首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 29 毫秒
1.
Many patients with Chagas disease live in remote communities that lack both equipment and trained personnel to perform a diagnosis by conventional serology (CS). Thus, reliable tests suitable for use under difficult conditions are required. In this study, we evaluated the ability of personnel with and without laboratory skills to perform immunochromatographic (IC) tests to detect Chagas disease at a primary health care centre (PHCC). We examined whole blood samples from 241 patients and serum samples from 238 patients. Then, we calculated the percentage of overall agreement (POA) between the two groups of operators for the sensitivity (S), specificity (Sp) and positive (PPV) and negative (NPV) predictive values of IC tests compared to CS tests. We also evaluated the level of agreement between ELISAs and indirect haemagglutination (IHA) tests. The readings of the IC test results showed 100% agreement (POA = 1). The IC test on whole blood showed the following values: S = 87.3%; Sp = 98.8%; PPV = 96.9% and NPV = 95.9%. Additionally, the IC test on serum displayed the following results: S = 95.7%; Sp = 100%; PPV = 100% and NPV = 98.2%. Using whole blood, the agreement with ELISA was 96.3% and the agreement with IHA was 94.1%. Using serum, the agreement with ELISA was 97.8% and the agreement with IHA was 96.6%. The IC test performance with serum samples was excellent and demonstrated its usefulness in a PHCC with minimal equipment. If the IC test S value and NPV with whole blood are improved, then this test could also be used in areas lacking laboratories or specialised personnel.  相似文献   

2.
Approximately 250,000 immigrants from Latin America live in Japan and it is estimated that 1500–3000 of them are potentially infected with Trypanosoma cruzi, the cause of Chagas disease. Therefore, the establishment of a standardized diagnostic method for Chagas disease in Japan is urgently needed. In this study, we optimized and evaluated the ARCHITECT Chagas assay and in-house ELISA for Chagas disease in clinical settings. In particular, we evaluated the performance of ARCHITECT Chagas as well as ELISA with whole-cell lysates and three recombinant proteins (TcF, TcBCDE, and CP1 + CP3) using 93 Chagas disease-positive serum samples and 108 Chagas disease-positive samples. The sensitivities of ARCHITECT Chagas, whole-cell lysate, TcF, TcBCDE, and CP1 + CP3 ELISA were respectively 100%, 100%, 98.9%, 98.9%, and 89.2% and the corresponding specificities were 100%, 99.1%, 99.1%, 100%, and 99.1%. False-positive results were obtained for whole-cell lysate, TcF, and CP1 ± CP3 ELISA. This is the first evidence that OD cut-off values optimized for in-house ELISA are similar in terms of sensitivity and specificity to those of the ARCHITECT Chagas test, supporting the use of these in-house assays as diagnostic tests for Chagas disease in the clinical setting in Japan.  相似文献   

3.
Orally transmitted Chagas disease has become a matter of concern due to outbreaks reported in four Latin American countries. Although several mechanisms for orally transmitted Chagas disease transmission have been proposed, food and beverages contaminated with whole infected triatomines or their faeces, which contain metacyclic trypomastigotes of Trypanosoma cruzi, seems to be the primary vehicle. In 2007, the first recognised outbreak of orally transmitted Chagas disease occurred in Venezuela and largest recorded outbreak at that time. Since then, 10 outbreaks (four in Caracas) with 249 cases (73.5% children) and 4% mortality have occurred. The absence of contact with the vector and of traditional cutaneous and Romana’s signs, together with a florid spectrum of clinical manifestations during the acute phase, confuse the diagnosis of orally transmitted Chagas disease with other infectious diseases. The simultaneous detection of IgG and IgM by ELISA and the search for parasites in all individuals at risk have been valuable diagnostic tools for detecting acute cases. Follow-up studies regarding the microepidemics primarily affecting children has resulted in 70% infection persistence six years after anti-parasitic treatment. Panstrongylus geniculatus has been the incriminating vector in most cases. As a food-borne disease, this entity requires epidemiological, clinical, diagnostic and therapeutic approaches that differ from those approaches used for traditional direct or cutaneous vector transmission.  相似文献   

4.

Background

PCR has evolved into one of the most promising tools for T. cruzi detection in the diagnosis and control of Chagas disease. However, general use of the technique is hampered by its complexity and the lack of standardization.

Methodology

We here present the development and phase I evaluation of the T. cruzi OligoC-TesT, a simple and standardized dipstick format for detection of PCR amplified T. cruzi DNA. The specificity and sensitivity of the assay were evaluated on blood samples from 60 Chagas non-endemic and 48 endemic control persons and on biological samples from 33 patients, 7 reservoir animals, and 14 vectors collected in Chile.

Principal Findings

The lower detection limits of the T. cruzi OligoC-TesT were 1 pg and 1 to 10 fg of DNA from T. cruzi lineage I and II, respectively. The test showed a specificity of 100% (95% confidence interval [CI]: 96.6%–100%) on the control samples and a sensitivity of 93.9% (95% CI: 80.4%–98.3%), 100% (95% CI: 64.6%–100%), and 100% (95% CI: 78.5%–100%) on the human, rodent, and vector samples, respectively.

Conclusions

The T. cruzi OligoC-TesT showed high sensitivity and specificity on a diverse panel of biological samples. The new tool is an important step towards simplified and standardized molecular diagnosis of Chagas disease.  相似文献   

5.
In Brazil, human and canine visceral leishmaniasis (CVL) caused byLeishmania infantum has undergone urbanisation since 1980, constituting a public health problem, and serological tests are tools of choice for identifying infected dogs. Until recently, the Brazilian zoonoses control program recommended enzyme-linked immunosorbent assays (ELISA) and indirect immunofluorescence assays (IFA) as the screening and confirmatory methods, respectively, for the detection of canine infection. The purpose of this study was to estimate the accuracy of ELISA and IFA in parallel or serial combinations. The reference standard comprised the results of direct visualisation of parasites in histological sections, immunohistochemical test, or isolation of the parasite in culture. Samples from 98 cases and 1,327 noncases were included. Individually, both tests presented sensitivity of 91.8% and 90.8%, and specificity of 83.4 and 53.4%, for the ELISA and IFA, respectively. When tests were used in parallel combination, sensitivity attained 99.2%, while specificity dropped to 44.8%. When used in serial combination (ELISA followed by IFA), decreased sensitivity (83.3%) and increased specificity (92.5%) were observed. Serial testing approach improved specificity with moderate loss in sensitivity. This strategy could partially fulfill the needs of public health and dog owners for a more accurate diagnosis of CVL.  相似文献   

6.
BackgroundThe diagnosis of Chagas disease is complex due to the dynamics of parasitemia in the clinical phases of the disease. The molecular tests have been considered promissory because they detect the parasite in all clinical phases. Trypanosoma cruzi presents significant genetic variability and is classified into six Discrete Typing Units TcI-TcVI (DTUs) with the emergence of foreseen genotypes within TcI as TcIDom and TcI Sylvatic. The objective of this study was to determine the operating characteristics of molecular tests (conventional and Real Time PCR) for the detection of T. cruzi DNA, parasitic loads and DTUs in a large cohort of Colombian patients from acute and chronic phases.Conclusions/SignificanceThe molecular tests are a precise tool to complement the standard diagnosis of Chagas disease, specifically in acute phase showing high discriminative power. However, it is necessary to improve the sensitivity of molecular tests in chronic phase. The frequency and parasitemia of TcIDom genotype in chronic patients highlight its possible relationship to the chronicity of the disease.  相似文献   

7.
The protozoan Trypanosoma cruzi is the etiologic agent of Chagas disease, an infection that afflicts approximately 8 million people in Latin America. Diagnosis of chronic Chagas disease is currently based on serological tests because this condition is usually characterized by high anti-T. cruzi IgG titers and low parasitemia. The antigens used in these assays may have low specificity due to cross reactivity with antigens from related parasite infections, such as leishmaniasis, and low sensitivity caused by the high polymorphism among T. cruzi strains. Therefore, the identification of new T. cruzi-specific antigens that are conserved among the various parasite discrete typing units (DTUs) is still required. In the present study, we have explored the hybrid nature of the T. cruzi CL Brener strain using a broad genome screening approach to select new T. cruzi antigens that are conserved among the different parasite DTUs and that are absent in other trypanosomatid species. Peptide arrays containing the conserved antigens with the highest epitope prediction scores were synthesized, and the reactivity of the peptides were tested by immunoblot using sera from C57BL/6 mice chronically infected with T. cruzi strains from the TcI, TcII or TcVI DTU. The two T. cruzi proteins that contained the most promising peptides were expressed as recombinant proteins and tested in ELISA experiments with sera from chagasic patients with distinct clinical manifestations: those infected with T. cruzi from different DTUs and those with cutaneous or visceral leishmaniasis. These proteins, named rTc_11623.20 and rTc_N_10421.310, exhibited 94.83 and 89.66% sensitivity, 98.2 and 94.6% specificity, respectively, and a pool of these 2 proteins exhibited 96.55% sensitivity and 98.18% specificity. This work led to the identification of two new antigens with great potential application in the diagnosis of chronic Chagas disease.  相似文献   

8.

Background

Chagas disease is caused by the flagellate protozoan Trypanosoma cruzi (T. cruzi). It is endemic in Latin American countries outside the Caribbean. The current criterion for cure in the chronic phase of the disease is the negativization of at least two serological tests such as enzyme-linked immunosorbent assay (ELISA), indirect immunofluorescence assay (IIF) and indirect hemagglutination assay (IHA). The serological evolution of treated subjects with chronic T. cruzi infection is variable. Treatment failure is indicated by a positive parasitological and/or molecular test (persistence of parasitemia).

Objectives

To summarize the pattern of response to treatment of parasitological, molecular and serological tests performed during the follow-up of subjects with chronic T. cruzi infection.

Methods

Electronic searches in relevant databases and screening of citations of potentially eligible articles were accomplished. Organizations focusing on neglected infectious diseases were asked for help in identifying relevant studies.Included studies were randomized controlled trials (RCTs), quasi-RCTs, and cohort studies involving adults and children with chronic infection who received trypanocidal treatment (benznidazole or nifurtimox) and were followed over time. The assessment of risk of bias was performed separately for each study design. The Cochrane Collaboration’s tool and the guidelines developed by Hayden et al. were used. Two reviewers extracted all data independently. A third review author was consulted in case of discordant opinion.Additional analyses were defined in ad-hoc basis. Scatter plots for percentage of positive parasitological and molecular tests and for negative serological tests were developed by using the lowess curve technique. Heterogeneity was measured by I2.The protocol was registered in PROSPERO, an international prospective register of systematic review protocols (Registration Number CRD42012002162).

Results

Out of 2,136 citations screened, 54 studies (six RCTs and 48 cohort studies) were included. The smoothed curves for positive xenodiagnosis and positive polymerase chain reaction (PCR) were characterized by a sharp decrease at twelve month posttreatment. Afterwards, they reached 10–20% and 40% for xenodiagnosis and PCR, respectively. The smoothed curves for negative conventional serological tests increased up to 10% after 48 months of treatment. In the long-term, the rate of negativization was between 20% and 45%.The main sources of bias identified across cohort studies were the lack of control for confounding and attrition bias. In general, RCTs were judged as low risk of bias in all domains. The level of heterogeneity across included studies was moderate to high.Additional analysis were incomplete because of the limited availability of data. In this regard, the country of origin of study participants might affect the results of parasitological and molecular tests, while the level of risk of bias might affect serological outcomes. Subgroup analysis suggested that seronegativization occurs earlier in children compared to adults.

Conclusions

We acknowledge that there is a dynamic pattern of response based on parasitological, molecular and serological tests in subjects chronically infected with T. cruzi after treatment. Our findings suggest a trypanocidal effect in the long-term follow-up.Further research is needed to explore potential sources of heterogeneity and to conduct reliable subgroup analysis.  相似文献   

9.
A cross section of a human population (501 individuals) selected at random, and living in a Bolivian community, highly endemic for Chagas disease, was investigated combining together clinical, parasitological and molecular approaches. Conventional serology and polymerase chain reaction (PCR) indicated an active transmission of the infection, a high seroprevalence (43.3%) ranging from around 12% in < 5 years to 94.7% in > 45 years, and a high sensitivity (83.8%) and specificity of PCR. Abnormal ECG tracing was predominant in chagasic patients and was already present among individuals younger than 13 years. SAPA (shed acute phase antigen) recombinant protein and the synthetic peptide R-13 were used as antigens in ELISA tests. The reactivity of SAPA was strongly associated to Trypanosoma cruzi infection and independent of the age of the patients but was not suitable neither for universal serodiagnosis nor for discrimination of specific phases of Chagas infection. Anti-R-13 response was observed in 27.5% only in chagasic patients. Moreover, anti-R13 reactivity was associated with early infection and not to cardiac pathology. This result questioned previous studies, which considered the anti-R-13 response as a marker of chronic Chagas heart disease. The major clonets 20 and 39 (belonging to Trypanosoma cruzi I and T. cruzi II respectively) which circulate in equal proportions in vectors of the studied area, were identified in patients' blood by PCR. Clonet 39 was selected over clonet 20 in the circulation whatever the age of the patient. The only factor related to strain detected in patients' blood, was the anti-R-13 reactivity: 37% of the patients infected by clonet 39 (94 cases) had anti-R13 antibodies contrasting with only 6% of the patients without clonet 39 (16 cases).  相似文献   

10.
Chagas disease or American trypanosomiasis is, together with geohelminths, the neglected disease that causes more loss of years of healthy life due to disability in Latin America. Chagas disease, as determined by the factors and determinants, shows that different contexts require different actions, preventing new cases or reducing the burden of disease. Control strategies must combine two general courses of action including prevention of transmission to prevent the occurrence of new cases (these measures are cost effective), as well as opportune diagnosis and treatment of infected individuals in order to prevent the clinical evolution of the disease and to allow them to recuperate their health. All actions should be implemented as fully as possible and with an integrated way, to maximise the impact. Chagas disease cannot be eradicated due because of the demonstrated existence of infected wild triatomines in permanent contact with domestic cycles and it contributes to the occurrence of at least few new cases. However, it is possible to interrupt the transmission of Trypanosoma cruzi in a large territory and to eliminate Chagas disease as a public health problem with a dramatic reduction of burden of the disease.  相似文献   

11.
Clinical immunoassays often display suitable sensitivity but some lack of specificity or vice versa. As a trade-off between specificity improvement and sensitivity loss, biosensors were designed to perform indirect immunoassays with amperometric detection using tailor-made chimeric receptors to react with the analyte, specific anti-Trypanosoma cruzi immunoglobulin G (IgG). Recombinant chimeras were designed to favor their oriented covalent attachment. This allows the chimeras to properly expose their epitopes, to efficiently capture the analyte, and to withstand severe chemical treatment to reuse the biosensors. By further binding the secondary antibody, horseradish peroxidase-labeled anti-human IgG, in the presence of the soluble mediator and the enzyme substrate, a current that increased with the analyte concentration was measured. Biosensors using the chimeric constructions showed 100% specificity with samples that had revealed false-positive results when using other bioreceptors. A protein bearing a poly-Lys chain and thioredoxin as directing elements displayed the highest signal-to-noise ratio (P < 0.05). The limit of detection was 62 ng ml−1, which is eight times lower than that obtained with a currently used commercial Chagas enzyme-linked immunosorbent assay (ELISA) kit. Reusability of the biosensor was assessed. The signal was approximately 80% of the original one after performing 10 consecutive determinations.  相似文献   

12.
Diagnostic tests for veterinary surveillance programs should be efficient, easy to use and, possibly, economical. In this context, classic Enzyme linked ImmunoSorbent Assay (ELISA) remains the most common analytical platform employed for serological analyses. The analysis of pooled samples instead of individual ones is a common procedure that permits to certify, with one single test, entire herds as “disease-free”. However, diagnostic tests for pooled samples need to be particularly sensitive, especially when the levels of disease markers are low, as in the case of anti-BoHV1 antibodies in milk as markers of Infectious Bovine Rhinotracheitis (IBR) disease. The avidin-nucleic-acid-nanoassembly (ANANAS) is a novel kind of signal amplification platform for immunodiagnostics based on colloidal poly-avidin nanoparticles that, using model analytes, was shown to strongly increase ELISA test performance as compared to monomeric avidin. Here, for the first time, we applied the ANANAS reagent integration in a real diagnostic context. The monoclonal 1G10 anti-bovine IgG1 antibody was biotinylated and integrated with the ANANAS reagents for indirect IBR diagnosis from pooled milk mimicking tank samples from herds with IBR prevalence between 1 to 8%. The sensitivity and specificity of the ANANAS integrated method was compared to that of a classic test based on the same 1G10 antibody directly linked to horseradish peroxidase, and a commercial IDEXX kit recently introduced in the market. ANANAS integration increased by 5-fold the sensitivity of the 1G10 mAb-based conventional ELISA without loosing specificity. When compared to the commercial kit, the 1G10-ANANAS integrated method was capable to detect the presence of anti-BHV1 antibodies from bulk milk of gE antibody positive animals with 2-fold higher sensitivity and similar specificity. The results demonstrate the potentials of this new amplification technology, which permits improving current classic ELISA sensitivity limits without the need for new hardware investments.  相似文献   

13.

Background

The laboratory diagnosis of Chagas disease is challenging because the usefulness of different diagnostic tests will depend on the stage of the disease. Serology is the preferred method for patients in the chronic phase, whereas PCR can be successfully used to diagnose acute and congenital cases. Here we present data using a combination of three TaqMan PCR assays to detect T. cruzi DNA in clinical specimens.

Methods/Principal Findings

Included in the analysis were DNA extracted from 320 EDTA blood specimens, 18 heart tissue specimens, 6 umbilical cord blood specimens, 2 skin tissue specimens and 3 CSF specimens. For the blood specimens both whole blood and buffy coat fraction were analyzed. The specimens were from patients living in the USA, with suspected exposure to T. cruzi through organ transplantation, contact with triatomine bugs or laboratory accidents, and from immunosuppressed patients with suspected Chagas disease reactivation. Real-time PCR was successfully used to diagnose acute and Chagas disease reactivation in 20 patients, including one case of organ-transmitted infection and one congenital case. Analysis of buffy coat fractions of EDTA blood led to faster diagnosis in six of these patients compared to whole blood analysis. The three real-time PCR assays produced identical results for 94% of the specimens. The major reason for discrepant results was variable sensitivity among the assays, but two of the real-time PCR assays also produced four false positive results.

Conclusions/Significance

These data strongly indicate that at least two PCR assays with different performances should be combined to increase the accuracy. This evaluation also highlights the benefit of extracting DNA from the blood specimen''s buffy coat to increase the sensitivity of PCR analysis.  相似文献   

14.
Polymerase chain reaction (PCR) from bronchoalveolar lavage clinical samples (BAL) has been used to assist in the diagnosis of invasive aspergillosis. Several studies have been published regarding the utility of this test, although no systematic review of the literature has been performed to date. The objective of this systematic review was to evaluate the efficacy of PCR from BAL for the diagnosis of invasive aspergillosis in high risk patients. MEDLINE and LILACS databases (1980-2006) searches to identify articles related to PCR in diagnosis of invasive aspergillosis. For inclusion, the study had to report sufficient data to calculate sensitivity, specificity and diagnostic odds ratio of the PCR-based technique. Patients with proven and probably invasive aspergillosis were considered. Forty-five articles met our initial inclusion criteria of which 15 articles were selected. Combining the results from the different reports, the overall sensitivity and specificity values of PCR-based techniques were 79% and 94%, respectively. Contamination, specific primers and method of PCR were important variables that could complicate interpretation of these tests. The present study showed support for the clinical value of PCR from BAL for the diagnosis of invasive aspergillosis in patients with risk factors for this disease.  相似文献   

15.
IntroductionCongenital infection caused by Toxoplasma gondii can cause serious damage that can be diagnosed in utero or at birth, although most infants are asymptomatic at birth. Prenatal diagnosis of congenital toxoplasmosis considerably improves the prognosis and outcome for infected infants. For this reason, an assay for the quick, sensitive, and safe diagnosis of fetal toxoplasmosis is desirable.GoalTo systematically review the performance of polymerase chain reaction (PCR) analysis of the amniotic fluid of pregnant women with recent serological toxoplasmosis diagnoses for the diagnosis of fetal toxoplasmosis.MethodA systematic literature review was conducted via a search of electronic databases; the literature included primary studies of the diagnostic accuracy of PCR analysis of amniotic fluid from pregnant women who seroconverted during pregnancy. The PCR test was compared to a gold standard for diagnosis.ResultsA total of 1.269 summaries were obtained from the electronic database and reviewed, and 20 studies, comprising 4.171 samples, met the established inclusion criteria and were included in the review. The following results were obtained: studies about PCR assays for fetal toxoplasmosis are generally susceptible to bias; reports of the tests’ use lack critical information; the protocols varied among studies; the heterogeneity among studies was concentrated in the tests’ sensitivity; there was evidence that the sensitivity of the tests increases with time, as represented by the trimester; and there was more heterogeneity among studies in which there was more time between maternal diagnosis and fetal testing. The sensitivity of the method, if performed up to five weeks after maternal diagnosis, was 87% and specificity was 99%.ConclusionThe global sensitivity heterogeneity of the PCR test in this review was 66.5% (I2). The tests show low evidence of heterogeneity with a sensitivity of 87% and specificity of 99% when performed up to five weeks after maternal diagnosis. The test has a known performance and could be recommended for use up to five weeks after maternal diagnosis, when there is suspicion of fetal toxoplasmosis.  相似文献   

16.

Background

One of the most important drawbacks in visceral leishmaniasis (VL) population studies is the difficulty of diagnosing asymptomatic carriers. The aim of this study, conducted in an urban area in the Southeast of Brazil, was to evaluate the performance of serology to identify asymptomatic VL infection in participants selected from a cohort with a two-year follow-up period.

Methodology

Blood samples were collected in 2001 from 136 cohort participants (97 positive and 39 negatives, PCR/hybridization carried out in 1999). They were clinically evaluated and none had progressed to disease from their asymptomatic state. As controls, blood samples from 22 control individuals and 8 patients with kala-azar were collected. Two molecular biology techniques (reference tests) were performed: PCR with Leishmania-generic primer followed by hybridization using L. infantum probe, and PCR with specific primer to L. donovani complex. Plasma samples were tested by ELISA using three different antigens: L. infantum and L. amazonensis crude antigens, and rK39 recombinant protein. Accuracy of the serological tests was evaluated using sensitivity, specificity, likelihood ratio and ROC curve.

Findings

The presence of Leishmania was confirmed, by molecular techniques, in all kala-azar patients and in 117 (86%) of the 136 cohort participants. Kala-azar patients showed high reactivity in ELISAs, whereas asymptomatic individuals presented low reactivity against the antigens tested. When compared to molecular techniques, the L. amazonensis and L. infantum antigens showed higher sensitivity (49.6% and 41.0%, respectively) than rK39 (26.5%); however, the specificity of rK39 was higher (73.7%) than L. amazonensis (52.6%) and L. infantum antigens (36.8%). Moreover, there was low agreement among the different antigens used (kappa<0.10).

Conclusions

Serological tests were inaccurate for diagnosing asymptomatic infections compared to molecular methods; this could lead to misclassification bias in population studies. Therefore, studies which have used serological assays to estimate prevalence, to evaluate intervention programs or to identify risk factors for Leishmania infection, may have had their results compromised.  相似文献   

17.
ObjectiveTo evaluate diagnostic precision of two rapid diagnostic tests (RDT’s) on patients with chronic Chagas disease.MethodologyProspective study with the following inclusion criteria: subjects older than 3 years, signed informed consent. Exclusion criterion: subjects could not have previously received treatment for infection with T. cruzi. The study population were participants in a screening process undertaken in rural and urban zones of the department Boyacá, Colombia. Two RDT’s were performed to all participants: the Chagas Detect Plus InBios (CDP) and the Chagas Stat-Pak (CSP) and as a reference standard the ELISA Chagas III GrupoBios and the Chagas ELISA IgG+IgM I Vircell tests were used. In the case of discordant results between the two ELISA tests, an indirect immunofluorescence was done.ResultsThree hundred-five (305) subjects were included in the study (38 patients with leishmaniasis), of which 215 tested negative for T cruzi and 90 tested positive according to the reference standard. The sensitivity of the RDT’s were 100% (CI 95% 95.9–100), and the specificity of the CDP was 99.1% (CI 95% 96.6–99.8) and for CSP was 100% (CI 95% 98.3–100). The agreement of CDP was 99.5% and for CSP was 100% with Kappa values of (k = 99.1; CI 95% 92.6–99.8%) and (k = 100; CI 95% 94.3–100), respectively. RDT’s did not present cross-reactions with samples from patients who were positive for leishmaniasis.ConclusionsThe findings demonstrate excellent results from the RDT’s in terms of validity, safety, and reproducibility. The results obtained provide evidence for the recommendation for using these tests in a Colombian epidemiological context principally in endemic areas in which laboratory installations necessary to perform conventional tests are not available, or they are scarce and to help in diagnosing chronic Chagas disease in order to provide access to treatment as soon as possible.  相似文献   

18.
Antibody-based diagnosis of small ruminant lentiviruses (SRLVs) has been efficiently achieved using serum and milk, but not semen, for which polymerase chain reaction (PCR) has been proposed as a confirmatory technique. This work, involving 296 ovine (Ovis aries) and caprine (Capra hircus) semen donors, investigates whether seminal fluid (SF) can be reliably used in antibody-based SRLV diagnosis. First, a gold standard was established to assess the infection status and determine the sensitivity and specificity of three commercial enzyme-linked immunosorbent assays (ELISAs) in serum testing using Western blot and PCR as confirmatory tests. For SF testing, both gold standard and serum testing results were used as reference. The performance of SF testing was affected not only by the ELISA assay sensitivity (related to antigen spectrum) compared with that of the gold standard (as it occurred in serum testing) but also by SF sample quality and SF working dilution. Nonturbid SF samples, commonly collected in artificial insemination centers (AICs), were required. Compared with serum, SF testing had a decreased sensitivity in two of the ELISA assays (with original serum working dilutions ≤1/20 in serum testing) but reached a similar sensitivity (and specificity) in the assay designed to work at the highest serum dilution (1/500). A SF concentration of about 1/2 (250-fold that used in serum testing) was found optimal in this assay, yielding highly repeatable results that were in almost perfect agreement with those of serum testing (κ ± SE, 0.91 ± 0.81). Thus, SF ELISA can be reliably applied in antibody-based SRLV diagnosis. This information may be useful to control infection in AICs and animal and semen trade programs requiring health-certified quality of semen donors.  相似文献   

19.
To establish a definite diagnosis for pulmonary hydatid disease, combination of radiology and serology is useful. In this study, 19 preoperative sera from patients with surgically confirmed pulmonary hydatidosis, 40 sera from patients with other parasitosis and pulmonary diseases, and 20 sera from healthy donors were evaluated using 4 different serological tests, i.e., the commercial ELISA (ELISA-kit) test, the ELISA (ELISA-lab) test prepared in our laboratory, the commercial indirect hemagglutination assay kit (IHA-kit) test, and the IHA test using sensitized sheep red blood cells with tannic acid (IHA-TA). The ELISA-kit was the most sensitive (84.2%) and the most specific test (100.0%). The ELISA-kit also demonstrated the highest positive (100.0%) and negative (95.2%) predictive values. The sensitivity of the ELISA-lab test, that we prepared, was found to be 73.6%, whereas the IHA-kit test and the IHA-TA test were found to be 73.6% and 68.4%, respectively. The specificity of these tests was 96.6%, 98.3%, and 83.3%, respectively. When all 4 tests were assessed together, it was found that the sensitivity had risen to 94.7%. When the ELISA-kit was assessed with the IHA-kit and IHA-TA together, it was found that the sensitivity was 89.5% and 84.2%, respectively. Likewise, the combination of the ELISA-lab and IHA-kit or IHA-TA allowed us to achieve a sensitivity of 84.2% in cases of pulmonary echinococcosis. In conclusion, the diagnosis would be imminent if least 2 tests were applied together.  相似文献   

20.

Background

In recent decades, sporadic cases and outbreaks in humans of West Nile virus (WNV) infection have increased. Serological diagnosis of WNV infection can be performed by enzyme-linked immunosorbent assay (ELISA), immunofluorescence assay (IFA) neutralization test (NT) and by hemagglutination-inhibition assay. The aim of this study is to collect updated information regarding the performance accuracy of WNV serological diagnostics.

Methodology/Principal findings

In 2011, the European Network for the Diagnostics of Imported Viral Diseases-Collaborative Laboratory Response Network (ENIVD-CLRN) organized the second external quality assurance (EQA) study for the serological diagnosis of WNV infection. A serum panel of 13 samples (included sera reactive against WNV, plus specificity and negative controls) was sent to 48 laboratories involved in WNV diagnostics. Forty-seven of 48 laboratories from 30 countries participated in the study. Eight laboratories achieved 100% of concurrent and correct results. The main obstacle in other laboratories to achieving similar performances was the cross-reactivity of antibodies amongst heterologous flaviviruses. No differences were observed in performances of in-house and commercial test used by the laboratories. IFA was significantly more specific compared to ELISA in detecting IgG antibodies. The overall analytical sensitivity and specificity of diagnostic tests for IgM detection were 50% and 95%, respectively. In comparison, the overall sensitivity and specificity of diagnostic tests for IgG detection were 86% and 69%, respectively.

Conclusions/Significance

This EQA study demonstrates that there is still need to improve serological tests for WNV diagnosis. The low sensitivity of IgM detection suggests that there is a risk of overlooking WNV acute infections, whereas the low specificity for IgG detection demonstrates a high level of cross-reactivity with heterologous flaviviruses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号