首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
The downward migration through soil of seeded poliovirus type 1 and echovirus type 1 and of naturally occurring enteroviruses during infiltration of sewage effluent through rapid-infiltration basins was investigated. After 5 days of flooding, the amount of seeded poliovirus type 1 that had migrated 5 to 10 cm downward through the soil profile was found to be 11% of that remaining at the initial burial depth. The amount of echovirus type 1 determined to have moved an equal distance was at least 100-fold less. Migration of naturally occurring enteroviruses during infiltration of sewage effluent through soil could not be measured with accuracy because of the possibility of virus survival from previous applications of effluent. The rate of inactivation for seeded poliovirus 1 and echovirus 1 buried in the infiltration basins ranged between 0.04 and 0.15 log10 units per day during the time when the basins were flooded. Inactivation of these same seeded virus types and of indigenous enterovirus populations in the infiltration basins during the drying portion of the sewage application cycle ranged between 0.11 and 0.52 log10 units per day. The rate of virus inactivation was dependent upon the rate of soil moisture loss. These results indicate that drying cycles during the land application of wastewater enhance virus inactivation in the soil.  相似文献   

2.
Chlorination of indicator bacteria and viruses in primary sewage effluent   总被引:3,自引:0,他引:3  
Wastewater disinfection is used in many countries for reducing fecal coliform levels in effluents. Disinfection is therefore frequently used to improve recreational bathing waters which do not comply with microbiological standards. It is unknown whether human enteric viruses (which are responsible for waterborne disease) are simultaneously inactivated alongside fecal coliforms. This laboratory study focused on the chlorination of primary treated effluent with three doses (8, 16, and 30 mg/liter) of free chlorine as sodium hypochlorite. Seeding experiments showed that inactivation (>5 log(10) units) of Escherichia coli and Enterococcus faecalis was rapid and complete but that there was poor inactivation (0.2 to 1.0 log(10) unit) of F(+)-specific RNA (FRNA) bacteriophage (MS2) (a potential virus indicator) at all three doses. However, seeded poliovirus was significantly more susceptible (2.8 log(10) units) to inactivation by chlorine than was the FRNA bacteriophage. To ensure that these results were not artifacts of the seeding process, comparisons were made between inactivation rates of laboratory-seeded organisms in sterilized sewage and inactivation rates of organisms occurring naturally in sewage. Multifactorial analysis of variance showed that there was no significant difference (P > 0.05) between the inactivation rates for seeded and naturally occurring FRNA bacteriophage. However, laboratory-grown poliovirus was inactivated much more rapidly than were naturally occurring, indigenous enteroviruses (P < 0.001). This may reflect differences in the way indigenous virus is presented to the disinfectant. Inactivation rates for indigenous enteroviruses were quite similar to those seen for FRNA bacteriophage at lower doses of chlorine. These results have significance for the effectiveness of chlorination as a sewage treatment process, particularly where virus contamination is of concern, and suggest that FRNA bacteriophage would be an appropriate indicator of such viral inactivation under field conditions.  相似文献   

3.
Effect of soil permeability on virus removal through soil columns.   总被引:2,自引:2,他引:0       下载免费PDF全文
Laboratory experiments were performed on four different soils, using 100 cm long columns, to determine the extent of virus movement when wastewater percolated through the soils at various hydraulic flow rates. Unchlorinated secondary sewage effluent seeded with either poliovirus type 1 (strain LSc) or echovirus type 1 (isolate V239) was continuously applied to soil columns for 3 to 4 days at constant flow rates. Water samples were extracted daily from ceramic samplers at various depths of the column for the virus assay. The effectiveness of virus removal from wastewater varied greatly among the different soil types but appeared to be largely related to hydraulic flow rates. At a flow rate of 33 cm/day, Anthony sandy loam removed 99% of seeded poliovirus within the first 7 cm of the column. At flow rates of 300 cm/day and above, Rubicon sand gave the poorest removal of viruses; less than 90% of the seeded viruses were removed by passage of effluent through the entire length of the soil column. By linear regression analyses, the rate of virus removal in soil columns was found to be negatively correlated with the flow of the percolating sewage effluent. There was no significant difference in rate of removal between poliovirus and echovirus in soil columns 87 cm long. The rate of virus removal in the upper 17 cm of the soil column was found to be significantly greater than in the lower depths of the soil column. This study suggests that the flow rate of water through the soil may be the most important factor in predicting the potential of virus movement into the groundwater. Furthermore, the length of the soil column is critical in obtaining useful data to predict virus movement into groundwater.  相似文献   

4.
Laboratory experiments were performed on four different soils, using 100 cm long columns, to determine the extent of virus movement when wastewater percolated through the soils at various hydraulic flow rates. Unchlorinated secondary sewage effluent seeded with either poliovirus type 1 (strain LSc) or echovirus type 1 (isolate V239) was continuously applied to soil columns for 3 to 4 days at constant flow rates. Water samples were extracted daily from ceramic samplers at various depths of the column for the virus assay. The effectiveness of virus removal from wastewater varied greatly among the different soil types but appeared to be largely related to hydraulic flow rates. At a flow rate of 33 cm/day, Anthony sandy loam removed 99% of seeded poliovirus within the first 7 cm of the column. At flow rates of 300 cm/day and above, Rubicon sand gave the poorest removal of viruses; less than 90% of the seeded viruses were removed by passage of effluent through the entire length of the soil column. By linear regression analyses, the rate of virus removal in soil columns was found to be negatively correlated with the flow of the percolating sewage effluent. There was no significant difference in rate of removal between poliovirus and echovirus in soil columns 87 cm long. The rate of virus removal in the upper 17 cm of the soil column was found to be significantly greater than in the lower depths of the soil column. This study suggests that the flow rate of water through the soil may be the most important factor in predicting the potential of virus movement into the groundwater. Furthermore, the length of the soil column is critical in obtaining useful data to predict virus movement into groundwater.  相似文献   

5.
Wastewater disinfection is used in many countries for reducing fecal coliform levels in effluents. Disinfection is therefore frequently used to improve recreational bathing waters which do not comply with microbiological standards. It is unknown whether human enteric viruses (which are responsible for waterborne disease) are simultaneously inactivated alongside fecal coliforms. This laboratory study focused on the chlorination of primary treated effluent with three doses (8, 16, and 30 mg/liter) of free chlorine as sodium hypochlorite. Seeding experiments showed that inactivation (>5 log10 units) of Escherichia coli and Enterococcus faecalis was rapid and complete but that there was poor inactivation (0.2 to 1.0 log10 unit) of F+-specific RNA (FRNA) bacteriophage (MS2) (a potential virus indicator) at all three doses. However, seeded poliovirus was significantly more susceptible (2.8 log10 units) to inactivation by chlorine than was the FRNA bacteriophage. To ensure that these results were not artifacts of the seeding process, comparisons were made between inactivation rates of laboratory-seeded organisms in sterilized sewage and inactivation rates of organisms occurring naturally in sewage. Multifactorial analysis of variance showed that there was no significant difference (P > 0.05) between the inactivation rates for seeded and naturally occurring FRNA bacteriophage. However, laboratory-grown poliovirus was inactivated much more rapidly than were naturally occurring, indigenous enteroviruses (P < 0.001). This may reflect differences in the way indigenous virus is presented to the disinfectant. Inactivation rates for indigenous enteroviruses were quite similar to those seen for FRNA bacteriophage at lower doses of chlorine. These results have significance for the effectiveness of chlorination as a sewage treatment process, particularly where virus contamination is of concern, and suggest that FRNA bacteriophage would be an appropriate indicator of such viral inactivation under field conditions.  相似文献   

6.
The adsorption and elution of a variety of human enteroviruses in a highly permeable, sandy soil was studied by using cores (43 by 125 mm) collected from an operating recharge basin on Long Island. Viruses studied included field and reference strains of polioviruses types 1 and 3 and reference strains of coxsackie virus B3 and echovirus types 1 and 6. Viruses suspended in treated sewage effluent were allowed to percolate through soil cores, and the filtrate was assayed for unadsorbed viruses. To determine the likelihood of desorption and mobilization, soil-bound viruses were subjected to a rinse with either treated sewage effluent or simulated rainwater which reflected the anion, cation, and pH characteristics of a typical northeastern United States rainfall. The results demonstrated that all polioviruses tested, including both reference and field strains, adsorbed extremely well to cores. Adsorption was somewhat reduced when clean, unconditioned soils were used. Soil-bound poliovirus strain LSc was not significantly mobilized by flooding columns with either a sewage effluent or rainwater rinse. One virus was mobilized by both types of rinses. The amount of viruses mobilized by rainwater rinses ranged from 24 to 66%. Variable adsorption-elution results were observed with other enteroviruses. Two guanidine-resistant mutants of poliovirus LSc demonstrated a soil adsorption-elution profile different from that of the parent strain. The data support the conclusion that soil adsorption-elution behavior is strain dependent and that poliovirus, particularly strain LSc, represents an inappropriate model.  相似文献   

7.
The adsorption and elution of a variety of human enteroviruses in a highly permeable, sandy soil was studied by using cores (43 by 125 mm) collected from an operating recharge basin on Long Island. Viruses studied included field and reference strains of polioviruses types 1 and 3 and reference strains of coxsackie virus B3 and echovirus types 1 and 6. Viruses suspended in treated sewage effluent were allowed to percolate through soil cores, and the filtrate was assayed for unadsorbed viruses. To determine the likelihood of desorption and mobilization, soil-bound viruses were subjected to a rinse with either treated sewage effluent or simulated rainwater which reflected the anion, cation, and pH characteristics of a typical northeastern United States rainfall. The results demonstrated that all polioviruses tested, including both reference and field strains, adsorbed extremely well to cores. Adsorption was somewhat reduced when clean, unconditioned soils were used. Soil-bound poliovirus strain LSc was not significantly mobilized by flooding columns with either a sewage effluent or rainwater rinse. One virus was mobilized by both types of rinses. The amount of viruses mobilized by rainwater rinses ranged from 24 to 66%. Variable adsorption-elution results were observed with other enteroviruses. Two guanidine-resistant mutants of poliovirus LSc demonstrated a soil adsorption-elution profile different from that of the parent strain. The data support the conclusion that soil adsorption-elution behavior is strain dependent and that poliovirus, particularly strain LSc, represents an inappropriate model.  相似文献   

8.
Seasonal distribution of enteroviruses and adenoviruses in domestic sewage   总被引:3,自引:0,他引:3  
A seasonal distribution of enteroviruses and adenoviruses in raw sewage effluents of Athens, Greece, was observed over a 15-month surveillance period. All 36 samples tested were positive for both virus groups. Adenovirus concentration levels ranged from 70 to 3200 cytopathic units per litre of sample, whereas the corresponding values for enteroviruses were 90-900 cytopathic units per litre. Peak values for adenoviruses were recorded during the months of April and June 1983, whereas for enteroviruses the peak was recorded in September 1983. All three types of poliovirus were present. Coxsackievirus types B-1, B-2, B-4, and B-5 and echovirus type 7 were also isolated. Adenovirus types 1, 2, 3, 5, 7, and 15 were detected as well.  相似文献   

9.
The development and evaluation of methods for the quantitative recovery of enteroviruses from sewage sludge are reported. Activated sewage sludge solids were collected by centrifugation, and elution of the solid-associated virus was accomplished by mechanical agitation in glycine buffer at pH 11.0. Eluted viruses were concentrated either onto an aluminum hydroxide floc or by association with a floc which formed de novo upon adjustment of the glycine eluate to pH 3.5. Viruses which remained in the liquid phase after lowering the pH of glycine eluate were concentrated by adsorption to and elution from membrane filters. The method of choice included high pH glycine elution and subsequent low pH concentration; it yielded an efficiency of recovery from activated sludge of 80% for poliovirus type 1, 68% for echovirus type 7, and 75% for coxsackievirus B3. This method was used to study the survival of naturally occurring virus in sludge at a sewage treatment plant and after subsequent land disposal of the solids after aerobic digestion. Reduction of enterovirus titers per gram (dry weight) of solids were modest during sludge activation but increased to a rate of 2 log 10/week after land disposal.  相似文献   

10.
The development and evaluation of methods for the quantitative recovery of enteroviruses from sewage sludge are reported. Activated sewage sludge solids were collected by centrifugation, and elution of the solid-associated virus was accomplished by mechanical agitation in glycine buffer at pH 11.0. Eluted viruses were concentrated either onto an aluminum hydroxide floc or by association with a floc which formed de novo upon adjustment of the glycine eluate to pH 3.5. Viruses which remained in the liquid phase after lowering the pH of glycine eluate were concentrated by adsorption to and elution from membrane filters. The method of choice included high pH glycine elution and subsequent low pH concentration; it yielded an efficiency of recovery from activated sludge of 80% for poliovirus type 1, 68% for echovirus type 7, and 75% for coxsackievirus B3. This method was used to study the survival of naturally occurring virus in sludge at a sewage treatment plant and after subsequent land disposal of the solids after aerobic digestion. Reduction of enterovirus titers per gram (dry weight) of solids were modest during sludge activation but increased to a rate of 2 log 10/week after land disposal.  相似文献   

11.
Adsorption of poliovirus from primary sewage effluent was similar to that from secondary sewage effluent in both batch soil studies and experiments with soil columns 240 cm long. Virus desorption by distilled water was also similar in a soil column that had been flooded with either primary or secondary effluent seeded with virus. These results indicated that absorption of poliovirus from primary effluent and virus movement through the soil were not affected by the higher organic content of primary sewage effluent.  相似文献   

12.
Adsorption of poliovirus from primary sewage effluent was similar to that from secondary sewage effluent in both batch soil studies and experiments with soil columns 240 cm long. Virus desorption by distilled water was also similar in a soil column that had been flooded with either primary or secondary effluent seeded with virus. These results indicated that absorption of poliovirus from primary effluent and virus movement through the soil were not affected by the higher organic content of primary sewage effluent.  相似文献   

13.
Because of the increasing emphasis placed upon land application as a means of wastewater disposal, it is important to evaluate the influences of different factors upon virus survival in soil. The objective of this study was to measure the effects of various environmental variables on virus persistence. Test samples of soil were placed in vials, and the soil was wetted with suspensions of virus in either distilled water, unchlorinated secondary sewage effluent, or mixtures of effluent and water. The viruses used were coxsackieviruses A9 and B3, echovirus 1, poliovirus 2, rotavirus SA11, and bacteriophages T2 and MS2. The rate of virus inactivation was evaluated statistically with regard to conditions under which the vials were incubated and to the soil characteristics. The factors that were found to influence virus survival were temperature, soil moisture content, presence of aerobic microorganisms, degree of virus adsorption to the soil, soil levels of resin-extractable phosphorus, exchangeable aluminium, and soil pH. Overall, temperature and virus adsorption to soil appeared to be the most important factors affecting virus survival.  相似文献   

14.
C J Hurst  C P Gerba    I Cech 《Applied microbiology》1980,40(6):1067-1079
Because of the increasing emphasis placed upon land application as a means of wastewater disposal, it is important to evaluate the influences of different factors upon virus survival in soil. The objective of this study was to measure the effects of various environmental variables on virus persistence. Test samples of soil were placed in vials, and the soil was wetted with suspensions of virus in either distilled water, unchlorinated secondary sewage effluent, or mixtures of effluent and water. The viruses used were coxsackieviruses A9 and B3, echovirus 1, poliovirus 2, rotavirus SA11, and bacteriophages T2 and MS2. The rate of virus inactivation was evaluated statistically with regard to conditions under which the vials were incubated and to the soil characteristics. The factors that were found to influence virus survival were temperature, soil moisture content, presence of aerobic microorganisms, degree of virus adsorption to the soil, soil levels of resin-extractable phosphorus, exchangeable aluminium, and soil pH. Overall, temperature and virus adsorption to soil appeared to be the most important factors affecting virus survival.  相似文献   

15.
A survey of enteric viruses in domestic sewage   总被引:6,自引:0,他引:6  
In this second study (1979-1981) of the viral content of sewage we have demonstrated the presence of poliovirus types 1, 2, and 3 in Laval and Montreal. Several strains of poliovirus types 2 and 3 were nonvaccinal. This is in contrast with our first study (1977-1978) in which only type 1 poliovirus isolates were nonvaccinal. Coxsackievirus types B-3, B-4, and B-5 and echovirus types 1, 7, and 11 were also isolated from sewage. Interestingly, these isolations coincided with reports of isolation of the same strains during the same period by diagnostic laboratories. Our method based on Vero and BSC-1 cell cultures for virus isolation and immune electron microscopy for identification permitted the recovery not only of several strains of enteroviruses but also of some adenoviruses and reoviruses.  相似文献   

16.
This study was designed to determine the degree of adsorption of enteric viruses to marine sediment and factors controlling this association. Adsorption and elution characteristics of several enteroviruses and one rotavirus to estuarine sediments were studied under varying conditions of pH, salinity, and presence of soluble organics. Greater than 99% of the added poliovirus type 1 (LSc), coxsackievirus type B3 (Nancy), echovirus type 7 (Wallace), and rotavirus (SA-11) adsorbed to sediment. Echovirus 1 (Farouk) and a recent isolate typed as coxsackievirus B4 adsorbed significantly less than poliovirus 1 under similar conditions of varying salinity and pH. The presence of soluble organic matter, in the form of secondary sewage effluent or humic acid, did not affect these patterns of adsorption. Only echovirus 1 (Farouk) desorbed when the pH or salinity was altered and then only to a small extent. Three recent isolates of echovirus 1 and echovirus 29 (strain JV-10) also demonstrated varying amounts of adsorption to sediment. These data indicate that enteric viruses can become readily associated with sediment in the estuarine environment and that this association may play a major role in their hydrotransportation and survival.  相似文献   

17.
Virus movement in soil during saturated and unsaturated flow   总被引:3,自引:0,他引:3  
Virus movement in soil during saturated and unsaturated flow was compared by adding poliovirus to sewage water and applying the water at different rates to a 250-cm-long soil column equipped with ceramic samplers at different depths. Movement of viruses during unsaturated flow of sewage through soil columns was much less than during saturated flow. Viruses did not move below the 40-cm level when sewage water was applied at less than the maximum infiltration rate; virus penetration in columns flooded with sewage was at least 160 cm. Therefore, virus movement in soils irrigated with sewage should be less than in flooded groundwater recharge basins or in saturated soil columns. Management of land treatment systems to provide unsaturated flow through the soil should minimize the depth of virus penetration. Differences in virus movement during saturated and unsaturated flow must be considered in the development of any model used to simulate virus movement in soils.  相似文献   

18.
Virus movement in soil during saturated and unsaturated flow.   总被引:7,自引:3,他引:4       下载免费PDF全文
Virus movement in soil during saturated and unsaturated flow was compared by adding poliovirus to sewage water and applying the water at different rates to a 250-cm-long soil column equipped with ceramic samplers at different depths. Movement of viruses during unsaturated flow of sewage through soil columns was much less than during saturated flow. Viruses did not move below the 40-cm level when sewage water was applied at less than the maximum infiltration rate; virus penetration in columns flooded with sewage was at least 160 cm. Therefore, virus movement in soils irrigated with sewage should be less than in flooded groundwater recharge basins or in saturated soil columns. Management of land treatment systems to provide unsaturated flow through the soil should minimize the depth of virus penetration. Differences in virus movement during saturated and unsaturated flow must be considered in the development of any model used to simulate virus movement in soils.  相似文献   

19.
Secondary sewage effluent containing about 3 X 10(4) plaque-forming units of polio virus type 1 (LSc) per ml was passed through columns 250 cm in length packed with calcareous sand from an area in the Salt River bed used for ground-water recharge of secondary sewage effluent. Viruses were not detected in 1-ml samples extracted from the columns below the 160-cm level. However, viruses were detected in 5 of 43 100-ml samples of the column drainage water. Most of the viruses were adsorbed in the top 5 cm of soil. Virus removal was not affected by the infiltration rate, which varied between 15 and 55 cm/day. Flooding a column continuosly for 27 days with the sewage water virus mixture did not saturate the top few centimeters of soil with viruses and did not seem to affect virus movement. Flooding with deionized water caused virus desorption from the soil and increased their movement through the columns. Adding CaCl2 to the deionized water prevented most of the virus desorption. Adding a pulse of deionized water followed by sewage water started a virus front moving through the columns, but the viruses were readsorbed and none was detected in outflow samples. Drying the soil for 1 day between applying the virus and flooding with deionized water greatly reduced desorption, and drying for 5 days prevented desorption. Large reductions (99.99% or more) of virus would be expected after passage of secondary sewage effluent through 250 cm of the calcareous sand similar to that used in our laboratory columns unless heavy rains fell within 1 day after the application of sewage stopped. Such virus movement could be minimized by the proper management of flooding and drying cycles.  相似文献   

20.
Virus movement in soil columns flooded with secondary sewage effluent.   总被引:13,自引:13,他引:0       下载免费PDF全文
Secondary sewage effluent containing about 3 X 10(4) plaque-forming units of polio virus type 1 (LSc) per ml was passed through columns 250 cm in length packed with calcareous sand from an area in the Salt River bed used for ground-water recharge of secondary sewage effluent. Viruses were not detected in 1-ml samples extracted from the columns below the 160-cm level. However, viruses were detected in 5 of 43 100-ml samples of the column drainage water. Most of the viruses were adsorbed in the top 5 cm of soil. Virus removal was not affected by the infiltration rate, which varied between 15 and 55 cm/day. Flooding a column continuosly for 27 days with the sewage water virus mixture did not saturate the top few centimeters of soil with viruses and did not seem to affect virus movement. Flooding with deionized water caused virus desorption from the soil and increased their movement through the columns. Adding CaCl2 to the deionized water prevented most of the virus desorption. Adding a pulse of deionized water followed by sewage water started a virus front moving through the columns, but the viruses were readsorbed and none was detected in outflow samples. Drying the soil for 1 day between applying the virus and flooding with deionized water greatly reduced desorption, and drying for 5 days prevented desorption. Large reductions (99.99% or more) of virus would be expected after passage of secondary sewage effluent through 250 cm of the calcareous sand similar to that used in our laboratory columns unless heavy rains fell within 1 day after the application of sewage stopped. Such virus movement could be minimized by the proper management of flooding and drying cycles.  相似文献   