in the short-term at room temperature, in the long-term at -20°C, and after several freeze/thaw cycles. The validated bioanalytical methods developed here have been successfully applied in a series of clinical studies for the determination of total sugammadex in plasma, urine and dialysate.  相似文献   

18.
The major urinary metabolite of selenium (Se) in rats was identified by HPLC-inductively coupled argon plasma mass spectrometry (ICP-MS) and--electrospray tandem mass spectrometry (ESI-MS/MS). As the urine sample was rich in matrices such as sodium chloride and urea, it was partially purified to meet the requirements for ESI-MS. The group of signals corresponding to the Se isotope ratio was detected in both the positive and negative ion modes at m/z 300 ([M+H]+) and 358 ([M+CH3COO]-) for 80Se, respectively. These results suggested that the molecular mass of the Se metabolite was 299 Da for 80Se. The Se metabolite was deduced to contain one methylselenyl group, one acetyl group and at least two hydroxyl groups from the mass spectra of the fragment ions. The spectrum of the Se metabolite was completely identical to that of the synthetic selenosugar, 2-acetamide-1,2-dideoxy-beta-D-glucopyranosyl methylselenide. However, the chromatographic behavior of the Se metabolite was slightly different from that of the synthetic selenosugar. Thus, the major urinary Se metabolite was assigned as a diastereomer of a selenosugar, Se-methyl-N-acetyl-selenohexosamine.  相似文献   

19.
With the growing interest for peptides and proteins in different kinds of fields, e.g. pharmacy, clinical diagnostics or food industry, the quantification of these compounds is becoming more and more important. Quantitative analysis of these analytes in biological matrices, however, remains a challenging task, due to the complexity of both the matrix and the analytical characteristics of these large bio-molecules. Liquid chromatography coupled to (tandem) mass spectrometry (LC-MS or LC-MS/MS) is the preferred analytical technique for peptide analysis as it allows very selective and sensitive measurements. This article summarizes the numerous published LC-MS applications for the quantification of peptides in biological matrices and discusses all different issues herewith concerned. This includes chromatographic aspects as the selection and effects of mobile and stationary phase, flow rate and temperature, as well as mass spectrometric characteristics such as ionization and detection modes, collision-induced dissociation of peptides and factors influencing the mass spectrometric response. For both techniques the main properties of all described methods have been listed, creating a comprehensive overview with the peptide analytes divided into different classes. Likewise, all other issues concerned with quantitative bioanalysis have been evaluated in detail, including extensive consideration of several different applied sample pre-treatment techniques and reflection of subjects as the choice for an internal standard and assay validation. Furthermore, several issues which are of particular interest for the quantitative bioanalysis of peptide compounds like peptide adsorption and degradation have been regarded.  相似文献   

20.
A simple, rapid and sensitive liquid chromatography/tandem mass spectrometric (LC/MS/MS) analytical method was developed for quantification of Hsp90 inhibitor PF-04928473 in human plasma, following administration of its prodrug, PF-04929113. Sample processing involved protein precipitation by addition of 0.4 mL of methanol containing internal standard (PF-04972487) to 50 μL volume of plasma sample. Chromatographic separation of PF-04928473 and PF-04972487 was achieved on a Phenomenex® Luna C18(2) (2.0mm × 50 mm, 5 μm) column using a gradient elution method with mobile phase solvents: methanol containing 0.1% formic acid and 0.1% formic acid at a flow rate of 0.25 mL/min. Detection was performed in electrospray positive ionization mode, monitoring the ion transitions from m/z 465.1 → 350.1 (PF-04928473) and m/z 447.0 → 329.1 (PF-04972487). The retention times for PF-04928473 and PF-04972487 were 1.86 and 2.85 min, respectively. Calibration curves were generated in the range of 2–2000 ng/mL. The accuracy and precision ranged from 94.1 to 99.0% and 86.7 to 97.6%, respectively, which were calculated using quality control samples of three different concentrations analyzed in quintuplicate on four different days.  相似文献   